1
|
Castro AL, Gonçalves RM. Trends and considerations in annulus fibrosus in vitro model design. Acta Biomater 2025; 195:42-51. [PMID: 39900271 DOI: 10.1016/j.actbio.2025.01.060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Revised: 01/09/2025] [Accepted: 01/30/2025] [Indexed: 02/05/2025]
Abstract
Annulus Fibrosus (AF) tissue integrity maintains intervertebral disc (IVD) structure, essential to spine mobility and shock absorption. However, this tissue, which confines nucleus pulposus (NP), has been poorly investigated, partially due to the lack of appropriate study models. This review provides a comprehensive analysis of AF in vitro models. By critically assessing the current AF in vitro models, this works thoroughly identifies key gaps in replicating the tissue's complex microenvironment. Finally, we outline the essential criteria for developing more accurate and reliable AF models, emphasizing the importance of biomaterial composition, architecture, and microenvironmental cues. By advancing in vitro models, we aim to deepen the understanding of AF failure mechanisms and support the development of novel therapeutic strategies for IVD herniation. Insights gained from this review may also have broader applications in regenerative medicine, particularly in the study and treatment of other connective tissue disorders. STATEMENT OF SIGNIFICANCE: This review evaluates the current in vitro models of the annulus fibrosus (AF), a key component of the intervertebral disc (IVD). By identifying gaps in these models, particularly in replicating tissue's complex microenvironment, we propose essential criteria for the development of more accurate AF models, to better understand the pathomechanisms and potentially aid the development of therapeutic approaches for spinal disorders. The findings also extend to broader studies of musculoskeletal tissue disorders in the context of regenerative medicine, appealing to a diverse biomedical research readership.
Collapse
Affiliation(s)
- A L Castro
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal; INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal; ICBAS - Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Rua Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal
| | - R M Gonçalves
- i3S - Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal; INEB - Instituto de Engenharia Biomédica, Universidade do Porto, Rua Alfredo Allen, 208, 4200-135, Porto, Portugal; ICBAS - Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Rua Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal.
| |
Collapse
|
2
|
Liang Z, Dai X, Li W, Chen W, Shi Q, Wei Y, Liang Q, Lin Y. Development of a spinopelvic complex finite element model for quantitative analysis of the biomechanical response of patients with degenerative spondylolisthesis. Med Biol Eng Comput 2025; 63:575-594. [PMID: 39425882 DOI: 10.1007/s11517-024-03218-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 10/03/2024] [Indexed: 10/21/2024]
Abstract
Research on degenerative spondylolisthesis (DS) has focused primarily on the biomechanical responses of pathological segments, with few studies involving muscle modelling in simulated analysis, leading to an emphasis on the back muscles in physical therapy, neglecting the ventral muscles. The purpose of this study was to quantitatively analyse the biomechanical response of the spinopelvic complex and surrounding muscle groups in DS patients using integrative modelling. The findings may aid in the development of more comprehensive rehabilitation strategies for DS patients. Two new finite element spinopelvic complex models with detailed muscles for normal spine and DS spine (L4 forwards slippage) modelling were established and validated at multiple levels. Then, the spinopelvic position parameters including peak stress of the lumbar isthmic-cortical bone, intervertebral discs, and facet joints; peak strain of the ligaments; peak force of the muscles; and percentage difference in the range of motion were analysed and compared under flexion-extension (F-E), lateral bending (LB), and axial rotation (AR) loading conditions between the two models. Compared with the normal spine model, the DS spine model exhibited greater stress and strain in adjacent biological tissues. Stress at the L4/5 disc and facet joints under AR and LB conditions was approximately 6.6 times greater in the DS spine model than in the normal model, the posterior longitudinal ligament peak strain in the normal model was 1/10 of that in the DS model, and more high-stress areas were found in the DS model, with stress notably transferring forwards. Additionally, compared with the normal spine model, the DS model exhibited greater muscle tensile forces in the lumbosacral muscle groups during F-E and LB motions. The psoas muscle in the DS model was subjected to 23.2% greater tensile force than that in the normal model. These findings indicated that L4 anterior slippage and changes in lumbosacral-pelvic alignment affect the biomechanical response of muscles. In summary, the present work demonstrated a certain level of accuracy and validity of our models as well as the differences between the models. Alterations in spondylolisthesis and the accompanying overall imbalance in the spinopelvic complex result in increased loading response levels of the functional spinal units in DS patients, creating a vicious cycle that exacerbates the imbalance in the lumbosacral region. Therefore, clinicians are encouraged to propose specific exercises for the ventral muscles, such as the psoas group, to address spinopelvic imbalance and halt the progression of DS.
Collapse
Affiliation(s)
- Ziyang Liang
- Department of Tuina and Spinal Orthopedics in Chinese Medicine, Shenzhen Traditional Chinese Medicine Hospital, Shenzhen, 518033, Guangdong, China
- The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, 518033, Guangdong, China
| | - Xiaowei Dai
- The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, 518033, Guangdong, China
- Graduate School, Guangzhou University of Chinese Medicine, Guangzhou, 510006, Guangdong, China
| | - Weisen Li
- Department of Tuina and Spinal Orthopedics in Chinese Medicine, Shenzhen Traditional Chinese Medicine Hospital, Shenzhen, 518033, Guangdong, China
- The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, 518033, Guangdong, China
| | - Weimei Chen
- Department of Tuina and Spinal Orthopedics in Chinese Medicine, Shenzhen Traditional Chinese Medicine Hospital, Shenzhen, 518033, Guangdong, China
- The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, 518033, Guangdong, China
| | - Qi Shi
- Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200032, China
- Key Laboratory of Theory and Therapy of Muscles and Bones, Ministry of Education, Shanghai, 200032, China
- Spine Institute, Shanghai Academy of Traditional Chinese Medicine, Shanghai, 200032, China
| | - Yizong Wei
- Beijing Guangming Orthopedics and Traumatology Hospital, Beijing, 102200, China
| | - Qianqian Liang
- Longhua Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200032, China
- Key Laboratory of Theory and Therapy of Muscles and Bones, Ministry of Education, Shanghai, 200032, China
- Spine Institute, Shanghai Academy of Traditional Chinese Medicine, Shanghai, 200032, China
| | - Yuanfang Lin
- Department of Tuina and Spinal Orthopedics in Chinese Medicine, Shenzhen Traditional Chinese Medicine Hospital, Shenzhen, 518033, Guangdong, China.
- The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine, Shenzhen, 518033, Guangdong, China.
| |
Collapse
|
3
|
Kriener K, Whiting H, Storr N, Homes R, Lala R, Gabrielyan R, Kuang J, Rubin B, Frails E, Sandstrom H, Futter C, Midwinter M. Applied use of biomechanical measurements from human tissues for the development of medical skills trainers: a scoping review. JBI Evid Synth 2023; 21:2309-2405. [PMID: 37732940 DOI: 10.11124/jbies-22-00363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/22/2023]
Abstract
OBJECTIVE The objective of this review was to identify quantitative biomechanical measurements of human tissues, the methods for obtaining these measurements, and the primary motivations for conducting biomechanical research. INTRODUCTION Medical skills trainers are a safe and useful tool for clinicians to use when learning or practicing medical procedures. The haptic fidelity of these devices is often poor, which may be because the synthetic materials chosen for these devices do not have the same mechanical properties as human tissues. This review investigates a heterogeneous body of literature to identify which biomechanical properties are available for human tissues, the methods for obtaining these values, and the primary motivations behind conducting biomechanical tests. INCLUSION CRITERIA Studies containing quantitative measurements of the biomechanical properties of human tissues were included. Studies that primarily focused on dynamic and fluid mechanical properties were excluded. Additionally, studies only containing animal, in silico , or synthetic materials were excluded from this review. METHODS This scoping review followed the JBI methodology for scoping reviews and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Sources of evidence were extracted from CINAHL (EBSCO), IEEE Xplore, MEDLINE (PubMed), Scopus, and engineering conference proceedings. The search was limited to the English language. Two independent reviewers screened titles and abstracts as well as full-text reviews. Any conflicts that arose during screening and full-text review were mediated by a third reviewer. Data extraction was conducted by 2 independent reviewers and discrepancies were mediated through discussion. The results are presented in tabular, figure, and narrative formats. RESULTS Data were extracted from a total of 186 full-text publications. All of the studies, except for 1, were experimental. Included studies came from 33 countries, with the majority coming from the United States. Ex vivo methods were the predominant approach for extracting human tissue samples, and the most commonly studied tissue type was musculoskeletal. In this study, nearly 200 unique biomechanical values were reported, and the most commonly reported value was Young's (elastic) modulus. The most common type of mechanical test performed was tensile testing, and the most common reason for testing human tissues was to characterize biomechanical properties. Although the number of published studies on biomechanical properties of human tissues has increased over the past 20 years, there are many gaps in the literature. Of the 186 included studies, only 7 used human tissues for the design or validation of medical skills training devices. Furthermore, in studies where biomechanical values for human tissues have been obtained, a lack of standardization in engineering assumptions, methodologies, and tissue preparation may implicate the usefulness of these values. CONCLUSIONS This review is the first of its kind to give a broad overview of the biomechanics of human tissues in the published literature. With respect to high-fidelity haptics, there is a large gap in the published literature. Even in instances where biomechanical values are available, comparing or using these values is difficult. This is likely due to the lack of standardization in engineering assumptions, testing methodology, and reporting of the results. It is recommended that journals and experts in engineering fields conduct further research to investigate the feasibility of implementing reporting standards. REVIEW REGISTRATION Open Science Framework https://osf.io/fgb34.
Collapse
Affiliation(s)
- Kyleigh Kriener
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Harrison Whiting
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- School of Clinical Medicine, Royal Brisbane Clinical Unit, The University of Queensland, Brisbane, QLD, Australia
| | - Nicholas Storr
- Gold Coast University Hospital, Southport, QLD Australia
| | - Ryan Homes
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Raushan Lala
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| | - Robert Gabrielyan
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Jasmine Kuang
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Bryn Rubin
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
- Ochsner Clinical School, Jefferson, LA, United States
| | - Edward Frails
- Department of Chemical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - Hannah Sandstrom
- Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, United States
| | - Christopher Futter
- Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia
- Anaesthesia and Intensive Care Program, Herston Biofabrication institute, Brisbane, QLD, Australia
| | - Mark Midwinter
- School of Biomedical Sciences, The University of Queensland, Brisbane, QLD, Australia
| |
Collapse
|
4
|
Li X, Liu Y, Li L, Huo R, Ghezelbash F, Ma Z, Bao G, Liu S, Yang Z, Weber MH, Li-Jessen NYK, Haglund L, Li J. Tissue-mimetic hybrid bioadhesives for intervertebral disc repair. MATERIALS HORIZONS 2023; 10:1705-1718. [PMID: 36857679 DOI: 10.1039/d2mh01242a] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Intervertebral disc (IVD) degeneration and herniation often necessitate surgical interventions including a discectomy with or without a nucleotomy, which results in a loss of the normal nucleus pulposus (NP) and a defect in the annulus fibrosus (AF). Due to the limited regenerative capacity of the IVD tissue, the annular tear may remain a persistent defect and result in recurrent herniation post-surgery. Bioadhesives are promising alternatives but show limited adhesion performance, low regenerative capacity, and inability to prevent re-herniation. Here, we report hybrid bioadhesives that combine an injectable glue and a tough sealant to simultaneously repair and regenerate IVD post-nucleotomy. The glue fills the NP cavity while the sealant seals the AF defect. Strong adhesion occurs with the IVD tissues and survives extreme disc loading. Furthermore, the glue can match native NP mechanically, and support the viability and matrix deposition of encapsulated cells, serving as a suitable cell delivery vehicle to promote NP regeneration. Besides, biomechanical tests with bovine IVD motion segments demonstrate the capacity of the hybrid bioadhesives to restore the biomechanics of bovine discs under cyclic loading and to prevent permanent herniation under extreme loading. This work highlights the synergy of bioadhesive and tissue-engineering approaches. Future works are expected to further improve the tissue specificity of bioadhesives and prove their efficacy for tissue repair and regeneration.
Collapse
Affiliation(s)
- Xuan Li
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
| | - Yin Liu
- Department of Biomedical Engineering, McGill University, 3775 rue University, Montreal, Quebec H3A 2B4, Canada
| | - Li Li
- Department of Surgery, McGill University, 1650 Cedar Avenue, Room C10.148.2, Montreal, QC, H3G 1A4, Canada.
| | - Ran Huo
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
| | - Farshid Ghezelbash
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
- Department of Mechanical Engineering, Polytechnique Montreal, Montreal, Quebec H3C 3A7, Canada
| | - Zhenwei Ma
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
| | - Guangyu Bao
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
| | - Shiyu Liu
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
| | - Zhen Yang
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
| | - Michael H Weber
- Department of Surgery, McGill University, 1650 Cedar Avenue, Room C10.148.2, Montreal, QC, H3G 1A4, Canada.
| | - Nicole Y K Li-Jessen
- Department of Biomedical Engineering, McGill University, 3775 rue University, Montreal, Quebec H3A 2B4, Canada
- School of Communication Sciences and Disorders, McGill University, Montreal, Quebec H3A 1G1, Canada
- Department of Otolaryngology-Head & Neck Surgery, McGill University, Montreal, Quebec H3A 1G1, Canada
| | - Lisbet Haglund
- Department of Surgery, McGill University, 1650 Cedar Avenue, Room C10.148.2, Montreal, QC, H3G 1A4, Canada.
| | - Jianyu Li
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke St W, Montreal, QC H3A 0C3, Canada.
- Department of Biomedical Engineering, McGill University, 3775 rue University, Montreal, Quebec H3A 2B4, Canada
- Department of Surgery, McGill University, 1650 Cedar Avenue, Room C10.148.2, Montreal, QC, H3G 1A4, Canada.
| |
Collapse
|
5
|
Azril, Huang KY, Hobley J, Rouhani M, Liu WL, Jeng YR. Correlation of the degenerative stage of a disc with magnetic resonance imaging, chemical content, and biomechanical properties of the nucleus pulposus. J Biomed Mater Res A 2022; 111:1054-1066. [PMID: 36585891 DOI: 10.1002/jbm.a.37490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 12/05/2022] [Accepted: 12/14/2022] [Indexed: 01/01/2023]
Abstract
Intervertebral disc degeneration (IDD) is closely related to changes in the intervertebral disc (IVD) composition and the resulting viscoelastic properties. IDD is a severe condition because it decreases the disc's ability to resist mechanical loads. Our research aims to understand IDD at the cellular level, specifically the changes in the viscoelastic properties of the nucleus pulposus (NP), which are poorly understood. This study employed a system integrating nanoindentation with Raman spectrometry to correlate biomechanics with subtle changes in the biochemical makeup of the NP. The characterization was, in turn, correlated with the degenerative severity of IVD as assessed using magnetic resonance imaging (MRI) of different patients with spinal stenosis, degenerative spondylolisthesis, and degenerative scoliosis. It is shown that there is an increase in the crosslinking ratio in collagen, a reduction in proteoglycan, and a build-up of minerals upon the rise in the severity level of the disc damage in the NP. Assessment of mechanical characteristics reveals that the increasing disc degeneration makes the NP lose its elasticity, becoming more viscous. This shows that the tissue undergoes abnormalities in weight-bearing ability, which contributes to spinal instability. The correlation of the individual discs shows that grades III and IV have similarities in the changes of Amide I and III toward the storage modulus. In contrast, grades IV and V correlate with mineralization toward the storage modulus. Reduction of proteoglycan has the highest impact on the changes of the storage modulus in all grades of IDD. Connecting compositional alterations to IVD micromechanics at various degrees of degeneration expands our understanding of tissue behavior and provides critical insight into clinical diagnostics, treatment, and tissue engineering.
Collapse
Affiliation(s)
- Azril
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan
| | - Kuo-Yuan Huang
- Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, Tainan City, Taiwan
| | - Jonathan Hobley
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan
| | - Mehdi Rouhani
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan
| | - Wen-Lung Liu
- Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, Tainan City, Taiwan
| | - Yeau-Ren Jeng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan.,Academy of Innovative Semiconductor and Sustainable Manufacturing, National Cheng Kung University, Tainan City, Taiwan.,Medical Device Innovation Center, National Cheng Kung University, Tainan City, Taiwan
| |
Collapse
|
6
|
Yu Z, Thakolkaran P, Shea K, Stanković T. Artificial neural network supported design of a lattice-based artificial spinal disc for restoring patient-specific anisotropic behaviors. Comput Biol Med 2022. [DOI: 10.1016/j.compbiomed.2022.106475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
7
|
Costi JJ, Ledet EH, O'Connell GD. Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence. JOR Spine 2021; 4:e1138. [PMID: 33778410 PMCID: PMC7984003 DOI: 10.1002/jsp2.1138] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 12/04/2020] [Accepted: 12/07/2020] [Indexed: 12/14/2022] Open
Abstract
Biomechanical testing methodologies for the spine have developed over the past 50 years. During that time, there have been several paradigm shifts with respect to techniques. These techniques evolved by incorporating state-of-the-art engineering principles, in vivo measurements, anatomical structure-function relationships, and the scientific method. Multiple parametric studies have focused on the effects that the experimental technique has on outcomes. As a result, testing methodologies have evolved, but there are no standard testing protocols, which makes the comparison of findings between experiments difficult and conclusions about in vivo performance challenging. In 2019, the international spine research community was surveyed to determine the consensus on spine biomechanical testing and if the consensus opinion was consistent with the scientific evidence. More than 80 responses to the survey were received. The findings of this survey confirmed that while some methods have been commonly adopted, not all are consistent with the scientific evidence. This review summarizes the scientific literature, the current consensus, and the authors' recommendations on best practices based on the compendium of available evidence.
Collapse
Affiliation(s)
- John J. Costi
- Biomechanics and Implants Research Group, Medical Device Research Institute, College of Science and EngineeringFlinders UniversityAdelaideAustralia
| | - Eric H. Ledet
- Department of Biomedical EngineeringRensselaer Polytechnic InstituteTroyNew YorkUSA
- Research and Development ServiceStratton VA Medical CenterAlbanyNew YorkUSA
| | - Grace D. O'Connell
- Department of Mechanical EngineeringUniversity of California‐BerkeleyBerkeleyCaliforniaUSA
- Department of Orthopaedic SurgeryUniversity of California‐San FranciscoSan FranciscoCaliforniaUSA
| |
Collapse
|
8
|
Wang C, Shi Z. [Research progress in creep characteristics of lumbar intervertebral disc]. ZHONGGUO XIU FU CHONG JIAN WAI KE ZA ZHI = ZHONGGUO XIUFU CHONGJIAN WAIKE ZAZHI = CHINESE JOURNAL OF REPARATIVE AND RECONSTRUCTIVE SURGERY 2020; 34:1624-1629. [PMID: 33319547 DOI: 10.7507/1002-1892.202002167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective To summarize the research progress in creep characteristics of lumbar intervertebral disc. Methods The relevant literature at home and abroad was systematically searched. Then, the concept and structural basis of lumbar disc creep, the description of creep characteristics, and the latest progress of its influencing factors were summarized and analyzed. Results The intervertebral disc is viscoelastic. After loading, the deformation increases with time. However, the degree of increase is not linear with time. That is creep, which plays an important role in buffering the load generated by human activities and absorbing energy in order to maintain stable movement of the spine. Both experimental and simulation studies can well describe the creep behavior of intervertebral disc. Various models including standard linear solid model and corresponding constitutive equations can quantify and compare the creep characteristics, which can be obviously changed by the degeneration of intervertebral disc and the mode of loading stress. Conclusion Creep is an important mechanical properties of intervertebral discs, and an in-depth understanding of the creep characteristics of lumbar intervertebral discs is of great guiding significance for the intervention and treatment of low back pain.
Collapse
Affiliation(s)
- Chao Wang
- Department of Spine Surgery, Changhai Hospital Affiliated to Naval Medical University, Shanghai, 200433, P.R.China
| | - Zhicai Shi
- Department of Spine Surgery, Changhai Hospital Affiliated to Naval Medical University, Shanghai, 200433, P.R.China
| |
Collapse
|
9
|
Ashinsky BG, Gullbrand SE, Wang C, Bonnevie ED, Han L, Mauck RL, Smith HE. Degeneration alters structure-function relationships at multiple length-scales and across interfaces in human intervertebral discs. J Anat 2020; 238:986-998. [PMID: 33205444 DOI: 10.1111/joa.13349] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 09/19/2020] [Accepted: 10/08/2020] [Indexed: 12/19/2022] Open
Abstract
Intervertebral disc (IVD) degeneration and associated back pain place a significant burden on the population. IVD degeneration is a progressive cascade of cellular, compositional, and structural changes, which results in a loss of disc height, disorganization of extracellular matrix architecture, tears in the annulus fibrosus which may involve herniation of the nucleus pulposus, and remodeling of the bony and cartilaginous endplates (CEP). These changes to the IVD often occur concomitantly, across the entire motion segment from the disc subcomponents to the CEP and vertebral bone, making it difficult to determine the causal initiating factor of degeneration. Furthermore, assessments of the subcomponents of the IVD have been largely qualitative, with most studies focusing on a single attribute, rather than multiple adjacent IVD substructures. The objective of this study was to perform a multiscale and multimodal analysis of human lumbar motion segments across various length scales and degrees of degeneration. We performed multiple assays on every sample and identified several correlations between structural and functional measurements of disc subcomponents. Our results demonstrate that with increasing Pfirrmann grade there is a reduction in disc height and nucleus pulposus T2 relaxation time, in addition to alterations in motion segment macromechanical function, disc matrix composition and cellular morphology. At the cartilage endplate-vertebral bone interface, substantial remodeling was observed coinciding with alterations in micromechanical properties. Finally, we report significant relationships between vertebral bone and nucleus pulposus metrics, as well as between micromechanical properties of the endplate and whole motion segment biomechanical parameters, indicating the importance of studying IVD degeneration as a whole organ.
Collapse
Affiliation(s)
- Beth G Ashinsky
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.,Drexel University School of Biomedical Engineering, Science and Health Systems, Philadelphia, PA, USA.,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA
| | - Sarah E Gullbrand
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA
| | - Chao Wang
- Drexel University School of Biomedical Engineering, Science and Health Systems, Philadelphia, PA, USA
| | - Edward D Bonnevie
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA
| | - Lin Han
- Drexel University School of Biomedical Engineering, Science and Health Systems, Philadelphia, PA, USA
| | - Robert L Mauck
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA
| | - Harvey E Smith
- McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.,Translational Musculoskeletal Research Center, Corporal Michael J. Crescenz VA Medical Center, Philadelphia, PA, USA
| |
Collapse
|
10
|
Nonlinear stress-dependent recovery behavior of the intervertebral disc. J Mech Behav Biomed Mater 2020; 110:103881. [PMID: 32957189 DOI: 10.1016/j.jmbbm.2020.103881] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2019] [Revised: 04/22/2020] [Accepted: 05/23/2020] [Indexed: 12/17/2022]
Abstract
The intervertebral disc exhibits complex mechanics due to its heterogeneous structure, inherent viscoelasticity, and interstitial fluid-matrix interactions. Sufficient fluid flow into the disc during low loading periods is important for maintaining mechanics and nutrient transport. However, there is a lack of knowledge on the effect of loading magnitude on time-dependent recovery behavior and the relative contribution of multiple recovery mechanisms during recovery. In most studies that have evaluated disc recovery behavior, a single load condition has been considered, making it difficult to compare findings across studies. Hence, the objective of this study was to quantify unloaded disc recovery behavior after compressive creep loading under a wide range of physiologically relevant stresses (0.2-2 MPa). First, the repeatability of disc recovery behavior was assessed. Once repeatable recovery behavior was confirmed, each motion segment was subject to three cycles of creep-recovery loading, where each cycle consisted of a 24-h creep at a pre-assigned load (100, 200, 300, 600, 900, or 1200 N), followed by an 18-h recovery period at a nominal load (10 N). Results showed that disc recovery behavior was strongly influenced by the magnitude of loading. The magnitude of instantaneous and time-dependent recovery deformations increased nonlinearly with an increase in compressive stress during creep. In conclusion, this study highlights that elastic deformation, intrinsic viscoelasticity, and poroelasticity all have substantial contributions to disc height recovery during low loading periods. However, their relative contributions to disc height recovery largely depend on the magnitude of loading. While loading history does not influence the contribution of the short-term recovery, the contribution of long-term recovery is highly sensitive to loading magnitude.
Collapse
|
11
|
Duclos SE, Michalek AJ. Mapping of Intervertebral Disk Annulus Fibrosus Compressive Properties Is Sensitive to Specimen Boundary Conditions. J Biomech Eng 2019; 141:2723102. [DOI: 10.1115/1.4042600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2018] [Indexed: 11/08/2022]
Abstract
Predicting the mechanical behavior of the intervertebral disk (IVD) in health and in disease requires accurate spatial mapping of its compressive mechanical properties. Previous studies confirmed that residual strains in the annulus fibrosus (AF) of the IVD, which result from nonuniform extracellular matrix deposition in response to in vivo loads, vary by anatomical regions (anterior, posterior, and lateral) and zones (inner, middle, and outer). We hypothesized that as the AF is composed of a nonlinear, anisotropic, viscoelastic material, the state of residual strain in the transverse plane would influence the apparent values of axial compressive properties. To test this hypothesis, axial creep indentation tests were performed, using a 1.6 mm spherical probe, at nine different anatomical locations on bovine caudal AFs in both the intact (residual strain present) and strain relieved states. The results showed a shift toward increased spatial homogeneity in all measured parameters, particularly instantaneous strain. This shift was not observed in control AFs, which were tested twice in the intact state. Our results confirm that time-dependent axial compressive properties of the AF are sensitive to the state of residual strain in the transverse plane, to a degree that is likely to affect whole disk behavior.
Collapse
Affiliation(s)
- Sarah E. Duclos
- Department of Mechanical & Aeronautical Engineering, Clarkson University, P.O. Box 5725, Potsdam, NY 13699
| | - Arthur J. Michalek
- Department of Mechanical & Aeronautical Engineering, Clarkson University, P.O. Box 5725, Potsdam, NY 13699 e-mail:
| |
Collapse
|
12
|
Nabavizadeh A, Kinnick RR, Bayat M, Amador C, Urban MW, Alizad A, Fatemi M. Automated Compression Device for Viscoelasticity Imaging. IEEE Trans Biomed Eng 2017; 64:1535-1546. [PMID: 28113299 PMCID: PMC5485831 DOI: 10.1109/tbme.2016.2612541] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Noninvasive measurement of tissue viscoelastic properties is gaining more attention for screening and diagnostic purposes. Recently, measuring dynamic response of tissue under a constant force has been studied for estimation of tissue viscoelastic properties in terms of retardation times. The essential part of such a test is an instrument that is capable of creating a controlled axial force and is suitable for clinical applications. Such a device should be lightweight, portable, and easy to use for patient studies to capture tissue dynamics under external stress. In this paper, we present the design of an automated compression device for studying the creep response of materials with tissue-like behaviors. The device can be used to apply a ramp-and-hold force excitation for a predetermined duration of time and it houses an ultrasound probe for monitoring the creep response of the underlying tissue. To validate the performance of the device, several creep tests were performed on tissue-mimicking phantoms, and the results were compared against those from a commercial mechanical testing instrument. Using a second-order Kelvin-Voigt model and surface measurement of the forces and displacements, retardation times T1 and T2 were estimated from each test. These tests showed strong agreement between our automated compression device and the commercial mechanical testing system, with an average relative error of 2.9% and 12.4%, for T1 and T2, respectively. Also, we present the application of compression device to measure local retardation times for four different phantoms with different size and stiffness.
Collapse
|
13
|
Fernandez C, Marionneaux A, Gill S, Mercuri J. Biomimetic nucleus pulposus scaffold created from bovine caudal intervertebral disc tissue utilizing an optimal decellularization procedure. J Biomed Mater Res A 2016; 104:3093-3106. [PMID: 27507100 PMCID: PMC5832047 DOI: 10.1002/jbm.a.35858] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Revised: 07/14/2016] [Accepted: 08/05/2016] [Indexed: 11/07/2022]
Abstract
Intervertebral disc (IVD) degeneration (IDD) and herniation (IDH) can result in low back pain and impart significant socioeconomic burden. These pathologies involve detrimental alteration to the nucleus pulposus (NP) either via biochemical degradation or extrusion from the IVD, respectively. Thus, engineering living NP tissue utilizing biomaterial scaffolds that recapitulate native NP microarchitecture, biochemistry, mechanical properties, and which support cell viability represents an approach to aiding patients with IDD and IDH. To date, an ideal biomaterial to support NP regeneration has yet to be developed; however, one promising approach to generating biomimetic materials is to employ the decellularization (decell) of xenogeneic NP tissue to remove host DNA while maintaining critical native extracellular matrix (ECM) components. Herein, 13 different procedures were evaluated in an attempt to decell bovine caudal IVD NP tissue. An optimal method was identified which was confirmed to effectively remove bovine DNA, while maintaining physiologically relevant amounts of glycosaminoglycan (GAG) and type II collagen. Unconfined static and dynamic compressive mechanical properties of scaffolds approached values reported for human NP and viability of human amniotic stem cells (hAMSCs) was maintained on noncrosslinked and EDC/NHS treated scaffolds for up to 14 days in culture. Taken together, NP tissue obtained from bovine caudal IVDs can be successfully decelled in order to generate a biomimetic scaffold for NP tissue regeneration. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 3093-3106, 2016.
Collapse
Affiliation(s)
- Christopher Fernandez
- Department of Bioengineering, The Laboratory of Orthopaedic Tissue Regeneration & Orthobiologics, Clemson University, Clemson, South Carolina
| | - Alan Marionneaux
- Department of Bioengineering, The Laboratory of Orthopaedic Tissue Regeneration & Orthobiologics, Clemson University, Clemson, South Carolina
| | - Sanjitpal Gill
- Department of Bioengineering, The Laboratory of Orthopaedic Tissue Regeneration & Orthobiologics, Clemson University, Clemson, South Carolina
- Department of Orthopaedic Surgery, Spartanburg Regional Healthcare System, Greer, South Carolina
| | - Jeremy Mercuri
- Department of Bioengineering, The Laboratory of Orthopaedic Tissue Regeneration & Orthobiologics, Clemson University, Clemson, South Carolina.
| |
Collapse
|
14
|
Rouch P, Skalli W. Biomécanique du disque lombaire normal et pathologique. BULLETIN DE L'ACADÉMIE NATIONALE DE MÉDECINE 2015. [DOI: 10.1016/s0001-4079(19)30821-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
15
|
Liu H, Guan Y, Wei D, Gao C, Yang H, Yang L. Reinforcement of injectable calcium phosphate cement by gelatinized starches. J Biomed Mater Res B Appl Biomater 2015; 104:615-25. [PMID: 25953516 DOI: 10.1002/jbm.b.33434] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2014] [Revised: 03/23/2015] [Accepted: 04/14/2015] [Indexed: 12/11/2022]
Affiliation(s)
- Huiling Liu
- Department of Orthopaedics; Orthopaedic Institute, The First Affiliated Hospital, Soochow University; Suzhou Jiangsu 215006 People's Republic of China
| | - Ying Guan
- College of Chemistry, Chemical Engineering and Materials Science, Soochow University; Suzhou Jiangsu 215123 People's Republic of China
| | - Donglei Wei
- Department of Orthopaedics; Orthopaedic Institute, The First Affiliated Hospital, Soochow University; Suzhou Jiangsu 215006 People's Republic of China
| | - Chunxia Gao
- Department of Orthopaedics; Orthopaedic Institute, The First Affiliated Hospital, Soochow University; Suzhou Jiangsu 215006 People's Republic of China
| | - Huilin Yang
- Department of Orthopaedics; Orthopaedic Institute, The First Affiliated Hospital, Soochow University; Suzhou Jiangsu 215006 People's Republic of China
| | - Lei Yang
- Department of Orthopaedics; Orthopaedic Institute, The First Affiliated Hospital, Soochow University; Suzhou Jiangsu 215006 People's Republic of China
- The State Key Laboratory of Nonlinear Mechanics, Institute of Mechanics, Chinese Academy of Sciences; Beijing 100190 People's Republic of China
| |
Collapse
|
16
|
Ma XL. A new pathological classification of lumbar disc protrusion and its clinical significance. Orthop Surg 2015; 7:1-12. [PMID: 25708029 DOI: 10.1111/os.12152] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2014] [Accepted: 11/26/2014] [Indexed: 11/30/2022] Open
Abstract
Lumbar disc protrusion is common. Its clinical manifestations and treatments are closely related to the pathological changes; however, the pathological classification of lumbar disc protrusion is controversial. This article introduces a new pathological classification comprising four types of lumbar disc protrusion according to intraoperative findings. The damage-herniation type is probably caused by injury and is characterized by soft herniation, the capsule can easily be cut and the broken disc tissue blocks overflow or is easily removed. The broken disc substances should be completely removed; satisfactory results can be achieved by minimally invasive endoscopic surgery. The degeneration-protrusion type is characterized by hard and tough protrusions and the pathological process by degeneration and proliferative reaction. The nerve should be decompressed and relaxed with minimally invasive removal of the posterior wall; the bulged or protruded disc often need not be excised. The posterior vertebral osteochondrosis with disc protrusion type is characterized by deformity of the posterior vertebral body, osteochondral nodules and intervertebral disc protrusion. The herniated and fragmented disc tissue should be removed with partially protruding osteochondral nodules. Intervertebral disc cyst is of uncertain pathogenesis and is characterized by a cyst that communicates with the disc. Resection of the cyst under microscopic or endoscopic control can achieve good results; and whether the affected disc needs to be simultaneously resected is controversial. The new pathological classification proposed here is will aid better understanding of pathological changes and pathogenesis of lumbar disc protrusion and provides a reference for diagnosis and treatment.
Collapse
Affiliation(s)
- Xin-long Ma
- Department of Spine Surgery, Tianjin Hospital, Tianjin, China
| |
Collapse
|
17
|
Zirbel SA, Stolworthy DK, Howell LL, Bowden AE. A standardized representation of spinal quality of motion. Proc Inst Mech Eng H 2014; 228:1168-75. [PMID: 25500861 DOI: 10.1177/0954411914559079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The experimentally determined torque-rotation curve of the lumbar spine is mathematically described with a proposed dual-inflection point Boltzmann equation. The result is a method for describing functional spinal unit motion data. The benefit of the model is that each of the coefficients has a specific meaning in relation to the torque-rotation curve: the points A and B identify the respective minimum and maximum rotations of the functional spinal unit, m1 and m2 indicate the inflection points of the curve where the stiffness changes markedly, and α1 and α2 are associated with the rates of change of the curve at m1 and m2, respectively. The dual-inflection point Boltzmann captures the full quality of motion of the spinal segment and can also be used to derive relevant parameters such as range of motion, midrange stiffness, and hysteresis.
Collapse
Affiliation(s)
- Shannon A Zirbel
- Mechanical Engineering Department, Brigham Young University, Provo, UT, USA
| | - Dean K Stolworthy
- Mechanical Engineering Department, Brigham Young University, Provo, UT, USA
| | - Larry L Howell
- Mechanical Engineering Department, Brigham Young University, Provo, UT, USA
| | - Anton E Bowden
- Mechanical Engineering Department, Brigham Young University, Provo, UT, USA
| |
Collapse
|
18
|
Castro-Mateos I, Pozo JM, Eltes PE, Rio LD, Lazary A, Frangi AF. 3D segmentation of annulus fibrosus and nucleus pulposus from T2-weighted magnetic resonance images. Phys Med Biol 2014; 59:7847-64. [DOI: 10.1088/0031-9155/59/24/7847] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
19
|
Non-invasive biomechanical characterization of intervertebral discs by shear wave ultrasound elastography: a feasibility study. Eur Radiol 2014; 24:3210-6. [PMID: 25120207 DOI: 10.1007/s00330-014-3382-8] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2014] [Revised: 07/08/2014] [Accepted: 07/31/2014] [Indexed: 12/16/2022]
Abstract
OBJECTIVES Although magnetic resonance is widely spread to assess qualitatively disc morphology, a simple method to determine reliably intervertebral disc status is still lacking. Shear wave elastography is a novel technique that allows quantitative evaluation of soft-tissues' mechanical properties. The aim of this study was to assess preliminary the feasibility and reliability of mechanical characterization of cervical intervertebral discs by elastography and to provide first reference values for asymptomatic subjects. METHODS Elastographic measurements were performed to determine shear wave speed (SWS) in C6-C7 or C7-T1 disc of 47 subjects; repeatability and inter-operator reproducibility were assessed. RESULTS Global average shear wave speed (SWS) was 3.0 ± 0.4 m/s; measurement repeatability and inter-user reproducibility were 7 and 10%, respectively. SWS was correlated with both subject's age (p = 1.3 × 10(-5)) and body mass index (p = 0.008). CONCLUSIONS Shear wave elastography in intervertebral discs proved reliable and allowed stratification of subjects according to age and BMI. Applications could be relevant, for instance, in early detection of disc degeneration or in follow-up after trauma; these results open the way to larger cohort studies to define the place of this technique in routine intervertebral disc assessment. KEY POINTS A simple method to obtain objectively intervertebral disc status is still lacking. Shear wave elastography was applied in vivo to assess intervertebral discs. Elastography showed promising results in biomechanical disc evaluation. Elastography could be relevant in clinical routine for intervertebral disc assessment.
Collapse
|
20
|
Finite element analyses of human vertebral bodies embedded in polymethylmethalcrylate or loaded via the hyperelastic intervertebral disc models provide equivalent predictions of experimental strength. J Biomech 2014; 47:2512-6. [DOI: 10.1016/j.jbiomech.2014.04.015] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2014] [Revised: 04/07/2014] [Accepted: 04/07/2014] [Indexed: 11/24/2022]
|
21
|
Vergari C, Rouch P, Dubois G, Bonneau D, Dubousset J, Tanter M, Gennisson JL, Skalli W. Intervertebral disc characterization by shear wave elastography: An in vitro preliminary study. Proc Inst Mech Eng H 2014; 228:607-615. [DOI: 10.1177/0954411914540279] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Patient-specific numerical simulation of the spine is a useful tool both in clinic and research. While geometrical personalization of the spine is no more an issue, thanks to recent technological advances, non-invasive personalization of soft tissue’s mechanical properties remains a challenge. Ultrasound elastography is a relatively recent measurement technique allowing the evaluation of soft tissue’s elastic modulus through the measurement of shear wave speed. The aim of this study was to determine the feasibility of elastographic measurements in intervertebral disc. An in vitro approach was chosen to test the hypothesis that shear wave speed can be used to evaluate intervertebral disc mechanical properties and to assess measurement repeatability. In total, 11 oxtail intervertebral discs were tested in compression to determine their stiffness and apparent elastic modulus at rest and at 400 N. Elastographic measurements were performed in these two conditions and compared to these mechanical parameters. The protocol was repeated six times to determine elastographic measurement repeatability. Average shear wave speed over all samples was 5.3 ± 1.0 m/s, with a repeatability of 7% at rest and 4.6% at 400 N; stiffness and apparent elastic modulus were 266.3 ± 70.5 N/mm and 5.4 ± 1.1 MPa at rest, respectively, while at 400 N they were 781.0 ± 153.8 N/mm and 13.2 ± 2.4 MPa, respectively. Correlations were found between elastographic measurements and intervertebral disc mechanical properties; these preliminary results are promising for further in vivo application.
Collapse
Affiliation(s)
| | | | | | | | | | - Mickael Tanter
- Institut Langevin, Ondes et Images, ESPCI ParisTech, CNRS UMR7587, INSERM U979, Paris, France
| | - Jean-Luc Gennisson
- Institut Langevin, Ondes et Images, ESPCI ParisTech, CNRS UMR7587, INSERM U979, Paris, France
| | - Wafa Skalli
- Arts et Métiers ParisTech, LBM, Paris, France
| |
Collapse
|
22
|
Landi A. Elastic resistance of the spine: Why does motion preservation surgery almost fail? World J Clin Cases 2013; 1:134-139. [PMID: 24303484 PMCID: PMC3845953 DOI: 10.12998/wjcc.v1.i4.134] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/22/2013] [Revised: 04/11/2013] [Accepted: 06/10/2013] [Indexed: 02/05/2023] Open
Abstract
Single metamere motility should not be interpreted merely as a movement on the 3 planes but also, and above all, as elastic resistance to dynamic stress on these 3 planes. In the light of this consideration, the aim of motion preservation is to neutralize excessive movements while preserving the physiological biomechanical properties of the metamere involved to interrupt the progression of degenerative processes and to prevent adjacent segment disease. Despite the fact that a myriad of devices have been developed with the purpose of achieving dynamic neutralization of the spine, there are now some doubts regarding the true efficacy of these devices.
Collapse
|
23
|
Lazennec JY, Aaron A, Brusson A, Rakover JP, Rousseau MA. The LP-ESP(®) lumbar disc prosthesis with 6 degrees of freedom: development and 7 years of clinical experience. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2013; 23:131-43. [PMID: 23412443 PMCID: PMC3567327 DOI: 10.1007/s00590-012-1166-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2012] [Accepted: 12/29/2012] [Indexed: 12/24/2022]
Abstract
The viscoelastic lumbar disk prosthesis-elastic spine pad (LP-ESP(®)) is an innovative one-piece deformable but cohesive interbody spacer providing 6 full degrees of freedom about the 3 axes, including shock absorption. A 20-year research program has demonstrated that this concept provides mechanical properties very close to those of a natural disk. Improvements in technology have made it possible to solve the problem of the bond between the elastic component and the titanium endplates and to obtain an excellent biostability. The prosthesis geometry allows limited rotation and translation with resistance to motion (elastic return property) aimed at avoiding overload of the posterior facets. The rotation center can vary freely during motion. It thus differs substantially from current prostheses, which are 2- or 3-piece devices involving 1 or 2 bearing surfaces and providing 3 or 5 degrees of freedom. This design and the adhesion-molding technology differentiate the LP-ESP prosthesis from other mono-elastomeric prostheses, for which the constraints of shearing during rotations or movement are absorbed at the endplate interface. Seven years after the first implantation, we can document in a solid and detailed fashion the course of clinical outcomes and the radiological postural and kinematic behavior of this prosthesis.
Collapse
Affiliation(s)
- Jean-Yves Lazennec
- Department of Orthopedic and Trauma Surgery, La Pitié-Salpétrière Hospital, 47-83 boulevard de l'Hôpital, 75013, Paris, France.
| | | | | | | | | |
Collapse
|
24
|
Sensitivity of multi-parametric MRI to the compressive state of the isolated intervertebral discs. Magn Reson Imaging 2013; 31:36-43. [DOI: 10.1016/j.mri.2012.06.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2011] [Accepted: 06/21/2012] [Indexed: 11/22/2022]
|
25
|
Recuerda M, Périé D, Gilbert G, Beaudoin G. Assessment of mechanical properties of isolated bovine intervertebral discs from multi-parametric magnetic resonance imaging. BMC Musculoskelet Disord 2012; 13:195. [PMID: 23061966 PMCID: PMC3565974 DOI: 10.1186/1471-2474-13-195] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2012] [Accepted: 10/08/2012] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The treatment planning of spine pathologies requires information on the rigidity and permeability of the intervertebral discs (IVDs). Magnetic resonance imaging (MRI) offers great potential as a sensitive and non-invasive technique for describing the mechanical properties of IVDs. However, the literature reported small correlation coefficients between mechanical properties and MRI parameters. Our hypothesis is that the compressive modulus and the permeability of the IVD can be predicted by a linear combination of MRI parameters. METHODS Sixty IVDs were harvested from bovine tails, and randomly separated in four groups (in-situ, digested-6h, digested-18h, digested-24h). Multi-parametric MRI acquisitions were used to quantify the relaxation times T1 and T2, the magnetization transfer ratio MTR, the apparent diffusion coefficient ADC and the fractional anisotropy FA. Unconfined compression, confined compression and direct permeability measurements were performed to quantify the compressive moduli and the hydraulic permeabilities. Differences between groups were evaluated from a one way ANOVA. Multi linear regressions were performed between dependent mechanical properties and independent MRI parameters to verify our hypothesis. A principal component analysis was used to convert the set of possibly correlated variables into a set of linearly uncorrelated variables. Agglomerative Hierarchical Clustering was performed on the 3 principal components. RESULTS Multilinear regressions showed that 45 to 80% of the Young's modulus E, the aggregate modulus in absence of deformation HA0, the radial permeability kr and the axial permeability in absence of deformation k0 can be explained by the MRI parameters within both the nucleus pulposus and the annulus pulposus. The principal component analysis reduced our variables to two principal components with a cumulative variability of 52-65%, which increased to 70-82% when considering the third principal component. The dendograms showed a natural division into four clusters for the nucleus pulposus and into three or four clusters for the annulus fibrosus. CONCLUSIONS The compressive moduli and the permeabilities of isolated IVDs can be assessed mostly by MT and diffusion sequences. However, the relationships have to be improved with the inclusion of MRI parameters more sensitive to IVD degeneration. Before the use of this technique to quantify the mechanical properties of IVDs in vivo on patients suffering from various diseases, the relationships have to be defined for each degeneration state of the tissue that mimics the pathology. Our MRI protocol associated to principal component analysis and agglomerative hierarchical clustering are promising tools to classify the degenerated intervertebral discs and further find biomarkers and predictive factors of the evolution of the pathologies.
Collapse
Affiliation(s)
- Maximilien Recuerda
- Mechanical Engineering Department, Ecole Polytechnique de Montréal, Montréal, QC, Canada
| | | | | | | |
Collapse
|