Copyright
©The Author(s) 2025.
World J Gastroenterol. Aug 28, 2025; 31(32): 110573
Published online Aug 28, 2025. doi: 10.3748/wjg.v31.i32.110573
Published online Aug 28, 2025. doi: 10.3748/wjg.v31.i32.110573
Table 1 Dual-layer spectral computed tomography parameters
Scan parameters and contrast agent injection protocol | Details |
Scan parameters | |
Range | Diaphragmatic dome to the inferior pubic symphysis |
Tube voltage (kV) | 120 |
Tube current | Automatic tube current modulation |
Detector collimation (mm) | 64 × 0.625 |
Gantry rotation speed (second) | 0.4 |
Pitch | 1.0 |
Contrast agent | |
Concentration (mg/mL) | 350 |
Dose (mL/kg) | 1.5 |
Rate (mL/s) | 3.0 |
Monitoring | |
Monitoring method | Bolus tracking |
Monitoring level | Abdominal aorta |
Monitoring threshold (HU) | 150 |
Scan phases | Arterial phase, venous phase (delayed by 40 seconds) |
Table 2 Patient demographic characteristics
Characteristic | Percentage/cohort details |
Sex, n (%) | |
Male | 98 (62.4) |
Female | 59 (37.6) |
Age (mean ± SD, year) | 63.5 ± 12.1 |
Pathological stage, n (%) | |
T1 | 14 (8.9) |
T2 | 17 (10.8) |
T3 | 118 (75.2) |
T4 | 8 (5.1) |
Differentiation grade, n (%) | |
G1 | 9 (5.7) |
G2 | 142 (90.4) |
G3 | 6 (3.8) |
Tumor location | |
Rectum | 87 (55.4) |
Sigmoid colon | 31 (19.7) |
Descending colon | 11 (7.0) |
Splenic flexure | 1 (0.6) |
Transverse colon | 7 (4.5) |
Hepatic flexure | 1 (0.6) |
Ascending colon | 19 (12.1) |
Table 3 Subjective and objective image quality assessments of 40-70 keV virtual monoenergetic images and polyenergetic images in colorectal cancer evaluation (n = 157)
Subjective/objective | PEIs | 40 keV VMIs | 50 keV VMIs | 60 keV VMIs | 70 keV VMIs | Z value | P value |
Noise | 8.53 ± 2.90 | 8.17 ± 3.63 | 7.27 ± 3.18 | 6.83 ± 2.73 | 6.57 ± 2.58 | 74.521 | < 0.001 |
SNR | 8.41 ± 2.45 | 18.13 ± 7.09 | 14.81 ± 5.09 | 12.60 ± 4.05 | 10.73 ± 3.26 | 427.420 | < 0.001 |
CNR | 23.09 ± 8.95 | 45.69 ± 22.76 | 37.85 ± 18.12 | 31.58 ± 13.60 | 27.89 ± 12.11 | 275.540 | < 0.001 |
Subjective scores | 3.97 ± 0.42 | 4.88 ± 0.33 | 4.85 ± 0.36 | 4.69 ± 0.50 | 4.11 ± 0.49 | 376.086 | < 0.001 |
Table 4 Intergroup comparisons of subjective and objective image quality parameters for 40-70 keV virtual monoenergetic images and polyenergetic images in colorectal cancer evaluation (n = 157)
Subjective/objective | PEIs | 40 keV VMIs | 50 keV VMIs | 60 keV VMIs | 70 keV VMIs | |
Noise | PEI | - | 0.673 | < 0.001 | < 0.001 | < 0.001 |
40 keV VMIs | - | - | 0.054 | < 0.001 | < 0.001 | |
50 keV VMIs | - | - | - | 0.873 | 0.075 | |
60 keV VMIs | - | - | - | - | 1.000 | |
70 keV VMIs | - | - | - | - | - | |
SNR | PEIs | - | < 0.001 | < 0.001 | < 0.001 | < 0.001 |
40 keV VMIs | - | - | < 0.001 | < 0.001 | < 0.001 | |
50 keV VMIs | - | - | - | < 0.001 | < 0.001 | |
60 keV VMIs | - | - | - | - | < 0.001 | |
70 keV VMIs | - | - | - | - | - | |
CNR | PEIs | - | < 0.001 | < 0.001 | < 0.001 | < 0.001 |
40 keV VMIs | - | - | 0.002 | < 0.001 | < 0.001 | |
50 keV VMIs | - | - | - | 0.001 | < 0.001 | |
60 keV VMIs | - | - | - | - | < 0.001 | |
70 keV VMIs | - | - | - | - | - | |
Subjective scores | PEIs | - | < 0.001 | < 0.001 | < 0.001 | 0.376 |
40 keV VMIs | - | - | 1.000 | 0.033 | < 0.001 | |
50 keV VMIs | - | - | - | 0.120 | < 0.001 | |
60 keV VMIs | - | - | - | - | < 0.001 | |
70 keV VMIs | - | - | - | - | - |
Table 5 Interobserver agreement analysis of subjective quality scores between two radiologists for 40-70 keV virtual monoenergetic images and polyenergetic images (n = 157)
Subjective quality scores | Doctor B | ||||||
3 | 4 | 5 | κ | P value | |||
Doctor A | PEIs | 3 | 14 | 0 | 0 | 0.913 | < 0.001 |
4 | 2 | 130 | 2 | ||||
5 | 0 | 0 | 9 | ||||
40 keV VMIs | 3 | 0 | 0 | 0 | 0.812 | < 0.001 | |
4 | 0 | 15 | 2 | ||||
5 | 0 | 4 | 136 | ||||
50 keV VMIs | 3 | 0 | 0 | 0 | 0.813 | < 0.001 | |
4 | 0 | 18 | 2 | ||||
5 | 0 | 5 | 132 | ||||
60 keV VMIs | 3 | 2 | 1 | 0 | 0.766 | < 0.001 | |
4 | 1 | 32 | 5 | ||||
5 | 0 | 9 | 107 | ||||
70 keV VMIs | 3 | 11 | 0 | 0 | 0.789 | < 0.001 | |
4 | 0 | 107 | 4 | ||||
5 | 0 | 11 | 24 |
Table 6 Interobserver agreement for T-staging assessments between two radiologists for 40-70 keV virtual monoenergetic images and polyenergetic images (n = 157)
Images | T staging | Doctor B | |||||
T1 | T2 | T3-4 | κ | P value | |||
Doctor A | Axial PEIs | T1 | 2 | 0 | 0 | 0.891 | < 0.001 |
T2 | 1 | 29 | 3 | ||||
T3-4 | 0 | 2 | 123 | ||||
OA PEIs | T1 | 2 | 0 | 0 | 0.899 | < 0.001 | |
T2 | 1 | 33 | 2 | ||||
T3-4 | 0 | 3 | 116 | ||||
40 keV OA VMIs | T1 | 15 | 0 | 0 | 0.943 | < 0.001 | |
T2 | 1 | 14 | 2 | ||||
T3-4 | 0 | 0 | 125 | ||||
50 keV OA VMIs | T1 | 13 | 0 | 0 | 0.924 | < 0.001 | |
T2 | 2 | 15 | 2 | ||||
T3-4 | 0 | 0 | 125 | ||||
60 keV OA VMIs | T1 | 4 | 1 | 0 | 0.843 | < 0.001 | |
T2 | 2 | 21 | 3 | ||||
T3-4 | 0 | 2 | 124 | ||||
70 keV OA VMIs | T1 | 3 | 0 | 0 | 0.906 | < 0.001 | |
T2 | 1 | 27 | 3 | ||||
T3-4 | 0 | 1 | 122 |
Table 7 Diagnostic performance of 40-70 keV virtual monoenergetic images and polyenergetic images in preoperative staging of T1-2 and T3-4 colorectal cancer
Images | CT T-staging | Pathological staging | Accuracy (%) | Sensitivity (%) | Specificity (%) | Youden index | |
T1-2 (n = 31) | T3-4 (n = 126) | ||||||
Axial PEIs | T1-2 | 12 | 19 | 70.7 | 38.71 | 78.56 | 0.17 |
T3-4 | 27 | 99 | |||||
PFS | T1-2 | 17 | 14 | 68.79 | 54.84 | 72.22 | 0.27 |
T3-4 | 35 | 91 | |||||
Axial PEIs and PFS | T1-2 | 12 | 19 | 70.7 | 38.71 | 78.56 | 0.17 |
T3-4 | 27 | 99 | |||||
OA PEIs | T1-2 | 14 | 17 | 76.43 | 45.16 | 84.13 | 0.29 |
T3-4 | 20 | 106 | |||||
PFS | T1-2 | 25 | 6 | 73.89 | 80.65 | 72.22 | 0.53 |
T3-4 | 35 | 91 | |||||
OA PEIs and PFS | T1-2 | 14 | 17 | 77.07 | 45.16 | 84.92 | 0.30 |
T3-4 | 19 | 107 | |||||
40 keV OA VIMs | T1-2 | 26 | 5 | 94.27 | 83.87 | 96.83 | 0.81 |
T3-4 | 4 | 122 | |||||
PFS | T1-2 | 25 | 6 | 73.25 | 80.65 | 71.43 | 0.52 |
T3-4 | 36 | 90 | |||||
40 keV OA VMIs and PFS | T1-2 | 25 | 6 | 93.63 | 80.65 | 96.83 | 0.77 |
T3-4 | 4 | 122 | |||||
50 keV OA VMIs | T1-2 | 26 | 5 | 94.27 | 83.87 | 96.83 | 0.81 |
T3-4 | 4 | 122 | |||||
PFS | T1-2 | 25 | 6 | 76.43 | 80.65 | 76.19 | 0.57 |
T3-4 | 36 | 96 | |||||
50 keV OA VMIs and PFS | T1-2 | 25 | 6 | 93.63 | 80.65 | 96.83 | 0.77 |
T3-4 | 4 | 122 | |||||
60 keV OA VMIs | T1-2 | 18 | 13 | 84.08 | 58.06 | 90.48 | 0.49 |
T3-4 | 12 | 114 | |||||
PFS | T1-2 | 25 | 6 | 73.25 | 80.65 | 71.43 | 0.52 |
T3-4 | 36 | 90 | |||||
60 keV OA VMIs and PFS | T1-2 | 18 | 13 | 84.08 | 58.06 | 90.48 | 0.49 |
T3-4 | 12 | 114 | |||||
70 keV OA VMIs | T1-2 | 16 | 15 | 80.25 | 51.61 | 87.30 | 0.39 |
T3-4 | 16 | 110 | |||||
PFS | T1-2 | 25 | 6 | 73.25 | 80.65 | 71.43 | 0.52 |
T3-4 | 36 | 90 | |||||
70 keV OA VMIs and PFS | T1-2 | 16 | 15 | 80.25 | 51.61 | 87.30 | 0.39 |
T3-4 | 16 | 110 |
- Citation: Chen FX, Jiang KK, Zhu JF, Wang MR, Fan XL, Yang JS, He BS. Diagnostic accuracy of dual-layer spectral computed tomography virtual monoenergetic imaging with multiplanar reformation for T-staging of colorectal cancer. World J Gastroenterol 2025; 31(32): 110573
- URL: https://www.wjgnet.com/1007-9327/full/v31/i32/110573.htm
- DOI: https://dx.doi.org/10.3748/wjg.v31.i32.110573