1
|
D'Agostino C, Di Martino A, Cataldi P, Schilardi F, Brunello M, Geraci G, Bordini B, Traina F, Faldini C. A Registry Study on Acetabular Revisions Using Jumbo Cups: Do We Really Need a More Complex Revision Strategy? J Arthroplasty 2025; 40:738-743. [PMID: 39233106 DOI: 10.1016/j.arth.2024.08.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/23/2024] [Accepted: 08/26/2024] [Indexed: 09/06/2024] Open
Abstract
BACKGROUND The increasing global performance of total hip arthroplasty (THA) has led to a rise in revision surgeries, primarily due to cup failure, with aseptic loosening and periprosthetic infection being common causes. Various techniques and implants, including jumbo cups (JCs), manage residual bone loss post-cup removal, facilitating enhanced surface area for improved host bone contact, and osteointegration. The purpose of the study was to determine the outcomes of acetabular revision arthroplasty using JC implants over a 20-year follow-up period by reporting overall survivorships, complications leading to re-revision, and surgical strategies in re-revision. METHODS A cohort study based on a large regional registry was conducted, examining revision THA surgeries utilizing JCs between 2000 and 2020. The study included all the revision acetabular procedures performed with cementless JCs, identified with a diameter ≥ 62 millimeters (mm) in women or ≥ 66 mm in men. All iliac fixation cups were excluded. Data on demographics, revision surgery indications, components, fixation types, causes of failure, and reintervention strategies were collected and analyzed. A total of 541 JCs implanted from January 2000 to December 2020 were evaluated. The most common revision indications were "cup aseptic loosening" (54.5%) and "total aseptic loosening," which included both the cup and stem (32%). RESULTS The JC survival rates were 92.5% at 5 years, 85.8% at 10 years, and 81.5% at 15 years. Among the 70 failures, the main causes were "cup aseptic loosening" (40%), "total aseptic loosening" (17.1%), and "septic loosening" (12.8%). Revisions primarily involved acetabular cup revision surgery (54 cases), component explantation (11 cases), or insert or head revision (five cases). CONCLUSIONS This registry-based study of JCs in revision THA demonstrates excellent 15-year survival rates and acceptable failure rates. It supports JCs as a viable option, offering relative surgical simplicity compared to alternatives like antiprotrusion cages, bone grafts, and augments.
Collapse
Affiliation(s)
- Claudio D'Agostino
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Alberto Di Martino
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Piergiorgio Cataldi
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Francesco Schilardi
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Matteo Brunello
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| | - Giuseppe Geraci
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Barbara Bordini
- Medical Technology Laboratory, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Francesco Traina
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy; Department of Orthopaedics and Traumatology and Hip and Knee Arthroplasty and Revisions, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy
| | - Cesare Faldini
- 1st Orthopaedic and Traumatology Department, IRCCS Rizzoli Orthopaedic Institute, Bologna, Italy; Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy
| |
Collapse
|
2
|
Jovanovic Z, Vukomanovic B, Aleksandric D, Jeremic D, Miceta L, Zarkovic ND, Slavkovic N. The Use of Porous Titanium Metal Augments for Acetabular Defects in Total Hip Arthroplasty: Initial Results From a Single-Center Experience. Cureus 2025; 17:e77307. [PMID: 39935914 PMCID: PMC11811741 DOI: 10.7759/cureus.77307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/12/2025] [Indexed: 02/13/2025] Open
Abstract
Background and objective One of the major challenges that orthopaedic surgeons face during revision total hip arthroplasty (THA) is the presence of acetabular bone defects. Nowadays, preference is given to metal augments when it comes to segmental, uncontained defects. This study aimed to present the previous experience at our hospital in the use of porous metal augments for bony defects of the acetabulum. Methods Our retrospective observational study included a total of 30 patients who underwent revision or primary THA with the use of porous metal acetabular augmentation between 2021 and 2024. The extent and localization of acetabular bone defects were assessed on preoperative X-ray series and CT scans, confirmed intraoperatively, and classified using the Paprosky classification. The functional status of the patients was evaluated using the Modified Harris Hip Score (mHHS). The complications were defined as adverse outcomes requiring rehospitalization and further treatment. Statistical data analysis was performed using SPSS Statistics version 28.0 (IBM Corp., Armonk, NY). Results Surgeries were performed by 14 different orthopaedic surgeons, using a posterolateral hip approach in all cases. Pinnacle Multihole® cementless acetabular shell and Gription® TF augment (DePuy Synthes, Raynham, MA) were implanted in all patients. Revision of the acetabular component was indicated due to mechanical complications in 19 patients (64%), and periprosthetic infection in nine (30%) patients. In two cases (6%) metal augment was used in primary hip arthroplasty. As for acetabular defects, Paprosky type IIb defect was observed in nine cases (30%), type IIc in five cases (16%), type IIIa in 12 (40%), and type IIIb defect in four cases (14%). The analysis of mHHS showed a significant improvement after the operative treatment and the completion of the rehabilitation. Complications of surgical treatment were observed in five patients (16%). Conclusions Based on our findings, the use of metal augments is a reliable surgical method that enables the surgeon to deal with various defects of the acetabulum bone mass, ensuring the establishment of favourable biomechanical conditions in the hip joint.
Collapse
Affiliation(s)
- Zelimir Jovanovic
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| | - Boris Vukomanovic
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| | - Dejan Aleksandric
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| | - Danilo Jeremic
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| | - Lazar Miceta
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| | - Nikola D Zarkovic
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| | - Nemanja Slavkovic
- Orthopaedics and Traumatology, Institute for Orthopaedics Banjica, Belgrade, SRB
| |
Collapse
|
3
|
Huan SW, Wu WR, Peng SJ, Zhuang TF, Liu N. Total hip arthroplasty after pelvic osteotomy: a meta-analysis. Acta Orthop Belg 2024; 90:523-533. [PMID: 39851025 DOI: 10.52628/90.3.10758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2025]
Abstract
Several studies suggested that total hip arthroplasty (THA) was more technical demanding following previous pelvic osteotomy (PO), resulting in poor outcomes compared with primary THA. However, the other studies regarding this topic had reported contradictory results. Therefore, we conducted this meta-analysis to compare the clinical results and other parameters between total hip arthroplasty following pelvic osteotomy and primary total hip arthroplasty. We systematically searched PubMed, the Cochrane Library, EMBASE, Web of Science, Scopus, EBSCO and Web of science from inception to September 2020. This study compared the outcomes between THA following previous PO and primary THA with respect to operative time, blood loss, Harris hip score (HHS), revision rates, complication rates, cup position, cup size, cup coverage and hip joint center. 14 studies with 3913 participants were included. The THA after PO group had longer operative time (MD, 13.8 mins; 95% CI, 4.73 to 22.87 mins; P=0.003), greater blood loss (MD, 82.21 ml; 95% CI, 27.94 to 136.48 ml; P=0.003), worse HHS (MD, -2.79 points; 95% CI, -4.08 to -1.50 points; P<0.00001), smaller acetabular anteversion angle (MD, -3.98°; 95% CI, -6.72 to -1.24°; P=0.004), larger cup size (MD, 1.52 mm; 95% CI, 0.75 to 2.28 mm; P=0.0001), more lateral (MD, 2.83 mm; 95% CI, 1.22 to 4.43 mm; P=0.0005) and superior (MD, 2.26 mm; 95% CI, 1.11 to 3.40 mm; P=0.0001) hip joint center. No statistically significant differences were demonstrated between the THA after PO group and primary THA group in revision rates, complication rates, acetabular abduction angle, cup coverage. THA after pelvic osteotomy was associated with inferior intraoperative outcomes, lower functional scores and worse inferior positioning of acetabular component compared with primary THA. Due to the alerted anatomical structure after PO, the findings of current study implicated that preoperative assessment such as computed tomography scan should be conducted in order to achieve satisfactory results.
Collapse
|
4
|
Loppini M, Guazzoni E, Gambaro FM, La Camera F, Morenghi E, Grappiolo G. A new classification to characterize and predict treatment of acetabular bone defects. Arch Orthop Trauma Surg 2024; 144:2975-2981. [PMID: 38864926 DOI: 10.1007/s00402-024-05327-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 04/14/2024] [Indexed: 06/13/2024]
Abstract
BACKGROUND The increasing amount of revision surgeries in total hip arthroplasty (THA) represents a burden for orthopedic surgeons given the complexity and unpredictability of this kind of surgery. The aim of the current study was to develop a new radiographic classification of acetabular bone defects stratify the severity of the lesion and to suggest the surgical strategy to address it. METHODS Radiographs of 151 consecutive patients who underwent acetabular revision surgery in our institution were collected to develop a new classification that groups the acetabular bone defects in three zones (A, B and C). The performance to predict treatment and inter- and intra-rater agreement were evaluated. RESULTS The ability of the newly proposed classification to predict treatment was 87.3% (k weighted: 0.65). The inter-rater reliability was 90.1% (k: 0.81), and the intra-rater reliability between the two sets of evaluations performed by the observer at 1-month distance was 97.5% (k: 0.94). CONCLUSIONS The newly proposed classification was able to characterize the extent of acetabular bone defects and predict pre-operatively the appropriate surgical treatment strategy in 87.3% of cases. It showed a strong agreement among raters and an almost perfect agreement among different measurements at 1 month distance. This new tool could be used in the preoperative assessment to drive the use of secondary level image examinations and the type of surgical management.
Collapse
Affiliation(s)
- Mattia Loppini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, Milan, 20072, Italy.
- IRCCS Humanitas Research Hospital, Via A. Manzoni 56, Rozzano, Milan, 20089, Italy.
- Fondazione Livio Sciutto Onlus, Campus Savona - Università degli Studi di Genova, Via Magliotto 2, Savona, 17100, Italy.
| | - Edoardo Guazzoni
- IRCCS Humanitas Research Hospital, Via A. Manzoni 56, Rozzano, Milan, 20089, Italy
- Fondazione Livio Sciutto Onlus, Campus Savona - Università degli Studi di Genova, Via Magliotto 2, Savona, 17100, Italy
| | - Francesco Manlio Gambaro
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, Milan, 20072, Italy
- IRCCS Humanitas Research Hospital, Via A. Manzoni 56, Rozzano, Milan, 20089, Italy
| | - Francesco La Camera
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, Milan, 20072, Italy
- IRCCS Humanitas Research Hospital, Via A. Manzoni 56, Rozzano, Milan, 20089, Italy
| | - Emanuela Morenghi
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Pieve Emanuele, Milan, 20072, Italy
| | - Guido Grappiolo
- IRCCS Humanitas Research Hospital, Via A. Manzoni 56, Rozzano, Milan, 20089, Italy
- Fondazione Livio Sciutto Onlus, Campus Savona - Università degli Studi di Genova, Via Magliotto 2, Savona, 17100, Italy
| |
Collapse
|
5
|
George J, Taylor AJ, Schmalzried TP. Examining the "revisability" benefit of hip resurfacing arthroplasty. World J Orthop 2024; 15:554-559. [PMID: 38947266 PMCID: PMC11212540 DOI: 10.5312/wjo.v15.i6.554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 04/20/2024] [Accepted: 04/26/2024] [Indexed: 06/12/2024] Open
Abstract
BACKGROUND Hip resurfacing arthroplasty (HRA) is an alternative to total hip arthroplasty (THA) that is typically reserved for young active patients because it preserves bone. However, the benefits of HRA only hold true if conversion THA after failed HRA provides acceptable outcomes. AIM To compare patient reported outcomes for conversion THA after HRA failure to primary THA. METHODS A retrospective review of 36 patients (37 hips) that underwent conversion THA for failed HRA between October 2006 and May 2019 by a single surgeon was performed. Patient reported outcomes [modified Harris Hip Score (mHHS), University of California Los Angeles (UCLA) activity score] were obtained via an email-based responder-anonymous survey. Outcomes were compared to normative data of a primary THA cohort with similar demographics. Subgroup analysis was performed comparing outcomes of conversion THA for adverse local tissue reaction (ALTR) vs all other causes for failure. RESULTS The study group had a lower mHHS than the control group (81.7 ± 13.8 vs 90.2 ± 11.6, P < 0.01); however, both groups had similar UCLA activity levels (7.5 ± 2.3 vs 7.2 ± 1.6, P = 0.51). Patients that underwent conversion for non-ATLR causes had similar mHHS (85.2 ± 11.5 vs 90.2 ± 11.6, P = 0.11) and higher UCLA activity levels (8.5 ± 1.8 vs 7.2 ± 1.6, P < 0.01) compared to the control group. Patients that underwent conversion for ATLR had worse mHHS (77.1 ± 14.5 vs 90.2 ± 11.6, P < 0.01) and UCLA activity levels (6.1 ± 2.3 vs 7.2 ± 1.6, P = 0.05) when compared to the control group. CONCLUSION Patient outcomes equivalent to primary THA can be achieved following HRA conversion to THA. However, inferior outcomes were demonstrated for ALTR-related HRA failure. Patient selection and perhaps further studies examining alternative HRA bearing surfaces should be considered.
Collapse
Affiliation(s)
- Jose George
- Department of Orthopedics, Harbor UCLA Medical Center, Torrance, CA 90509, United States
| | - Adam J Taylor
- Department of Orthopedics, Harbor UCLA Medical Center, Torrance, CA 90509, United States
| | - Thomas P Schmalzried
- Department of Orthopedics, Harbor UCLA Medical Center, Torrance, CA 90509, United States
| |
Collapse
|
6
|
Tikhilov RM, Kovalenko AN, Dzhavadov AA, Bilyk SS, Shubnyakov II. Intrawound navigation for custom-made acetabular component in revision total hip arthroplasty: Does it improve implant positioning? J Orthop 2024; 48:6-12. [PMID: 38059213 PMCID: PMC10696182 DOI: 10.1016/j.jor.2023.11.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/13/2023] [Indexed: 12/08/2023] Open
Abstract
Background The number of hip revisions makes up over 12 % of all hip arthroplasty cases. For large acetabular defects custom-made acetabular component (CMAC) are required. Rates of malposition of CMACs are highly variable. Our study aims to develop a readily available, reliable and easily reproducible method for positioning of the CMAC. We tried to answer the following questions: 1) how often does the postoperative position of the implant corresponds to the planned one; 2) is the use of intrawound navigation improve the precision of acetabular implant position. Methods This was a single-center observational cohort study and included two groups: the experimental group (use of 3D navigation for implant positioning) and the control group (no navigation use). All the patients were scheduled for acetabular revision surgery with custom-made 3D-printed acetabular components. All surgeries took place between 2016 and 2020. Results 25 % freehand group, 85 % implants in the navigation group matched accuracy positioning criteria. The relative risk of malposition was significantly higher without the intraoperative navigation, with 5 times greater risk of malpositioning in the freehand group versus the navigation group. Conclusion Navigation method allows planning of the implant and reamer sizes for optimal bone preparation and preservation. It provides easier implantation of the complex implant with reliable, stable primary fixation in massive bone defects. It reliably decreases malposition rate, allowing for implant placement in a proper position with sufficient bone-implant contact. Further research is needed to determine the relationship between CMAC position accuracy and long-term clinical and radiographic outcomes.
Collapse
Affiliation(s)
- Rashid M. Tikhilov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Anton N. Kovalenko
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Alisagib A. Dzhavadov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Stanislav S. Bilyk
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Igor I. Shubnyakov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| |
Collapse
|
7
|
Álvarez Valdivielso A, Akkaya M, Mau H, Luo TD, Gehrke T, Citak M. Survival analysis of 3D printed acetabular implants in revision total hip arthroplasty associated with severe pelvic discontinuities. Technol Health Care 2024; 32:3783-3792. [PMID: 38427516 DOI: 10.3233/thc-231647] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/03/2024]
Abstract
BACKGROUND Surgeons still face difficulties when performing aseptic acetabular revision on patients with extensive defects. Advances in three-dimensional printing technology (3DP) have afforded to the surgeons to create a patient-specific implant matching the morphology and topography of the defect. OBJECTIVE The aim of the current research was to determine the survivorship in the treatment of acetabular bone defects with pelvic discontinuity (PD). METHODS In order to reconstruct Paprosky type III defects with PD, twenty-three patients underwent revision total hip arthroplasty (THA) utilizing 3D-printed implants (Mobelife). The primary outcomes were the implant-associated failure rate correlated with survivorship. As secondary variables, complications and the effect of age, sex, comorbidities, history of infections and the presence of other lower limb arthroplasties on a new revision were analyzed. RESULTS Patients were followed out to a mean of 67.22 ± 39.44 months (range, 0.9-127 months). Mobelife implant mean survival was 102.57 ± 9.90 months (95% CI 83.17-121.96). The cohort's implant one-year survival rate was 87%; at ten years, it dropped to 78.3%. There were four revisions: three due to periprosthetic joint infection (PJI) and one case due to aseptic loosening. Cox regression analysis did not identify any variable as predictor of failure. CONCLUSION The use of 3DP patient-specific acetabular components has shown encouraging results and it is a viable treatment option for addressing acetabular defects with combined PD in aseptic THA revision.
Collapse
Affiliation(s)
- Ainhoa Álvarez Valdivielso
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- Department of Traumatology and Orthopaedic Surgery, Hospital Universitario Son Espases, Palma de Mallorca, Spain
| | - Mustafa Akkaya
- Ankara Yildirim Beyazit University, Ankara City Hospital, Ankara, Turkey
| | - Hans Mau
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - T David Luo
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
- Orthopaedics Northeast, Fort Wayne, IN, USA
| | - Thorsten Gehrke
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopaedic Surgery, Helios ENDO-Klinik Hamburg, Hamburg, Germany
| |
Collapse
|
8
|
Wallace DT, Stoffel K, Baines J. Technical note: acetabular augmentation with customisable cementless all-polyethylene insert. Hip Int 2024; 34:92-95. [PMID: 37680129 DOI: 10.1177/11207000231194582] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/09/2023]
Abstract
Acetabular augmentation is a challenge for complex primary and revision hip surgery. Several methods exist to recreate a supportive, hemispherical acetabulum where a defect exists, however, these can be complex, expensive, time consuming, and limited by available size and shape. We present a simple, inexpensive, quick and customisable method of acetabular augmentation using cementless polyethylene with titanium coating. The first case is presented with follow-up up to 8 years.
Collapse
Affiliation(s)
- David T Wallace
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, West Dunbartonshire, UK
| | - Karl Stoffel
- Department of Orthopaedics and Traumatology, University Hospital of Basel, Basel, Basel-Stadt, Switzerland
| | - Joe Baines
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, West Dunbartonshire, UK
| |
Collapse
|
9
|
Fahlbusch H, Budin M, Volk A, von Rehlingen Prinz F, Linke P, Citak M, Gehrke T, Ohlmeier M. Long-term outcomes of total hip arthroplasty in patients with developmental dysplasia of the hip: a minimum 21-year follow-up. Arch Orthop Trauma Surg 2023; 143:6609-6616. [PMID: 37421515 DOI: 10.1007/s00402-023-04970-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 06/26/2023] [Indexed: 07/10/2023]
Abstract
PURPOSE Early osteoarthritis (OA) due to developmental dysplasia of the hip (DDH) is a known indication for total hip arthroplasty (THA). Though screening tools and joint-preserving procedures have been established successfully, there still is a relevant number of patients suffering DDH. Due to the lack of long-term outcome studies, we like to close this gap and present the results of a highly specialized center. METHODS The study included 126 patients, who were treated in our institution with primary THA for DDH between January 1997 and December 2000. At the time of final follow-up, at a mean of 23 years postoperatively, 110 patients (121 hips) were clinically evaluated using the Harris-Hip Score. In addition, complication and surgical revision rates were assessed. We collected surgery-related data like implant choice and special surgical features such as autologous acetabular reconstruction or femoral osteotomies. Additionally, the severity of preoperative DDH was measured radiographically according to Crowe classification. RESULTS There were 91 female (83%) and 19 male (17%) patients with an average age of 51 ± 9.5 years (range 21-65) included. Mean follow-up was 23 ± 1.3 years (21-25), with a minimum of 21 years being necessary for inclusion. Using revision for any indication as primary endpoint, the Kaplan-Meier survivorship was 98.3% at 10 years and 81.8% at final follow-up. The overall revision rate was 18% (22 cases), which were split up as follows: 20 (17%) implant failures (loosened or broken components), one (1%) periprosthetic infection and one (1%) periprosthetic fracture. Regarding complications, we observed nine (7%) dislocations and one case (1%) with severe heterotopic ossification that required surgical excision. The mean Harris-Hip score at latest follow-up was 78 ± 14 points (32-95). CONCLUSIONS Though implants and surgical techniques have improved over time, our results suggest THA in patients suffering DDH to be seriously challenging with relatively high overall complications in long-term observation and fair clinical outcome after 21 years postoperatively. There is evidence that prior osteotomy might be associated with a higher revision rate.
Collapse
Affiliation(s)
- Hendrik Fahlbusch
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Maximilian Budin
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany
| | - Annabelle Volk
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Fidelius von Rehlingen Prinz
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany
- Department of Trauma and Orthopaedic Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Philip Linke
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany
| | - Mustafa Citak
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany
| | - Thorsten Gehrke
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany
| | - Malte Ohlmeier
- Department of Orthopedic Surgery, Helios ENDO-Klinik Hamburg, Holstenstrasse 2, 22767, Hamburg, Germany.
- Department of Orthopaedic and Trauma Surgery, UKM Marienhospital, Mauritiusstraße 5, 48565, Steinfurt, Germany.
| |
Collapse
|
10
|
Yang C, Zhu K, Dai H, Zhang X, Wang Q, Wang Q. Mid- to Long-term Follow-up of Severe Acetabular Bone Defect after Revision Total Hip Arthroplasty Using Impaction Bone Grafting and Metal Mesh. Orthop Surg 2023; 15:750-757. [PMID: 36644857 PMCID: PMC9977582 DOI: 10.1111/os.13651] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 12/09/2022] [Accepted: 12/10/2022] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVE In revision total hip arthroplasty (THA), reconstruction of severe acetabular bone defect continues to be problematic for orthopedic surgeons. This study reports the mid- to long-term survivorship, radiological outcomes, and complications of impaction bone grafting (IBG) and metal mesh with a cemented acetabular component in the reconstruction of severe acetabular bone defects in revision THA. METHODS This retrospective consecutive study included 26 patients (29 hips: type II B, four; type II C, three; type III A, 10; and type III B, 12) who underwent revision THA, which was performed using IBG and metal mesh, between 2007 and 2014 in our institution. All patients were followed up regularly for clinical and radiographical assessments. Migration and loosening of prosthesis graft integration and complications were observed and analyzed. Survival analysis was performed using a Kaplan-Meier survival analysis. RESULTS At the time of revision, 75.9% of the hips (22 hips) were classified as type III bone defects. The average follow-up period was 9.4 ± 2.8 (range, 2.4-14.0) years. Of the 29 hips, four hips (13.8%) were assessed as clinical failures; at the last follow-up, two had undergone re-revision THA, and two had not been scheduled for re-revision THA despite radiological failure of the acetabular component. Among them, three clinical failures (10.3%) were due to aseptic loosening, and one (3.4%) was due to infection. Radiographic evaluation showed bone graft integration in all hips during the follow-up. The Kaplan-Meier survivorship analysis revealed an acetabular reconstruction survival rate of 86.5% (95% confidence interval, 61.4%-95.7%) at 10 years. CONCLUSION IBG and metal mesh with a cemented acetabular component for revision THA is an effective technique for treating severe acetabular bone defects, with effective mid- to long-term outcomes due to the solid reconstruction of the acetabular bone defect and restoration of the hip rotation center.
Collapse
Affiliation(s)
- Chao Yang
- Department of OrthopaedicsShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Kechao Zhu
- Department of OrthopaedicsShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Huiyong Dai
- Department of OrthopaedicsShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Xianlong Zhang
- Department of OrthopaedicsShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Qiaojie Wang
- Department of OrthopaedicsShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| | - Qi Wang
- Department of OrthopaedicsShanghai Jiao Tong University Affiliated Sixth People's HospitalShanghaiChina
| |
Collapse
|
11
|
Winther SS, Petersen M, Yilmaz M, Kaltoft NS, Stürup J, Winther NS. Custom-made triflanged implants in reconstruction of severe acetabular bone loss with pelvic discontinuity after total hip arthroplasty consecutive cohort study. Bone Jt Open 2022; 3:867-876. [DOI: 10.1302/2633-1462.311.bjo-2022-0101.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
Aims Pelvic discontinuity is a rare but increasingly common complication of total hip arthroplasty (THA). This single-centre study evaluated the performance of custom-made triflange acetabular components in acetabular reconstruction with pelvic discontinuity by determining: 1) revision and overall implant survival rates; 2) discontinuity healing rate; and 3) Harris Hip Score (HHS). Methods Retrospectively collected data of 38 patients (39 hips) with pelvic discontinuity treated with revision THA using a custom-made triflange acetabular component were analyzed. Minimum follow-up was two years (mean 5.1 years (2 to 11)). Results There were eight subsequent surgical interventions. Two failures (5%) of the triflange acetabular components were both revised because of deep infection. There were seven (18%) patients with dislocation, and five (13%) of these were treated with a constraint liner. One patient had a debridement, antibiotics, and implant retention (DAIR) procedure. In 34 (92%) hips the custom-made triflange component was considered stable, with a healed pelvic discontinuity with no aseptic loosening at midterm follow-up. Mean HHS was 80.5 (48 to 96). Conclusion The performance of the custom triflange implant in this study is encouraging, with high rates of discontinuity healing and osteointegration of the acetabular implant with no aseptic loosening at midterm follow-up. However, complications are not uncommon, particularly instability which we successfully addressed with constrained liners. Cite this article: Bone Jt Open 2022;3(11):867–876.
Collapse
Affiliation(s)
- Sebastian S. Winther
- Department of Orthopedic Surgery, Rigshospitalet University Hospital of Copenhagen, Copenhagen, Denmark
| | - Michael Petersen
- Department of Orthopedic Surgery, Rigshospitalet University Hospital of Copenhagen, Copenhagen, Denmark
| | - Müjgan Yilmaz
- Department of Orthopedic Surgery, Rigshospitalet University Hospital of Copenhagen, Copenhagen, Denmark
| | - Nicolai S. Kaltoft
- Department of Radiology, Rigshospitalet University Hospital of Copenhagen, Copenhagen, Denmark
| | - Jens Stürup
- Department of Orthopedic Surgery, Rigshospitalet University Hospital of Copenhagen, Copenhagen, Denmark
| | - Nikolaj S. Winther
- Department of Orthopedic Surgery, Rigshospitalet University Hospital of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
12
|
Wang Q, Wang Q, Liu P, Ge J, Zhang Q, Guo W, Wang W. Clinical and radiological outcomes of jumbo cup in revision total hip arthroplasty: A systematic review. Front Surg 2022; 9:929103. [PMID: 36268211 PMCID: PMC9577022 DOI: 10.3389/fsurg.2022.929103] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Accepted: 08/24/2022] [Indexed: 11/06/2022] Open
Abstract
Introduction Many studies have reported the clinical outcomes of a jumbo cup in revision total hip arthroplasty (rTHA) with acetabular bone defect. We conducted a systematic review to access the survivorship and clinical and radiological outcomes of a jumbo cup in rTHA. Methods A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A comprehensive literature search from PubMed, MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews was performed with the keywords (“revision” OR “revision surgery” OR “revision arthroplasty”) AND (“total hip arthroplasty” OR “total hip replacement” OR “THA” OR “THR”) AND (“jumbo cup” OR “jumbo component” OR “extra-large cup” OR “extra-large component”). Studies reporting the clinical or radiological outcomes were included. The basic information and radiological and clinical results of these studies were extracted and summarized for analysis. Results A total of 19 articles were included in the systematic review. The analysis of clinical results included 953 hips in 14 studies. The re-revision-free survivorship of the jumbo cup was 95.0% at a mean follow-up of 9.3 years. Dislocation, aseptic loosening, and periprosthetic joint infection were the top three complications with an incidence of 5.9%, 3.0%, and 2.1%, respectively. The postrevision hip center was relatively elevated 10.3 mm on average; the mean postoperative leg-length discrepancy was 5.4 mm. Conclusion A jumbo cup is a favorable option for acetabular bone defect reconstruction in rTHA with satisfying survivorship and acceptable complication rates.
Collapse
Affiliation(s)
- Qiuyuan Wang
- Graduate School, Beijing University of Chinese Medicine, Beijing, China,Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China
| | - Qi Wang
- Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China,Department of Orthopaedic Surgery, Peking University of China-Japan Friendship School of Clinical Medicine, Beijing, China
| | - Pei Liu
- Department of Adult Joint Reconstruction, Henan Luoyang Orthopedic Hospital (Henan Provincial Orthopedic Hospital), Zhengzhou, China
| | - Juncheng Ge
- Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China,Department of Orthopaedic Surgery, Peking University of China-Japan Friendship School of Clinical Medicine, Beijing, China
| | - Qidong Zhang
- Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China
| | - Wanshou Guo
- Graduate School, Beijing University of Chinese Medicine, Beijing, China,Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China,Correspondence: Weiguo Wang Wanshou Guo
| | - Weiguo Wang
- Department of Orthopaedic Surgery, China-Japan Friendship Hospital, Beijing, China,Correspondence: Weiguo Wang Wanshou Guo
| |
Collapse
|
13
|
Zhang Y, Ma H, Liu Y, Shen J, Zhang B, Zhou Y. The optimal screw-hole positions of the eccentric revision cup based on a morphological study. J Orthop Surg Res 2022; 17:386. [PMID: 35962392 PMCID: PMC9373531 DOI: 10.1186/s13018-022-03260-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 07/15/2022] [Indexed: 12/01/2022] Open
Abstract
Background Bridging bone defects in revision total hip arthroplasty is a challenge to orthopedic surgeons. The eccentric revision cup is a progression of jumbo cup. Our aim is to confirm the optimal screw-hole positions of the eccentric revision cup by morphological measurements of three-dimensional pelvic reconstruction.
Methods Eighty CT images were converted to virtual three-dimensional bones. After simulating the surgery procedure, all available screw holes were inserted with the screws in virtual. By measuring the length of the screw in the pelvic bone, we determined the rich bone stock area. Then the screw holes were designed according to the characteristics of bone stock distribution. The peripheral screw-hole cluster and inner screw-hole cluster were studied respectively. Results For peripheral screw-hole cluster, five screw holes were evenly distributed between point A and point B in the thicker rim. For inner screw-hole cluster, screw hole 1 and screw hole 2 are the recommended inner screw holes. Conclusion The eccentric revision cup has inherited the strengths of jumbo cup besides several unique advantages, including using the peripheral screws enhancing primary stability; decreasing the shift of hip rotation center and restoring biomechanical function; reducing the risk of dislocation because of the smaller head-cup differences; increasing the contact area between the outer cup and the host bone while maintaining a normal inclination of the inner cup. In this study, we confirmed the optimal screw-hole positions of the eccentric revision cup by surgical simulation and morphological measurement. However, biomechanical tests are still being further explored.
Collapse
Affiliation(s)
- Yanchao Zhang
- Department of Orthopedics, The First Medical Center of PLA General Hospital, Beijing, 100048, China.,Medical School of Chinese PLA, Beijing, 100853, China.,Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, 100048, China
| | - Haiyang Ma
- Department of Orthopedics, The First Medical Center of PLA General Hospital, Beijing, 100048, China
| | - Yang Liu
- Medical School of Chinese PLA, Beijing, 100853, China.,Medical School of Nankai University, Tianjin, 300071, China
| | - Junmin Shen
- Medical School of Chinese PLA, Beijing, 100853, China.,Medical School of Nankai University, Tianjin, 300071, China
| | - Bohan Zhang
- Department of Orthopedics, The First Medical Center of PLA General Hospital, Beijing, 100048, China.,Medical School of Chinese PLA, Beijing, 100853, China.,Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, 100048, China
| | - Yonggang Zhou
- Department of Orthopedics, The First Medical Center of PLA General Hospital, Beijing, 100048, China. .,Medical School of Chinese PLA, Beijing, 100853, China. .,Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, 100048, China.
| |
Collapse
|
14
|
The application of custom-made 3D-printed titanium augments designed through surgical simulation for severe bone defects in complex revision total hip arthroplasty. J Orthop Traumatol 2022; 23:37. [PMID: 35932367 PMCID: PMC9357241 DOI: 10.1186/s10195-022-00656-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 07/12/2022] [Indexed: 11/23/2022] Open
Abstract
Background With the development of radiology and three-dimensional (3D) printing technology, custom-made 3D-printed titanium augments have been more widely used. However, the radiological and clinical outcomes of custom-made augments lack reports. To better understand the clinical effect of using 3D-printed titanium augments and the significance of accurate placement, the aim of this study was to assess the outcomes when using custom-made 3D-printed titanium augments and to validate the idea that surgical simulation should be done before designing custom-made augments. Methods A retrospective review was conducted on 31 surgical simulations and revision total hip arthroplasties using custom-made 3D-printed titanium augments. The safe zone, cup position, and hip rotation center were measured on anteroposterior radiographs. Clinical outcomes were assessed with a mean 21.1 months of follow-up. Results All patients were positioned within the safe zone, and none of the acetabular cups nor the custom-made augments had any evidence of migration at the latest follow-up. A strong correlation was found between the planned cup position and the postoperative position. The average vertical position of the center of rotation was significantly increased from 3.55 cm to 2.35 cm. The mean Harris Hip Score was increased from 40.81 preoperatively to 65.46 postoperatively. Complications included gait abnormality, groin pain, fracture of the greater trochanter, and partial palsy of the sciatic nerve. However, patient satisfaction reached 92.3%. Conclusion Surgical simulations help to design custom-made augments accurately and improve surgical plans. Acetabular components supported with custom-made 3D-printed augments is a useful method to bridge severe bone deficiencies. In this study, both the radiologic results and clinical outcomes were favorable. Level of evidence Level 4. Supplementary Information The online version contains supplementary material available at 10.1186/s10195-022-00656-5.
Collapse
|
15
|
Rohe S, Dörr N, Böhle S, Matziolis G, Brodt S, Röhner E. Mid-term results in revision hip arthroplasty with impaction bone grafted cup reconstruction for acetabular defects. Sci Rep 2022; 12:13322. [PMID: 35922465 PMCID: PMC9349309 DOI: 10.1038/s41598-022-17526-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 07/26/2022] [Indexed: 11/25/2022] Open
Abstract
Acetabular defects are a challenging condition for surgeons in revision THA. A crucial aim is an anatomical restoration of the centre of rotation (COR) through grafts. The aim of this study was to determine the cup survival after biological restoration of acetabular defects in THA and the effect of Paprosky classification, age, BMI, and number of previous operations on cup survival. Retrospectively patients with a cup exchange and an impaction of cortico-cancellous or bulk grafts between 2009 and 2012 were included with a follow up with a minimum of 5 year. Implant failure was defined as radiographic loosening or explantation of the cup. The acetabular defect situation was classified to Paprosky. 82 patients (58 female 70.7%) were included. 26 patients were not available to contact. 56 patients (40 female 71.4%) remained for survival analysis with mean age of 75.6 ± 8 years. Survival of the cup after 5 years was 90% and after 7.8 years 88%. There was no difference in survival concerning defect classification, type of implant or graft, age, BMI, and number of previous operations. Patients on the follow up reached an HHS of 67.4 ± 19, a WOMAC Score of 33.4 ± 25.4 points and an unsatisfactory result in the SF-36. Impaction bone grafting of acetabular defects is a good option with satisfactory biomechanical results and survival for small defects. Predictive factors for cup survival could not be clarified in our study. So, the correct indication, knowing the limits of the methods and the correct choice of implant allow a defect-oriented approach and are decisive for the success of the operation.
Collapse
Affiliation(s)
- Sebastian Rohe
- Orthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, Campus Waldkliniken Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
| | - Nicoletta Dörr
- Orthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, Campus Waldkliniken Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| | - Sabrina Böhle
- Orthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, Campus Waldkliniken Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| | - Georg Matziolis
- Orthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, Campus Waldkliniken Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| | - Steffen Brodt
- Orthopaedic Department of the Waldkliniken Eisenberg, Orthopaedic Professorship of the University Hospital Jena, Campus Waldkliniken Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany
| | - Eric Röhner
- Orthopaedic Department of the Heinrich-Braun-Hospital Zwickau, 08060, Zwickau, Germany
| |
Collapse
|
16
|
Acetabular Peri-Prosthetic Fractures—A Narrative Review. Medicina (B Aires) 2022; 58:medicina58050630. [PMID: 35630047 PMCID: PMC9143047 DOI: 10.3390/medicina58050630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 04/25/2022] [Accepted: 04/27/2022] [Indexed: 12/15/2022] Open
Abstract
Acetabular peri-prosthetic fractures are rare but their incidence is rising due to the increased prevalence of total hip arthroplasty, the increasing life expectancy and the growing functional demand of an ageing population, the incidence of primary total hip arthroplasty is increasing. They are either intra-operative or post-operative and have various aetiologies. Several factors such as implant stability, bone loss, remaining bone stock, fracture pattern, timing, age and co-morbidities of the patients must be considered for adequate treatment. To date, the literature on this subject has been sparse and no universally recognized treatment algorithm exists. Their rarity makes them a little-known entity and their surgical management represents a challenge for most orthopaedic surgeons. This review aims to present an update on epidemiology, the diagnostic work up, existing classification systems, surgical approaches and therapeutic options for acetabular peri-prosthetic fractures.
Collapse
|
17
|
Malahias MA, Mancino F, Gu A, Adriani M, De Martino I, Boettner F, Sculco PK. Acetabular impaction grafting with mesh for acetabular bone defects: a systematic review. Hip Int 2022; 32:185-196. [PMID: 33147103 DOI: 10.1177/1120700020971851] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION In conjunction with impaction bone grafting (IBG), metal meshes have been proposed to minimise defects of the medial and superolateral walls in order to convert combined complex uncontained segmental defects into contained cavitary defects to facilitate IBG. METHODS The US National Library of Medicine (PubMed/MEDLINE), EMBASE, and the Cochrane Database of Systematic Reviews were queried for publications from January 1980 to March 2019 utilising keywords pertinent to total hip arthroplasty (THA), acetabular impaction bone grafting, clinical or functional outcomes, revision THA, or postoperative complications. RESULTS 7 articles were found to be suitable for inclusion in the present study. The mean modified Coleman methodology score for methodological deficiencies of the studies was 45.3 (range 38-59). Severe acetabular bone loss was present in 56% of cases having moderate bone loss in 18%, and mild in 26%. The all-cause reoperation rate was 7.4%, while the all-cause revision rate of the acetabular component was 6.2%. CONCLUSIONS IBG with mesh is effective for selected patients with acetabular bone defects. Most patients with moderate bone loss as well as selected patients with large superolateral defects can be successfully treated with IBG combined with mesh. There is limited data to show that IBG with mesh might be associated with decreased survival rates in patients with severe lateral defects (Paprosky IIIA) combined with ischial or medial wall osteolysis who require combined medial and lateral meshes. In addition, patients with severe superomedial migration of the cup (Paprosky IIIB) should not be treated with IBG and mesh.
Collapse
Affiliation(s)
- Michael-Alexander Malahias
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| | - Fabio Mancino
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| | - Alex Gu
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| | - Marco Adriani
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| | - Ivan De Martino
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| | - Friedrich Boettner
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| | - Peter K Sculco
- The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York, USA
| |
Collapse
|
18
|
Tikhilov RM, Dzhavadov AA, Kovalenko AN, Bilyk SS, Denisov AO, Shubnyakov II. Standard Versus Custom-Made Acetabular Implants in Revision Total Hip Arthroplasty. J Arthroplasty 2022; 37:119-125. [PMID: 34598861 DOI: 10.1016/j.arth.2021.09.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/24/2021] [Accepted: 09/01/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Today, various options are used for the reconstruction of acetabular bone loss in revision total hip arthroplasty (RTHA). The aim of the study was to compare the outcomes of using standard acetabular implants (SAIs) and custom-made acetabular implants (CMAIs) in RTHA in cases with extensive acetabular bone loss. METHODS This was a comparative analysis of the results of 106 operations of RTHA performed during the period from January 2013 to December 2019. In 61 cases (57.5%), CMAIs were used. In 45 cases (42.5%), SAIs were implanted. RESULTS The incidence of aseptic loosening of the acetabular component after RTHA in uncontained loss of bone stock of the acetabulum (type III-IV as per the Gross and Saleh classification) using the CMAI was less than that using the SAI (2.4% and 10.0%, respectively). The most significant differences in aseptic loosening rates were noted after implantation of the CMAI and SAI in pelvic discontinuity with uncontained bone defect (0% and 60.0%, respectively; P<.001). CONCLUSION The ideal indications for the use of the CMAI are uncontained defects and pelvic discontinuity with uncontained loss of bone stock (types III-V Gross and Saleh classification). Treatment of these defects with the SAI leads to a higher incidence of aseptic loosening requiring re-revisions. Further observation is required to assess the effectiveness of using the CMAI and SAI in the long-term follow-up period.
Collapse
Affiliation(s)
- Rashid M Tikhilov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Alisagib A Dzhavadov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Anton N Kovalenko
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Stanislav S Bilyk
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Alexey O Denisov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| | - Igor I Shubnyakov
- Vreden National Medical Research Center of Traumatology and Orthopedics, Ministry of Health of Russian Federation, St. Petersburg, Russian Federation
| |
Collapse
|
19
|
Peng YW, Shen JM, Zhang YC, Sun JY, Du YQ, Zhou YG. Jumbo cup in hip joint renovation may cause the center of rotation to increase. World J Clin Cases 2021; 9:6300-6307. [PMID: 34434996 PMCID: PMC8362550 DOI: 10.12998/wjcc.v9.i22.6300] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Revised: 05/24/2021] [Accepted: 05/27/2021] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Utilizing the large jumbo cup in revision total hip arthroplasty is an effective approach to cure many lacunar and segmental peripheral bone defects. However, with the use of the jumbo cup, the center of the hip joint may become elevated relative to the primary acetabulum, and the diameter of the large cup is greater.
AIM To study the height and the significance of the elevation of the hip joint center.
METHODS Eighty-eight patients matched the criteria for this condition and were included in the study. The center height of the hip joint was measured relative to the opposite normal hip joint. The diameter of the jumbo cup was measured and checked according to operation notes, and the diameter of the jumbo cup was measured with a prosthesis label. Then, the horizontal and vertical centers of rotation were measured on the surgical side and opposite side. The average center height of the hip joint on the renovated side and the opposite side and the position of the hip cup relative to the teardrop were compared using a paired t-test.
RESULTS Radiometric analysis showed that the average hip joint center was elevated by 7.6 mm. The rotational center height delta of the renovated hip was 7.6 ± 5.6 mm, and there was an obvious difference between the two groups (P = 0.00). The difference in horizontal distance was 0.5 ± 5.1 mm (-11.5 -14.0 mm), and there was no obvious difference between the two groups (P = 0.38). According to the foreign standard, the rotational center height delta of the renovated hip was 7.5 ± 6.2 mm, and there was a significant difference between the two groups (P = 0.00). There was no obvious difference between the domestic and foreign standards (P > 0.05) between the two groups.
CONCLUSION The application of the jumbo cup elevates the rotational center of the hip joint, but it is feasible and effective to use the jumbo cup.
Collapse
Affiliation(s)
- Ya-Wen Peng
- Department of Orthopedics, The First Medical Centre, Chinese People’s Liberation Army General Hospital, Beijing 100853, China
| | - Jun-Min Shen
- Department of Orthopedics, The First Medical Centre, Chinese People’s Liberation Army General Hospital, Beijing 100853, China
| | - Yan-Chao Zhang
- Department of Orthopedics, The First Medical Centre, Chinese People’s Liberation Army General Hospital, Beijing 100853, China
| | - Jing-Yang Sun
- Department of Orthopedics, The First Medical Centre, Chinese People’s Liberation Army General Hospital, Beijing 100853, China
| | - Yin-Qiao Du
- Department of Orthopedics, The First Medical Centre, Chinese People’s Liberation Army General Hospital, Beijing 100853, China
| | - Yong-Gang Zhou
- Department of Orthopedics, The First Medical Centre, Chinese People’s Liberation Army General Hospital, Beijing 100853, China
| |
Collapse
|
20
|
Kawalkar AC, Kalanie A, Neil MJ. Excellent Midterm Results of Triflange Patient Matched Implants for Extensive Acetabular Bone Defect. Hip Pelvis 2021; 33:87-95. [PMID: 34141695 PMCID: PMC8190502 DOI: 10.5371/hp.2021.33.2.87] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 09/22/2020] [Accepted: 10/13/2020] [Indexed: 11/30/2022] Open
Abstract
Purpose Reconstruction of extensive acetabular bone defects is one of the most challenging problems encountered by arthroplasty surgeons. Triflange patient matched implants (PMI) offer the potential advantages of immediate, rigid fixation with a superior individualized fit. The purpose of this study was to evaluate the clinical and radiographic midterm results of PMI in extensive acetabular defect reconstruction. Materials and Methods The current prospectively designed retrospective review examined 13 consecutive patients (5 males and 8 females) with a mean age of 69 years undergoing revision hip arthroplasty with Paprosky type 3B acetabular defects reconstructed using PMI between October 2011 and December 2016. A successful result was defined as a postoperative increase in Harris hip score (HHS) of >20 points with a radiographically stable implant (assessed with hip X-rays) and no need for additional acetabular reconstruction. Results Twelve out of the 13 patients in the study were available for follow-up with mean duration of 50 months. One patient died during the study period due to an unrelated cause. The mean HHS increased from 41 to 82 points. Eleven out of 12 acetabular components were well fixed and pelvic discontinuity healed in all patients. Conclusion Custom triflange PMI is an excellent option for management of complex and extensive acetabular defects with or without pelvic discontinuity.
Collapse
Affiliation(s)
- Abhijit C Kawalkar
- Department of Orthopedic Surgery, Orange City Hospital and Research Institute, Nagpur, India
| | - Amir Kalanie
- Department of Orthopedic Surgery, St. Vincent's Bone and Joint Unit, St. Vincent's Private Hospital Sydney, Darlinghurst, Sydney, Australia
| | - Micheal J Neil
- Department of Orthopedic Surgery, St. Vincent's Bone and Joint Unit, St. Vincent's Private Hospital Sydney, Darlinghurst, Sydney, Australia
| |
Collapse
|
21
|
Yun A, Qutami M, Pasko KB. Surgical Management of Iliopsoas Impingement With Combined Acetabular Revision and Partial Psoas Tenotomy. Cureus 2021; 13:e13193. [PMID: 33717735 PMCID: PMC7943055 DOI: 10.7759/cureus.13193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background Persistent groin pain after total hip arthroplasty (THA) can result from iliopsoas impingement (IPI) on the acetabular rim. Controversy exists over the risks and benefits of tenotomy versus revision as a surgical solution. We report our limited experience with combined acetabular revision and partial iliopsoas tenotomy when other conservative treatments have failed. Methodology A total of eight patients revised for IPI by a single surgeon at a single institution were retrospectively reviewed after a minimum one-year follow-up. Preoperatively, all patients had prolonged groin pain for a mean of two years (range: 1-4 years) and had failed conservative treatment for at least six months. All patients underwent acetabular revision through a direct anterior approach (DAA) with partial psoas tendon release. No stems were revised. Dislocations, complications, and clinical outcomes are reported in this study. Results Of the eight patients, seven had a positive diagnostic challenge with an image-guided injection. All revised cups showed radiographic evidence of IPI with relative acetabular retroversion by either a cross-table lateral film or computed tomography scan. Preoperatively, the mean cup anteversion was 4 degrees (range: 0-9 degrees). Postoperatively, the mean cup anteversion was 19 degrees (range: 16-21 degrees). All cups were within the so-called safe zone. To avoid overstuffing, the mean cup size remained unchanged. There were no major postoperative complications. At a mean time to follow-up of 3.3 years, the mean Hip disability and Osteoarthritis Outcome Score for Joint Replacement was 75 points (range: 32-100 points). Conclusion IPI may be effectively managed with combined acetabular revision and tenotomy. The challenges of implant placement and positioning may be aided with intraoperative imaging through a DAA THA.
Collapse
Affiliation(s)
- Andrew Yun
- Orthopaedic Surgery, Center for Hip and Knee Replacement, Providence Saint John's Health Center, Santa Monica, USA
| | - Marilena Qutami
- Orthopaedic Surgery, Center for Hip and Knee Replacement, Providence Saint John's Health Center, Santa Monica, USA
| | - Kory B Pasko
- Orthopaedic Surgery, Georgetown University School of Medicine, Georgetown Hospital, Washington, DC, USA
| |
Collapse
|
22
|
Mancino F, Cacciola G, Di Matteo V, De Marco D, Greenberg A, Perisano C, MA M, Sculco PK, Maccauro G, De Martino I. Reconstruction options and outcomes for acetabular bone loss in revision hip arthroplasty. Orthop Rev (Pavia) 2020; 12:8655. [PMID: 32913591 PMCID: PMC7459368 DOI: 10.4081/or.2020.8655] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 06/17/2020] [Indexed: 12/20/2022] Open
Abstract
Revision total hip arthroplasty in the setting of acetabular bone loss is a challenging procedure and requires a solid understanding of current acetabular reconstruction options. Despite major developments in the field of revision hip surgery in recent decades, reconstruction of acetabular defects remains a major problem in order to achieve primary stability and durable fixation without sacrificing additional bone stock. Although there are several ways to classify acetabular bone defects, the Paprosky classification system is the most commonly used to describe the defects and guide treatment strategy. An understanding of the bone defects associated with detailed pre-operative assessment and planning are essential elements in order to achieve satisfactory outcomes. Multiple acetabular reconstructive options are currently available including impaction bone grafting with metal mesh, reinforcement rings and antiprotrusio cage, structural allografts, cementless hemispherical cups, extra-large "jumbo cups", oblong cups, modular porous metal augments, cup-cage constructs, custom- made triflange cups, and acetabular distraction. To date, debate continues as to which technique is most effective due to the lack of long-term studies of modern reconstruction systems. Further long-term studies are necessary to assess the longevity of the different implants. The purpose of this study was to review the current literature and provide a comprehensive understanding of the available reconstruction options with their clinical outcomes.
Collapse
Affiliation(s)
- Fabio Mancino
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Giorgio Cacciola
- GIOMI Istituto Ortopedico del Mezzogiorno d’Italia Franco Scalabrino, Ganzirri, Messina, Italy
| | - Vincenzo Di Matteo
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Davide De Marco
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Alexander Greenberg
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY, USA
| | - Carlo Perisano
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Malahias MA
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY, USA
| | - Peter K. Sculco
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY, USA
| | - Giulio Maccauro
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
- Università Cattolica del Sacro Cuore, Rome, Italy
| | - Ivan De Martino
- Division of Orthopaedics and Traumatology, Department of Aging, Neurological, Orthopaedic and Head- Neck Studies, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Rome, Italy
| |
Collapse
|
23
|
Matar HE, Selvaratnam V, Shah N, Wynn Jones H. Custom triflange revision acetabular components for significant bone defects and pelvic discontinuity: Early UK experience. J Orthop 2020; 21:25-30. [PMID: 32071529 DOI: 10.1016/j.jor.2020.01.053] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Accepted: 01/31/2020] [Indexed: 10/25/2022] Open
Abstract
Aims We report our early experience in acetabular reconstruction for significant bone loss and pelvic discontinuity using custom triflange acetabular components. Patients and methods Retrospective consecutive review of all patients treated at our specialist tertiary unit with significant acetabular defects (Paprosky 3A/3B) and pelvic discontinuity who were reconstructed with custom triflange implants. The primary outcomes were radiographic failure and complications. Results 17 patients (17 hips) were included; 3 males/14 females with a mean age of 72 years (range 61-83). The average follow-up was 3.6 years (2-7 years). Bony defects were Paprosky 3B in 13/17 hips (76%) with pelvic discontinuity encountered in the majority of cases 15/17 hips (88%) and intra-pelvic failed components in 11/17 (64%). At final follow up, no radiographic failures were observed although three patients developed complications (17.6%); haematoma requiring washout out; intra-operative ilium fracture; and recurrent dislocation in one patient. Conclusions Our experience suggest that acceptable outcomes can be achieved with custom implants for this group of challenging patients, although longer follow up is needed to monitor future implants' failure.
Collapse
Affiliation(s)
- Hosam E Matar
- Centre for Hip Surgery, Wrightington Hospital, Wigan, WN6 9EP, United Kingdom
| | - Veenesh Selvaratnam
- Centre for Hip Surgery, Wrightington Hospital, Wigan, WN6 9EP, United Kingdom
| | - Nikhil Shah
- Centre for Hip Surgery, Wrightington Hospital, Wigan, WN6 9EP, United Kingdom
| | - Henry Wynn Jones
- Centre for Hip Surgery, Wrightington Hospital, Wigan, WN6 9EP, United Kingdom
| |
Collapse
|
24
|
Salem Eid A, Kotb A, Elshabrawy W. Cementless jumbo cups for revision of failed Furlong prosthesis. A case series. J Clin Orthop Trauma 2020; 11:56-61. [PMID: 32001985 PMCID: PMC6985161 DOI: 10.1016/j.jcot.2018.08.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2018] [Accepted: 08/02/2018] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND Revision of failed total hip arthroplasty (THA) presents great challenge to any orthopaedic surgeon especially in the presence of acetabular defects where the main goal is to achieve durable fixation of prosthetic components to bone which is the key to successful revision surgery. METHODS Seventeen patients (17 hips) with mean age of 52 (40-61) years had revision surgery for aseptic failure of Furlong hydroxyapatite-ceramic-coated (HAC) prosthesis using cementless jumbo cups. Patients were reviewed clinically and radiographically with mean follow-up of 3.5 years (2-6). No patient was lost to follow up. RESULTS All revised acetabular components showed polyethylene wear, severe metallosis, with acetabular defects IIB (4/17), and IIIA (13/17) according to Paprosky classification. The femoral component was well fixed in all cases but one patient had stem revision for femoral fracture mal-union. There was one early post-operative infection; there was no postoperative dislocation, sciatic nerve injury, periprosthetic fracture or deep venous thrombosis. At last follow-up, no progressive radiolucencies or acetabular migration was identified. The mean Harris hip score improved from 42 (24-59) pre-operatively to 85 (72-92). CONCLUSION Good clinical results and radiographic stability were obtained at short term follow up after acetabular revision using cementless jumbo cups, which justify its use in revision surgery even in the face of major acetabular defects. Furlong HAC femoral component gives excellent long-term survival in young and active patients with a survival rate of 94% at 18.6 years.
Collapse
|
25
|
De Martino I, Strigelli V, Cacciola G, Gu A, Bostrom MP, Sculco PK. Survivorship and Clinical Outcomes of Custom Triflange Acetabular Components in Revision Total Hip Arthroplasty: A Systematic Review. J Arthroplasty 2019; 34:2511-2518. [PMID: 31213338 DOI: 10.1016/j.arth.2019.05.032] [Citation(s) in RCA: 57] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 04/30/2019] [Accepted: 05/16/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Several studies have evaluated the survivorship and clinical outcomes of custom triflange acetabular component (CTAC) usage in complex acetabular revision; however, there remains no consensus on the overall performance of this custom implant design. We therefore performed a systematic review of the literature in order to examine survivorship and complication rate of CTAC usage. METHODS A systematic review of the literature according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was performed. A comprehensive search of PubMed, MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews was conducted for English articles using various combinations of the keywords "custom triflange," "custom-made triflange," "acetabular triflange," "THA," "THR," "revision," "bone loss," "bone defect," and "pelvic discontinuity." RESULTS In all, 17 articles met our inclusion criteria. A total of 579 CTACs were implanted. The all-cause revision-free survivorship was 82.7%. The overall complication rate was 29%. Dislocation and infection were the most common complications observed with an incidence of 11% and 6.2%, respectively. Nerve injuries following CTAC placement had an incidence of 3.8%. The incidence of CTAC aseptic loosening was 1.7%. Overall, patients had improved outcomes as documented by postoperative hip scores. CONCLUSION Based on the current data, CTACs have a high complication rate but remain an efficacious treatment option in complex acetabular reconstructions. When dealing with patients with significant acetabular bone loss for revision total hip arthroplasty, surgeons should continue to consider CTACs as a viable option but educate patients as to the increased risk of postoperative complications and reoperations.
Collapse
Affiliation(s)
- Ivan De Martino
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Vanni Strigelli
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Giorgio Cacciola
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Alex Gu
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Mathias P Bostrom
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| | - Peter K Sculco
- Stavros Niarchos Foundation Complex Joint Reconstruction Center, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY
| |
Collapse
|
26
|
Abdelnasser MK, Khalifa AA, Mahran MA, Mosa M, Bakr HM, Khalifa YE, Abdelaal AM. Post-operative hip centre restoration and migration after impaction bone grafting in revision and complex primary hip arthroplasty. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2019; 29:1411-1417. [PMID: 31161240 DOI: 10.1007/s00590-019-02458-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 05/29/2019] [Indexed: 10/26/2022]
Abstract
INTRODUCTION/OBJECTIVES Although impaction grafting proved efficacy in the reconstruction of acetabular defects in primary and revision hip arthroplasty, its role in large segmental defects is still debatable. Our objective is to determine hip centre restoration and last follow-up migration after acetabular reconstruction with impaction grafting in different types of acetabular defects. METHODS This is a single-centre retrospective radiographic study of (107) total hip arthroplasty (42 primary and 65 revision) in (104) patients using impaction grafting. The available radiographs were examined for normal, preoperative, immediate postoperative, and last follow-up vertical (Y) and horizontal (X) hip centre. Maximum acetabular defect distance (MADD), presence, and size of the mesh were recorded. RESULTS In type I and II AAOS defects, the post-operative hip centre was not significantly different from the normal hip centre on the contralateral healthy side. In type III defects, there was a significant variation between the normal hip centre and the post-operative hip centre (P value 0.034 and 0.001 for Y and X, respectively). At 44-month follow-up of 36 hips, 31 (86%) hips migrated. The mean migration ± SD was 5.72 ± 3.7, 2, 4.15 ± 1.2, and 11.26 ± 3.9 mm for types I, II, and III, respectively (P value 0.211). Hips with MADD > 15 mm, especially with large mesh sizes migrate significantly more (P value = 0.042, 0.037, and 0.039, respectively). CONCLUSION Hip centre restoration was better, and migration was less for type I and II AAOS rather than for type III. Other options for reconstruction should be considered.
Collapse
Affiliation(s)
| | - Ahmed A Khalifa
- Orthopaedic and Traumatology Department, Assuit University Hospital, Assuit, Egypt.
- Orthopaedic and Traumatology Department, Qena University Hospital, Qena, Egypt.
| | - Mohammad A Mahran
- Orthopaedic and Traumatology Department, Assuit University Hospital, Assuit, Egypt
| | - Mohamed Mosa
- Orthopaedic and Traumatology Department, Al-Azhar University, Assuit Branch, Assuit, Egypt
| | - Hatem M Bakr
- Orthopaedic and Traumatology Department, Assuit University Hospital, Assuit, Egypt
| | - Yaser E Khalifa
- Orthopaedic and Traumatology Department, Assuit University Hospital, Assuit, Egypt
| | - Ahmed M Abdelaal
- Orthopaedic and Traumatology Department, Assuit University Hospital, Assuit, Egypt
| |
Collapse
|
27
|
Tamaki T, Ninomiya T, Jonishi K, Miura Y, Oinuma K, Shiratsuchi H. Acetabular revision using a Kerboull-type reinforcement device through direct anterior approach. J Orthop Surg (Hong Kong) 2019; 26:2309499018782553. [PMID: 29945476 DOI: 10.1177/2309499018782553] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
BACKGROUND The direct anterior approach has gained popularity in total hip arthroplasty (THA) over the past decade. However, there are few reports that describe the use of this approach for cases of complex revision. The purpose of this study was to report the surgical procedure and early clinical results of acetabular revision in the presence of bone defects using a Kerboull-type reinforcement device through the direct anterior approach. METHODS Eleven patients who had undergone acetabular reconstruction using a Kerboull-type reinforcement device for aseptic or septic loosening bone defects were enrolled. All procedures were performed using the direct anterior approach on a standard operating table. The mean age was 71.8 years, the mean period from initial surgery to revision THA was 14.5 years, and the mean follow-up period was 19.8 months. RESULTS The Kerboull-type acetabular reinforcement device with cemented cup combined with allogenic femoral head bone grafts was used in all hips. The mean operative time and intraoperative blood loss were 148 min and 743 g, respectively. None of the patients required allogeneic blood transfusion. One patient required revision surgery 11 months postoperatively because of device displacement. No other major or minor orthopedic complications were observed. CONCLUSION The direct anterior approach allows for less invasive acetabular reconstruction using a Kerboull-type reinforcement device.
Collapse
Affiliation(s)
- Tatsuya Tamaki
- Joint Reconstruction Center, Funabashi Orthopedic Hospital, Chiba, Japan
| | - Taishi Ninomiya
- Joint Reconstruction Center, Funabashi Orthopedic Hospital, Chiba, Japan
| | - Kurato Jonishi
- Joint Reconstruction Center, Funabashi Orthopedic Hospital, Chiba, Japan
| | - Yoko Miura
- Joint Reconstruction Center, Funabashi Orthopedic Hospital, Chiba, Japan
| | - Kazuhiro Oinuma
- Joint Reconstruction Center, Funabashi Orthopedic Hospital, Chiba, Japan
| | | |
Collapse
|
28
|
Zhang J, Huang Y, Zhou B, Zhou Y. Mid-Term Follow-Up of Acetabular Revision Arthroplasty Using Jumbo Cups. Orthop Surg 2019; 11:811-818. [PMID: 31549788 PMCID: PMC6819183 DOI: 10.1111/os.12522] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2019] [Revised: 07/15/2019] [Accepted: 07/28/2019] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVE To evaluate the mid-term clinical and radiographic results of revision total hip arthroplasty (THA) using jumbo cups in Chinese patients. METHODS We retrospectively studied 61 patients (63 hips; 29 men [30 hips], 32 women [33 hips]) who underwent acetabular revision with jumbo cups between January 2001 and April 2016 at our institution. The mean age at the index operation was 59.4 ± 11.4 years. The mean body mass index of the patients was 24.9 ± 3.8 kg/m2 . Clinical evaluation was determined using the Harris hip score preoperatively and at follow up. Major complications (including instability, sepsis, and revision of the femoral or acetabular component) were recorded. Radiographic measurements included inclination and anteversion angles of the acetabular components, and the vertical and horizontal distances of the centers of rotation (V-COR and H-COR, respectively). In the 42 patients with normal contralateral hip joints, the postoperative V-COR and H-COR were compared between right and left sides. Their improvement in leg-length discrepancy (LLD) after revision THA was also evaluated. Cup survival was evaluated using the Kaplan-Meier analysis. Clinical and radiographic outcomes were analyzed. RESULTS Mean follow up was 5.7 years (2-16 years). At the latest follow-up, the average Harris hip score (preoperative vs postoperative values) had improved from 46 to 83 (P < 0.001). No acetabular component was radiographically defined as loosened. Four hips (6.3%) had major complications: one hip was revised because of periprosthetic infection (at 3 months); one underwent femoral open reduction and internal fixation (with implant retention) because of a periprosthetic femoral fracture (at 13 months); one operated hip developed a deep infection (at 2.5 years), which was treated with antibiotics; one hip experienced recurrent dislocation (at 4.5 years). The average cup inclination angle was 40.8° ± 6.8° and the average anteversion angle was 14.9° ± 6.6°. Average V-COR decreased from 29.7 ± 10.4 mm to 22.3 ± 7.6 mm (P < 0.001). The average postoperative H-COR was 29.5 ± 3.7 mm compared with 30.8 ± 6.6 mm preoperatively (P = 0.145). Among the 42 patients with normal contralateral hips, the average postoperative V-COR were 22.2 ± 8.3 mm (operated side) and 14.0 ± 3.7 mm (contralateral side) (P < 0.001). LLD improved from -16.8 ± 17.1 mm to -5.6 ± 11.8 mm (P < 0.001). When failure was defined as any reoperation involving the hip, the mean 16-year hip survival was 96.8% (95% confidence interval [CI] 87.9%-99.2%). When defined as any hip reoperation or major complication, it was 92.7% (95%CI 81.2%-97.2%). CONCLUSION Use of jumbo cups for revision THA resulted in excellent mid-term cup survival and helped restore the COR.
Collapse
Affiliation(s)
- Ji Zhang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yong Huang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Baochun Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| |
Collapse
|
29
|
Acetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up study. Arch Orthop Trauma Surg 2019; 139:1149-1160. [PMID: 31187257 DOI: 10.1007/s00402-019-03214-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2018] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Acetabular revision arthroplasty using jumbo cups for moderate-to-severe acetabular defects has varied outcomes. We evaluated the clinical and radiological outcomes of acetabular revision arthroplasty using a press-fitted jumbo cup and sought to identify factors that influence outcomes during intermediate follow-up. MATERIALS AND METHODS Eighty patients (47 men, 33 women; 80 hips) who underwent acetabular revision arthroplasty using press-fitted jumbo cups were included. The mean follow-up period was 10.4 years. Harris hip score (HHS), presence of groin pain, radiographic results, and Kaplan-Meier survival curves were evaluated. Implant design and surgery-related and patient-related factors were assessed to identify influential factors for cup loosening. Migration and wear analyses were performed using Einzel-Bild-Röntgen-Analyse software. RESULTS The mean preoperative HHS of 53 had improved to 77 at the final follow-up (p = 0.005). Nine patients experienced groin pain. Acetabular cup loosening was observed in seven cups (8.7%), and one jumbo cup was replaced with a reinforcement cage. The survival rate of the acetabular cup was 91% at 16 years according to the Kaplan-Meier analysis. Osteolysis was identified around the cup in six cases (7.5%). Acetabular cup loosening occurred more frequently in patients with conventional polyethylene liners than in those with highly cross-linked polyethylene liners (p = 0.045). The mean total migration was 1.52 mm, and the mean total wear was 0.98 mm. There was a positive correlation between total migration and total wear (p = 0.023; Spearman's rho = 0.388). The mean wear rate of the patients with the cup inclination angle < 50° was significantly lower than those with the cup inclination angle > 50° (p = 0.001). There were four cases of complications (three dislocations and one infection) that did not require revision surgery. CONCLUSION Press-fitted jumbo cups for acetabular revision arthroplasty exhibited encouraging results during follow-up for an average of 10 years. Use of highly cross-linked polyethylene liners and proper placement of the acetabular component with an inclination angle < 50° may contribute to better clinical outcomes after acetabular revision arthroplasty with jumbo cups.
Collapse
|
30
|
Jones CW, Choi DS, Sun P, Chiu YF, Lipman JD, Lyman S, Bostrom MPG, Sculco PK. Clinical and design factors influence the survivorship of custom flange acetabular components. Bone Joint J 2019; 101-B:68-76. [PMID: 31146558 DOI: 10.1302/0301-620x.101b6.bjj-2018-1455.r1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Custom flange acetabular components (CFACs) are a patient-specific option for addressing large acetabular defects at revision total hip arthroplasty (THA), but patient and implant characteristics that affect survivorship remain unknown. This study aimed to identify patient and design factors related to survivorship. PATIENTS AND METHODS A retrospective review of 91 patients who underwent revision THA using 96 CFACs was undertaken, comparing features between radiologically failed and successful cases. Patient characteristics (demographic, clinical, and radiological) and implant features (design characteristics and intraoperative features) were collected. There were 74 women and 22 men; their mean age was 62 years (31 to 85). The mean follow-up was 24.9 months (sd 27.6; 0 to 116). Two sets of statistical analyses were performed: 1) univariate analyses (Pearson's chi-squared and independent-samples Student's t-tests) for each feature; and 2) bivariable logistic regressions using features identified from a random forest analysis. RESULTS Radiological failure and revision rates were 23% and 12.5%, respectively. Revisions were undertaken at a mean of 25.1 months (sd 26.4) postoperatively. Patients with radiological failure were younger at the time of the initial procedure, were less likely to have a diagnosis of primary osteoarthritis (OA), were more likely to have had ischial screws in previous surgery, had fewer ischial screw holes in their CFAC design, and had more proximal ischial fixation. Random forest analysis identified the age of the patient and the number of locking and non-locking screws used for inclusion in subsequent bivariable logistic regression, but only age (odds ratio 0.93 per year) was found to be significant. CONCLUSION We identified both patient and design features predictive of CFAC survivorship. We found a higher rate of failure in younger patients, those whose primary diagnosis was not OA, and those with more proximal ischial fixation or fewer ischial fixation options. Cite this article: Bone Joint J 2019;101-B(6 Supple B):68-76.
Collapse
Affiliation(s)
- C W Jones
- Hospital for Special Surgery, New York City, New York, USA
| | - D S Choi
- Hospital for Special Surgery, New York City, New York, USA
| | - P Sun
- Hospital for Special Surgery, New York City, New York, USA
| | - Y-F Chiu
- Hospital for Special Surgery, New York City, New York, USA
| | - J D Lipman
- Hospital for Special Surgery, New York City, New York, USA
| | - S Lyman
- Hospital for Special Surgery, New York City, New York, USA
| | - M P G Bostrom
- Hospital for Special Surgery, New York City, New York, USA
| | - P K Sculco
- Hospital for Special Surgery, New York City, New York, USA
| |
Collapse
|
31
|
Zhou B, Zhou Y, Yang D, Tang H, Shao H, Huang Y. The Utilization of Metal Augments Allows Better Biomechanical Reconstruction of the Hip in Revision Total Hip Arthroplasty With Severe Acetabular Defects: A Comparative Study. J Arthroplasty 2018; 33:3724-3733. [PMID: 30243881 DOI: 10.1016/j.arth.2018.08.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 08/22/2018] [Accepted: 08/24/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Reconstructing the normal hip biomechanics is important for a successful revision total hip arthroplasty (THA). Little is known about whether using metal augments in revision THA is biomechanically superior to traditional techniques. METHODS A retrospective review was conducted on 74 consecutive THAs revised using metal augments with a cementless hemispherical cup and 77 consecutive THAs revised using the jumbo cup, all with a minimum 2-year follow-up. Biomechanical parameters were measured before and immediately after the revision. Radiological and clinical outcomes at follow-ups were also evaluated. RESULTS The metal augment group had a reconstructed center of rotation (COR) that was 6.5 mm closer to the anatomic COR in height (P < .001), had 3.6 m smaller cup size (P < .001), and had 5.7 mm less head-cup difference (P < .001). Moreover, there was a reconstructed COR that was much closer to the anatomic COR (vertical distance: 1.8 vs 14.1 mm, P < .001; horizontal distance: -2.1 vs 7.9 mm, P = .013), had 4.1 mm greater femoral offset (P = .006), and had 8 mm less leg length discrepancy (P = .035) in the subgroup of Paprosky type III bone defects when compared to the jumbo cup group. All cup-augment constructs were radiologically stable with a higher mean postoperative Harris Hip Score (P = .012). One jumbo cup was radiologically unstable. CONCLUSION In revision THA, utilizing metal augments helps to restore the COR position more precisely, avoid using a larger cup, reduce head-cup difference, rebuild femoral offset, and decrease leg length discrepancy, particularly with Paprosky type III bone defects. Moreover, it provides satisfactory radiological and clinical outcomes in the short term.
Collapse
Affiliation(s)
- Baochun Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Dejin Yang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Hao Tang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Hongyi Shao
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| | - Yong Huang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, People's Republic of China
| |
Collapse
|
32
|
Green CM, Buckley SC, Hamer AJ, Kerry RM, Harrison TP. Long-term results of acetabular reconstruction using irradiated allograft bone. Bone Joint J 2018; 100-B:1449-1454. [PMID: 30418060 DOI: 10.1302/0301-620x.100b11.bjj-2018-0478.r2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
AIMS The management of acetabular defects at the time of revision hip arthroplasty surgery is a challenge. This study presents the results of a long-term follow-up study of the use of irradiated allograft bone in acetabular reconstruction. PATIENTS AND METHODS Between 1990 and 2000, 123 hips in 110 patients underwent acetabular reconstruction for aseptic loosening, using impaction bone grafting with frozen, irradiated, and morsellized femoral heads and a cemented acetabular component. A total of 55 men and 55 women with a mean age of 64.3 years (26 to 97) at the time of revision surgery are included in this study. RESULTS At a mean follow-up of 16.9 years, there had been 23 revisions (18.7%), including ten for infection, eight for aseptic loosening, and three for dislocation. Of the 66 surviving hips (58 patients) that could be reassessed, 50 hips (42 patients; 75.6%) were still functioning satisfactorily. Union of the graft had occurred in all hips with a surviving implant. Survival analysis for all indications was 80.6% at 15 years (55 patients at risk, 95% confidence interval (CI) 71.1 to 87.2) and 73.7% at 20 years (eight patients at risk, 95% CI 61.6 to 82.5). CONCLUSION Acetabular reconstruction using frozen, irradiated, and morsellized allograft bone and a cemented acetabular component is an effective method of treatment. It gives satisfactory long-term results and is comparable to other types of reconstruction. Cite this article: Bone Joint J 2018;100-B:1449-54.
Collapse
Affiliation(s)
- C M Green
- Golden Jubilee National Hospital, Glasgow, UK
| | - S C Buckley
- Lower Limb Arthroplasty Unit, Northern General Hospital, Sheffield, UK
| | - A J Hamer
- Lower Limb Arthroplasty Unit, Northern General Hospital, Sheffield, UK
| | - R M Kerry
- Lower Limb Arthroplasty Unit, Northern General Hospital, Sheffield, UK
| | - T P Harrison
- Lower Limb Arthroplasty Unit, Northern General Hospital, Sheffield, UK
| |
Collapse
|
33
|
Kieser DC, Ailabouni R, Kieser SCJ, Wyatt MC, Armour PC, Coates MH, Hooper GJ. The use of an Ossis custom 3D-printed tri-flanged acetabular implant for major bone loss: minimum 2-year follow-up. Hip Int 2018; 28:668-674. [PMID: 29783895 DOI: 10.1177/1120700018760817] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Custom 3D-printed acetabular implants are a new technology used in hip surgery with ever-increasing frequency. They offer patient-specific implants to optimise filling of bone defects and implant-bone contact, without the need for excessive bone resection. METHODS This is a retrospective cohort study of 46 consecutive patients who underwent an Ossis unilateral custom 3D-printed acetabular implant. Clinical (Oxford Hip Score OHS-60), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Harris Hip Score (HHS) and radiological (restoration of biomechanical hip centre, osteointegration, wear, heterotrophic ossification) results were assessed. RESULTS Patient mean age was 68 years and follow-up was 38 months (minimum 24 months). 10 patients were excluded from the outcome analysis; 2 patients died, 1 required revision for deep infection and 7 were lost to follow-up. Of the 36 patients included, 21 had severe osteolysis. 7 were revised for infection, 3 for tumoural defects, 3 for metallosis, 1 for dysplasia and 1 for trauma (Paprosky 2a [n=6], 2b [n=2], 2c [n=5], 3a [n=6], 3b [n=11], pelvic dissociation [n=6]). OHS significantly improved postoperatively (16-8-48.4 p=0.027). Postoperative functional scores were good (WOMAC 98; HHS 79). The biomechanical hip centre was restored in all patients. 1 patient had early implant migration with subsequent stabilisation. 2 patients had radiographs concerning for failure of osteointegration. 1 patient had recurrent dislocations. CONCLUSIONS The mid-term results of the Ossis custom 3D-printed tri-flanged acetabular implant for the management of severe acetabular defects are encouraging. The improvement in functional scores and radiographic outcomes are comparable to similar designs. In addition, no cases have required revision for aseptic loosening.
Collapse
Affiliation(s)
- David C Kieser
- 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| | - Ramez Ailabouni
- 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| | - Sandra C J Kieser
- 2 Department of Radiology, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| | - Michael C Wyatt
- 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| | - Paul C Armour
- 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| | - Mark H Coates
- 2 Department of Radiology, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| | - Gary J Hooper
- 1 Department of Orthopaedic Surgery and Musculoskeletal Medicine, University of Otago, Christchurch School of Medicine, Christchurch, New Zealand
| |
Collapse
|
34
|
11-Year Mean Follow-Up of Acetabular Impaction Grafting With a Mixture of Bone Graft and Hydroxyapatite Porous Synthetic Bone Substitute. J Arthroplasty 2018; 33:1481-1486. [PMID: 29291910 DOI: 10.1016/j.arth.2017.11.065] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 11/10/2017] [Accepted: 11/29/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We report an 11-year mean follow-up of the effectiveness of bone impaction grafting with bone and hydroxyapatite (HA) for large, uncontained acetabular defects in primary and revision hip surgeries. METHODS Over 5 years, 47 total hip arthroplasties with uncontained acetabular deficiencies were performed by augmentation using an impaction graft with 50:50 mixture of freeze-dried bone allograft and HA. Ten were primary total hip arthroplasties and 37 revision procedures. X-rays were taken postoperatively, 6 weeks, 3 months, and then annually to assess incorporation of the graft, radiolucent lines, resorption, or migration of components. Functional outcomes were assessed by annual pain and function parts of the Harris Hip Score. RESULTS At a mean follow-up of 10 years, the survivorship was 100%. All patients were accounted for; 6 had died. The Harris Hip Score for pain improved from 9 and 17 (primaries and revisions, respectively) to 39 and 41. For function, there was an improvement from 20 and 19 to 32 (both groups). There were lucent lines in 8 cases, 3 cups had minor/stable migration, and one cup had significant migration (>15 mm). Graft incorporation had occurred in 20 hips. CONCLUSION This is the longest survivorship of bone impaction grafting with morcellised bone and HA substitute. Although 11-year survivorship, function and pain are excellent, radiological findings of lysis in 8 and migration in 4 cases may be of concern for the immediate future and will need close monitoring. Even in these cases, revision may be easier because of restoration of bone stock.
Collapse
|
35
|
Abstract
INTRODUCTION The treatment of extensive bone loss and massive acetabular defects can be compounded by several challenges and pitfalls. The survivorship following acetabular revision with extensive bone loss is still unsatisfactory. The goal of the present study was to analyse the outcomes of 3D-printed patient-specific acetabular components in the management of extensive acetabular defects and combined pelvic discontinuity (PD). METHODS 9 patients underwent revision THA using 3D-printed custom acetabular components to reconstruct extensive acetabular defects. The Paprosky classifications were determined in all patients. The primary outcome measure was the implant-associated failure rate. RESULTS 1 out of 9 patients suffered an implant-associated complication (11%). The overall implant-associated survival rate was 89%. The overall complication rate was 56%. CONCLUSIONS The patient-specific acetabular component technique shows promise for the treatment of patients with severe acetabular defects in revision THA. Further research aimed at reducing costs and improving the complication rate are warranted.
Collapse
|
36
|
O'Neill CJ, Creedon SB, Brennan SA, O'Mahony FJ, Lynham RS, Guerin S, Gul R, Harty JA. Acetabular Revision Using Trabecular Metal Augments for Paprosky Type 3 Defects. J Arthroplasty 2018; 33:823-828. [PMID: 29217393 DOI: 10.1016/j.arth.2017.10.031] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2017] [Revised: 10/07/2017] [Accepted: 10/15/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Trabecular Metal (TM) augments are one option when reconstructing bone loss during acetabular side revision surgery. METHODS We studied 38 consecutive patients with Paprosky type 3 defects that were revised using a TM shell and one or more augments over a 6-year period. There were 29 Paprosky type 3A defects and 9 Paprosky type 3B defects. The mean age of the patients at the time of surgery was 68.2 years (range 48-84). The mean length of follow-up was 36 months (range 18-74). RESULTS The mean preoperative short form 12 health survey improved from 27.7 before operation to 30.1 at the time of final follow-up (P = .001). The mean Western Ontario and McMaster Universities Osteoarthritis Index score improved from 53 preoperatively to a mean of 78.8 at final follow-up (P < .0001). There was evidence of radiographic loosening in 7 of the cup-augment constructs. One patient developed a deep infection requiring re-revision. Two patients required revision for aseptic loosening. CONCLUSION The use of TM in complex acetabular reconstruction is associated with good outcome in the short to medium term.
Collapse
Affiliation(s)
- Cathleen J O'Neill
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| | - Stephen B Creedon
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| | - Stephen A Brennan
- Department of Orthopaedic Surgery, Bon Secours Hospital, Cork, Ireland
| | - Fiona J O'Mahony
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| | - Rosanne S Lynham
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| | - Shane Guerin
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| | - Rehan Gul
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| | - James A Harty
- Department of Orthopaedic Surgery, South Infirmary Victoria University Hospital, Cork, Ireland
| |
Collapse
|
37
|
McLaughlin JR, Lee KR. Acetabular Revision Arthroplasty Using an Uncemented Deep Profile Jumbo Component: A Ten to Sixteen Year Follow-Up Study. J Arthroplasty 2018; 33:496-499. [PMID: 28993083 DOI: 10.1016/j.arth.2017.09.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 08/14/2017] [Accepted: 09/01/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The purpose of this study is to evaluate the outcome of revision total hip arthroplasty using an uncemented deep profile jumbo acetabular component in patients who had been followed for a minimum of 10 years postoperatively. METHODS Between 1997 and 2001, 61 revision total hip arthroplasties were performed in 58 patients, with use of the +5 Deep Profile acetabular shell. The outcome with regard to retention vs re-revision of the acetabular component was determined for every hip. At a mean of 13 years (range 10-16) postoperatively, 30 patients (32 hips) were living. The Harris hip score, radiographic results, complications, and Kaplan-Meier survivorship were evaluated. RESULTS In the entire cohort of 61 hips, 4 acetabular components have been re-revised. Two shells were re-revised for sepsis: 1 shell was re-revised for aseptic loosening and 1 for recurrent dislocation. In the 32 hips followed for a minimum of 10 years postoperatively, 2 cups have been re-revised: 1 for aseptic loosening and 1 for recurrent dislocation. One additional shell was loose by radiographic criteria. With failure defined as re-revision for any reason, implant survival (95% confidence interval) was 92.6% (81.0-97.2) at 16 years. With failure defined as re-revision for aseptic loosening, implant survival was 97.4% (82.8-99.6) at 16 years. CONCLUSION Revision total hip arthroplasty with the +5 Deep Profile acetabular component was associated with a good rate of survival at 16 years.
Collapse
Affiliation(s)
| | - Kyla R Lee
- Internal Medicine, Gundersen Healthcare, LaCrosse, Wisconsin
| |
Collapse
|
38
|
Tantalum Components in Difficult Acetabular Revisions Have Good Survival at 5 to 10 Years: Longer Term Followup of a Previous Report. Clin Orthop Relat Res 2018; 476. [PMID: 29529665 PMCID: PMC6259702 DOI: 10.1007/s11999.0000000000000005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The best method for acetabular revisions in patients with severe bone loss remains controversial; typical approaches include jumbo cups, cages, cup-cages, and custom components. Tantalum (TM) components have good results at midterm followup, but the longer term survival and complications are not available. We previously reported on a series of such reconstructions; here we provide additional followup on that group along with a larger study cohort. QUESTIONS/PURPOSES (1) What is the survival at a minimum followup of 5 years of these components implanted in difficult revisions and what is the mechanism of failure? (2) What is the most common complication of these reconstructions, and what hip scores did these patients achieve? METHODS Between 2001 and 2010, one surgeon performed 150 acetabular revisions, of which 74 (49%) were done using TM components. The general indication for use of these devices was the surgeon's perception that there was sufficient bone loss to place the reconstruction at a high risk of mechanical failure (generally Paprosky Type 3 or 4 or lower Paprosky type with < 50% host bone coverage or morbid obesity). No cages were used during this time. Fifteen patients died and 11 were lost or did not return, leaving 48 hips (46 patients) with a mean followup of 8 years (range, 5-14 years). Of these, 39 were reported on in our previous series, and nine are new in the present series; the overall group here has an additional median of 5 years followup (range, 3-7 years). Five hips had six augments placed to obtain stability. Patients were evaluated by the Harris hip score and standard radiographs; survivorship was estimated using the cumulative incidence competing risks survival analysis. The primary outcome was fixation and survival of the TM component and the secondary outcome was complications. RESULTS Cumulative incidence competing risks estimate survival free from aseptic loosening was 92% at 10 years (95% confidence interval [CI], 0.81-0.98). Dislocation, the most common complication, occurred in seven of 48 (15%) patients, and five of 48 (10%) had a reoperation for it. Survival free from any reoperation was 84% at 10 years (95% CI, 0.72-0.92). The Harris hip score improved from a mean of 50 points (SD 17) before surgery to 85 points (SD 10; p < 0.001) at latest followup. CONCLUSIONS Given the findings of this study, TM components appear to provide durable fixation at midterm followup in complex acetabular revisions. Steps to minimize dislocation, the most frequent complication of these revisions, may include the routine use of larger femoral heads. Future studies likely will need to be multisurgeon or multicenter and should evaluate different techniques and components for long-term fixation and the prevention of dislocation. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
|
39
|
Fonseca Neto CEBRD, Lima MMS, Rabello BT, Sena LDS, Zacaron Júnior LC, Viana MT. Radiographic evaluation of 19 patients with Paprosky 3A and 3B submitted to acetabular review with trabecular metal wedge. Rev Bras Ortop 2018; 53:94-100. [PMID: 29367913 PMCID: PMC5771787 DOI: 10.1016/j.rboe.2017.11.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2016] [Accepted: 01/24/2017] [Indexed: 11/26/2022] Open
Abstract
Objective This study is aimed at evaluating the fixation of trabecular metal wedges in patients who underwent revision of total hip arthroplasty with large acetabular bone defects. Methods The radiographs of 19 patients (21 hips), who underwent revision of total hip arthroplasty using trabecular metal wedges from September 2010 to December 2014 were evaluated. This study included only cases of Paprosky 3A and 3B. Preoperative and postoperative images were analyzed. Non-fixation of the implant was defined by the presence of angular variation of the component higher 10 degrees or displacement greater than 6 mm. Patients with follow-up times of less than 24 months or who did not attend the last two appointments were excluded from the study. Results The mean follow-up time was 39.4 months (25–61). Fixation was achieved in all cases despite its complexity. There was only one case of dislocation that was treated with open reduction. One case developed infection, and was surgically approached on two occasions, with extensive debridement and intravenous antibiotics following protocol, with good evolution. Conclusion The implanted trabecular metal wedges showed excellent results in the short- and medium-term and may represent another option in the reconstruction of large acetabular defects, sometimes replacing bone reconstruction that uses bone tissue banks or autologous graft.
Collapse
|
40
|
Avaliação radiográfica de 19 pacientes Paprosky 3 A e 3 B submetidos à revisão acetabular com cunha de metal trabeculado. Rev Bras Ortop 2018. [DOI: 10.1016/j.rbo.2017.01.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
|
41
|
Use of a revision cup for treatment of Zurich cementless acetabular cup loosening. Vet Comp Orthop Traumatol 2017; 26:408-15. [DOI: 10.3415/vcot-13-02-0029] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2013] [Accepted: 05/22/2013] [Indexed: 11/17/2022]
Abstract
SummaryLoosening of the acetabular cup is one of the most common complications following total hip replacement and has an incidence rate of 1.8% to 36.8%. The objective of this study was to describe the surgical technique for the application of a cementless acetabular component specifically designed for treatment of cup loosening and preliminary clinical experience. The Kyon revision cup is composed of two components; the first is a perforated titanium outer shell with holes for 2.4 mm titanium screws, which is impacted into the acetabulum after removal of the loose cup and reaming of the acetabulum. It is secured with a variable number of screws. The second component is an inner plain titanium cup with an ultra-high-molecular-weight polyethylene insert, which is impacted into the outer shell to obtain press-fit stability. This revision cup was used in 31 dogs with cup loosening and a minimum follow-up period of six months. There were four intra-operative complications and two postoperative complications. The main intra-operative complication was difficulty inserting the inner cup into the outer shell. Postoperative complications included craniodorsal hip luxation in one dog, which was successfully managed, and cup loosening in another dog, which required explantation of the prosthesis. The main advantage of the revision cup appears to be increased implant stability afforded by screw fixation. Our initial clinical results in 31 dogs were promising; all but one dog had a successful clinical outcome.
Collapse
|
42
|
Yoshino K, Tsukeoka T, Tsuneizumi Y, Lee TH, Nakamura J, Suzuki M, Ohtori S. Revision Total Hip Arthroplasty Using a Cementless Cup Supporter and Iliac Autograft: A Minimum of 15-Year Follow-Up. J Arthroplasty 2017; 32:3495-3501. [PMID: 28697865 DOI: 10.1016/j.arth.2017.06.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 05/31/2017] [Accepted: 06/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Bone deficiency in revision total hip arthroplasty is a surgical challenge. The Murata-Chiba cup supporter (MC support ring) is an acetabular component supporter for a cementless porous-coated cup. The purpose of this study is to examine the clinical and radiographic outcomes of reconstruction of acetabular bone deficiency using iliac autografts supported by an MC support ring in a revision setting with minimum 15-year follow-up. METHODS Fifty-nine consecutive revision total hip arthroplasties (57 patients) using the MC support ring were followed for a minimum of 15 years. Nine hips had American Academy of Orthopaedic Surgeons type II deficiency and 24 had type III defects of the acetabulum. Clinical outcomes were evaluated using the Harris hip score. Radiographic evaluation included assessment for loosening and bone graft incorporation. Kaplan-Meier survival analysis was performed. RESULTS At a minimum 15-year follow-up (mean, 17.6 years), 32 patients (33 hips) were alive, 17 patients (18 hips) were deceased, and 8 patients (8 hips) were lost to follow-up. The mean Harris hip score improved from 44.3 to 77.2 at final follow-up. Four hips required reoperation due to deep infection (2 hips) and liner dissociation (2 hips), but no acetabular components were revised for aseptic loosening. Incorporation of the bone graft occurred in all cases. One unrevised patient had radiographic failure. Survivorship at 15 years with re-revision or radiographic failure as the end point was 90.6% (95% confidence interval, 83.0%-98.8%). CONCLUSION The reconstruction of acetabular bone deficiency using autografts supported by an MC support ring provided satisfactory clinical and radiological results at 17.6 years postoperatively.
Collapse
Affiliation(s)
- Kensuke Yoshino
- Department of Orthopaedic Surgery, Chiba Rehabilitation Center, Chiba, Japan; Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Tadashi Tsukeoka
- Department of Orthopaedic Surgery, Chiba Rehabilitation Center, Chiba, Japan
| | | | - Tae Hyun Lee
- Department of Orthopaedic Surgery, Chiba Rehabilitation Center, Chiba, Japan
| | - Junichi Nakamura
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
| | - Masahiko Suzuki
- Center for Frontier Medical Engineering, Chiba University, Chiba, Japan
| | - Seiji Ohtori
- Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan
| |
Collapse
|
43
|
Prieto HA, Kralovec ME, Berry DJ, Trousdale RT, Sierra RJ, Cabanela ME. Structural Allograft Supporting a Trabecular Metal Cup Provides Durable Results in Complex Revision Arthroplasty. J Arthroplasty 2017; 32:3488-3494. [PMID: 28662954 DOI: 10.1016/j.arth.2017.05.051] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Revised: 05/17/2017] [Accepted: 05/30/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Revision total hip arthroplasty (THA) is challenging specially in the presence of severe acetabular bone deficiency. We report the use of a highly porous revision shell augmented by structural allograft to provide structural support and coverage to the acetabular component. METHODS We identified 56 patients (58 hips) undergoing revision THA, where a trabecular metal revision cup was supported by structural allograft. Mean follow-up was 5.4 years (range 2-12 years). Preoperatively acetabular bone defects were classified as Paprosky 2A in 6 hips (10%), 2B in 12 hips (21%), 2C in 12 hips (21%), 3A in 11 hips (19%), and 3B in 17 hips (29%). Structural allograft configuration was classified as type 1 (flying buttress) in 13 hips, type 2 (dome support) in 23 hips, and type 3 (footings) in 17 hips, with 5 hips having combined configurations. RESULTS All hips showed evidence of union between the allograft and host bone at latest follow-up, 14 hips had partial resorption of the allograft that did not affect cup stability. Three acetabular components demonstrated failure of ingrowth. Survivorship-free from radiographic acetabular loosening as end point was 94% at 5 years. The 5-year survivorship with revision for any reason as end point was 90%. CONCLUSION Trabecular metal shells combined with structural bone allograft in revision THA demonstrate excellent midterm survival, with 94% of acetabular components obtaining stable union onto host bone at 5 years. Allograft restored bone stock with minimal resorption, and when it occurred did not alter the survivorship of the acetabular component.
Collapse
Affiliation(s)
- Hernan A Prieto
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Daniel J Berry
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | | - Rafael J Sierra
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | | |
Collapse
|
44
|
Hoberg M, Holzapfel BM, Steinert AF, Kratzer F, Walcher M, Rudert M. [Treatment of acetabular bone defects in revision hip arthroplasty using the Revisio-System]. DER ORTHOPADE 2017; 46:126-132. [PMID: 28012061 DOI: 10.1007/s00132-016-3375-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND Many different systems for the management of primary and secondary acetabular defects are available, each with its inherent advantages and disadvantages. The Revisio-System is a press-fit oval mono-block implant that makes a defect-oriented reconstruction and restoration of the center of rotation possible. MATERIAL AND METHODS In this study, we retrospectively reviewed the outcome of 92 consecutive patients treated with this oval press-fit cup due to periacetabular bone loss. The average follow-up was 58.2 months. Defects were classified according to D'Antonio. There were 39 type II, 38 Type III, and 15 type IV defects. After an average of 4.9 years, the implant survival rate was 94.6% with cup revision as the end point and 89.1% with revision for any reason as the end point. The Harris Hip Score increased from 41.1 preoperatively to 62.3 postoperatively. The mean level of pain measured with the Visual Analogue Scale (VSA) was reduced from 6.9 preoperatively to 3.8 postoperatively. RESULTS The Revisio-System represents a promising toolbox for defect-orientated reconstruction of acetabular bone loss in revision hip arthroplasty. Our results demonstrate that the implantation of the Revisio-System can result in a good mid-term clinical outcome.
Collapse
Affiliation(s)
- M Hoberg
- Orthopädische Klinik König-Ludwig Haus, Lehrstuhl der Julius-Maximilians Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Deutschland.
| | - B M Holzapfel
- Orthopädische Klinik König-Ludwig Haus, Lehrstuhl der Julius-Maximilians Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Deutschland.,Regenerative Medicine, Institute of Health and Biomedical Innovation, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, QLD 4049, Brisbane, Australien
| | - A F Steinert
- Orthopädische Klinik König-Ludwig Haus, Lehrstuhl der Julius-Maximilians Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Deutschland
| | - F Kratzer
- Endogap Klinik für Gelenkersatz, Klinikum Garmisch-Partenkirchen, Auenstr. 6, 82467, Garmisch-Partenkirchen, Deutschland
| | - M Walcher
- Orthopädische Klinik König-Ludwig Haus, Lehrstuhl der Julius-Maximilians Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Deutschland
| | - M Rudert
- Orthopädische Klinik König-Ludwig Haus, Lehrstuhl der Julius-Maximilians Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Deutschland
| |
Collapse
|
45
|
Dwivedi C, Gokhale S, Khim HG, Oh JK, Shon WY. Acetabular Defect Reconstruction with Trabecular Metal Augments: Study with Minimum One-year Follow-up. Hip Pelvis 2017; 29:168-175. [PMID: 28955682 PMCID: PMC5612976 DOI: 10.5371/hp.2017.29.3.168] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2017] [Revised: 06/20/2017] [Accepted: 07/06/2017] [Indexed: 01/15/2023] Open
Abstract
Purpose High rates of mechanical failure have been reported in type III acetabular defects. Recently porous trabecular metal augments have been introduced with, excellent biomechanical characteristics and biocompatibility, allowing early stability and greater bone ingrowth. The aim of the study was to assess the short term clinical and radiological outcome of the trabecular metal augments. Materials and Methods We performed, 22 revision total hip arthroplasties (THA) and 6 primary THA (total 28) using trabecular metal augments to reconstruct acetabular defect between 2011 to 2015. Among 28 patients, 18 were males, 10 females. Mean age of patients was 61.21 years. Paprosky classification for acetabular bone defects was used. Eighteen cases were classified as grade 3 A and 10 cases as grade 3B. Hip center was calculated in each case preoperatively and compared postoperatively to check whether it has been brought down. Clinical outcome assessed using Harris hip score (HHS) and radiological outcomes as osteolysis in acetabular zones and osseointegration, according to Moore's criteria. Results HHS improved from 58.00 to 86.20. Centre of rotation of hip joint corrected from 38.90 mm preoperatively to 23.85 mm postoperatively above the interteardrop line. Among 28 patients, 18 patients had three or more signs of osseointegration (Moore's criteria), during final follow up and 10 had one/two signs. No radiolucency, osteolysis, or loosening found during follow up radiographic examination. Conclusion Our study showed that trabecular metal augments were highly satisfactory in short term. However, long term study is required for better evaluation.
Collapse
Affiliation(s)
- Chirayu Dwivedi
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Korea
| | - Sandeep Gokhale
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Korea
| | - Hyun Gon Khim
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Korea
| | - Jeon Keon Oh
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Korea
| | - Won Yong Shon
- Department of Orthopaedic Surgery, Korea University Guro Hospital, Seoul, Korea
| |
Collapse
|
46
|
Abstract
Pelvic discontinuity is a challenging complication encountered during revision total hip arthroplasty. Pelvic discontinuity is defined as a separation of the ilium superiorly from the ischiopubic segment inferiorly and is typically a chronic condition in failed total hip arthroplasties in the setting of bone loss. After a history and a physical examination have been completed and infection has been ruled out, appropriate imaging must be obtained, including plain hip radiographs, oblique Judet radiographs, and often a CT scan. The main management options are a hemispheric acetabular component with posterior column plating, a cup-cage construct, pelvic distraction, and a custom triflange construct. The techniques have unique pros and cons, but the goals are to obtain stable and durable acetabular component fixation and a healed or unitized pelvis while minimizing complications.
Collapse
|
47
|
Jo WL, Lim YW, Im JH, Kim SC, Kwon SY, Kim YS. Comparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty. Hip Pelvis 2017; 29:24-29. [PMID: 28316959 PMCID: PMC5352722 DOI: 10.5371/hp.2017.29.1.24] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 12/13/2016] [Accepted: 12/20/2016] [Indexed: 12/28/2022] Open
Abstract
Purpose It is challenging procedure to revise acetabular component in acetabulum with severe bone defect or deformity. The jumbo cup is good option for revisional arthroplasty in large bone defect. The purpose of this study is to compare the prognosis of revisional total hip arthroplasty using jumbo cup with peripheral rim fixation and no rim fixation. Materials and Methods We included the patients who had performed acetabular revisional total hip arthroplasty from January 2002 to March 2015 in our institute. Total of 51 hips (51 patients) were included. The mean follow up period was 51 months (range, 12 to 154 months) and mean age was 60.7 years (range, 30 to 81 years). We divided into two groups (peripheral rim fixation group and no rim fixation group) by anteroposterior and lateral plain radiograph. We compared survival rate, hip center change and clinical outcomes between two groups. Results There were 37 patients in peripheral rim fixation group and 14 patients in no rim fixation group. There was one patient who had aseptic loosening necessary to re-revision in rim fixation group and 3 patients in no rim fixation group. And one patient had superficial infection in rim fixation group and one patient had periprosthetic fracture in no rim fixation group. Survival rate was higher in the peripheral rim fixation group (97.3%) than no rim fixation group (78.6%, P=0.028) Conclusion Based on our findings, peripheral rim fixation might be recommended to improve short-term outcome after revision total hip arthroplasty using jumbo cup.
Collapse
Affiliation(s)
- Woo-Lam Jo
- Department of Orthopaedic Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| | - Young-Wook Lim
- Department of Orthopaedic Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| | - Jin-Hyung Im
- Department of Orthopaedic Surgery, Gyeongsang National University Changwon Hospital, Changwon, Korea
| | - Seung-Chan Kim
- Department of Orthopaedic Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| | - Soon-Yong Kwon
- Department of Orthopaedic Surgery, The Catholic University of Korea, Yeoeuido St. Mary's Hospital, Seoul, Korea
| | - Yong-Sik Kim
- Department of Orthopaedic Surgery, The Catholic University of Korea, Seoul St. Mary's Hospital, Seoul, Korea
| |
Collapse
|
48
|
Cadossi M, Garcia FL, Sambri A, Andreoli I, Dallari D, Pignatti G. A 2- to 7-Year Follow-Up of a Modular Iliac Screw Cup in Major Acetabular Defects: Clinical, Radiographic and Survivorship Analysis With Comparison to the Literature. J Arthroplasty 2017; 32:207-213. [PMID: 27449716 DOI: 10.1016/j.arth.2016.06.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 05/10/2016] [Accepted: 06/11/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Inadequate acetabular bone stock is a major issue in total hip arthroplasty, and several treatment options are available. Stemmed cups have been used in this scenario with variable results. A novel modular polyaxial uncemented iliac screw cup (HERM-BS-Sansone cup-Citieffe s.r.l., Calderara di Reno, Bologna, Italy) has been recently introduced to overcome the drawbacks of stemmed cups. In this retrospective study, we report the results of this cup in patients with large acetabular bone defects at 2- to 7-year follow-up. METHODS We evaluated a consecutive series of 121 hips (118 revisions and 3 complex primary arthroplasties) treated with this novel cup at a mean follow-up of 46 months. Kaplan-Meier survival analysis was performed with implant revision for any reason as a primary end point. Further survival analysis was performed excluding septic failures. Clinical outcome was assessed with the Harris Hip Score. RESULTS There had been 7 reoperations: 1 for aseptic loosening, 5 for deep infection, and 1 for recurrent dislocation. In 5 cases, the cup was removed; estimated survival rate at 5-year follow-up with implant removal for any reason was 95.6% (95% confidence interval = 91-99), and 98.3% (95% CI = 96-100) excluding those failed for infection. Mean Harris Hip Score at latest follow-up was 77 points (range, 44-95; standard deviation = 11.9). CONCLUSION The present findings show the short-term efficacy of the iliac screw cup with respect to implant survival. A longer follow-up and a larger number of patients are necessary to confirm the encouraging preliminary results.
Collapse
Affiliation(s)
| | - Flávio Luís Garcia
- Ribeirão Preto Medical School (University of São Paulo), Ribeirão Preto, São Paulo, Brazil
| | | | | | | | | |
Collapse
|
49
|
Colo E, Rijnen WHC, Gardeniers JWM, van Kampen A, Schreurs BW. Satisfying Results of Primary Hip Arthroplasty in Patients With Hip Dysplasia at a Mean Followup of 20 Years. Clin Orthop Relat Res 2016; 474:2462-2468. [PMID: 27492686 PMCID: PMC5052201 DOI: 10.1007/s11999-016-4998-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Accepted: 07/18/2016] [Indexed: 01/31/2023]
Abstract
BACKGROUND Developmental dysplasia of the hip (DDH) is a common cause of secondary osteoarthritis (OA) in younger patients, and when end-stage OA develops, a THA can provide a solution. Different options have been developed to reconstruct these defects, one of which is impaction bone grafting combined with a cemented cup. To determine the true value of a specific technique, it is important to evaluate patients at a long-term followup. As there are no long-term studies, to our knowledge, on THA in patients with DDH using impaction bone grafting with a cemented cup, we present the results of this technique at a mean of 15 years in patients with previous DDH. QUESTIONS/PURPOSES We wished to determine (1) the long-term probability of cup revision at a minimum followup of 15 years for cemented acetabular impaction bone grafting in patients with DDH; (2) the radiographic appearance of the bone graft and radiographic signs of implant loosening; and (3) the complications and pre- and postoperative Harris hip scores with cemented THA combined with impaction bone grafting in patients with previous DDH. METHODS Between January 1984 and December 1995 we performed 28 acetabular impaction bone grafting procedures for secondary OA believed to be caused by DDH in 22 patients; four patients died before 15 years, leaving 24 hips in 18 patients for retrospective analysis at a minimum of 15 years (mean, 20 years; range, 16-29 years). The diagnosis of DDH was made according to preoperative radiographs and intraoperative findings. All grades of dysplasia were included; five patients had Crowe Group I, eight had Group II, nine had Group III, and two had Group IV DDH. No patients were lost to followup. In all cases the acetabular defects were combined cavitary and segmental. Owing to the high number of deaths, we performed a competing-risk analysis to determine the probability of cup revision surgery. RESULTS The competing-risk analysis showed cumulative incidences at 15 and 20 years, with endpoint revision for any reason of 7% (95% CI, 0%-17%), whereas this was 4% (95% CI, 0%-11%) with endpoint revision of the cup for aseptic loosening. Three revision surgeries were performed. Two cup revisions were performed for aseptic loosening at 12 and 26 years. Another cup revision was performed owing to sciatic nerve problems at 2 years. A stable radiographic appearance of the graft was seen in 19 of the 25 unrevised hips. Four hips showed acetabular radiolucent lines and two showed acetabular osteolysis. None of the unrevised cups showed migration or radiographic failure. Postoperative complications included a pulmonary embolus and a superficial wound infection. The Harris hip score improved from 37 (range, 9-72) preoperatively to 83 (range, 42-99) at latest followup. CONCLUSIONS Cemented primary THA with the use of impaction bone grafting shows satisfying long-term results in patients with previous DDH. For future research it is important to evaluate this technique in a larger cohort with a long-term followup. Other techniques also should be evaluated at long-term followup to be able to compare different techniques in this important and specific patient group. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
Affiliation(s)
- Ena Colo
- Department of Orthopaedic Surgery, Radboud University Medical Center, Nijmegen, Netherlands
| | - Wim H. C. Rijnen
- Department of Orthopaedic Surgery, Radboud University Medical Center, Nijmegen, Netherlands
| | - Jean W. M. Gardeniers
- Department of Orthopaedic Surgery, Radboud University Medical Center, Nijmegen, Netherlands
| | - Albert van Kampen
- Department of Orthopaedic Surgery, Radboud University Medical Center, Nijmegen, Netherlands
| | - B. Willem Schreurs
- Department of Orthopaedic Surgery, Radboud University Medical Center, Nijmegen, Netherlands ,Department of Orthopaedic Surgery 611, Radboud University Medical Center, PO Box 9101, 6500 HB Nijmegen, Netherlands
| |
Collapse
|
50
|
Use of porous tantalum components in Paprosky two and three acetabular revision. A minimum five-year follow-up of fifty one hips. INTERNATIONAL ORTHOPAEDICS 2016; 41:911-916. [PMID: 27766385 DOI: 10.1007/s00264-016-3312-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Accepted: 10/03/2016] [Indexed: 02/08/2023]
Abstract
INTRODUCTION Recent studies have reported short-term favourable results of tantalum-made components in acetabular revisions with bone loss. However, there is a lack of information regarding the mid to long-term results of such components. OBJECTIVES The objective of this study was to analyse the outcome and survivorship of acetabular revision hip arthroplasty using tantalum components for loosening associated with bone loss at a minimum of five-year follow-up. METHODS We retrospectively reviewed 51 consecutive patients (51 hips) who had an acetabular revision using porous tantalum components at a minimum follow-up of five years. The mean age was 64 years (range, 31-87). There were 27 males and 24 females, 47 right hips and four left hips. Twenty-five (49 %) included a femoral revision. According to Paprosky's classification 18 hips were classified type 2A, 11 type 2B, ten type 2C, seven type 3A and five type 3B. No bone grafting was performed. Sixteen hips (31.3 %) required the use of additional tantalum-made augments stabilized by screws and cement at the cup-augment interface. RESULTS At a mean followup of 6.8 years (range, 5.1-10 years), the Harris hip score improved from 44 pre- operatively (range, 23-72) to 84 post-operatively (range, 33-98). The mean post-operative hip centre position in relation to the teardrop was 29 mm (range, 20-43 mm) horizontally and 21 mm (range, 8-36 mm) vertically. The mean acetabular inclination was 42° (range, 17-60°). Six hips (11.7 %) required a re-operation without component revision (two for chronic instability, one ossification removal, one haematoma, one deep infection and one periprosthetic femoral fracture). One patient required a cup re-revision for septic loosening. No aseptic loosening occurred. At last followup the radiological analysis showed one evolutive osteolysis and one screw breakage. The global survivorship was 92.3 % at 64 months. If only aseptic loosening was defined as the end-point the survivorship was 100 % at 64 months. CONCLUSIONS When facing an acetabular revision with severe bone loss, tantalum-made components can provide a stable fixation. This study at a minimum five-year follow-up compares favourably with other reconstruction techniques, but longer follow-up is still required.
Collapse
|