Brief Article
Copyright ©2013 Baishideng Publishing Group Co., Limited. All rights reserved.
World J Gastroenterol. Jul 21, 2013; 19(27): 4334-4343
Published online Jul 21, 2013. doi: 10.3748/wjg.v19.i27.4334
Optical diagnosis of colorectal polyps using high-definition i-scan: An educational experience
Mariëlle WE Bouwens, Rogier de Ridder, Ad AM Masclee, Ann Driessen, Robert G Riedl, Bjorn Winkens, Silvia Sanduleanu
Mariëlle WE Bouwens, Rogier de Ridder, Ad AM Masclee, Silvia Sanduleanu, Division of Gastroenterology and Hepatology, Department of Internal Medicine, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands
Mariëlle WE Bouwens, Ad AM Masclee, NUTRIM, School for Nutrition, Toxicology and Metabolism, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands
Ann Driessen, Robert G Riedl, Department of Pathology, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands
Bjorn Winkens, Department of Methodology and Statistics, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands
Silvia Sanduleanu, GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, 6202 AZ Maastricht, The Netherlands
Author contributions: Bouwens MWE, de Ridder R, Masclee AAM, Driessen A, Riedl RG and Sanduleanu S contributed to the acquisition of data; Bouwens MWE, Winkens B and Sanduleanu S were involved in analysis and interpretation of data; Winkens B performed the statistical analysis; Bouwens MWE, Masclee AAM and Sanduleanu S wrote the manuscript; Sanduleanu S designed and supervised the study.
Correspondence to: Dr. Silvia Sanduleanu, MD, PhD, Consultant Gastroenterologist, Division of Gastroenterology and Hepatology, Department of Internal Medicine, Maastricht University Medical Center, P Debyelaan 25, 6202 AZ Maastricht, The Netherlands. s.sanduleanu@mumc.nl
Telephone: +31-43-3875021 Fax: +31-43-3875006
Received: February 22, 2013
Revised: March 29, 2013
Accepted: June 1, 2013
Published online: July 21, 2013
Processing time: 148 Days and 4.6 Hours
Abstract

AIM: To examine performances regarding prediction of polyp histology using high-definition (HD) i-scan in a group of endoscopists with varying levels of experience.

METHODS: We used a digital library of HD i-scan still images, comprising twin pictures (surface enhancement and tone enhancement), collected at our university hospital. We defined endoscopic features of adenomatous and non-adenomatous polyps, according to the following parameters: color, surface pattern and vascular pattern. We familiarized the participating endoscopists on optical diagnosis of colorectal polyps using a 20-min didactic training session. All endoscopists were asked to evaluate an image set of 50 colorectal polyps with regard to polyp histology. We classified the diagnoses into high confidence (i.e., cases in which the endoscopist could assign a diagnosis with certainty) and low confidence diagnoses (i.e., cases in which the endoscopist preferred to send the polyp for formal histology). Mean sensitivity, specificity and accuracy per endoscopist/image were computed and differences between groups tested using independent-samples t tests. High vs low confidence diagnoses were compared using the paired-samples t test.

RESULTS: Eleven endoscopists without previous experience on optical diagnosis evaluated a total of 550 images (396 adenomatous, 154 non-adenomatous). Mean sensitivity, specificity and accuracy for diagnosing adenomas were 79.3%, 85.7% and 81.1%, respectively. No significant differences were found between gastroenterologists and trainees regarding performances of optical diagnosis (mean accuracy 78.0% vs 82.9%, P = 0.098). Diminutive lesions were predicted with a lower mean accuracy as compared to non-diminutive lesions (74.2% vs 93.1%, P = 0.008). A total of 446 (81.1%) diagnoses were made with high confidence. High confidence diagnoses corresponded to a significantly higher mean accuracy than low confidence diagnoses (84.0% vs 64.3%, P = 0.008). A total of 319 (58.0%) images were evaluated as having excellent quality. Considering excellent quality images in conjunction with high confidence diagnosis, overall accuracy increased to 92.8%.

CONCLUSION: After a single training session, endoscopists with varying levels of experience can already provide optical diagnosis with an accuracy of 84.0%.

Keywords: Colonoscopy; High-definition i-scan; Optical diagnosis; Colorectal polyps; Training

Core tip: Several studies examined the feasibility of optical diagnosis of colorectal polyps using chromoendoscopy, either dye-based or digital techniques, while only a few studies examined the performances using the high-definition (HD) i-scan technology. In addition, experience on prediction of polyp histology using HD i-scan has been reported in an expert setting only, was based on various classification criteria, and paid only a limited attention to the impact of training. In the current study, at our university hospital, we investigated the effect of training on the diagnostic performances of endoscopists with varying levels of experience. We found that, after a short didactic training session, all endoscopists, trainees as well as gastroenterologists, can predict polyp histology with a mean accuracy of 84%.