Case Report Open Access
Copyright ©The Author(s) 2016. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Clin Cases. Aug 16, 2016; 4(8): 229-232
Published online Aug 16, 2016. doi: 10.12998/wjcc.v4.i8.229
Extraordinary sneeze: Spontaneous transmaxillary-transnasal discharge of a migrated dental implant
Pasquale Procacci, Daniele De Santis, Dario Bertossi, Massimo Albanese, Cristina Plotegher, Giovanni Zanette, Alessia Pardo, Pier Francesco Nocini, Section of Oral and Maxillofacial Surgery, Department of Surgery, University of Verona, 1037134 Verona, Italy
Author contributions: All authors contributed to this paper.
Institutional review board statement: The present paper was reviewed and approved by the University of Verona Institutional Review Board.
Informed consent statement: All person (n°1 patient) involved in the present paper gave their informed consent to clinical case publication.
Conflict-of-interest statement: There is not any conflict-of-interest in the present paper.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Pasquale Procacci, MD, Assistant Professor, Section of Oral and Maxillofacial Surgery, Department of Surgery, University of Verona, Policlinico “Giovanni Battista Rossi”, Piazzale Ludovico Antonio Scuro n°10, 1037134 Verona, Italy. pasquale.procacci@univr.it
Telephone: +39-04-58124251 Fax: +39-04-58027437
Received: March 28, 2016
Peer-review started: March 29, 2016
First decision: May 16, 2016
Revised: May 26, 2016
Accepted: June 1, 2016
Article in press: June 3, 2016
Published online: August 16, 2016
Processing time: 136 Days and 23.5 Hours

Abstract

This case report describes an extraordinary case of the spontaneous transmaxillary-transnasal discharge of a dental implant, which occurred during a sneeze. The patient was complained of symptoms of acute sinusitis. She underwent a computed tomography scan that revealed a dental implant dislocated in the maxillary sinus. Medical treatment based on antibiotics and mucolytics was administered to the patient in order to prepare her for endoscopic endonasal surgery. The implant was spontaneously discharged two days after during a sneeze. Mucociliary clearance in combination with a local osteolytic inflammatory process and mucolytics therapy are the likely causes of this unusual discharge.

Key Words: Complications; Dental implant; Acute sinusitis; Implant surgery

Core tip: Iatrogenic dislocation of dental implants into paranasal sinuses is not a rare pathological finding. Dental implants dislocation are commonly related to a wrong operating procedure or diagnostic clinical planning. Functional endoscopic sinus surgery has been widely described as the first option to remove foreign bodies from the paranasal sinuses, while the Caldwell-Luc approach to the maxillary sinuses still represents an option if the patients wants to avoid general anesthesia. Up-today just one case of spontaneous nasal discharge was reported in the literature. Therefore this case report describes a really uncommon clinical finding.



INTRODUCTION

Implant-supported prosthetic rehabilitation represents one of the most common procedures in dental clinical practice[1]. In surgical dental treatment that includes the posterior maxillary region, such as implant placement or impacted third molar extraction, the maxillary sinus should be taken into account because of its anatomical position[2,3]. Implant displacement into paranasal sinuses has been reported frequently in the literature[4-9]. According to the associated complications (implant displacement, implant displacement with or without reactive sinusitis and/or with or without associated oro-antral communication), such approaches as functional endoscopic sinused surgery (FESS), intraoral approach to the sinus, or FESS associated with an intraoral approach could be considered[10]. To the authors’ knowledge, this is the second report of a migrated dental implant spontaneous transnasal-transmaxillary discharge[11].

CASE REPORT

A 63-year-old woman was referred to our Department complaining of pain in the right cheek, malar rubor and edema, fever and nasal purulent discharge. Symptoms and signs appeared one week before her first visit. When the patient visited her private dentist with those symptoms, he promptly performed a radiological examination. The panoramic radiography revealed that an endosseous dental implant previously located at the posterior aspect of the right upper maxillary alveolar ridge had disappeared (Figure 1). On her arrival in our department, the patient immediately underwent a computed tomography scan which revealed that the dental implant was located inside the right maxillary sinus. The anterior aspect of the implant was completely inside the maxillary sinus while the posterior part was positioned throughout the osteomeatal complex. A massive right odontogenic sinusitis with ethmoid involvement was noticed (Figures 2 and 3). The clinical examination did not show any kind of oroantral communication at the superior aspect of the right maxillary ridge and the implant-supported prosthesis was stable without evidence of any kind of pathological signs. An endoscopic endonasal removal of the implant was then planned. A preoperative medical treatment [Ciprofloxacin (500 mg) and Acetylcysteine (600 mg)] twice a day for 7 d was administered in order to prepare her for surgery. Unexpectedly, 2 d after she reported that she had discharged the dental implant in the early morning during a sneeze (Figure 4). No bleeding took place. Surgery was then cancelled and the patient completed her medical treatment. Signs and symptoms disappeared without any kind of late complications within 7 d.

Figure 1
Figure 1 The preoperative panoramic radiography showed an unknown disappearance of an upper endosseous dental implant previously located in the posterior aspect of the right upper maxilla.
Figure 2
Figure 2 Coronal computed tomography scan clearly revealed the dental implant located in the upper third of the maxillary sinus. Acute maxillary sinusitis and ethmoiditis are evident.
Figure 3
Figure 3 Axial computed tomography scan allowed to analyze the exact position of the implant between the maxillary sinus interiorly and the osteomeatal complex posteriorly.
Figure 4
Figure 4 The sneezed implant. The prosthetic abutment is still engaged to the dental implant.
DISCUSSION

Foreign body dislocation in the paranasal sinuses is a common event[12-14]. The presence of a foreign body inside a paranasal sinus often causes an acute inflammatory reaction of the Schneider membrane with a possible consequent obstruction of the sinus ostium. The occlusion of the osteomeatal complex and the edema of the sinusal membrane could lead to a severe alteration of the mucociliary function and, as a direct complication, an acute or recurrent sinusitis[15]. When foreign body displacement occurs, it has to be removed in order to avoid sinus pathology[10,12]. Although several different approaches to remove a foreign body from the maxillary sinus have been described, all of those should be associated with preoperative and postoperative antibiotic, mucolytics and corticosteroid treatment. The first aim of the medical therapy is to reduce the edema of the sinonasal mucosa and to limit the infection.

In the present case the patient underwent preoperative medical therapy that probably stimulated the reactivation of the mucociliary function of the maxillary sinus with a consequent dislocation of the migrated dental implant from the maxillary sinus to the osteomeatal complex. The dental implant then acted like a trigger causing subsequent multiple sneezing and the final extraordinary transnasal discharge of the foreign body.

COMMENTS
Case characteristics

The paper describes an extraordinary case of an ectopic implant spontaneously discharged during a sneeze.

Clinical diagnosis

The case describes an acute maxillary sinusitis due to a dislocated dental implants into maxillary sinus.

Differential diagnosis

Maxillary sinusitis vs rhinosinusitis.

Imaging diagnosis

Computed tomography scans clearly describe the position of the ectopic implant located between the maxillary ostium and the medial meatus.

Pathological diagnosis

Malar rubor and malar oedema associated with severe nasal discharge and nasal dripping allowed to make diagnosis of acute maxillary sinusitis.

Treatment

The patients was candidated to functional endoscopic sinuses surgery in order to remove the foreign body but immediately before the surgical procedure she discharge the ectopic dental implant.

Related reports

Please provide other contents related to the case report to help readers better understand the present case.

Term explanation

To the authors’ knowledge, this is the second report of a migrated dental implant spontaneous transnasal-transmaxillary discharge.

Experiences and lessons

The present case showed clearly how competent could be the mucociliary clearance and helps to understand that the combined antibiotic and mucolytic therapy is always advisable before surgery.

Peer-review

This case report describes an extraordinary case of the spontaneous transmaxillary-transnasal discharge of a dental implant. The implant was spontaneously discharged 2 d after during a sneeze. It is interesting and meaningfull.

Footnotes

Manuscript source: Invited manuscript

Specialty type: Medicine

Country of origin: Italy

Peer-review report classification

Grade A (Excellent): A

Grade B (Very good): 0

Grade C (Good): C

Grade D (Fair): 0

Grade E (Poor): 0

P- Reviewer: Gürel P, Liang ZQ S- Editor: Ji FF L- Editor: A E- Editor: Zhang FF

References
1.  Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132.  [PubMed]  [DOI]  [Cited in This Article: ]
2.  Grandini SA, Barros VM, Salata LA, Rosa AL, Soares UN. Complications in exodontia--accidental dislodgment to adjacent anatomical areas. Braz Dent J. 1993;3:103-112.  [PubMed]  [DOI]  [Cited in This Article: ]
3.  Nocini PF, De Santis D, Morandini B, Procacci P. A dental implant in the infratemporal fossa: case report. Int J Oral Maxillofac Implants. 2013;28:e195-e197.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 5]  [Cited by in F6Publishing: 4]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
4.  González-García A, González-García J, Diniz-Freitas M, García-García A, Bullón P. Accidental displacement and migration of endosseous implants into adjacent craniofacial structures: a review and update. Med Oral Patol Oral Cir Bucal. 2012;17:e769-e774.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 44]  [Cited by in F6Publishing: 45]  [Article Influence: 3.8]  [Reference Citation Analysis (0)]
5.  Connolly AA, White P. How I do it: transantral endoscopic removal of maxillary sinus foreign body. J Otolaryngol. 1995;24:73-74.  [PubMed]  [DOI]  [Cited in This Article: ]
6.  Galindo P, Sánchez-Fernández E, Avila G, Cutando A, Fernandez JE. Migration of implants into the maxillary sinus: two clinical cases. Int J Oral Maxillofac Implants. 2005;20:291-295.  [PubMed]  [DOI]  [Cited in This Article: ]
7.  Kitamura A. Removal of a migrated dental implant from a maxillary sinus by transnasal endoscopy. Br J Oral Maxillofac Surg. 2007;45:410-411.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 49]  [Cited by in F6Publishing: 39]  [Article Influence: 2.2]  [Reference Citation Analysis (0)]
8.  Haben CM, Balys R, Frenkiel S. Dental implant migration into the ethmoid sinus. J Otolaryngol. 2003;32:342-344.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 35]  [Cited by in F6Publishing: 36]  [Article Influence: 1.8]  [Reference Citation Analysis (0)]
9.  Felisati G, Lozza P, Chiapasco M, Borloni R. Endoscopic removal of an unusual foreign body in the sphenoid sinus: an oral implant. Clin Oral Implants Res. 2007;18:776-780.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 65]  [Cited by in F6Publishing: 66]  [Article Influence: 3.9]  [Reference Citation Analysis (0)]
10.  Chiapasco M, Felisati G, Maccari A, Borloni R, Gatti F, Di Leo F. The management of complications following displacement of oral implants in the paranasal sinuses: a multicenter clinical report and proposed treatment protocols. Int J Oral Maxillofac Surg. 2009;38:1273-1278.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 103]  [Cited by in F6Publishing: 110]  [Article Influence: 7.3]  [Reference Citation Analysis (0)]
11.  van de Loo S, Kessler P, Lethaus B. Spontaneous transmaxillary-transnasal implant loss: a case report. Implant Dent. 2013;22:117-119.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 5]  [Cited by in F6Publishing: 5]  [Article Influence: 0.5]  [Reference Citation Analysis (0)]
12.  Sgaramella N, Tartaro G, D’Amato S, Santagata M, Colella G. Displacement of Dental Implants Into the Maxillary Sinus: A Retrospective Study of Twenty-One Patients. Clin Implant Dent Relat Res. 2016;18:62-72.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 21]  [Cited by in F6Publishing: 23]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
13.  Kharel Sitaula R, Gautam V, Kc K, Shah DN. Impacted iron nail in the orbit and maxillary sinus through a corneo-scleral perforation: a case report. Nepal J Ophthalmol. 2013;5:268-271.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 2]  [Cited by in F6Publishing: 2]  [Article Influence: 0.2]  [Reference Citation Analysis (0)]
14.  Sahin YF, Muderris T, Bercin S, Sevil E, Kırıs M. Chronic maxillary sinusitis associated with an unusual foreign body: a case report. Case Rep Otolaryngol. 2012;2012:903714.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 10]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
15.  Feng L, Li H, E LL, Li CJ, Ding Y. Pathological changes in the maxillary sinus mucosae of patients with recurrent odontogenic maxillary sinusitis. Pak J Med Sci. 2014;30:972-975.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1]  [Cited by in F6Publishing: 1]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]