1
|
Sun JX, Cai AL, Xie LM. Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation. World J Clin Cases 2019; 7:2003-2012. [PMID: 31423432 PMCID: PMC6695553 DOI: 10.12998/wjcc.v7.i15.2003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 06/12/2019] [Accepted: 07/03/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment. The new intelligent spatiotemporal image correlation (iSTIC) technology acquires high-resolution volumetric images. In this study, the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function.
AIM To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses.
METHODS Between October 2014 and September 2015, a total of 123 pregnant women received prenatal ultrasound examinations in our hospital. iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software. Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve. The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume. The data were used to calculate the right stroke volume, the right cardiac output, and the right ejection fraction. The correlations of changes between the above-mentioned indices and gestational age were analyzed. The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer, and the intra-observer agreement measurements were calculated.
RESULTS Among the 123 normal fetuses, the mean right ventricular end-diastolic volume increased from 0.99 ± 0.34 mL at 22 wk gestation to 3.69 ± 0.36 mL at 35+6 wk gestation. The mean right ventricular end-systolic volume increased from 0.43 ± 0.18 mL at 22 wk gestation to 1.36 ± 0.22 mL at 35+6 wk gestation. The mean right stroke volume increased from 0.62 ± 0.29 mL at 22 wk gestation to 2.33 ± 0.18 mL at 35+6 wk gestation. The mean right cardiac output increased from 92.23 ± 40.67 mL/min at 22 wk gestation to 335.83 ± 32.75 mL/min at 35+6 wk gestation. Right ventricular end-diastolic volume, right ventricular end-systolic volume, right stroke volume, and right cardiac output all increased with gestational age and the correlations were linear (P < 0.01). Right ejection fraction had no apparent correlation with gestational age (P > 0.05).
CONCLUSION Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability. iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function.
Collapse
Affiliation(s)
- Jia-Xing Sun
- Ultrasound Department, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Ai-Lu Cai
- Ultrasound Department, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
| | - Li-Mei Xie
- Ultrasound Department, Shengjing Hospital of China Medical University, Shenyang 110004, Liaoning Province, China
- Ultrasound Department, Roicare Hospital and Clinics, Shenyang 110004, Liaoning Province, China
| |
Collapse
|
2
|
Dell’Oro S, Verderio M, Incerti M, Mastrolia SA, Cozzolino S, Vergani P. 2D versus 3D real time ultrasound with live xPlane imaging to visualize aortic and ductal arches: comparison between methods. PeerJ 2018; 6:e4561. [PMID: 29637020 PMCID: PMC5890721 DOI: 10.7717/peerj.4561] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2018] [Accepted: 03/10/2018] [Indexed: 11/20/2022] Open
Abstract
Background The diagnosis of congenital heart defects is challenging, especially for what concerns conotruncal anomalies. Indeed, although the screening techniques of fetal cardiac anomalies have greatly improved, the detection rate of conotruncal anomalies still remains low due to the fact that they are associated with a normal four-chamber view. Therefore, the study aimed to compare real-time three-dimensional echocardiography with live xPlane imaging with two-dimensional (2D) traditional imaging in visualizing ductal and aortic arches during routine echocardiography of the second trimester of gestation. Methods This was an observational prospective study including 114 women with uncomplicated, singleton pregnancies. All sonographic studies were performed by two different operators, of them 60 by a first level operator, while 54 by a second level operator. A subanalysis was run in order to evaluate the feasibility and the time needed for the two procedures according to fetal spine position and operator’s experience. Results The measurements with 2D ultrasound were performed in all 114 echocardiographies, while live xPlane imaging was feasible in the 78% of the cases, and this was mainly due to fetal position. The time lapse needed to visualize aortic and ductal arches was significantly lower when using 2D ultrasound compared to live xPlane imaging (29.56 ± 28.5 s vs. 42.5 ± 38.1 s, P = 0.006 for aortic arch; 22.14 ± 17.8 s vs. 37.1 ± 33.8 s, P = 0.001 for ductal arch), also when performing a subanalysis according to operators’ experience (P < 0.05 for all comparisons). Feasibility of live xPlane proved to be correlated with the position of the fetal spine and the operator’s experience. Discussion To find a reproducible and standardized method to detect fetal heart defects may bring a great benefit for both patients and operators. In this scenario live xPlane imaging is a novel method to visualize ductal and aortic arches. We found that the position of the fetal spine may affect the feasibility of the method since, when the fetal back is anterior or transverse, the visualization of the correct view of three-vessels and trachea in order to set the reference line properly becomes more challenging. In addition, the fetal spine position influences the duration of the ultrasound examination. Regarding operator’s skills and experience, in our study a first level operator was able to perform the complete 2D and xPlane examination in a lower number of cases compared to second level operators. In addition, the time required for the complete examination was higher for first level operators. This means that this technique is based on an adequate operators’ expertise.
Collapse
|
3
|
Lu Y, Yang T, Luo H, Deng F, Cai Q, Sun W, Song H. Visualization and quantitation of fetal movements by real-time three-dimensional ultrasound with live xPlane imaging in the first trimester of pregnancy. Croat Med J 2017; 57:474-481. [PMID: 27815938 PMCID: PMC5141454 DOI: 10.3325/cmj.2016.57.474] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Aim To prove whether real-time three-dimensional (3D) ultrasound with live xPlane imaging is better in observing fetal movements than standard ultrasound imaging. Methods 50 healthy women with singleton pregnancies (22-43 years old) at 11 to 14 weeks of gestation underwent real-time 3D ultrasound examination with live xPlane imaging from July 2014 to February 2015. The incidence and frequency of 10 fetal movement patterns in 10 minutes were evaluated, including general movements (GMs), isolated arm movements, isolated leg movements, hiccup, stretching, breathing, startle, jaw opening, isolated head retroflexion, and isolated head anteflexion. The correlation between gestational age and frequency of each fetal movement pattern was analyzed. Results GM had the highest incidence (100%), followed by startle (84%) and isolated arm movements (68%). Their median frequency was 5 (IQR 3-6), 5 (IQR 1.75-11.5), and 1 (IQR 0-2), respectively. GM (Z = 5.875, P < 0.001) and startle (Z = 5.302, P < 0.001) had significantly higher frequency than isolated arm movements. The other 7 fetal movement patterns had much lower incidence and frequency. The frequency of GM was positively correlated with gestational age (r = 0.360, P = 0.010). Conclusion Real-time 3D ultrasound with live x Plane imaging was shown to be a feasible tool for observing fetal movements.
Collapse
Affiliation(s)
| | | | - Hong Luo
- Hong Luo, Department of Diagnostic Ultrasound, West China Second University Hospital, Sichuan University, Key Laboratory of Birth Defects and Related Diseases of Women and Children, Ministry of Education, No. 20, Section 3, Renmin Nanlu, Chengdu, Sichuan 610041, China,
| | | | | | | | | |
Collapse
|
4
|
Tonni G, Martins WP, Guimarães Filho H, Araujo Júnior E. Role of 3-D ultrasound in clinical obstetric practice: evolution over 20 years. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1180-1211. [PMID: 25748522 DOI: 10.1016/j.ultrasmedbio.2014.12.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2014] [Revised: 12/10/2014] [Accepted: 12/11/2014] [Indexed: 06/04/2023]
Abstract
The use of 3-D ultrasound in obstetrics has undergone dramatic development over the past 20 years. Since the first publications on this application in clinical practice, several 3-D ultrasound techniques and rendering modes have been proposed and applied to the study of fetal brain, face and cardiac anatomy. In addition, 3-D ultrasound has improved calculations of the volume of fetal organs and limbs and estimations of fetal birth weight. And furthermore, angiographic patterns of fetal organs and the placenta have been assessed using 3-D power Doppler ultrasound quantification. In this review, we aim to summarize current evidence on the clinical relevance of these methodologies and their application in obstetric practice.
Collapse
Affiliation(s)
- Gabriele Tonni
- Department of Obstetrics and Gynecology, Guastalla Civil Hospital, ASL Reggio Emilia, Italy; Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil
| | - Wellington P Martins
- Department of Obstetrics and Gynecology, Ribeirão Preto School of Medicine, University of São Paulo (DGO-FMRP-USP), Ribeirão Preto-SP, Brazil
| | | | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine, Federal University of São Paulo (EPM-UNIFESP), São Paulo-SP, Brazil.
| |
Collapse
|
5
|
Acar P, Battle L, Dulac Y, Peyre M, Dubourdieu H, Hascoet S, Groussolles M, Vayssière C. Real-time three-dimensional foetal echocardiography using a new transabdominal xMATRIX array transducer. Arch Cardiovasc Dis 2013; 107:4-9. [PMID: 24364911 DOI: 10.1016/j.acvd.2013.10.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2013] [Revised: 10/18/2013] [Accepted: 10/24/2013] [Indexed: 02/06/2023]
Abstract
BACKGROUND Foetal echocardiography has been used to diagnose congenital heart disease. However, conventional echocardiography can only display two-dimensional (2D) structural images of the intricate three-dimensional (3D) foetal heart. AIM The purpose of this study was to report the first use of a new transabdominal xMATRIX array transducer and to describe its ability to perform all 3D modalities: intelligent spatiotemporal image correlation (iSTIC) acquisition, xPlane imaging and 3D surface imaging. METHODS Eighty foetuses without congenital heart disease were included consecutively, with a gestational age between 20 and 37 weeks. 2D and 3D scans were performed with a transabdominal xMATRIX array transducer. Cardiac-STIC volume datasets were acquired and postprocessed with new automatic software (the 'Fetal Heart Navigator'). RESULTS A total of 224 iSTIC acquisitions were performed (mean time for each, 2 seconds). Only 78 iSTIC acquisitions (35%) were able to detect the ductal arch automatically. 'Fetal Heart Navigator' feasibility varied according to foetal position, including the descending aorta. Live xPlane imaging had excellent feasibility regardless of foetal position; using rotation, lateral and vertical tilts, all cardiac structures were identified from a unique reference plane. Live 3D surface imaging had variable feasibility depending on the target structure. Only 10% of the volume dataset offered comprehensive imaging of intracardiac views. CONCLUSION The new xMATRIX transabdominal transducer allows a multimodality approach to the foetal heart. Further studies that include foetuses with cardiac malformations are required.
Collapse
Affiliation(s)
- Philippe Acar
- Department of Paediatric Cardiology, Children's Hospital, 330, avenue de Grande-Bretagne, 31059 Toulouse cedex 9, France.
| | - Laia Battle
- Department of Obstetrics and Gynaecology, Mother's Hospital, Toulouse, France
| | - Yves Dulac
- Department of Paediatric Cardiology, Children's Hospital, 330, avenue de Grande-Bretagne, 31059 Toulouse cedex 9, France
| | - Marianne Peyre
- Department of Paediatric Cardiology, Children's Hospital, 330, avenue de Grande-Bretagne, 31059 Toulouse cedex 9, France
| | - Hélène Dubourdieu
- Department of Obstetrics and Gynaecology, Mother's Hospital, Toulouse, France
| | - Sébastien Hascoet
- Department of Paediatric Cardiology, Children's Hospital, 330, avenue de Grande-Bretagne, 31059 Toulouse cedex 9, France
| | - Marion Groussolles
- Department of Obstetrics and Gynaecology, Mother's Hospital, Toulouse, France
| | | |
Collapse
|
6
|
Acar P. [Echocardiography for fetuses and children: what's new?]. Arch Pediatr 2013; 20:1072-4. [PMID: 23953870 DOI: 10.1016/j.arcped.2013.06.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Accepted: 06/28/2013] [Indexed: 10/26/2022]
Affiliation(s)
- P Acar
- Service de cardiologie pédiatrique et fœtale, hôpital Mère-Enfant, CHU de Toulouse, 330, avenue de Grande-Bretagne, 31059 Toulouse cedex 9, France.
| |
Collapse
|
7
|
Gregg CL, Butcher JT. Translational paradigms in scientific and clinical imaging of cardiac development. ACTA ACUST UNITED AC 2013; 99:106-20. [PMID: 23897595 DOI: 10.1002/bdrc.21034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2013] [Accepted: 05/14/2013] [Indexed: 01/25/2023]
Abstract
Congenital heart defects (CHD) are the most prevalent congenital disease, with 45% of deaths resulting from a congenital defect due to a cardiac malformation. Clinically significant CHD permit survival upon birth, but may become immediately life threatening. Advances in surgical intervention have significantly reduced perinatal mortality, but the outcome for many malformations is bleak. Furthermore, patients living while tolerating a CHD often acquire additional complications due to the long-term systemic blood flow changes caused by even subtle anatomical abnormalities. Accurate diagnosis of defects during fetal development is critical for interventional planning and improving patient outcomes. Advances in quantitative, multidimensional imaging are necessary to uncover the basic scientific and clinically relevant morphogenetic changes and associated hemodynamic consequences influencing normal and abnormal heart development. Ultrasound is the most widely used clinical imaging technology for assessing fetal cardiac development. Ultrasound-based fetal assessment modalities include motion mode (M-mode), two dimensional (2D), and 3D/4D imaging. These datasets can be combined with computational fluid dynamics analysis to yield quantitative, volumetric, and physiological data. Additional imaging modalities, however, are available to study basic mechanisms of cardiogenesis, including optical coherence tomography, microcomputed tomography, and magnetic resonance imaging. Each imaging technology has its advantages and disadvantages regarding resolution, depth of penetration, soft tissue contrast considerations, and cost. In this review, we analyze the current clinical and scientific imaging technologies, research studies utilizing them, and appropriate animal models reflecting clinically relevant cardiogenesis and cardiac malformations. We conclude with discussing the translational impact and future opportunities for cardiovascular development imaging research.
Collapse
Affiliation(s)
- Chelsea L Gregg
- Department of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA
| | | |
Collapse
|
8
|
Three-Dimensional Echocardiography in Congenital Heart Disease. CURRENT PEDIATRICS REPORTS 2013. [DOI: 10.1007/s40124-013-0014-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|