1
|
Zhang A, Haimowitz BJ, Tharwani K, Rojas-Peña A, Bartlett RH, Potkay JA. A Wearable Extracorporeal CO 2 Removal System with a Closed-Loop Feedback. Bioengineering (Basel) 2024; 11:969. [PMID: 39451346 PMCID: PMC11505386 DOI: 10.3390/bioengineering11100969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/19/2024] [Accepted: 09/21/2024] [Indexed: 10/26/2024] Open
Abstract
Extracorporeal Carbon Dioxide Removal (ECCO2R) systems support patients with severe respiratory failure. Concurrent ambulation and physical therapy improve patient outcomes, but these procedures are limited by the complexity and size of the extracorporeal systems and rapid changes in patient metabolism and the acid-base balance. Here, we present the first prototype of a wearable ECCO2R system capable of adjusting to a patient's changing metabolic needs. Exhaust gas CO2 (EGCO2) partial pressure is used as an analog for blood CO2 partial pressure (pCO2). Twin blowers modulate sweep gas through the AL to achieve a desired target EGCO2. The integrated system was tested in vitro for 24 h with water, under varying simulated metabolic conditions and target EGCO2 values, and in a single test with whole blood. When challenged with changing inlet water pCO2 levels in in vitro tests, the system adjusted the sweep gas to achieve target EGCO2 within 1 min. Control runs with a fixed sweep gas (without negative feedback) demonstrated higher EGCO2 levels when challenged with higher water flow rates. A single in vitro test with whole ovine blood confirmed functionality in blood. This is the first step toward wearable ECCO2R systems that automatically respond to changing metabolism. Such devices would facilitate physical therapy and grant greater autonomy to patients.
Collapse
Affiliation(s)
- Andrew Zhang
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (A.Z.); (A.R.-P.); (R.H.B.)
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| | - Brian J. Haimowitz
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (A.Z.); (A.R.-P.); (R.H.B.)
| | - Kartik Tharwani
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (A.Z.); (A.R.-P.); (R.H.B.)
| | - Alvaro Rojas-Peña
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (A.Z.); (A.R.-P.); (R.H.B.)
| | - Robert H. Bartlett
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (A.Z.); (A.R.-P.); (R.H.B.)
| | - Joseph A. Potkay
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (A.Z.); (A.R.-P.); (R.H.B.)
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| |
Collapse
|
2
|
Zhang A, Tharwani K, Wang J, Seilo GK, Atie MA, Potkay JA. Roll-to-roll manufacturing of large surface area PDMS devices, and application to a microfluidic artificial lung. LAB ON A CHIP 2024; 24:4357-4370. [PMID: 39148312 PMCID: PMC11327552 DOI: 10.1039/d4lc00339j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2024] [Accepted: 07/16/2024] [Indexed: 08/17/2024]
Abstract
The ability to cost-effectively produce large surface area microfluidic devices would bring many small-scale technologies such as microfluidic artificial lungs (μALs) from the realm of research to clinical and commercial applications. However, efforts to scale up these devices, such as by stacking multiple flat μALs have been labor intensive and resulted in bulky devices. Here, we report an automated manufacturing system, and a series of cylindrical multi-layer lungs manufactured with the system and tested for fluidic fidelity and function. A roll-to-roll (R2R) system to engrave multiple-layer devices was assembled. Unlike typical applications of R2R, the rolling process is synchronized to achieve consistent radial positioning. This allows the fluidics in the final device to be accessed without being unwrapped. To demonstrate the capabilities of the R2R manufacturing system, this method was used to manufacture multi-layer μALs. Gas and blood are engraved in alternating layers and routed orthogonally to each other. The proximity of gas and blood separated by gas permeable PDMS permits CO2 and O2 exchange via diffusion. After manufacturing, they were evaluated using water for pressure drop and CO2 gas exchange. The best performing device was tested with fresh whole bovine blood for O2 exchange. Three μALs were successfully manufactured and passed leak testing. The top performing device had 15 alternating blood and gas layers. It oxygenated blood from 70% saturation to 95% saturation at a blood flow of 3 mL min-1 and blood side pressure drop of 234 mmHg. This new roll-to-roll manufacturing system is suitable for the automated construction of multi-layer microfluidic devices that are difficult to manufacture by conventional means. With some upgrades and improvements, this technology should allow for the automatic creation of large surface area microfluidic devices that can be employed for various applications including large-scale membrane gas exchange such as clinical-scale microfluidic artificial lungs.
Collapse
Affiliation(s)
- Andrew Zhang
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
- Ann Arbor Veteran Affairs Healthcare System, Ann Arbor, MI 48105, USA
| | - Kartik Tharwani
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| | - Jennifer Wang
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| | - Gabriele K Seilo
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| | - Michael A Atie
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
- Ann Arbor Veteran Affairs Healthcare System, Ann Arbor, MI 48105, USA
| | - Joseph A Potkay
- ECLS Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
- Ann Arbor Veteran Affairs Healthcare System, Ann Arbor, MI 48105, USA
| |
Collapse
|
3
|
Calzuola ST, Newman G, Feaugas T, Perrault CM, Blondé JB, Roy E, Porrini C, Stojanovic GM, Vidic J. Membrane-based microfluidic systems for medical and biological applications. LAB ON A CHIP 2024; 24:3579-3603. [PMID: 38954466 DOI: 10.1039/d4lc00251b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
Microfluidic devices with integrated membranes that enable control of mass transport in constrained environments have shown considerable growth over the last decade. Membranes are a key component in several industrial processes such as chemical, pharmaceutical, biotechnological, food, and metallurgy separation processes as well as waste management applications, allowing for modular and compact systems. Moreover, the miniaturization of a process through microfluidic devices leads to process intensification together with reagents, waste and cost reduction, and energy and space savings. The combination of membrane technology and microfluidic devices allows therefore magnification of their respective advantages, providing more valuable solutions not only for industrial processes but also for reproducing biological processes. This review focuses on membrane-based microfluidic devices for biomedical science with an emphasis on microfluidic artificial organs and organs-on-chip. We provide the basic concepts of membrane technology and the laws governing mass transport. The role of the membrane in biomedical microfluidic devices, along with the required properties, available materials, and current challenges are summarized. We believe that the present review may be a starting point and a resource for researchers who aim to replicate a biological phenomenon on-chip by applying membrane technology, for moving forward the biomedical applications.
Collapse
Affiliation(s)
- Silvia Tea Calzuola
- UMR7646 Laboratoire d'hydrodynamique (LadHyX), Ecole Polytechnique, Palaiseau, France.
- Eden Tech, Paris, France
| | - Gwenyth Newman
- Eden Tech, Paris, France
- Department of Medicine and Surgery, Università degli Studi di Milano-Bicocca, Milan, Italy
| | - Thomas Feaugas
- Eden Tech, Paris, France
- Department of Medicine and Surgery, Università degli Studi di Milano-Bicocca, Milan, Italy
| | | | | | | | | | - Goran M Stojanovic
- Faculty of Technical Sciences, University of Novi Sad, T. D. Obradovića 6, 21000 Novi Sad, Serbia
| | - Jasmina Vidic
- Micalis Institute, INRAE, AgroParisTech, Université Paris-Saclay, Jouy-en-Josas, France
| |
Collapse
|
4
|
Roberts TR, Persello A, Harea GT, Vedula EM, Isenberg BC, Zang Y, Santos J, Borenstein JT, Batchinsky AI. First 24-Hour-Long Intensive Care Unit Testing of a Clinical-Scale Microfluidic Oxygenator in Swine: A Safety and Feasibility Study. ASAIO J 2024; 70:535-544. [PMID: 38165978 DOI: 10.1097/mat.0000000000002127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2024] Open
Abstract
Microfluidic membrane oxygenators are designed to mimic branching vasculature of the native lung during extracorporeal lung support. To date, scaling of such devices to achieve clinically relevant blood flow and lung support has been a limitation. We evaluated a novel multilayer microfluidic blood oxygenator (BLOx) capable of supporting 750-800 ml/min blood flow versus a standard hollow fiber membrane oxygenator (HFMO) in vivo during veno-venous extracorporeal life support for 24 hours in anesthetized, mechanically ventilated uninjured swine (n = 3/group). The objective was to assess feasibility, safety, and biocompatibility. Circuits remained patent and operated with stable pressures throughout 24 hours. No group differences in vital signs or evidence of end-organ damage occurred. No change in plasma free hemoglobin and von Willebrand factor multimer size distribution were observed. Platelet count decreased in BLOx at 6 hours (37% dec, P = 0.03), but not in HFMO; however, thrombin generation potential was elevated in HFMO (596 ± 81 nM·min) versus BLOx (323 ± 39 nM·min) at 24 hours ( P = 0.04). Other coagulation and inflammatory mediator results were unremarkable. BLOx required higher mechanical ventilator settings and showed lower gas transfer efficiency versus HFMO, but the stable device performance indicates that this technology is ready for further performance scaling and testing in lung injury models and during longer use conditions.
Collapse
Affiliation(s)
- Teryn R Roberts
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - Antoine Persello
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - George T Harea
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - Else M Vedula
- Bioengineering Division, Draper, Cambridge, Massachusetts
| | | | - Yanyi Zang
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| | - Jose Santos
- Bioengineering Division, Draper, Cambridge, Massachusetts
| | | | - Andriy I Batchinsky
- From the Autonomous Reanimation and Evacuation Research Program, The Geneva Foundation, San Antonio, Texas
| |
Collapse
|
5
|
Tonetti T, Zanella A, Pérez-Torres D, Grasselli G, Ranieri VM. Current knowledge gaps in extracorporeal respiratory support. Intensive Care Med Exp 2023; 11:77. [PMID: 37962702 PMCID: PMC10645840 DOI: 10.1186/s40635-023-00563-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Accepted: 11/08/2023] [Indexed: 11/15/2023] Open
Abstract
Extracorporeal life support (ECLS) for acute respiratory failure encompasses veno-venous extracorporeal membrane oxygenation (V-V ECMO) and extracorporeal carbon dioxide removal (ECCO2R). V-V ECMO is primarily used to treat severe acute respiratory distress syndrome (ARDS), characterized by life-threatening hypoxemia or ventilatory insufficiency with conventional protective settings. It employs an artificial lung with high blood flows, and allows improvement in gas exchange, correction of hypoxemia, and reduction of the workload on the native lung. On the other hand, ECCO2R focuses on carbon dioxide removal and ventilatory load reduction ("ultra-protective ventilation") in moderate ARDS, or in avoiding pump failure in acute exacerbated chronic obstructive pulmonary disease. Clinical indications for V-V ECLS are tailored to individual patients, as there are no absolute contraindications. However, determining the ideal timing for initiating extracorporeal respiratory support remains uncertain. Current ECLS equipment faces issues like size and durability. Innovations include intravascular lung assist devices (ILADs) and pumpless devices, though they come with their own challenges. Efficient gas exchange relies on modern oxygenators using hollow fiber designs, but research is exploring microfluidic technology to improve oxygenator size, thrombogenicity, and blood flow capacity. Coagulation management during V-V ECLS is crucial due to common bleeding and thrombosis complications; indeed, anticoagulation strategies and monitoring systems require improvement, while surface coatings and new materials show promise. Moreover, pharmacokinetics during ECLS significantly impact antibiotic therapy, necessitating therapeutic drug monitoring for precise dosing. Managing native lung ventilation during V-V ECMO remains complex, requiring a careful balance between benefits and potential risks for spontaneously breathing patients. Moreover, weaning from V-V ECMO is recognized as an area of relevant uncertainty, requiring further research. In the last decade, the concept of Extracorporeal Organ Support (ECOS) for patients with multiple organ dysfunction has emerged, combining ECLS with other organ support therapies to provide a more holistic approach for critically ill patients. In this review, we aim at providing an in-depth overview of V-V ECMO and ECCO2R, addressing various aspects of their use, challenges, and potential future directions in research and development.
Collapse
Affiliation(s)
- Tommaso Tonetti
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum-University of Bologna, Bologna, Italy
- Anesthesiology and General Intensive Care Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico di S.Orsola, Bologna, Italy
| | - Alberto Zanella
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - David Pérez-Torres
- Servicio de Medicina Intensiva, Hospital Universitario Río Hortega, Gerencia Regional de Salud de Castilla y León (SACYL), Calle Dulzaina, 2, 47012, Valladolid, Spain
| | - Giacomo Grasselli
- Department of Anesthesia, Critical Care and Emergency, Fondazione Istituto di Ricovero e Cura a Carattere Scientifico Ca' Granda Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
| | - V Marco Ranieri
- Department of Medical and Surgical Sciences (DIMEC), Alma Mater Studiorum-University of Bologna, Bologna, Italy
- Anesthesiology and General Intensive Care Unit, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Policlinico di S.Orsola, Bologna, Italy
| |
Collapse
|
6
|
Isenberg BC, Vedula EM, Santos J, Lewis DJ, Roberts TR, Harea G, Sutherland D, Landis B, Blumenstiel S, Urban J, Lang D, Teece B, Lai W, Keating R, Chiang D, Batchinsky AI, Borenstein JT. A Clinical-Scale Microfluidic Respiratory Assist Device with 3D Branching Vascular Networks. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2207455. [PMID: 37092588 PMCID: PMC10288269 DOI: 10.1002/advs.202207455] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/10/2023] [Indexed: 05/03/2023]
Abstract
Recent global events such as COVID-19 pandemic amid rising rates of chronic lung diseases highlight the need for safer, simpler, and more available treatments for respiratory failure, with increasing interest in extracorporeal membrane oxygenation (ECMO). A key factor limiting use of this technology is the complexity of the blood circuit, resulting in clotting and bleeding and necessitating treatment in specialized care centers. Microfluidic oxygenators represent a promising potential solution, but have not reached the scale or performance required for comparison with conventional hollow fiber membrane oxygenators (HFMOs). Here the development and demonstration of the first microfluidic respiratory assist device at a clinical scale is reported, demonstrating efficient oxygen transfer at blood flow rates of 750 mL min⁻1 , the highest ever reported for a microfluidic device. The central innovation of this technology is a fully 3D branching network of blood channels mimicking key features of the physiological microcirculation by avoiding anomalous blood flows that lead to thrombus formation and blood damage in conventional oxygenators. Low, stable blood pressure drop, low hemolysis, and consistent oxygen transfer, in 24-hour pilot large animal experiments are demonstrated - a key step toward translation of this technology to the clinic for treatment of a range of lung diseases.
Collapse
Affiliation(s)
| | | | - Jose Santos
- Bioengineering DivisionDraperCambridgeMA02139USA
| | | | - Teryn R. Roberts
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | - George Harea
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | | | - Beau Landis
- Bioengineering DivisionDraperCambridgeMA02139USA
| | | | - Joseph Urban
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Daniel Lang
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Bryan Teece
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - WeiXuan Lai
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Rose Keating
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Diana Chiang
- Bioengineering DivisionDraperCambridgeMA02139USA
| | - Andriy I. Batchinsky
- Autonomous Reanimation and Evacuation (AREVA) Research ProgramThe Geneva FoundationSan AntonioTX78234USA
| | | |
Collapse
|
7
|
Abstract
Extracorporeal membrane oxygenation (ECMO) has been advancing rapidly due to a combination of rising rates of acute and chronic lung diseases as well as significant improvements in the safety and efficacy of this therapeutic modality. However, the complexity of the ECMO blood circuit, and challenges with regard to clotting and bleeding, remain as barriers to further expansion of the technology. Recent advances in microfluidic fabrication techniques, devices, and systems present an opportunity to develop new solutions stemming from the ability to precisely maintain critical dimensions such as gas transfer membrane thickness and blood channel geometries, and to control levels of fluid shear within narrow ranges throughout the cartridge. Here, we present a physiologically inspired multilayer microfluidic oxygenator device that mimics physiologic blood flow patterns not only within individual layers but throughout a stacked device. Multiple layers of this microchannel device are integrated with a three-dimensional physiologically inspired distribution manifold that ensures smooth flow throughout the entire stacked device, including the critical entry and exit regions. We then demonstrate blood flows up to 200 ml/min in a multilayer device, with oxygen transfer rates capable of saturating venous blood, the highest of any microfluidic oxygenator, and a maximum blood flow rate of 480 ml/min in an eight-layer device, higher than any yet reported in a microfluidic device. Hemocompatibility and large animal studies utilizing these prototype devices are planned. Supplemental Visual Abstract, http://links.lww.com/ASAIO/A769.
Collapse
|
8
|
Ma LJ, Akor EA, Thompson AJ, Potkay JA. A Parametric Analysis of Capillary Height in Single-Layer, Small-Scale Microfluidic Artificial Lungs. MICROMACHINES 2022; 13:822. [PMID: 35744436 PMCID: PMC9229210 DOI: 10.3390/mi13060822] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 05/23/2022] [Accepted: 05/23/2022] [Indexed: 02/04/2023]
Abstract
Microfluidic artificial lungs (μALs) are being investigated for their ability to closely mimic the size scale and cellular environment of natural lungs. Researchers have developed μALs with small artificial capillary diameters (10-50 µm; to increase gas exchange efficiency) and with large capillary diameters (~100 µm; to simplify design and construction). However, no study has directly investigated the impact of capillary height on μAL properties. Here, we use Murray's law and the Hagen-Poiseuille equation to design single-layer, small-scale μALs with capillary heights between 10 and 100 µm. Each µAL contained two blood channel types: capillaries for gas exchange; and distribution channels for delivering blood to/from capillaries. Three designs with capillary heights of 30, 60, and 100 µm were chosen for further modeling, implementation and testing with blood. Flow simulations were used to validate and ensure equal pressures. Designs were fabricated using soft lithography. Gas exchange and pressure drop were tested using whole bovine blood. All three designs exhibited similar pressure drops and gas exchange; however, the μAL with 60 µm tall capillaries had a significantly higher wall shear rate (although physiologic), smaller priming volume and smaller total blood contacting surface area than the 30 and 100 µm designs. Future μAL designs may need to consider the impact of capillary height when optimizing performance.
Collapse
Affiliation(s)
- Lindsay J. Ma
- Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (L.J.M.); (E.A.A.); (A.J.T.)
- Veterans Affairs Ann Arbor Healthcare System, Ann Arbor, MI 48109, USA
| | - Emmanuel A. Akor
- Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (L.J.M.); (E.A.A.); (A.J.T.)
- Veterans Affairs Ann Arbor Healthcare System, Ann Arbor, MI 48109, USA
| | - Alex J. Thompson
- Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (L.J.M.); (E.A.A.); (A.J.T.)
- Veterans Affairs Ann Arbor Healthcare System, Ann Arbor, MI 48109, USA
| | - Joseph A. Potkay
- Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA; (L.J.M.); (E.A.A.); (A.J.T.)
- Veterans Affairs Ann Arbor Healthcare System, Ann Arbor, MI 48109, USA
| |
Collapse
|
9
|
Astor TL, Borenstein JT. The microfluidic artificial lung: Mimicking nature's blood path design to solve the biocompatibility paradox. Artif Organs 2022; 46:1227-1239. [PMID: 35514275 DOI: 10.1111/aor.14266] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 04/03/2022] [Accepted: 04/04/2022] [Indexed: 11/28/2022]
Abstract
The increasing prevalence of chronic lung disease worldwide, combined with the emergence of multiple pandemics arising from respiratory viruses over the past century, highlights the need for safer and efficacious means for providing artificial lung support. Mechanical ventilation is currently used for the vast majority of patients suffering from acute and chronic lung failure, but risks further injury or infection to the patient's already compromised lung function. Extracorporeal membrane oxygenation (ECMO) has emerged as a means of providing direct gas exchange with the blood, but limited access to the technology and the complexity of the blood circuit have prevented the broader expansion of its use. A promising avenue toward simplifying and minimizing complications arising from the blood circuit, microfluidics-based artificial organ support, has emerged over the past decade as an opportunity to overcome many of the fundamental limitations of the current standard for ECMO cartridges, hollow fiber membrane oxygenators. The power of microfluidics technology for this application stems from its ability to recapitulate key aspects of physiological microcirculation, including the small dimensions of blood vessel structures and gas transfer membranes. An even greater advantage of microfluidics, the ability to configure blood flow patterns that mimic the smooth, branching nature of vascular networks, holds the potential to reduce the incidence of clotting and bleeding and to minimize reliance on anticoagulants. Here, we summarize recent progress and address future directions and goals for this potentially transformative approach to artificial lung support.
Collapse
Affiliation(s)
- Todd L Astor
- Biomembretics, Inc., Boston, Massachusetts, USA.,Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | |
Collapse
|
10
|
Lachaux J, Hwang G, Arouche N, Naserian S, Harouri A, Lotito V, Casari C, Lok T, Menager JB, Issard J, Guihaire J, Denis CV, Lenting PJ, Barakat AI, Uzan G, Mercier O, Haghiri-Gosnet AM. A compact integrated microfluidic oxygenator with high gas exchange efficiency and compatibility for long-lasting endothelialization. LAB ON A CHIP 2021; 21:4791-4804. [PMID: 34309615 DOI: 10.1039/d1lc00356a] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We have developed and tested a novel microfluidic device for blood oxygenation, which exhibits a large surface area of gas exchange and can support long-term sustainable endothelialization of blood microcapillaries, enhancing its hemocompatibility for clinical applications. The architecture of the parallel stacking of the trilayers is based on a central injection for blood and a lateral injection/output for gas which allows significant reduction in shear stress, promoting sustainable endothelialization since cells can be maintained viable for up to 2 weeks after initial seeding in the blood microchannel network. The circular design of curved blood capillaries allows covering a maximal surface area at 4 inch wafer scale, producing high oxygen uptake and carbon dioxide release in each single unit. Since the conventional bonding process based on oxygen plasma cannot be used for surface areas larger than several cm2, a new "wet bonding" process based on soft microprinting has been developed and patented. Using this new protocol, each 4 inch trilayer unit can be sealed without a collapsed membrane even at reduced 15 μm thickness and can support a high blood flow rate. The height of the blood channels has been optimized to reduce pressure drop and enhance gas exchange at a high volumetric blood flow rate up to 15 ml min-1. The simplicity of connecting different units in the stacked architecture is demonstrated for 3- or 5-unit stacked devices that exhibit remarkable performance with low primary volume, high oxygen uptake and carbon dioxide release and high flow rate of up to 80 ml min-1.
Collapse
Affiliation(s)
- Julie Lachaux
- Université Paris-Saclay, CNRS, Centre de Nanosciences et Nanotechnologies C2N, UMR9001, Palaiseau 91120, France.
| | - Gilgueng Hwang
- Université Paris-Saclay, CNRS, Centre de Nanosciences et Nanotechnologies C2N, UMR9001, Palaiseau 91120, France.
| | - Nassim Arouche
- Université Paris-Saclay, INSERM, UMR-S-MD 1197, Hôpital Paul Brousse, Villejuif, France
| | - Sina Naserian
- Université Paris-Saclay, INSERM, UMR-S-MD 1197, Hôpital Paul Brousse, Villejuif, France
| | - Abdelmounaim Harouri
- Université Paris-Saclay, CNRS, Centre de Nanosciences et Nanotechnologies C2N, UMR9001, Palaiseau 91120, France.
| | - Valeria Lotito
- Université Paris-Saclay, CNRS, Centre de Nanosciences et Nanotechnologies C2N, UMR9001, Palaiseau 91120, France.
| | - Caterina Casari
- Université Paris-Saclay, INSERM, UMR S1176, Le Kremin-Bicêtre, France
| | - Thevy Lok
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau 91120, France
| | - Jean Baptiste Menager
- Université Paris-Saclay, INSERM UMR_S 999 "Pulmonary Hypertension: Pathophysiology and Novel Therapies", Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Justin Issard
- Université Paris-Saclay, INSERM UMR_S 999 "Pulmonary Hypertension: Pathophysiology and Novel Therapies", Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Julien Guihaire
- Université Paris-Saclay, INSERM UMR_S 999 "Pulmonary Hypertension: Pathophysiology and Novel Therapies", Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Cécile V Denis
- Université Paris-Saclay, INSERM, UMR S1176, Le Kremin-Bicêtre, France
| | - Peter J Lenting
- Université Paris-Saclay, INSERM, UMR S1176, Le Kremin-Bicêtre, France
| | - Abdul I Barakat
- LadHyX, CNRS, Ecole polytechnique, Institut polytechnique de Paris, Palaiseau 91120, France
| | - Georges Uzan
- Université Paris-Saclay, INSERM, UMR-S-MD 1197, Hôpital Paul Brousse, Villejuif, France
| | - Olaf Mercier
- Université Paris-Saclay, INSERM UMR_S 999 "Pulmonary Hypertension: Pathophysiology and Novel Therapies", Hôpital Marie Lannelongue, Le Plessis-Robinson, France
| | - Anne-Marie Haghiri-Gosnet
- Université Paris-Saclay, CNRS, Centre de Nanosciences et Nanotechnologies C2N, UMR9001, Palaiseau 91120, France.
| |
Collapse
|
11
|
Santos JA, Gimbel AA, Peppas A, Truslow JG, Lang DA, Sukavaneshvar S, Solt D, Mulhern TJ, Markoski A, Kim ES, Hsiao JCM, Lewis DJ, Harjes DI, DiBiasio C, Charest JL, Borenstein JT. Design and construction of three-dimensional physiologically-based vascular branching networks for respiratory assist devices. LAB ON A CHIP 2021; 21:4637-4651. [PMID: 34730597 DOI: 10.1039/d1lc00287b] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Microfluidic lab-on-a-chip devices are changing the way that in vitro diagnostics and drug development are conducted, based on the increased precision, miniaturization and efficiency of these systems relative to prior methods. However, the full potential of microfluidics as a platform for therapeutic medical devices such as extracorporeal organ support has not been realized, in part due to limitations in the ability to scale current designs and fabrication techniques toward clinically relevant rates of blood flow. Here we report on a method for designing and fabricating microfluidic devices supporting blood flow rates per layer greater than 10 mL min-1 for respiratory support applications, leveraging advances in precision machining to generate fully three-dimensional physiologically-based branching microchannel networks. The ability of precision machining to create molds with rounded features and smoothly varying channel widths and depths distinguishes the geometry of the microchannel networks described here from all previous reports of microfluidic respiratory assist devices, regarding the ability to mimic vascular blood flow patterns. These devices have been assembled and tested in the laboratory using whole bovine or porcine blood, and in a porcine model to demonstrate efficient gas transfer, blood flow and pressure stability over periods of several hours. This new approach to fabricating and scaling microfluidic devices has the potential to address wide applications in critical care for end-stage organ failure and acute illnesses stemming from respiratory viral infections, traumatic injuries and sepsis.
Collapse
Affiliation(s)
- Jose A Santos
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | - Alla A Gimbel
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | | | - Daniel A Lang
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | | | | | - Alex Markoski
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | - Ernest S Kim
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | - Diana J Lewis
- Bioengineering Division, Draper, Cambridge, MA, USA.
| | | | | | | | | |
Collapse
|
12
|
Santos J, Vedula EM, Lai W, Isenberg BC, Lewis DJ, Lang D, Sutherland D, Roberts TR, Harea GT, Wells C, Teece B, Karandikar P, Urban J, Risoleo T, Gimbel A, Solt D, Leazer S, Chung KK, Sukavaneshvar S, Batchinsky AI, Borenstein JT. Toward Development of a Higher Flow Rate Hemocompatible Biomimetic Microfluidic Blood Oxygenator. MICROMACHINES 2021; 12:888. [PMID: 34442512 PMCID: PMC8398684 DOI: 10.3390/mi12080888] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 07/18/2021] [Accepted: 07/24/2021] [Indexed: 01/05/2023]
Abstract
The recent emergence of microfluidic extracorporeal lung support technologies presents an opportunity to achieve high gas transfer efficiency and improved hemocompatibility relative to the current standard of care in extracorporeal membrane oxygenation (ECMO). However, a critical challenge in the field is the ability to scale these devices to clinically relevant blood flow rates, in part because the typically very low blood flow in a single layer of a microfluidic oxygenator device requires stacking of a logistically challenging number of layers. We have developed biomimetic microfluidic oxygenators for the past decade and report here on the development of a high-flow (30 mL/min) single-layer prototype, scalable to larger structures via stacking and assembly with blood distribution manifolds. Microfluidic oxygenators were designed with biomimetic in-layer blood distribution manifolds and arrays of parallel transfer channels, and were fabricated using high precision machined durable metal master molds and microreplication with silicone films, resulting in large area gas transfer devices. Oxygen transfer was evaluated by flowing 100% O2 at 100 mL/min and blood at 0-30 mL/min while monitoring increases in O2 partial pressures in the blood. This design resulted in an oxygen saturation increase from 65% to 95% at 20 mL/min and operation up to 30 mL/min in multiple devices, the highest value yet recorded in a single layer microfluidic device. In addition to evaluation of the device for blood oxygenation, a 6-h in vitro hemocompatibility test was conducted on devices (n = 5) at a 25 mL/min blood flow rate with heparinized swine donor blood against control circuits (n = 3). Initial hemocompatibility results indicate that this technology has the potential to benefit future applications in extracorporeal lung support technologies for acute lung injury.
Collapse
Affiliation(s)
- Jose Santos
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Else M. Vedula
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Weixuan Lai
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Brett C. Isenberg
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Diana J. Lewis
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Dan Lang
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - David Sutherland
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Teryn R. Roberts
- Autonomous Reanimation and Evacuation (AREVA) Research Program, The Geneva Foundation, Brooks City Base, San Antonio, TX 78006, USA; (T.R.R.); (G.T.H.); (A.I.B.)
| | - George T. Harea
- Autonomous Reanimation and Evacuation (AREVA) Research Program, The Geneva Foundation, Brooks City Base, San Antonio, TX 78006, USA; (T.R.R.); (G.T.H.); (A.I.B.)
| | - Christian Wells
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Bryan Teece
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Paramesh Karandikar
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Joseph Urban
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Thomas Risoleo
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Alla Gimbel
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| | - Derek Solt
- Thrombodyne, Inc., Salt Lake City, UT 84103, USA; (D.S.); (S.S.)
| | - Sahar Leazer
- Department of Medicine, F. Edward Hebert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA; (S.L.); (K.K.C.)
| | - Kevin K. Chung
- Department of Medicine, F. Edward Hebert School of Medicine, Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA; (S.L.); (K.K.C.)
| | | | - Andriy I. Batchinsky
- Autonomous Reanimation and Evacuation (AREVA) Research Program, The Geneva Foundation, Brooks City Base, San Antonio, TX 78006, USA; (T.R.R.); (G.T.H.); (A.I.B.)
| | - Jeffrey T. Borenstein
- Draper, Cambridge, MA 02139, USA; (J.S.); (W.L.); (B.C.I.); (D.J.L.); (D.L.); (D.S.); (C.W.); (B.T.); (P.K.); (J.U.); (T.R.); (A.G.)
| |
Collapse
|
13
|
Syed A, Kerdi S, Qamar A. Bioengineering Progress in Lung Assist Devices. Bioengineering (Basel) 2021; 8:89. [PMID: 34203316 PMCID: PMC8301204 DOI: 10.3390/bioengineering8070089] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 05/31/2021] [Accepted: 06/21/2021] [Indexed: 11/17/2022] Open
Abstract
Artificial lung technology is advancing at a startling rate raising hopes that it would better serve the needs of those requiring respiratory support. Whether to assist the healing of an injured lung, support patients to lung transplantation, or to entirely replace native lung function, safe and effective artificial lungs are sought. After 200 years of bioengineering progress, artificial lungs are closer than ever before to meet this demand which has risen exponentially due to the COVID-19 crisis. In this review, the critical advances in the historical development of artificial lungs are detailed. The current state of affairs regarding extracorporeal membrane oxygenation, intravascular lung assists, pump-less extracorporeal lung assists, total artificial lungs, and microfluidic oxygenators are outlined.
Collapse
Affiliation(s)
- Ahad Syed
- Nanofabrication Core Lab, King Abdullah University of Science and Technology, Thuwal 23955-6900, Saudi Arabia;
| | - Sarah Kerdi
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia;
| | - Adnan Qamar
- Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal 23955-6900, Saudi Arabia;
| |
Collapse
|
14
|
Gimbel AA, Hsiao JC, Kim ES, Lewis DJ, Risoleo TF, Urban JN, Borenstein JT. A high gas transfer efficiency microfluidic oxygenator for extracorporeal respiratory assist applications in critical care medicine. Artif Organs 2021; 45:E247-E264. [PMID: 33561881 DOI: 10.1111/aor.13935] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 01/10/2021] [Accepted: 02/05/2021] [Indexed: 12/15/2022]
Abstract
Advances in microfluidics technologies have spurred the development of a new generation of microfluidic respiratory assist devices, constructed using microfabrication techniques capable of producing microchannel dimensions similar to those found in human capillaries and gas transfer films in the same thickness range as the alveolar membrane. These devices have been tested in laboratory settings and in some cases in extracorporeal animal experiments, yet none have been advanced to human clinical studies. A major challenge in the development of microfluidic oxygenators is the difficulty in scaling the technology toward high blood flows necessary to support adult humans; such scaling efforts are often limited by the complexity of the fabrication process and the manner in which blood is distributed in a three-dimensional network of microchannels. Conceptually, a central advantage of microfluidic oxygenators over existing hollow-fiber membrane-based configurations is the potential for shallower channels and thinner gas transfer membranes, features that reduce oxygen diffusion distances, to result in a higher gas transfer efficiency defined as the ratio of the volume of oxygen transferred to the blood per unit time to the active surface area of the gas transfer membrane. If this ratio is not significantly higher than values reported for hollow fiber membrane oxygenators (HFMO), then the expected advantage of the microfluidic approach would not be realized in practice, potentially due to challenges encountered in blood distribution strategies when scaling microfluidic designs to higher flow rates. Here, we report on scaling of a microfluidic oxygenator design from 4 to 92 mL/min blood flow, within an order of magnitude of the flow rate required for neonatal applications. This scaled device is shown to have a gas transfer efficiency higher than any other reported system in the literature, including other microfluidic prototypes and commercial HFMO cartridges. While the high oxygen transfer efficiency is a promising advance toward clinical scaling of a microfluidic architecture, it is accompanied by an excessive blood pressure drop in the circuit, arising from a combination of shallow gas transfer channels and equally shallow distribution manifolds. Therefore, next-generation microfluidic oxygenators will require novel design and fabrication strategies to minimize pressure drops while maintaining very high oxygen transfer efficiencies.
Collapse
Affiliation(s)
| | | | - Ernest S Kim
- Bioengineering Division, Draper, Cambridge, MA, USA
| | | | | | | | | |
Collapse
|
15
|
Blauvelt DG, Abada EN, Oishi P, Roy S. Advances in extracorporeal membrane oxygenator design for artificial placenta technology. Artif Organs 2021; 45:205-221. [PMID: 32979857 PMCID: PMC8513573 DOI: 10.1111/aor.13827] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 07/28/2020] [Accepted: 09/10/2020] [Indexed: 12/15/2022]
Abstract
Extreme prematurity, defined as a gestational age of fewer than 28 weeks, is a significant health problem worldwide. It carries a high burden of mortality and morbidity, in large part due to the immaturity of the lungs at this stage of development. The standard of care for these patients includes support with mechanical ventilation, which exacerbates lung pathology. Extracorporeal life support (ECLS), also called artificial placenta technology when applied to extremely preterm (EPT) infants, offers an intriguing solution. ECLS involves providing gas exchange via an extracorporeal device, thereby doing the work of the lungs and allowing them to develop without being subjected to injurious mechanical ventilation. While ECLS has been successfully used in respiratory failure in full-term neonates, children, and adults, it has not been applied effectively to the EPT patient population. In this review, we discuss the unique aspects of EPT infants and the challenges of applying ECLS to these patients. In addition, we review recent progress in artificial placenta technology development. We then offer analysis on design considerations for successful engineering of a membrane oxygenator for an artificial placenta circuit. Finally, we examine next-generation oxygenators that might advance the development of artificial placenta devices.
Collapse
Affiliation(s)
- David G. Blauvelt
- Department of Pediatrics, University of California, San Francisco, California
| | - Emily N. Abada
- Department of Bioengineering and Therapeutic Sciences, University of California, San Francisco, California
| | - Peter Oishi
- Department of Pediatrics, University of California, San Francisco, California
| | - Shuvo Roy
- Department of Pediatrics, University of California, San Francisco, California
| |
Collapse
|
16
|
Dabaghi M, Rochow N, Saraei N, Fusch G, Monkman S, Da K, Shahin‐Shamsabadi A, Brash JL, Predescu D, Delaney K, Fusch C, Selvaganapathy PR. A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2001860. [PMID: 33173732 PMCID: PMC7610273 DOI: 10.1002/advs.202001860] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/16/2020] [Indexed: 05/19/2023]
Abstract
Premature neonates suffer from respiratory morbidity as their lungs are immature, and current supportive treatment such as mechanical ventilation or extracorporeal membrane oxygenation causes iatrogenic injuries. A non-invasive and biomimetic concept known as the "artificial placenta" (AP) would be beneficial to overcome complications associated with the current respiratory support of preterm infants. Here, a pumpless oxygenator connected to the systemic circulation supports the lung function to relieve respiratory distress. In this paper, the first successful operation of a microfluidic, artificial placenta type neonatal lung assist device (LAD) on a newborn piglet model, which is the closest representation of preterm human infants, is demonstrated. This LAD has high oxygenation capability in both pure oxygen and room air as the sweep gas. The respiratory distress that the newborn piglet is put under during experimentation, repeatedly and over a significant duration of time, is able to be relieved. These findings indicate that this LAD has a potential application as a biomimetic artificial placenta to support the respiratory needs of preterm neonates.
Collapse
Affiliation(s)
| | - Niels Rochow
- Department of PediatricsMcMaster UniversityHamiltonONCanada
- Paracelsus Medical UniversityDepartment of PediatricsUniversity Hospital NurembergNurembergGermany
| | - Neda Saraei
- Department of Mechanical EngineeringMcMaster UniversityHamiltonONCanada
| | - Gerhard Fusch
- Department of PediatricsMcMaster UniversityHamiltonONCanada
| | | | - Kevin Da
- Department of Chemical EngineeringMcMaster UniversityHamiltonONCanada
| | | | - John L. Brash
- School of Biomedical EngineeringMcMaster UniversityHamiltonONCanada
- Department of Chemical EngineeringMcMaster UniversityHamiltonONCanada
| | | | - Kathleen Delaney
- Central Animal Facility DepartmentMcMaster UniversityHamiltonONCanada
| | - Christoph Fusch
- School of Biomedical EngineeringMcMaster UniversityHamiltonONCanada
- Department of PediatricsMcMaster UniversityHamiltonONCanada
- Paracelsus Medical UniversityDepartment of PediatricsUniversity Hospital NurembergNurembergGermany
| | - P. Ravi Selvaganapathy
- School of Biomedical EngineeringMcMaster UniversityHamiltonONCanada
- Department of Mechanical EngineeringMcMaster UniversityHamiltonONCanada
| |
Collapse
|
17
|
New Approaches to Respiratory Assist: Bioengineering an Ambulatory, Miniaturized Bioartificial Lung. ASAIO J 2020; 65:422-429. [PMID: 30044238 DOI: 10.1097/mat.0000000000000841] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Although state-of-the-art treatments of respiratory failure clearly have made some progress in terms of survival in patients suffering from severe respiratory system disorders, such as acute respiratory distress syndrome (ARDS), they failed to significantly improve the quality of life in patients with acute or chronic lung failure, including severe acute exacerbations of chronic obstructive pulmonary disease or ARDS as well. Limitations of standard treatment modalities, which largely rely on conventional mechanical ventilation, emphasize the urgent, unmet clinical need for developing novel (bio)artificial respiratory assist devices that provide extracorporeal gas exchange with a focus on direct extracorporeal CO2 removal from the blood. In this review, we discuss some of the novel concepts and critical prerequisites for such respiratory lung assist devices that can be used with an adequate safety profile, in the intensive care setting, as well as for long-term domiciliary therapy in patients with chronic ventilatory failure. Specifically, we describe some of the pivotal steps, such as device miniaturization, passivation of the blood-contacting surfaces by chemical surface modifications, or endothelial cell seeding, all of which are required for converting current lung assist devices into ambulatory lung assist device for long-term use in critically ill patients. Finally, we also discuss some of the risks and challenges for the long-term use of ambulatory miniaturized bioartificial lungs.
Collapse
|
18
|
Dabaghi M, Saraei N, Fusch G, Rochow N, Brash JL, Fusch C, Selvaganapathy PR. Microfluidic blood oxygenators with integrated hollow chambers for enhanced air exchange from all four sides. J Memb Sci 2020. [DOI: 10.1016/j.memsci.2019.117741] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
19
|
Gehlen DB, De Lencastre Novaes LC, Long W, Ruff AJ, Jakob F, Haraszti T, Chandorkar Y, Yang L, van Rijn P, Schwaneberg U, De Laporte L. Rapid and Robust Coating Method to Render Polydimethylsiloxane Surfaces Cell-Adhesive. ACS APPLIED MATERIALS & INTERFACES 2019; 11:41091-41099. [PMID: 31600051 DOI: 10.1021/acsami.9b16025] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Polydimethylsiloxane (PDMS) is a synthetic material with excellent properties for biomedical applications because of its easy fabrication method, high flexibility, permeability to oxygen, transparency, and potential to produce high-resolution structures in the case of lithography. However, PDMS needs to be modified to support homogeneous cell attachments and spreading. Even though many physical and chemical methods, like plasma treatment or extracellular matrix coatings, have been developed over the last decades to increase cell-surface interactions, these methods are still very time-consuming, often not efficient enough, complex, and can require several treatment steps. To overcome these issues, we present a novel, robust, and fast one-step PDMS coating method using engineered anchor peptides fused to the cell-adhesive peptide sequence (glycine-arginine-glycine-aspartate-serine, GRGDS). The anchor peptide attaches to the PDMS surface predominantly by hydrophobic interactions by simply dipping PDMS in a solution containing the anchor peptide, presenting the GRGDS sequence on the surface available for cell adhesion. The binding performance and kinetics of the anchor peptide to PDMS are characterized, and the coatings are optimized for efficient cell attachment of fibroblasts and endothelial cells. Additionally, the applicability is proven using PDMS-based directional nanotopographic gradients, showing a lower threshold of 5 μm wrinkles for fibroblast alignment.
Collapse
Affiliation(s)
- David B Gehlen
- DWI-Leibniz Institute for Interactive Materials , Forckenbeckstraße 50 , D-52074 Aachen , Germany
| | | | - Wei Long
- Institute of Biotechnology , RWTH Aachen University , Worringerweg 3 , D-52074 Aachen , Germany
| | - Anna Joelle Ruff
- Institute of Biotechnology , RWTH Aachen University , Worringerweg 3 , D-52074 Aachen , Germany
| | - Felix Jakob
- Institute of Biotechnology , RWTH Aachen University , Worringerweg 3 , D-52074 Aachen , Germany
| | - Tamás Haraszti
- DWI-Leibniz Institute for Interactive Materials , Forckenbeckstraße 50 , D-52074 Aachen , Germany
| | - Yashoda Chandorkar
- DWI-Leibniz Institute for Interactive Materials , Forckenbeckstraße 50 , D-52074 Aachen , Germany
| | - Liangliang Yang
- University Medical Center Groningen , Department of Biomedical Engineering , FB40 , 9713 AV Groningen , The Netherlands
| | - Patrick van Rijn
- University Medical Center Groningen , Department of Biomedical Engineering , FB40 , 9713 AV Groningen , The Netherlands
| | - Ulrich Schwaneberg
- Institute of Biotechnology , RWTH Aachen University , Worringerweg 3 , D-52074 Aachen , Germany
| | - Laura De Laporte
- DWI-Leibniz Institute for Interactive Materials , Forckenbeckstraße 50 , D-52074 Aachen , Germany
- Institute for Technical and Macromolecular Chemistry , RWTH Aachen University , Worringerweg 1-2 , D-52074 Aachen , Germany
| |
Collapse
|
20
|
Dabaghi M, Saraei N, Fusch G, Rochow N, Brash JL, Fusch C, Ravi Selvaganapathy P. An ultra-thin, all PDMS-based microfluidic lung assist device with high oxygenation capacity. BIOMICROFLUIDICS 2019; 13:034116. [PMID: 31263515 PMCID: PMC6597343 DOI: 10.1063/1.5091492] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Accepted: 06/11/2019] [Indexed: 05/06/2023]
Abstract
Preterm neonates with immature lungs require a lung assist device (LAD) to maintain oxygen saturation at normal levels. Over the last decade, microfluidic blood oxygenators have attracted considerable interest due to their ability to incorporate unique biomimetic design and to oxygenate in a physiologically relevant manner. Polydimethylsiloxane (PDMS) has become the main material choice for these kinds of devices due to its high gas permeability. However, fabrication of large area ultrathin microfluidic devices that can oxygenate sufficient blood volumes at clinically relevant flow rates, entirely made of PDMS, have been difficult to achieve primarily due to failure associated with stiction of thin PDMS membranes to each other at undesired locations during assembly. Here, we demonstrate the use of a modified fabrication process to produce large area ultrathin oxygenators entirely made of PDMS and robust enough to withstand the hydraulic conditions that are encountered physiologically. We also demonstrate that a LAD assembled from these ultrathin double-sided microfluidic blood oxygenators can increase the oxygen saturation level by 30% at a flow rate of 30 ml/min and a pressure drop of 21 mm Hg in room air which is adequate for 1 kg preterm neonates. In addition, we demonstrated that our LAD could withstand high blood flow rate of 150 ml/min and increase oxygen saturation by 26.7% in enriched oxygen environment which is the highest gas exchange reported so far by any microfluidic-based blood oxygenators. Such performance makes this LAD suitable to provide support to 1 kg neonate suffering from respiratory distress syndrome.
Collapse
Affiliation(s)
| | - Neda Saraei
- Department of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Gerhard Fusch
- Department of Pediatrics, McMaster University, Hamilton, Ontario L8S 4K1, Canada
| | - Niels Rochow
- Department of Pediatrics, McMaster University, Hamilton, Ontario L8S 4K1, Canada
| | | | | | | |
Collapse
|
21
|
Thompson AJ, Ma LJ, Plegue TJ, Potkay JA. Design Analysis and Optimization of a Single-Layer PDMS Microfluidic Artificial Lung. IEEE Trans Biomed Eng 2019; 66:1082-1093. [DOI: 10.1109/tbme.2018.2866782] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
22
|
Zhang F, Tian C, Liu W, Wang K, Wei Y, Wang H, Wang J, Liu S. Determination of Benzopyrene-Induced Lung Inflammatory and Cytotoxic Injury in a Chemical Gradient-Integrated Microfluidic Bronchial Epithelium System. ACS Sens 2018; 3:2716-2725. [PMID: 30507116 DOI: 10.1021/acssensors.8b01370] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Environmental pollution is one of the largest sources responsible for human diseases and premature death worldwide. However, the methodological development of a spatiotemporally controllable and high-throughput investigation of the environmental pollution-induced biological injury events is still being explored. In this study, we describe a chemical gradient generator-aided microfluidic cell system for the dynamic study of representative environmental pollutant-induced bronchial epithelium injury in a throughput manner. We demonstrated the stability and reliability of operation-optimized microfluidic system for precise and long-term chemical gradient production. We also performed a microenvironment-controlled microfluidic bronchial epithelium construction with high viability and structure integration. Moreover, on-chip investigation of bronchial epithelium injury by benzopyrene stimulation with various concentrations can be carried out in the single device. The varying bronchial inflammatory and cytotoxic responses were temporally monitored and measured based on the well-established system. The benzopyrene directionally led the bronchial epithelium to present observable cell shrinkage, cytoskeleton disintegration, Caspase-3 activation, overproduction of reactive oxygen species, and various inflammatory cytokine (TNF-α, IL-6, and IL-8) secretion, suggesting its significant inflammatory and cytotoxic effects on respiratory system. We believe the microfluidic advancement has potential applications in the fields of environmental monitoring, tissue engineering, and pharmaceutical development.
Collapse
Affiliation(s)
- Fen Zhang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Chang Tian
- College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Wenming Liu
- School of Basic Medical Science, Central South University, Changsha, Hunan 410013, China
- College of Chemistry and Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Kan Wang
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Yuanqing Wei
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Huaisheng Wang
- Department of Chemistry, Liaocheng University, Liaocheng, Shandong 252059, China
| | - Jinyi Wang
- College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi 712100, China
- College of Chemistry and Pharmacy, Northwest A&F University, Yangling, Shaanxi 712100, China
| | - Songqin Liu
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|
23
|
Dabaghi M, Saraei N, Fusch G, Rochow N, Brash JL, Fusch C, Selvaganapathy PR. An ultra-thin highly flexible microfluidic device for blood oxygenation. LAB ON A CHIP 2018; 18:3780-3789. [PMID: 30421770 DOI: 10.1039/c8lc01083h] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Many neonates who are born premature suffer from respiratory distress syndrome (RDS) for which mechanical ventilation and an extracorporeal membrane oxygenation (ECMO) device are used in treatment. However, the use of these invasive techniques results in higher risk of complications like bronchopulmonary dysplasia or requires surgery to gain vascular access. An alternative biomimetic approach is to use the umbilical cord as a vascular access and to connect a passive device to the baby that functions like a placenta. This concept, known as the artificial placenta, provides enough oxygenation and causes minimal distress or complications. Herein, we have developed a new artificial placenta-type microfluidic blood oxygenator (APMBO) with high gas exchange, low priming volume and low hydraulic resistance such that it can be operated only by pressure differential provided by the baby's heart. Mimicking the placenta, we have made our new device ultra-thin and flexible so that it can be folded into a desired shape without losing its capability for gas exchange and achieve a compact form factor. The ability to fold allowed optimization of connectors and reduced the overall priming volume to the sub-milliliter range while achieving a high oxygen uptake which would be sufficient for preterm neonates with a birth-weight of around 0.5 kg.
Collapse
|
24
|
Dabaghi M, Fusch G, Saraei N, Rochow N, Brash JL, Fusch C, Ravi Selvaganapathy P. An artificial placenta type microfluidic blood oxygenator with double-sided gas transfer microchannels and its integration as a neonatal lung assist device. BIOMICROFLUIDICS 2018; 12:044101. [PMID: 30867861 PMCID: PMC6404930 DOI: 10.1063/1.5034791] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Accepted: 06/05/2018] [Indexed: 05/22/2023]
Abstract
Preterm neonates suffering from respiratory distress syndrome require assistive support in the form of mechanical ventilation or extracorporeal membrane oxygenation, which may lead to long-term complications or even death. Here, we describe a high performance artificial placenta type microfluidic oxygenator, termed as a double-sided single oxygenator unit (dsSOU), which combines microwire stainless-steel mesh reinforced gas permeable membranes on both sides of a microchannel network, thereby significantly reducing the diffusional resistance to oxygen uptake as compared to the previous single-sided oxygenator designs. The new oxygenator is designed to be operated in a pumpless manner, perfused solely due to the arterio-venous pressure difference in a neonate and oxygenate blood through exposure directly to ambient atmosphere without any air or oxygen pumping. The best performing dsSOUs showed up to ∼343% improvement in oxygen transfer compared to a single-sided SOU (ssSOU) with the same height. Later, the dsSOUs were optimized and integrated to build a lung assist device (LAD) that could support the oxygenation needs for a 1-2 kg neonate under clinically relevant conditions for the artificial placenta, namely, flow rates ranging from 10 to 60 ml/min and a pressure drop of 10-60 mmHg. The LAD provided an oxygen uptake of 0.78-2.86 ml/min, which corresponded to the increase in oxygen saturation from 57 ± 1% to 93%-100%, under pure oxygen environment. This microfluidic lung assist device combines elegant design with new microfabrication methods to develop a pumpless, microfluidic blood oxygenator that is capable of supporting 30% of the oxygen needs of a pre-term neonate.
Collapse
Affiliation(s)
| | - Gerhard Fusch
- Department of Pediatrics, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Neda Saraei
- Department of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Niels Rochow
- Department of Pediatrics, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | | | | | | |
Collapse
|
25
|
Malankowska M, Martins C, Rho H, Neves L, Tiggelaar R, Crespo J, Pina M, Mallada R, Gardeniers H, Coelhoso I. Microfluidic devices as gas – Ionic liquid membrane contactors for CO2 removal from anaesthesia gases. J Memb Sci 2018. [DOI: 10.1016/j.memsci.2017.09.065] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
26
|
Matharoo H, Dabaghi M, Rochow N, Fusch G, Saraei N, Tauhiduzzaman M, Veldhuis S, Brash J, Fusch C, Selvaganapathy PR. Steel reinforced composite silicone membranes and its integration to microfluidic oxygenators for high performance gas exchange. BIOMICROFLUIDICS 2018; 12:014107. [PMID: 29375728 PMCID: PMC5764751 DOI: 10.1063/1.5014028] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Accepted: 01/02/2018] [Indexed: 05/19/2023]
Abstract
Respiratory distress syndrome (RDS) is one of the main causes of fatality in newborn infants, particularly in neonates with low birth-weight. Commercial extracorporeal oxygenators have been used for low-birth-weight neonates in neonatal intensive care units. However, these oxygenators require high blood volumes to prime. In the last decade, microfluidics oxygenators using enriched oxygen have been developed for this purpose. Some of these oxygenators use thin polydimethylsiloxane (PDMS) membranes to facilitate gas exchange between the blood flowing in the microchannels and the ambient air outside. However, PDMS is elastic and the thin membranes exhibit significant deformation and delamination under pressure which alters the architecture of the devices causing poor oxygenation or device failure. Therefore, an alternate membrane with high stability, low deformation under pressure, and high gas exchange was desired. In this paper, we present a novel composite membrane consisting of an ultra-thin stainless-steel mesh embedded in PDMS, designed specifically for a microfluidic single oxygenator unit (SOU). In comparison to homogeneous PDMS membranes, this composite membrane demonstrated high stability, low deformation under pressure, and high gas exchange. In addition, a new design for oxygenator with sloping profile and tapered inlet configuration has been introduced to achieve the same gas exchange at lower pressure drops. SOUs were tested by bovine blood to evaluate gas exchange properties. Among all tested SOUs, the flat design SOU with composite membrane has the highest oxygen exchange of 40.32 ml/min m2. The superior performance of the new device with composite membrane was demonstrated by constructing a lung assist device (LAD) with a low priming volume of 10 ml. The LAD was achieved by the oxygen uptake of 0.48-0.90 ml/min and the CO2 release of 1.05-2.27 ml/min at blood flow rates ranging between 8 and 48 ml/min. This LAD was shown to increase the oxygen saturation level by 25% at the low pressure drop of 29 mm Hg. Finally, a piglet was used to test the gas exchange capacity of the LAD in vivo. The animal experiment results were in accordance with in-vitro results, which shows that the LAD is capable of providing sufficient gas exchange at a blood flow rate of ∼24 ml/min.
Collapse
Affiliation(s)
- Harpreet Matharoo
- Department of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | | | - Niels Rochow
- Department of Pediatrics, McMaster University, Hamilton, Ontario L8S 4K1, Canada
| | - Gerhard Fusch
- Department of Pediatrics, McMaster University, Hamilton, Ontario L8S 4K1, Canada
| | - Neda Saraei
- Department of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Mohammed Tauhiduzzaman
- Department of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | - Stephen Veldhuis
- Department of Mechanical Engineering, McMaster University, Hamilton, Ontario L8S 4L7, Canada
| | | | | | | |
Collapse
|
27
|
Zilberman-Rudenko J, Sylman JL, Garland KS, Puy C, Wong AD, Searson PC, McCarty OJT. Utility of microfluidic devices to study the platelet-endothelium interface. Platelets 2017; 28:449-456. [PMID: 28358586 DOI: 10.1080/09537104.2017.1280600] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The integration of biomaterials and understanding of vascular biology has led to the development of perfusable endothelialized flow models, which have been used as valuable tools to study the platelet-endothelium interface under shear. In these models, the parameters of geometry, compliance, biorheology, and cellular complexity are varied to recapitulate the physical biology of platelet recruitment and activation under physiologically relevant conditions of blood flow. In this review, we summarize the mechanistic insights learned from perfusable microvessel models and discuss the potential utility as well as challenges of endothelialized microfluidic devices to study platelet function in the bloodstream in vitro.
Collapse
Affiliation(s)
- Jevgenia Zilberman-Rudenko
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA
| | - Joanna L Sylman
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA
| | - Kathleen S Garland
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA.,c Division of Pediatric Hematology/Oncology , Oregon Health and Science University , Portland , OR , USA
| | - Cristina Puy
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA
| | - Andrew D Wong
- b Institute for Nanobiotechnology (INBT) , Johns Hopkins University , Baltimore , MD , USA.,d Department of Materials Science and Engineering , Johns Hopkins University , Baltimore , MD , USA
| | - Peter C Searson
- b Institute for Nanobiotechnology (INBT) , Johns Hopkins University , Baltimore , MD , USA.,d Department of Materials Science and Engineering , Johns Hopkins University , Baltimore , MD , USA
| | - Owen J T McCarty
- a Biomedical Engineering, School of Medicine , Oregon Health and Science University , Portland , OR , USA.,c Division of Pediatric Hematology/Oncology , Oregon Health and Science University , Portland , OR , USA
| |
Collapse
|
28
|
Thompson AJ, Marks LH, Goudie MJ, Rojas-Pena A, Handa H, Potkay JA. A small-scale, rolled-membrane microfluidic artificial lung designed towards future large area manufacturing. BIOMICROFLUIDICS 2017; 11:024113. [PMID: 28798849 PMCID: PMC5533476 DOI: 10.1063/1.4979676] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Accepted: 03/22/2017] [Indexed: 05/22/2023]
Abstract
Artificial lungs have been used in the clinic for multiple decades to supplement patient pulmonary function. Recently, small-scale microfluidic artificial lungs (μAL) have been demonstrated with large surface area to blood volume ratios, biomimetic blood flow paths, and pressure drops compatible with pumpless operation. Initial small-scale microfluidic devices with blood flow rates in the μl/min to ml/min range have exhibited excellent gas transfer efficiencies; however, current manufacturing techniques may not be suitable for scaling up to human applications. Here, we present a new manufacturing technology for a microfluidic artificial lung in which the structure is assembled via a continuous "rolling" and bonding procedure from a single, patterned layer of polydimethyl siloxane (PDMS). This method is demonstrated in a small-scale four-layer device, but is expected to easily scale to larger area devices. The presented devices have a biomimetic branching blood flow network, 10 μm tall artificial capillaries, and a 66 μm thick gas transfer membrane. Gas transfer efficiency in blood was evaluated over a range of blood flow rates (0.1-1.25 ml/min) for two different sweep gases (pure O2, atmospheric air). The achieved gas transfer data closely follow predicted theoretical values for oxygenation and CO2 removal, while pressure drop is marginally higher than predicted. This work is the first step in developing a scalable method for creating large area microfluidic artificial lungs. Although designed for microfluidic artificial lungs, the presented technique is expected to result in the first manufacturing method capable of simply and easily creating large area microfluidic devices from PDMS.
Collapse
Affiliation(s)
| | - L H Marks
- VA Ann Arbor Healthcare System, Ann Arbor, Michigan 48105, USA
| | - M J Goudie
- College of Engineering, University of Georgia, Athens, Georgia 30602, USA
| | - A Rojas-Pena
- Department of Surgery, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - H Handa
- College of Engineering, University of Georgia, Athens, Georgia 30602, USA
| | | |
Collapse
|
29
|
Gimbel AA, Flores E, Koo A, García-Cardeña G, Borenstein JT. Development of a biomimetic microfluidic oxygen transfer device. LAB ON A CHIP 2016; 16:3227-34. [PMID: 27411972 PMCID: PMC4987252 DOI: 10.1039/c6lc00641h] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Blood oxygenators provide crucial life support for patients suffering from respiratory failure, but their use is severely limited by the complex nature of the blood circuit and by complications including bleeding and clotting. We have fabricated and tested a multilayer microfluidic blood oxygenation prototype designed to have a lower blood prime volume and improved blood circulation relative to current hollow fiber cartridge oxygenators. Here we address processes for scaling the device toward clinically relevant oxygen transfer rates while maintaining a low prime volume of blood in the device, which is required for clinical applications in cardiopulmonary support and ultimately for chronic use. Approaches for scaling the device toward clinically relevant gas transfer rates, both by expanding the active surface area of the network of blood microchannels in a planar layer and by increasing the number of microfluidic layers stacked together in a three-dimensional device are addressed. In addition to reducing prime volume and enhancing gas transfer efficiency, the geometric properties of the microchannel networks are designed to increase device safety by providing a biomimetic and physiologically realistic flow path for the blood. Safety and hemocompatibility are also influenced by blood-surface interactions within the device. In order to further enhance device safety and hemocompatibility, we have demonstrated successful coating of the blood flow pathways with human endothelial cells, in order to confer the ability of the endothelium to inhibit coagulation and thrombus formation. Blood testing results provide confirmation of fibrin clot formation in non-endothelialized devices, while negligible clot formation was documented in cell-coated devices. Gas transfer testing demonstrates that the endothelial lining does not reduce the transfer efficiency relative to acellular devices. This process of scaling the microfluidic architecture and utilizing autologous cells to line the channels and mitigate coagulation represents a promising avenue for therapy for patients suffering from a range of acute and chronic lung diseases.
Collapse
Affiliation(s)
- A A Gimbel
- Department of Biomedical Engineering, The Charles Stark Draper Laboratory, Inc., Cambridge, MA 02139, USA.
| | - E Flores
- Department of Biomedical Engineering, The Charles Stark Draper Laboratory, Inc., Cambridge, MA 02139, USA.
| | - A Koo
- Laboratory for Systems Biology, Center for Excellence in Vascular Biology, Department of Pathology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA
| | - G García-Cardeña
- Laboratory for Systems Biology, Center for Excellence in Vascular Biology, Department of Pathology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA
| | - J T Borenstein
- Department of Biomedical Engineering, The Charles Stark Draper Laboratory, Inc., Cambridge, MA 02139, USA.
| |
Collapse
|
30
|
Construction of Large-Volume Tissue Mimics with 3D Functional Vascular Networks. PLoS One 2016; 11:e0156529. [PMID: 27228079 PMCID: PMC4882012 DOI: 10.1371/journal.pone.0156529] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2015] [Accepted: 05/16/2016] [Indexed: 11/19/2022] Open
Abstract
We used indirect stereolithography (SL) to form inner-layered fluidic networks in a porous scaffold by introducing a hydrogel barrier on the luminal surface, then seeded the networks separately with human umbilical vein endothelial cells and human lung fibroblasts to form a tissue mimic containing vascular networks. The artificial vascular networks provided channels for oxygen transport, thus reducing the hypoxic volume and preventing cell death. The endothelium of the vascular networks significantly retarded the occlusion of channels during whole-blood circulation. The tissue mimics have the potential to be used as an in vitro platform to examine the physiologic and pathologic phenomena through vascular architecture.
Collapse
|
31
|
Potkay JA. Reply to the 'Comment on "The promise of microfluidic artificial lungs"' by G. Wagner, A. Kaesler, U. Steinseifer, T. Schmitz-Rode and J. Arens, Lab Chip, 2016, 16. LAB ON A CHIP 2016; 16:1274-1277. [PMID: 26957040 DOI: 10.1039/c6lc00221h] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This response explores and discusses the critiques of Wagner et al. in their "Comment on 'The promise of microfluidic artificial lungs' by Joseph A. Potkay, Lab Chip, 2014, 14, 4122-4138".
Collapse
Affiliation(s)
- Joseph A Potkay
- VA Ann Arbor Healthcare System, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA.
| |
Collapse
|
32
|
Wagner G, Kaesler A, Steinseifer U, Schmitz-Rode T, Arens J. Comment on "The promise of microfluidic artificial lungs" by J. A. Potkay, Lab Chip, 2014, 14, 4122-4138. LAB ON A CHIP 2016; 16:1272-1273. [PMID: 26956695 DOI: 10.1039/c5lc01508a] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This comment on an article that appeared in this journal (Potkay, Lab Chip, 2014, 14, 4122-4138) presents an alternative view on the feasibility and clinical application of current microfluidic artificial lungs.
Collapse
Affiliation(s)
- Georg Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| | - Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| |
Collapse
|
33
|
|
34
|
Microfluidic Organ/Body-on-a-Chip Devices at the Convergence of Biology and Microengineering. SENSORS 2015; 15:31142-70. [PMID: 26690442 PMCID: PMC4721768 DOI: 10.3390/s151229848] [Citation(s) in RCA: 84] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2015] [Revised: 11/16/2015] [Accepted: 12/04/2015] [Indexed: 12/24/2022]
Abstract
Recent advances in biomedical technologies are mostly related to the convergence of biology with microengineering. For instance, microfluidic devices are now commonly found in most research centers, clinics and hospitals, contributing to more accurate studies and therapies as powerful tools for drug delivery, monitoring of specific analytes, and medical diagnostics. Most remarkably, integration of cellularized constructs within microengineered platforms has enabled the recapitulation of the physiological and pathological conditions of complex tissues and organs. The so-called “organ-on-a-chip” technology, which represents a new avenue in the field of advanced in vitro models, with the potential to revolutionize current approaches to drug screening and toxicology studies. This review aims to highlight recent advances of microfluidic-based devices towards a body-on-a-chip concept, exploring their technology and broad applications in the biomedical field.
Collapse
|
35
|
Prakash YS, Tschumperlin DJ, Stenmark KR. Coming to terms with tissue engineering and regenerative medicine in the lung. Am J Physiol Lung Cell Mol Physiol 2015; 309:L625-38. [PMID: 26254424 DOI: 10.1152/ajplung.00204.2015] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Accepted: 08/04/2015] [Indexed: 01/10/2023] Open
Abstract
Lung diseases such as emphysema, interstitial fibrosis, and pulmonary vascular diseases cause significant morbidity and mortality, but despite substantial mechanistic understanding, clinical management options for them are limited, with lung transplantation being implemented at end stages. However, limited donor lung availability, graft rejection, and long-term problems after transplantation are major hurdles to lung transplantation being a panacea. Bioengineering the lung is an exciting and emerging solution that has the ultimate aim of generating lung tissues and organs for transplantation. In this article we capture and review the current state of the art in lung bioengineering, from the multimodal approaches, to creating anatomically appropriate lung scaffolds that can be recellularized to eventually yield functioning, transplant-ready lungs. Strategies for decellularizing mammalian lungs to create scaffolds with native extracellular matrix components vs. de novo generation of scaffolds using biocompatible materials are discussed. Strengths vs. limitations of recellularization using different cell types of various pluripotency such as embryonic, mesenchymal, and induced pluripotent stem cells are highlighted. Current hurdles to guide future research toward achieving the clinical goal of transplantation of a bioengineered lung are discussed.
Collapse
Affiliation(s)
- Y S Prakash
- Department of Anesthesiology, Mayo Clinic, Rochester, Minnesota; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota;
| | - Daniel J Tschumperlin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota; Division of Pulmonary Medicine, Mayo Clinic, Rochester, Minnesota; and
| | - Kurt R Stenmark
- Department of Pediatrics, University of Colorado, Aurora, Colorado
| |
Collapse
|
36
|
Lo JH, Bassett EK, Penson EJN, Hoganson DM, Vacanti JP. Gas Transfer in Cellularized Collagen-Membrane Gas Exchange Devices. Tissue Eng Part A 2015; 21:2147-55. [PMID: 26020102 DOI: 10.1089/ten.tea.2014.0369] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
Chronic lower respiratory disease is highly prevalent in the United States, and there remains a need for alternatives to lung transplant for patients who progress to end-stage lung disease. Portable or implantable gas oxygenators based on microfluidic technologies can address this need, provided they operate both efficiently and biocompatibly. Incorporating biomimetic materials into such devices can help replicate native gas exchange function and additionally support cellular components. In this work, we have developed microfluidic devices that enable blood gas exchange across ultra-thin collagen membranes (as thin as 2 μm). Endothelial, stromal, and parenchymal cells readily adhere to these membranes, and long-term culture with cellular components results in remodeling, reflected by reduced membrane thickness. Functionally, acellular collagen-membrane lung devices can mediate effective gas exchange up to ∼288 mL/min/m(2) of oxygen and ∼685 mL/min/m(2) of carbon dioxide, approaching the gas exchange efficiency noted in the native lung. Testing several configurations of lung devices to explore various physical parameters of the device design, we concluded that thinner membranes and longer gas exchange distances result in improved hemoglobin saturation and increases in pO2. However, in the design space tested, these effects are relatively small compared to the improvement in overall oxygen and carbon dioxide transfer by increasing the blood flow rate. Finally, devices cultured with endothelial and parenchymal cells achieved similar gas exchange rates compared with acellular devices. Biomimetic blood oxygenator design opens the possibility of creating portable or implantable microfluidic devices that achieve efficient gas transfer while also maintaining physiologic conditions.
Collapse
Affiliation(s)
- Justin H Lo
- 1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.,2 Harvard Medical School , Boston, Massachusetts.,3 Harvard-MIT Division of Health Sciences and Technology , Cambridge, Massachusetts
| | - Erik K Bassett
- 1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts
| | - Elliot J N Penson
- 1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts
| | - David M Hoganson
- 1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts
| | - Joseph P Vacanti
- 1 Department of Surgery, Center for Regenerative Medicine , Massachusetts General Hospital, Boston, Massachusetts.,2 Harvard Medical School , Boston, Massachusetts
| |
Collapse
|
37
|
Caplin JD, Granados NG, James MR, Montazami R, Hashemi N. Microfluidic Organ-on-a-Chip Technology for Advancement of Drug Development and Toxicology. Adv Healthc Mater 2015; 4:1426-50. [PMID: 25820344 DOI: 10.1002/adhm.201500040] [Citation(s) in RCA: 132] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 02/18/2015] [Indexed: 01/09/2023]
Abstract
In recent years, the exploitation of phenomena surrounding microfluidics has seen an increase in popularity, as researchers have found a way to use their unique properties to create superior design alternatives. One such application is representing the properties and functions of different organs on a microscale chip for the purpose of drug testing or tissue engineering. With the introduction of "organ-on-a-chip" systems, researchers have proposed various methods on various organ-on-a-chip systems to mimic their in vivo counterparts. In this article, a systematic approach is taken to review current technologies pertaining to organ-on-a-chip systems. Design processes with attention to the particular instruments, cells, and materials used are presented.
Collapse
Affiliation(s)
- Jeremy D. Caplin
- Department of Mechanical Engineering; Iowa State University; Ames IA 50011 USA
| | - Norma G. Granados
- Department of Mechanical Engineering; Iowa State University; Ames IA 50011 USA
| | - Myra R. James
- Department of Mechanical Engineering; Iowa State University; Ames IA 50011 USA
| | - Reza Montazami
- Department of Mechanical Engineering; Iowa State University; Ames IA 50011 USA
- Center for Advanced Host Defense Immunobiotics and Translational Comparative Medicine; Iowa State University; Ames IA 50011 USA
| | - Nastaran Hashemi
- Department of Mechanical Engineering; Iowa State University; Ames IA 50011 USA
- Center for Advanced Host Defense Immunobiotics and Translational Comparative Medicine; Iowa State University; Ames IA 50011 USA
| |
Collapse
|
38
|
Kovach KM, LaBarbera MA, Moyer MC, Cmolik BL, van Lunteren E, Sen Gupta A, Capadona JR, Potkay JA. In vitro evaluation and in vivo demonstration of a biomimetic, hemocompatible, microfluidic artificial lung. LAB ON A CHIP 2015; 15:1366-75. [PMID: 25591918 DOI: 10.1039/c4lc01284d] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
Despite the promising potential of microfluidic artificial lungs, current designs suffer from short functional lifetimes due to surface chemistry and blood flow patterns that act to reduce hemocompatibility. Here, we present the first microfluidic artificial lung featuring a hemocompatible surface coating and a biomimetic blood path. The polyethylene-glycol (PEG) coated microfluidic lung exhibited a significantly improved in vitro lifetime compared to uncoated controls as well as consistent and significantly improved gas exchange over the entire testing period. Enabled by our hemocompatible PEG coating, we additionally describe the first extended (3 h) in vivo demonstration of a microfluidic artificial lung.
Collapse
Affiliation(s)
- K M Kovach
- Advanced Platform Technology Center (APT Center), Louis Stokes Cleveland VA Medical Center, Cleveland, OH 44106, USA
| | | | | | | | | | | | | | | |
Collapse
|
39
|
Abstract
RATIONALE Much recent interest in lung bioengineering by pulmonary investigators, industry and the organ transplant field has seen a rapid growth of bioreactor development ranging from the microfluidic scale to the human-sized whole lung systems. A comprehension of the findings from these models is needed to provide the basis for further bioreactor development. OBJECTIVE The goal was to comprehensively review the current state of bioreactor development for the lung. METHODS A search using PubMed was done for published, peer-reviewed papers using the keywords "lung" AND "bioreactor" or "bioengineering" or "tissue engineering" or "ex vivo perfusion". MAIN RESULTS Many new bioreactors ranging from the microfluidic scale to the human-sized whole lung systems have been developed by both academic and commercial entities. Microfluidic, lung-mimic and lung slice cultures have the advantages of cost-efficiency and high throughput analyses ideal for pharmaceutical and toxicity studies. Perfused/ventilated rodent whole lung systems can be adapted for mid-throughput studies of lung stem/progenitor cell development, cell behavior, understanding and treating lung injury and for preliminary work that can be translated to human lung bioengineering. Human-sized ex vivo whole lung bioreactors incorporating perfusion and ventilation are amenable to automation and have been used for whole lung decellularization and recellularization. Clinical scale ex vivo lung perfusion systems have been developed for lung preservation and reconditioning and are currently being evaluated in clinical trials. CONCLUSIONS Significant advances in bioreactors for lung engineering have been made at both the microfluidic and the macro scale. The most advanced are closed systems that incorporate pressure-controlled perfusion and ventilation and are amenable to automation. Ex vivo lung perfusion systems have advanced to clinical trials for lung preservation and reconditioning. The biggest challenges that lie ahead for lung bioengineering can only be overcome by future advances in technology that solve the problems of cell production and tissue incorporation.
Collapse
Affiliation(s)
- Angela Panoskaltsis-Mortari
- Departments of Pediatrics and Medicine; Blood and Marrow Transplant Program; Pulmonary, Allergy, Critical Care and Sleep Medicine, University of Minnesota, Minneapolis, MN, 55455, U.S.A
| |
Collapse
|
40
|
Abstract
Microfluidic or microchannel artificial lungs promise to enable a new class of truly portable, therapeutic artificial lungs through feature sizes and blood channel designs that closely mimic those found in their natural counterpart. These new artificial lungs could potentially: 1) have surface areas and priming volumes that are a fraction of current technologies thereby decreasing device size and reducing the foreign body response; 2) contain blood flow networks in which cells and platelets experience pressures, shear stresses, and branching angles that copy those in the human lung thereby improving biocompatibility; 3) operate efficiently with room air, eliminating the need for gas cylinders and complications associated with hyperoxemia; 4) exhibit biomimetic hydraulic resistances, enabling operation with natural pressures and eliminating the need for blood pumps; and, 5) provide increased gas exchange capacity enabling respiratory support for active patients. This manuscript reviews recent research efforts in microfluidic artificial lungs targeted at achieving the advantages above, investigates the ultimate performance and scaling limits of these devices using a proven mathematical model, and discusses the future challenges that must be overcome in order for microfluidic artificial lungs to be applied in the clinic. If all of these promising advantages are realized and the remaining challenges are met, microfluidic artificial lungs could revolutionize the field of pulmonary rehabilitation.
Collapse
|
41
|
Abstract
INTRODUCTION OR BACKGROUND The incidence of chronic lung disease is increasing worldwide due to the spread of risk factors and ageing population. An important advance in treatment would be the development of a bioartificial lung where the blood-gas exchange surface is manufactured from a synthetic or natural scaffold material that is seeded with the appropriate stem or progenitor cells to mimic the functional tissue of the natural lung. SOURCES OF DATA Articles relating to bioartificial lungs were sourced through PubMed and ISI Web of Knowledge. AREAS OF AGREEMENT There is a consensus that advances in bioartificial lung engineering will be beneficial to patients with chronic lung failure. Ultimate success will require the concerted efforts of researchers drawn from a broad range of disciplines, including clinicians, cell biologists, materials scientists and engineers. AREAS OF CONTROVERSY As a source of cells for use in bioartificial lungs it is proposed to use human embryonic stem cells; however, there are ethical and safety concerns regarding the use of these cells. GROWING POINTS There is a need to identify the optimum strategies for differentiating progenitor cells into functional lung cells; a need to better understand cell-biomaterial/ECM interactions and a need to understand how to harness the body's natural capacity to regenerate the lung. AREAS TIMELY FOR DEVELOPING RESEARCH Biomaterial technologies for recreating the natural lung ECM and architecture need further development. Mathematical modelling techniques should be developed for determining optimal scaffold seeding strategies and predicting gas exchange performance.
Collapse
Affiliation(s)
- Greg Lemon
- Department of Clinical Science, Intervention and Technology (CLINTEC), Advanced Center for Translational Regenerative Medicine (ACTREM), Karolinska Institutet, Stockholm, Sweden
| | - Mei Ling Lim
- Department of Clinical Science, Intervention and Technology (CLINTEC), Advanced Center for Translational Regenerative Medicine (ACTREM), Karolinska Institutet, Stockholm, Sweden Division of Ear, Nose and Throat, Karolinska University Hospital, Stockholm, Sweden
| | - Fatemeh Ajalloueian
- Department of Clinical Science, Intervention and Technology (CLINTEC), Advanced Center for Translational Regenerative Medicine (ACTREM), Karolinska Institutet, Stockholm, Sweden
| | - Paolo Macchiarini
- Department of Clinical Science, Intervention and Technology (CLINTEC), Advanced Center for Translational Regenerative Medicine (ACTREM), Karolinska Institutet, Stockholm, Sweden Division of Ear, Nose and Throat, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
42
|
Hoganson DM, Gazit AZ, Boston US, Sweet SC, Grady RM, Huddleston CB, Eghtesady P. Paracorporeal lung assist devices as a bridge to recovery or lung transplantation in neonates and young children. J Thorac Cardiovasc Surg 2013; 147:420-6. [PMID: 24199759 DOI: 10.1016/j.jtcvs.2013.08.078] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2013] [Revised: 08/16/2013] [Accepted: 08/27/2013] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To evaluate paracorporeal lung assist devices to treat neonates and children with decompensated respiratory failure as a bridge to recovery or lung transplantation. METHODS One neonate (23 days old) and 3 young children (aged 2, 9, and 23 months) presented with primary lung disease with pulmonary hypertension, including alveolar capillary dysplasia in 2 and right pulmonary hypoplasia and primary pulmonary hypertension in 1. The patients were listed for lung transplantation but decompensated and required extracorporeal membrane oxygenation (ECMO). The patients were transitioned from ECMO to a pumpless paracorporeal lung assist device (Maquet Quadrox-iD oxygenator in 3, Novalung in 1) with inflow from the pulmonary artery and return to the left atrium. RESULTS The patients were weaned from ECMO and supported by the device for 44 ± 29 days (range, 5-74). Three patients were extubated while supported by the device (after 9, 15, and 72 days). One patient was bridged to lung transplant (9 months old, with alveolar capillary dysplasia, supported 5 days). One patient was bridged to recovery with maximal medical therapy (23 months old, with primary pulmonary hypertension, supported 23 days). Two patients died while awaiting a suitable lung donor after a support time of 54 and 72 days. CONCLUSIONS Pediatric patients bridged from ECMO to lung transplantation have poor results. An alternative method for longer term respiratory support was necessary as a bridge for these patients. The use of a paracorporeal lung assist device successfully supported 4 patients to recovery, lung transplantation, or past the average wait time for pediatric donor lungs (27 days). This therapy has the potential to bridge children with decompensated respiratory failure to lung transplantation.
Collapse
Affiliation(s)
- David M Hoganson
- Division of Cardiothoracic Surgery, Department of Surgery, St Louis Children's Hospital and Washington University, St Louis, Mo
| | - Avihu Z Gazit
- Division of Critical Care, St Louis Children's Hospital and Washington University, St Louis, Mo; Division of Cardiology, St Louis Children's Hospital and Washington University, St Louis, Mo
| | - Umar S Boston
- Division of Cardiothoracic Surgery, Department of Surgery, St Louis Children's Hospital and Washington University, St Louis, Mo
| | - Stuart C Sweet
- Division of Allergy, Immunology, and Pulmonary Medicine, Department of Pediatrics, St Louis Children's Hospital and Washington University, St Louis, Mo
| | - R Mark Grady
- Division of Cardiology, St Louis Children's Hospital and Washington University, St Louis, Mo
| | - Charles B Huddleston
- Division of Pediatric Cardiothoracic Surgery, Department of Surgery, St Louis University, St Louis, Mo
| | - Pirooz Eghtesady
- Division of Cardiothoracic Surgery, Department of Surgery, St Louis Children's Hospital and Washington University, St Louis, Mo.
| |
Collapse
|
43
|
Williamson A, Singh S, Fernekorn U, Schober A. The future of the patient-specific Body-on-a-chip. LAB ON A CHIP 2013; 13:3471-80. [PMID: 23685915 DOI: 10.1039/c3lc50237f] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
As significant advancements in technology focused on Organ-on-a-chip continue, it is feasible to consider the future of Body-on-a-chip technology. With serious work being done to realize functioning artificial livers, kidneys, hearts, and lungs on chips, the next step is not only to interconnect these organs but also to consider the integration of stem cell technology to create interconnected patient-specific organs. Such a patient-specific Body-on-a-chip requires a sophisticated set of tools for micropattering cell cultures in 3D to create interconnected tissue-like organ structures. This review discusses advanced methods of the past two years in on-Chip organs, the complex 3D patterning of cultures and state-of-the-art scaffolding, and discusses some of the most relevant advancements in human-induced pluripotent stem cell (hiPSC) research applied to these organs and scaffolds for the future of a patient-specific Body-on-a-chip. We anticipate that such a technology would have a wide area of application, primarily benefiting drug development, chemical safety testing, and disease modeling.
Collapse
Affiliation(s)
- Adam Williamson
- Department of Nano-Biosystem Technology, Technische Universität Ilmenau, Germany
| | | | | | | |
Collapse
|
44
|
Wu WI, Rochow N, Chan E, Fusch G, Manan A, Nagpal D, Selvaganapathy PR, Fusch C. Lung assist device: development of microfluidic oxygenators for preterm infants with respiratory failure. LAB ON A CHIP 2013; 13:2641-50. [PMID: 23702615 DOI: 10.1039/c3lc41417e] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
This paper reports the development of microfluidic oxygenator (MFO) units designed for a lung assist device (LAD) for newborn infants. This device will be connected to the umbilical vessels like the natural placenta and provide gas exchange. The extracorporeal blood flow is only driven by the pressure difference between the umbilical artery and vein without the use of external pumps. The LAD is designed for use in ambient air (~21% of 760 mmHg). The main focus of this paper is the presentation of the development of the MFO units testing various membrane materials with human blood to enhance gas exchange and in the design of fluidic inlets to lower the pressure drop across the oxygenator. Four different membranes, including thin film PDMS, porous PDMS, and two different pore size porous polycarbonate membranes are compared in this study. Among them, the microfluidic oxygenator with porous PDMS membrane has the highest gas exchange rate of 1.46 μL min(-1) cm(2) for oxygen and 5.27 μL min(-1) cm(2) for carbon dioxide and performs better than a commercial hollow fiber-based oxygenator by 367 and 233%, respectively. A new tapered inlet configuration was designed to reduce the pressure drop across the oxygenator and showed a further 57% improvement over the traditional perpendicular inlet configuration.
Collapse
Affiliation(s)
- Wen-I Wu
- Department of Mechanical Engineering, McMaster University, 1200 Main Street W, Hamilton, L8N 3Z5, Ontario, Canada
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Potkay JA. A simple, closed-form, mathematical model for gas exchange in microchannel artificial lungs. Biomed Microdevices 2013; 15:397-406. [DOI: 10.1007/s10544-013-9736-1] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
46
|
Kang TY, Hong JM, Jung JW, Yoo JJ, Cho DW. Design and assessment of a microfluidic network system for oxygen transport in engineered tissue. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2013; 29:701-709. [PMID: 23234496 DOI: 10.1021/la303552m] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Oxygen and nutrients cannot be delivered to cells residing in the interior of large-volume scaffolds via diffusion alone. Several efforts have been made to meet the metabolic needs of cells in a scaffold by constructing mass transport channels, particularly in the form of bifurcated networks. In contrast to progress in fabrication technologies, however, an approach to designing an optimal network based on experimental evaluation has not been actively reported. The main objective of this study was to establish a procedure for designing an effective microfluidic network system for a cell-seeded scaffold and to develop an experimental model to evaluate the design. We proposed a process to design a microfluidic network by combining an oxygen transport simulation with biomimetic principles governing biological vascular trees. The simulation was performed with the effective diffusion coefficient (D(e,s)), which was experimentally measured in our previous study. Porous scaffolds containing an embedded microfluidic network were fabricated using the lost mold shape-forming process and salt leaching method. The reliability of the procedure was demonstrated by experiments using the scaffolds. This approach established a practical basis for designing an effective microfluidic network in a cell-seeded scaffold.
Collapse
Affiliation(s)
- Tae-Yun Kang
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), Pohang, Gyungbuk 790-784, Korea
| | | | | | | | | |
Collapse
|
47
|
|
48
|
Skolimowski M, Weiss Nielsen M, Abeille F, Skafte-Pedersen P, Sabourin D, Fercher A, Papkovsky D, Molin S, Taboryski R, Sternberg C, Dufva M, Geschke O, Emnéus J. Modular microfluidic system as a model of cystic fibrosis airways. BIOMICROFLUIDICS 2012; 6:34109. [PMID: 23908680 PMCID: PMC3423306 DOI: 10.1063/1.4742911] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2012] [Accepted: 07/24/2012] [Indexed: 05/13/2023]
Abstract
A modular microfluidic airways model system that can simulate the changes in oxygen tension in different compartments of the cystic fibrosis (CF) airways was designed, developed, and tested. The fully reconfigurable system composed of modules with different functionalities: multichannel peristaltic pumps, bubble traps, gas exchange chip, and cell culture chambers. We have successfully applied this system for studying the antibiotic therapy of Pseudomonas aeruginosa, the bacteria mainly responsible for morbidity and mortality in cystic fibrosis, in different oxygen environments. Furthermore, we have mimicked the bacterial reinoculation of the aerobic compartments (lower respiratory tract) from the anaerobic compartments (cystic fibrosis sinuses) following an antibiotic treatment. This effect is hypothesised as the one on the main reasons for recurrent lung infections in cystic fibrosis patients.
Collapse
Affiliation(s)
- M Skolimowski
- Department of Micro- and Nanotechnology, Technical University of Denmark, Ørsted Plads, Building 345B, Kgs. Lyngby DK-2800, Denmark ; Department of Systems Biology, Technical University of Denmark, Matematiktorvet, Building 301, Kgs. Lyngby DK-2800, Denmark
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
49
|
Kumar Mahto S, Tenenbaum-Katan J, Sznitman J. Respiratory physiology on a chip. SCIENTIFICA 2012; 2012:364054. [PMID: 24278686 PMCID: PMC3820443 DOI: 10.6064/2012/364054] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2012] [Accepted: 06/21/2012] [Indexed: 05/12/2023]
Abstract
Our current understanding of respiratory physiology and pathophysiological mechanisms of lung diseases is often limited by challenges in developing in vitro models faithful to the respiratory environment, both in cellular structure and physiological function. The recent establishment and adaptation of microfluidic-based in vitro devices (μFIVDs) of lung airways have enabled a wide range of developments in modern respiratory physiology. In this paper, we address recent efforts over the past decade aimed at advancing in vitro models of lung structure and airways using microfluidic technology and discuss their applications. We specifically focus on μFIVDs covering four major areas of respiratory physiology, namely, artificial lungs (AL), the air-liquid interface (ALI), liquid plugs and cellular injury, and the alveolar-capillary barrier (ACB).
Collapse
Affiliation(s)
- Sanjeev Kumar Mahto
- Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| | - Janna Tenenbaum-Katan
- Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| | - Josué Sznitman
- Department of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
| |
Collapse
|
50
|
Soller EC, Tzeranis DS, Miu K, So PT, Yannas IV. Common features of optimal collagen scaffolds that disrupt wound contraction and enhance regeneration both in peripheral nerves and in skin. Biomaterials 2012; 33:4783-91. [DOI: 10.1016/j.biomaterials.2012.03.068] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Accepted: 03/18/2012] [Indexed: 10/28/2022]
|