1
|
D’Ambrosi R, Toni A, Czubak J, Guadilla J, Lieber L, Mariani I, Ursino N. Satisfactory clinical and radiologic outcomes with a new shorter and modular stem for end-stage hip osteoarthritis: an international prospective multicentre pilot study. SICOT J 2022; 8:9. [PMID: 35380533 PMCID: PMC8982177 DOI: 10.1051/sicotj/2022005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Accepted: 02/14/2022] [Indexed: 11/14/2022] Open
Abstract
INTRODUCTION This multicenter prospective cohort study aimed to assess the safety and clinical and radiologic performance of the CLS® BreviusTM Stem with Kinectiv® Technology. MATERIAL AND METHODS A total of 222 consecutive subjects, recruited in five different centers, qualifying for primary total hip arthroplasty (THA), were enrolled in the study. All the subjects received the CLS® BreviusTM Stem with Kinectiv® Technology. All the enrolled study subjects underwent pre-operative clinical and radiographic evaluation. Additionally, all subjects underwent post-operative clinical, functional and radiographic evaluations at 6 months and 1, 2, 3, and 5 years. These evaluations included implant survival, pain and functional performance (Harris Hip Score [HHS], University of California, Los Angeles [UCLA] Activity Score, Oxford Hip Score), subject quality-of-life (EQ-5D), radiographic parameters, complications, and concentration of metal ions (aluminum and titanium) in blood. RESULTS No revisions were performed during the follow-up period. Of the 222 patients, only 76 completed the 5-year follow-up. Only 7 and 5 patients had aluminum and titanium 5-year evaluations, respectively. All the clinical parameters showed an overall improvement in the overtime measured with ANOVA for repeated measures; furthermore, the clinical scores showed a statistically significant improvement at 5 years with respect to pre-operative value (p < 0.001). Aluminum and titanium showed no variation for repeated measures at different time points (p > 0.05). A total of six complications were reported, of which only two were hip-related. CONCLUSIONS The function of the CLS® BreviusTM Stem with Kinectiv® Technology indicated that subject well-being significantly increased following THA regardless of age, gender, BMI, previous surgery, primary diagnosis, and lifestyle.
Collapse
Affiliation(s)
| | - Aldo Toni
- IRCCS Istituto Ortopedico Rizzoli 40136 Bologna Italy
| | | | | | | | - Ilaria Mariani
- Institute for Maternal and Child Health – IRCCS “Burlo Garofolo” 34137 Trieste Italy
| | - Nicola Ursino
- IRCCS Istituto Ortopedico Galeazzi 20161 Milano Italy
| |
Collapse
|
2
|
Djebara AE, El Yagoubi A, Mertl P, El Fatayri B, Dehl M, Gabrion A. Comparison of periprosthetic bone mineral density between two types of short-stems in total hip arthroplasty with a mean follow-up of 4 years. Orthop Traumatol Surg Res 2022; 108:103044. [PMID: 34389498 DOI: 10.1016/j.otsr.2021.103044] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 12/17/2020] [Accepted: 01/04/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The use of short stems in primary hip arthroplasty has grown considerably in recent years, with a large variety of designs and stabilization methods available. Few studies have directly compared how these designs and fixation modes influence the bone mineral density (BMD) that is said to be better preserved with shorter implants. This led us to carry out a medium-term retrospective comparative study to (1) specify how the design of two different types of short stems influences the periprosthetic BMD, (2) compare the radiological and clinical outcomes of these stems. HYPOTHESIS The periprosthetic BMD of a short stem varies based on the implant's design. MATERIALS AND METHODS Ninety-three patients underwent total hip arthroplasty (THA) with a short stem between July 2012 and July 2014. Two groups of patients were formed: Vitae™ short stem (Adler Ortho, Milan, France), Optimys™ short stem (Mathys, Bettlach, Switzerland). The Vitae group consisted of 46 patients, while the Optimys group consisted of 47 patients. The mean age was 66 years, and the mean body mass index (BMI) was 26 kg/m2. The groups had comparable age, BMI, sex, Harris Hip score and preoperative radiological features. Periprosthetic BMD of the two types of implants was determined between the 1st and 4th year postoperative using dual-energy x-ray absorptiometry (DEXA) in the Gruen zones. The radiological and clinical outcomes were also determined. RESULTS There was a significant decrease in BMD in zone 7(-5.8%±0.1 CI95%[-0.09; -0.02] (p=0.003)), zone 2 (-4.8% ±0.1 CI95%[-0.093; -0.003] (p=0.038)) and zone 6 (-11% ±0.2 CI95%[-0.19; -0.03] (p=0.009)) in the patients with Vitae stems and in zone 2 (-13.7%±0.3 CI95%[-0.25; -0.03] (p=0.018)) in the patients with Optimys stems. A significant difference in BMD in zone 7 at 1 year (p=0.014) and 4 years (p=0.001) postoperative and in zone 6 (p=0.011) at 4 years postoperative existed between groups, with the Optimys group having higher BMD. There was a significant increase in femoral offset in the Optimys group but not the Vitae group: Δoffset=-0.50 mm±5.2 CI95%[-2.05; 1.05] (p=0.522) and Δoffset=2.79 mm±4.2 CI95%[1.21; 4.37] (p=0.001). The Harris Hip score was not significantly different between the two groups at 4 years postoperative (95.3±2.5 [88; 99] vs. 95.2±2.6 [88; 99] (p=0.991)). DISCUSSION The design of short stems appears to influence the distribution of loads and the periprosthetic BMD. These stems are associated with very good radiological and clinical results in the medium term. Bone remodeling appears to continue beyond 1 year after the THA procedure. LEVEL OF EVIDENCE III; Retrospective case-control study.
Collapse
Affiliation(s)
- Az-Eddine Djebara
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France.
| | - Abdelkader El Yagoubi
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Patrice Mertl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Bachar El Fatayri
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Massinissa Dehl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| | - Antoine Gabrion
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 80480 Salouël, France
| |
Collapse
|
3
|
Wang K, Kenanidis E, Gamie Z, Suleman K, Miodownik M, Avadi M, Horne D, Thompson J, Tsiridis E, Moazen M. The impact of stem fixation method on Vancouver Type B1 periprosthetic femoral fracture management. SICOT J 2022; 8:1. [PMID: 34989673 PMCID: PMC8734436 DOI: 10.1051/sicotj/2021064] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Accepted: 12/06/2021] [Indexed: 11/14/2022] Open
Abstract
INTRODUCTION Our understanding of the impact of the stem fixation method in total hip arthroplasty (THA) on the subsequent management of periprosthetic femoral fractures (PFF) is still limited. This study aimed to investigate and quantify the effect of the stem fixation method, i.e., cemented vs. uncemented THA, on the management of Vancouver Type B1 periprosthetic femoral fractures with the same plate. METHODS Eight laboratory models of synthetic femora were divided into two groups and implanted with either a cemented or uncemented hip prosthesis. The overall stiffness and strain distribution were measured under an anatomical one-legged stance. All eight specimens underwent an osteotomy to simulate Vancouver type B1 PFF's. Fractures were then fixed using the same extramedullary plate and screws. The same measurements and fracture movement were taken under the same loading conditions. RESULTS Highlighted that the uncemented THA and PFF fixation constructs had a lower overall stiffness. Subsequently, the mechanical strain on the fracture plate for the uncemented construct was higher compared to the cemented constructs. CONCLUSION PFF fixation of a Vancouver type B1 fracture using a plate may have a higher risk of failure in uncemented THAs.
Collapse
Affiliation(s)
- Katherine Wang
- Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK
| | - Eustathios Kenanidis
- Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK - Academic Orthopaedics Department, Papageorgiou General Hospital & CORE Lab at CIRI AUTH, Aristotle University Medical School, University Campus 54 124, Thessaloniki, Greece
| | - Zakareya Gamie
- Northern Institute for Cancer Research, Newcastle University, Framlington Place, Newcastle upon Tyne NE2 4HH, UK
| | - Khurram Suleman
- Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK
| | - Mark Miodownik
- Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK
| | - Mahsa Avadi
- DePuy Synthes, St. Anthony's Road, Leeds LS11 8DT, UK
| | - David Horne
- DePuy Synthes, St. Anthony's Road, Leeds LS11 8DT, UK
| | | | - Eleftherios Tsiridis
- Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK - Academic Orthopaedics Department, Papageorgiou General Hospital & CORE Lab at CIRI AUTH, Aristotle University Medical School, University Campus 54 124, Thessaloniki, Greece
| | - Mehran Moazen
- Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK
| |
Collapse
|
4
|
de Waard S, van der Vis J, Venema PAHT, Sierevelt IN, Kerkhoffs GMMJ, Haverkamp D. Short-term success of proximal bone stock preservation in short hip stems: a systematic review of the literature. EFORT Open Rev 2021; 6:1040-1051. [PMID: 34909223 PMCID: PMC8631238 DOI: 10.1302/2058-5241.6.210030] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Total hip arthroplasty is performed more frequently in younger patients nowadays, making long-term bone stock preservation an important topic. A mechanism for late implant failure is periprosthetic bone loss, caused by stress shielding around the hip stem due to different load distribution. Short stems are designed to keep the physical loading in the proximal part of the femur to reduce stress shielding. The aim of this review is to give more insight into how short and anatomic stems behave and whether they succeed in preservation of proximal bone stock. A systematic literature search was performed to find all published studies on bone mineral density in short and anatomic hip stems. Results on periprosthetic femoral bone mineral density, measured with dual-energy X-ray absorptiometry (DEXA), were compiled and analysed per Gruen zone in percentual change. A total of 29 studies were included. In short stems, Gruen 1 showed bone loss of 5% after one year (n = 855) and 5% after two years (n = 266). Gruen 7 showed bone loss of 10% after one year and –11% after two years. In anatomic stems, Gruen 1 showed bone loss of 8% after one year (n = 731) and 11% after two years (n = 227). Gruen 7 showed bone loss of 14% after one year and 15% after two years. Short stems are capable of preserving proximal bone stock and have slightly less proximal bone loss in the first years, compared to anatomic stems. Cite this article: EFORT Open Rev 2021;6:1040-1051. DOI: 10.1302/2058-5241.6.210030
Collapse
Affiliation(s)
- Sheryl de Waard
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands.,Academic Medical Centre (AMC), Amsterdam, Netherlands
| | - Jacqueline van der Vis
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Pascale A H T Venema
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | - Inger N Sierevelt
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| | | | - Daniël Haverkamp
- Specialized Centre of Othopedic Research & Education (SCORE) and Xpert Orthopedie, Amsterdam, Netherlands
| |
Collapse
|
5
|
Kiuttu J, Lehenkari P, Leskelä HV, Yrjämä O, Ohtonen P, Valkealahti M. Intra-operative Clodronate Rinsing Improves the Integration of the Femoral Stem in a Prospective, Double-blinded, Randomized, Placebo-controlled Clinical RSA-study. Open Orthop J 2021. [DOI: 10.2174/1874325002115010001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
Abstract
Background:
Periprosthetic bone loss after Total Hip Arthroplasty (THA), detected as an early migration of the prosthesis may predict later loosening of the implant.
Objective:
We hypothesized that intra-operative bisphosphonate rinsing would reduce bone resorption after THA. It might therefore be possible to achieve better early fixation of the implant.
Methods:
Nineteen patients suffering from arthrosis were recruited in a prospective, double-blinded, randomized, placebo-controlled clinical pilot trial. Patients were operated with an uncemented Bimetric stem using tantalum markers. The femoral proximal intramedullary canal was rinsed with 1mM clodronate in nine patients and with saline in 10 patients. These patients were followed for two years using radiostereometric analysis (RSA), dual energy x-ray absorptiometry (DXA) and the Harris Hip Score (HHS).
Results:
We did not found any significant differences between the study groups with regards to the primary output measures (maximum total point motion, MTPM). However, there was evidence that clodronate could affect periprosthetic bone quality; a beneficial effect in BMD in Gruen zone 3 during the two-year follow-up was observed, BMD decreased less in the clodronate group (p = 0.02). The maximal x-translation of the stem at 3-24 months was significantly two-fold, being higher in the placebo group (p = 0.02). The baseline BMD and the maximal total point motion (MTPM) at 3-24 months showed a positive correlation in the clodronate group and a negative correlation in the placebo group.
Conclusion:
In conclusion, further studies with larger patient groups and longer follow-up periods are needed to estimate the clinical importance of these findings and further to prove if an intraoperative clodronate rinsing prior to application of femoral stem during THA can prevent periprosthetic bone loss.
Clinical Trial Registration No.: NCT03803839
Collapse
|
6
|
Meyer JS, Freitag T, Reichel H, Bieger R. Mid-term gender-specific differences in periprosthetic bone remodelling after implantation of a curved bone-preserving hip stem. Orthop Traumatol Surg Res 2020; 106:1495-1500. [PMID: 33132094 DOI: 10.1016/j.otsr.2020.04.023] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 04/10/2020] [Accepted: 04/17/2020] [Indexed: 02/03/2023]
Abstract
BACKGROUND The implant-specific periprosthetic bone remodelling in the proximal femur is considered to be an important factor influencing the long-term survival of cementless hip stems. Particularly data of gender-specific differences regarding bone-preserving stems are very rare in literature and mainly limited to short-term investigations. Therefore, we investigated at mid-term one arm of a prospective randomised study to evaluate if there is an influence of gender on implant-specific stress shielding after implantation of a curved bone preserving hip stem (Fitmore) 5 years postoperatively. HYPOTHESIS We hypothesised there will be no gender-specific differences in periprosthetic bone remodelling. PATIENTS AND METHODS A total of 20 female and 37 male patients underwent total hip arthroplasty using the Fitmore stem. Clinical, radiological as well as osteodensitometric examinations were performed preoperatively, 7 days and 3, 12 and 60 months postoperatively. Clinical data collection included the Western Ontario and McMaster Universities Arthritis Index (WOMAC) and the Harris Hip Score (HHS). Periprosthetic bone mineral density (BMD) was measured using Dual Energy X-ray Absorptiometry (DXA) and the periprosthetic bone was divided into 7 regions of interest (ROI) for analysis. The results at 3, 12 and 60 months were compared with the first postoperative measurement after 7 days to obtain a percentage change. RESULTS Periprosthetic BMD showed a decrease in all 7 ROIs for both groups 5 years postoperatively referred to the baseline value, except ROI 3 (0.8%, p=0.761), representing the distal lateral part of the stem, and ROI 5 (0.3%, p=0.688), representing the distal medial part of the stem in the male cohort. Significant gender differences were found in ROI 1 (-16.0% vs. -3.5%, p=0.016) and ROI 6 (-9.9% vs. -2.1%, p=0.04) in favour of the male patients. Clinical results showed no significant gender differences 5 years postoperatively with regard to WOMAC (mean 0.4 (±0.8, 0-3.3) in women vs. 0.3 (±0.8, 0-4.2) in men, p=0.76) and HHS (mean 93.0 (±9.7, 66.0-100.0) in women vs. 93.9 (±11.5, 53.0-100.0) in men, p=0.36). CONCLUSION Proximal stress shielding was observed independent of gender 5 years postoperatively. However, there was a significantly lower bone loss proximal lateral and medial below the calcar in male patients, indicating a more physiological load transfer. [ClinicalTrials.gov identifier: NCT03147131 (Study ID D.3067-244/10). Registered 10 May 2017 - retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT03147131?term=Bieger&draw=2&rank=1] LEVEL OF EVIDENCE: IV; prospective study without control group.
Collapse
Affiliation(s)
- Julian Stefan Meyer
- Department of orthopaedic surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany; Department of orthopaedic surgery, Koenig-Ludwig-Haus, University of Wuerzburg, Brettreichstraße 11, 97074 Wuerzburg, Germany.
| | - Tobias Freitag
- Department of orthopaedic surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
| | - Heiko Reichel
- Department of orthopaedic surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
| | - Ralf Bieger
- Department of orthopaedic surgery, University of Ulm, Oberer Eselsberg 45, 89081 Ulm, Germany
| |
Collapse
|
7
|
Klug A, Gramlich Y, Hoffmann R, Pfeil J, Drees P, Kutzner KP. Trends in Total Hip Arthroplasty in Germany from 2007 to 2016: What Has Changed and Where Are We Now? ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2019; 159:173-180. [PMID: 31711254 DOI: 10.1055/a-1028-7822] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
BACKGROUND The number of total hip arthroplasties (THA) is rising in many industrialized nations. At the same time, the evidence regarding different types of prostheses and fixation techniques is constantly evolving. Therefore, this study aimed to analyze changes in THA by these advancements during the last decade. METHODS A retrospective analysis of data provided by the Federal Statistical Office of Germany from 2007 to 2016 was conducted using codes from the German procedure classification system and associated International Statistical Classification of Diseases and Related Health Problems codes. THA procedures were evaluated according to diagnoses, sex, and age of patients, along with the distribution of different prosthesis types. Additionally, changes in these parameters over time were analyzed. RESULTS From 2007 to 2016 a total of 2 157 041 primary THA procedures were performed in Germany, with an increase of 14.4% over this period. Overall, cementless standard THA (STHA) was used most frequently (50.0%), followed by hybrid variants (18.8%), hemiarthroplasties (15.9%), cemented standard THA (cSTHA; 9.2%), cementless short-stem THA (ssTHA; 4.8%), and hip resurfacing (HR; 0.9%) techniques. During the study period, the number of cSTHA and HR decreased significantly, whereas the use of STHA and ssTHA rose substantially, with a significantly higher application of these procedures in the elderly population. While osteoarthritis of the hip joint was the main indication for THA, several procedure-specific differences were identified. CONCLUSION The present data clearly demonstrate an increase in the use of cementless fixation for THA in Germany during the last decade and document a rise in ssTHA in recent years with, in contrast, the use of HR decreasing to a minimum.
Collapse
Affiliation(s)
- Alexander Klug
- Unfallchirurgie und Orthopädische Chirurgie, BG Unfallklinik Frankfurt am Main
| | - Yves Gramlich
- Unfallchirurgie und Orthopädische Chirurgie, BG Unfallklinik Frankfurt am Main
| | - Reinhard Hoffmann
- Unfallchirurgie und Orthopädische Chirurgie, BG Unfallklinik Frankfurt am Main
| | - Joachim Pfeil
- Klinik für Orthopädie und Unfallchirurgie, St. Josefs Hospital Wiesbaden
| | - Philipp Drees
- Zentrum für Orthopädie und Unfallchirurgie (ZOU), Universitätsmedizin Mainz
| | - Karl Philipp Kutzner
- Klinik für Orthopädie und Unfallchirurgie, St. Josefs Hospital Wiesbaden.,Zentrum für Orthopädie und Unfallchirurgie (ZOU), Universitätsmedizin Mainz
| |
Collapse
|
8
|
Kutzner KP, Donner S, Loweg L, Rehbein P, Dargel J, Drees P, Pfeil J. Mid-term results of a new-generation calcar-guided short stem in THA: clinical and radiological 5-year follow-up of 216 cases. J Orthop Traumatol 2019; 20:31. [PMID: 31673809 PMCID: PMC6823459 DOI: 10.1186/s10195-019-0537-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 08/23/2019] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND In recent years, a variety of short stems have been introduced. To date, mid- and long-term results of calcar-guided short-stem designs have been rarely available. MATERIALS AND METHODS Two hundred and sixteen calcar-guided short stems were included in combination with a cementless cup in a prospective study. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) as well as pain and satisfaction on visual analogue scale (VAS) were assessed during a median follow-up of 61.7 months. Standardised radiographs were analysed at predefined time points regarding radiological alterations such as bone resorption and remodelling, radiolucency, osteolysis and cortical hypertrophy using modified Gruen zones. RESULTS At mid-term follow-up, no revision surgery of the stem had to be performed in the whole collective. At 5 years, HHS was 97.8 (SD 4.7), satisfaction on VAS was 9.7 (SD 0.7), rest pain on VAS was 0.1 (SD 0.5), and load pain on VAS was 0.6 (SD 1.2). Compared to the 2-year results, femoral bone resorption increased significantly at the 5-year follow-up (3.9% versus 42.3%). Rate of femoral cortical hypertrophy remained stable, occurring in a total of 9 hips (4.5%). At the 5-year follow-up, 2 stems (1.0%) showed non-progressive radiolucent lines with a maximum width of 2 mm. Signs of osteolysis were not observed. Compared to the 2-year follow-up, no further subsidence was observed. CONCLUSIONS The rate of stem revision (0%) at the mid-term follow-up was remarkable and indicates the principle of using a calcar-guided short stem as being a safe procedure. However, signs of bone-remodelling, indicating some amount of stress-shielding, must be acknowledged at 5 years depending on stem alignment and type of anchorage. LEVEL OF EVIDENCE IV, Prospective observational study Trial registration German Clinical Trials Register, DRKS00012634, 07/07/2017 (retrospectively registered).
Collapse
Affiliation(s)
- Karl Philipp Kutzner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany. .,Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany.
| | - Stefanie Donner
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Lennard Loweg
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department for Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Joachim Pfeil
- Department of Orthopaedic Surgery and Traumatology, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| |
Collapse
|
9
|
von Engelhardt LV, Breil-Wirth A, Kothny C, Seeger JB, Grasselli C, Jerosch J. Long-term results of an anatomically implanted hip arthroplasty with a short stem prosthesis (MiniHip TM). World J Orthop 2018; 9:210-219. [PMID: 30364820 PMCID: PMC6198291 DOI: 10.5312/wjo.v9.i10.210] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 06/17/2018] [Accepted: 06/28/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the clinical and radiological outcome nine and ten years after short-stemmed, bone preserving and anatomical hip arthroplasty with the MiniHipTM system.
METHODS In a prospective study, 186 patients underwent hip arthroplasty with a partial neck preserving short stem (MiniHipTM, Corin). Elderly patients were not excluded from this study, thus the mean age at the time of surgery was 59.3 years (range 32 to 82 years). Surgery and the follow-up assessments were performed at two Centers. Up until now, the mean follow-up was 112.5 ± 8.2 mo. The Oxford Hip Score (OHS) and the Hip Dysfunction Osteoarthritis and Outcome Score (HOOS) was assessed pre- and each year after surgery. The clinical follow-up was accompanied by standardized a.p. and axial radiological examinations. Periprosthetic lucencies, hypertrophies within the Gruen zones one to fourteen were assessed. A subsidence of the stem was investigated according to Morray and heterotopic ossifications were assessed according to Brooker.
RESULTS The OHS and HOOS improved from 18 ± 3.3 to 46 ± 2.0 and from 30 ± 8.3 to 95 ± 4.6 points, P < 0.001 respectively. There were no differences regarding age, etiology, friction pairings, etc., (P > 0.05). Two stems were revised due to a symptomatic subsidence four and twelve months postoperatively. Thus, the survivorship for aseptic loosening at nine to ten years was 98.66%. Including one stem revision due to a symptomatic exostosis, bursitis and thigh pain as well as one revision because of a septic stem loosening, the overall survival for the stem with revision for any reason was 97.32%. Besides one asymptomatic patient, radiological signs of a proximal stress-shielding, such as bone resorptions within the proximal Gruen zones, were not noticed. Findings suggesting a distal loading, e.g., bony hypertrophies or bone appositions of more than 2 mm, were also not detected.
CONCLUSION Regarding these first long-term results on the MiniHipTM, the implant performed exceedingly well with a high rate of survivorship for aseptic loosening. Our radiological results within the Gruen zones support the design rationale of the Minihip to provide a reliable metaphyseal anchoring with the expected proximal, more physiological load transfer. This might minimize or exclude a stress shielding which might be associated with thigh pain, proximal bone loss and an increased risk of aseptic loosening. The MiniHipTM is a reliable partial-neck retaining prosthesis with good a clinical long-term outcome in younger as well as elderly patients.
Collapse
Affiliation(s)
- Lars V von Engelhardt
- Faculty of Health, University of Witten/Herdecke, Witten 58448, Germany
- Department of Trauma Surgery Orthopedics and Sports Medicine, Katholisches Karl-Leisner Klinikum, Kleve 47533, Germany
| | - Andreas Breil-Wirth
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
| | | | - Jörn Bengt Seeger
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg, Giessen 35392, Germany
| | - Christian Grasselli
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
- Department of Orthopaedics and Traumatology, Waldburg-Zeil Clinic Tettnang, Tettnang 88069, Germany
| | - Joerg Jerosch
- Department of Orthopedics, Trauma Surgery and Sports Medicine, Johanna Etienne Hospital, Neuss 41462, Germany
| |
Collapse
|
10
|
Said HG, El-Radi MA, Hassanein MY, Said GZ. Orthopaedic publications from Egypt in the last five years: a bibliometric report. INTERNATIONAL ORTHOPAEDICS 2018; 42:2507-2511. [DOI: 10.1007/s00264-018-4152-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2018] [Accepted: 09/06/2018] [Indexed: 12/11/2022]
|
11
|
Augustin L, Boller S, Bobach C, Jahnke A, Ahmed GA, Rickert M, Ishaque BA. Development of periprosthetic bone mass density around the cementless Metha® short hip stem during three year follow up-a prospective radiological and clinical study. INTERNATIONAL ORTHOPAEDICS 2018; 43:2031-2037. [PMID: 30178069 DOI: 10.1007/s00264-018-4126-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Accepted: 08/21/2018] [Indexed: 01/25/2023]
Abstract
PURPOSE The purpose of this study was to check the concept of the cementless Metha® short hip stem in order to find out whether proximal physiological load transfer can be achieved. METHODS Fourty-three patients were included. Epidemiological factors were established. The Harris Hip Score was determined and measurement of bone mass density as well as osteodensitometric and radiological measurements was carried out pre-operatively, post-operatively, and after six, 12, 24, and 36 months. RESULTS Harris Hip Score improved from 55.9 ± 12.4 pre-operatively to 94.8 ± 8.2 after 36 months (p < 0.001). After initial reduction of bone density in zones 1 and 7 up to six months post-operatively, there was a steady approximation of bone density to the initial values (p < 0.05). CONCLUSION The Metha® short hip stem shows good clinical results. Furthermore, there is an increase of bone density in the proximal zones 1 and 7 between six and 36 months serving as a sign of physiological load transfer.
Collapse
Affiliation(s)
- Laura Augustin
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Sarah Boller
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Cathrein Bobach
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Alexander Jahnke
- Laboratory of Biomechanics, Justus-Liebig-University Giessen, Klinikstraße 29, 35392, Giessen, Germany
| | - Gafar Adam Ahmed
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Markus Rickert
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany
| | - Bernd Alexander Ishaque
- Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, 35392, Giessen, Germany.
| |
Collapse
|
12
|
Yan SG, Weber P, Steinbrück A, Hua X, Jansson V, Schmidutz F. Periprosthetic bone remodelling of short-stem total hip arthroplasty: a systematic review. INTERNATIONAL ORTHOPAEDICS 2017; 42:2077-2086. [DOI: 10.1007/s00264-017-3691-z] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2017] [Accepted: 11/09/2017] [Indexed: 01/26/2023]
|