1
|
Mori R, Matsuo M, Saimoto K, Nagamatsu Y, Washio A, Ono K, Kitamura C, Ikeda H. 3D-printable bioactive glass-based polymer-infiltrated ceramic for biomimetic tooth root applications. J Mech Behav Biomed Mater 2025; 169:107060. [PMID: 40412351 DOI: 10.1016/j.jmbbm.2025.107060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2025] [Revised: 05/09/2025] [Accepted: 05/13/2025] [Indexed: 05/27/2025]
Abstract
Titanium implants are widely utilized for tooth root reconstruction due to their excellent mechanical and biological properties. However, their mechanical properties differ from those of dentin. This study aims to develop a 3D-printable polymer-infiltrated ceramic network (PICN) as a tooth root restoration material that mimics the natural root shape, mechanical properties, and biocompatibility. A bioactive glass (BG)-based photocurable slurry was prepared for vat photopolymerization, printed, sintered, and subsequently polymer-infiltrated to form 3D-printable PICN (3D-PICN). For comparison, 3D-printable BG (3D-BG), a dense ceramic without resin infiltration, was fabricated using the same printing and sintering process. The photocurable slurry was characterized for its rheological and photopolymerization behaviors, including viscosity, cure depth, degree of conversion, overgrowth, and printing accuracy. The results confirmed its suitability for vat photopolymerization, enabling the precise fabrication of tooth root-shaped structures. Mechanical properties, including work of fracture, flexural strength, flexural modulus, and Vickers hardness, were evaluated for both 3D-PICN and 3D-BG. The results revealed that the mechanical properties of 3D-PICN closely match those of dentin, whereas 3D-BG exhibits properties similar to enamel. Biocompatibility was assessed through in vitro simulated body fluid immersion tests and in vivo implantation in a ten-week-old rat tibia model, followed by histological analysis. The findings confirmed good biocompatibility of 3D-PICN with bone tissue. The 3D-PICN demonstrated excellent printability, mechanical compatibility with dentin, and favorable biocompatibility, suggesting its potential as a promising material for tooth root reconstruction applications.
Collapse
Affiliation(s)
- Ryo Mori
- Division of Biomaterials, Kyushu Dental University, Fukuoka, 803-8580, Japan; Division of Endodontics and Restorative Dentistry, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Misaki Matsuo
- Division of Biomaterials, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Kanna Saimoto
- Division of Biomaterials, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Yuki Nagamatsu
- Division of Biomaterials, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Ayako Washio
- Division of Endodontics and Restorative Dentistry, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Kentaro Ono
- Division of Physiology, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Chiaki Kitamura
- Division of Endodontics and Restorative Dentistry, Kyushu Dental University, Fukuoka, 803-8580, Japan
| | - Hiroshi Ikeda
- Division of Biomaterials, Kyushu Dental University, Fukuoka, 803-8580, Japan.
| |
Collapse
|
2
|
Liang X, Yu B, Dai Y, Wang Y, Hu M, Zhong HJ, He J. Three-Dimensional Printing Resin-Based Dental Provisional Crowns and Bridges: Recent Progress in Properties, Applications, and Perspectives. MATERIALS (BASEL, SWITZERLAND) 2025; 18:2202. [PMID: 40428939 PMCID: PMC12113103 DOI: 10.3390/ma18102202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2025] [Revised: 05/05/2025] [Accepted: 05/08/2025] [Indexed: 05/29/2025]
Abstract
Three-dimensional (3D) printing represents a pivotal technological advancement in dental prosthetics, fundamentally transforming the fabrication of provisional crowns and bridges through innovative vat photopolymerization methodologies, specifically stereolithography (SLA) and digital light processing (DLP). This comprehensive scholarly review critically examines the technological landscape of 3D-printed resin-based dental provisional crowns and bridges, systematically analyzing their material performance, clinical applications, and prospective developmental trajectories. Empirical investigations demonstrate that these advanced restorations exhibit remarkable mechanical characteristics, including flexural strength ranging from 60 to 90 MPa and fracture resistance of 1000-1200 N, consistently matching or surpassing traditional manufacturing techniques. The digital workflow introduces substantial procedural innovations, dramatically reducing fabrication time while simultaneously achieving superior marginal adaptation and internal architectural precision. Despite these significant technological advancements, critical challenges persist, encompassing material durability limitations, interlayer bonding strength inconsistencies, and the current paucity of longitudinal clinical evidence. Contemporary research initiatives are strategically focused on optimizing resin formulations through strategic filler incorporation, enhancing post-processing protocols, and addressing fundamental limitations in color stability and water sorption characteristics. Ultimately, this scholarly review aims to provide comprehensive insights that will inform evidence-based clinical practices and delineate future research trajectories in the dynamically evolving domain of digital dentistry, with the paramount objective of advancing patient outcomes through technological innovation and precision-driven methodological approaches.
Collapse
Affiliation(s)
- Xiaoxu Liang
- School of Arts and Sciences, Guangzhou Maritime University, Guangzhou 510725, China;
| | - Biao Yu
- School of Chemistry and Chemical Engineering, Lingnan Normal University, Zhanjiang 524048, China;
| | - Yuan Dai
- School of Health Preservation and Rehabilitation, Chengdu University of Traditional Chinese Medicine, Chengdu 611137, China;
| | - Yueyang Wang
- Joint Key Laboratory of the Ministry of Education, Institute of Applied Physics and Materials Engineering, University of Macau, Avenida da Universidade, Taipa, Macau SAR, China;
| | - Mingye Hu
- State Key Laboratory of Bioactive Molecules and Druggability Assessment, Jinan University, Guangzhou 510632, China;
| | - Hai-Jing Zhong
- State Key Laboratory of Bioactive Molecules and Druggability Assessment, Jinan University, Guangzhou 510632, China;
| | - Jingwei He
- School of Materials Science and Engineering, South China University of Technology, Guangzhou 510641, China
| |
Collapse
|
3
|
Jo YH, Cho JH, Jee EB, Yoon HI. Physical properties, microbial adhesion, and biocompatibility of additively manufactured ceramic-reinforced resin: Effect of zwitterionic polymer content. J Prosthet Dent 2025; 133:1344.e1-1344.e9. [PMID: 39984406 DOI: 10.1016/j.prosdent.2025.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Revised: 02/03/2025] [Accepted: 02/05/2025] [Indexed: 02/23/2025]
Abstract
STATEMENT OF PROBLEM Studies focusing on the effect of zwitterionic polymer content on the physical and biological properties of additively manufactured (AM) ceramic-reinforced resin for dental applications are lacking. PURPOSE The purpose of this in vitro study was to evaluate the effect of different concentrations of 2-methacryloyloxyethyl phosphorylcholine (MPC) on the surface properties, mechanical properties, microbial adhesion, and cellular responses of ceramic-reinforced resins. MATERIAL AND METHODS Four different groups of AM resins filled with 60 wt% silicate-based composites and varying concentrations of MPC were prepared: 0 wt% (CRN), 1.1 wt% (CRM1), 2.2 wt% (CRM2), and 3.3 wt% (CRM3). Test specimens were fabricated from the resins using digital light processing and were tested for surface roughness (Sa and Ra), flexural strength and modulus, Vickers hardness (HV), and contact angle. The adhesion of oral microbes (Streptococcus mutans and Streptococcus gordonii), cytotoxicity, and cell viability of tested resins were also assessed. One-way analyses of variances and post hoc analyses using the Bonferroni correction and Tukey HSD tests were conducted to detect statistical differences among the groups (α=.05). RESULTS CRM2 exhibited significantly lower Ra (P=.020) and Sa (P=.013) values than CRM3, as well as greater flexural strength (P=.002) and modulus (P=.049), HV (P<.001), and contact angle (P=.015). CRM3 showed significantly lower flexural strength and modulus, HV, and contact angle than CRN (all P<.001). Both CRM2 and CRM3 exhibited significantly reduced adhesion of S. gordonii and S. mutans compared with CRN (all P<.001). Regardless of MPC content, the tested resins demonstrated biocompatibility and showed no signs of cytotoxicity. CONCLUSIONS Incorporating low-concentration MPC into AM ceramic-reinforced resins significantly changed the surface properties, mechanical properties, microbial adhesion, and biocompatibility. CRM2 provided an optimal balance between structural integrity and bacterial-repellent activity while maintaining biocompatibility.
Collapse
Affiliation(s)
- Ye-Hyeon Jo
- Senior Researcher, Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Jun-Ho Cho
- Assistant Professor, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Eun-Byeol Jee
- Researcher, Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Hyung-In Yoon
- Associate Professor, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea; and Visiting Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
4
|
Diken Türksayar AA, Schulnig S, Spintzyk S, Yeşil Kurt İB. Investigating the influence of infill pattern and layer height on the mechanical and bonding behavior of additively manufactured PEEK for dental applications. J Prosthet Dent 2025:S0022-3913(25)00246-X. [PMID: 40169346 DOI: 10.1016/j.prosdent.2025.03.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2024] [Revised: 03/05/2025] [Accepted: 03/07/2025] [Indexed: 04/03/2025]
Abstract
STATEMENT OF PROBLEM Current knowledge regarding the influence of infill pattern and layer height on the flexural and shear bond strength of polyetheretherketone (PEEK) manufactured via fused filament fabrication technology remains limited. PURPOSE The purpose of this in vitro study was to investigate the impact of infill pattern and layer height on the shear bond strength (SBS) and the flexural strength (FS) of additively manufactured PEEK bars and disks relevant to dental applications. MATERIAL AND METHODS The PEEK specimens were prepared in 9 groups (n=10), whereby different layer heights (0.1, 0.2, and 0.3 mm) and different infill patterns (±30, ±45 lines, concentric) were used. The surface roughness (Ra) was recorded with a confocal microscope. For the SBS test, resin composites were applied on the disk surface. All the specimens were subjected to thermal aging. The SBS and FS test was performed through a universal testing device. Two-way ANOVA, 1-way ANOVA, post hoc Tukey, and Tamhane tests were used for statistical analysis. (α=.05) RESULTS: The highest SBS values were observed at a layer height of 0.1 mm. The infill pattern had a significant effect on FS at all layer heights (0.1 mm P=.016, 0.2 mm P=.010, 0.3 mm P=.010). While the highest FS values at a 0.1-mm layer height were observed in the concentric pattern, no significant difference was identified between the L45 and L30 groups (P=.186). CONCLUSIONS Lower layer heights strongly influenced the Ra, SBS and FS, with the highest SBS achieved with a layer height of 0.1 mm. To improve the mechanical properties of PEEK, the process parameters for additive manufacturing should be optimized.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Associate Professor and Department Head, Department of Prosthodontics, Biruni University, Faculty of Dentistry, İstanbul, Turkey; and Guest Researcher, ADMiRE Research Center, Carinthia University of Applied Sciences, Villach, Austria
| | - Sandra Schulnig
- Senior Researcher, ADMiRE Research Center, Carinthia University of Applied Sciences, Villach, Austria
| | - Sebastian Spintzyk
- Associate Professor, ADMiRE Research Center, Carinthia University of Applied Sciences, Villach, Austria.
| | - İrem Beril Yeşil Kurt
- Doctoral student, Department of Prosthodontics, Biruni University, Faculty of Dentistry, İstanbul, Turkey
| |
Collapse
|
5
|
Alammar A, Att W, Beuer F. The Accuracy of 3D-Printed Fixed Dental Restorations. J ESTHET RESTOR DENT 2025; 37:1047-1061. [PMID: 39648648 PMCID: PMC12080092 DOI: 10.1111/jerd.13365] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2024] [Revised: 10/28/2024] [Accepted: 10/30/2024] [Indexed: 12/10/2024]
Abstract
OBJECTIVE The aim of this in vitro study was to evaluate the accuracy of resin-based fixed dental restorations, namely veneers, single crowns, and four-unit fixed partial dental prosthesis (FPDs), using two different 3D printing technologies and polymer-based materials. MATERIALS AND METHODS A standard maxillary polyurethane jaw model containing prepared teeth was scanned using an intraoral scanner. The generated STL data were used to design the restorations virtually using CAD software. Two 3D printers were utilized for the provisional digital light processing and stereolithography for the castable resin patterns. Each printer produced 10 specimens of each type of restoration, for a total of 80 restorations. The 3D-printed restorations were then 3D scanned using the same intraoral scanner and evaluated for external and internal dimensional accuracy in terms of trueness and precision. A one-way ANOVA and two-sample T-test were implemented to compute the precision (variability between groups) and trueness (with the designed CAD model). A level of statistical significance of p-value < 0.05 was set. RESULTS Statistical differences in the external dimensional analysis of the incisors, molars, and four-unit FPD with p-values < 0.001, 0.002, and 0.004, respectively. For the internal dimensional analysis, the overall mean values of trueness ranged between 17 and 52 μm, and the variability was significant. CONCLUSION The external and internal dimensional accuracy values of the 3D-printed fixed dental restorations in this in vitro study in terms of trueness can be clinically accepted after chairside modifications. However, significant variability between the 3D-printed restorations was observed. Further investigations are needed to improve the accuracy of the 3D-printed fixed dental restorations. CLINICAL SIGNIFICANCE In terms of clinical applications, 3D-printed fixed dental restorations produced by both 3D-printing technologies and polymer-based materials achieved acceptable levels of trueness, although some variability was observed. Significant deviations from the CAD model may require further chairside adjustments. Future integration of AI with 3D-printing may further improve the accuracy and efficiency of fixed dental restoration production.
Collapse
Affiliation(s)
- Amirah Alammar
- Department of ProsthodonticsUniversity Hospital Berlin CharitéBerlinGermany
| | - Wael Att
- Founder and DirectorThe Face Dental GroupBostonMassachusettsUSA
| | - Florian Beuer
- Department of ProsthodonticsUniversity Hospital Berlin CharitéBerlinGermany
| |
Collapse
|
6
|
Németh A, Vitai V, Kelemen K, Teutsch B, Szabó B, Gerber G, Varga G, Fazekas R, Hegyi P, Borbély J. Comparison of fit and trueness of single-unit and short-span fixed dental restorations fabricated by additive and subtractive manufacturing-A systematic review and meta-analysis. J Dent 2025; 153:105527. [PMID: 39706323 DOI: 10.1016/j.jdent.2024.105527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 11/28/2024] [Accepted: 12/09/2024] [Indexed: 12/23/2024] Open
Abstract
OBJECTIVES Numerous studies have been conducted on the adaptation of dental restorations fabricated by additive (AM) and subtractive manufacturing (SM); however, the results are conflicting. This systematic review and meta-analysis aimed to evaluate the fit and trueness of fixed restorations made by AM compared to SM. DATA Studies investigating internal fit, marginal fit, and trueness of fixed prostheses were involved. SOURCES The protocol was registered in PROSPERO (registration number CRD42022323090). An electronic search was performed with a predefined search query across four medical databases on the 6th of September 2023. STUDY SELECTION A total of 57 eligible studies were included and sub-grouped by material type (metals, ceramics, acrylic resins, composites). The outcomes were specified as internal fit, marginal fit, and trueness expressed in micrometer (µm). Further subgrouping was based on measurement area: axial, occlusal, and marginal. When we analyzed marginal fit, there were no statistically significant differences between the two techniques in any of the subgroups. The measurement of internal fit metal and ceramic restorations provided no significant differences. However, milled acrylic resin restorations showed a significantly higher occlusal gap compared to 3D printed prostheses with 39.12 µm (95 % CI: 12.44; 65.79). In the case of trueness, a statistically significant difference was observed between ceramic AM and SM restorations with -47.76 µm (95 % CI: -95.51; -0.00). QUIN and GRADE Pro tools were used to evaluate the risk of bias and certainty of evidence. CONCLUSION Fixed restorations manufactured with additive manufacturing are valid alternatives to subtractive manufacturing in the digital workflow. CLINICAL SIGNIFICANCE Additive manufacturing is an accurate and cost-effective manufacturing method of digital workflow, especially for metal and resin fixed restorations. Once the challenges in ceramics manufacturing are addressed, AM will show more significant promise in the field.
Collapse
Affiliation(s)
- Anna Németh
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Viktória Vitai
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Kata Kelemen
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Brigitta Teutsch
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Radiology, Medical Imaging Centre, Semmelweis University, Budapest, Hungary; Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Gábor Gerber
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Oral Biology, Semmelweis University, Budapest, Hungary
| | - Réka Fazekas
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Restorative Dentistry and Endodontics, Semmelweis University, Budapest, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary; Institute of Pancreatic Diseases, Semmelweis University, Budapest 1083, Hungary
| | - Judit Borbély
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary.
| |
Collapse
|
7
|
Wang S, Dai J, Xu S, Li P, Fouda AM, Yilmaz B, Alhotan A. Surface characteristics, cytotoxicity, and microbial adhesion of 3D-printed hybrid resin-ceramic materials for definitive restoration. J Dent 2025; 152:105436. [PMID: 39488296 DOI: 10.1016/j.jdent.2024.105436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2024] [Revised: 10/23/2024] [Accepted: 10/24/2024] [Indexed: 11/04/2024] Open
Abstract
OBJECTIVE This study investigated the surface properties, cytotoxicity, and microbial adhesion of 3D-printed specimens made from hybrid resin-ceramic materials intended for use in definitive crowns. METHODS Disc-shaped specimens were 3D-printed using six different hybrid resin-ceramic materials recommended for definitive restorations: Crowntec (CT), VarseoSmile Crown Plus (VS), Tera Harz TC-80DP Graphy (TH), C&B Permanent ODS (CB), Formlabs Permanent Crown (FP), and HeyGears (HG). Surface topography, surface roughness, and water contact angle values were measured for each material (n = 6). Cytotoxicity was assessed using direct contact and extract tests on human gingival fibroblasts (n = 4). Additionally, the adhesion of mixed oral bacteria to the surfaces of the specimens was evaluated by counting colony-forming units (CFUs) after a 2-hour incubation period (n = 6). RESULTS The TH group exhibited significantly lower surface roughness (Ra: 0.28 ± 0.13 μm) compared to the other materials (CT: 1.87 ± 0.34 μm; VS: 1.13 ± 0.09 μm; CB: 2.91 ± 0.27 μm; FP: 2.50 ± 0.08 μm; HG: 1.50 ± 0.55 μm). The VS group had the highest water contact angle (129.5 ± 1.1°), indicating greater hydrophobicity, in contrast to the other groups (CT: 72.6 ± 2.1°; TH: 75.0 ± 0.3°; CB: 69.1 ± 0.2°; FP: 93.0 ± 1.6°; HG: 77.7 ± 0.3°). Cytotoxicity testing showed no harmful effects, as relative cell viability exceeded 70 %, and lactate dehydrogenase (LDH) release remained below 30 % for all materials. The TH specimens also demonstrated the lowest bacterial adhesion. CONCLUSIONS The surface characteristics of the tested resin-ceramic materials varied significantly, with TH showing the smoothest surface and the least bacterial adhesion. All materials were found to be non-toxic. Therefore, TH material has the potential to provide definitive restorations with less microbial adhesion. CLINICAL SIGNIFICANCE The type of resin-ceramic material significantly affects the surface properties of 3D-printed specimens. These findings are crucial for selecting the appropriate resin-ceramic material for definitive restorations.
Collapse
Affiliation(s)
- Suya Wang
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, S366 Jiangnan Boulevard, Guangzhou 510280, China
| | - Jingtao Dai
- Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, S366 Jiangnan Boulevard, Guangzhou 510280, China.
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, S366 Jiangnan Boulevard, Guangzhou 510280, China
| | - Ping Li
- Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction & Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou, PR China
| | - Ahmed Mahmoud Fouda
- Department of Oral Technology, Medical Faculty, University Hospital Bonn, 53111, Bonn, North Rhine-Westphalia, Germany; Department of Fixed Prosthodontics, Suez Canal University, Ismailia, Egypt
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, P.O. Box 10219, Riyadh 12372, Saudi Arabia
| |
Collapse
|
8
|
Azpiazu-Flores FX, Johnston WM, Mata-Mata SJ, Yilmaz B. Positional trueness of three removable die designs with different root geometries manufactured using stereolithographic 3D printing. J Prosthet Dent 2025; 133:178-183. [PMID: 37802737 DOI: 10.1016/j.prosdent.2023.08.036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 08/30/2023] [Accepted: 08/31/2023] [Indexed: 10/08/2023]
Abstract
STATEMENT OF PROBLEM Three-dimensional (3D) printed casts are a suitable alternative to dental stone casts. Contemporary dental design computer programs permit designing definitive casts with removable dies with different root geometries and retention mechanisms. Studies on the positional trueness of 3D printed removable dies with different root geometries are lacking. PURPOSE The purpose of this in vitro study was to investigate the 3D displacements of three 3D printed removable die designs with different root geometries. MATERIAL AND METHODS The digital file of a dental stone alveolar cast with root-form removable dies (MOD UJ IV Fixed Prosthetics; Ivoclar AG) was used as a reference to create 3 removable die and alveolar cast designs (Root Form, RF; Conical, CON; Cylindric, CYL) with different root geometries in 2 dental design computer programs (DentalCAD 3.1 Rijeka; exocad; GmbH; InLab CAD 22.0; Dentsply Sirona). 3 equidistant Ø1-mm spheres (C, Cervical; M, Middle; O, Occlusal) were designed on the buccal surface of the coronal portion of the removable die to evaluate their displacement. A total of 45 alveolar casts with 45 removable dies were fabricated using a stereolithographic 3D printer (Form 3; Formlabs); each die group consisted of 15 specimens. After fabrication and postprocessing, the specimens were scanned, and their digital files were analyzed in a metrology-grade computer program to evaluate the displacement of the removable dies with respect to the position of the die in the master reference file. Subsequently, the data were analyzed using a 3-way analysis of variance (ANOVA) followed by step-down Bonferroni-corrected pairwise comparisons (α=.05). RESULTS Two statistically significant 2-way interactions were detected between the independent variables, die design and direction (P<.001), and location and direction (P<.001). The post hoc analysis identified significant differences between the displacement values of RF and CYL (P<.001) and RF and the CON (P<.001) designs on the Y axis. The measured displacements were statistically different between the C and O locations on the Y axis (P=.001) and the M and O locations on the Z axis (P=.006). CONCLUSIONS The root geometry of a 3D printed removable die and alveolar cast can affect seating, and variable degrees of tipping of the removable die can be seen. The seating and congruence of the removable die with the interocclusal space and relationships observed intraorally should be confirmed before adjusting indirect restorations.
Collapse
Affiliation(s)
- Francisco X Azpiazu-Flores
- ITI Scholar, Department of Prosthodontics, School of Dentistry, Indiana Univeristy, Indianapolis, Ind; and Assistant Professor, Department of Restorative Dentistry, Dr. Gerald Niznick College of Dentistry, University of Manitoba, Winnipeg, Canada
| | - William M Johnston
- Professor Emeritus, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio
| | - Severino J Mata-Mata
- Assistant Professor, Faculty of Dentistry, Francisco Marroquín University (UFM), Guatemala City, Guatemala
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, Columbus, Ohio..
| |
Collapse
|
9
|
Rokaya D, Jaghsi AA, Jagtap R, Srimaneepong V. Artificial intelligence in dentistry and dental biomaterials. FRONTIERS IN DENTAL MEDICINE 2024; 5:1525505. [PMID: 39917699 PMCID: PMC11797767 DOI: 10.3389/fdmed.2024.1525505] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2024] [Accepted: 12/06/2024] [Indexed: 02/09/2025] Open
Abstract
Artificial intelligence (AI) technology is being used in various fields and its use is increasingly expanding in dentistry. The key aspects of AI include machine learning (ML), deep learning (DL), and neural networks (NNs). The aim of this review is to present an overview of AI, its various aspects, and its application in biomedicine, dentistry, and dental biomaterials focusing on restorative dentistry and prosthodontics. AI-based systems can be a complementary tool in diagnosis and treatment planning, result prediction, and patient-centered care. AI software can be used to detect restorations, prosthetic crowns, periodontal bone loss, and root canal segmentation from the periapical radiographs. The integration of AI, digital imaging, and 3D printing can provide more precise, durable, and patient-oriented outcomes. AI can be also used for the automatic segmentation of panoramic radiographs showing normal anatomy of the oral and maxillofacial area. Recent advancement in AI in medical and dental sciences includes multimodal deep learning fusion, speech data detection, and neuromorphic computing. Hence, AI has helped dentists in diagnosis, planning, and aid in providing high-quality dental treatments in less time.
Collapse
Affiliation(s)
- Dinesh Rokaya
- Clinical Sciences Department, College of Dentistry, Ajman University, Ajman, United Arab Emirates
- Center of Medical and Bio-Allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
| | - Ahmad Al Jaghsi
- Clinical Sciences Department, College of Dentistry, Ajman University, Ajman, United Arab Emirates
- Center of Medical and Bio-Allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
- Department of Prosthodontics, Gerodontology, and Dental Materials, Greifswald University Medicine, Greifswald, Germany
| | - Rohan Jagtap
- Division of Oral and Maxillofacial Radiology, Department of Care Planning and Restorative Sciences, University of Mississippi Medical Center (UMMC) School of Dentistry, Jackson, MS, United States
| | - Viritpon Srimaneepong
- Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand
| |
Collapse
|
10
|
Auškalnis L, Akulauskas M, Osnes C, Revilla-León M, Kernen-Gintautė A, Rutkūnas V. Trueness of maxillomandibular relationship in 3D-printed and conventional casts. J Dent 2024; 148:105044. [PMID: 38710316 DOI: 10.1016/j.jdent.2024.105044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 04/10/2024] [Accepted: 05/03/2024] [Indexed: 05/08/2024] Open
Abstract
OBJECTIVES To compare the trueness of maxillomandibular relationship between articulated 3D-printed and conventional diagnostic casts in maximum intercuspation (MIP). METHODS Reference casts were articulated in MIP, and scanned using a Coordinate Measurement Machine (CMM, n = 1). Digital scans were made from the reference casts by using an intraoral scanner (IOS, n = 10) (Trios 4; 3Shape A/S). IOS scans were processed to create 3D-printed casts by using MAX UV385 (Asiga) and NextDent 5100 (3DSystems) 3D-printers. The conventional workflow implemented vinylpolysiloxane (VPS) impressions and Type IV stone. Stone and 3D-printed casts were articulated and digitized with a laboratory scanner (E4; 3Shape A/S). The 3D-printed casts were scanned on two occasions: with and without positioning pins. Inter-arch distances and 3D-contact area were measured and compared. Statistical tests used were Shapiro-Wilk, Levene's, Welch's t-test, and 2-way ANOVA (α=0.05). RESULTS IOS group showed similar or better maxillomandibular relationship trueness than stone casts and 3D-printed casts (p < 0.05). 3D-contact area analysis showed similar deviations between 3D-printed and stone casts (p > 0.05). The choice of 3D-printer and presence of positioning pins on the casts significantly influenced maxillomandibular relationship trueness (p < 0.05). CONCLUSIONS Articulated 3D-printed and stone casts exhibited similar maxillomandibular relationship trueness. CLINICAL SIGNIFICANCE Although 3D-printing methods can introduce a considerable amount of deviations, the maxillomandibular relationship trueness of articulated 3D-printed and stone casts in MIP can be considered similar.
Collapse
Affiliation(s)
- Liudas Auškalnis
- PhD student, Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania.
| | - Mykolas Akulauskas
- PhD student, Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania
| | - Cecilie Osnes
- Research Assistant, School of Dentistry, University of Leeds, Leeds, UK
| | - Marta Revilla-León
- DDS, MSD, PhD, Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash and Faculty and Director, Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass, USA
| | - Aistė Kernen-Gintautė
- Dr. med. dent., Medical Center - University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Faculty of Medicine, University of Freiburg, Germany
| | - Vygandas Rutkūnas
- Professor, PhD, Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
| |
Collapse
|
11
|
Lin YC, Tarrazzi D, Schoenbaum T, Knoernschild K. Effect of postprocessing parameters on the flexural strength of vat-polymerized additively manufactured interim fixed dental prostheses: A systematic review with postprocessing guidelines. J Prosthet Dent 2024:S0022-3913(24)00497-9. [PMID: 39142995 DOI: 10.1016/j.prosdent.2024.07.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 07/16/2024] [Accepted: 07/17/2024] [Indexed: 08/16/2024]
Abstract
STATEMENT OF PROBLEM Limited data exist regarding the effects of postprocessing on the flexural strength of vat-polymerized additively manufactured (AM) interim fixed dental prostheses. PURPOSE The purpose of this systematic review was to determine how the postprocessing workflow affects the mechanical properties of vat-polymerized additively manufactured interim fixed dental prostheses and to establish clinical guidelines. MATERIAL AND METHODS The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. The population, intervention, comparison, and outcome (PICO) question was "For vat-polymerized additively manufactured interim fixed dental prostheses (P), does varying the postprocessing workflow/ protocol (I and C) affect mechanical properties/physical properties/flexural strength (O)?" Searches were conducted in 3 databases: PubMed/Medline, EMBASE, and Web of Science, with 2 investigators performing the title and abstract screening and setting the inclusion and exclusion criteria to identify publications. The risk of bias was evaluated by applying the Joanna Briggs Institute Critical Appraisal Checklist for Quasi-Experimental Studies (nonrandomized experimental studies). The reported independent variables of rinse solution, rinse time, and polymerization time on the flexural strength results were extracted for qualitative review. RESULTS The initial search identified 149 records, with 12 in vitro studies meeting the inclusion criteria. Significant heterogeneity was observed in the manufacturing process and materials. Eleven of 12 included studies reported flexural strength above 100 MPa when following the manufacturer's recommendation. Postprocessing rinsing ranged from 5 seconds to 90 minutes, with potentially reduced flexural strength with extended rinsing. A rinse of 5 to 10 minutes was recommended for optimal mechanical properties, degree of conversion, and biocompatibility. Isopropyl alcohol (IPA) and tripropylene glycol monomethyl ether (TPM) were the most investigated rising solutions, while experimental solutions including 99.5% acetone and 100% bio-ethyl alcohol reportedly decreased flexural strength. Polymerization time and intensity correlated positively with the flexural strength, whereas an artificial aging process reduced the flexural strength. CONCLUSIONS Heterogeneity existed in the reported postprocessing protocols for AM interim fixed prostheses, including manufacturer materials, methods, and study outcomes. While polymerization time and intensity correlated with greater strength, consistent patterns regarding rinsing solution or time were lacking. Rinsing solution, extended rinsing time, and artificial aging may reduce flexural strength. Further investigation is indicated.
Collapse
Affiliation(s)
- Yu Chun Lin
- Assistant Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, GA.
| | - Daler Tarrazzi
- Assistant Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, GA
| | - Todd Schoenbaum
- Professor, Department of Restorative Sciences, Dental College of Georgia at Augusta University, Augusta, GA
| | - Kent Knoernschild
- Chair and Professor, Department of Preventive and Restorative Dental Sciences, University of California, San Francisco, San Francisco, Calif
| |
Collapse
|
12
|
Mangano FG, Yang KR, Lerner H, Porrà T, Khachatryan LG, Gordienko ID, Admakin O. 3D-printed short-span hybrid composite implant-supported restorations fabricated through tilting stereolithography: A retrospective clinical study on 85 patients with 1 year of follow-up. J Dent 2024; 147:105095. [PMID: 38788917 DOI: 10.1016/j.jdent.2024.105095] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/12/2024] [Accepted: 05/21/2024] [Indexed: 05/26/2024] Open
Abstract
PURPOSE To report the clinical results obtained with fixed short-span (single crowns [SCs] and fixed partial prostheses [FPPs]) implant-supported hybrid composite restorations fabricated through tilting stereolithography (TSLA). METHODS This retrospective clinical study included 85 patients who had been restored with 95 fixed short-span implant-supported hybrid composite (Irix Max®, DWS Systems) restorations (70 SCs and 25 FPPs up to three units) fabricated with TSLA. The full-digital model-free workflow was based on intraoral implant scanning, computer-assisted design (CAD) and 3D printing using TSLA (Dfab®, DWS Systems). The primary outcomes were the marginal adaptation, the quality of the occlusal and interproximal contact points, and the chromatic integration of the restorations, assessed independently by two experienced operators (a prosthodontist and a periodontist). A score from 1 to 5 (with 5 as the highest value, 4 for satisfactory quality, 3 for acceptable quality, and 2 and 1 as the lowest values, expressing unsatisfactory quality) was assigned by each operator to each restoration at delivery. The secondary outcomes were the survival and success of the restorations at the 1-year follow-up. The restoration was defined as successful in the absence of any complications throughout the follow-up period. A statistical analysis was conducted. RESULTS For the quality of the marginal closure and occlusal and interproximal contact points, the 3D-printed hybrid composite restorations scored highly; the aesthetic integration was satisfactory. One year after placement, all restorations survived, with a low incidence (4.2 % overall, 5.7 % SCs) of complications (two abutment screw loosenings, two decementation of the restorations, and one upper portion of the hybrid abutment decemented from the titanium base), for a success rate of 95.8 %. CONCLUSIONS Within the limits of this study (retrospective design, follow-up limited to 1 year from the delivery, and only cemented restorations included) fixed short-span implant-supported hybrid composite crowns and bridges fabricated through TSLA were clinically precise, presenting a low incidence of complications at 1 year. STATEMENT OF CLINICAL RELEVANCE The use of TSLA printing technology can open new perspectives for the treatment of small edentulous gaps with definitive implant-supported prosthetic restorations.
Collapse
Affiliation(s)
- Francesco Guido Mangano
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, 8-2 Trubetskaya Street, Moscow 119991, Russian Federation.
| | | | - Henriette Lerner
- Academic Teaching and Research Institution of Johann Wolfgang Goethe University, Frankfurt, Germany
| | | | - Lusine G Khachatryan
- Department of Pediatric Diseases, N. F. Filatov Clinical Institute of Children's Health, I. M. Sechenov First State Medical University, Moscow, Russian Federation
| | - Igor Dmitrievich Gordienko
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, 8-2 Trubetskaya Street, Moscow 119991, Russian Federation
| | - Oleg Admakin
- Department of Pediatric, Preventive Dentistry and Orthodontics, I. M. Sechenov First State Medical University, 8-2 Trubetskaya Street, Moscow 119991, Russian Federation
| |
Collapse
|
13
|
Dönmez MB, Kim HT, Lee YH, Jo YH, Yoon HI, Yilmaz B. Effect of barium silicate on mechanical properties, transmittance, and protein adsorption of resin for additive manufacturing containing zwitterionic polymer. J Prosthet Dent 2024; 132:465.e1-465.e8. [PMID: 38890060 DOI: 10.1016/j.prosdent.2024.05.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 05/17/2024] [Accepted: 05/21/2024] [Indexed: 06/20/2024]
Abstract
STATEMENT OF PROBLEM Studies on the effect of barium silicate on the material properties of additively manufactured (AM) resins containing 2-methacryloyloxyethyl phosphorylcholine (MPC) for dental applications are lacking. PURPOSE The purpose of this in vitro study was to evaluate the mechanical properties, transmittance, and protein adsorption of MPC-containing AM resin incorporated with different barium silicate contents and to compare these findings with those of a commercially available unfilled AM resin marketed for definitive restorations. MATERIAL AND METHODS Resins incorporating 6 wt% MPC and 4 different concentrations of barium silicate (10 wt%, MB10; 20 wt%, MB20; 30 wt%, MB30; and 40 wt%, MB40) were prepared. An MPC-containing resin with no filler was also prepared (0 wt%, MBN). Surface roughness (n=15), Vickers hardness (n=15), flexural strength and modulus (n=15), fracture toughness (n=15), transmittance (n=15), and protein adsorption (n=3) of the filled resin specimens were measured and compared with those of commercially available unfilled resin specimens. All data were analyzed using the Kruskal-Wallis and Dunn tests (α=.05). RESULTS All experimental resins had higher surface roughness than the unfilled resin (P≤.048). MB40 had higher hardness, flexural strength, flexural modulus, and fracture toughness than most other groups (P≤.047). MB10 had higher transmittance than most other groups (P≤.012). All experimental resins had lower protein adsorption than the unfilled resin, regardless of the barium silicate content (P≤.023). CONCLUSIONS The experimental resin containing 6 wt% MPC and 40 wt% barium silicate showed better mechanical properties and lower protein adsorption than the resin with no MPC or ceramic fillers. Transmittance decreased with the increase of barium silicate in the resins.
Collapse
Affiliation(s)
- Mustafa Borga Dönmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; and ITI Scholar, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Hyun-Tae Kim
- Graduate student, Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Yun-Hee Lee
- Adjunct Researcher, Dental Research Institute, Seoul National University, Seoul, Republic of Korea; and Senior Researcher, M.O.P. Materials, Seoul, Republic of Korea
| | - Ye-Hyeon Jo
- Senior Researcher, Dental Research Institute, Seoul National University, Seoul, Republic of Korea
| | - Hyung-In Yoon
- Associate Professor, Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, Seoul, Republic of Korea; and Visiting Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; and Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
14
|
Petousis M, Sagris D, Papadakis V, Moutsopoulou A, Argyros A, David C, Valsamos J, Spiridaki M, Michailidis N, Vidakis N. Optimization Course of Titanium Nitride Nanofiller Loading in High-Density Polyethylene: Interpretation of Reinforcement Effects and Performance in Material Extrusion 3D Printing. Polymers (Basel) 2024; 16:1702. [PMID: 38932052 PMCID: PMC11207989 DOI: 10.3390/polym16121702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Revised: 06/11/2024] [Accepted: 06/12/2024] [Indexed: 06/28/2024] Open
Abstract
In this study, titanium nitride (TiN) was selected as an additive to a high-density polyethylene (HDPE) matrix material, and four different nanocomposites were created with TiN loadings of 2.0-8.0 wt. % and a 2 wt. % increase step between them. The mixtures were made, followed by the fabrication of the respective filaments (through a thermomechanical extrusion process) and 3D-printed specimens (using the material extrusion (MEX) technique). The manufactured specimens were subjected to mechanical, thermal, rheological, structural, and morphological testing. Their results were compared with those obtained after conducting the same assessments on unfilled HDPE samples, which were used as the control samples. The mechanical response of the samples improved when correlated with that of the unfilled HDPE. The tensile strength improved by 24.3%, and the flexural strength improved by 26.5% (composite with 6.0 wt. % TiN content). The dimensional deviation and porosity of the samples were assessed with micro-computed tomography and indicated great results for porosity improvement, achieved with 6.0 wt. % TiN content in the composite. TiN has proven to be an effective filler for HDPE polymers, enabling the manufacture of parts with improved mechanical properties and quality.
Collapse
Affiliation(s)
- Markos Petousis
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece; (M.P.); (A.M.); (J.V.); (M.S.)
| | - Dimitris Sagris
- Department of Mechanical Engineering, Serres Campus, International Hellenic University, 62124 Serres, Greece; (D.S.); (C.D.)
| | - Vassilis Papadakis
- Institute of Electronic Structure and Laser of the Foundation for Research and Technology-Hellas (IESL-FORTH)–Hellas, N. Plastira 100 m, 70013 Heraklion, Greece;
- Department of Industrial Design and Production Engineering, University of West Attica, 12243 Athens, Greece
| | - Amalia Moutsopoulou
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece; (M.P.); (A.M.); (J.V.); (M.S.)
| | - Apostolos Argyros
- Physical Metallurgy Laboratory, Mechanical Engineering Department, School of Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (A.A.); (N.M.)
- Centre for Research & Development of Advanced Materials (CERDAM), Centre for Interdisciplinary Research and Innovation, Balkan Centre, Building B’, 10th km Thessaloniki-Thermi Road, 57001 Thessaloniki, Greece
| | - Constantine David
- Department of Mechanical Engineering, Serres Campus, International Hellenic University, 62124 Serres, Greece; (D.S.); (C.D.)
| | - John Valsamos
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece; (M.P.); (A.M.); (J.V.); (M.S.)
| | - Mariza Spiridaki
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece; (M.P.); (A.M.); (J.V.); (M.S.)
| | - Nikolaos Michailidis
- Physical Metallurgy Laboratory, Mechanical Engineering Department, School of Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (A.A.); (N.M.)
- Centre for Research & Development of Advanced Materials (CERDAM), Centre for Interdisciplinary Research and Innovation, Balkan Centre, Building B’, 10th km Thessaloniki-Thermi Road, 57001 Thessaloniki, Greece
| | - Nectarios Vidakis
- Department of Mechanical Engineering, Hellenic Mediterranean University, 71410 Heraklion, Greece; (M.P.); (A.M.); (J.V.); (M.S.)
| |
Collapse
|
15
|
Aronne M, Bertana V, Schimmenti F, Roppolo I, Chiappone A, Cocuzza M, Marasso SL, Scaltrito L, Ferrero S. 3D-Printed MEMS in Italy. MICROMACHINES 2024; 15:678. [PMID: 38930648 PMCID: PMC11205654 DOI: 10.3390/mi15060678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/13/2024] [Accepted: 05/18/2024] [Indexed: 06/28/2024]
Abstract
MEMS devices are more and more commonly used as sensors, actuators, and microfluidic devices in different fields like electronics, opto-electronics, and biomedical engineering. Traditional fabrication technologies cannot meet the growing demand for device miniaturisation and fabrication time reduction, especially when customised devices are required. That is why additive manufacturing technologies are increasingly applied to MEMS. In this review, attention is focused on the Italian scenario in regard to 3D-printed MEMS, studying the techniques and materials used for their fabrication. To this aim, research has been conducted as follows: first, the commonly applied 3D-printing technologies for MEMS manufacturing have been illustrated, then some examples of 3D-printed MEMS have been reported. After that, the typical materials for these technologies have been presented, and finally, some examples of their application in MEMS fabrication have been described. In conclusion, the application of 3D-printing techniques, instead of traditional processes, is a growing trend in Italy, where some exciting and promising results have already been obtained, due to these new selected technologies and the new materials involved.
Collapse
Affiliation(s)
- Matilde Aronne
- ChiLab Laboratory, Politecnico di Torino (PoliTo), Via Lungo Piazza d’Armi 6, 10034 Chivasso, Italy; (M.A.); (M.C.); (S.L.M.); (L.S.); (S.F.)
| | - Valentina Bertana
- ChiLab Laboratory, Politecnico di Torino (PoliTo), Via Lungo Piazza d’Armi 6, 10034 Chivasso, Italy; (M.A.); (M.C.); (S.L.M.); (L.S.); (S.F.)
| | - Francesco Schimmenti
- Department of Applied Science and Technology, Politecnico di Torino (PoliTo), Corso Duca Degli Abruzzi 24, 10129 Turin, Italy;
- Department of Chemistry, Biology and Biotechnology, University of Perugia, Via Elce di Sotto 8, 06123 Perugia, Italy
| | - Ignazio Roppolo
- Department of Applied Science and Technology, Politecnico di Torino (PoliTo), Corso Duca Degli Abruzzi 24, 10129 Turin, Italy;
| | - Annalisa Chiappone
- Department of Chemical and Geological Science, University of Cagliari, Cittadella Universitaria Blocco D, S.S. 554 Bivio per Sestu, 09042 Monserrato, Italy;
| | - Matteo Cocuzza
- ChiLab Laboratory, Politecnico di Torino (PoliTo), Via Lungo Piazza d’Armi 6, 10034 Chivasso, Italy; (M.A.); (M.C.); (S.L.M.); (L.S.); (S.F.)
| | - Simone Luigi Marasso
- ChiLab Laboratory, Politecnico di Torino (PoliTo), Via Lungo Piazza d’Armi 6, 10034 Chivasso, Italy; (M.A.); (M.C.); (S.L.M.); (L.S.); (S.F.)
- CNR-IMEM, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Luciano Scaltrito
- ChiLab Laboratory, Politecnico di Torino (PoliTo), Via Lungo Piazza d’Armi 6, 10034 Chivasso, Italy; (M.A.); (M.C.); (S.L.M.); (L.S.); (S.F.)
| | - Sergio Ferrero
- ChiLab Laboratory, Politecnico di Torino (PoliTo), Via Lungo Piazza d’Armi 6, 10034 Chivasso, Italy; (M.A.); (M.C.); (S.L.M.); (L.S.); (S.F.)
| |
Collapse
|
16
|
Colucci G, Sacchi F, Bondioli F, Messori M. Fully Bio-Based Polymer Composites: Preparation, Characterization, and LCD 3D Printing. Polymers (Basel) 2024; 16:1272. [PMID: 38732741 PMCID: PMC11085923 DOI: 10.3390/polym16091272] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 04/28/2024] [Accepted: 04/30/2024] [Indexed: 05/13/2024] Open
Abstract
The present work aimed to prepare novel bio-based composites by adding fillers coming from agro-wastes to an acrylate epoxidized soybean oil (AESO) resin, using liquid crystal display (LCD) 3D printing. Different photocurable formulations were prepared by varying the reactive diluents, iso-bornyl methacrylate (IBOMA) and tetrahydrofurfuryl acrylate (THFA). Then, two fillers derived from different industrial wastes, corn (GTF) and wine (WPL-CF) by-products, were added to the AESO-based formulations to develop polymer composites with improved properties. The printability by LCD of the photocurable formulations was widely studied. Bio-based objects with different geometries were realized, showing printing accuracy, layer adhesion, and accurate details. The thermo-mechanical and mechanical properties of the 3D-printed composites were tested by TGA, DMA, and tensile tests. The results revealed that the agro-wastes' addition led to a remarkable increase in the elastic modulus, tensile strength, and glass transition temperature in the glassy state for the systems containing IBOMA and for flexible structures in the rubbery region for systems containing THFA. AESO-based polymers demonstrated tunable properties, varying from rigid to flexible, in the presence of different diluents and biofillers. This finding paves the way for the use of this kind of composite in applications, such as biomedical for the realization of prostheses.
Collapse
Affiliation(s)
- Giovanna Colucci
- Politecnico di Torino, Department of Applied Science and Technology (DISAT), Corso Duca degli Abruzzi 24, 10129 Torino, Italy; (F.S.); (F.B.); (M.M.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Francesca Sacchi
- Politecnico di Torino, Department of Applied Science and Technology (DISAT), Corso Duca degli Abruzzi 24, 10129 Torino, Italy; (F.S.); (F.B.); (M.M.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Federica Bondioli
- Politecnico di Torino, Department of Applied Science and Technology (DISAT), Corso Duca degli Abruzzi 24, 10129 Torino, Italy; (F.S.); (F.B.); (M.M.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| | - Massimo Messori
- Politecnico di Torino, Department of Applied Science and Technology (DISAT), Corso Duca degli Abruzzi 24, 10129 Torino, Italy; (F.S.); (F.B.); (M.M.)
- National Interuniversity Consortium of Materials Science and Technology (INSTM), Via G. Giusti 9, 50121 Firenze, Italy
| |
Collapse
|
17
|
Azpiazu-Flores FX, Morton D, Lin WS. Accelerated denture base festooning using a free 3D modeling computer program: A dental technique. J Prosthet Dent 2024; 131:981-982. [PMID: 38052696 DOI: 10.1016/j.prosdent.2023.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 12/07/2023]
Affiliation(s)
- Francisco X Azpiazu-Flores
- ITI Scholar, Center for Implant, Esthetic and Innovative Dentistry, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind.
| | - Dean Morton
- Professor and Co-Director, Center for Implant, Esthetic and Innovative Dentistry, Indiana University School of Dentistry, Indianapolis, Ind
| | - Wei-Shao Lin
- Professor and Chair, Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Ind
| |
Collapse
|
18
|
Palaszkó D, Németh A, Török G, Vecsei B, Vánkos B, Dinya E, Borbély J, Marada G, Hermann P, Kispélyi B. Trueness of five different 3D printing systems including budget- and professional-grade printers: An In vitro study. Heliyon 2024; 10:e26874. [PMID: 38468926 PMCID: PMC10925989 DOI: 10.1016/j.heliyon.2024.e26874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/13/2024] Open
Abstract
Problem Several types of 3D printers with different techniques and prices are available on the market. However, results in the literature are inconsistent, and there is no comprehensive agreement on the accuracy of 3D printers of different price categories for dental applications. Aim This study aimed to investigate the accuracy of five different 3D printing systems, including a comparison of budget- and higher-end 3D printing systems, according to a standardized production and evaluation protocol. Material and methods A maxillary reference model with prepared teeth was created using 16 half-ball markers with a diameter of 1 mm to facilitate measurements. A reference file was fabricated using five different 3D printers. The printed models were scanned and superimposed onto the original standard tesselation language (.stl) file, and digital measurements were performed to assess the 3-dimensional and linear deviations between the reference and test models. Results After examining the entire surface of the models, we found that 3D printers using Fused filament fabrication (FFF) technology -120.2 (20.3) μm create models with high trueness but high distortion. Distortions along the z-axis were found to be the highest with the stereolithography (SLA)-type 3D printer at -153.7 (38.7) μm. For the 4-unit FPD, we found 201.9 (41.8) μm deviation with the digital light processing (DLP) printer. The largest deviation (-265.1 (55.4) μm) between the second molars was observed for the DLP printer. Between the incisor and the second molar, the best results were produced by the FFF printer with -30.5 (76.7) μm. Conclusion Budget-friendly 3D printers are comparable to professional-grade printers in terms of precision. In general, the cost of a printing system is not a reliable indicator of its level of accuracy.
Collapse
Affiliation(s)
- Dénes Palaszkó
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Anna Németh
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Gréta Török
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Bálint Vecsei
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Boldizsár Vánkos
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Elek Dinya
- Institute of Digital Health Sciences, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | | | - Péter Hermann
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| | - Barbara Kispélyi
- Department of Prosthodontics, Faculty of Dentistry, Semmelweis University, Budapest, Hungary
| |
Collapse
|
19
|
An H. Ceramic veneer shade evaluation using a multicolored 3D-printed model-A case report. J ESTHET RESTOR DENT 2024; 36:415-420. [PMID: 37737648 DOI: 10.1111/jerd.13138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 07/18/2023] [Accepted: 09/10/2023] [Indexed: 09/23/2023]
Abstract
OBJECTIVE This article demonstrates the use of a multicolored 3D-printed model for laboratory shade evaluation of ceramic veneers. CLINICAL CONSIDERATIONS A young female patient presented with peg lateral incisors and diastemata between her maxillary incisors. Four ceramic veneers for her maxillary incisors were fabricated using a digital workflow. A multicolored 3D-printed model was manufactured using material jetting technology. The multicolored model and try-in pastes were used to evaluate and adjust the shade of the veneers. Clinically acceptable color matching was achieved, the veneers were delivered without further chairside shade adjustments. CONCLUSIONS Successful color evaluation and adjustment were achieved using the combination of multicolored 3D-printed model and try-in pastes. The use of this approach saved time for stump shade taking and fabrication of tooth-colored dies. CLINICAL SIGNIFICANCE A multicolored 3D-printed model can be a useful tool for color evaluation and adjustment of ceramic restorations.
Collapse
Affiliation(s)
- Hongseok An
- Department of Oral Rehabilitation and Biosciences, Oregon Health & Science University School of Dentistry, Portland, Oregon, USA
| |
Collapse
|
20
|
Mangano FG, Cianci D, Pranno N, Lerner H, Zarone F, Admakin O. Trueness, precision, time-efficiency and cost analysis of chairside additive and subtractive versus lab-based workflows for manufacturing single crowns: An in vitro study. J Dent 2024; 141:104792. [PMID: 38013004 DOI: 10.1016/j.jdent.2023.104792] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 11/21/2023] [Accepted: 11/23/2023] [Indexed: 11/29/2023] Open
Abstract
PURPOSE To evaluate the trueness, precision, time efficiency, and cost of three different workflows for manufacturing single crowns (SCs). METHODS A plaster model with a prepared tooth (#15) was scanned with an industrial scanner, and an SC was designed in computer-assisted-design (CAD) software. Ten SCs were printed with a hybrid composite (additive chairside) and a stereolithographic (SLA) printer (Dfab®), 10 SCs were milled in lithium disilicate (subtractive chairside) using a chairside milling unit (inLab MC XL®), and 10 SCs were milled in zirconia (lab-based) using a five-axis laboratory machine (DWX-52D®). All SCs were scanned with the same scanner after polymerization/sinterization. Each scan was superimposed to the marginal area of the original CAD file to evaluate trueness: absolute average (ABS AVG), root mean square (RMS), and (90˚-10˚)/2 percentile were calculated for each group. Marginal adaptation and quality of the occlusal and interproximal contact points were also investigated by two prosthodontists on 3D printed and plaster models. Finally, the three workflows' time efficiency and costs were evaluated. RESULTS Additive chairside and subtractive lab-based SCs had significantly better marginal trueness than subtractive chairside SCs in all three parameters (ABS AVG, p < 0.01; RMS, p < 0.01; [90˚-10˚]/2, p < 0.01). However, the two prosthodontists found no significant differences between the three manufacturing procedures in the quality of the marginal closure (p = 0.186), interproximal (p = 0.319), and occlusal contacts (p = 0.218). Both time efficiency and cost show a trend favoring the chairside additive workflow. CONCLUSIONS Chairside additive technology seems to represent a valid alternative for manufacturing definitive SCs, given the high marginal trueness, precision, workflow efficiency and low costs. STATEMENT OF CLINICAL RELEVANCE Additive chairside manufacturing of definitive hybrid composite SCs is now possible and shows high accuracy, time efficiency, and competitive cost.
Collapse
Affiliation(s)
- Francesco Guido Mangano
- Department of Pediatric, Preventive Dentistry and Orthodontics, Sechenov First State Medical University, Moscow, Russia.
| | | | - Nicola Pranno
- Department of Oral and Maxillofacial Sciences, Sapienza University, Rome, Italy
| | - Henriette Lerner
- Department of Oral, Maxillofacial and Plastic Surgery, Goethe University, Frankfurt, Germany
| | - Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University Federico II, Naples, Italy
| | - Oleg Admakin
- Department of Pediatric, Preventive Dentistry and Orthodontics, Sechenov First State Medical University, Moscow, Russia
| |
Collapse
|
21
|
Heboyan A, Yazdanie N, Ahmed N. Glimpse into the future of prosthodontics: The synergy of artificial intelligence. World J Clin Cases 2023; 11:7940-7942. [PMID: 38075567 PMCID: PMC10698409 DOI: 10.12998/wjcc.v11.i33.7940] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/26/2023] [Accepted: 11/17/2023] [Indexed: 11/24/2023] Open
Abstract
Prosthodontics, deals in the restoration and replacement of missing and structurally compromised teeth, this field has been remarkably transformed in the last two decades. Through the integration of digital imaging and three-dimensional printing, prosthodontics has evolved to provide more durable, precise, and patient-centric outcome. However, as we stand at the convergence of technology and healthcare, a new era is emerging, one that holds immense promise for the field and that is artificial intelligence (AI). In this paper, we explored the fascinating challenges and prospects associated with the future of prosthodontics in the era of AI.
Collapse
Affiliation(s)
- Artak Heboyan
- Department of Prosthodontics, Yerevan State Medical University after Mkhitar Heratsi, Yerevan 0025, Armenia
| | - Nazia Yazdanie
- Department of Prosthodontics, FMH College of Medicine and Dentistry, Lahore 54000, Pakistan
| | - Naseer Ahmed
- Department of Prosthodontics, Altammash Institute of Dental Medicine, Karachi 75500, Pakistan
| |
Collapse
|
22
|
Cameron AB, Abdelhamid HMHAS, George R. CBCT Segmentation and Additive Manufacturing for the Management of Root Canals with Ledges: A Case Report and Technique. J Endod 2023; 49:1570-1575. [PMID: 37582414 DOI: 10.1016/j.joen.2023.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/06/2023] [Accepted: 08/06/2023] [Indexed: 08/17/2023]
Abstract
Cone-beam computed tomography (CBCT) assessment of a ledge could be useful to a clinician; however, using this information effectively during a treatment procedure can be challenging. Advanced additive manufacturing technologies combined with semi-automated segmentation of root canals can help simulate the ledge and help in management of these iatrogenic complications. A patient presented after unsuccessful root canal treatment with a ledge on the left mandibular first molar. A CBCT was taken, and the images imported into a segmentation software (Mimics, Materialise). The canal was isolated, and segmentation performed along with the other structures of the tooth. A 3-dimensional digital model of the internal structures of the canal were used to design a mock-up which was additively manufactured. This was used as a preclinical guide to simulate the procedure, precurve the file, and manage the canal. This novel technique using virtual modeling from CBCT data post ledge formation allowed for successful and quick management of a tooth with ledges.
Collapse
Affiliation(s)
- Andrew B Cameron
- School of Medicine and Dentistry, Griffith University, Gold Coast, Australia; Menzies Health Institute Queensland Disability & Rehabilitation Center, Gold Coast, Australia
| | | | - Roy George
- School of Medicine and Dentistry, Griffith University, Gold Coast, Australia.
| |
Collapse
|
23
|
Chen Y, Li H, Zhai Z, Nakano T, Ishigaki S. Impact of internal design on the accuracy of 3-dimensionally printed casts fabricated by stereolithography and digital light processing technology. J Prosthet Dent 2023; 130:381.e1-381.e7. [PMID: 37482533 DOI: 10.1016/j.prosdent.2023.06.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 06/27/2023] [Accepted: 06/29/2023] [Indexed: 07/25/2023]
Abstract
STATEMENT OF PROBLEM Altering the internal design of 3-dimensionally (3D) printed dental casts may help to reduce material and time consumption. However, it remains unclear whether such changes would compromise the accuracy of the casts. Further research is also needed to determine the optimal internal design that would maximize printing accuracy. PURPOSE The purpose of this in vitro study was to evaluate the impact of internal design on the accuracy (trueness and precision) of 3D printed dental casts fabricated by stereolithography (SLA) and digital light processing (DLP) technology. MATERIAL AND METHODS A reference digital cast was obtained by scanning a maxillary typodont with an intraoral scanner to create 4 types of internal designs, including hollow interior with perforated base (HWB), hollow interior without base (HB), all solid (S), and internal support structure with perforated base (SWB). Digital casts with different internal designs were printed by two 3D printers with different technologies (SLA and DLP). The printed casts were scanned by a desktop scanner to obtain standard tessellation language (STL) format research digital casts. All reference and research digital casts were imported into a software program for comparison and analysis of accuracy. Differences between the reference and research digital casts were quantitatively indicated by the root mean square (RMS) value. The Kruskal-Wallis 1-way ANOVA was used to test significant differences between the different internal design types and the Mann-Whitney U test was used to test significant differences between the two 3D printers (α=.05). RESULTS The Kruskal-Wallis 1-way ANOVA revealed significant differences in the trueness and precision of different internal design types (all P<.001) for casts printed by both 3D printers. The trueness and precision were significantly worse for the HB design than for the other design types for casts printed by both 3D printers (all P<.05). Regardless of the design type, the trueness was significantly better for casts printed by the SLA-based printer than for casts printed by the DLP-based printer (all P<.05). The precision was significantly worse for casts printed by the SLA-based printer than for casts printed by the DLP-based printer (all P<.05). CONCLUSIONS The internal design may affect the accuracy of 3D printing. The base is necessary to ensure the accuracy of 3D printed dental casts, whereas the internal support structure did not affect the accuracy of 3D printed dental casts. An all-solid design led to higher precision, but not higher trueness. Dental casts printed with SLA technology have higher trueness and lower precision than those printed with DLP technology.
Collapse
Affiliation(s)
- Yuming Chen
- PhD student, Department of Fixed Prosthodontics, Osaka University, Graduate School of Dentistry, Osaka, Japan
| | - Hefei Li
- PhD student, Department of Biomaterials Science, Osaka University, Graduate School of Dentistry, Osaka, Japan
| | - Zhihao Zhai
- Clinical fellow, Department of Fixed Prosthodontics, Osaka University, Graduate School of Dentistry, Osaka, Japan
| | - Tamaki Nakano
- Assistant Professor, Department of Fixed Prosthodontics, Osaka University, Graduate School of Dentistry, Osaka, Japan.
| | - Shoichi Ishigaki
- Associate Professor, Department of Fixed Prosthodontics, Osaka University, Graduate School of Dentistry, Osaka, Japan
| |
Collapse
|
24
|
Németh A, Vitai V, Czumbel ML, Szabó B, Varga G, Kerémi B, Hegyi P, Hermann P, Borbély J. Clear guidance to select the most accurate technologies for 3D printing dental models - A network meta-analysis ✰. J Dent 2023; 134:104532. [PMID: 37120090 DOI: 10.1016/j.jdent.2023.104532] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 03/20/2023] [Accepted: 04/25/2023] [Indexed: 05/01/2023] Open
Abstract
OBJECTIVES Thus far, the findings of numerous studies conducted on the accuracy of three-dimensional (3D) printed dental models are conflicting. Therefore, the aim of the network meta-analysis (NMA) is to determine the accuracy of 3D printed dental models compared with digital reference models. DATA Studies comparing the accuracy of 3D printed full-arch dental models manufactured using different printing techniques to initial STL files were included. SOURCES This study was registered in PROSPERO (CRD42021285863). An electronic search was performed across four databases in November 2021, and search was restricted to the English language. STUDY SELECTION A systematic search was conducted based on a prespecified search query. 16,303 articles were pooled after the removal of the duplicates. Following study selection and data extraction, 11 eligible studies were included in the NMA in 6 subgroups. The outcomes were specified as trueness and precision and expressed as root mean square (RMS) and absolute mean deviation values. Seven printing technologies were analyzed: stereolithography (SLA), digital light processing (DLP), fused deposition modeling/fused filament fabrication (FDM/FFF), MultiJet, PolyJet, continuous liquid interface production (CLIP), and LCD technology. The QUADAS-2 and GRADE were used to evaluate the risk of bias and certainty of evidence. CONCLUSIONS SLA, DLP, and PolyJet technologies were the most accurate in producing full-arch dental models. CLINICAL SIGNIFICANCE The findings of the NMA suggest that SLA, DLP, and PolyJet technologies are sufficiently accurate for full-arch dental model production for prosthodontic purposes. In contrast, FDM/FFF, CLIP, and LCD technologies are less suitable for manufacturing dental models.
Collapse
Affiliation(s)
- Anna Németh
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Viktória Vitai
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Márk László Czumbel
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Periodontology, Semmelweis University, Budapest, Hungary
| | - Bence Szabó
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
| | - Gábor Varga
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Oral Biology, Semmelweis University, Budapest, Hungary
| | - Beáta Kerémi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Restorative Dentistry and Endodontics, Semmelweis University, Budapest, Hungary
| | - Péter Hegyi
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Division of Pancreatic Diseases, Heart and Vascular Center, Semmelweis University, Budapest, Hungary; Institute for Translational Medicine, Medical School, University of Pécs, Pécs, Hungary
| | - Péter Hermann
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary
| | - Judit Borbély
- Centre for Translational Medicine, Semmelweis University, Budapest, Hungary; Department of Prosthodontics, Semmelweis University, Budapest, Hungary.
| |
Collapse
|
25
|
Celik HK, Koc S, Kustarci A, Caglayan N, Rennie AE. The state of additive manufacturing in dental research - A systematic scoping review of 2012-2022. Heliyon 2023; 9:e17462. [PMID: 37484349 PMCID: PMC10361388 DOI: 10.1016/j.heliyon.2023.e17462] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/08/2023] [Accepted: 06/19/2023] [Indexed: 07/25/2023] Open
Abstract
Background/purpose Additive manufacturing (AM), also known as 3D printing, has the potential to transform the industry. While there have been advancements in using AM for dental restorations, there is still a need for further research to develop functional biomedical and dental materials. It's crucial to understand the current status of AM technology and research trends to advance dental research in this field. The aim of this study is to reveal the current status of international scientific publications in the field of dental research related to AM technologies. Materials and methods In this study, a systematic scoping review was conducted using appropriate keywords within the scope of international scientific publishing databases (PubMed and Web of Science). The review included related clinical and laboratory research, including both human and animal studies, case reports, review articles, and questionnaire studies. A total of 187 research studies were evaluated for quantitative synthesis in this review. Results The findings highlighted a rising trend in research numbers over the years (From 2012 to 2022). The most publications were produced in 2020 and 2021, with annual percentage increases of 25.7% and 26.2%, respectively. The majority of AM-related publications in dentistry research originate from Korea. The pioneer dental sub-fields with the ost publications in its category are prosthodontics and implantology, respectively. Conclusion The final review result clearly stated an expectation for the future that the research in dentistry would concentrate on AM technologies in order to increase the new product and process development in dental materials, tools, implants and new generation modelling strategy related to AM. The results of this work can be used as indicators of trends related to AM research in dentistry and/or as prospects for future publication expectations in this field.
Collapse
Affiliation(s)
- H. Kursat Celik
- Dept. of Agr. Machinery and Technology Engineering, Akdeniz University, Antalya, 07070, Turkey
| | - Simay Koc
- Dept. of Endodontics, Fac. of Dentistry, Akdeniz University, Antalya, Turkey
| | - Alper Kustarci
- Dept. of Endodontics, Fac. of Dentistry, Akdeniz University, Antalya, Turkey
| | - Nuri Caglayan
- Dept. of Mechatronics, Fac. of Engineering, Akdeniz University, Antalya, Turkey
| | | |
Collapse
|
26
|
Lankes V, Reymus M, Mayinger F, Coldea A, Liebermann A, Hoffmann M, Stawarczyk B. Three-Dimensional Printed Resin: Impact of Different Cleaning Protocols on Degree of Conversion and Tensile Bond Strength to a Composite Resin Using Various Adhesive Systems. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093580. [PMID: 37176461 PMCID: PMC10179867 DOI: 10.3390/ma16093580] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/03/2023] [Accepted: 05/05/2023] [Indexed: 05/15/2023]
Abstract
The present investigation tested the effect of cleaning methods and adhesives on the tensile bond strength (TBS) of a resin-based composite luted to a temporary 3D printed resin. Substrates (n= 360) were printed using a Rapidshape D20II and cleaned with a butyldiglycol-based solution, isopropanol, or by centrifugation. Specimens were air-abraded with Al2O3 (mean particle size 50 µm) at 0.1 MPa followed by pretreatment (n = 30/subgroup) with: (1) Clearfil Ceramic Primer (CCP); (2) Clearfil Universal Bond (CUB); (3) Scotchbond Universal Plus (SUP) or 4. Visio.link (VL) and luted to PanaviaV5. TBS (n = 15/subgroup) was measured initially (24 h at 37 °C water) or after thermal cycling (10,000×, 5/55 °C). The degree of conversion (DC) for each cleaning method was determined prior and after air-abrasion. Univariate ANOVA followed by post-hoc Scheffé test was computed (p < 0.05). Using Ciba-Geigy tables and chi-square, failure types were analyzed. The DC values were >85% after all cleaning methods, with centrifugation showing the lowest. CCP pretreatment exhibited the lowest TBS values, with predominantly adhesive failures. The combination of CCP and centrifugation increased the TBS values (p < 0.001) compared to the chemical cleaning. CUB, SUP, and VL, regardless of cleaning, can increase the bond strength between the 3D printed resin and the conventional luting resin.
Collapse
Affiliation(s)
- Valerie Lankes
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Marcel Reymus
- Department of Conservative Dentistry and Peridontology, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Felicitas Mayinger
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Andrea Coldea
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Anja Liebermann
- Head of the Department of Prosthetic Dentistry, Faculty of Medicine and University Hospital Cologne, 50931 Cologne, Germany
| | - Moritz Hoffmann
- Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| | - Bogna Stawarczyk
- Scientific Head Dental Material Unit, Department of Prosthetic Dentistry, University Hospital, LMU Munich, 80336 Munich, Germany
| |
Collapse
|
27
|
Juri AZ, Belli R, Lohbauer U, Ebendorff-Heidepriem H, Yin L. Edge chipping damage in lithium silicate glass-ceramics induced by conventional and ultrasonic vibration-assisted diamond machining. Dent Mater 2023:S0109-5641(23)00091-X. [PMID: 37076403 DOI: 10.1016/j.dental.2023.04.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 03/30/2023] [Accepted: 04/05/2023] [Indexed: 04/21/2023]
Abstract
OBJECTIVES Diamond machining of lithium silicate glass-ceramics (LS) induces extensive edge chipping damage, detrimentally affecting LS restoration functionality and long-term performance. This study approached novel ultrasonic vibration-assisted machining of pre-crystallized and crystallized LS materials to investigate induced edge chipping damage in comparison with conventional machining. METHODS The vibration-assisted diamond machining was conducted using a five-axis ultrasonic high-speed grinding/machining machine at different vibration amplitudes while conventional machining was performed using the same machine without vibration assistance. LS microstructural characterization and phase development were performed using scanning electron microscopy (SEM) and x-ray diffraction (XRD) techniques. Machining-induced edge chipping depths, areas and morphology were also characterized using the SEM and Java-based imaging software. RESULTS All machining-induced edge chipping damages resulted from brittle fractures. The damage scales, however, depended on the material microstructures; mechanical properties associated with the fracture toughness, critical strain energy release rates, brittleness indices, and machinability indices; and ultrasonic vibration amplitudes. Pre-crystallized LS with more glass matrix and lithium metasilicate crystals yielded respective 1.8 and 1.6 times greater damage depths and specific damage areas than crystallized LS with less glass matrix and tri-crystal phases in conventional machining. Ultrasonic machining at optimized amplitudes diminished such damages by over 50 % in pre-crystallized LS and up to 13 % in crystallized LS. SIGNIFICANCE This research highlights that ultrasonic vibration assistance at optimized conditions may advance current dental CAD/CAM machining techniques by significant suppression of edge chipping damage in pre-crystallized LS.
Collapse
Affiliation(s)
- Afifah Z Juri
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide 5005, SA, Australia.
| | - Renan Belli
- Research Laboratory for Dental Biomaterials, Dental Clinic 1 - Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Ulrich Lohbauer
- Research Laboratory for Dental Biomaterials, Dental Clinic 1 - Operative Dentistry and Periodontology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Heike Ebendorff-Heidepriem
- Institute for Photonics and Advanced Sensing (IPAS) and School of Physics, Chemistry and Earth Sciences, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Ling Yin
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide 5005, SA, Australia.
| |
Collapse
|
28
|
Wang L, Yuan J, Wu Q, Chen G. Developing a Quality Evaluation System for Color Reproduction of Color 3D Printing Based on MATLAB Multi-Metrics. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2424. [PMID: 36984304 PMCID: PMC10058301 DOI: 10.3390/ma16062424] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 03/10/2023] [Accepted: 03/14/2023] [Indexed: 06/18/2023]
Abstract
Color 3D printing has been widely used in many fields such as cultural, medical, industrial, and food. The color reproduction accuracy of 3D printed products in these fields is becoming increasingly demanding, which requires more reproduction methods and practical tools. At present, most color 3D printing devices use one quantitative index, that is, color difference, to directly predict the color reproduction quality. However, this single quantitative index is not optimal for the curved surface of 3D printed color objects. Based on color evaluation principles, in this study, five new quantitative metrics consisting of color gamut comparison index, color SSIM index, color FSIM index, iCID index, and subjective scaling values are proposed for comparison, and the corresponding GUI design and code implementation of new color quality evaluation system are performed by MATLAB. Moreover, the comprehensive color assessment of color 3D printed products is confirmed by utilizing standard image acquisition and microscopic imaging methods that are not limited to printing materials and sampling locations. The operation of this system is validated to provide interactivity, simplicity and high efficiency. As a result, the system can provide new valuable feedback for color separation and output calibration of color 3D printing devices.
Collapse
Affiliation(s)
- Liru Wang
- State Key Laboratory of Pulp and Paper Engineering, South China University of Technology, Guangzhou 510640, China
| | - Jiangping Yuan
- College of Communication and Art Design, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Qinghua Wu
- College of Communication and Art Design, University of Shanghai for Science and Technology, Shanghai 200093, China
| | - Guangxue Chen
- State Key Laboratory of Pulp and Paper Engineering, South China University of Technology, Guangzhou 510640, China
| |
Collapse
|
29
|
Dai J, Li P, Spintzyk S, Liu C, Xu S. Influence of additive manufacturing method and build angle on the accuracy of 3D-printed palatal plates. J Dent 2023; 132:104449. [PMID: 36773740 DOI: 10.1016/j.jdent.2023.104449] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 01/16/2023] [Accepted: 02/08/2023] [Indexed: 02/11/2023] Open
Abstract
OBJECTIVES In this in vitro study, the effects of additive manufacturing (AM) methods and build angles on the trueness and precision of 3D-printed palatal plate orthodontic appliances for newborns and infants were examined. METHODS Specimens were fabricated by different representative AM methods, including digital light processing (DLP), fused filament fabrication (FFF), and MultiJet printing (MJP). Three build angles (0°, 45°, and 90°) were used. After scanning, all specimens were analyzed using the 3D inspection software. The root mean square values were measured for trueness and precision. Color maps were created to detect deviations in samples. The data were statistically analyzed with a two-way ANOVA. RESULTS The trueness and precision were statistically influenced by both AM methods and build angles (p < 0.05). Moreover, the root mean square values of the 45° DLP (0.0221 ± 0.0017 μm) and the 0° MJP (0.0217 ± 0.0014 μm) were significantly lower compared to those in other groups (p < 0.001). CONCLUSIONS AM methods (DLP, FFF, and MJP) and build angles (0°, 45°, and 90°) significantly impacted the dimensional accuracy of additively manufactured palatal plate orthodontic appliances. Also, the 45° DLP and the 0° MJP were associated with the highest trueness and precision. CLINICAL SIGNIFICANCE All tested AM methods with different build angles yielded clinically acceptable outcomes (within an acceptance range of ±300 μm for trueness), achieving the highest accuracy with a technology-specific suitable build angle.
Collapse
Affiliation(s)
- Jingtao Dai
- Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Ping Li
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China
| | - Sebastian Spintzyk
- ADMiRE Reseach Center - Additive Manufacturing, intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Europastraße 4, Villach 9524, Austria
| | - Chufeng Liu
- Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China.
| | - Shulan Xu
- Center of Oral Implantology, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China.
| |
Collapse
|
30
|
Mau R, Seitz H. Influence of the Volatility of Solvent on the Reproducibility of Droplet Formation in Pharmaceutical Inkjet Printing. Pharmaceutics 2023; 15:pharmaceutics15020367. [PMID: 36839689 PMCID: PMC9965695 DOI: 10.3390/pharmaceutics15020367] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Revised: 01/14/2023] [Accepted: 01/18/2023] [Indexed: 01/24/2023] Open
Abstract
Drop-on-demand (DOD) inkjet printing enables exact dispensing and positioning of single droplets in the picoliter range. In this study, we investigate the long-term reproducibility of droplet formation of piezoelectric inkjet printed drug solutions using solvents with different volatilities. We found inkjet printability of EtOH/ASA drug solutions is limited, as there is a rapid forming of drug deposits on the nozzle of the printhead because of fast solvent evaporation. Droplet formation of c = 100 g/L EtOH/ASA solution was affected after only a few seconds by little drug deposits, whereas for c = 10 g/L EtOH/ASA solution, a negative affection was observed only after t = 15 min, while prominent drug deposits form at the printhead tip. Due to the creeping effect, the crystallizing structures of ASA spread around the nozzle but do not clog it necessarily. When there is a negative affection, the droplet trajectory is affected the most, while the droplet volume and droplet velocity are influenced less. In contrast, no formation of drug deposits could be observed for highly concentrated, low volatile DMSO-based drug solution of c = 100 g/L even after a dispensing time of t = 30 min. Therefore, low volatile solvents are preferable to highly volatile solvents to ensure a reproducible droplet formation in long-term inkjet printing of highly concentrated drug solutions. Highly volatile solvents require relatively low drug concentrations and frequent printhead cleaning. The findings of this study are especially relevant when high droplet positioning precision is desired, e.g., drug loading of microreservoirs or drug-coating of microneedle devices.
Collapse
Affiliation(s)
- Robert Mau
- Microfluidics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Justus-von-Liebig Weg 6, 18059 Rostock, Germany
- Correspondence: ; Tel.: +49-381-498-9103
| | - Hermann Seitz
- Microfluidics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Justus-von-Liebig Weg 6, 18059 Rostock, Germany
- Department Life, Light & Matter, Interdisciplinary Faculty, University of Rostock, Albert-Einstein-Str. 25, 18059 Rostock, Germany
| |
Collapse
|
31
|
Huang S, Wei H, Li D. Additive manufacturing technologies in the oral implant clinic: A review of current applications and progress. Front Bioeng Biotechnol 2023; 11:1100155. [PMID: 36741746 PMCID: PMC9895117 DOI: 10.3389/fbioe.2023.1100155] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Accepted: 01/11/2023] [Indexed: 01/21/2023] Open
Abstract
Additive manufacturing (AM) technologies can enable the direct fabrication of customized physical objects with complex shapes, based on computer-aided design models. This technology is changing the digital manufacturing industry and has become a subject of considerable interest in digital implant dentistry. Personalized dentistry implant treatments for individual patients can be achieved through Additive manufacturing. Herein, we review the applications of Additive manufacturing technologies in oral implantology, including implant surgery, and implant and restoration products, such as surgical guides for implantation, custom titanium meshes for bone augmentation, personalized or non-personalized dental implants, custom trays, implant casts, and implant-support frameworks, among others. In addition, this review also focuses on Additive manufacturing technologies commonly used in oral implantology. Stereolithography, digital light processing, and fused deposition modeling are often used to construct surgical guides and implant casts, whereas direct metal laser sintering, selective laser melting, and electron beam melting can be applied to fabricate dental implants, personalized titanium meshes, and denture frameworks. Moreover, it is sometimes required to combine Additive manufacturing technology with milling and other cutting and finishing techniques to ensure that the product is suitable for its final application.
Collapse
Affiliation(s)
| | - Hongbo Wei
- State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, Shaanxi, China
| | - Dehua Li
- State Key Laboratory of Military Stomatology, National Clinical Research Center for Oral Diseases, Shaanxi Engineering Research Center for Dental Materials and Advanced Manufacture, Department of Oral Implants, School of Stomatology, The Fourth Military Medical University, Xi’an, Shaanxi, China
| |
Collapse
|
32
|
New Approach for Extrusion Additive Manufacturing of Soft and Elastic Articles from Liquid-PVC-Based Consumable Materials. Polymers (Basel) 2022; 14:polym14214683. [DOI: 10.3390/polym14214683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 11/06/2022] Open
Abstract
The article deals with the experimental development of a novel additive manufacturing (AM) process using a liquid consumable based on polyvinyl chloride plastisol. A conventional additive manufacturing system designed for deposition of melt filaments was converted to deposition of liquid material. Additive manufacturing with liquid plastisol enables the production of parts with low Shore A hardness and high ductility, surpassing the performance of the conventional filament process. The novel AM process enables the production of articles with a Shore A hardness of 5 to 60, and the mechanical properties of the additively manufactured articles are similar to those produced in the mold. This was achieved by varying the parameters of the AM process as well as the composition of the plastisol composition, including those filled with an inorganic filler. The application of different material distribution patterns also has a significant effect on the mechanical properties of the samples. A potential application of the investigated AM method was proposed and practically evaluated.
Collapse
|
33
|
Abstract
Although the accuracy of direct digitization of oral structure has been improved, indirect digitization is still required in specific situations such as full-arch scanning. Once accurate images are imported, efficient designing can be achieved by CAD software. Although smile design using a 3-dimensional facial scan better predicts planned restorations, further improvement in virtual articulators is needed for complex cases. Computer-aided manufacturing can be offered in several formats such as chairside, laboratory, or centralized fabrications. The subtractive technique is mainly used for restorations, and many chairside CAM materials are available now, but the additive technique has the potential to save materials and an advantage in fabricating complex geometries. Limited evidence is available in applying CAD/CAM technologies in implant restorations. However, it is used to fabricate custom implant abutments and crowns from various materials such as titanium, zirconia, and PEEK and hybrid crowns using stock titanium base abutments.
Collapse
Affiliation(s)
- Hidehiko Watanabe
- Restorative Dentistry, Oregon Health & Science University, School of Dentistry, 2730 S Moody Avenue, Portland, OR 97201-5042, USA.
| | - Christopher Fellows
- Restorative Dentistry, Oregon Health & Science University, School of Dentistry, 2730 S Moody Avenue, Portland, OR 97201-5042, USA
| | - Hongseok An
- Restorative Dentistry, Oregon Health & Science University, School of Dentistry, 2730 S Moody Avenue, Portland, OR 97201-5042, USA
| |
Collapse
|