1
|
Wang S, Liu W, Yang C, Zhang X, Lyu C. Sulfonated polyetheretherketone enriched with MXene V 2C promotes bone formation via WNT/β-catenin signaling in bone marrow mesenchymal stem cells. Med Eng Phys 2025; 141:104361. [PMID: 40514103 DOI: 10.1016/j.medengphy.2025.104361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2025] [Revised: 04/30/2025] [Accepted: 05/12/2025] [Indexed: 06/16/2025]
Abstract
Prosthetic loosening represents a catastrophic postoperative complication in artificial joint replacement, resulting in severe patient morbidity and substantial healthcare costs. This investigation aimed to develop a novel strategy for preventing prosthetic loosening. Two-dimensional MXene V2C nanosheets were synthesized and subsequently immobilized onto three-dimensional porous sulfonated polyetheretherketone (SPEEK) surfaces with polydopamine (PDA) to form V2C-PDA@SPEEK (Abbrev. V2C-PS). The biocompatibility was systematically evaluated using rat bone marrow mesenchymal stem cells (rBMSCs) and murine models. The osteogenic differentiation potential of V2C-PS was assessed through real-time PCR analysis, Alkaline phosphatase (ALP) staining, and Alizarin Red staining. The in vivo osteogenic capacity of V2C-PS surrounding the implant material was evaluated in rat femoral models using micro-CT analysis, biomechanical pull-out testing, sequential fluorescent labeling of newly formed bone, and Van Gieson staining. The molecular mechanisms underlying V2C-PS -mediated osteogenic differentiation of rBMSCs were investigated both in vitro and in vivo using chemical inhibitors, β-catenin shRNA lentiviral silencing, and β-catenin mRNA lentiviral overexpression. The results demonstrated that V2C-PS exhibited excellent biocompatibility. Quantitative analysis revealed substantial upregulation (p < 0.05) of critical osteogenic markers, including RUNX2 (4.4-fold), COL-1 (5.7-fold), OCN (3.3-fold), BMP-2 (4.4-fold), OPN (3.1-fold), BSP (3.3-fold), ON (4.3-fold), and OSX (2.83-fold), in the 25V2C-PS treatment group compared to PS group. The bone parameters were also remarkably enhanced in the 25V2C-PS group (BMD increased by 241 %, bone-implant contact by 159 %, BV/TV by 225 %, Tb.N by 281 %, Tb.Th by 214 %, maximum pull-out force by 250 %, and Tp.Sp decreased by 33 %). Furthermore, V2C-PS were found to enhance rBMSC osteogenic differentiation through activation of the Wnt/β-catenin signaling pathway. This study presents a promising approach for preventing orthopedic prosthetic loosening and demonstrates significant potential for clinical translation.
Collapse
Affiliation(s)
- Shengjie Wang
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai 200233, China
| | - Wei Liu
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai 200233, China
| | - Chao Yang
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai 200233, China
| | - Xianlong Zhang
- Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, 600 Yishan Road, Shanghai 200233, China..
| | - Chunming Lyu
- Experiment Center for Science and Technology, Shanghai University of Traditional Chinese Medicine, Shanghai 201203, China.; Qinghai Province Key Laboratory of Tibetan Medicine Pharmacology and Safety Evaluation, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining 810008, China..
| |
Collapse
|
2
|
Li F, Sun D, Song Y, Zhou Z, Wang D, Cen X, Zhang Q, Gao Z, Gu Y. Dynamic simulation of knee joint mechanics: individualized multi-moment finite element modelling of patellar tendon stress during landing. J Biomech 2025; 186:112730. [PMID: 40294548 DOI: 10.1016/j.jbiomech.2025.112730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2024] [Revised: 04/17/2025] [Accepted: 04/23/2025] [Indexed: 04/30/2025]
Abstract
Patellar tendinopathy is prevalent in sports requiring high jumping demands, and understanding the in vivo biomechanical behavior of the patellar tendon (PT) during landing is crucial for developing effective injury prevention and rehabilitation strategies. This study investigates the in vivo biomechanical behavior of the PT during the landing phase of a stop-jump task, integrating musculoskeletal modelling, finite element analysis (FEA), and a high-speed dual fluoroscopic imaging system (DFIS). A subject-specific knee joint model was constructed from CT, MRI, and dynamic X-ray data for a 27-year-old male (178 cm, 68 kg) at six time points during landing. Musculoskeletal simulations were used to estimated knee joint moments and quadriceps muscle forces, which were then applied to the finite element models. DFIS ensured accurate 3D spatial alignment of the models. Ridge regression analysis explored the relationship between applied biomechanical loads and the maximum equivalent (von Mises) stress in the PT. Maximum PT stress was observed at the bone attachment sites, with the highest stress (94.44 MPa) at initial ground contact, decreasing to a minimum of 16.37 MPa during landing. Regression analysis demonstrated a significant correlation (R2 = 0.859, P < 0.001) between knee flexion moments, quadriceps muscle forces, and maximum PT stress, identifying these factors as key determinants of PT loading. This study underscores the importance of knee flexion moments and quadriceps muscle forces in influencing PT stress during landing. Future studies should include larger cohort to validate these results and explore the potential of machine learning for real-time injury risk prediction.
Collapse
Affiliation(s)
- Fengping Li
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Dong Sun
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Yang Song
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Zhanyi Zhou
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Dongxu Wang
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Xuanzhen Cen
- Faculty of Sports Science, Ningbo University, Ningbo, China
| | - Qiaolin Zhang
- Doctoral School on Safety and Security Sciences, Óbuda University, Budapest, Hungary
| | - Zixiang Gao
- Faculty of Kinesiology, University of Calgary, Calgary, Canada
| | - Yaodong Gu
- Faculty of Sports Science, Ningbo University, Ningbo, China.
| |
Collapse
|
3
|
Ammarullah MI. Integrating finite element analysis in total hip arthroplasty for childhood hip disorders: Enhancing precision and outcomes. World J Orthop 2025; 16:98871. [PMID: 39850035 PMCID: PMC11752482 DOI: 10.5312/wjo.v16.i1.98871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2024] [Revised: 12/23/2024] [Accepted: 01/02/2025] [Indexed: 01/13/2025] Open
Abstract
Total hip arthroplasty for adults with sequelae from childhood hip disorders poses significant challenges due to altered anatomy. The paper published by Oommen et al reviews the essential management strategies for these complex cases. This article explores the integration of finite element analysis (FEA) to enhance surgical precision and outcomes. FEA provides detailed biomechanical insights, aiding in preoperative planning, implant design, and surgical technique optimization. By simulating implant configurations and assessing bone quality, FEA helps in customizing implants and evaluating surgical techniques like subtrochanteric shortening osteotomy. Advanced imaging techniques, such as 3D printing, virtual reality, and augmented reality, further enhance total hip arthroplasty precision. Future research should focus on validating FEA models, developing patient-specific simulations, and promoting multidisciplinary collaboration. Integrating FEA and advanced technologies in total hip arthroplasty can improve functional outcomes, reduce complications, and enhance quality of life for patients with childhood hip disorder sequelae.
Collapse
Affiliation(s)
- Muhammad Imam Ammarullah
- Undip Biomechanics Engineering and Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| |
Collapse
|
4
|
Kholinne E, Gani KS, Mitchel, William, Wonggokusuma E, Pribadi A. Elbow stiffness due to malunited capitellum fracture: A case report and the role of 3D printing in surgical management. Int J Surg Case Rep 2024; 124:110398. [PMID: 39395254 PMCID: PMC11562399 DOI: 10.1016/j.ijscr.2024.110398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 09/26/2024] [Accepted: 09/29/2024] [Indexed: 10/14/2024] Open
Abstract
INTRODUCTION Elbow stiffness is an uncommon condition that significantly impacting a patient's daily activities. Trauma is the most frequent cause of elbow stiffness. However, capitellum fractures are rare, accounting for approximately 1 % of elbow fractures. They are often misdiagnosed due to nonspecific symptoms and the complex anatomy of the elbow joint. CASE PRESENTATION We report the case of a 54-year-old female who presented with left elbow stiffness eight months after a traumatic incident. On physical examination, her left elbow extension was +10°, and flexion was restricted to 65°, with no limitation in pronation or supination. Imaging studies revealed a malunited capitellum with osteophytes at the posterolateral site of the olecranon. A 3D-printed model of her elbow was created based on a CT scan to aid surgical planning. She underwent capsulectomy and osteotomy and was stabilized with two bioabsorbable P(L/DL)LA pins. Six months postoperatively, the patient's elbow range of motion was fully restored, and no complications were observed. CLINICAL DISCUSSION Elbow stiffness resulting from the malunion of a capitellum fracture typically necessitates surgical intervention to restore functional movement in the elbow. CONCLUSION Capitellum fractures are uncommon and frequently underdiagnosed, leading to complications such as elbow stiffness and reduced functionality. Early detection is crucial, as delayed diagnosis can result in complex management due to malunion. 3D printing from CT scans helps surgeons accurately evaluate malunions and plan precise surgical interventions.
Collapse
Affiliation(s)
- Erica Kholinne
- Gatam Institute, Eka Hospital, Indonesia; Faculty of Medicine, Universitas Trisakti, Jakarta, Indonesia.
| | | | - Mitchel
- Gatam Institute, Eka Hospital, Indonesia
| | - William
- Gatam Institute, Eka Hospital, Indonesia
| | | | | |
Collapse
|
5
|
Hidayat T, Ammarullah MI, Ismail R, Saputra E, Lamura MDP, K N C, Bayuseno AP, Jamari J. Investigation of contact behavior on a model of the dual-mobility artificial hip joint for Asians in different inner liner thicknesses. World J Orthop 2024; 15:321-336. [PMID: 38680676 PMCID: PMC11045469 DOI: 10.5312/wjo.v15.i4.321] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 01/28/2024] [Accepted: 03/25/2024] [Indexed: 04/16/2024] Open
Abstract
BACKGROUND The four components that make up the current dual-mobility artificial hip joint design are the femoral head, the inner liner, the outer liner as a metal cover to prevent wear, and the acetabular cup. The acetabular cup and the outer liner were constructed of 316L stainless steel. At the same time, the inner liner was made of ultra-high-molecular-weight polyethylene (UHMWPE). As this new dual-mobility artificial hip joint has not been researched extensively, more tribological research is needed to predict wear. The thickness of the inner liner is a significant component to consider when calculating the contact pressure. AIM To make use of finite element analysis to gain a better understanding of the contact behavior in various inner liner thicknesses on a new model of a dual-mobility artificial hip joint, with the ultimate objective of determining the inner liner thickness that was most suitable for this particular type of dual-mobility artificial hip joint. METHODS In this study, the size of the femoral head was compared between two diameters (28 mm and 36 mm) and eight inner liner thicknesses ranging from 5 mm to 12 mm. Using the finite element method, the contact parameters, including the maximum contact pressure and contact area, have been evaluated in light of the Hertzian contact theory. The simulation was performed statically with dissipated energy and asymmetric behavior. The types of interaction were surface-to-surface contact and normal contact behavior. RESULTS The maximum contact pressures in the inner liner (UHMWPE) at a head diameter of 28 mm and 36 mm are between 3.7-13.5 MPa and 2.7-10.4 MPa, respectively. The maximum von Mises of the inner liner, outer liner, and acetabular cup are 2.4-11.4 MPa, 15.7-44.3 MPa, and 3.7-12.6 MPa, respectively, for 28 mm head. Then the maximum von Mises stresses of the 36 mm head are 1.9-8.9 MPa for the inner liner, 9.9-32.8 MPa for the outer liner, and 2.6-9.9 MPa for the acetabular cup. A head with a diameter of 28 mm should have an inner liner with a thickness of 12 mm. Whereas the head diameter was 36 mm, an inner liner thickness of 8 mm was suitable. CONCLUSION The contact pressures and von Mises stresses generated during this research can potentially be exploited in estimating the wear of dual-mobility artificial hip joints in general. Contact pressure and von Mises stress reduce with an increasing head diameter and inner liner's thickness. Present findings would become one of the references for orthopedic surgery for choosing suitable bearing geometric parameter of hip implant.
Collapse
Affiliation(s)
- Taufiq Hidayat
- Department of Mechanical Engineering, Universitas Muria Kudus, Kudus 59352, Central Java, Indonesia
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Muhammad Imam Ammarullah
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Rifky Ismail
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Center for Biomechanics Biomaterials Biomechatronics and Biosignal Processing, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Eko Saputra
- Department of Mechanical Engineering, Politeknik Negeri Semarang, Semarang 50275, Central Java, Indonesia
| | - M Danny Pratama Lamura
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Chethan K N
- Department of Aeronautical and Automobile Engineering, Manipal Institute of Technology, Manipal, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India
| | | | - J Jamari
- Department of Mechanical Engineering, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
- Undip Biomechanics Engineering & Research Centre, Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| |
Collapse
|
6
|
Daher M, Haykal G, Aoun M, Moussallem M, Ghoul A, Tarchichi J, Sebaaly A. Pulsed lavage in joint arthroplasty: A systematic review and meta-analysis. World J Orthop 2024; 15:293-301. [PMID: 38596185 PMCID: PMC10999965 DOI: 10.5312/wjo.v15.i3.293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 12/26/2023] [Accepted: 02/08/2024] [Indexed: 03/15/2024] Open
Abstract
BACKGROUND Knee and hip osteoarthritis affects millions of people around the world and is expected to rise even more in frequency as the population ages. Joint arthroplasty is the surgical management of choice in these articulations. Heterotopic ossification and radiolucent lines formation are two frequent problems faced in hip and knee replacements respectively. Some studies show that the usage of pulsed lavage may prevent their formation. AIM To compare pulsed lavage to standard lavage in joint arthroplasty. METHODS PubMed, Cochrane, and Google Scholar (page 1-20) were searched till December 2023. Only comparative studies were included. The clinical outcomes evaluated were the heterotopic ossification formation in hip replacements, radiolucent lines formation, and functional knee scores in knee replacements. RESULTS Four studies met the inclusion criteria and were included in this meta-analysis. Pulsed lavage was shown to reduce the formation of radiolucent lines (P = 0.001). However, no difference was seen in the remaining outcomes. CONCLUSION Pulsed lavage reduced the formation of radiolucent lines in knee replacements. No difference was seen in the remaining outcomes. Furthermore, the clinical significance of these radiolucent lines is poorly understood. Better conducted randomized controlled studies and cost-effectivity studies are needed to reinforce these findings.
Collapse
Affiliation(s)
- Mohammad Daher
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| | - Gaby Haykal
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| | - Marven Aoun
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| | - Marc Moussallem
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| | - Ali Ghoul
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| | - Jean Tarchichi
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| | - Amer Sebaaly
- Department of Orthopedics, Saint Joseph University, Beirut 1001, Lebanon
| |
Collapse
|
7
|
Yang Z, Cui C, Zhou Z, Zheng Z, Yan S, Liu H, Qu F, Zhang K. Effect of midsole hardness and surface type cushioning on landing impact in heel-strike runners. J Biomech 2024; 165:111996. [PMID: 38377740 DOI: 10.1016/j.jbiomech.2024.111996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 01/29/2024] [Accepted: 02/13/2024] [Indexed: 02/22/2024]
Abstract
High loading impact associated with heel strikes causes running injuries. This study aimed to investigate how loading impact is affected by midsole hardness and running surface type. Twelve young rear-foot runners ran at a fixed speed along an 18 m runway wearing shoes with different midsole hardness (Asker C-45, C-50, C-55, C-60, from soft to hard) and on two different surfaces (rubber and concrete). We quantified vertical average loading rate (VALR) and vertical impact peak force (VIPF). We conducted midsole × surface repeated-measures ANOVA on loading impact measures, and one-sample t-tests to compare VALR with a threshold value (80 BW·s-1). Midsole hardness and surface type mainly affected VALR. Although no significant effect of these variables was observed for VIPF magnitude, there were effects on time to VIPF and steps with VIPF. Several combinations of midsole and surface hardness reduced VALR below 80 BW·s-1: Asker C-45 with both surfaces, and Asker C-50 with a rubber surface. The combination of softer midsole and surface effectively reduced loading rates as shown by increased time to VIPF and reduced VALR. Combining softer midsole and surface results in the greatest cushioning, which demonstrates the benefit of considering both factors in reducing running injuries.
Collapse
Affiliation(s)
- Zihan Yang
- Fashion Accessory Art and Engineering College, Beijing Institute of Fashion Technology, Beijing, China; School of Biomedical Engineering, Capital Medical University, Beijing, China; Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China; Biomechanics Laboratory, Beijing Sport University, Beijing, China
| | - Chuyi Cui
- Department of Neurology and Neurological Sciences, Stanford University School of Medicine, Stanford, CA, USA
| | - Zhipeng Zhou
- College of Sports and Health, Shandong Sport University, Jinan, Shandong, China
| | - Zhiyi Zheng
- Anta (China) Co., Ltd. Anta Sports Science Laboratory, Xiamen, Fujian, China
| | - Songhua Yan
- School of Biomedical Engineering, Capital Medical University, Beijing, China; Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
| | - Hui Liu
- Biomechanics Laboratory, Beijing Sport University, Beijing, China
| | - Feng Qu
- Biomechanics Laboratory, Beijing Sport University, Beijing, China
| | - Kuan Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, China; Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China.
| |
Collapse
|
8
|
Nitiwarangkul L, Hongku N, Pattanaprateep O, Rattanasiri S, Woratanarat P, Thakkinstian A. Which approach of total hip arthroplasty is the best efficacy and least complication? World J Orthop 2024; 15:73-93. [PMID: 38293261 PMCID: PMC10824060 DOI: 10.5312/wjo.v15.i1.73] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 12/20/2023] [Accepted: 12/29/2023] [Indexed: 01/16/2024] Open
Abstract
BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function. Approaches of the hip have been exhaustively explored about pros and cons. The efficacy and the complications of hip approaches remains inconclusive. This study conducted an umbrella review to systematically appraise previous meta-analysis (MAs) including conventional posterior approach (PA), and minimally invasive surgeries as the lateral approach (LA), direct anterior approach (DAA), 2-incisions method, mini-lateral approach and the newest technique direct superior approach (DSA) or supercapsular percutaneously-assisted total hip (SuperPath). AIM To compare the efficacy and complications of hip approaches that have been published in all MAs and randomized controlled trials (RCTs). METHODS MAs were identified from MEDLINE and Scopus from inception until 2023. RCTs were then updated from the latest MA to September 2023. This study included studies which compared hip approaches and reported at least one outcome such as Harris Hip Score (HHS), dislocation, intra-operative fracture, wound complication, nerve injury, operative time, operative blood loss, length of hospital stay, incision length and VAS pain. Data were independently selected, extracted and assessed by two reviewers. Network MA and cluster rank and surface under the cumulative ranking curve (SUCRA) were estimated for treatment efficacy and safety. RESULTS Finally, twenty-eight MAs (40 RCTs), and 13 RCTs were retrieved. In total 47 RCTs were included for reanalysis. The results of corrected covered area showed high degree (13.80%). Among 47 RCTs, most of the studies were low risk of bias in part of random process and outcome reporting, while other domains were medium to high risk of bias. DAA significantly provided higher HHS at three months than PA [pooled unstandardized mean difference (USMD): 3.49, 95% confidence interval (CI): 0.98, 6.00 with SUCRA: 85.9], followed by DSA/SuperPath (USMD: 1.57, 95%CI: -1.55, 4.69 with SUCRA: 57.6). All approaches had indifferent dislocation and intraoperative fracture rates. SUCRA comparing early functional outcome and composite complications (dislocation, intra-operative fracture, wound complication, and nerve injury) found DAA was the best approach followed by DSA/SuperPath. CONCLUSION DSA/SuperPath had better earlier functional outcome than PA, but still could not overcome the result of DAA. This technique might be the other preferred option with acceptable complications.
Collapse
Affiliation(s)
- Lertkong Nitiwarangkul
- Clinical Epidemiology and Biostatistics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
- Orthopaedics Surgery, Police General Hospital, Bangkok 10330, Thailand
| | - Natthapong Hongku
- Department of Orthopaedics, Faculty of Medicine Vajira Hospital, Navamindrahiraj University, Bangkok 10300, Thailand
| | - Oraluck Pattanaprateep
- Clinical Epidemiology and Biostatistics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Sasivimol Rattanasiri
- Clinical Epidemiology and Biostatistics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Patarawan Woratanarat
- Department of Orthopaedics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| | - Ammarin Thakkinstian
- Clinical Epidemiology and Biostatistics, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand
| |
Collapse
|
9
|
Tedeschi R. Case study: Gait assessment of a patient with hallux rigidus before and after plantar modification. Int J Surg Case Rep 2024; 114:109197. [PMID: 38150995 PMCID: PMC10800719 DOI: 10.1016/j.ijscr.2023.109197] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 12/19/2023] [Accepted: 12/20/2023] [Indexed: 12/29/2023] Open
Abstract
INTRODUCTION AND IMPORTANCE Hallux rigidus (HR) is a degenerative arthritis affecting the first metatarsophalangeal joint (MTP), leading to pain and functional impairment, particularly during the propulsive phase of walking. The prevalence of HR is about 2.5 % in individuals over 50, but younger individuals can also be affected, as demonstrated in this case. CASE PRESENTATION We report the case of a 26-year-old patient with a body mass index (BMI) of 20.2, who has been suffering from HR for 5 years. The patient presented with walking difficulties, characterized by a limp and impaired propulsion phase, and pain in the right foot due to HR. A comprehensive gait assessment was conducted using a baropodometric platform and integrated smartphone motion sensors. Following the diagnosis, a non-surgical intervention involving the application of a compressed cotton felt foot orthosis at the MTP plantar area was initiated. This intervention aimed to alleviate pain and improve the functional mobility of the right big toe. Post-treatment assessments showed an increase in the big toe's mobility from 0 degrees to 35 degrees, as measured by a digital goniometer. CLINICAL DISCUSSION The application of a soft support, such as compressed cotton felt, at the plantar area of MTP, demonstrated a potential non-surgical therapeutic approach to improve gait and reduce discomfort in HR patients. CONCLUSION This case study underscores the potential benefits of plantar modification in the management of HR.
Collapse
Affiliation(s)
- Roberto Tedeschi
- Department of Biomedical and Neuromotor Sciences (DIBINEM), University of Bologna, Bologna, Italy.
| |
Collapse
|
10
|
Zhang H, Zhang J, Lai J, Chen Y, Tian M, Pan G, Yang X, Qi Y. Nanoscale Surface Refinement of CoCrMo Alloy for Artificial Knee Joints via Chemical Mechanical Polishing. MATERIALS (BASEL, SWITZERLAND) 2023; 17:8. [PMID: 38203862 PMCID: PMC10779557 DOI: 10.3390/ma17010008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 12/10/2023] [Accepted: 12/14/2023] [Indexed: 01/12/2024]
Abstract
In this study, we address the challenge of surface roughness in CoCrMo alloys, typically used in artificial knee joints, which can initiate a cascade of biological responses causing inflammation, osteolysis, joint instability, and increased susceptibility to infection. We propose the application of a chemical mechanical polishing (CMP) technique, using an ecologically responsible slurry composed of 4 wt% SiO2, 0.3 wt% H2O2, 1.0 wt% glycine, and 0.05 wt% benzotriazole. Our innovative approach demonstrated significant improvements, achieving a material removal rate of 30.9 nm/min and reducing the arithmetic mean roughness from 20.76 nm to 0.25 nm, thereby enhancing the nanoscale surface quality of the artificial knee joint alloy. The smoother surface is attributed to a decrease in corrosion potential to 0.18 V and a reduction in corrosion current density from 9.55 µA/cm2 to 4.49 µA/cm2 with the addition of BTA, evidenced by electrochemical tests. Furthermore, the preservation of the phase structure of the CoCrMo alloy, as confirmed by XRD analysis and elemental mapping, ensures the structural integrity of the treated surfaces. These outcomes and our simulation results demonstrate the effectiveness of our CMP method in engineering surface treatments for artificial knee joints to optimize friction behavior and potentially extend their lifespans.
Collapse
Affiliation(s)
- Hanji Zhang
- Department of Orthopedics, Tianjin Union Medical Center, Nankai University Affiliated Hospital, Tianjin 300121, China;
- School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300130, China; (J.Z.); (J.L.); (G.P.)
| | - Jiangliang Zhang
- School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300130, China; (J.Z.); (J.L.); (G.P.)
| | - Jinghui Lai
- School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300130, China; (J.Z.); (J.L.); (G.P.)
| | - Yilin Chen
- The Second Clinical College, China Medical University, Shenyang 110001, China;
| | - Mengqiang Tian
- Department of Orthopedics, Tianjin Union Medical Center, Nankai University Affiliated Hospital, Tianjin 300121, China;
| | - Guofeng Pan
- School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300130, China; (J.Z.); (J.L.); (G.P.)
| | - Xueli Yang
- School of Electronics and Information Engineering, Hebei University of Technology, Tianjin 300130, China; (J.Z.); (J.L.); (G.P.)
| | - Yuhang Qi
- Department of Orthopedics, Tianjin Union Medical Center, Nankai University Affiliated Hospital, Tianjin 300121, China;
| |
Collapse
|
11
|
Alqahtani AR, Desai SR, Patel JR, Alqhtani NR, Alqahtani AS, Heboyan A, Fernandes GVO, Mustafa M, Karobari MI. Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis. BMC Oral Health 2023; 23:686. [PMID: 37740190 PMCID: PMC10517556 DOI: 10.1186/s12903-023-03370-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 08/30/2023] [Indexed: 09/24/2023] Open
Abstract
BACKGROUND Dental implants emerge as a dependable and efficacious alternative for patients experiencing partial or complete tooth loss. The stability of these implants is influenced by surface topography and macro-level design. In cases where the height of the maxillary posterior region is diminished, employing short implants can prove advantageous. With the aim of examining the distribution of von Mises stress, strain, and micromovement in D4 bone quality surrounding platform-switched short implants, measuring 6 mm in length and featuring diameters ranging from 4 to 6 mm, as well as different thread designs, an in-depth finite element analysis was conducted under immediate loading conditions. METHODOLOGY A 3D finite element model was constructed to simulate maxillary molar crowns, incorporating an implant with a length of 6 mm and varying diameters and thread designs. The diameters utilized were 4/3.6 mm, 5/4 mm, and 6/4.8 mm, while the thread designs included buttress, square, and triangle patterns. Each model underwent analysis with a 100 N force applied in two directions: vertical and oblique, relative to the long axis of the implant. Stress, strain, and micromovement in the peri-implant region were recorded, employing the Ansys Workbench R v.18.1 software for modelling and analysis. RESULTS When comparing all three diameters, the wide diameter (6 mm threads) exhibited the lowest values of peri-implant von Mises stresses (3.3 MPa and 35.1 MPa), strains (194 Ɛ and 484 Ɛ), and micromovements (0.7 μm and 1.3 Ɛ) subjected to axial and non-axial loading of a 100 N force. Notably, square microthreads yielded the most favorable stress parameters among the different thread shapes, manifesting the minimum values of stress, strains, and micromovements in their vicinity. CONCLUSION For the treatment of atrophic ridges or in scenarios necessitating extensive surgical preparation of the implant site, a combination of short implants, wide diameters, and platform switching can be employed. In situations with reduced bone height and the requirement for an implant-supported prosthesis to replace a missing permanent maxillary molar, the utilization of wide-diameter platform-switched short implants measuring 6 mm in length, featuring a square thread design, should be taken into consideration.
Collapse
Affiliation(s)
- Ali Robaian Alqahtani
- Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, 11942 Saudi Arabia
| | - Shrikar R. Desai
- Department of Periodontology and Implantology, HKE’S S. Nijalingappa Institute of Dental Sciences and Research, Kalaburagi, 585105 India
| | - Jignesh R. Patel
- Dr. Patel’s Specialty Dental Care, 203, Silver Empire, Opposite Utran Power House Gate, VIP Circle, Utran, 394107 Surat India
| | - Nasser Raqe Alqhtani
- Department of Oral and Maxillofacial Surgery and Diagnostic Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, 11942 Saudi Arabia
| | - Abdullah Saad Alqahtani
- Department of Preventive Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, 11942 Saudi Arabia
| | - Artak Heboyan
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University, Mkhitar Heratsi, Str. Koryun 2, Yerevan, 0025 Armenia
| | - Gustavo V. O. Fernandes
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, 1011 North University Ave, Ann Arbor, MI 48109 USA
| | - Mohammed Mustafa
- Department of Conservative Dental Sciences, College of Dentistry, Prince Sattam Bin Abdulaziz University, Al-Kharj, 11942 Saudi Arabia
| | - Mohamed Isaqali Karobari
- Department of Restorative Dentistry & Endodontics, Faculty of Dentistry, University of Puthisastra, 12211 Phnom Penh, Cambodia
- Center for Global health Research, Saveetha Institute of Medical and Technical Sciences, Saveetha Medical College and Hospitals, Saveetha University, Kuthambakkam, India
| |
Collapse
|
12
|
Kononova S, Kashparov M, Xue W, Bobkova N, Leonov S, Zagorodny N. Gut Microbiome Dysbiosis as a Potential Risk Factor for Idiopathic Toe-Walking in Children: A Review. Int J Mol Sci 2023; 24:13204. [PMID: 37686011 PMCID: PMC10488280 DOI: 10.3390/ijms241713204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/10/2023] Open
Abstract
Idiopathic toe walking (ITW) occurs in about 5% of children. Orthopedic treatment of ITW is complicated by the lack of a known etiology. Only half of the conservative and surgical methods of treatment give a stable positive result of normalizing gait. Available data indicate that the disease is heterogeneous and multifactorial. Recently, some children with ITW have been found to have genetic variants of mutations that can lead to the development of toe walking. At the same time, some children show sensorimotor impairment, but these studies are very limited. Sensorimotor dysfunction could potentially arise from an imbalanced production of neurotransmitters that play a crucial role in motor control. Using the data obtained in the studies of several pathologies manifested by the association of sensory-motor dysfunction and intestinal dysbiosis, we attempt to substantiate the notion that malfunction of neurotransmitter production is caused by the imbalance of gut microbiota metabolites as a result of dysbiosis. This review delves into the exciting possibility of a connection between variations in the microbiome and ITW. The purpose of this review is to establish a strong theoretical foundation and highlight the benefits of further exploring the possible connection between alterations in the microbiome and TW for further studies of ITW etiology.
Collapse
Affiliation(s)
- Svetlana Kononova
- Institute of Protein Research, Russian Academy of Sciences, 142290 Pushchino, Russia
| | - Mikhail Kashparov
- Department of Traumatology and Orthopedics, Peoples’ Friendship University of Russia, 117198 Moscow, Russia; (M.K.); (N.Z.)
- Scientific and Practical Center for Child Psychoneurology, 119602 Moscow, Russia
| | - Wenyu Xue
- School of Biological and Medical Physics, Moscow Institute of Physics and Technology, 141700 Dolgoprudny, Russia; (W.X.); (S.L.)
| | - Natalia Bobkova
- Institute of Cell Biophysics, Russian Academy of Sciences, 142290 Pushchino, Russia;
| | - Sergey Leonov
- School of Biological and Medical Physics, Moscow Institute of Physics and Technology, 141700 Dolgoprudny, Russia; (W.X.); (S.L.)
- Institute of Cell Biophysics, Russian Academy of Sciences, 142290 Pushchino, Russia;
| | - Nikolaj Zagorodny
- Department of Traumatology and Orthopedics, Peoples’ Friendship University of Russia, 117198 Moscow, Russia; (M.K.); (N.Z.)
- N.N. Priorov Central Research Institute of Traumatology and Orthopedics, 127299 Moscow, Russia
| |
Collapse
|
13
|
Demirel A, Özgünay ŞE, Eminoğlu Ş, Balkaya AN, Onur T, Kılıçarslan N, Gamlı M. Ultrasonographic Evaluation of Gastric Content and Volume in Pediatric Patients Undergoing Elective Surgery: A Prospective Observational Study. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1432. [PMID: 37761393 PMCID: PMC10529717 DOI: 10.3390/children10091432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 08/11/2023] [Accepted: 08/17/2023] [Indexed: 09/29/2023]
Abstract
Anesthesia-related complications, such as pulmonary aspiration of gastric contents, occur in approximately 0.02-0.1% of elective pediatric surgeries. Aspiration risk can be reliably assessed by ultrasound examination of the gastric antrum, making it an essential non-invasive bedside tool. In this prospective observational study, since most of our patients are immigrants and have communication problems, we wanted to investigate gastric contents and the occurrence of "high risk stomach" in children undergoing elective surgery for the possibility of pulmonary aspiration, even if the children and/or parents reported their last oral intake time. This risk is defined by ultrasound findings of solid content in the antrum and/or a calculated gastric volume exceeding 1.25 mL/kg. Children aged 2-18 were included in the study. Both supine and right lateral decubitus (RLD) ultrasound examinations were performed on the antrum before surgery. Using a qualitative grading scale from 0 to 2, we evaluated the gastric fluid content. The cross-sectional area (CSA) of the antrum was measured in the RLD position, aiding the calculation of the gastric fluid volume according to an established formula by Perlas. Ultrasound measurements of 97 children were evaluated. The median fasting duration was 4 h for liquids and 9 h for thick liquids and solids. Solid content was absent in all the children. Five children (5.2%) exhibited a grade 2 antrum, implying that fluid content was visible in both the supine and RLD positions. The median antral CSA in the RLD was 2.36 cm2, with a median gastric volume of 0.46 mL/kg. For patients with a grade 0 antrum, a moderate and positive correlation was observed between the antral CSA and BMI, and a strong and positive correlation was evident between the antral CSA and age, similar to a grade 1 antrum. Only a single child (1%) had a potentially elevated risk of aspiration of gastric contents. Hence, the occurrence of a "high risk stomach" was 1% (95% confidence interval: 0.1-4.7%) and is consistent with the literature. As a necessary precaution, we propose the regular use of ultrasound evaluations of gastric contents, given their non-invasive, bedside-friendly, and straightforward implementation, for identifying risks when fasting times are uncertain and for ruling out unknown risk factors in each potential patient.
Collapse
Affiliation(s)
- Asiye Demirel
- Department of Anesthesiology and Reanimation, Bursa Yuksek Ihtisas Training and Research Hospital, University of Health Sciences, Bursa 16310, Turkey; (Ş.E.Ö.); (Ş.E.); (A.N.B.); (T.O.); (N.K.); (M.G.)
| | | | | | | | | | | | | |
Collapse
|
14
|
Bogey R. An EMG-to-Force Processing Approach to Estimating Knee Muscle Forces during Adult, Self-Selected Speed Gait. Bioengineering (Basel) 2023; 10:980. [PMID: 37627865 PMCID: PMC10451826 DOI: 10.3390/bioengineering10080980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 08/09/2023] [Accepted: 08/18/2023] [Indexed: 08/27/2023] Open
Abstract
BACKGROUND The purpose of this study was to determine the force production during self-selected speed normal gait by muscle-tendon units that cross the knee. The force of a single knee muscle is not directly measurable without invasive methods, yet invasive techniques are not appropriate for clinical use. Thus, an EMG-to-force processing (EFP) model was developed which scaled muscle-tendon unit (MTU) force output to gait EMG. METHODS An EMG-to-force processing (EFP) model was developed which scaled muscle-tendon unit (MTU) force output to gait EMG. Active muscle force power was defined as the product of MTU forces (derived from EFP) and that muscle's contraction velocity. Net knee EFP moment was determined by summing individual active knee muscle moments. Net knee moments were also calculated for these study participants via inverse dynamics (kinetics plus kinematics, KIN). The inverse dynamics technique used are well accepted and the KIN net moment was used to validate or reject this model. Closeness of fit of the moment power curves for the two methods (during active muscle forces) was used to validate the model. RESULTS The correlation between the EFP and KIN methods was sufficiently close, suggesting validation of the model's ability to provide reasonable estimates of knee muscle forces. CONCLUSIONS The EMG-to-force processing approach provides reasonable estimates of active individual knee muscle forces in self-selected speed walking in neurologically intact adults.
Collapse
Affiliation(s)
- Ross Bogey
- Department of Physical Medicine and Rehabilitation, Western University of the Health Sciences, 309 East 2nd Street, Pomona, CA 91766, USA
| |
Collapse
|
15
|
Cheng MK, Guo YY, Kang XN, Zhang L, Wang D, Ren HH, Yuan G. Advances in cardiovascular-related biomarkers to predict diabetic peripheral neuropathy. World J Diabetes 2023; 14:1226-1233. [PMID: 37664477 PMCID: PMC10473952 DOI: 10.4239/wjd.v14.i8.1226] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 06/24/2023] [Accepted: 07/07/2023] [Indexed: 08/11/2023] Open
Abstract
Diabetic peripheral neuropathy (DPN) is a common chronic complication of diabetes mellitus. One of the most common types is distal symmetric poly-neuropathy, which begins as bilateral symmetry pain and hyperesthesia and gradually progresses into hypoesthesia with nerve fibre disorder and is frequently accompanied by depression and anxiety. Notably, more than half of patients with DPN can be asymptomatic, which tends to delay early detection. Furthermore, the study of adverse outcomes showed that DPN is a prominent risk factor for foot ulceration, gangrene and nontraumatic amputation, which decreases quality of life. Thus, it is essential to develop convenient diagnostic biomarkers with high sensitivity for screening and early intervention. It has been reported that there may be common pathways for microvascular and macrovascular complications of diabetes. The pathogenesis of both disorders involves vascular endothelial dys-function. Emerging evidence indicates that traditional and novel cardiovascular-related biomarkers have the potential to characterize patients by subclinical disease status and improve risk prediction. Additionally, beyond traditional cardiovascular-related biomarkers, novel cardiovascular-related biomarkers have been linked to diabetes and its complications. In this review, we evaluate the association between major traditional and nontraditional car-diovascular-related biomarkers of DPN, such as cardiac troponin T, B-type natriuretic peptide, C-reactive protein, myeloperoxidase, and homocysteine, and assess the evidence for early risk factor-based management strategies to reduce the incidence and slow the progression of DPN.
Collapse
Affiliation(s)
- Meng-Ke Cheng
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| | - Yao-Yao Guo
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| | - Xiao-Nan Kang
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| | - Lu Zhang
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| | - Dan Wang
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| | - Hui-Hui Ren
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| | - Gang Yuan
- Department of Endocrinology, Tongji Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan 430030, Hubei Province, China
| |
Collapse
|
16
|
Miah MS, Rahman MM, Hoque MA, Ibrahim SM, Sultan M, Shamshiri RR, Ucgul M, Hasan M, Barna TN. Design and evaluation of a power tiller vegetable seedling transplanter with dibbler and furrow type. Heliyon 2023; 9:e17827. [PMID: 37533994 PMCID: PMC10392037 DOI: 10.1016/j.heliyon.2023.e17827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 06/18/2023] [Accepted: 06/28/2023] [Indexed: 08/04/2023] Open
Abstract
Vegetable production plays a vital role in ensuring food security in Bangladesh. However, the majority of vegetable seedlings are currently transplanted manually, which is not only time-consuming but also labor-intensive and costly. In this context, a semi-automated transplanter can be considered as an alternative solution for mechanized seedling transplanting. To mechanize seedling operations, two types of transplanters were designed, fabricated and tested: the power tiller-operated semi-automatic dibbler vegetable seedling (DVS) transplanter and the furrow opener vegetable seedling (FVS) transplanter. The goal was to evaluate their performance and impact on field crop productivity. In the DVS transplanter design, the larger sprocket was adjusted to enhance the precision of hole-making by pressing the dibbler into the soil, creating holes where seedlings would be transplanted. On the other hand, the FVS transplanter utilized a furrow opener to create furrows, and the seedling is placed in these furrow at a specific distance from the furrow opener wall, where the distance between seedlings within the furrow could be adjusted based on the specific requirements of the seedling crop. The results of the evaluation indicated that both transplanters successfully planted seedlings without any missing placements, while hole covering was achieved at 115 and 118.2% for the DVS and FVS transplanters, respectively. The field capacity and field efficiency for both transplanters were determined to be 0.05 ha h-1 and 61.18%, respectively, with a coefficient of variation of 5% or less. Field tests conducted with brinjal crops at a forward speed of 1.2 km h-1 and a spacing of 0.7 × 0.6 m demonstrated that both designs yielded higher yield productivity compared to manual transplantation. Additionally, no issues related to vegetative development were observed. Both transplanters exhibited promising performance and significant potential in terms of accurately transplanting seedlings, and ensuring satisfactory transplantation quality. Furthermore, these transplanters offer several advantages, including less time-consuming, lower labor demands and even distribution of seedlings. This design encourages small to medium-level farmers seeking to engage in mechanized vegetable farming practices.
Collapse
Affiliation(s)
- Md Sumon Miah
- Farm Machinery and Postharvest Process Engineering Division, Bangladesh Agricultural Research Institute, Joydebpur, Gazipur, 1701, Bangladesh
| | - Md Mashiur Rahman
- Agricultural Engineering Division, Pulses Research Center & Regional Agricultural Research Station, Bangladesh Agricultural Research Institute, Ishurdi, 6620, Pabna, Bangladesh
| | - Muhammad Arshadul Hoque
- Farm Machinery and Postharvest Process Engineering Division, Bangladesh Agricultural Research Institute, Joydebpur, Gazipur, 1701, Bangladesh
| | - Sobhy M. Ibrahim
- Department of Biochemistry, College of Science, King Saud University, P.O. Box 2455, Riyadh, 11451, Saudi Arabia
| | - Muhammad Sultan
- Department of Agricultural Engineering, Bahauddin Zakariya University, Multan, 60800, Pakistan
| | - Redmond R. Shamshiri
- Department of Engineering for Crop Production, Leibniz Institute for Agricultural Engineering and Bioeconomy, 14469, Potsdam, Germany
| | - Mustafa Ucgul
- Faculty of Science and Engineering, Southern Cross University, Lismore, NSW, 2480, Australia
| | - Mahedi Hasan
- Farm Machinery and Postharvest Process Engineering Division, Bangladesh Agricultural Research Institute, Joydebpur, Gazipur, 1701, Bangladesh
| | - Tasneem Nahar Barna
- Farm Machinery and Postharvest Process Engineering Division, Bangladesh Agricultural Research Institute, Joydebpur, Gazipur, 1701, Bangladesh
| |
Collapse
|
17
|
Giordano C, Sciarrone MA, Vitali F, Romano A, Guerri G, Perlangeli V, Gaudino S, Luigetti M. Nerve MR in the Differential Diagnosis of Neuropathies: A Case Series from a Single Center. J Clin Med 2023; 12:5009. [PMID: 37568411 PMCID: PMC10419791 DOI: 10.3390/jcm12155009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/20/2023] [Accepted: 07/28/2023] [Indexed: 08/13/2023] Open
Abstract
In the present study, through a case series, we highlighted the role of magnetic resonance (MR) in the identification and diagnosis of peripheral neuropathies. MR neurography allows the evaluation of the course of nerves through 2D and 3D STIR sequences with an isotropic voxel, whereas the relationship between nerves, vessels, osteo-ligamentous and muscular structures can be appraised with T1 sequences. Currently, DTI and tractography are mainly used for experimental purposes. MR neurography can be useful in detecting subtle nerve alterations, even before the onset of symptoms. However, despite being sensitive, MR neurography is not specific in detecting nerve injury and requires careful interpretation. For this reason, MR information should always be supported by instrumental clinical tests.
Collapse
Affiliation(s)
- Carolina Giordano
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico “A. Gemelli” IRCCS, 00168 Rome, Italy; (C.G.); (S.G.)
- Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (M.A.S.); (F.V.); (G.G.); (V.P.)
| | | | - Francesca Vitali
- Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (M.A.S.); (F.V.); (G.G.); (V.P.)
| | - Angela Romano
- Dipartimento Neuroscienze, Organi di Senso e Torace, Fondazione Policlinico “A. Gemelli” IRCCS, 00168 Rome, Italy;
| | - Giulia Guerri
- Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (M.A.S.); (F.V.); (G.G.); (V.P.)
| | - Valentina Perlangeli
- Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (M.A.S.); (F.V.); (G.G.); (V.P.)
| | - Simona Gaudino
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico “A. Gemelli” IRCCS, 00168 Rome, Italy; (C.G.); (S.G.)
- Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (M.A.S.); (F.V.); (G.G.); (V.P.)
| | - Marco Luigetti
- Università Cattolica del Sacro Cuore, 00168 Rome, Italy; (M.A.S.); (F.V.); (G.G.); (V.P.)
- Dipartimento Neuroscienze, Organi di Senso e Torace, Fondazione Policlinico “A. Gemelli” IRCCS, 00168 Rome, Italy;
| |
Collapse
|
18
|
Kaniewska M, Deininger-Czermak E, Lohezic M, Ensle F, Guggenberger R. Deep Learning Convolutional Neural Network Reconstruction and Radial k-Space Acquisition MR Technique for Enhanced Detection of Retropatellar Cartilage Lesions of the Knee Joint. Diagnostics (Basel) 2023; 13:2438. [PMID: 37510182 PMCID: PMC10378433 DOI: 10.3390/diagnostics13142438] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Revised: 07/13/2023] [Accepted: 07/15/2023] [Indexed: 07/30/2023] Open
Abstract
OBJECTIVES To assess diagnostic performance of standard radial k-space (PROPELLER) MRI sequences and compare with accelerated acquisitions combined with a deep learning-based convolutional neural network (DL-CNN) reconstruction for evaluation of the knee joint. METHODS Thirty-five patients undergoing MR imaging of the knee at 1.5 T were prospectively included. Two readers evaluated image quality and diagnostic confidence of standard and DL-CNN accelerated PROPELLER MR sequences using a four-point Likert scale. Pathological findings of bone, cartilage, cruciate and collateral ligaments, menisci, and joint space were analyzed. Inter-reader agreement (IRA) for image quality and diagnostic confidence was assessed using intraclass coefficients (ICC). Cohen's Kappa method was used for evaluation of IRA and consensus between sequences in assessing different structures. In addition, image quality was quantitatively evaluated by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. RESULTS Mean acquisition time of standard vs. DL-CNN sequences was 10 min 3 s vs. 4 min 45 s. DL-CNN sequences showed significantly superior image quality and diagnostic confidence compared to standard MR sequences. There was moderate and good IRA for assessment of image quality in standard and DL-CNN sequences with ICC of 0.524 and 0.830, respectively. Pathological findings of the knee joint could be equally well detected in both sequences (κ-value of 0.8). Retropatellar cartilage could be significantly better assessed on DL-CNN sequences. SNR and CNR was significantly higher for DL-CNN sequences (both p < 0.05). CONCLUSIONS In MR imaging of the knee, DL-CNN sequences showed significantly higher image quality and diagnostic confidence compared to standard PROPELLER sequences, while reducing acquisition time substantially. Both sequences perform comparably in the detection of knee-joint pathologies, while DL-CNN sequences are superior for evaluation of retropatellar cartilage lesions.
Collapse
Affiliation(s)
- Malwina Kaniewska
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Raemistrasse 100, 8091 Zurich, Switzerland
- Institute of Diagnostic and Interventional Radiology, University of Zurich (UZH), Raemistrasse 100, 8091 Zurich, Switzerland
| | - Eva Deininger-Czermak
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Raemistrasse 100, 8091 Zurich, Switzerland
- Institute of Diagnostic and Interventional Radiology, University of Zurich (UZH), Raemistrasse 100, 8091 Zurich, Switzerland
- Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, 8152 Zurich, Switzerland
| | - Maelene Lohezic
- Advanced Technology, Science and Technology Organization, GE HealthCare, 8152 Zurich, Switzerland
| | - Falko Ensle
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Raemistrasse 100, 8091 Zurich, Switzerland
- Institute of Diagnostic and Interventional Radiology, University of Zurich (UZH), Raemistrasse 100, 8091 Zurich, Switzerland
| | - Roman Guggenberger
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich (USZ), Raemistrasse 100, 8091 Zurich, Switzerland
- Institute of Diagnostic and Interventional Radiology, University of Zurich (UZH), Raemistrasse 100, 8091 Zurich, Switzerland
| |
Collapse
|
19
|
Wang Y, Ma JX, Bai HH, Lu B, Sun L, Jin HZ, Ma XL. Mechanical analysis of the femoral neck dynamic intersection system with different nail angles and clinical applications. World J Clin Cases 2023; 11:4814-4823. [PMID: 37584003 PMCID: PMC10424033 DOI: 10.12998/wjcc.v11.i20.4814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/07/2023] [Accepted: 06/25/2023] [Indexed: 07/11/2023] Open
Abstract
BACKGROUND The femoral neck dynamic intersection system (FNS) is mechanically more stable than other internal fixation techniques. Current studies have confirmed that the structural design of FNS has good biomechanical properties in European and American populations. However, whether the suitability of the FNS's 130° main nail angle design for Asian populations has been thoroughly investigated remains unclear. AIM To compare the biomechanical stability differences among different main nail angles of the FNS in the treatment of femoral neck fractures in Asian populations. METHODS Computed tomography data of the femur of healthy adult male volunteers were imported into Mimics software to create a three-dimensional model of the femur. The model was adapted to the curve using Geomagic software and imported into Solidworks software to construct the Pauwels I femoral neck fracture model and design the FNS internal fixation model using different main nail angles. Afterward, the models were assembled with the FNS fracture model and meshed using the preprocessing Hypermesh software. Subsequently, they were imported into Abaqus software to analyze and evaluate the biomechanical effects of different angles of the FNS main nail on the treatment of femoral neck fractures. RESULTS The peak displacement of the proximal femur under different angles of FNS fixation under stress was 7.446 millimeters in the 120° group and 7.416 millimeters in the 125° group; in the 130°, 135°, and 140° FNS fixation groups, the peak displacement was 7.324 millimeters, 8.138 millimeters, and 8.246 millimeters, respectively. In the 120° and 125° FNS fixation groups, the maximum stresses were concentrated at the main nail and the anti-rotation screw, which intersected the fracture line of the femur neck, resulting in peak stresses of 200.7 MPa and 138.8 MPa, respectively. Peak stresses of 208.8 MPa, 219.8 MPa, and 239.3 MPa were observed on the angular locking plate distal to the locking screw in the 130°, 135°, and 140° fixation groups. CONCLUSION FNS has significant stress distribution properties, a minimal proximal femoral displacement, and an optimal stability for treating femoral neck fractures in Asian populations when performed with a 130° main nail angle.
Collapse
Affiliation(s)
- Ying Wang
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Jian-Xiong Ma
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Hao-Hao Bai
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Bin Lu
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Lei Sun
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Hong-Zhen Jin
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Xin-Long Ma
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| |
Collapse
|
20
|
Wang Y, Ma JX, Bai HH, Lu B, Sun L, Jin HZ, Ma XL. Mechanical analysis of the femoral neck dynamic intersection system with different nail angles and clinical applications. World J Clin Cases 2023; 11:4810-4819. [DOI: 10.12998/wjcc.v11.i20.4810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/07/2023] [Accepted: 06/25/2023] [Indexed: 07/06/2023] Open
Abstract
BACKGROUND The femoral neck dynamic intersection system (FNS) is mechanically more stable than other internal fixation techniques. Current studies have confirmed that the structural design of FNS has good biomechanical properties in European and American populations. However, whether the suitability of the FNS's 130° main nail angle design for Asian populations has been thoroughly investigated remains unclear.
AIM To compare the biomechanical stability differences among different main nail angles of the FNS in the treatment of femoral neck fractures in Asian populations.
METHODS Computed tomography data of the femur of healthy adult male volunteers were imported into Mimics software to create a three-dimensional model of the femur. The model was adapted to the curve using Geomagic software and imported into Solidworks software to construct the Pauwels I femoral neck fracture model and design the FNS internal fixation model using different main nail angles. Afterward, the models were assembled with the FNS fracture model and meshed using the preprocessing Hypermesh software. Subsequently, they were imported into Abaqus software to analyze and evaluate the biomechanical effects of different angles of the FNS main nail on the treatment of femoral neck fractures.
RESULTS The peak displacement of the proximal femur under different angles of FNS fixation under stress was 7.446 millimeters in the 120° group and 7.416 millimeters in the 125° group; in the 130°, 135°, and 140° FNS fixation groups, the peak displacement was 7.324 millimeters, 8.138 millimeters, and 8.246 millimeters, respectively. In the 120° and 125° FNS fixation groups, the maximum stresses were concentrated at the main nail and the anti-rotation screw, which intersected the fracture line of the femur neck, resulting in peak stresses of 200.7 MPa and 138.8 MPa, respectively. Peak stresses of 208.8 MPa, 219.8 MPa, and 239.3 MPa were observed on the angular locking plate distal to the locking screw in the 130°, 135°, and 140° fixation groups.
CONCLUSION FNS has significant stress distribution properties, a minimal proximal femoral displacement, and an optimal stability for treating femoral neck fractures in Asian populations when performed with a 130° main nail angle.
Collapse
Affiliation(s)
- Ying Wang
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Jian-Xiong Ma
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Hao-Hao Bai
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Bin Lu
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Lei Sun
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Hong-Zhen Jin
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| | - Xin-Long Ma
- Orthopaedics Institute, Tianjin Hospital, Tianjin University, Tianjin 300050, China
| |
Collapse
|
21
|
Klontzas ME, Koltsakis E, Kalarakis G, Trpkov K, Papathomas T, Karantanas AH, Tzortzakakis A. Machine Learning Integrating 99mTc Sestamibi SPECT/CT and Radiomics Data Achieves Optimal Characterization of Renal Oncocytic Tumors. Cancers (Basel) 2023; 15:3553. [PMID: 37509214 PMCID: PMC10377512 DOI: 10.3390/cancers15143553] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 07/04/2023] [Accepted: 07/06/2023] [Indexed: 07/30/2023] Open
Abstract
The increasing evidence of oncocytic renal tumors positive in 99mTc Sestamibi Single Photon Emission Tomography/Computed Tomography (SPECT/CT) examination calls for the development of diagnostic tools to differentiate these tumors from more aggressive forms. This study combined radiomics analysis with the uptake of 99mTc Sestamibi on SPECT/CT to differentiate benign renal oncocytic neoplasms from renal cell carcinoma. A total of 57 renal tumors were prospectively collected. Histopathological analysis and radiomics data extraction were performed. XGBoost classifiers were trained using the radiomics features alone and combined with the results from the visual evaluation of 99mTc Sestamibi SPECT/CT examination. The combined SPECT/radiomics model achieved higher accuracy (95%) with an area under the curve (AUC) of 98.3% (95% CI 93.7-100%) than the radiomics-only model (71.67%) with an AUC of 75% (95% CI 49.7-100%) and visual evaluation of 99mTc Sestamibi SPECT/CT alone (90.8%) with an AUC of 90.8% (95%CI 82.5-99.1%). The positive predictive values of SPECT/radiomics, radiomics-only, and 99mTc Sestamibi SPECT/CT-only models were 100%, 85.71%, and 85%, respectively, whereas the negative predictive values were 85.71%, 55.56%, and 94.6%, respectively. Feature importance analysis revealed that 99mTc Sestamibi uptake was the most influential attribute in the combined model. This study highlights the potential of combining radiomics analysis with 99mTc Sestamibi SPECT/CT to improve the preoperative characterization of benign renal oncocytic neoplasms. The proposed SPECT/radiomics classifier outperformed the visual evaluation of 99mTc Sestamibii SPECT/CT and the radiomics-only model, demonstrating that the integration of 99mTc Sestamibi SPECT/CT and radiomics data provides improved diagnostic performance, with minimal false positive and false negative results.
Collapse
Affiliation(s)
- Michail E Klontzas
- Department of Medical Imaging, University Hospital of Heraklion, Heraklion 71110, Greece
- Computational BioMedicine Laboratory, Institute of Computer Science, Foundation for Research and Technology (FORTH), Heraklion 70013, Greece
- Department of Radiology, School of Medicine, University of Crete, Voutes Campus, Heraklion 71110, Greece
| | - Emmanouil Koltsakis
- Department of Diagnostic Radiology, Karolinska University Hospital, Stockholm 17177, Sweden
| | - Georgios Kalarakis
- Department of Diagnostic Radiology, Karolinska University Hospital, Stockholm 17177, Sweden
- Division of Radiology, Department for Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm 14152, Sweden
| | - Kiril Trpkov
- Alberta Precision Labs, Department of Pathology and Laboratory Medicine, Cumming School of Medicine, University of Calgary, Calgary, AB T2L 2K5, Canada
| | - Thomas Papathomas
- Institute of Metabolism and Systems Research, University of Birmingham, Birmingham B15 2TT, UK
- Department of Clinical Pathology, Vestre Viken Hospital Trust, Drammen 3004, Norway
| | - Apostolos H Karantanas
- Department of Medical Imaging, University Hospital of Heraklion, Heraklion 71110, Greece
- Computational BioMedicine Laboratory, Institute of Computer Science, Foundation for Research and Technology (FORTH), Heraklion 70013, Greece
- Department of Radiology, School of Medicine, University of Crete, Voutes Campus, Heraklion 71110, Greece
| | - Antonios Tzortzakakis
- Division of Radiology, Department for Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm 14152, Sweden
- Medical Radiation Physics and Nuclear Medicine, Section for Nuclear Medicine, Karolinska University Hospital, Huddinge, Stockholm 14186, Sweden
| |
Collapse
|
22
|
Moissenet F, Beauseroy V, Gasparutto X, Armand S, Hannouche D, Dumas R. Estimation of two wear factors for total hip arthroplasty: A simulation study based on musculoskeletal modelling. Clin Biomech (Bristol, Avon) 2023; 107:106035. [PMID: 37413813 DOI: 10.1016/j.clinbiomech.2023.106035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 05/31/2023] [Accepted: 06/26/2023] [Indexed: 07/08/2023]
Abstract
BACKGROUND Primary causes of surgical revision after total hip arthroplasty are polyethylene wear and implant loosening. These factors are particularly related to joint friction and thus patients' physical activity. Assessing implant wear over time according to patients' morphology and physical activity level is key to improve follow-up and patients' quality of life. METHODS An approach initially proposed for tibiofemoral prosthetic wear estimation was adapted to compute two wear factors (force-velocity, directional wear intensity) using a musculoskeletal model. It was applied on 17 participants with total hip arthroplasty to compute joint angular velocity, contact force, sliding velocity, and wear factors during common daily living activities. FINDINGS Differences were observed between gait, sitting down, and standing up tasks. An incremental increase of both global wear factors (time-integral) was observed during gait from slow to fast speeds (p ≤ 0.01). Interestingly, these two wear factors did not result in same trend for sitting down and standing up tasks. Compared to gait, one cycle of sitting down or standing up tends to induce higher friction-related wear but lower cross-shear-related wear. Depending on the wear factor, significant differences can be found between sitting down and gait at slow speed (p ≤ 0.05), and between sitting down (p ≤ 0.05) or standing up (p ≤ 0.05) and gait at fast speed. Furthermore, depending on the activity, wear can be fostered by joint contact force and/or sliding velocity. INTERPRETATION This study demonstrated the potential of wear estimation to highlight activities inducing a higher risk of implant wear after total hip arthroplasty from motion capture data.
Collapse
Affiliation(s)
- Florent Moissenet
- Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland; Biomechanics Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland.
| | - Victor Beauseroy
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR T_9406, F-69622 Lyon, France
| | - Xavier Gasparutto
- Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland
| | - Stéphane Armand
- Kinesiology Laboratory, Geneva University Hospitals and University of Geneva, Geneva, Switzerland
| | - Didier Hannouche
- Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Raphaël Dumas
- Univ Lyon, Univ Gustave Eiffel, Univ Claude Bernard Lyon 1, LBMC UMR T_9406, F-69622 Lyon, France
| |
Collapse
|
23
|
Voljc T, Schintler M, Vasilyeva A, Kamolz LP, Buerger H. Simultaneous Free Fibula and Anterolateral Thigh Flap in Lower Extremity Reconstruction Following Osteomyelitis in a Trauma Patient: A Case Report. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:1206. [PMID: 37512018 PMCID: PMC10384821 DOI: 10.3390/medicina59071206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 06/12/2023] [Accepted: 06/21/2023] [Indexed: 07/30/2023]
Abstract
This case report focuses on a 17-year-old polytrauma patient who suffered a septic wound infection after an open reduction and internal fixation (ORIF) and soft tissue reconstruction with a pedicled flap, which led to a substantial bone and soft tissue defect of the lower leg. After thorough antibiotic treatment and after ensuring a non-septic wound, the defect was reconstructed using a contralateral free fibula flap designed as a flow through flap in a double loop manner to accommodate two fibular fragments and an ipsilateral ALT flap. Early weight bearing was initiated 11 days after the free flap transfer under external fixation, with full weight bearing achieved in 36 days with external fixation. After the removal of external fixation, full weight bearing was able to be reinitiated after 13 days, leading to the patient's return to normal activity 6 months after the bony reconstruction. This case presents an innovative approach to treating a complex defect, with the final decision on using two separate free flaps instead of a single osteofasciocutaneous free flap resulting in a good bony reconstruction and soft tissue coverage, and with the use of external fixation enabling early rehabilitation.
Collapse
Affiliation(s)
- Tadej Voljc
- Division of Plastic, Aesthetic and Reconstructive Surgery, Department of Surgery, University Hospital Graz, 8036 Graz, Austria
| | - Michael Schintler
- Division of Plastic, Aesthetic and Reconstructive Surgery, Department of Surgery, University Hospital Graz, 8036 Graz, Austria
| | - Anna Vasilyeva
- Division of Plastic, Aesthetic and Reconstructive Surgery, Department of Surgery, University Hospital Graz, 8036 Graz, Austria
| | - Lars-Peter Kamolz
- Division of Plastic, Aesthetic and Reconstructive Surgery, Department of Surgery, University Hospital Graz, 8036 Graz, Austria
| | - Heinz Buerger
- Division of Plastic, Aesthetic and Reconstructive Surgery, Department of Surgery, University Hospital Graz, 8036 Graz, Austria
- Division of Hand and Microsurgery, Private Hospital Maria Hilf, 9020 Klagenfurt am Woerthersee, Austria
| |
Collapse
|
24
|
Fujishita H, Ikuta Y, Maeda N, Komiya M, Morikawa M, Arima S, Sakamitsu T, Obayashi H, Fukuhara K, Ushio K, Adachi N. Effects of Rearfoot Eversion on Foot Plantar Pressure and Spatiotemporal Gait Parameters in Adolescent Athletes. Healthcare (Basel) 2023; 11:1842. [PMID: 37444676 DOI: 10.3390/healthcare11131842] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 05/25/2023] [Accepted: 06/23/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND Foot malalignment can augment the risk of lower-extremity injuries and lead to musculoskeletal disorders. This study aimed to clarify the contribution of rearfoot alignment to plantar pressure distribution and spatiotemporal parameters during gait in healthy adolescent athletes. METHODS This retrospective study included 39 adolescent athletes who were divided into the rearfoot eversion and control groups according to a leg heel angle of 7°. A total of 78 legs were analyzed (45 and 33 legs in the rearfoot eversion [women, 53.3%] and control groups [women, 48.5%], respectively). Gait was assessed using an in-shoe plantar pressure measuring system and a wearable inertial sensor. RESULTS The foot plantar pressure distribution in the hallux was higher in the rearfoot eversion group than that in the control group (p = 0.034). Spatiotemporal parameters showed that the foot pitch angle at heel strike was significantly larger in the rearfoot eversion group than that in the control group (24.5° vs. 21.7°; p = 0.015). Total sagittal range of motion of the ankle during the stance phase of gait was significantly larger in the rearfoot eversion group than that in the control group (102.5 ± 7.1° vs. 95.6 ± 15.8°; p = 0.020). Logistic regression analysis revealed that plantar pressure at the hallux and medial heel and foot pitch angle at heel strike were significantly associated with rearfoot eversion. CONCLUSIONS Our findings suggest that rearfoot eversion affects the gait patterns of adolescent athletes. Notably, leg heel angle assessment, which is a simple and quick procedure, should be considered as an alternative screening tool for estimating plantar pressure and spatiotemporal gait parameters to prevent sports-related and overuse injuries in adolescent athletes.
Collapse
Affiliation(s)
- Hironori Fujishita
- Department of Sports Medical Center, Hiroshima University Hospital, Hiroshima 734-8551, Japan
| | - Yasunari Ikuta
- Department of Sports Medical Center, Hiroshima University Hospital, Hiroshima 734-8551, Japan
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8551, Japan
| | - Noriaki Maeda
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan
| | - Makoto Komiya
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan
| | - Masanori Morikawa
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan
| | - Satoshi Arima
- Department of Sports Rehabilitation, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8553, Japan
| | - Tetsuhiko Sakamitsu
- Department of Sports Medical Center, Hiroshima University Hospital, Hiroshima 734-8551, Japan
| | - Hiromune Obayashi
- Department of Sports Medical Center, Hiroshima University Hospital, Hiroshima 734-8551, Japan
| | - Kouki Fukuhara
- Department of Sports Medical Center, Hiroshima University Hospital, Hiroshima 734-8551, Japan
| | - Kai Ushio
- Department of Rehabilitation Medicine, Hiroshima University Hospital, Hiroshima 734-8551, Japan
| | - Nobuo Adachi
- Department of Orthopaedic Surgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima 734-8551, Japan
| |
Collapse
|
25
|
Kowal M, Morgiel E, Winiarski S, Gieysztor E, Madej M, Sebastian A, Madziarski M, Wedel N, Proc K, Madziarska K, Wiland P, Paprocka-Borowicz M. Effect of COVID-19 on Musculoskeletal Performance in Gait and the Timed-Up and Go Test. J Clin Med 2023; 12:4184. [PMID: 37445219 DOI: 10.3390/jcm12134184] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Revised: 06/19/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023] Open
Abstract
INTRODUCTION The total number of confirmed cases of COVID-19 caused by the SARS-CoV-2 virus infection is over 621 million in the world. In approximately 63% of cases, the patient still experiences persistent symptoms 30 days after the onset of symptoms or hospitalisation, and 45.9% of patients have experienced or will experience symptoms for at least three months. Despite the prevalence of chronic symptoms and pathological changes that may affect gait and functional mobility in people with a history of COVID-19, there are few publications investigating the impact of these abnormalities. This study aims to determine the long-term effects of COVID-19 on gait and the Timed-Up and Go Task. MATERIAL AND METHODS A total of 30 individuals took part in the experiment. The subjects in the study group were infected with the COVID-19 virus and required hospital treatment. Prior to the study, the subjects had no chronic diseases or other conditions affecting the musculoskeletal system. The non-infected by COVID-19 group was a healthy population with no history of COVID-19 disease. The study used the inertial system wireless motion analysis system based on 15 inertial sensors (inertial measurement units, IMUs). IMU sensors were placed on the following body segments: head, sternum, middle and lower spine, shoulder, arm, forearm, hand, shank, for the left and right limb. Movement task reports generated from the recording were created using myoRESEARCH 3.10. The subjects in the study group were asked to perform a movement task test-the Timed-Up and Go Test (TUG): sit-to-stand, walk (3 m) without change in direction, walk termination, and stand-to-sit. RESULTS It took 46% longer for those infected by COVID-19 (participants) to complete the entire movement task compared to those in the not-infected by COVID-19 group. Sit-to-Stand Time [s] was greater in the infected by COVID-19 group and was 2.1 ± 0.7. Mean Walking Speed [m/s] was lower than in the not-infected by COVID-19 group and was 0.26 ± 0.07. Walking cadence [steps/min] was lower and was 21.2 ± 1.2. Infected by COVID-19 participants achieved a smaller anterior pelvic tilt angle (p < 0.001) and a smaller hip flexion angle (p = 0.025), with an increase in knee (p < 0.001) and ankle (p < 0.001) flexion angles. CONCLUSIONS Individuals in the infected by COVID-19 group present changes in the ranges of motion and the time to complete the TUG task, despite the fact that at least eight weeks passed after hospital discharge.
Collapse
Affiliation(s)
- Mateusz Kowal
- Department of Physiotherapy, Wroclaw Medical University, T. Chałubińskiego 3, 50-556 Wrocław, Poland
| | - Ewa Morgiel
- Department of Rheumatology and Internal Medicine, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Sławomir Winiarski
- Biomechanics Department, Wroclaw University of Health and Sport Sciences, Paderewskiego 35, 51-612 Wrocław, Poland
| | - Ewa Gieysztor
- Department of Physiotherapy, Wroclaw Medical University, T. Chałubińskiego 3, 50-556 Wrocław, Poland
| | - Marta Madej
- Department of Rheumatology and Internal Medicine, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Agata Sebastian
- Department of Rheumatology and Internal Medicine, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Marcin Madziarski
- Department of Rheumatology and Internal Medicine, University Hospital, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Nicole Wedel
- Department of Medicine, Albert Einstein College of Medicine, 1300 Morris Park Ave., New York, NY 10461, USA
| | - Krzysztof Proc
- Department of Rheumatology and Internal Medicine, University Hospital, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Katarzyna Madziarska
- Clinical Department of Nephrology and Transplantation Medicine, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | - Piotr Wiland
- Department of Rheumatology and Internal Medicine, Wroclaw Medical University, Borowska Street 213, 50-556 Wroclaw, Poland
| | | |
Collapse
|
26
|
López-Hualda A, Arruti-Pérez E, Bebea-Zamorano FN, Sosa-Reina MD, Villafañe JH, Martínez-Martin J. Morbidity and Mortality Analysis in the Treatment of Intertrochanteric Hip Fracture with Two Fixation Systems: Dynamic Hip Screw (DHS) or Trochanteric Fixation Nail Advance (TFNA). Geriatrics (Basel) 2023; 8:66. [PMID: 37367098 DOI: 10.3390/geriatrics8030066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 05/31/2023] [Accepted: 06/06/2023] [Indexed: 06/28/2023] Open
Abstract
BACKGROUND The aim of this study was to compare the clinical outcomes, complications, and mortality of patients with intertrochanteric hip fracture treated with dynamic hip screw (DHS) vs. trochanteric fixation nail advance (TFNA). METHODS We evaluated 152 patients with intertrochanteric fractures concerning age, sex, comorbidity, Charlson Index, preoperative gait, OTA/AO classification, time from fracture to surgery, blood loss, amount of blood replacement, changes in gait, full weight-bearing at hospital discharge, complications, and mortality. The final indicators encompassed the adverse effects linked to implants, postoperative complications, clinical healing or bone healing duration, and functional score. RESULTS The study included a total of 152 patients, out of which 78 (51%) received DHS treatment and 74 (49%) received TFNA treatment. The results of this study show that the TFNA group demonstrated superiority (p < 0.001). However, it should be noted that the TFNA group had a higher frequency of the most unstable fractures (AO 31 A3, p < 0.005). Full weight-bearing at discharge also decreased in patients with more unstable fractures (p = 0.005) and severe dementia (p = 0.027). Mortality was higher in the DHS group; however, a longer time from diagnosis to surgery was also observed in this group (p < 0.005). CONCLUSIONS The TFNA group has shown a higher success rate in achieving full weight-bearing at hospital discharge when treating trochanteric hip fractures. This makes it the preferred choice for treating unstable fractures in this region of the hip. Additionally, it is important to note that a longer time to surgery is associated with increased mortality in patients with hip fractures.
Collapse
Affiliation(s)
- Alvaro López-Hualda
- Orthopedic Surgery and Traumatology Service, Hospital Universitario Fundación Alcorcon, 28922 Alcorcón, Spain
| | - Elsa Arruti-Pérez
- Orthopedic Surgery and Traumatology Service, Hospital Universitario Fundación Alcorcon, 28922 Alcorcón, Spain
| | - Fátima N Bebea-Zamorano
- Orthopedic Surgery and Traumatology Service, Hospital Universitario Fundación Alcorcon, 28922 Alcorcón, Spain
| | - María Dolores Sosa-Reina
- Department of Physiotherapy, Faculty of Sports Sciences, Universidad Europea de Madrid, Calle Tajo s/n, 28670 Villaviciosa de Odón, Spain
- Musculoskeletal Pain and Motor Control Research Group, Faculty of Sport Sciences, Universidad Europea de Madrid, 28670 Villaviciosa de Odón, Spain
| | | | - Javier Martínez-Martin
- Orthopedic Surgery and Traumatology Service, Hospital Universitario Fundación Alcorcon, 28922 Alcorcón, Spain
| |
Collapse
|
27
|
Hou Y, Deng B, Wang S, Ma Y, Long X, Wang F, Qin C, Liang C, Yao S. High-Strength, High-Water-Retention Hemicellulose-Based Hydrogel and Its Application in Urea Slow Release. Int J Mol Sci 2023; 24:ijms24119208. [PMID: 37298162 DOI: 10.3390/ijms24119208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/19/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023] Open
Abstract
The use of fertilizer is closely related to crop growth and environmental protection in agricultural production. It is of great significance to develop environmentally friendly and biodegradable bio-based slow-release fertilizers. In this work, porous hemicellulose-based hydrogels were created, which had excellent mechanical properties, water retention properties (the water retention ratio in soil was 93.8% after 5 d), antioxidant properties (76.76%), and UV resistance (92.2%). This improves the efficiency and potential of its application in soil. In addition, electrostatic interaction and coating with sodium alginate produced a stable core-shell structure. The slow release of urea was realized. The cumulative release ratio of urea after 12 h was 27.42% and 11.38%, and the release kinetic constants were 0.0973 and 0.0288, in aqueous solution and soil, respectively. The sustained release results demonstrated that urea diffusion in aqueous solution followed the Korsmeyer-Peppas model, indicating the Fick diffusion mechanism, whereas diffusion in soil adhered to the Higuchi model. The outcomes show that urea release ratio may be successfully slowed down by hemicellulose hydrogels with high water retention ability. This provides a new method for the application of lignocellulosic biomass in agricultural slow-release fertilizer.
Collapse
Affiliation(s)
- Yajun Hou
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Baojuan Deng
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Shanshan Wang
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Yun Ma
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Xing Long
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Fei Wang
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Chengrong Qin
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Chen Liang
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| | - Shuangquan Yao
- Guangxi Key Laboratory of Clean Pulp & Papermaking and Pollution Control, School of Light Industrial and Food Engineering, Guangxi University, Nanning 530004, China
| |
Collapse
|
28
|
Malaina I, Gonzalez-Melero L, Martínez L, Salvador A, Sanchez-Diez A, Asumendi A, Margareto J, Carrasco-Pujante J, Legarreta L, García MA, Pérez-Pinilla MB, Izu R, Martínez de la Fuente I, Igartua M, Alonso S, Hernandez RM, Boyano MD. Computational and Experimental Evaluation of the Immune Response of Neoantigens for Personalized Vaccine Design. Int J Mol Sci 2023; 24:9024. [PMID: 37240369 PMCID: PMC10219310 DOI: 10.3390/ijms24109024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Revised: 05/16/2023] [Accepted: 05/17/2023] [Indexed: 05/28/2023] Open
Abstract
In the last few years, the importance of neoantigens in the development of personalized antitumor vaccines has increased remarkably. In order to study whether bioinformatic tools are effective in detecting neoantigens that generate an immune response, DNA samples from patients with cutaneous melanoma in different stages were obtained, resulting in a total of 6048 potential neoantigens gathered. Thereafter, the immunological responses generated by some of those neoantigens ex vivo were tested, using a vaccine designed by a new optimization approach and encapsulated in nanoparticles. Our bioinformatic analysis indicated that no differences were found between the number of neoantigens and that of non-mutated sequences detected as potential binders by IEDB tools. However, those tools were able to highlight neoantigens over non-mutated peptides in HLA-II recognition (p-value 0.03). However, neither HLA-I binding affinity (p-value 0.08) nor Class I immunogenicity values (p-value 0.96) indicated significant differences for the latter parameters. Subsequently, the new vaccine, using aggregative functions and combinatorial optimization, was designed. The six best neoantigens were selected and formulated into two nanoparticles, with which the immune response ex vivo was evaluated, demonstrating a specific activation of the immune response. This study reinforces the use of bioinformatic tools in vaccine development, as their usefulness is proven both in silico and ex vivo.
Collapse
Affiliation(s)
- Iker Malaina
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
| | - Lorena Gonzalez-Melero
- NanoBioCel Research Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), 01006 Vitoria-Gasteiz, Spain (R.M.H.)
- Bioaraba, NanoBioCel Research Group, 01009 Vitoria-Gasteiz, Spain
| | - Luis Martínez
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
- Luis Martínez, Basque Center for Applied Mathematics BCAM, 48009 Bilbao, Spain
| | - Aiala Salvador
- NanoBioCel Research Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), 01006 Vitoria-Gasteiz, Spain (R.M.H.)
- Bioaraba, NanoBioCel Research Group, 01009 Vitoria-Gasteiz, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN). Institute of Health Carlos III, 28029 Madrid, Spain
| | - Ana Sanchez-Diez
- Department of Dermatology, Basurto University Hospital, 48013 Bilbao, Spain
- Biocruces Bizkaia Health Research Institute, 48903 Barakaldo, Spain (M.D.B.)
| | - Aintzane Asumendi
- Biocruces Bizkaia Health Research Institute, 48903 Barakaldo, Spain (M.D.B.)
- Department of Cell Biology and Histology, Faculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
| | - Javier Margareto
- Technological Services Division, Health and Quality of Life, TECNALIA, 01510 Miñano, Spain
| | - Jose Carrasco-Pujante
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
- Luis Martínez, Basque Center for Applied Mathematics BCAM, 48009 Bilbao, Spain
| | - Leire Legarreta
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
- Luis Martínez, Basque Center for Applied Mathematics BCAM, 48009 Bilbao, Spain
| | - María Asunción García
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
- Luis Martínez, Basque Center for Applied Mathematics BCAM, 48009 Bilbao, Spain
| | - Martín Blas Pérez-Pinilla
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
- Luis Martínez, Basque Center for Applied Mathematics BCAM, 48009 Bilbao, Spain
| | - Rosa Izu
- Department of Dermatology, Basurto University Hospital, 48013 Bilbao, Spain
- Biocruces Bizkaia Health Research Institute, 48903 Barakaldo, Spain (M.D.B.)
| | - Ildefonso Martínez de la Fuente
- Department of Mathematics, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
- Luis Martínez, Basque Center for Applied Mathematics BCAM, 48009 Bilbao, Spain
- CEBAS-CSIC Institute, Department of Nutrition, 30100 Murcia, Spain
| | - Manoli Igartua
- NanoBioCel Research Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), 01006 Vitoria-Gasteiz, Spain (R.M.H.)
- Bioaraba, NanoBioCel Research Group, 01009 Vitoria-Gasteiz, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN). Institute of Health Carlos III, 28029 Madrid, Spain
| | - Santos Alonso
- Department of Genetics, Physical Anthropology and Animal Physiology, Faculty of Science and Technology, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
| | - Rosa Maria Hernandez
- NanoBioCel Research Group, Laboratory of Pharmaceutics, School of Pharmacy, University of the Basque Country (UPV/EHU), 01006 Vitoria-Gasteiz, Spain (R.M.H.)
- Bioaraba, NanoBioCel Research Group, 01009 Vitoria-Gasteiz, Spain
- Biomedical Research Networking Centre in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN). Institute of Health Carlos III, 28029 Madrid, Spain
| | - María Dolores Boyano
- Biocruces Bizkaia Health Research Institute, 48903 Barakaldo, Spain (M.D.B.)
- Department of Cell Biology and Histology, Faculty of Medicine and Nursing, University of the Basque Country (UPV/EHU), 48940 Leioa, Spain
| |
Collapse
|
29
|
Diaz-Saez MC, Gil-Martínez A, Gadotti IC, Navarro-Fernández G, Gil-Castillo J, Beltran-Alacreu H. Reliability and Responsiveness of a Novel Device to Evaluate Tongue Force. Life (Basel) 2023; 13:life13051192. [PMID: 37240837 DOI: 10.3390/life13051192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/21/2023] [Accepted: 05/11/2023] [Indexed: 05/28/2023] Open
Abstract
BACKGROUND Measurements of tongue force are important in clinical practice during both the diagnostic process and rehabilitation progress. It has been shown that patients with chronic temporomandibular disorders have less tongue strength than asymptomatic subjects. Currently, there are few devices to measure tongue force on the market, with different limitations. That is why a new device has been developed to overcome them. The objectives of the study were to determine the intra- and inter-rater reliability and the responsiveness of a new low-cost device to evaluate tongue force in an asymptomatic population. MATERIALS AND METHODS Two examiners assessed the maximal tongue force in 26 asymptomatic subjects using a developed prototype of an Arduino device. Each examiner performed a total of eight measurements of tongue force in each subject. Each tongue direction was measured twice (elevation, depression, right lateralization, and left lateralization) in order to test the intrarater reliability. RESULTS The intrarater reliability using the new device was excellent for the measurements of the tongue force for up (ICC > 0.94), down (ICC > 0.93) and right (ICC > 0.92) movements, and good for the left movement (ICC > 0.82). The SEM and MDC values were below 0.98 and 2.30, respectively, for the intrarater reliability analysis. Regarding the inter-rater reliability, the ICC was excellent for measuring the tongue up movements (ICC = 0.94), and good for all the others (down ICC = 0.83; right ICC = 0.87; and left ICC = 0.81). The SEM and MDC values were below 1.29 and 3.01, respectively, for the inter-rater reliability. CONCLUSIONS This study showed a good-to-excellent intra- and inter-reliability and good responsiveness in the new device to measure different directions of tongue force in an asymptomatic population. This could be a new, more accessible tool to consider and add to the assessment and treatment of different clinical conditions in which a deficit in tongue force could be found.
Collapse
Affiliation(s)
- Marta Carlota Diaz-Saez
- Physiotherapy Department, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, C/La Salle, 28023 Madrid, Spain
- CranioSPain Research Group, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, C/La Salle, 28023 Madrid, Spain
- Programa de Doctorado en Medicina y Cirugía, Universidad Autónoma de Madrid, C/Francisco Tomás y Valiente 5, 28049 Madrid, Spain
| | - Alfonso Gil-Martínez
- Physiotherapy Department, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, C/La Salle, 28023 Madrid, Spain
- CranioSPain Research Group, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, C/La Salle, 28023 Madrid, Spain
- Hospital Universitario La Paz-Carlos III. Institute for Health Research (IdiPaz), Paseo la Castellana, 261, 28046 Madrid, Spain
| | - Inae Caroline Gadotti
- Department of Physical Therapy, Nicole Wertheim College of Nursing and Health Sciences, Florida International University, 11865 SW 26th St Suite H3, Miami, FL 33199, USA
| | - Gonzalo Navarro-Fernández
- CranioSPain Research Group, Centro Superior de Estudios Universitarios La Salle, Universidad Autónoma de Madrid, C/La Salle, 28023 Madrid, Spain
| | - Javier Gil-Castillo
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Av. Doctor Arce, 37, 28002 Madrid, Spain
| | - Hector Beltran-Alacreu
- Toledo Physiotherapy Research Group (GIFTO), Faculty of Physical Therapy and Nursing, Universidad de Castilla-La Mancha, Avenida de Carlos III s/n, 45071 Toledo, Spain
| |
Collapse
|
30
|
Zamudio-Ceja RB, Garcia-Contreras R, Chavez-Granados PA, Aranda-Herrera B, Alvarado-Garnica H, Jurado CA, Fischer NG. Decellularized Scaffolds of Nopal ( Opuntia Ficus-indica) for Bioengineering in Regenerative Dentistry. J Funct Biomater 2023; 14:jfb14050252. [PMID: 37233362 DOI: 10.3390/jfb14050252] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 04/23/2023] [Accepted: 04/27/2023] [Indexed: 05/27/2023] Open
Abstract
Opuntia Ficus-indica, or nopal, is traditionally used for its medicinal properties in Mexico. This study aims to decellularize and characterize nopal (Opuntia Ficus-indica) scaffolds, assess their degradation and the proliferation of hDPSC, and determine potential pro-inflammatory effects by assessing the expression of cyclooxygenase 1 and 2 (COX-1 and 2). The scaffolds were decellularized using a 0.5% sodium dodecyl sulfate (SDS) solution and confirmed by color, optical microscopy, and SEM. The degradation rates and mechanical properties of the scaffolds were determined by weight and solution absorbances using trypsin and PBS and tensile strength testing. Human dental pulp stem cells (hDPSCs) primary cells were used for scaffold-cell interaction and proliferation assays, as well as an MTT assay to determine proliferation. Proinflammatory protein expression of COX-I and -II was discovered by Western blot assay, and the cultures were induced into a pro-inflammatory state with interleukin 1-β. The nopal scaffolds exhibited a porous structure with an average pore size of 252 ± 77 μm. The decellularized scaffolds showed a 57% reduction in weight loss during hydrolytic degradation and a 70% reduction during enzymatic degradation. There was no difference in tensile strengths between native and decellularized scaffolds (12.5 ± 1 and 11.8 ± 0.5 MPa). Furthermore, hDPSCs showed a significant increase in cell viability of 95% and 106% at 168 h for native and decellularized scaffolds, respectively. The combination of the scaffold and hDPSCs did not cause an increase in the expression of COX-1 and COX-2 proteins. However, when the combination was exposed to IL-1β, there was an increase in the expression of COX-2. This study demonstrates the potential application of nopal scaffolds in tissue engineering and regenerative medicine or dentistry, owing to their structural characteristics, degradation properties, mechanical properties, ability to induce cell proliferation, and lack of enhancement of pro-inflammatory cytokines.
Collapse
Affiliation(s)
- Ruth Betsabe Zamudio-Ceja
- Interdisciplinary Research Laboratory, Nanostructures, and Biomaterials Area, National School of Higher Studies (ENES) Leon, National Autonomous University of Mexico (UNAM), Leon 37684, Gto, Mexico
| | - Rene Garcia-Contreras
- Interdisciplinary Research Laboratory, Nanostructures, and Biomaterials Area, National School of Higher Studies (ENES) Leon, National Autonomous University of Mexico (UNAM), Leon 37684, Gto, Mexico
| | - Patricia Alejandra Chavez-Granados
- Interdisciplinary Research Laboratory, Nanostructures, and Biomaterials Area, National School of Higher Studies (ENES) Leon, National Autonomous University of Mexico (UNAM), Leon 37684, Gto, Mexico
| | - Benjamin Aranda-Herrera
- Interdisciplinary Research Laboratory, Nanostructures, and Biomaterials Area, National School of Higher Studies (ENES) Leon, National Autonomous University of Mexico (UNAM), Leon 37684, Gto, Mexico
| | - Hugo Alvarado-Garnica
- Interdisciplinary Research Laboratory, Nanostructures, and Biomaterials Area, National School of Higher Studies (ENES) Leon, National Autonomous University of Mexico (UNAM), Leon 37684, Gto, Mexico
| | - Carlos A Jurado
- Department of Prosthodontics, The University of Iowa College of Dentistry and Dental Clinics, Iowa City, IA 52242, USA
| | - Nicholas G Fischer
- Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, Minneapolis, MN 55455, USA
| |
Collapse
|
31
|
Salaha ZFM, Ammarullah MI, Abdullah NNAA, Aziz AUA, Gan HS, Abdullah AH, Abdul Kadir MR, Ramlee MH. Biomechanical Effects of the Porous Structure of Gyroid and Voronoi Hip Implants: A Finite Element Analysis Using an Experimentally Validated Model. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16093298. [PMID: 37176180 PMCID: PMC10179376 DOI: 10.3390/ma16093298] [Citation(s) in RCA: 41] [Impact Index Per Article: 20.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Revised: 04/12/2023] [Accepted: 04/20/2023] [Indexed: 05/15/2023]
Abstract
Total hip arthroplasty (THA) is most likely one of the most successful surgical procedures in medicine. It is estimated that three in four patients live beyond the first post-operative year, so appropriate surgery is needed to alleviate an otherwise long-standing suboptimal functional level. However, research has shown that during a complete THA procedure, a solid hip implant inserted in the femur can damage the main arterial supply of the cortex and damage the medullary space, leading to cortical bone resorption. Therefore, this study aimed to design a porous hip implant with a focus on providing more space for better osteointegration, improving the medullary revascularisation and blood circulation of patients. Based on a review of the literature, a lightweight implant design was developed by applying topology optimisation and changing the materials of the implant. Gyroid and Voronoi lattice structures and a solid hip implant (as a control) were designed. In total, three designs of hip implants were constructed by using SolidWorks and nTopology software version 2.31. Point loads were applied at the x, y and z-axis to imitate the stance phase condition. The forces represented were x = 320 N, y = -170 N, and z = -2850 N. The materials that were used in this study were titanium alloys. All of the designs were then simulated by using Marc Mentat software version 2020 (MSC Software Corporation, Munich, Germany) via a finite element method. Analysis of the study on topology optimisation demonstrated that the Voronoi lattice structure yielded the lowest von Mises stress and displacement values, at 313.96 MPa and 1.50 mm, respectively, with titanium alloys as the materials. The results also indicate that porous hip implants have the potential to be implemented for hip implant replacement, whereby the mechanical integrity is still preserved. This result will not only help orthopaedic surgeons to justify the design choices, but could also provide new insights for future studies in biomechanics.
Collapse
Affiliation(s)
- Zatul Faqihah Mohd Salaha
- Bone Biomechanics Laboratory (BBL), Department of Biomedical Engineering and Health Sciences, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
| | - Muhammad Imam Ammarullah
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Undip Biomechanics Engineering & Research Centre (UBM-ERC), Universitas Diponegoro, Semarang 50275, Central Java, Indonesia
| | - Nik Nur Ain Azrin Abdullah
- Bone Biomechanics Laboratory (BBL), Department of Biomedical Engineering and Health Sciences, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
| | - Aishah Umairah Abd Aziz
- Bone Biomechanics Laboratory (BBL), Department of Biomedical Engineering and Health Sciences, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
| | - Hong-Seng Gan
- School of AI and Advanced Computing, XJTLU Entrepreneur College (Taicang), Xi'an Jiaotong-Liverpool University, Suzhou 215400, China
| | - Abdul Halim Abdullah
- School of Mechanical Engineering, College of Engineering, Universiti Teknologi MARA, Shah Alam 40450, Selangor, Malaysia
| | - Mohammed Rafiq Abdul Kadir
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
- Medical Devices and Technology Centre (MEDiTEC), Institute of Human Centered Engineering (iHumEn), Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
| | - Muhammad Hanif Ramlee
- Bone Biomechanics Laboratory (BBL), Department of Biomedical Engineering and Health Sciences, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
- Bioinspired Devices and Tissue Engineering (BIOINSPIRA) Research Group, Universiti Teknologi Malaysia, Johor Bahru 81310, Johor, Malaysia
| |
Collapse
|
32
|
Elahi A, Duncan W, Li KC, Waddell JN, Coates D. Comparison of Low and High Temperature Sintering for Processing of Bovine Bone as Block Grafts for Oral Use: A Biological and Mechanical In Vitro Study. Bioengineering (Basel) 2023; 10:bioengineering10040473. [PMID: 37106660 PMCID: PMC10136185 DOI: 10.3390/bioengineering10040473] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Revised: 04/07/2023] [Accepted: 04/07/2023] [Indexed: 04/29/2023] Open
Abstract
Large oral bone defects require grafting of bone blocks rather than granules to give physically robust, biocompatible and osteoconductive regeneration. Bovine bone is widely accepted as a source of clinically appropriate xenograft material. However, the manufacturing process often results in both reduced mechanical strength and biological compatibility. The aim of this study was to assess bovine bone blocks at different sintering temperatures and measure the effects on mechanical properties and biocompatibility. Bone blocks were divided into four groups; Group 1: Control (Untreated); Group 2: Initial boil for 6 h; Group 3: Boil 6 h followed by sintering at 550 °C for 6 h; Group 4: Boil 6 h followed by sintering at 1100 °C for 6 h. Samples were assessed for their purity, crystallinity, mechanical strength, surface morphology, chemical composition, biocompatibility and clinical handling properties. Statistical analysis was performed using one-way ANOVA and post-hoc Tukey's tests for normally distributed and Friedman test for abnormally distributed quantitative data from compression tests and PrestoBlue™ metabolic activity tests. The threshold for statistical significance was set at p < 0.05. The results showed that higher temperature sintering (Group 4) removed all organic material (0.02% organic components and 0.02% residual organic components remained) and increased crystallinity (95.33%) compared to Groups 1-3. All test groups (Group 2-4) showed decreased mechanical strength (MPa: 4.21 ± 1.97, 3.07 ± 1.21, 5.14 ± 1.86, respectively) compared with raw bone (Group 1) (MPa: 23.22 ± 5.24, p <0.05), with micro-cracks seen under SEM in Groups 3 and 4. Group 4 had the highest biocompatibility (p < 0.05) with osteoblasts as compared to Group 3 at all time points in vitro. Clinical handling tests indicated that Group 4 samples could better withstand drilling and screw placement but still demonstrated brittleness compared to Group 1. Hence, bovine bone blocks sintered at 1100 °C for 6 h resulted in highly pure bone with acceptable mechanical strength and clinical handling, suggesting it is a viable option as a block grafting material.
Collapse
Affiliation(s)
- Asrar Elahi
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, North Dunedin 9016, New Zealand
| | - Warwick Duncan
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, North Dunedin 9016, New Zealand
| | - Kai-Chun Li
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, North Dunedin 9016, New Zealand
| | - John Neil Waddell
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, North Dunedin 9016, New Zealand
| | - Dawn Coates
- Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, North Dunedin 9016, New Zealand
| |
Collapse
|
33
|
Berk T, Zderic I, Caspar J, Schwarzenberg P, Pastor T, Halvachizadeh S, Makelov B, Richards G, Pape HC, Gueorguiev B. A Novel Implant for Superior Pubic Ramus Fracture Fixation-Development and a Biomechanical Feasibility Study. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:medicina59040740. [PMID: 37109698 PMCID: PMC10142566 DOI: 10.3390/medicina59040740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/10/2023] [Accepted: 04/05/2023] [Indexed: 04/29/2023]
Abstract
Background and Objectives: Pubic ramus fractures are common in compound pelvic injuries known to have an increased rate of morbidity and mortality along with recurrent and chronic pain, impeding a patient's quality of life. The current standard treatment of these fractures is percutaneous screw fixation due to its reduced risk of blood loss and shorter surgery times. However, this is an intricate surgical technique associated with high failure rates of up to 15%, related to implant failure and loss of reduction. Therefore, the aim of this biomechanical feasibility study was to develop and test a novel intramedullary splinting implant for fixation of superior pubic ramus fractures (SPRF), and to evaluate its biomechanical viability in comparison with established fixation methods using conventional partially or fully threaded cannulated screws. Materials and Methods: A type II superior pubic ramus fracture according to the Nakatani classification was created in 18 composite hemi-pelvises via a vertical osteotomy with an additional osteotomy in the inferior pubic ramus to isolate the testing of three SPRF fixation techniques performed in 6 semi-pelvises each using either (1) a novel ramus intramedullary splint, (2) a partially threaded ramus screw, or (3) a fully threaded ramus screw. Results: No significant differences were detected among the fixation techniques in terms of initial construct stiffness and number of cycles to failure, p ≥ 0.213. Conclusion: The novel ramus intramedullary splint can be used as an alternative option for treatment of pubic ramus fractures and has the potential to decrease the rate of implant failures due to its minimally invasive implantation procedure.
Collapse
Affiliation(s)
- Till Berk
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
- Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
| | - Ivan Zderic
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | - Jan Caspar
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | | | - Torsten Pastor
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
- Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Lucerne, Switzerland
| | - Sascha Halvachizadeh
- Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
- Harald-Tscherne Laboratory for Orthopedic and Trauma Research, University of Zurich, Sternwartstrasse 14, 8091 Zurich, Switzerland
| | - Biser Makelov
- University Multiprofile Hospital for Active Treatment 'Prof. Stoyan Kirkovitch', Trakia University, 6003 Stara Zagora, Bulgaria
| | - Geoff Richards
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| | - Hans-Christoph Pape
- Department of Trauma, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland
- Department of Orthopaedic and Trauma Surgery, Cantonal Hospital Lucerne, 6000 Lucerne, Switzerland
| | - Boyko Gueorguiev
- AO Research Institute Davos, Clavadelerstrasse 8, 7270 Davos, Switzerland
| |
Collapse
|
34
|
Olasinde AA, Faola AA, Oluwadiya KS. Chronic posterior dislocation of the right hip treated with bipolar hemiarthroplasty in resource limited environment- a case report. Int J Surg Case Rep 2023; 105:108065. [PMID: 36996702 PMCID: PMC10074564 DOI: 10.1016/j.ijscr.2023.108065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/16/2023] [Accepted: 03/17/2023] [Indexed: 03/30/2023] Open
Abstract
INTRODUCTION AND IMPORTANCE Chronic traumatic posterior dislocation of the hip is one of the uncommon conditions that surgeons in developing countries have to treat due to continued unvetted patronage of traditional bone setters by patients. It usually treatment challenges due to limitation in option available because resource constraints. CASE PRESENTATION We present the case of 42-year-old male patient who presented to our hospital one and half years after sustaining road traffic accident. He had initial failed treatment with the traditional bone setters that left him with persistent right hip pain, limp, shortening and limitation of movement. He had initial heavy skeletal traction before an uneventful right bipolar hemiarthroplasty was done. His Harris hip score improved from 40.6 (preoperative) to 90.4 (postoperative). CLINICAL DISCUSSION Chronic posterior dislocation is a rarity in developed countries but is gradually becoming a common occurrence in developing countries. While total hip replacement is advocated in developed countries this may not be readily available due to financial constraints, poor access to the hospital, and fewer Orthopaedic surgeons to population ratios. This makes bipolar hemiarthroplasty used in this a readily available option that yielded a comparatively good outcome. CONCLUSION We propose that bipolar hemiarthroplasty is viable alternative to total Hip replacement in chronic posterior hip dislocation in resource limited environment where access to this procedure may not be easily available.
Collapse
Affiliation(s)
- Anthony Ayotunde Olasinde
- Department of Surgery, Faculty of Clinical Medicine and Dentistry, Kampala International University (Western campus), Ishaka-Bushenyi, Uganda.
| | | | | |
Collapse
|
35
|
Sigusch B, Kranz S, von Hohenberg AC, Wehle S, Guellmar A, Steen D, Berg A, Rabe U, Heyder M, Reise M. Histological and Histomorphometric Evaluation of Implanted Photodynamic Active Biomaterials for Periodontal Bone Regeneration in an Animal Study. Int J Mol Sci 2023; 24:ijms24076200. [PMID: 37047171 PMCID: PMC10094716 DOI: 10.3390/ijms24076200] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/17/2023] [Accepted: 03/22/2023] [Indexed: 03/29/2023] Open
Abstract
Recently, our group developed two different polymeric biomaterials with photodynamic antimicrobial surface activity for periodontal bone regeneration. The aim of the present study was to analyze the biocompatibility and osseointegration of these materials in vivo. Two biomaterials based on urethane dimethacrylate (BioM1) and tri-armed oligoester-urethane methacrylate (BioM2) that additionally contained ß-tricalcium phosphate and the photosensitizer mTHPC (meso-tetra(hydroxyphenyl)chlorin) were implanted in non-critical size bone defects in the femur (n = 16) and tibia (n = 8) of eight female domestic sheep. Bone specimens were harvested and histomorphometrically analyzed after 12 months. BioM1 degraded to a lower extent which resulted in a mean remnant square size of 17.4 mm², while 12.2 mm² was estimated for BioM2 (p = 0.007). For BioM1, a total percentage of new formed bone by 30.3% was found which was significant higher compared to BioM2 (8.4%, p < 0.001). Furthermore, BioM1 was afflicted by significant lower soft tissue formation (3.3%) as compared to BioM2 (29.5%). Additionally, a bone-to-biomaterial ratio of 81.9% was detected for BioM1, while 8.5% was recorded for BioM2. Implantation of BioM2 caused accumulation of inflammatory cells and led to fibrous encapsulation. BioM1 (photosensitizer-armed urethane dimethacrylate) showed favorable regenerative characteristics and can be recommended for further studies.
Collapse
Affiliation(s)
- Bernd Sigusch
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| | - Stefan Kranz
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
- Correspondence:
| | - Andreas Clemm von Hohenberg
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| | - Sabine Wehle
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| | - André Guellmar
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| | | | - Albrecht Berg
- Innovent Technologieentwicklung e.V., 07745 Jena, Germany
| | - Ute Rabe
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| | - Markus Heyder
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| | - Markus Reise
- Department of Conservative Dentistry and Periodontology, University Hospitals Jena, An der alten Post 4, 07743 Jena, Germany (A.C.v.H.)
| |
Collapse
|
36
|
Ammarullah MI, Hartono R, Supriyono T, Santoso G, Sugiharto S, Permana MS. Polycrystalline Diamond as a Potential Material for the Hard-on-Hard Bearing of Total Hip Prosthesis: Von Mises Stress Analysis. Biomedicines 2023; 11:951. [PMID: 36979930 PMCID: PMC10045939 DOI: 10.3390/biomedicines11030951] [Citation(s) in RCA: 61] [Impact Index Per Article: 30.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/14/2023] [Accepted: 03/14/2023] [Indexed: 03/30/2023] Open
Abstract
Due to polymeric wear debris causing osteolysis from polymer, metal ions causing metallosis from metal, and brittle characteristic causing fracture failure from ceramic in the application on bearing of total hip prosthesis requires the availability of new material options as a solution to these problems. Polycrystalline diamond (PCD) has the potential to become the selected material for hard-on-hard bearing in view of its advantages in terms of mechanical properties and biocompatibility. The present study contributes to confirming the potential of PCD to replace metals and ceramics for hard-on-hard bearing through von Mises stress investigations. A computational simulation using a 2D axisymmetric finite element model of hard-on-hard bearing under gait loading has been performed. The percentage of maximum von Mises stress to respective yield strength from PCD-on-PCD is the lowest at 2.47%, with CoCrMo (cobalt chromium molybdenum)-on-CoCrMo at 10.79%, and Al2O3 (aluminium oxide)-on-Al2O3 at 13.49%. This confirms that the use of PCD as a hard-on-hard bearing material is the safest option compared to the investigated metal and ceramic hard-on-hard bearings from the mechanical perspective.
Collapse
Affiliation(s)
- Muhammad Imam Ammarullah
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung 40153, West Java, Indonesia
| | - Rachmad Hartono
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
| | - Toto Supriyono
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung 40153, West Java, Indonesia
| | - Gatot Santoso
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung 40153, West Java, Indonesia
| | - S. Sugiharto
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung 40153, West Java, Indonesia
| | - Muki Satya Permana
- Department of Mechanical Engineering, Faculty of Engineering, Universitas Pasundan, Bandung 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Universitas Pasundan, Bandung 40153, West Java, Indonesia
| |
Collapse
|
37
|
Ferrini F, Paolone G, Di Domenico GL, Pagani N, Gherlone EF. SEM Evaluation of the Marginal Accuracy of Zirconia, Lithium Disilicate, and Composite Single Crowns Created by CAD/CAM Method: Comparative Analysis of Different Materials. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2413. [PMID: 36984293 PMCID: PMC10058296 DOI: 10.3390/ma16062413] [Citation(s) in RCA: 32] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/12/2023] [Accepted: 03/15/2023] [Indexed: 06/18/2023]
Abstract
(1) Background: The objective of this in vitro study is to evaluate the marginal accuracy of crowns created by CAD/CAM. (2) Methods: A customized chrome-cobalt (Cr-Co) implant abutment simulating a maxillary right first molar was fixed in a hemi-maxillary stone model and scanned. In total, 27 crowns were fabricated, including 9 lithium disilicate crowns, 9 composite crowns, and 9 zirconia crowns. The measurements were determined by scanning electron microscopy. Descriptive analysis was performed using the mean and standard deviation, while the Kruskal-Wallis test was performed to determine whether the marginal discrepancies were significantly different between each group (p < 0.05). (3) Results: The lowest marginal gap value was reported for zirconia (21.45 ± 12.58 µm), followed by composite (44.7 ± 24.96 µm) and lithium disilicate (62.28 ± 51.8 µm). The Kruskal-Wallis tests revealed a statistically significant difference (p-value < 0.05) in the mean marginal gaps between different materials. (4) Conclusions: The proposed digital workflow can be a viable alternative for fixed prosthetic rehabilitations. The best performance in terms of marginal gap was achieved by zirconia crowns, but all three materials demonstrate marginal closure below the clinically accepted threshold value (120 µm). Clinical significance: although significant differences were reported, the investigated CAD/CAM materials showed clinically acceptable marginal gaps.
Collapse
Affiliation(s)
- Francesco Ferrini
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | - Gaetano Paolone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | | | - Nicolò Pagani
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| | - Enrico Felice Gherlone
- Dental School, IRCCS San Raffaele Hospital, Vita-Salute San Raffaele University, 20132 Milan, Italy
| |
Collapse
|
38
|
Woo S, Lee Y, Sun D. A Pilot Experiment to Measure the Initial Mechanical Stability of the Femoral Head Implant in a Cadaveric Model of Osteonecrosis of Femoral Head Involving up to 50% of the Remaining Femoral Head. Medicina (B Aires) 2023; 59:medicina59030508. [PMID: 36984509 PMCID: PMC10051982 DOI: 10.3390/medicina59030508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 02/27/2023] [Accepted: 03/01/2023] [Indexed: 03/08/2023] Open
Abstract
Background and Objectives: Currently, only patients with osteonecrosis of the femoral head (ONFH), who had bone defects involving 30–33.3% of the remaining femoral head, are indicated in hip resurfacing arthroplasty (HRA). In an experimental cadaver model of ONFH involving up to 50% of the remaining femoral head, the initial stability of the femoral head implant (FHI) at the interface between the implant and the remaining femoral head was measured. Materials and Methods: The ten specimens and the remaining ten served as the experimental group and the control group, respectively. We examined the degree of the displacement of the FHI, the bonding strength between the FHI and the retained bone and that at the interface between the FHI and bone cement. Results: Changes in the degree of displacement at the final phase from the initial phase were calculated as 0.089 ± 0.036 mm in the experimental group and 0.083 ± 0.056 mm in the control group. However, this difference reached no statistical significance (p = 0.7789). Overall, there was an increase in the degree of displacement due to the loading stress, with increased loading cycles in both groups. In cycles of up to 6000 times, there was a steep increase. After cycles of 8000 times, however, there was a gradual increase. Moreover, in cycles of up to 8000 times, there was an increase in the difference in the degree of displacement due to the loading stress between the two groups. After cycles of 8000 times, however, such difference remained almost unchanged. Conclusions: In conclusion, orthopedic surgeons could consider performing the HRA in patients with ONFH where the bone defects involved up to 50% of the remaining femoral head, without involving the femoral head–neck junction in the anterior and superior area of the femoral head. However, more evidence-based studies are warranted to justify our results.
Collapse
Affiliation(s)
| | | | - Doohoon Sun
- Correspondence: ; Tel.: +82-422-208-460; Fax: +82-422-208-464
| |
Collapse
|
39
|
Tauviqirrahman M, Ammarullah MI, Jamari J, Saputra E, Winarni TI, Kurniawan FD, Shiddiq SA, van der Heide E. Analysis of contact pressure in a 3D model of dual-mobility hip joint prosthesis under a gait cycle. Sci Rep 2023; 13:3564. [PMID: 36864170 PMCID: PMC9981612 DOI: 10.1038/s41598-023-30725-6] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Accepted: 02/28/2023] [Indexed: 03/04/2023] Open
Abstract
Hip joint prostheses are used to replace hip joint function in the human body. The latest dual-mobility hip joint prosthesis has an additional component of an outer liner that acts as a cover for the liner component. Research on the contact pressure generated on the latest model of a dual-mobility hip joint prosthesis under a gait cycle has never been done before. The model is made of ultrahigh molecular weight polyethylene (UHMWPE) on the inner liner and 316L stainless steel (SS 316L) on the outer liner and acetabular cup. Simulation modeling using the finite element method is considered static loading with an implicit solver for studying the geometric parameter design of dual-mobility hip joint prostheses. In this study, simulation modeling was carried out by applying varying inclination angles of 30°, 40°, 45°, 50°, 60°, and 70° to the acetabular cup component. Three-dimensional loads were placed on femoral head reference points with variations of femoral head diameter used at 22 mm, 28 mm, and 32 mm. The results in the inner surface of the inner liner, the outer surface of the outer liner, and the inner surface of the acetabular cup showed that the variations in inclination angle do not have a major effect on the maximum contact pressure value on the liner component, where the acetabular cup with an inclination angle of 45° can reduce contact pressure more than the other studied inclination angle variations. In addition, it was found that the 22 mm diameter of the femoral head increases the contact pressure. The use of a larger diameter femoral head with an acetabular cup configuration at a 45° inclination can minimize the risk of implant failure due to wear.
Collapse
Affiliation(s)
- Mohammad Tauviqirrahman
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Central Java, Indonesia.
| | - Muhammad Imam Ammarullah
- Department of Mechanical Engineering, Faculty of Engineering, Pasundan University, Bandung, 40153, West Java, Indonesia
- Biomechanics and Biomedics Engineering Research Centre, Pasundan University, Bandung, 40153, West Java, Indonesia
- Undip Biomechanics Engineering and Research Centre (UBM-ERC), Diponegoro University, Semarang, 50275, Central Java, Indonesia
| | - J Jamari
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Central Java, Indonesia
- Undip Biomechanics Engineering and Research Centre (UBM-ERC), Diponegoro University, Semarang, 50275, Central Java, Indonesia
| | - Eko Saputra
- Department of Mechanical Engineering, Semarang State Polytechnic, Semarang, 50275, Central Java, Indonesia
| | - Tri Indah Winarni
- Undip Biomechanics Engineering and Research Centre (UBM-ERC), Diponegoro University, Semarang, 50275, Central Java, Indonesia
- Department of Anatomy, Faculty of Medicine, Diponegoro University, Semarang, 50275, Central Java, Indonesia
- Center for Biomedical Research (CEBIOR), Faculty of Medicine, Diponegoro University, Semarang, 50275, Central Java, Indonesia
| | - Febri Dwi Kurniawan
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Central Java, Indonesia
- Undip Biomechanics Engineering and Research Centre (UBM-ERC), Diponegoro University, Semarang, 50275, Central Java, Indonesia
| | - Shidnan Amir Shiddiq
- Department of Mechanical Engineering, Faculty of Engineering, Diponegoro University, Semarang, 50275, Central Java, Indonesia
- Undip Biomechanics Engineering and Research Centre (UBM-ERC), Diponegoro University, Semarang, 50275, Central Java, Indonesia
| | - Emile van der Heide
- Department of Mechanics of Solids, Surfaces and Systems (MS3), Faculty of Engineering Technology, University of Twente, Postbox 217, 7500 AE, Enschede, The Netherlands
- Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente, Postbox 217, 7500 AE, Enschede, The Netherlands
| |
Collapse
|
40
|
Modica F, Basile V, Surace R, Fassi I. Replication Study of Molded Micro-Textured Samples Made of Ultra-High Molecular Weight Polyethylene for Medical Applications. MICROMACHINES 2023; 14:523. [PMID: 36984930 PMCID: PMC10051488 DOI: 10.3390/mi14030523] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/22/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
In articular joint implants, polymeric inserts are usually exploited for on-contact sliding surfaces to guarantee low friction and wear, a high load-bearing capacity, impact strength and stiffness, and biocompatibility. Surface micro-structuring can drastically reduce friction and wear by promoting hydrostatic friction due to synovial fluid. Ultra-High Molecular Weight Polyethylene (UHMWPE) is a suitable material for these applications due to its strong chemical resistance, excellent resistance to stress, cracking, abrasion, and wear, and self-lubricating property. However, surface micro-texturing of UHMWPE is hardly achievable with the currently available processes. The present study investigates UHMWPE's micro-textured surface replication capability via injection molding, comparing the results with the more easily processable High-Density Polyethylene (HDPE). Four different micro-texture cavities were designed and fabricated on a steel mold by micro-EDM milling, and used for the experimental campaign. Complete samples were fabricated with both materials. Then, the mold and samples were geometrically characterized, considering the dimensions of the features and the texture layout. The replication analysis showed that HDPE samples present geometrical errors that span from 1% to 9% resulting in an average error of 4.3%. In comparison, the UHMWPE samples display a higher variability, although still acceptable, with percentage errors ranging from 2% to 31% and an average error of 11.4%.
Collapse
Affiliation(s)
- Francesco Modica
- CNR-STIIMA Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing, Via P. Lembo, 38F, 70124 Bari, Italy
| | - Vito Basile
- CNR-STIIMA Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing, Via P. Lembo, 38F, 70124 Bari, Italy
| | - Rossella Surace
- CNR-STIIMA Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing, Via P. Lembo, 38F, 70124 Bari, Italy
| | - Irene Fassi
- CNR-STIIMA Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing, Via A. Corti, 12, 20133 Milano, Italy
| |
Collapse
|
41
|
Morton’s Extension on Hallux Rigidus Pathology. PROSTHESIS 2023. [DOI: 10.3390/prosthesis5010019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
Study design, case-control study: Background, Morton’s extension (ME) is a kind of orthotic that has been used as a conservative treatment of painful hallux rigidus (HR) osteoarthritis, but only their effects on first metatarsophalangeal joint (MPJ) mobility and position in healthy subjects have been studied, but not on its applied pulled tension forces neither in subjects with HR. Objectives: This study sought to understand how ME’s orthotics with three different thicknesses could influence the kinematic first MPJ by measuring hallux dorsiflexion using Jack’s test and a digital algometer with a rigid strip anchored to the iron hook’s extremity and comparing subjects with healthy first MPJ mobility to those with HR. We aimed to clarify whether tension values were different between healthy and HR subjects. Methods: Fifty-eight subjects were selected, of whom thirty were included in the case group according to HR criteria and twenty-eight were included in the control group. A digital algometer (FPX®® 25, Wagner Instruments®®, Greenwich, CT, USA) was used to assess the pulled tension values (kgf) of the first MPJ during Jack’s test. Results: The pulled tension values were highly reliable (ICC > 0.963). There were no statistically significant differences between the pulled tension values for the different ME conditions in the case (p = 0.969) or control (p = 0.718) groups. However, as it’s expected, there were statistically significant differences comparing all pulled tension values between case and control group subjects (p < 0.001). Conclusions: Different ME’s thicknesses had no influence on the pulled effort applied during the dorsiflexion Jack’s test between the healthy and HR groups; therefore, it can be prescribed without joint-care danger. In addition, it is proven that there is greater resistance to performing Jack’s test in the HR group than in the healthy group, regardless of ME’s orthotics. Furthermore, it is shown that the digital algometer device is a valid tool to detect the first MPJ restriction and is more reliable than other tests.
Collapse
|
42
|
Advances in the Microbiological Diagnosis of Prosthetic Joint Infections. Diagnostics (Basel) 2023; 13:diagnostics13040809. [PMID: 36832297 PMCID: PMC9954824 DOI: 10.3390/diagnostics13040809] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2023] [Revised: 01/31/2023] [Accepted: 02/17/2023] [Indexed: 02/25/2023] Open
Abstract
A significant number of prosthetic joint infections (PJI) are culture-negative and/or misinterpreted as aseptic failures in spite of the correct implementation of diagnostic culture techniques, such as tissue sample processing in a bead mill, prolonged incubation time, or sonication of removed implants. Misinterpretation may lead to unnecessary surgery and needless antimicrobial treatment. The diagnostic value of non-culture techniques has been investigated in synovial fluid, periprosthetic tissues, and sonication fluid. Different feasible improvements, such as real-time technology, automated systems and commercial kits are now available to support microbiologists. In this review, we describe non-culture techniques based on nucleic acid amplification and sequencing methods. Polymerase chain reaction (PCR) is a frequently used technique in most microbiology laboratories which allows the detection of a nucleic acid fragment by sequence amplification. Different PCR types can be used to diagnose PJI, each one requiring the selection of appropriate primers. Henceforward, thanks to the reduced cost of sequencing and the availability of next-generation sequencing (NGS), it will be possible to identify the whole pathogen genome sequence and, additionally, to detect all the pathogen sequences present in the joint. Although these new techniques have proved helpful, strict conditions need to be observed in order to detect fastidious microorganisms and rule out contaminants. Specialized microbiologists should assist clinicians in interpreting the result of the analyses at interdisciplinary meetings. New technologies will gradually be made available to improve the etiologic diagnoses of PJI, which will remain an important cornerstone of treatment. Strong collaboration among all specialists involved is essential for the correct diagnosis of PJI.
Collapse
|
43
|
Zhao H, Cao J, Liao WH. Simultaneous Estimation of the Vertical Stiffness in the Knee and Hip for Healthy Human Subjects during Walking. Bioengineering (Basel) 2023; 10:187. [PMID: 36829680 PMCID: PMC9952526 DOI: 10.3390/bioengineering10020187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 01/25/2023] [Accepted: 01/28/2023] [Indexed: 02/04/2023] Open
Abstract
The stiffness of lower limb joints is a critical characteristic of walking. To investigate the potential of establishing a simple and universal model to describe the characteristics related to vertical vibration during human walking, vertical stiffness is introduced at the knee and hip. A multi-mass-spring model of the human body is established in the vertical direction. In the Fourier form, results of experiments on 14 healthy adults show that the vertical displacements of joints are a function of the leg length and walking cadence, while the ground reaction force is a function of the body weight and walking cadence. The obtained universal equations of vertical displacement and ground reaction force are employed as the input parameters to the proposed multi-mass-spring model. Thus, the vertical stiffness in the knee and hip can then be estimated simultaneously by the subject's weight, leg length, and walking cadence. The variation of vertical stiffness shows different time-varying trends in different gait phases across the entire gait cycle. Finally, the proposed model for vertical stiffness estimation is validated by the vertical oscillation of the pelvis. The average error across three gait cycles for all subjects is 20.48%, with a standard deviation of 5.44%. These results display that the vertical stiffness of knee and hip across the entire gait cycle can be directly estimated by individual parameters that are easy to measure. It provides a different view of human walking analysis and may be applied in future pathological gait recognition, bipedal robots, and lower limb exoskeletons.
Collapse
Affiliation(s)
- Huan Zhao
- Key Laboratory of Education Ministry for Modern Design and Rotor Bearing System, Xi’an Jiaotong University, 28 Xianning West Road, Xi’an 710049, China
| | - Junyi Cao
- Key Laboratory of Education Ministry for Modern Design and Rotor Bearing System, Xi’an Jiaotong University, 28 Xianning West Road, Xi’an 710049, China
| | - Wei-Hsin Liao
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, N.T., Hong Kong 999077, China
| |
Collapse
|
44
|
Developing Patient-Specific Statistical Reconstructions of Healthy Anatomical Structures to Improve Patient Outcomes. Bioengineering (Basel) 2023; 10:bioengineering10020123. [PMID: 36829617 PMCID: PMC9952233 DOI: 10.3390/bioengineering10020123] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 01/12/2023] [Accepted: 01/13/2023] [Indexed: 01/19/2023] Open
Abstract
There are still numerous problems with modern joint replacement prostheses, which negatively influence patient health and recovery. For example, it is especially important to avoid failures and complications following hip arthroplasty because the loss of hip joint function is commonly associated with increased demand on the healthcare system, reoperation, loss of independence, physical disability, and death. The current study uses hip arthroplasty as a model system to present a new strategy of computationally generating patient-specific statistical reconstructions of complete healthy anatomical structures from computed tomography (CT) scans of damaged anatomical structures. The 3D model morphological data were evaluated from damaged femurs repaired with prosthetic devices and the respective damaged femurs that had been restored using statistical reconstruction. The results from all morphological measurements (i.e., maximum femoral length, Hausdorff distance, femoral neck anteversion, length of rotational center divergence, and angle of inclination) indicated that the values of femurs repaired with traditional prostheses did not fall within the +/-3 standard deviations of the respective patient-specific healthy anatomical structures. These results demonstrate that there are quantitative differences in the morphology of femurs repaired with traditional prostheses and the morphology of patient-specific statistical reconstructions. This approach of generating patient-specific statistical reconstructions of healthy anatomical structures might help to inform prosthetic designs so that new prostheses more closely resemble natural healthy morphology and preserve biomechanical function. Additionally, the patient-specific statistical reconstructions of healthy anatomical structures might be valuable for surgeons in that prosthetic devices could be selected and positioned to more accurately restore natural biomechanical function. All in all, this contribution establishes the novel approach of generating patient-specific statistical reconstructions of healthy anatomical structures from the CT scans of individuals' damaged anatomical structures to improve treatments and patient outcomes.
Collapse
|