Copyright
©The Author(s) 2022.
World J Clin Cases. Aug 26, 2022; 10(24): 8587-8598
Published online Aug 26, 2022. doi: 10.12998/wjcc.v10.i24.8587
Published online Aug 26, 2022. doi: 10.12998/wjcc.v10.i24.8587
Table 1 Interreader reproducibility of measurement of diffusion parameters of thyroid nodules
| Diffusion parameter | ICC | 95%CI |
| Mono-exponential | ||
| ADC(0 and 1000) | 0.944 | (0.852, 0.979) |
| ADC(0 to 1000) | 0.938 | (0.898, 0.962) |
| ADC(0 and 2000) | 0.904 | (0.844, 0.941) |
| ADC(0 to 2000) | 0.942 | (0.905, 0.962) |
| Biexponential | ||
| D | 0.949 | (0.921, 0.967) |
| D* | 0.935 | (0.900, 0.958) |
| f | 0.897 | (0.844, 0.933) |
| stretched exponential | ||
| DDC | 0.994 | (0.990, 0.996) |
| α | 0.973 | (0.958, 0.983) |
| Kurtosis DWI | ||
| Dapp | 0.787 | (0.685, 0.859) |
| Kapp | 0.855 | (0.782, 0.905) |
Table 2 Comparison of diffusion parameters between benign and malignant thyroid nodules
| Diffusion parameter | Benign nodules | Malignant nodules | P value |
| Mono-exponential | |||
| ADC(0 and 1000) | 1.85 ± 0.24 | 1.29 ± 0.27 | < 0.01 |
| ADC(0 to 1000) | 1.79 ± 0.021 | 1.19 ± 0.23 | < 0.01 |
| ADC(0 and 2000) | 1.35 ± 0.15 | 0.95 ± 0.15 | < 0.01 |
| ADC(0 to 2000) | 1.41 ± 0.15 | 0.95 ± 0.15 | < 0.01 |
| Biexponential | |||
| D | 1.34 ± 0.41 | 0.89 ± 0.26 | < 0.01 |
| D* | 22.08 ± 18.53 | 26.09 ± 20.87 | > 0.05 |
| f | 0.38 ± 0.19 | 0.30 ± 0.14 | < 0.01 |
| Stretched exponential | |||
| DDC | 2.15 ± 0.62 | 1.45 ± 0.51 | < 0.01 |
| α | 0.78 ± 0.19 | 0.67 ± 0.19 | < 0.01 |
| Kurtosis DWI | |||
| Dapp | 2.88 ± 0.73 | 2.11 ± 0.67 | < 0.01 |
| Kapp | 0.57 ± 0.12 | 0.85 ± 0.19 | < 0.01 |
Table 3 Diagnostic performance of diffusion parameters for differentiating malignant thyroid nodules from benign thyroid nodules
| Diffusion parameter | AUC | Cut-off value | Sensitivity, % | Specificity, % | Youden index | P value |
| Mono-exponential | ||||||
| ADC(0 and 1000) | 0.879 | 1.6 | 64.5 | 100.0 | 0.645 | Ref. |
| ADC(0 and 2000) | 0.874 | 1.1 | 79.0 | 88.2 | 0.672 | 0.94 |
| ADC(0 to 1000) | 0.882 | 1.5 | 72.6 | 100.0 | 0.726 | 0.94 |
| ADC(0 to 2000) | 0.878 | 1.1 | 77.4 | 88.2 | 0.656 | 0.99 |
| Biexponential | ||||||
| D | 0.861 | 1.1 | 71.0 | 94.1 | 0.651 | 0.76 |
| D* | 0.643 | 22.2 | 88.2 | 56.5 | 0.447 | < 0.01 |
| f | 0.709 | 0.37 | 46.8 | 100.0 | 0.468 | < 0.05 |
| Stretched exponential | ||||||
| DDC | 0.841 | 2.0 | 59.7 | 100.0 | 0.597 | 0.53 |
| α | 0.748 | 0.73 | 62.9 | 88.2 | 0.511 | < 0.05 |
| Kurtosis DWI | ||||||
| Dapp | 0.815 | 2.6 | 61.3 | 88.2 | 0.495 | 0.33 |
| Kapp | 0.889 | 0.65 | 100.0 | 74.2 | 0.742 | 0.84 |
- Citation: Zhu X, Wang J, Wang YC, Zhu ZF, Tang J, Wen XW, Fang Y, Han J. Quantitative differentiation of malignant and benign thyroid nodules with multi-parameter diffusion-weighted imaging. World J Clin Cases 2022; 10(24): 8587-8598
- URL: https://www.wjgnet.com/2307-8960/full/v10/i24/8587.htm
- DOI: https://dx.doi.org/10.12998/wjcc.v10.i24.8587