Copyright
©The Author(s) 2024.
World J Clin Cases. Jul 16, 2024; 12(20): 4108-4120
Published online Jul 16, 2024. doi: 10.12998/wjcc.v12.i20.4108
Published online Jul 16, 2024. doi: 10.12998/wjcc.v12.i20.4108
Table 1 Material property settings
Material name | Elastic modulus (MPa) | Poisson's ratio |
Trabecular bone | 200 | 0.2 |
Cortical bone | 12000 | 0.3 |
Pedicle screw | 3500 | 0.25 |
Intervertebral disc | 3.4 | 0.39 |
Screw-rod system | 120000 | 0.33 |
Table 2 Pull-out strength of pedicle screws (unit: N)
TSA | Pull-out resistance | Maximum vertebral stress |
0 degrees | 132.8 ± 4.99 | 2.0058 ± 0.0031 |
7 degrees | 139.6 ± 5.24 | 2.001 ± 0.0029 |
10 degrees | 145.4 ± 6.09 | 2.0015 ± 0.0058 |
17 degrees | 149.8 ± 6.72 | 2.0066 ± 0.0075 |
F | 314.683 | 1.928 |
P value | 0.001 | 0.182 |
Table 3 Maximum stress calculations for pedicle screws (unit: MPa)
TSA | Extension | Flexion | Right lateral bending | Left lateral bending | Right rotation | Left rotation |
0 degrees | 437.85 ± 11.72 | 335.1 ± 9.85 | 433.64 ± 10.15 | 612.31 ± 22.52 | 657.5 ± 44.84 | 582.2 ± 47.57 |
17 degrees | 626.18 ± 44.45 | 242.8 ± 21.52 | 648.5 ± 83.31 | 488.62 ± 36.67 | 551.12 ± 24.01 | 548.4 ± 46.03 |
F | 1313.129 | 196.715 | 1875.31 | 546.879 | 3557.963 | 1261.657 |
P value | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Table 4 Load-displacement ratio for pedicle screws (unit: N/mm)
TSA | Extension | Flexion | Right lateral bending | Left lateral bending | Right rotation | Left rotation |
0 degrees | 2740.93 ± 165.32 | 392.80 ± 22.71 | 483.01 ± 29.98 | 394.84 ± 20.03 | 351.67 ± 20.84 | 396.13 ± 23.69 |
17 degrees | 2165.44 ± 131.12 | 353.29 ± 20.36 | 527.13 ± 33.77 | 425.08 ± 24.35 | 364.43 ± 19.14 | 428.47 ± 27.76 |
F | 124.963 | 33.72 | 72.107 | 6.14 | 4.986 | 7.093 |
P value | 0.000 | 0.000 | 0.000 | 0.011 | 0.028 | 0.001 |
Table 5 Maximum stress in the vertebral body (unit: MPa)
TSA | Extension | Flexion | Right lateral bending | Left lateral bending | Right rotation | Left rotation |
0 degrees | 68.585 ± 4.41 | 77.245 ± 5.21 | 69.775 ± 4.19 | 78.91 ± 6.05 | 72.192 ± 4.22 | 68.45 ± 4.09 |
17 degrees | 39.079 ± 2.40 | 55.681 ± 3.89 | 65.348 ± 4.09 | 72.734 ± 5.02 | 66.227 ± 4.31 | 45.756 ± 3.19 |
F | 628.454 | 197.455 | 78.021 | 48.819 | 14.763 | 368.721 |
P value | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 |
Table 6 Vertebral load displacement ratio (unit: N/mm)
TSA | Extension | Flexion | Right lateral bending | Left lateral bending | Right rotation | Left rotation |
0 degrees | 1827.29 ± 114.78 | 261.87 ± 16.01 | 318.39 ± 20.71 | 307.10 ± 21.09 | 273.52 ± 18.13 | 264.10 ± 17.33 |
17 degrees | 1443.65 ± 83.75 | 274.79 ± 18.53 | 344.18 ± 27.18 | 327.74 ± 23.35 | 283.45 ± 17.06 | 281.93 ± 21.99 |
F | 134.605 | 6.144 | 229.409 | 97.584 | 3.775 | 8.134 |
P value | 0.000 | 0.012 | 0.000 | 0.000 | 0.027 | 0.001 |
- Citation: Jiang JH, Zhao CM, Zhang J, Xu RM, Chen L. Biomechanical effects of posterior lumbar interbody fusion with vertical placement of pedicle screws compared to traditional placement. World J Clin Cases 2024; 12(20): 4108-4120
- URL: https://www.wjgnet.com/2307-8960/full/v12/i20/4108.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v12.i20.4108