BPG is committed to discovery and dissemination of knowledge
Retrospective Cohort Study
Copyright: ©Author(s) 2026. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial (CC BY-NC 4.0) license. No commercial re-use. See permissions. Published by Baishideng Publishing Group Inc.
World J Radiol. Apr 28, 2026; 18(4): 119851
Published online Apr 28, 2026. doi: 10.4329/wjr.v18.i4.119851
Artificial intelligence-based lung nodule detection for pulmonary arteriovenous fistulas on chest computed tomography
Kimei Azama, Nanae Tsuchiya, Shun Toyosato, Koji Yonemoto, Akihiro Nishie
Kimei Azama, Nanae Tsuchiya, Shun Toyosato, Akihiro Nishie, Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Ginowan 9012720, Okinawa, Japan
Koji Yonemoto, Department of Biostatistics, School of Health Sciences, Faculty of Medicine, University of the Ryukyus, Ginowan 9012720, Okinawa, Japan
Author contributions: Azama K drafted the manuscript and collected the data; Azama K and Tsuchiya N conceived and designed the study; Azama K, Tsuchiya N, and Toyosato S performed the image evaluation; Azama K and Tsuchiya N analyzed and interpreted the data; Yonemoto K verified the statistical methods and reviewed the statistical analyses; Tsuchiya N and Nishie A critically revised the manuscript for important intellectual content; and all authors approved the final version of the manuscript.
Institutional review board statement: This study was approved by the Medical Ethics Committee of University of the Ryukyus, approval No. 1938.
Informed consent statement: The requirement for informed consent was waived due to the retrospective nature of the study.
Conflict-of-interest statement: All the authors report no relevant conflicts of interest for this article.
STROBE statement: The authors have read the STROBE Statement-checklist of items, and the manuscript was prepared and revised according to the STROBE Statement-checklist of items.
Data sharing statement: The data that support the findings of this study are available from the corresponding author upon reasonable request. Due to institutional and ethical restrictions, the data are not publicly available.
Corresponding author: Kimei Azama, MD, PhD, Assistant Professor, Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, Kiyuna 1076, Ginowan 9012720, Okinawa, Japan. okinawan@iemik.onmicrosoft.com
Received: February 9, 2026
Revised: March 5, 2026
Accepted: April 7, 2026
Published online: April 28, 2026
Processing time: 75 Days and 21.7 Hours
Core Tip

Core Tip: Pulmonary arteriovenous fistulas (PAVFs) are vascular lesions, frequently detected on chest computed tomography. This study demonstrated that an artificial intelligence-based computer-aided detection (CAD) system originally developed for pulmonary nodule detection identified PAVFs with a detection rate of 65% and provided reliable quantitative measurements of lesion length. Although the detection performance was lower than that previously reported for pulmonary nodules, CAD-based analysis showed strong agreement with manual measurements. These findings suggest that lung nodule CAD systems may have broader clinical utility beyond their original purpose, including a potential role as adjunct tools for the opportunistic detection and longitudinal follow-up of PAVFs.