Clinical and Translational Research
Copyright ©The Author(s) 2020.
World J Clin Cases. Aug 26, 2020; 8(16): 3431-3439
Published online Aug 26, 2020. doi: 10.12998/wjcc.v8.i16.3431
Table 1 McNemar's test results of degeneration visualized using molybdenum target X-ray photography and conventional X-ray examination (n = 19)
Molybdenum target inspection (No.)
ObviousUnobviousaP
Plain X-ray (No.)Obvious1200.031
Unobvious61
Table 2 Measured height of space between degenerative vertebral segments in different plain X-ray images
mean ± SD1 (mm)Observer 1Observer 2Observer 3Observer 4ICC
Needle puncture model (n = 9)X-ray2.0 ± 0.71.8 ± 0.52.3 ± 0.21.6 ± 0.40.41
Molybdenum1.7 ± 0.21.9 ± 0.21.9 ± 0.31.8 ± 0.10.81
Endplate-injured model (n = 10)X-ray1.7 ± 0.32.2 ± 0.52.6 ± 0.31.8 ± 0.10.35
Molybdenum2.1 ± 0.11.9 ± 0.32.1 ± 0.12.0 ± 0.20.92