1
|
Ralles S, Murphy MP, Farooq H, Grayson W, Hopkinson WJ, Brown NM. Short-term outcomes with routine use of size ≥40 femoral heads in THA: A retrospective cohort study. J Orthop 2025; 59:27-29. [PMID: 39351269 PMCID: PMC11439536 DOI: 10.1016/j.jor.2024.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2024] [Revised: 07/28/2024] [Accepted: 08/02/2024] [Indexed: 10/04/2024] Open
Abstract
Background Using larger femoral heads during total hip arthroplasty (THA) may result in a more stable hip. Greater volumetric wear and frictional torque, however, may result in increased postoperative complications. The purpose of this study was to compare outcomes of patients with femoral head size ≥40 mm compared to those with femoral head size <40 mm. Materials and methods A retrospective chart review of 504 THAs performed by a single surgeon at a single institution from 2009 to 2016 was conducted. Following exclusions, 131 THAs were identified with femoral heads ≥40 mm and 348 THAs were identified with femoral heads <40 mm. In addition to demographic data, all postoperative complications were recorded. Plain radiographs were used to rule out/in periprosthetic osteolysis and/or acetabular loosening. Chi-square tests and Student's t-tests were used to compare categorical and continuous variables, respectively. Results Mean follow-up period for the entire cohort was 5.5 years. Complications with ≥40 mm femoral heads included 1 superficial infection and 1 deep periprosthetic joint infection (PJI). There were no cases of dislocation, osteolysis, acetabular loosening, or trunnionosis. In contrast, complications with <40 mm femoral heads included 9 dislocations and 7 PJIs. Conclusion The routine use of large femoral heads (≥40-mm) during THA appears to be a safe option for patients at short-term clinical follow-up. Notably, 0 patients had a clinical course complicated by dislocation, osteolysis, acetabular loosening, or trunnionosis. Level of evidence Level III Retrospective Cohort Study.
Collapse
Affiliation(s)
- Steven Ralles
- Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
| | - Michael P. Murphy
- Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
| | - Hassan Farooq
- Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
| | - Whisper Grayson
- Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
| | - William J. Hopkinson
- Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
| | - Nicholas M. Brown
- Loyola University Health System, Department of Orthopaedic Surgery and Rehabilitation, Maywood, IL 60153, USA
| |
Collapse
|
2
|
Callary SA, Sharma DK, D’Apollonio TM, Critchley O, Mercer G, Wilson C, Campbell DG. What is the Long-term Wear of a 5-Mrad Highly Crosslinked Polyethylene Liner? A 14-year RSA Study. Clin Orthop Relat Res 2024; 482:1789-1797. [PMID: 38546666 PMCID: PMC11419525 DOI: 10.1097/corr.0000000000003047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 02/27/2024] [Indexed: 09/25/2024]
Abstract
BACKGROUND Lower doses of irradiation (≤ 5 Mrad) during the manufacture of highly crosslinked polyethylene acetabular liners may result in less crosslinking and an increased wear rate. Radiostereometric analysis (RSA) studies have found that wear of more highly irradiated highly crosslinked polyethylene liners (7 to 10 Mrad) decreases at longer-term follow-up compared with earlier reports of the same cohorts. Although wear of 5-Mrad irradiated liners appears to increase at midterm follow-up, it is unclear whether that remains true at longer follow-up. QUESTIONS/PURPOSES We asked: (1) In patients who underwent THA with a 5-Mrad highly crosslinked polyethylene liner, what is the wear rate evaluated with RSA during the first 14 years? (2) Does the wear rate decrease after 6 years in situ? METHODS This is a brief follow-up of prior RSA studies performed at 2 and 6 years. We prospectively reviewed the longer-term wear rate in 13 patients who underwent primary THAs with the same design of a 5-MRad irradiated crosslinked acetabular liner and a 28-mm cobalt-chromium articulation. Of the initial 30 patients who were enrolled, 13 (43%) were available at the 14-year timepoint; nine patients had died, 1 patient had withdrawn, 1 had an intraoperative fracture, 3 patients were too infirm to have radiographs, 2 had no baseline RSA radiographs, and 1 had poor-quality RSA images. Tantalum markers were inserted during surgery, and all patients had RSA radiographic examinations at 1 week, 6 months, and 1, 2, 6, and 14 years postoperatively. RESULTS The mean ± standard deviation proximal, 2D, and 3D wear rates calculated between 1 year and 14 years were 0.019 ± 0.013 mm, 0.022 ± 0.015 mm, and 0.025 ± 0.019 mm per year, respectively. No patient had proximal 2D or 3D wear rates exceeding 0.06 mm per year. An increasing wear rate over time was measured for proximal and 2D wear rates between 6 and 14 years (0.024 and 0.030 mm per year) compared with that between 1 and 6 years (0.008 and 0.010 mm per year; p = 0.03). CONCLUSION The proximal, 2D, and 3D wear of a highly crosslinked polyethylene liner produced using 5-Mrad radiation remains low in the longer-term. With the small numbers available in a long-term RSA study such as this, we confirmed that the wear rate did not decrease at longer-term follow-up, unlike previous RSA studies of more highly irradiated highly crosslinked polyethylene liners. Nevertheless, the wear rate remains very low and below the threshold typically associated with the development of osteolysis (0.1 mm/year of wear). This should provide assurance to orthopaedic surgeons monitoring patients with this 5-Mrad irradiated liner in situ, while providing useful information to manufacturers of future highly crosslinked polyethylene liners. LEVEL OF EVIDENCE Level IV therapeutic study.
Collapse
Affiliation(s)
- Stuart A. Callary
- Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Deepti K. Sharma
- Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Taisha M. D’Apollonio
- Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, South Australia, Australia
| | - Owain Critchley
- Department of Orthopaedics and Trauma Surgery, Flinders University, Adelaide, South Australia, Australia
| | - Graham Mercer
- Department of Orthopaedics, Repatriation General Hospital, Adelaide, South Australia, Australia
| | - Christopher Wilson
- Department of Orthopaedics and Trauma Surgery, Flinders University, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Flinders Medical Centre, Adelaide, South Australia, Australia
| | - David G. Campbell
- Centre for Orthopaedic and Trauma Research, University of Adelaide, Adelaide, South Australia, Australia
- Wakefield Orthopaedic Clinic, Adelaide, South Australia, Australia
| |
Collapse
|
3
|
Migliorini F, Betsch M, Maffulli N, Schäfer L, Hildebrand F, Kubach J, Pasurka M. Rate of revision and wear penetration in different polyethylene liner compositions in total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2024; 14:21162. [PMID: 39256531 PMCID: PMC11387631 DOI: 10.1038/s41598-024-71326-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Accepted: 08/27/2024] [Indexed: 09/12/2024] Open
Abstract
The present Bayesian network meta-analysis compared different types of polyethylene liners in total hip arthroplasty (THA) in terms of wear penetration (mm/year) and rate of revision. The type of liners compared were the crosslinked ultra-high molecular weight polyethylene (CPE/UHMWPE), Vitamin E infused highly cross-linked polyethylene (HXLPE-VEPE), modified cross-linked polyethylene (MXLPE), highly cross-linked polyethylene (HXLPE), Cross-linked polyethylene (XLPE). This study was conducted according to the PRISMA extension statement for reporting systematic reviews incorporating network meta-analyses of healthcare interventions. In June 2024, PubMed, Scopus, Embase, Google Scholar, and Cochrane databases were accessed. A time constraint was set from January 2000. All investigations which compared two or more types of polyethylene liners for THA were accessed. Only studies that clearly stated the nature of the liner were included. Data from 60 studies (37,352 THAs) were collected. 56% of patients were women. The mean age of patients was 60.0 ± 6.6 years, the mean BMI was 27.5 ± 2.0 kg/m2. The mean length of follow-up was 81.6 ± 44.4 months. Comparability was found at baseline between groups. XLPE and HXLPE liners in THA are associated with the lowest wear penetration (mm/year) and the lowest revision rate at approximately 7 years of follow-up.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopedics and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), 39100, Bolzano, Italy.
- Department of Life Sciences, Health, and Health Professions, Link Campus University, 00165, Rome, Italy.
| | - Marcel Betsch
- Department of Orthopaedics and Trauma Surgery, University Hospital Erlangen, 91054, Erlangen, Germany
| | - Nicola Maffulli
- Department of Medicine and Psychology, University of Rome "La Sapienza", Rome, Italy
- School of Pharmacy and Bioengineering, Faculty of Medicine, Keele University, Stoke on Trent, ST4 7QB, UK
- Centre for Sports and Exercise Medicine, Barts and the London School of Medicine and Dentistry, Mile End Hospital, Queen Mary University of London, London, E1 4DG, UK
| | - Luise Schäfer
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Joshua Kubach
- Department of Orthopaedics and Trauma Surgery, University Hospital Erlangen, 91054, Erlangen, Germany
| | - Mario Pasurka
- Department of Orthopaedics and Trauma Surgery, University Hospital Erlangen, 91054, Erlangen, Germany
| |
Collapse
|
4
|
Khan AZ, Maxwell MJ, Parrott RM, Bowler AR, Glass EA, Miller D, Vasconcellos D, Brownhill JR, Austin LS, Cuff DJ, Murthi AM, Smith MJ, Wiater JM, Jawa A. Effect of vitamin E-enhanced highly cross-linked polyethylene on wear rate and particle debris in anatomic total shoulder arthroplasty: a biomechanical comparison to ultrahigh-molecular-weight polyethylene. J Shoulder Elbow Surg 2024; 33:1465-1472. [PMID: 38182025 DOI: 10.1016/j.jse.2023.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 11/03/2023] [Accepted: 11/14/2023] [Indexed: 01/07/2024]
Abstract
BACKGROUND Particle-induced osteolysis resulting from polyethylene wear remains a source of implant failure in anatomic total shoulder designs. Modern polyethylene components are irradiated in an oxygen-free environment to induce cross-linking, but reducing the resulting free radicals with melting or heat annealing can compromise the component's mechanical properties. Vitamin E has been introduced as an adjuvant to thermal treatments. Anatomic shoulder arthroplasty models with a ceramic head component have demonstrated that vitamin E-enhanced polyethylene show improved wear compared with highly cross-linked polyethylene (HXLPE). This study aimed to assess the biomechanical wear properties and particle size characteristics of a novel vitamin E-enhanced highly cross-linked polyethylene (VEXPE) glenoid compared to a conventional ultrahigh-molecular-weight polyethylene (UHMWPE) glenoid against a cobalt chromium molybdenum (CoCrMo) head component. METHODS Biomechanical wear testing was performed to compare the VEXPE glenoid to UHMWPE glenoid with regard to pristine polyethylene wear and abrasive endurance against a polished CoCrMo alloy humeral head in an anatomic shoulder wear-simulation model. Cumulative mass loss (milligrams) was recorded, and wear rate calculated (milligrams per megacycle [Mc]). Under pristine wear conditions, particle analysis was performed, and functional biologic activity (FBA) was calculated to estimate particle debris osteolytic potential. In addition, 95% confidence intervals for all testing conditions were calculated. RESULTS The average pristine wear rate was statistically significantly lower for the VEXPE glenoid compared with the HXLPE glenoid (0.81 ± 0.64 mg/Mc vs. 7.00 ± 0.45 mg/Mc) (P < .05). Under abrasive wear conditions, the VEXPE glenoid had a statistically significant lower average wear rate compared with the UHMWPE glenoid comparator device (18.93 ± 5.80 mg/Mc vs. 40.47 ± 2.63 mg/Mc) (P < .05). The VEXPE glenoid demonstrated a statistically significant improvement in FBA compared with the HXLPE glenoid (0.21 ± 0.21 vs. 1.54 ± 0.49 (P < .05). CONCLUSIONS A new anatomic glenoid component with VEXPE demonstrated significantly improved pristine and abrasive wear properties with lower osteolytic particle debris potential compared with a conventional UHMWPE glenoid component. Vitamin E-enhanced polyethylene shows early promise in shoulder arthroplasty components. Long-term clinical and radiographic investigation needs to be performed to verify if these biomechanical wear properties translate to diminished long-term wear, osteolysis, and loosening.
Collapse
Affiliation(s)
- Adam Z Khan
- Northwest Permanente P.C., Portland, OR, USA
| | | | | | | | | | | | | | | | - Luke S Austin
- Department of Orthopaedic Surgery, The Rothman Institute, Philadelphia, PA, USA
| | - Derek J Cuff
- Suncoast Orthopaedic Surgery and Sports Medicine, Venice, FL, USA
| | | | - Matthew J Smith
- Department of Orthopedic Surgery, University of Missouri, Columbia, MO, USA
| | - J Michael Wiater
- Department of Orthopaedic Surgery, Beaumont Hospital, Royal Oak, MI, USA
| | - Andrew Jawa
- New England Baptist Hospital, Boston, MA, USA.
| |
Collapse
|
5
|
Ngo TB, Josyula A, DeStefano S, Fertil D, Faust M, Lokwani R, Sadtler K. Intersection of Immunity, Metabolism, and Muscle Regeneration in an Autoimmune-Prone MRL Mouse Model. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2306961. [PMID: 38192168 PMCID: PMC10953568 DOI: 10.1002/advs.202306961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 12/07/2023] [Indexed: 01/10/2024]
Abstract
Due to the limited capacity of mammals to regenerate complex tissues, researchers have worked to understand the mechanisms of tissue regeneration in organisms that maintain that capacity. One example is the MRL/MpJ mouse strain with unique regenerative capacity in ear pinnae that is absent from other strains, such as the common C57BL/6 strain. The MRL/MpJ mouse has also been associated with an autoimmune phenotype even in the absence of the mutant Fas gene described in its parent strain MRL/lpr. Due to these findings, the differences between the responses of MRL/MpJ versus C57BL/6 strain are evaluated in volumetric muscle injury and subsequent material implantation. One salient feature of the MRL/MpJ response to injury is robust adipogenesis within the muscle. This is associated with a decrease in M2-like polarization in response to biologically derived extracellular matrix scaffolds. In pro-fibrotic materials, such as polyethylene, there are fewer foreign body giant cells in the MRL/MpJ mice. As there are reports of both positive and negative influences of adipose tissue and adipogenesis on wound healing, this model can provide an important lens to investigate the interplay between stem cells, adipose tissue, and immune responses in trauma and material implantation.
Collapse
Affiliation(s)
- Tran B. Ngo
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| | - Aditya Josyula
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| | - Sabrina DeStefano
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| | - Daphna Fertil
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| | - Mondreakest Faust
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| | - Ravi Lokwani
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| | - Kaitlyn Sadtler
- Section on ImmunoengineeringCenter for Biomedical Engineering and Technology AccelerationNational Institute of Biomedical Imaging and BioengineeringNational Institutes of HealthBethesdaMD20814USA
| |
Collapse
|
6
|
Merfort R, Maffulli N, Hofmann UK, Hildebrand F, Simeone F, Eschweiler J, Migliorini F. Head, acetabular liner composition, and rate of revision and wear in total hip arthroplasty: a Bayesian network meta-analysis. Sci Rep 2023; 13:20327. [PMID: 37989863 PMCID: PMC10663607 DOI: 10.1038/s41598-023-47670-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2023] [Accepted: 11/16/2023] [Indexed: 11/23/2023] Open
Abstract
Total hip arthroplasty (THA) is a common procedure for patients suffering from hip pain e.g. from osteoarthritis, osteonecrosis, or hip fractures. The satisfaction of patients undergoing THA is influenced by the choice of implant type and material, with one key factor being the selection of the appropriate material combination for the bearing surface. In this Bayesian network meta-analysis, we investigated the impact of material combinations for the bearing surface on the longevity of hip implants. The wear penetration rate per year and the total wear penetration in the liner resulting from different material combinations, as well as the survival rate at last follow-up, were examined. We analyzed a total of 663,038 THAs, with 55% of patients being women. Mean patient age was 59.0 ± 8.1 years and mean BMI 27.6 ± 2.6 kg/m2. The combination of an aluminium oxide (Al2O3) head and an Al2O3 liner demonstrated the lowest wear penetration at last follow-up and the lowest rate of wear penetration per year. Additionally, the combination of a crosslinked polyethylene (XLPE) liner and a zircon oxide (ZrO2) head demonstrated the lowest rate of revision at last follow-up. These findings underscore the importance of careful material selection for hip implant bearing surfaces to optimize their longevity and patient satisfaction after THA.
Collapse
Affiliation(s)
- Ricarda Merfort
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Nicola Maffulli
- Department of Medicine and Psicology, University La Sapienza, Rome, Italy
- Faculty of Medicine, School of Pharmacy and Bioengineering, Keele University, Thornburrow Drive, Stoke-on-Trent, England, UK
- Centre for Sports and Exercise Medicine, Barts and the London School of Medicine and Dentistry, Queen Mary University of London, Mile End Hospital, 275 Bancroft Road, London, E1 4DG, England, UK
| | - Ulf Krister Hofmann
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Francesco Simeone
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy
| | - Jörg Eschweiler
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany
| | - Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of the Paracelsus Medical University, 39100, Bolzano, Italy.
| |
Collapse
|
7
|
Ngo TB, Josyula A, DeStefano S, Fertil D, Faust M, Lokwani R, Sadtler K. Ectopic adipogenesis in response to injury and material implantation in an autoimmune mouse model. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.10.05.561105. [PMID: 37986843 PMCID: PMC10659416 DOI: 10.1101/2023.10.05.561105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2023]
Abstract
Due to the limited capacity of mammals to regenerate complex tissues, researchers have worked to understand the mechanisms of tissue regeneration in organisms that maintain that capacity. One example is the MRL/MpJ mouse strain with unique regenerative capacity in ear pinnae that is absent from other strains, such as the common C57BL/6 strain. The MRL/MpJ mouse has also been associated with an autoimmune phenotype even in the absence of the mutant Fas gene described in its parent strain MRL/lpr. Due to these findings, we evaluated the differences between the responses of MRL/MpJ versus C57BL/6 strain in traumatic muscle injury and subsequent material implantation. One salient feature of the MRL/MpJ response to injury was a robust adipogenesis within the muscle. This was associated with a decrease in M2-like polarization in response to biologically derived extracellular matrix scaffolds. In pro-fibrotic materials, such as polyethylene, there were fewer foreign body giant cells in the MRL/MpJ mice. As there are reports of both positive and negative influences of adipose tissue and adipogenesis on wound healing, this model could provide an important lens to investigate the interplay between stem cells, adipose tissue, and immune responses in trauma and materials implantation.
Collapse
Affiliation(s)
- Tran B. Ngo
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| | - Aditya Josyula
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| | - Sabrina DeStefano
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| | - Daphna Fertil
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| | - Mondreakest Faust
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| | - Ravi Lokwani
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| | - Kaitlyn Sadtler
- Section on Immunoengineering, Center for Biomedical Engineering and Technology Acceleration, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda MD 20814
| |
Collapse
|
8
|
Migliorini F, Maffulli N, Pilone M, Bell A, Hildebrand F, Konrads C. Risk factors for liner wear and head migration in total hip arthroplasty: a systematic review. Sci Rep 2023; 13:15612. [PMID: 37730762 PMCID: PMC10511625 DOI: 10.1038/s41598-023-42809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 09/14/2023] [Indexed: 09/22/2023] Open
Abstract
Total hip arthroplasty (THA) is a successful orthopaedic surgical procedure, and its longevity depends on bearing components and implant fixation. Optimizing polyethylene and ceramics has led to improved wear parameters and contributed to improved long-term outcomes. The present systematic review investigated whether time span from implantation, patient characteristics and performance status exert an influence on liner wear and head migration in THA. This study was conducted in conformity to the 2020 PRISMA guidelines. All the clinical investigations which reported quantitative data on the amount of liner wear and head migration in THA were considered. Only studies which reported quantitative data at least on one of the following patient characteristics were suitable: mean age, mean BMI (kg/m2), sex, side, time span between the index THA and the last follow-up (months) were eligible. A multiple linear model regression analysis was employed to verify the association between patient characteristics and the amount of liner wear and/or head migration. The Pearson Product-Moment Correlation Coefficient was used to assess the association between variables. Data from 12,629 patients were considered. The mean length of the follow-up was 90.5 ± 50.9 months. The mean age of patients at surgery was 58.4 ± 9.4 years, and the mean BMI was 27.2 ± 2.5 kg/m2. 57% (7199 of 12,629 patients) were women, and in 44% (5557 of 12,629 patients) THAs were performed on the left. The mean pre-operative Harris hip score was 46.5 ± 6.0 points. There was evidence of a moderate positive association between the amount of liner wear and the time elapsed between the index surgery to the follow-up (P = 0.02). There was evidence of a moderate positive association between the amount of head migration and the time elapsed between the index surgery to the follow-up (P = 0.01). No further statistically significant association was found. The time elapsed between the index surgery to the follow-up was the most important factor which influence the head migration and liner wear in THA. Patients' characteristics and preoperative physical activity did not influence the amount of head migration and liner wear.
Collapse
Affiliation(s)
- Filippo Migliorini
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany.
- Department of Orthopaedic and Trauma Surgery, Academic Hospital of Bolzano, Teaching Hospital of Paracelsus Medical University (PMU), 39100, Bolzano, Italy.
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany.
| | - Nicola Maffulli
- Department of Orthopaedic and Trauma Surgery, Hospital Sant'Andrea, University of Rome La Sapienza, Rome, Italy
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke on Trent, ST4 7QB, England
- Queen Mary University of London, Barts and the London School of Medicine and Dentistry, Centre for Sports and Exercise Medicine, Mile End Hospital, London, E1 4DG, England
| | - Marco Pilone
- Residency Program in Orthopaedics and Traumatology, University of Milan, 20122, Milan, Italy
| | - Andreas Bell
- Department of Orthopaedic and Trauma Surgery, Eifelklinik St.Brigida, Simmerath, Germany
| | - Frank Hildebrand
- Department of Orthopaedic, Trauma, and Reconstructive Surgery, RWTH University Hospital, Pauwelsstraße 30, 52074, Aachen, Germany
| | - Christian Konrads
- Department of Orthopaedics and Traumatology, Helios Hanseatic Hospital Stralsund, 18435, Stralsund, Germany
- Medical Faculty, University of Tübingen, 72076, Tübingen, Germany
| |
Collapse
|
9
|
Kahlenberg CA, Gibbons JAB, Jannat-Khah DP, Goodman SM, Mandl LA, Sculco PK, Goodman SB, Figgie MP, Mehta BY. Use of Total Hip Arthroplasty in Patients Under 21 Years Old: A US Population Analysis. J Arthroplasty 2021; 36:3928-3933.e1. [PMID: 34456091 DOI: 10.1016/j.arth.2021.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 07/26/2021] [Accepted: 08/02/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The purpose of this study is to evaluate trends in the use of total hip arthroplasty (THA) in the United States in patients under 21 years of age. Specifically, we examined the frequency of THA in this patient population over the past 2 decades, the epidemiologic characteristics of patients under 21 who underwent THA, and the characteristics of the hospitals where these procedures were performed. METHODS We retrospectively reviewed the Kids' Inpatient Database, an inpatient US national weighted sample of hospital admissions in patients under 21 from approximately 4200 hospitals in 46 states. We queried the database using Current Procedural Terminology codes for elective and non-elective primary THA for the years 2000-2016. We utilized the International Classification of Diseases, Ninth Revision and International Classification of Diseases, Tenth Revision codes to determine primary diagnoses. RESULTS The weighted total number of THAs performed in patients under 21 in the Kids' Inpatient Database increased from 347 in 2000 to 551 in 2016. The most common diagnoses were osteonecrosis, osteoarthritis, and inflammatory arthritis. The frequency of THA for osteonecrosis increased from 24% in 2000 to 38% in 2016, while the frequency of THA for inflammatory arthritis decreased from 27% in 2000 to 4% in 2016. CONCLUSION The number of THAs in patients under 21 in the United States has increased over the past 2 decades and these procedures are increasingly performed in urban teaching hospitals. The decrease in THA for inflammatory arthritis in this population likely reflects improvements in medical management during the study period.
Collapse
Affiliation(s)
| | - J Alex B Gibbons
- Division of Rheumatology, Department of Medicine, Hospital for Special Surgery, New York, NY
| | - Deanna P Jannat-Khah
- Division of Rheumatology, Department of Medicine, Hospital for Special Surgery, New York, NY; Division of Rheumatology, Department of Medicine, Weill Cornell Medicine, New York, NY
| | - Susan M Goodman
- Division of Rheumatology, Department of Medicine, Hospital for Special Surgery, New York, NY; Division of Rheumatology, Department of Medicine, Weill Cornell Medicine, New York, NY
| | - Lisa A Mandl
- Division of Rheumatology, Department of Medicine, Hospital for Special Surgery, New York, NY; Division of Rheumatology, Department of Medicine, Weill Cornell Medicine, New York, NY
| | - Peter K Sculco
- Department of Orthopedics, Hospital for Special Surgery, New York, NY
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford University, Stanford, CA
| | - Mark P Figgie
- Department of Orthopedics, Hospital for Special Surgery, New York, NY
| | - Bella Y Mehta
- Division of Rheumatology, Department of Medicine, Hospital for Special Surgery, New York, NY; Division of Rheumatology, Department of Medicine, Weill Cornell Medicine, New York, NY
| |
Collapse
|
10
|
Bergvinsson H, Zampelis V, Sundberg M, Flivik G. Highly cross-linked polyethylene still outperforms conventional polyethylene in THA: 10-year RSA results. Acta Orthop 2021; 92:568-574. [PMID: 34139928 PMCID: PMC8519538 DOI: 10.1080/17453674.2021.1932140] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - Cup wear in total hip arthroplasty (THA) can be affected by different manufacturing processes of the polyethylene (PE). We report the long-term wear pattern differences, as well as early creep behavior, between conventional PE and highly cross-linked PE (HXLPE) liners, as measured with radiostereometry (RSA) up to 10 years. We also compare migration and clinical outcome of 2 similar uncemented cups with different backside surface roughness.Patients and methods - We included 45 patients with primary osteoarthritis. 23 received a conventional liner and 22 an HXLPE liner in a similar uncemented cup, but with a slightly rougher surface. The patients were followed up with RSA and hip-specific outcome questionnaire (HOOS) at 3 months, 1, 2, 5, and 10 years.Results - During the first 3 months both liners showed expected deformation with mean proximal head penetration of 0.39 mm (conventional PE) and 0.21 mm (HXLPE). Between 3 months and 10 years there was a difference in annual wear with 0.12 mm/year for the conventional liner and 0.02 mm/year for the HXLPE liner. The cup with rougher surface had less initial migration but both types had stabilized after 3 months. The HOOS scores improved after surgery and remained high for both groups throughout the study period.Interpretation - Up to 10 years the HXLPE has consistent lower annual wear, possibly contributing to longer survival of the THA, compared with conventional PE. All patients reported good results regardless of liner type.
Collapse
Affiliation(s)
- Halldor Bergvinsson
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden,Correspondence:
| | - Vasilis Zampelis
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Martin Sundberg
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| | - Gunnar Flivik
- Department of Orthopedics, Skåne University Hospital, Clinical Sciences, Lund University, Lund, Sweden
| |
Collapse
|
11
|
Upfill-Brown A, Hsiue PP, Sekimura T, Patel JN, Adamson M, Stavrakis AI. Instability Is the Most Common Indication for Revision Hip Arthroplasty in the United States: National Trends From 2012 to 2018. Arthroplast Today 2021; 11:88-101. [PMID: 34504922 PMCID: PMC8413665 DOI: 10.1016/j.artd.2021.08.001] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 07/23/2021] [Accepted: 08/02/2021] [Indexed: 11/26/2022] Open
Abstract
Background As primary total hip arthroplasty volume continues to increase, so will the number of revision total hip arthroplasty (rTHA) procedures. These complex cases represent a significant clinical and financial burden to the health-care system. Methods This was a retrospective review using the National Inpatient Sample. International Classification of Diseases, 9th and 10th revision codes were used to identify patients who underwent rTHA and create cohorts based on rTHA indications from 2012 to 2018. National and regional trends for length of stay (LOS), cost, and discharge location were evaluated. Results A total of 292,250 rTHA procedures were identified. The annual number of rTHA procedures increased by 28.1% from 2012 to 2018 (37,325 to 47,810). The top 3 indications for rTHA were instability (20.4%), aseptic loosening (17.8%), and infection (11.1%). Over the study period, the proportion of patients discharged to skilled nursing facility decreased from 44.2% to 38% (P < .001). Hospital LOS decreased on average from 4.8 to 4.4 days (P < .001). Infections had the highest average LOS (7.3 days) followed by periprosthetic fractures (6.5 days). Hospital costs decreased over the study period, from $25,794 to $24,555 (P < .001). The proportion of rTHA cases performed at urban academic centers increased (58.0% to 75.3%, P < .001) while the proportion performed at urban nonacademic centers decreased (35.5% to 19.4%, P < .001). Conclusion Instability was the most common indication for rTHA between 2012 and 2018. The proportion of rTHA performed in urban academic centers has increased substantially, away from urban nonacademic centers. While cost and LOS have decreased, significant geographic variability exists.
Collapse
Affiliation(s)
| | | | | | | | | | - Alexandra I. Stavrakis
- Corresponding author. 1250 16 Street, Suite 2100, Santa Monica, CA 90404, USA. Tel.: +1-424-259-9804.
| |
Collapse
|
12
|
Mahmood FF, Beck M, de Gast A, Rehbein P, French GJ, Becker R, Dominkus M, Helmy N, Hollmann L, Baines J. Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study. J Arthroplasty 2021; 36:1700-1706. [PMID: 33516632 DOI: 10.1016/j.arth.2020.12.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Addition of vitamin E to polyethylene is theorized to reduce the potential for oxidative wear in acetabular components. This paper presents a multicenter prospective cohort study that reports on outcomes from use of a Vitamin E-infused highly cross-linked polyethylene acetabular cup. METHODS Patients were recruited across nine medical institutions. Clinical outcome measures recorded were the Harris Hip Score, visual analogue score for pain and satisfaction. Evidence of implant loosening or osteolysis was collected radiologically. Cup survival and reasons for revision in relevant cases were also recorded. Data collection was undertaken preoperatively, at 6-12 weeks, 6 months, 1 year, 2 years, and 5 years. A total of 675 patients were recruited, with 450 cases available at final review. Data regarding cup survival was available to 8 years and 9 months postoperatively. RESULTS Improvements in both the Harris Hip Score and visual analogue score for pain and satisfaction were recorded at all time points, with these being maintained through the length of follow-up. In total, 89% of cups were implanted within the Lewinnek safe zone. A lucent line was identified in one case, with no evidence of acetabular osteolysis observed throughout the follow-up period. Cup survival was 98.9% at 8 years and 9 months. No revisions for aseptic loosening were observed. CONCLUSIONS The use of a vitamin E-infused polyethylene acetabular cup demonstrates reassuring patient-reported outcomes, radiological measures, and cup survival at medium to long-term follow-up.
Collapse
Affiliation(s)
- Fahd F Mahmood
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - Martin Beck
- Luzerner Kantonsspital, Luzern, Switzerland; Orthopaedic Clinic Lucerne, Hirslanden Clinic St. Anna, Lucerne
| | - Arthur de Gast
- Diakonessenhuis Utrecht, Utrecht, the Netherlands; Clinical Orthopedic Research Center Midden-Nederland, Diakonessenhuis Zeist, Zeist, the Netherlands
| | - Philipp Rehbein
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | | | - Roland Becker
- Dept. of Orthopedics and Traumatology, Brandenburg Medical School, Brandenburg, Germany
| | - Martin Dominkus
- Orthopaedic Department, Orthopädisches Spital Speising, Wien, Austria; Sigmund Freud University, Campus Prater Freudplatz 1, Wien, Austria
| | - Naeder Helmy
- Department of Orthopaedics, Nurgerspital Solothurn, Solothurn, Switzerland
| | - Lutz Hollmann
- Streekziekenhuis Koningin Beatrix, Winterswijk, the Netherlands
| | - Joe Baines
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| |
Collapse
|
13
|
Abstract
INTRODUCTION Recent advances in polyethylene and ceramic technologies has allowed us to use larger sized heads without compromising the wear properties of a total hip arthroplasty (THA). 1 benefit of this change has been proposed to be a lower incidence of dislocation. METHODS We retrospectively evaluated the dislocation rate in 913 THAs performed using the same standardised surgical technique employed by a single team of surgeons at our institution between 1995 and 2015. Patients were assigned to 2 groups: small (⩽28 mm), large diameter heads (⩾36 mm and larger). The cup position was measured and plotted to determine its status according to the Lewinnek's safe zone (15° ± 10° for anteversion, 40° ± 10° for inclination). RESULTS 16 of the 472 small heads dislocated (3.4%) while 5 of the 441 in large head group (1.1%) (p = 0.04). In all of the large head patients that dislocated the cup position was in the safe range of Lewinnek. However, in the large head group only 64.5% of the cups were in the safe zone. CONCLUSIONS By changing the head size to 36 mm, we were able to decrease the dislocation rate significantly. Errors of cup positioning according to Lewinnek became oblivious when using large heads. In our opinion, using large heads in THA makes a difference in terms of dislocation.
Collapse
Affiliation(s)
- Erkan Sabri Ertaş
- Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Turkey
| | - A Mazhar Tokgözoğlu
- Department of Orthopaedics and Traumatology, Hacettepe University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
14
|
Prock-Gibbs H, Pumilia CA, Meckmongkol T, Lovejoy J, Mumith A, Coathup M. Incidence of Osteolysis and Aseptic Loosening Following Metal-on-Highly Cross-Linked Polyethylene Hip Arthroplasty: A Systematic Review of Studies with Up to 15-Year Follow-up. J Bone Joint Surg Am 2021; 103:728-740. [PMID: 33411465 DOI: 10.2106/jbjs.20.01086] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND This study compared the incidence of osteolysis, aseptic loosening, and revision following use of highly cross-linked polyethylene (HXLPE) or conventional polyethylene (CPE) at medium to long-term (>5 to 15 years) follow-up in primary total hip arthroplasty (THA). Incidences were quantified and compared with regard to age and method of implant fixation. METHODS Using the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) guidelines, 12 randomized controlled trials and 18 cohort studies were investigated for evidence-based outcomes following HXPLE and CPE use in 2,539 hips over a 5 to 15-year follow-up. RESULTS Lower rates of osteolysis, aseptic loosening, and implant revision were reported following use of HXLPE liners. Osteolysis was reduced from 25.4% with CPE to 4.05% with HXLPE in young patients, and from 29.7% to 6.6% in the older patient cohort. Similarities in osteolysis rates were observed when cemented (24.9% for CPE and 6.5% for HXLPE) and uncemented components (32.8% for CPE and 7.1% for HXLPE) were compared. No clear advantage in the type of HXLPE used was observed. CONCLUSIONS Over a follow-up period of up to 15 years, when compared with CPE, use of HXLPE liners reduced the incidence of osteolysis, aseptic loosening, and implant revision, regardless of the fixation method and including in younger and potentially more active patients. LEVEL OF EVIDENCE Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
| | | | - Teerin Meckmongkol
- College of Medicine, University of Central Florida, Orlando, Florida.,Departments of General Surgery (T.M.) and Orthopaedics, Sports Medicine and Physical Medicine and Rehabilitation (J.L.), Nemours Children's Hospital, Orlando, Florida
| | - John Lovejoy
- College of Medicine, University of Central Florida, Orlando, Florida.,Departments of General Surgery (T.M.) and Orthopaedics, Sports Medicine and Physical Medicine and Rehabilitation (J.L.), Nemours Children's Hospital, Orlando, Florida
| | - Aadil Mumith
- College of Medicine, University of Central Florida, Orlando, Florida.,Department of Orthopaedics, Basingstoke and North Hampshire Hospital, Basingstoke, United Kingdom
| | - Melanie Coathup
- College of Medicine, University of Central Florida, Orlando, Florida
| |
Collapse
|
15
|
Smith CS, Mollon B, Vannabouathong C, Fu JM, Sales B, Bhandari M, Whelan DB. An Assessment of Randomized Controlled Trial Quality in The Journal of Bone & Joint Surgery: Update from 2001 to 2013. J Bone Joint Surg Am 2020; 102:e116. [PMID: 33086352 DOI: 10.2106/jbjs.18.00653] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The quality of reporting of randomized controlled trials (RCTs) published in The Journal of Bone & Joint Surgery (JBJS) from 1988 to 2000 was previously analyzed. The purpose of this current study was to analyze the quality of reporting of RCTs published in JBJS from 2001 to 2013 to identify trends over time and potential areas of improvement for future clinical trials. METHODS A manual search of the JBJS database identified RCTs published between January 2001 and December 2013. Quality assessments, using the Detsky quality-of-reporting index (Detsky score), a modified Cochrane risk-of-bias tool, and abstraction of relevant data identifying predictors of quality, were conducted. RESULTS A total of 5,780 publications were identified in JBJS from 2001 to 2013, with 285 RCTs (4.9%), representing an increase from the prior 13-year period. The overall mean transformed Detsky score (and standard error) increased significantly (p < 0.001) from 68.1% ± 1.67% to 76.24% ± 0.72%. The percentage of multicenter RCTs decreased from 67% to 31%. The percentage of positive trials also decreased from 80% to 50.5%, as did the mean sample size (212 to 166). Regression analysis indicated that trials with an epidemiologist as the first author and nonsurgical trials were significantly associated (p = 0.001) with a higher overall trial quality score. The categories of the lowest mean methodology scores were randomization and concealment, eligibility criteria, and reasons for patient exclusion, as identified with the Detsky score, and patient and assessor blinding, as identified with the risk-of-bias assessment. CONCLUSIONS The quantity and quality of published RCTs in JBJS have increased in the 2001 to 2013 time period compared with the previous time period. Although these improvements are encouraging, trends to smaller, single-center trials were also observed. To efficiently determine the efficacy of orthopaedic treatments and limit bias, high-quality randomized trials of appropriate sample size and rigorous design are needed.
Collapse
Affiliation(s)
| | - Brent Mollon
- Soldiers' Memorial Hospital, Orillia, Ontario, Canada
| | | | - Joyce M Fu
- Department of Orthopaedics, University of Toronto, Toronto, Ontario, Canada
| | | | - Mohit Bhandari
- Department of Clinical Epidemiology & Biostatistics, McMaster University, Hamilton, Ontario, Canada
| | - Daniel B Whelan
- University of Toronto Orthopaedic Sports Medicine, St. Michael's and Women's College Hospitals, Toronto, Ontario, Canada
| |
Collapse
|
16
|
Sobajima A, Okihara T, Moriyama S, Nishimura N, Osawa T, Miyamae K, Haniu H, Aoki K, Tanaka M, Usui Y, Sako KI, Kato H, Saito N. Multiwall Carbon Nanotube Composites as Artificial Joint Materials. ACS Biomater Sci Eng 2020; 6:7032-7040. [PMID: 33320600 DOI: 10.1021/acsbiomaterials.0c00916] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Because ultrahigh-molecular-weight polyethylene (UHMWPE) is susceptible to frictional wear when used in sliding members of artificial joints, it is common practice to use cross-linked UHMWPE instead. However, cross-linked UHMWPE has low impact resistance; implant breakage has been reported in some cases. Hence, sliding members of artificial joints pose a major trade-off between wear resistance and impact resistance, which has not been resolved by any UHMWPE. On the other hand, multiwall carbon nanotubes (MWCNTs) are used in industrial products for reinforcement of polymeric materials but not used as biomaterials because of their unclear safety. In the present study, we attempted to solve this trade-off issue by complexing UHMWPE with MWCNTs. In addition, we assessed the safety of these composites for use in sliding members of artificial joints. The results showed the equivalence of MWCNT/UHMWPE composites to cross-linked UHMWPE in terms of wear resistance and to non-cross-linked UHMWPE in terms of impact resistance. In addition, all MWCNT/UHMWPE composites examined complied with the requirements of biosafety testing in accordance with the ISO10993-series specifications for implantable medical devices. Furthermore, because MWCNTs can occur alone in wear dust, MWCNTs in an amount of about 1.5 times that contained in the dust produced from 50 years of wear (in the worst case) were injected into rat knees, which were monitored for 26 weeks. Although mild inflammatory reactions occurred in the joints, the reactions soon became quiescent. In addition, the MWCNTs did not migrate to other organs. Furthermore, MWCNTs did not exhibit carcinogenicity when injected into the knees of mice genetically modified to spontaneously develop cancer. The MWCNT/UHMWPE composite is a new biomaterial expected to be safe for clinical applications in both total hip arthroplasty and total knee arthroplasty as the first sliding member of artificial joints to have both high wear resistance and high impact resistance.
Collapse
Affiliation(s)
- Atsushi Sobajima
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan
| | - Takumi Okihara
- Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama, Okayama 700-0082, Japan
| | - Shigeaki Moriyama
- Faculty of Engineering, Fukuoka University, 8-19-1 Nanakuma, Jonan-ku, Fukuoka, Fukuoka 814-0133, Japan
| | - Naoyuki Nishimura
- Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research, Shinshu University, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan
| | - Takako Osawa
- Faculty of Biology-Oriented Science and Technology, Kindai University, 930 Nishimitani, Kinokawa, Wakayama 649-6433, Japan
| | - Kazutaka Miyamae
- Graduate School of Natural Science and Technology, Okayama University, 3-1-1 Tsushima-naka, Kita-ku, Okayama, Okayama 700-0082, Japan
| | - Hisao Haniu
- Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research, Shinshu University, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan
| | - Kaoru Aoki
- Department of Applied Physical Therapy, Shinshu University School of Health Sciences, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan
| | - Manabu Tanaka
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-862, Japan
| | - Yuki Usui
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan
| | - Ken-Ichi Sako
- Clinical Pharmacology Educational Center, Nihon Pharmaceutical University, 10281 Komuro, Ina, Kita-Adachi, Saitama 362-0806, Japan
| | - Hiroyuki Kato
- Department of Orthopaedic Surgery, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano 390-862, Japan
| | - Naoto Saito
- Institute for Biomedical Sciences, Interdisciplinary Cluster for Cutting Edge Research, Shinshu University, 3-1-1 Asahi, Matsumoto, Nagano 390-8621, Japan
| |
Collapse
|
17
|
Raman spectroscopy reveals creep and wear rate of e-beam-sterilized conventional UHMWPE tibial inserts. J Mech Behav Biomed Mater 2020; 110:103902. [DOI: 10.1016/j.jmbbm.2020.103902] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2020] [Revised: 05/01/2020] [Accepted: 05/30/2020] [Indexed: 11/19/2022]
|
18
|
Schachtner JT, MacDonald DW, Klein GR, Malkani AL, Kraay M, Rimnac CM, Mont MA, Lee GC, Kurtz SM. Are the Wear and Osteolysis Outcomes Different between Annealed and Remelted First-Generation Highly Crosslinked Polyethylene after Long-Term Implantation? ACTA ACUST UNITED AC 2020. [DOI: 10.1055/s-0040-1716576] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
AbstractFirst-generation highly crosslinked polyethylene (HXLPE) was developed to reduce polyethylene wear debris and subsequent osteolysis. Two thermal stabilization strategies were developed, annealing and remelting, to remove free radicals remaining in the polymer. Both types of HXLPEs have demonstrated better wear resistance to conventional polyethylene in hip arthroplasty. However, few studies have directly compared the mid- to long-term clinical outcomes of first-generation HXLPEs. We sought to address the following research questions: (1) is there a difference between the revision reasons for HXLPE formulations (annealed and remelted), (2) is there a difference in oxidation between annealed and remelted HXLPEs, (3) is there a difference in the linear penetration rate of annealed and remelted HXLPEs, and (4) does the formulation of first-generation HXLPEs affect the prevalence of osteolysis? A total of 129 first-generation HXLPE acetabular liners were collected in a multicenter retrieval program. These components were implanted for 5 or more years and were fabricated from annealed or remelted HXLPE. Reasons for revision, body mass index, age, sex, and activity levels were collected from medical records. Oxidation was measured at four regions of interest: bearing surface, backside surface, locking mechanism, and rim. Liner penetration was directly measured from retrievals using a micrometer. Osteolysis was reported in the operative notes by the revising surgeon and a thorough review of the operative notes and radiographs. Revision reasons included infection, instability, pain, and loosening. The annealed liners had higher oxidation indices than remelted liners. There was no difference in linear penetration rates between cohorts. There was no difference in osteolysis prevalence between cohorts. We found remelted HXLPE to be more oxidatively stable than annealed HXLPE but did not find a significant difference in the linear penetration rates or the prevalence of osteolysis. Our findings demonstrate sustained long-term wear resistance of both cohorts of HXLPE. We did not find evidence to support a long-term clinical difference between the formulations of HXLPE.
Collapse
Affiliation(s)
| | - Daniel W. MacDonald
- Implant Research Core, Drexel University School of Biomedical Engineering Science and Health Systems, Philadelphia, Pennsylvania
| | - Gregg R. Klein
- Department of Orthopaedic Surgery, Rothman Institute, Montvale, New Jersey
| | - Arthur L. Malkani
- Department of Orthopedics, University of Louisville, Louisville, Kentucky
| | - Matthew Kraay
- Department of Orthopaedics, University Hospitals Cleveland Medical Center, Cleveland, Ohio
| | - Clare M. Rimnac
- Center for the Evaluation of Implant Performance, Case Western Reserve University Case School of Engineering, Cleveland, Ohio
| | - Michael A. Mont
- Department of Orthopaedic Surgery, Lenox Hill Hospital at Northwell Health, New York City, New York
| | - Gwo-Chin Lee
- Department of Orthopaedic Surgery, Penn Presbyterian Medical Center, Philadelphia, Pennsylvania
| | - Steven Michael Kurtz
- Department of Biomedical Engineering, Exponent Inc., Philadelphia, Pennsylvania
- Implant Research Core, Drexel University School of Biomedical Engineering Science and Health Systems, Philadelphia, Pennsylvania
| |
Collapse
|
19
|
Parashin S, Gascoyne T, Zarrabian M. A phantom and cadaveric study of radiostereometric analysis in posterior cervical and lumbar spinal fusion. Spine J 2020; 20:1333-1343. [PMID: 32272254 DOI: 10.1016/j.spinee.2020.03.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 03/26/2020] [Accepted: 03/27/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT Detecting pseudarthrosis following spinal fusion is important for accurate diagnosis and treatment. Current diagnostic measures hold certain drawbacks. Radiostereometric analysis (RSA) is a radiographic technique with the capability to measure intervertebral segment changes and may be a novel way of assessing fusion. PURPOSE The purpose of this work was to measure the accuracy and precision of RSA in instrumented posterior cervical and lumbar spinal fusion for measuring intervertebral movement. Further, to gain surgical practice with RSA in spine and determine optimal bead placements. STUDY DESIGN Artificial bone and cadaveric spine models were used to simulate a 3-level cervical (C3-C6) and a 2-level (L4-S1) lumbosacral posterior spinal fusion to analyze bead placements and to measure RSA accuracy and precision. METHODS Preliminary RSA bead placements were planned and measured in the artificial model. Secondary bead placements were adjusted slightly in the cadaveric model to consider additional fusion scenarios. Bead spread, detectability, and stability were measured to determine optimal placements. Translational and rotational precision of both models were measured. Accuracy was measured in the artificial spine model. Model-based RSA software was used for analysis. RESULTS Optimal bead placements were found to be throughout the lateral mass of C3-C6 and in the spinous process, transverse process, and within the screw canal of L4-S1. Detectability was high among all segments. Spread was greater in L4-S1 than C3-C6 due to bead collinearity along the transverse axis of the cervical vertebrae. Translational and rotational RSA accuracy in cervical and lumbosacral regions ranged between 0.005 to 0.014 mm and 0.058 to 0.208°. Translational and rotational precision measured in the phantom models ranged 0.017 to 0.131 mm and 0.058 to 0.394° in C3-C6, and 0.086 to 0.191 mm and 0.200 to 0.369° in L4-S1. Translational and rotational precision measured in the cadaveric models ranged 0.054 to 0.548 mm and 0.148 to 1.386° in C3-C6, and 0.068 to 0.164 mm and 0.100 to 0.270° in L4-S1. CONCLUSIONS RSA was found to be a feasible radiographic technique in C3-C6 and L4-S1 spinal fusion when measured in artificial and cadaveric models. Optimal bead placements were determined. Bead spread was shown to be better throughout the lumbar region than the cervical region due to anatomical size variations. RSA accuracy and precision were within acceptable RSA criteria. CLINICAL SIGNIFICANCE The results from this work contribute to the accuracy, precision, and bead placements for studying RSA in cervical and lumbar spinal fusions. This work may further support the development of clinical studies to assess spinal fusion by evaluating postoperative intervertebral movement using RSA.
Collapse
Affiliation(s)
- Sara Parashin
- The Orthopaedic Innovation Centre, Suite 320-1155 Concordia Avenue, Winnipeg, Manitoba, Canada, R2K 2M9.
| | - Trevor Gascoyne
- The Orthopaedic Innovation Centre, Suite 320-1155 Concordia Avenue, Winnipeg, Manitoba, Canada, R2K 2M9
| | - Mohammad Zarrabian
- Department of Surgery, Faculty of Medicine, AE 101-820 Sherbrook Street, University of Manitoba, Winnipeg, Manitoba, Canada, R3A 1R9
| |
Collapse
|
20
|
Van de Kleut ML, Athwal GS, Faber KJ, Teeter MG. In vivo volumetric and linear wear measurement of reverse shoulder arthroplasty at minimum 5-year follow-up. J Shoulder Elbow Surg 2020; 29:1695-1702. [PMID: 32192882 DOI: 10.1016/j.jse.2019.11.031] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 11/11/2019] [Accepted: 11/23/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty is quickly becoming the most frequently performed glenohumeral joint replacement. The purpose of this study was to evaluate the volumetric and linear wear rates of ultrahigh-molecular-weight polyethylene humeral liners in vivo at a minimum 5-year follow-up. METHODS Radiostereometric analysis was used to image 15 patients at terminal range of motion in forward flexion, abduction, external rotation, and internal rotation and with the arm at the side. The relative position and orientation of the glenosphere and polyethylene were identified for each arm position. The apparent intersection of the glenosphere into the polyethylene was recorded as wear. Mean volumetric and linear wear rates were recorded, and Pearson correlation coefficients were applied to the 36-mm liners to assess the relationship between the wear rate and term of service. RESULTS The mean reverse shoulder arthroplasty term of service at the time of imaging was 8 ± 1 years (range, 6-11 years). The mean volumetric and linear wear rates for the 36-mm liners (n = 13) were 42 ± 22 mm3/yr (r = 0.688, P = .009) and 0.11 ± 0.03 mm/yr (r = 0.767, P = .002), respectively. The mean volumetric and linear wear rates for the 42-mm liners (n = 2) were 114 ± 44 mm3/yr and 0.17 ± 0.01 mm/yr, respectively. No single arm position was able to capture all recorded wear individually. CONCLUSION This study showed volumetric and linear wear rates of approximately 40 mm3/yr and 0.1 mm/yr, respectively, for the 36-mm polyethylene liners. The 42-mm liners showed higher wear rates, although a greater number of subjects is required for conclusive results. In vivo wear of reverse total shoulder arthroplasty is multidirectional and perceptible.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; School of Biomedical Engineering, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada
| | - George S Athwal
- Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Kenneth J Faber
- Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada
| | - Matthew G Teeter
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Lawson Health Research Institute, London, ON, Canada; Division of Orthopaedic Surgery, Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada; Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, ON, Canada.
| |
Collapse
|
21
|
Overview of Randomized Controlled Trials in Primary Total Hip Arthroplasty (34,020 Patients): What Have We Learnt? JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS 2020; 4:e20.00120. [PMID: 32852916 PMCID: PMC7417146 DOI: 10.5435/jaaosglobal-d-20-00120] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Aim: To provide an overview of randomized controlled trials (RCTs) in primary total hip arthroplasty summarizing the available high-quality evidence. Materials and Methods: Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA), we searched the Cochrane Central Register of Controlled Trials (2020, Issue 1), Ovid MEDLINE, and Embase. We excluded nonrandomized trials, trials on neck of femur fractures or revision surgery, systematic reviews, and meta-analyses. Trials that met our inclusion criteria were assessed using a binary outcome measure of whether they reported statistically significant findings. These were then classified according to the intervention groups (surgical approach, fixation, and component design use, among others). Results: Three hundred twelve RCTs met the inclusion criteria and were included. The total number of patients in those 312 RCTs was 34,020. Sixty-one RCTs (19.5%) reported significant differences between the intervention and the control groups. The trials were grouped into surgical approach 72, fixation 7, cement 16, femoral stem 46, head sizes 5, cup design 18, polyethylene 25, bearing surfaces 30, metal-on-metal 30, resurfacing 20, navigation 15, robotics 3, surgical technique 12, and closure/drains/postoperative care 13 RCTs. Discussion: The evidence reviewed indicates that for the vast majority of patients, a standard conventional total hip arthroplasty with a surgical approach familiar to the surgeon using standard well-established components and highly cross-linked polyethylene leads to satisfactory clinical outcomes. This evidence also offers arthroplasty surgeons the flexibility to use the standard and cost-effective techniques and achieve comparable outcomes.
Collapse
|
22
|
Computed Tomographic Osteolytic Analysis of a First-Generation Remelted Highly Cross-Linked Polyethylene in Total Hip Arthroplasty-At a Minimum of 15-Year Follow-Up. J Arthroplasty 2020; 35:1417-1423. [PMID: 31948813 DOI: 10.1016/j.arth.2019.12.012] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 11/25/2019] [Accepted: 12/09/2019] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Low polyethylene wear rate and low incidence of osteolysis have been reported after total hip arthroplasty (THA) using first-generation remelted highly cross-linked polyethylene (HXLPE). However, osteolysis has not been evaluated in long-term studies of these patients (15 years or more). The present study assessed computed tomography (CT) images to determine the incidence of osteolysis associated with HXLPE in THA during at least 15 years of follow-up. METHODS We evaluated 105 primary THAs in 84 patients (77 women and 7 men). Mean follow-up was 15.9 years (range, 15-18 years). All THAs used a Longevity HXLPE liner and a 26-mm zirconia femoral head. Areas of osteolysis were identified from CT images using 3D and multiplanar reconstruction views. RESULTS CT 3D multiplanar reconstruction images at 15-year follow-up showed no obvious osteolysis in the acetabulum or femur of any patient. No patients developed cup loosening or liner breakage. CONCLUSION Our study indicates that first-generation remelted HXLPE liners do not increase the risk of osteolysis during 15-year follow-up and suggests that the wear particles from first-generation remelted HXLPE are less biologically active than those generated by conventional polyethylene devices.
Collapse
|
23
|
Klasan A, Neri T, Sen A, El-Zayat BF, Efe T, Lahner M, Heyse TJ. Titanium acetabular cementless cups combined with highly crosslinked polyethylene liner have very low rates of aseptic loosening. Technol Health Care 2019; 28:415-423. [PMID: 31796715 DOI: 10.3233/thc-191896] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND There is a clear tendency towards cementless acetabular components in primary total hip arthroplasty. OBJECTIVE The aim of this study was to assess the long-term clinical and radiological outcome of titanium cementless acetabular cups when combined with a highly crosslinked polyethylene liner. METHODS This study is a retrospective follow-up of 67 cups in 64 patients. Clinical outcomes were assessed using the Harris Hip Score. Radiolucent lines, osteolysis and loosening were assessed radiologically. Implant survival was determined using the Kaplan-Meier analysis. RESULTS The average Harris Hip Score at follow-up was 80.3 ± 14.5. Signs of osteolysis were observed in 7.1% of the radiographs. No aseptic loosening of the cup was reported. Survival of the cup with aseptic loosening as an endpoint was 100%. A comparison with 19 other studies using the same material combination demonstrated very similar results. All manufacturers with available studies have at least one report of 100% survivorship at 10-year follow-up for their titanium cup and highly crosslinked polyethylene acetabular component combination with aseptic loosening as an endpoint. CONCLUSIONS The data suggests that the rate of aseptic loosening of a titanium cup combined with a highly-crosslinked polyethylene liner at 10-year follow-up could be as low as 0%.
Collapse
Affiliation(s)
- Antonio Klasan
- University Hospital Marburg, Center for Orthopedics and Traumatology, Baldingerstrasse, 35043 Marburg, Germany
| | - Thomas Neri
- Department of Orthopaedic Surgery, University Hospital of Saint Etienne, France
| | - Ahmet Sen
- Clinic Jung-Stilling, Department for Trauma, Siegen, Germany
| | | | | | | | | |
Collapse
|
24
|
Könneker S, Krockenberger K, Pieh C, von Falck C, Brandewiede B, Vogt PM, Kirschner MH, Ziegler A. Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial. BMC Musculoskelet Disord 2019; 20:357. [PMID: 31387574 PMCID: PMC6685162 DOI: 10.1186/s12891-019-2723-9] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 06/26/2019] [Indexed: 11/10/2022] Open
Abstract
Background Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or are removed after healing. An alternative are biodegradable magnesium-based implants. Properties of magnesium alloys include high stability, osteoconductivity, potential reduction of infections and few artifacts in magnetic resonance imaging (MRI). The aim of this trial is to demonstrate non-inferiority of magnesium-based compression screws compared with titanium Herbert screws for scaphoid fractures. Methods The trial is designed as a multicenter, blinded observer, randomized controlled parallel two-group post market trial. Approximately 190 patients will be randomized (1:1) with stratification by center either to titanium or magnesium-based compression screws. Follow-up is 1 year per patient. Surgical procedures and aftercare will be performed according to the German treatment guideline for scaphoid fractures. The first primary endpoint is the patient-rated wrist evaluation (PRWE) score after 6 months. The second primary endpoint is a composite safety endpoint including bone union until 6 months, no adverse device effect (ADE) during surgery or wound healing and no serious ADE or reoperation within 1 year. The third primary endpoint is the difference in change MRI artifacts over time. Non-inferiority will be investigated for primary endpoints 1 (t-test confidence interval) and 2 (Wilson’s score interval) using both the full analysis set (FAS) and the per protocol population at the one-sided 2.5% test-level. Superiority of magnesium over titanium screws will be established using the FAS at the two-sided 5% test-level (Welch test) only if non-inferiority has been established for both primary endpoints. Secondary endpoints include quality of life. Discussion This study will inform care providers whether biodegradable magnesium-based implants are non-inferior to standard titanium Herbert screws for the treatment of scaphoid fractures in terms of wrist function and safety. Furthermore, superiority of magnesium-based implants may be demonstrated using MRI, which is used as surrogate endpoint for screw degradation. Trial registration DRKS, DRKS00013368. Registered Dec 04, 2017. Electronic supplementary material The online version of this article (10.1186/s12891-019-2723-9) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Sören Könneker
- Department of Plastic, Aesthetic, Hand and Reconstructive Surgery, Hanover Medical School (MHH), Carl-Neuberg-Straße 1, 30625, Hannover, Germany.
| | | | - Claudia Pieh
- Syntellix AG, Aegidientorplatz 2a, 30159, Hannover, Germany
| | - Christian von Falck
- Institute for Diagnostic and Interventional Radiology, Hanover Medical School, Carl-Neuberg-Str. 1, 30625, Hannover, Germany
| | | | - Peter M Vogt
- Department of Plastic, Aesthetic, Hand and Reconstructive Surgery, Hanover Medical School (MHH), Carl-Neuberg-Straße 1, 30625, Hannover, Germany
| | - Martin H Kirschner
- Syntellix AG, Aegidientorplatz 2a, 30159, Hannover, Germany.,Department for General, Trauma and Reconstructive Surgery, Ludwig-Maximilians University of Munich, Marchioninistraße 15, 81377, Munich, Germany
| | - Andreas Ziegler
- StatSol, Moenring 2, 23560, Lübeck, Germany. .,School of Mathematics, Statistics and Computer Science, University of KwaZulu-Natal, Pietermaritzburg, South Africa.
| |
Collapse
|
25
|
Van de Kleut ML, Yuan X, Athwal GS, Teeter MG. Validation of In Vivo Linear and Volumetric Wear Measurement for Reverse Total Shoulder Arthroplasty Using Model-Based Radiostereometric Analysis. J Orthop Res 2019; 37:1620-1627. [PMID: 30977541 DOI: 10.1002/jor.24294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Presently, polyethylene wear measurement of reverse total shoulder arthroplasty (rTSA) is restricted to in vitro, in silico, and retrieval analysis, with no method for the quantification of in vivo wear of well-functioning implants. The purpose of this study was to validate the use of model-based radiostereometric analysis (MBRSA) as a measurement tool for in vivo rTSA wear using a phantom setup. Six additively manufactured polyethylene inserts were fabricated, one unworn control and five to represent known wear patterns, and individually fit within the rTSA components. Each insert was imaged using standard radiostereometric techniques and analyzed using MBRSA. From the position and orientation estimation provided by MBRSA, a micro-computed tomography model of the control insert was virtually placed within the metaphyseal tray. The apparent intersection of the glenosphere into the insert was recorded as wear. This method enables wear measurements with a linear precision of 0.21 mm and a bias of 0.36 ± 0.13 mm, and a volumetric precision of 49.3 mm3 , with a bias of 48.9 ± 24.3 mm3 . This technique allows for the in vivo measurement of polyethylene wear without the requirement of marker beads or baseline radiographs, expanding the potential for in vivo wear measurements to larger populations and retrospective analysis. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1620-1627, 2019.
Collapse
Affiliation(s)
- Madeleine L Van de Kleut
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.,School of Biomedical Engineering, Western University, London, Ontario, Canada.,Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada
| | - Xunhua Yuan
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - George S Athwal
- Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada.,Department of Surgery, Division of Orthopaedic Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| | - Matthew G Teeter
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.,School of Biomedical Engineering, Western University, London, Ontario, Canada.,Lawson Health Research Institute, St. Joseph's Health Care, London, Ontario, Canada.,Department of Surgery, Division of Orthopaedic Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.,Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada
| |
Collapse
|
26
|
Lambert B, Neut D, van der Veen HC, Bulstra SK. Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature. INTERNATIONAL ORTHOPAEDICS 2018; 43:1549-1557. [PMID: 30470866 DOI: 10.1007/s00264-018-4237-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 11/14/2018] [Indexed: 02/04/2023]
Abstract
Highly cross-linked ultrahigh molecular weight polyethylene (UHMWPE) was introduced to decrease wear debris and osteolysis. During cross-linking, free radicals are formed, making highly cross-linked polyethylene vulnerable to oxidative degradation. In order to reduce this process, anti-oxidant vitamin E can be incorporated in polyethylene. This review provides an overview of the effects of vitamin E incorporation on major complications in total joint arthroplasty: material failure due to oxidative degradation, wear debris and subsequent periprosthetic osteolysis, and prosthetic joint infections. Secondly, this review summarizes the first clinical results of total hip and knee arthroplasties with vitamin E incorporated highly cross-linked polyethylene. Based on in vitro studies, incorporation of vitamin E in polyethylene provides good oxidative protection and preserves low wear rates. Incorporation of vitamin E may have the beneficial effect of reduced inflammatory response to its wear particles. Some microorganisms showed reduced adherence to vitamin E-incorporated UHMWPE; however, clinical relevance is doubtful. Short-term clinical studies of total hip and knee arthroplasties with vitamin E-incorporated highly cross-linked UHMWPE reported good clinical results and wear rates similar to highly cross-linked UHMWPE without vitamin E.
Collapse
Affiliation(s)
- Bart Lambert
- Department of Orthopedic Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands
| | - Daniëlle Neut
- Department of Biomedical Engineering, University of Groningen, University Medical Center Groningen, Antonius Deusinglaan 1, 9713 AV, Groningen, The Netherlands
| | - Hugo C van der Veen
- Department of Orthopedic Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
| | - Sjoerd K Bulstra
- Department of Orthopedic Surgery, University of Groningen, University Medical Center Groningen, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands
| |
Collapse
|
27
|
Singh G, Klassen R, Howard J, Naudie D, Teeter M, Lanting B. Manufacturing, oxidation, mechanical properties and clinical performance of highly cross-linked polyethylene in total hip arthroplasty. Hip Int 2018; 28:573-583. [PMID: 29998768 DOI: 10.1177/1120700018780677] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Ultra-high molecular weight polyethylene (UHMWPE) continues to be the gold standard bearing surface in total hip arthroplasty (THA) for nearly 5 decades. Highly cross-linked UHMWPE (HXLPE) was adapted for routine use in the early 2000s to reduce the revision rates related to wear, osteolysis, and aseptic loosening resulting from conventional UHMWPE wear. Since its inception, consistent evidence showing reduced wear rates and osteolysis supports the use of HXLPE in THA. High quality studies demonstrating the advantage in long term survivorship of HXLPE over conventional UHMWPE are emerging. Though retrieval studies have demonstrated evidence of in vivo oxidation and fatigue related damage at the rim of the first generation HXLPE liners, clinical significance of this remains to be seen. Second-generation sequentially annealed and vitamin E containing HXLPE liners demonstrate improved mechanical properties, resistance to oxidation, and equivalent wear rates in comparison to their first-generation counterparts, but long term success remains to be seen.
Collapse
Affiliation(s)
- Gurpreet Singh
- 1 Joint Replacement Institute, London Health Science Center (LHSC), University Hospital, Schulich School of Medicine, Western University, London, Ontario, Canada
| | - Robert Klassen
- 2 Department of Mechanical and Materials Engineering, Western University, London, Ontario, Canada
| | - James Howard
- 1 Joint Replacement Institute, London Health Science Center (LHSC), University Hospital, Schulich School of Medicine, Western University, London, Ontario, Canada
| | - Douglas Naudie
- 1 Joint Replacement Institute, London Health Science Center (LHSC), University Hospital, Schulich School of Medicine, Western University, London, Ontario, Canada
| | - Matthew Teeter
- 3 Joint Replacement Institute, LHSC, University Hospital, Department of Medical Biophysics, Western University, Surgical Innovation Program, Lawson Health Research Institute, London, Ontario, Canada
| | - Brent Lanting
- 1 Joint Replacement Institute, London Health Science Center (LHSC), University Hospital, Schulich School of Medicine, Western University, London, Ontario, Canada
| |
Collapse
|
28
|
Schipper ON, Haddad SL, Fullam S, Pourzal R, Wimmer MA. Wear Characteristics of Conventional Ultrahigh-Molecular-Weight Polyethylene Versus Highly Cross-Linked Polyethylene in Total Ankle Arthroplasty. Foot Ankle Int 2018; 39:1335-1344. [PMID: 30019605 DOI: 10.1177/1071100718786501] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The aim of this study was to compare the polyethylene wear rate, particle size, and particle shape of primary semiconstrained, fixed-bearing, bone-sparing total ankle arthroplasty using conventional ultrahigh-molecular-weight polyethylene (CPE) versus highly cross-linked polyethylene (HXLPE) by applying a level walking input using a joint simulator. METHODS Two fixed-bearing total ankle replacement systems with different types of polyethylene liners were tested: (1) CPE sterilized in ethylene oxide, and (2) HXLPE sterilized with gas plasma after electron beam irradiation. Three implants for each design underwent wear testing using gravimetric analysis over 5 million simulated walking cycles. A fourth implant was used as a load soak control. Equivalent circle diameter (ECD) and equivalent shape ratio (ESR) were computed to determine particle size and particle shape, respectively. RESULTS The mean wear rate from 1.5 to 5 million cycles (MC) was 2.0 ± 0.3 mg/MC for HXLPE and 16.7 ± 1.3 mg/MC for CPE ( P < .001). The total number of particles per cycle generated for HXLPE and CPE were 0.17 × 106 particles/cycle and 0.53 × 106 particles/cycle, respectively ( P < .001). The mean ECD of HXLPE particles (0.22 ± 0.11 μm) was significantly smaller than the mean ECD of CPE particles (0.32 ± 0.14 μm) ( P < .001). HXLPE particles were significantly more round than CPE particles ( P < .001). CONCLUSIONS HXLPE liners had a significantly lower wear rate and produced significantly fewer and rounder particles than CPE liners. The results of this study suggest that HXLPE has more favorable wear characteristics for total ankle arthroplasty. CLINICAL RELEVANCE Polyethylene wear particles have been linked to osteolysis after total ankle arthroplasty. There is no consensus on the importance of highly cross-linked polyethylene in total ankle arthroplasty with regard to implant wear. This is the first nonindustry study to compare the polyethylene wear rate, particle size, and particle shape of fixed-bearing total ankle arthroplasty conventional polyethylene versus highly cross-linked polyethylene. The lower wear rate and different particle size/morphology of highly cross-linked polyethylene could be beneficial in vivo to decrease osteolysis.
Collapse
Affiliation(s)
| | | | - Spencer Fullam
- 3 Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Robin Pourzal
- 3 Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Markus A Wimmer
- 3 Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
29
|
Christensen DD, Nelms NJ. Competitive Running After Total Hip Arthroplasty: The World's Fastest Total Hip: A Case Report. JBJS Case Connect 2018; 8:e81. [PMID: 30303849 DOI: 10.2106/jbjs.cc.18.00030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
CASE We report the case of a young man who underwent total hip arthroplasty (THA) for osteonecrosis at the age of 20 years, and subsequently competed in collegiate long-distance running. The pinnacle of his career was setting the school record time of 3:47.64 (min:sec) in the 1,500-m "metric mile" run (equivalent to 4:05.09 for the "English" mile). This is the fastest known time for any patient who has undergone THA. Excellent clinical and radiographic outcomes had been maintained at 6 years postoperatively. CONCLUSION Patients who undergo arthroplasty procedures may be capable of remarkable physical accomplishments, but pursuing such feats is not advised.
Collapse
Affiliation(s)
- David D Christensen
- Orthopaedic Surgery and Rehabilitation Department, University of Vermont, Burlington, Vermont
| | | |
Collapse
|
30
|
Bonutti PM, Mesko JW, Ramakrishnan R. Long-term Wear Data From a Prospective Multicenter Study of Second-Generation Highly Cross-linked Polyethylene Inserts in Total Hip Arthroplasty. Orthopedics 2018; 41:e529-e533. [PMID: 29771397 DOI: 10.3928/01477447-20180511-03] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2017] [Accepted: 02/26/2018] [Indexed: 02/03/2023]
Abstract
In a prospective multicenter trial on highly cross-linked polyethylene inserts in patients undergoing total hip arthroplasty, 118 patients consented to 10-year follow-up. Medium-term follow-up results showed low wear at 5 and 7 years after surgery. The current study focuses on long-term data at 10 years. Patients were followed up by either phone or office visit to collect long-term clinical data including Harris hip score and adverse events. There were 2 deaths and 2 revisions, 1 at 6.5 years for pelvic cyst and severe pain and another at 8.0 years for recurrent dislocation. For wear analysis, suitable radiographic images for 48 patients (52 hips) at minimum 10-year follow-up were available. Mean age of the cohort was 62.5 years (62% female). Femoral head penetration was measured using Martell's method from the radiographic images between the 6-week and the subsequent follow-ups. Polyethylene wear rate was calculated from the penetration data. Descriptive statistics were performed. There was no evidence of significant oxidation or locking mechanism failure. Mean Harris hip score of the group was 94.3. No osteolysis was noted by an independent radiographic reviewer. The slope of the bestfit regression line to the femoral head penetration data, which represents the overall linear wear rate of the polyethylene, was 0.014 mm/y. The wear rate was significantly below the 0.100 mm/y critical threshold for development of osteolysis. Volumetric wear rate was calculated to be 11.6 mm3/y. The second-generation highly cross-linked polyethylene acetabular inserts had low wear in the long term (10.3 years) with no incidence of osteolysis. [Orthopedics. 2018; 41(4):e529-e533.].
Collapse
|
31
|
Lachiewicz PF, O'Dell JA, Martell JM. Large Metal Heads and Highly Cross-Linked Polyethylene Provide Low Wear and Complications at 5-13 Years. J Arthroplasty 2018; 33:2187-2191. [PMID: 29588121 DOI: 10.1016/j.arth.2018.02.063] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 01/31/2018] [Accepted: 02/15/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Highly cross-linked polyethylene (XLPE) is reported to have low rates of linear and volumetric wear at 10-14 years. In a prior study, larger (36 and 40 mm) femoral heads were associated with more volumetric wear, but there were only 12 hips with these heads. METHODS We evaluated 107 hips (93 patients, with a mean age of 76 years) with one design of uncemented acetabular component, a 36 (90 hips) or 40 mm (17 hips) metal femoral head, and one electron beam 100 kGy irradiated and remelted XLPE at a mean follow-up of 8 years (range 5-13 years). Selection of these femoral heads was based on several factors, including the perceived risk of dislocation, the outer diameter size of the acetabular component, and liner availability. Measurements of linear and volumetric wear were performed in one experienced laboratory by the Martell method and analyzed using the first-to-last method. Standard radiographs, with additional Judet views, were used to detect periprosthetic osteolysis. Clinical records were used to determine the complications of dislocation, liner fracture, and painful trunnion corrosion. RESULTS For the entire cohort, the median linear wear rate was 0.041 mm/y (95% confidence interval, 0.031-0.057) and the median volumetric wear rate was 34.6 mm3/y (95% confidence interval, 31.4-53.5). With the numbers available, there was no difference in linear or volumetric wear between the 36 and 40 mm head sizes. Small, asymptomatic osteolytic lesions were noted in 3 hips (2%). There were 3 patients (3%) with dislocation (2 early and 1 late), but these have not had a revision. There were no revisions for loosening, no liner fracture, and no patient with symptomatic trunnion corrosion. CONCLUSION This acetabular component and XLPE with large metal heads had low rates of linear and volumetric wear. Large metal femoral heads did not lead to liner fracture, loosening, or symptomatic trunnion corrosion in this patient population. However, we recommend longer clinical follow-up studies and caution in the routine use of larger metal femoral heads in other, younger patient populations.
Collapse
Affiliation(s)
| | - Jane A O'Dell
- Chapel Hill Orthopedics Surgery & Sports Medicine, Chapel Hill, NC
| | - John M Martell
- Department of Orthopaedic Surgery and Rehabilitation Medicine, University of Chicago Medical Center, Chicago, IL
| |
Collapse
|
32
|
Park CH, Ha YC, Lee YK, Koo KH. Using Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty Necessitating 44- or 46-mm Metal Shells. Orthopedics 2018; 41:e354-e359. [PMID: 29570759 DOI: 10.3928/01477447-20180320-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2017] [Accepted: 12/15/2017] [Indexed: 02/03/2023]
Abstract
Ceramic-on-ceramic articulation shows the lowest wear, with a low incidence of osteolysis. A small cup limits options regarding liner thickness and femoral implant size. The purpose of this study was to evaluate the safety of a 4-mm-thick ceramic liner and the outcomes of cementless total hip arthroplasty using a 44- or 46-mm metal shell and a ceramic-on-ceramic bearing at mid- to long-term follow-up. Between May 2003 and June 2008, 80 patients (88 hips) who had hip osteoarthritis and a hypoplastic acetabulum underwent cementless total hip arthroplasty using a 44- or 46-mm metal shell and a ceramic-on-ceramic bearing. Sixty-eight of these patients (76 hips) were followed for an average of 8 years. The ceramic-related complications, clinical and radiological results, and Kaplan-Meier survivorship of these patients were evaluated. Mean Harris hip score had improved to 88 points (range, 49-100 points) at final follow-up. No ceramic fractures occurred during follow-up. All acetabular and femoral prostheses had bone ingrowth, and there was no measurable wear in any hip. In 1 patient, a radiolucent lesion occurred around the acetabular cup. Two hips underwent revision because of periprosthetic fractures. The survival rates of the acetabular cups and the femoral stems were 100% and 97.4%, respectively. The thin (4 mm) ceramic liner did not increase the risk of ceramic fracture and did not affect the mid- to long-term results and survival of cementless total hip arthroplasty using 44- or 46-mm metal shells. [Orthopedics. 2018; 41(3):e354-e359.].
Collapse
|
33
|
Gaudiani MA, Ranawat AS, Ranawat CS. Wear Analysis of Highly Cross-Linked Polyethylene in Young and Active Patients at Average Fourteen Years: A Concise Follow-Up of a Previous Report. J Arthroplasty 2018; 33:586-589. [PMID: 29066109 DOI: 10.1016/j.arth.2017.09.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 09/04/2017] [Accepted: 09/05/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Concerns persist regarding the oxidative stability of annealed highly cross-linked polyethylene (HXLPE) and hence its wear performance especially long term in young and active patients. The purpose of this study is to assess the wear rates and clinical outcomes of a first-generation annealed HXLPE. METHODS Forty-six patients (57 hips) with noncemented fixation, a mean age of 53 years, and a mean University of California Los Angeles activity score of 8 underwent primary total hip arthroplasty. A 28-mm femoral head against HXLPE liner was used in all cases. Linear wear rates were measured by 2 independent observers. Radiological and clinical assessments were recorded. RESULTS At a mean of 14 years (range 10-17), the wear rate was 0.03 mm/y (SD ±0.02). There were no revisions for wear-related complications. Using revision for wear-related complications as an endpoint, the survivorship was 100% and we observed no osteolysis. Western Ontario and McMaster Universities Osteoarthritis Index, patient administered questionnaire, and Hospital for Special Surgery hip scores were 91/100, 5/100, and 37/40 respectively. CONCLUSION This study confirms that a first-generation annealed HXLPE shows excellent wear and clinical results at 10-17 years in young and active patients. Oxidative degradation of an annealed HXLPE does not adversely affect wear and shows no other wear-related complications.
Collapse
Affiliation(s)
- Michael A Gaudiani
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | - Amar S Ranawat
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| | - Chitranjan S Ranawat
- Department of Orthopedic Surgery, Hospital for Special Surgery, New York, New York
| |
Collapse
|
34
|
Rochcongar G, Buia G, Bourroux E, Dunet J, Chapus V, Hulet C. Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty: A Prospective Randomized Controlled Trial. J Bone Joint Surg Am 2018; 100:107-114. [PMID: 29342060 DOI: 10.2106/jbjs.16.01379] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Aseptic loosening, the most common indication for revision surgery in total hip arthroplasty, can result from osteolysis caused by polyethylene (PE) wear particles. PE wear is increased by age-related oxidation of PE and free radicals emerging during irradiation cross-linking. Diffusion of vitamin E into PE stabilizes free radicals to maintain the biomechanical properties of PE. The purpose of this study was to determine whether vitamin E-infused highly cross-linked PE cups could reduce wear rates. METHODS We performed a prospective randomized controlled trial, in which 62 patients were allocated to 2 groups: a study group that received a vitamin E-infused highly cross-linked PE (HXLPE/VitE) cup and a control group that received an ultra-high molecular weight PE (UHMWPE) cup. Using radiostereometric analysis, we measured the penetration of the femoral head into the cup 7 days after surgery (baseline) and then again at 6 months and at 1, 2, and 3 years later. RESULTS Baseline variables did not differ significantly between the groups. At 1, 2, and 3 years after surgery, the HXLPE/VitE cup showed significantly less cumulative penetration (creep and wear) than the UHMWPE cup (p = 0.004, p < 0.0001, and p < 0.0001, respectively). The cumulative penetration after 3 years was 0.200 mm for the HXLPE/VitE cup versus 0.317 mm for the UHMWPE cup (p < 0.0001). From 1 to 3 years after surgery, after creep had stabilized and further penetration was mainly due to wear, the mean penetration increased only 0.04 mm in the HXLPE/VitE cup and 0.116 mm in the UHMWPE cup. CONCLUSIONS Our results confirm that wear rates over the first 3 years following surgery were lower in HXLPE/VitE cups than in UHMWPE cups. This suggests that HXLPE/VitE cups may prevent osteolysis, implant loosening, and eventually revision surgery. Long-term follow-up data continue to be collected to confirm these findings. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- G Rochcongar
- Department of Orthopedics and Traumatology, Caen University Hospital, Caen, France
| | - G Buia
- Department of Orthopedics and Traumatology, Caen University Hospital, Caen, France
| | - E Bourroux
- Department of Orthopedics and Traumatology, Caen University Hospital, Caen, France
| | - J Dunet
- Department of Orthopedics and Traumatology, Caen University Hospital, Caen, France
| | - V Chapus
- Department of Orthopedics and Traumatology, Caen University Hospital, Caen, France
| | - C Hulet
- Department of Orthopedics and Traumatology, Caen University Hospital, Caen, France
| |
Collapse
|
35
|
Wear rate and medium-term survival of a cemented, moderately cross-linked polyethylene acetabular prosthesis. Hip Int 2018; 28:53-58. [PMID: 29192734 DOI: 10.5301/hipint.5000521] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The moderately cross-linked Depuy Marathon® cemented acetabular component was introduced into the UK in 2007. The wear rate for the previously introduced Marathon® uncemented acetabular component has been reported to range from 0.06 to 0.01 mm/year. The aim of this study was to present the medium-term results and wear rate of the Marathon® cemented prosthesis used in primary total hip arthroplasty. METHODS 103 Marathon® cemented acetabular components were implanted between 2008 and 2009 in primary arthroplasty, who were eligible for this study. All patients received a metal 28-mm head. Mean age was 68 years (range 27-87). Mean clinical follow-up was 55 months (range 50-61). Mean radiological follow-up was 46 months (range 24-57). Wear was calculated on AP radiographs using computer-assisted uni-radiographic technique. RESULTS The mean wear was 0.37 mm (range 0.0-0.78 mm). The wear rate was calculated as 0.03 mm/year (95% confidence interval 0.02-0.06). Postoperative complications included deep vein thrombosis (2%) and dislocation (0.8%); there were no deep infections. There were no revisions for failure of the Marathon® cemented acetabular component. CONCLUSIONS The Marathon® cemented acetabular component demonstrates satisfactory wear rates and survivorship at medium-term follow-up.
Collapse
|
36
|
Morita D, Seki T, Higuchi Y, Takegami Y, Ishiguro N. Differences in Femoral Head Penetration Between Highly Cross-Linked Polyethylene Cemented Sockets and Uncemented Liners. J Arthroplasty 2017; 32:3796-3801. [PMID: 28781017 DOI: 10.1016/j.arth.2017.07.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/19/2017] [Revised: 06/02/2017] [Accepted: 07/12/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND This study aimed at investigating differences in femoral head penetration between highly cross-linked polyethylene (HXLPE) cemented sockets and uncemented liners during 5 years postoperatively. METHODS Ninety-six patients (106 hips) with a mean age of 64.4 (range, 35-83) years underwent total hip arthroplasty using a HXLPE cemented socket or liner and were respectively divided into cemented (35 patients [37 hips]) and uncemented (61 patients [69 hips]) groups. Femoral head penetrations were evaluated on both anteroposterior (AP)-view and Lauenstein-view radiographs, and mean polyethylene (PE) wear rates were calculated based on femoral head penetration from 2 to 5 years. Multivariate analyses were performed to assess risk factors for PE wear. RESULTS At 5 years postoperatively, the cemented and uncemented groups exhibited proximal direction femoral head penetrations of 0.103 mm and 0.124 mm (P = .226) and anterior direction penetrations of 0.090 mm and 0.151 mm (P = .002), respectively. The corresponding mean PE wear rates were 0.004 mm/y and 0.009 mm/y in the AP-view (P = .286) and 0.005 mm/y and 0.012 mm/y in the Lauenstein-view (P = .168), respectively. Left-side operation and high activity were independent risk factors for PE wear on AP-view. CONCLUSION When HXLPE was used, all mean PE wear rates were very low and those of cemented sockets and uncemented liners were very similar. PE particle theory suggests that the occurrence of osteolysis and related aseptic loosening might consequently decrease.
Collapse
Affiliation(s)
- Daigo Morita
- Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine, Nagoya City, Japan
| | - Taisuke Seki
- Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine, Nagoya City, Japan
| | - Yoshitoshi Higuchi
- Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine, Nagoya City, Japan
| | - Yasuhiko Takegami
- Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine, Nagoya City, Japan
| | - Naoki Ishiguro
- Department of Orthopedic Surgery, Nagoya University Graduate School of Medicine, Nagoya City, Japan
| |
Collapse
|
37
|
McKellop HA. Using Clinical Outcomes to Improve Preclinical Testing: Commentary on an article by Peter A. Devane, MBChB, MSc, FRACS, et al.: "Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty. A 10-Year Double-Blinded Randomized Controlled Trial". J Bone Joint Surg Am 2017; 99:e108. [PMID: 29040136 DOI: 10.2106/jbjs.17.00913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Affiliation(s)
- Harry A McKellop
- UCLA and Orthopaedic Institute for Children, Los Angeles, California
| |
Collapse
|
38
|
Oshima H, Tanaka S, Takatori Y, Tanaka T, Ishikura H, Moro T. Clinical and Radiographic Outcomes of Total Hip Arthroplasty With a Specific Liner in Small Asian Patients: Influence of Patient-Related, Implant-Related, and Surgical Factors on Femoral Head Penetration. J Arthroplasty 2017; 32:3065-3070. [PMID: 28579445 DOI: 10.1016/j.arth.2017.04.053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 03/23/2017] [Accepted: 04/24/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We evaluated the clinical and radiographic outcomes, including femoral head penetration, of total hip arthroplasty performed using a specific polyethylene (PE) liner in small Asian patients at 10 years after the index surgery. In addition, we investigated whether femoral head penetration was affected by patient-related, implant-related, and surgical factors. METHODS Between August 2002 and June 2005, for cementless primary total hip arthroplasty, we used acetabular PE liners that were manufactured from GUR 1050 resin, machined from isostatic compression-molded bar stock, and sterilized with a gamma ray irradiation in argon gas. We assessed 82 hips in 78 patients who received these liners. RESULTS The mean Harris hip score improved from 41.0 preoperatively to 84.5 at 10 years postoperatively. Periprosthetic osteolysis was observed in 7 hips (9.8%). No acetabular component migration was detected, and no revision surgery was performed 10 years postoperatively. The mean steady-state wear rate was 0.031 mm/y, which was lower than the wear rate for other conventional PE liners of the previous studies. Among the patient-related, implant-related, and surgical factors, sex was significantly associated with the mean steady-state wear rate, with a higher rate in male patients than in female patients. CONCLUSION PE acetabular liners used in small Asian patients show similar clinical outcomes and reduced wear compared with those of other liners. In addition, sex is significantly associated with the mean steady-state wear rate, and the steady-state wear rate is higher in male patients than in female patients.
Collapse
Affiliation(s)
- Hirofumi Oshima
- Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan; Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Sakae Tanaka
- Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Yoshio Takatori
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| | - Takeyuki Tanaka
- Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Hisatoshi Ishikura
- Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan
| | - Toru Moro
- Sensory & Motor System Medicine, Faculty of Medicine, The University of Tokyo, Tokyo, Japan; Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
| |
Collapse
|
39
|
Moro T, Takatori Y, Tanaka S, Ishihara K, Oda H, Kim YT, Umeyama T, Fukatani E, Ito H, Kyomoto M, Oshima H, Tanaka T, Kawaguchi H, Nakamura K. Clinical safety and wear resistance of the phospholipid polymer-grafted highly cross-linked polyethylene liner. J Orthop Res 2017; 35:2007-2016. [PMID: 27813260 DOI: 10.1002/jor.23473] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 10/28/2016] [Indexed: 02/04/2023]
Abstract
To reduce the production of wear particles and subsequent aseptic loosening, we created a human articular cartilage-mimicked surface for a highly cross-linked polyethylene liner, whose surface grafted layer consisted of a biocompatible phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine). Although our previous in vitro findings showed that poly(2-methacryloyloxyethyl phosphorylcholine)-grafted particles were biologically inert and caused no subsequent bone resorptive responses, and poly(2-methacryloyloxyethyl phosphorylcholine) grafting markedly decreased wear in hip joint simulator tests, the clinical safety, and in vivo wear resistance of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners remained open to question. Therefore, in the present study, we evaluated clinical and radiographic outcomes of poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners 5 years subsequent to total hip replacement in 68 consecutive patients. No reoperation was required for any reason, and no adverse events were associated with the implanted liners. The average Harris Hip Score increased from 38.6 preoperatively to 96.5 5 years postoperatively, and health-related quality of life, as indicated by the Short Form 36 Health Survey, improved. Radiographic analyses showed no periprosthetic osteolysis or implant migration. Between 1 and 5 years postoperatively, the mean steady-state wear rate was 0.002 mm/year, which represented a marked reduction relative to other highly cross-linked polyethylene liners, and appeared to be unaffected by patient-related or surgical factors. Although longer follow up is required, poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners improved mid-term clinical outcomes. The clinical safety and wear-resistance results are encouraging with respect to the improvement of long-term clinical outcomes with poly(2-methacryloyloxyethyl phosphorylcholine)-grafted highly cross-linked polyethylene liners. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2007-2016, 2017.
Collapse
Affiliation(s)
- Toru Moro
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.,Sensory and Motor System Medicine, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Yoshio Takatori
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Sakae Tanaka
- Sensory and Motor System Medicine, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Kazuhiko Ishihara
- Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan
| | - Hiromi Oda
- Department of Orthopaedic Surgery, Saitama Medical University School of Medicine, 38 Morohongo Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan
| | - Yoon Taek Kim
- Department of Orthopaedic Surgery, Saitama Medical University School of Medicine, 38 Morohongo Moroyama-machi, Iruma-gun, Saitama, 350-0495, Japan
| | - Takashige Umeyama
- Department of Orthopedic Surgery, NTT Medical Center Tokyo, 5-9-22 Higashigotanda, Shinagawa-ku, Tokyo, 141-0022, Japan
| | - Eisei Fukatani
- Department of Orthopaedic Surgery, JR Tokyo General Hospital, 2-1-3 Yoyogi, Shibuya-ku, Tokyo, 151-8528, Japan
| | - Hideya Ito
- Department of Orthopaedic Surgery, Japan Red Cross Medical Center, 4-1-22 Hiroo, Shibuya-ku, Tokyo, 150-8935, Japan
| | - Masayuki Kyomoto
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.,Department of Materials Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.,Department of Research, KYOCERA Medical Corporation, 3-3-31 Miyahara, Yodogawa-ku, Osaka, 532-0003, Japan
| | - Hirofumi Oshima
- Division of Science for Joint Reconstruction, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.,Sensory and Motor System Medicine, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Takeyuki Tanaka
- Sensory and Motor System Medicine, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Hiroshi Kawaguchi
- Japan Community Healthcare Organization, Tokyo Shinjuku Medical Center, Spine Center, 5-1 Tsukudo, Shinjuku-ku, Tokyo, 162-8543, Japan
| | - Kozo Nakamura
- Sensory and Motor System Medicine, Faculty of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.,Rehabilitation Services Bureau, National Rehabilitation Center for Persons With Disabilities, 4-1, Namiki, Tokorozawa, Saitama, 359-8555, Japan
| |
Collapse
|
40
|
Derbyshire B, Barkatali B. Validation of a new 2-D technique for radiographic wear measurement of cemented, highly cross-linked polyethylene acetabular cups. Med Eng Phys 2017; 47:159-166. [PMID: 28684212 PMCID: PMC5566276 DOI: 10.1016/j.medengphy.2017.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 05/22/2017] [Accepted: 06/01/2017] [Indexed: 11/04/2022]
Abstract
Mean wear penetration error of the system was −0.002 mm and the precision was 0.055 mm Above 0.25 mm penetration, wear direction error was within ±10° (median 1.15°) Good inter/intra observer agreement for clinical radiographs Penetration error equal to that of RSA for laboratory radiographs A new 2-D radiographic wear measurement system has been developed which enables the low wear of highly cross-linked polyethylene acetabular cups to be accurately and precisely measured from standard, pelvis radiographs. The software was validated using radiographic images of a measurement jig which could vary the cup orientation and simulate the effect of pelvic tilt/rotation. Wear was simulated using accurately measured plastic shims to vary the position of the femoral head relative to the cup. The effects of varying “wear” penetration, “wear” direction, cup orientation and X-ray focus position were assessed. Further direct comparison tests were also carried out using radiostereometric analysis. Inter/intra-observer repeatability of the new system was assessed using clinical radiographs. The mean (SD) “wear” penetration error was -0.002 mm (0.028 mm). The “wear” penetration precision was 0.055 mm. Changing the position of the X-ray focus point made no difference to the measurement error. Inter/intra-observer repeatability and limits of agreement had similar low values. Comparison tests with RSA showed the accuracy was similar.
Collapse
Affiliation(s)
- Brian Derbyshire
- Centre for Hip Surgery, Wrightington Hospital, Hall Lane, Appley Bridge, WN6 9EP, UK.
| | - Bilal Barkatali
- Centre for Hip Surgery, Wrightington Hospital, Hall Lane, Appley Bridge, WN6 9EP, UK.
| |
Collapse
|
41
|
Teeter MG, Yuan X, Somerville LE, MacDonald SJ, McCalden RW, Naudie DD. Thirteen-year wear rate comparison of highly crosslinked and conventional polyethylene in total hip arthroplasty: long-term follow-up of a prospective randomized controlled trial. Can J Surg 2017; 60:212-216. [PMID: 28570216 DOI: 10.1503/cjs.005216] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND The purpose of this study was to report the radiographic wear rates from a previous randomized controlled trial of first-generation highly crosslinked versus conventional polyethylene in total hip arthroplasty (THA) at a minimum of 13 years' follow-up. METHODS Patients returned for radiographic imaging and radiostereometric analysis (RSA). Radiographs were reviewed for the presence of osteolysis or component loosening. Femoral head penetration (which includes both wear and creep) was measured using RSA. We compared Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), 12-Item Short Form Health Survey (SF-12) and Harris Hip Scores (HHS) with preoperative values. RESULTS There was 1 revision in each group. There was no difference in WOMAC, SF-12, or HHS outcome scores between the highly crosslinked and conventional polyethylene groups (all p ≥ 0.13). Wear rate was lower with crosslinked polyethylene than conventional polyethylene (0.04 ± 0.02 mm/year v. 0.08 ± 0.03 mm/year, p = 0.007). CONCLUSION First-generation crosslinked polyethylene demonstrates greater wear resistance than conventional polyethylene after 13 years of implantation. Crosslinked polyethylene continues to outperform conventional polyethylene into the second decade of implantation.
Collapse
Affiliation(s)
- Matthew G Teeter
- From the Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ont. (Teeter, Somerville, MacDonald, McCalden, Naudie); the Surgical Innovation Program, Lawson Health Research Institute, London, Ont. (Teeter); and the Imaging Research Laboratories, Robarts Research Institute, London, Ont. (Yuan)
| | - Xunhua Yuan
- From the Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ont. (Teeter, Somerville, MacDonald, McCalden, Naudie); the Surgical Innovation Program, Lawson Health Research Institute, London, Ont. (Teeter); and the Imaging Research Laboratories, Robarts Research Institute, London, Ont. (Yuan)
| | - Lyndsay E Somerville
- From the Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ont. (Teeter, Somerville, MacDonald, McCalden, Naudie); the Surgical Innovation Program, Lawson Health Research Institute, London, Ont. (Teeter); and the Imaging Research Laboratories, Robarts Research Institute, London, Ont. (Yuan)
| | - Steven J MacDonald
- From the Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ont. (Teeter, Somerville, MacDonald, McCalden, Naudie); the Surgical Innovation Program, Lawson Health Research Institute, London, Ont. (Teeter); and the Imaging Research Laboratories, Robarts Research Institute, London, Ont. (Yuan)
| | - Richard W McCalden
- From the Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ont. (Teeter, Somerville, MacDonald, McCalden, Naudie); the Surgical Innovation Program, Lawson Health Research Institute, London, Ont. (Teeter); and the Imaging Research Laboratories, Robarts Research Institute, London, Ont. (Yuan)
| | - Douglas D Naudie
- From the Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ont. (Teeter, Somerville, MacDonald, McCalden, Naudie); the Surgical Innovation Program, Lawson Health Research Institute, London, Ont. (Teeter); and the Imaging Research Laboratories, Robarts Research Institute, London, Ont. (Yuan)
| |
Collapse
|
42
|
Currier BH, Van Citters DW. A Novel Technique for Assessing Antioxidant Concentration in Retrieved UHMWPE. Clin Orthop Relat Res 2017; 475:1356-1365. [PMID: 27334326 PMCID: PMC5384904 DOI: 10.1007/s11999-016-4939-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Antioxidants added to UHMWPE to prevent in vivo oxidation are important to the long-term performance of hip and knee arthroplasty. Diffused vitamin E antioxidant polyethylene raised questions about potential in vivo elution that could cause inflammatory reactions in periprosthetic tissues and also potentially leave the implant once again prone to oxidation. Currently, there is no information on the elution, if any, of antioxidants from implant polyethylene materials in vivo. QUESTIONS/PURPOSES (1) Do antioxidants, especially diffused vitamin E, elute from antioxidant polyethylene in vivo? (2) Can extraction of the retrieved antioxidant polyethylene (to remove absorbed species from the in vivo environment near the articular and nonarticular surfaces) improve the identification of antioxidant content? (3) Can actual antioxidant content be estimated from calculated antioxidant indices by accounting for ester content (from absorbed species) near the articular and nonarticular surfaces? METHODS An institutional review board-approved retrieval laboratory received 39 antioxidant polyethylene hip and knee retrievals at revision from 25 surgeons with in vivo time of 0.02 to 3.6 years (median, 1.3 years). These consecutive antioxidant polyethylene retrievals, received between May 2010 and February 2016, were made from three different antioxidant highly crosslinked polyethylene materials: diffused vitamin E, blended vitamin E, and hindered phenol antioxidant pentaerythritol tetrakis[3-(3,5-di-tert-butyl-4-hydroxyphenyl)] propionate (here and after referred to as PBHP). Retrievals were analyzed using Fourier transform infrared (FTIR) spectroscopy. Absorbed ester index (1725-1740 cm-1 normalized to 1365-1371 cm-1), and vitamin E index (1245-1275 cm-1) and PBHP index (1125-1150 cm-1), normalized to 1850-1985 cm-1, were defined. Microtomed thin sections of PBHP and vitamin E retrievals were hexane-extracted to remove absorbed species from the in vivo environment in an effort to improve identification of antioxidant content. Paired Student's t-tests were used to compare as-retrieved articular antioxidant index with expected antioxidant index (the bulk value for blended antioxidants where constant antioxidant content is expected throughout and the extrapolated original vitamin E concentration at the articular surface based on the as-manufactured vitamin E concentration gradient). Linear regression was used for each of the retrievals to evaluate the correlation of antioxidant index to ester content with the goal of extrapolation to the antioxidant index at zero ester content. RESULTS On average, vitamin E index at the articular surface (0.04 ± 0.03) was reduced compared with expected vitamin E index (0.09 ± 0.04; 95% confidence interval [CI] of the difference, 0.04-0.07; p < 0.001), and PBHP index at the articular surface (0.06 ± 0.02) was elevated compared with the average PBHP index from the bulk (0.03 ± 0.00; 95% CI of the difference, 0.03-0.05; p < 0.001). Extraction returned the PBHP index at the articular surface (0.03 ± 0.00) to bulk values (95% CI of the difference, -0.001 to 0.004; p = 0.326); diffused vitamin E was removed by extraction. Crossplots of vitamin E index and PBHP index with ester index showed significant (p < 0.001 for 32 of the 35 retrievals with sufficient data) linear trends (r ≥ 0.89) that allowed extrapolation of the articular surface antioxidant indices at zero absorbed ester index. CONCLUSIONS Absorbed esters from time in vivo caused erroneous values of antioxidant index to be calculated. However, hexane extraction to remove absorbed species also removed diffused vitamin E. Correlating antioxidant indices with ester content, measured by FTIR in unextracted antioxidant retrievals, provides a nonaltered method for estimating actual articular surface vitamin E index and demonstrates that there was no measurable elution in these short-term retrievals. CLINICAL RELEVANCE Assessing antioxidant content in retrieved polyethylene inserts is important to determine how much of the antioxidant remains in place to prevent oxidation of the polyethylene over time in vivo. Retrieval analyses reporting antioxidant content must account for absorbed species to be valid. Because standard hexane extraction removes both absorbed species and vitamin E from diffused vitamin E retrievals, the correlation method presented in this study is the recommended analysis alternative.
Collapse
Affiliation(s)
- Barbara H. Currier
- grid.254880.3Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH 03755 USA
| | - Douglas W. Van Citters
- grid.254880.3Thayer School of Engineering, Dartmouth College, 14 Engineering Drive, Hanover, NH 03755 USA
| |
Collapse
|
43
|
Yan Y, Chen H, Feng J, Chen K, Zhou K, Hong W, Wang Y, Liu Z, Zhang J, Yang Q, Guo L, He C. Poor performance of Enduron polyethylene liner in total hip arthroplasty: a minimum ten-year follow up and ultra-morphological analysis of wear particles. INTERNATIONAL ORTHOPAEDICS 2017; 41:723-730. [PMID: 27178441 DOI: 10.1007/s00264-016-3217-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2016] [Accepted: 04/25/2016] [Indexed: 11/29/2022]
Abstract
PURPOSE The aim of the present study was to investigate the long-term outcome and the wear characteristics of two distinct types of ultra-high molecular weight polyethylene (UHMWPE) liners in total hip arthroplasty (THA). METHODS We conducted a retrospective clinical study on patients which were treated with total hip arthroplasty using either Enduron polyethylene (Enduron PE) or Trilogy polyethylene (Trilogy PE) liners based on a minimum of ten year follow up data. Morphological analyses of wear particles from tissue samples, which were harvested during revision surgeries, were also performed. RESULTS A total of 79 THAs in the Enduron group and 55 THAs in the Trilogy group were available for analysis. Kaplan-Meier survival with revision for wear-related complications as the endpoint of the Enduron PE liners was lower than that of Trilogy PE liners at ten years (93.5 % and 100 %, P = 0.03). The Enduron group had higher mean linear wear rate than that of the Trilogy group (0.20 ± 0.09 and 0.09 ± 0.03 mm/year, P < 0.01). The incidence of osteolysis for the Enduron group was higher than that of the Trilogy group (33.3 % and 12 %, P = 0.04). Under transmission electron microscopy, the Enduron group had more than 82 % of the particles less than 1.0 μm in size and more than 57 % of the particles less than 0.5 μm. CONCLUSION The long-term performance of Enduron liners was worse than that of Trilogy liners. Further clinical follow-up may be necessary in patients with Enduron PE liners in order to avoid catastrophic complications.
Collapse
Affiliation(s)
- Yufei Yan
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Hao Chen
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Jianmin Feng
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Kaizhe Chen
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Kaidi Zhou
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Weixiang Hong
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Yi Wang
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Zhihong Liu
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Jiong Zhang
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Qingming Yang
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China
| | - Lei Guo
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China.
- Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, China.
| | - Chuan He
- Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Shanghai, China.
- Department of Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, People's Republic of China.
| |
Collapse
|
44
|
Broomfield JAJ, Malak TT, Thomas GER, Palmer AJR, Taylor A, Glyn-Jones S. The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort. J Arthroplasty 2017; 32:1186-1191. [PMID: 27998657 DOI: 10.1016/j.arth.2016.10.037] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2016] [Revised: 10/24/2016] [Accepted: 10/28/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography. METHODS Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized. RESULTS Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate. CONCLUSION This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene.
Collapse
Affiliation(s)
- John A J Broomfield
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Tamer T Malak
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Geraint E R Thomas
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Antony J R Palmer
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Adrian Taylor
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| | - Sion Glyn-Jones
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Botnar Research Centre, Oxford, United Kingdom
| |
Collapse
|
45
|
Haw JG, Battenberg AK, Huang DCT, Schmalzried TP. Wear Rates of Larger-Diameter Cross-Linked Polyethylene at 5 to 13 Years: Does Liner Thickness or Component Position Matter? J Arthroplasty 2017; 32:1381-1386. [PMID: 28007372 DOI: 10.1016/j.arth.2016.11.022] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 11/08/2016] [Accepted: 11/14/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Cross-linked polyethylene (XLPE) has demonstrated significantly reduced wear and osteolysis into the second decade for total hip arthroplasty. There is a relative paucity of data with ≥36-mm bearings. Issues include potential effects of reduced liner thickness and component position on wear, osteolysis, and mechanical failure of the bearing. METHODS Radiographs of 48 primary total hip arthroplasties with ≥36-mm modular XLPE bearings were analyzed at a minimum 5 years postoperative on serial radiographs using a validated, edge-detection-based algorithm. Subgroups were examined to assess the effect of bearing diameter, liner thickness, acetabular abduction angle, and acetabular anteversion on XLPE wear. RESULTS There was no significant difference in volumetric wear when subgroups were stratified by component factors: liner thickness (<6.5 mm vs ≥6.5 mm) 40.69 mm3/y vs 24.47 mm3/y, respectively (P = .315); acetabular component abduction angle (<45° vs ≥45°): 38.68 mm3/y vs 27.8 mm3/y, respectively (P = .522); acetabular anteversion (<20° vs ≥20°): 41.32 mm3/y vs 31.79 mm3/y, respectively (P = .521). There were no dislocations, mechanical failures, or revisions. There were 7 hips with volumetric wear rates ≥80 mm3/y; 1 had possible osteolysis. CONCLUSION Larger-diameter XLPE wear was not measurably affected by liner thickness, acetabular abduction angle, or acetabular anteversion. However, there is a trend for increasing volumetric wear with increasing bearing size. Wear outliers do occur, and continued follow-up of larger-diameter XLPE bearings is warranted.
Collapse
Affiliation(s)
- Jonathan G Haw
- Department of Orthopaedic Surgery, Harbor-UCLA Medical Center, Torrance, California
| | - Andrew K Battenberg
- Department of Orthopaedic Surgery, Harbor-UCLA Medical Center, Torrance, California
| | - Der-Chen T Huang
- Joint Replacement Institute at St. Vincent Medical Center, Los Angeles, California
| | - Thomas P Schmalzried
- Joint Replacement Institute at St. Vincent Medical Center, Los Angeles, California
| |
Collapse
|
46
|
Abstract
Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface. Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004.
Collapse
|
47
|
Alumina Delta-on-Alumina Delta Bearing in Cementless Total Hip Arthroplasty in Patients Aged <50 Years. J Arthroplasty 2017; 32:1048-1053. [PMID: 27919579 DOI: 10.1016/j.arth.2016.10.035] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Revised: 03/01/2016] [Accepted: 03/07/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND There are limited studies to evaluate long-term clinical and radiographic outcomes of alumina delta ceramic-on-ceramic bearings in cementless total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiographic results, prevalence of osteolysis, squeaking, and fracture of ceramic material associated with the use of the alumina delta ceramic-on-alumina delta ceramic bearing in cementless THA in patients aged <50 years. METHODS We reviewed the cases of 277 patients (334 hips) who underwent a cementless THA using alumina delta ceramic-on-alumina delta ceramic when they were 50 years or younger at the time of surgery. Demographic data; Harris Hip Score; Western Ontario McMaster Universities Osteoarthritis Index; and University of California, Los Angeles activity score were recorded. Radiographic and computerized tomographic evaluations were used to evaluate implant fixation and osteolysis. Squeaking sound and ceramic fracture were documented. The mean follow-up was 7.8 years (range, 6-9). RESULTS The mean postoperative Harris Hip Score, Western Ontario and McMaster Universities Osteoarthritis Index score, University of California, Los Angeles activity score were 93 points, 15 points, and 8.6 points, respectively. Two patients had thigh pain (grade 7 points). All acetabular components and all but 2 femoral components were well fixed. Thirty-three hips (10%) exhibited clicking sound, and 2 hips (0.6%) exhibited squeaking sound. No hip had osteolysis or ceramic head or liner fracture. CONCLUSION Our minimum 6-year follow-up results with the use of alumina delta ceramic-on-alumina delta ceramic bearings in patients aged <50 years suggest that cementless THA provides a high rate of survivorship without evidence of osteolysis or fracture of ceramic material.
Collapse
|
48
|
Currier BH, Currier JH, Holdcroft LA, Van Citters DW. Effectiveness of anti-oxidant polyethylene: What early retrievals can tell us. J Biomed Mater Res B Appl Biomater 2017; 106:353-359. [DOI: 10.1002/jbm.b.33840] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Revised: 12/06/2016] [Accepted: 12/10/2016] [Indexed: 11/05/2022]
Affiliation(s)
- Barbara H. Currier
- Thayer School of Engineering; Dartmouth College; Hanover New Hampshire 03755
| | - John H. Currier
- Thayer School of Engineering; Dartmouth College; Hanover New Hampshire 03755
| | | | | |
Collapse
|
49
|
Huang DY, Zhang L, Zhou YX, Zhang CY, Xu H, Huang Y. Total Hip Arthroplasty Using Modular Trabecular Metal Acetabular Components for Failed Treatment of Acetabular Fractures: A Mid-term Follow-up Study. Chin Med J (Engl) 2017; 129:903-8. [PMID: 27064033 PMCID: PMC4831523 DOI: 10.4103/0366-6999.179793] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background: Porous-coated cups have been widely used in acetabular reconstruction after failed treatment of acetabular fractures, and good results have been reported with the use of these cups; however, the durability and functionality of modular trabecular metal (TM) acetabular components in acetabular reconstruction after failed treatment of acetabular fractures remain unclear. This study aimed to examine the radiographic and clinical outcomes associated with the use of modular TM acetabular components for failed treatment of acetabular fractures to assess the durability and functionality of these components in acetabular reconstruction after failed treatment of acetabular fractures. Methods: A total of 41 patients (41 hips) underwent total hip arthroplasty (THA) using modular TM acetabular components for failed treatment of acetabular fractures at our hospital between January 2007 and December 2012. Among these patients, two were lost to follow-up. Therefore, 39 patients (39 hips) were finally included in this study. The Harris hip score before and after the surgery, satisfaction level of the patients, and radiographic results were assessed. Results: The mean Harris hip score increased from 34 (range, 8–52) before surgery to 91 (range, 22–100) at the latest follow-up examination (P < 0.001). The results were excellent for 28 hips, good for six, fair for three, and poor for two. Among the 39 patients, 25 (64%) and 10 (26%) were very satisfied and somewhat satisfied, respectively. All cups were found to be fully incorporated, and no evidence of cup migration or periacetabular osteolysis was noted. Conclusions: Despite the technically demanding nature of the procedure, THA using modular TM acetabular components showed good durability and functionality and may be an effective reconstruction option for failed treatment of acetabular fractures.
Collapse
Affiliation(s)
| | | | - Yi-Xin Zhou
- Department of Orthopedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing 100035, China
| | | | | | | |
Collapse
|
50
|
Gu X, He J, Tang Y, Zheng Y. Comparison of Polyethylene Wear before and after Hip Revision with Liner Exchange Fixed with the Original Locking Mechanism. PLoS One 2016; 11:e0167607. [PMID: 27935994 PMCID: PMC5147919 DOI: 10.1371/journal.pone.0167607] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2016] [Accepted: 10/26/2016] [Indexed: 12/03/2022] Open
Abstract
Objective To compare the wear of conventional ultra-high molecular weight polyethylene (CUHMWPE) and highly cross-linked polyethylene (HCLPE) in hip revision with liner exchange fixed with original locking mechanism using analysis of history medical data. Methods From Jan. 1, 2000, to Dec. 31, 2007, 26 patients (with 29 involved hips) underwent liner exchange revision fixed with the original locking mechanism due to wear of CUHMWPE and/or osteolysis. The mean age was 53 ± 9 years at the time of the primary total hip arthroplasty (THA) and 64 ± 9 years at the revision. The exchanged liners (Marathon, Depuy) were made of HCLPE. Annual X-rays were used to measure linear wear and osteolysis. The annual linear penetration was measured using PolyWare® software (Draftware Inc.). Annual Harris Hip Scores(HSS) were recorded. Results The mean follow-up time between the primary and revision THAs was 11 ± 2 years and 8 ± 2 years after revision. The mean Harris Hip Score(HHS) before primary THA, 1 year after primary THA, before revision and 1 year after revision was 43±5, 85±5, 71±6, 83±7 individually. The mean penetration of the CUHMWPE and HCLPE liners occurring in the first year were 0.44 ± 0.28 mm and 0.38 ± 0.14 mm, respectively (p = 0.211). The mean annual linear penetration of CUHMWPE and HCLPE from the second year onward were 0.29±0.09 mm and 0.08 ± 0.03 mm respectively (p <0.01). All THAs with CUHMWPE showed osteolysis on acetabular and/or femoral side before revision. No HCLPE liner showed osteolysis at the last follow-up. Conclusion: The CUHMWPE liner had a significantly higher wear rate than did the HCLPE liner. The HCLPE liner showed a satisfactory liner penetration rate after revision with isolated liner exchange fixed with the original locking mechanism.
Collapse
Affiliation(s)
- Xinfeng Gu
- Department of Orthopedics and Traumatology, Shuguang Hospital Affiliated to Shanghai University of Tradition Chinese Medicine, Shanghai, China
| | - Jie He
- Department of Orthopedics and Traumatology, Shuguang Hospital Affiliated to Shanghai University of Tradition Chinese Medicine, Shanghai, China
| | - Yiwen Tang
- Department of Orthopedics and Traumatology, Shuguang Hospital Affiliated to Shanghai University of Tradition Chinese Medicine, Shanghai, China
| | - Yuxin Zheng
- Department of Orthopedics and Traumatology, Shuguang Hospital Affiliated to Shanghai University of Tradition Chinese Medicine, Shanghai, China
- * E-mail:
| |
Collapse
|