Copyright
©The Author(s) 2025.
World J Orthop. Mar 18, 2025; 16(3): 103955
Published online Mar 18, 2025. doi: 10.5312/wjo.v16.i3.103955
Published online Mar 18, 2025. doi: 10.5312/wjo.v16.i3.103955
Table 1 Comparing intraoperative imaging saved for patients who returned to theatre within 90 days due to screw malplacement vs those who did not
Number of patients who returned within 90 days due to screw malplacement | Number of patients who did not return within 90 days for screw malplacement | Total | |
AP and lateral intraoperative imaging saved | 13 | 714 | 727 |
Only lateral intraoperative imaging saved | 21 | 464 | 485 |
Only AP intraoperative imaging saved | 1 | 47 | 48 |
No intraoperative imaging available | 2 | 73 | 75 |
Total | 37 | 1298 | 1335 |
- Citation: Sherif R, Spence EC, Smith J, McCarthy MJH. Intraoperative imaging adequacy and its impact on unplanned return-to-theatre rates in pedicle screw instrumentation. World J Orthop 2025; 16(3): 103955
- URL: https://www.wjgnet.com/2218-5836/full/v16/i3/103955.htm
- DOI: https://dx.doi.org/10.5312/wjo.v16.i3.103955