World J Radiology. Mar 28, 2019; 11(3): 46-54
Published online Mar 28, 2019. doi: 10.4329/wjr.v11.i3.46
Published online Mar 28, 2019. doi: 10.4329/wjr.v11.i3.46
Ref. | Published date | Authors | Highlights of detailed data |
[21] | 2003 | Remouchamps et al | The use of mDIBH reduced the mean percentage of both lungs receiving more than 20 Gy from 20.4% to 15.2% (P < 0.00007) |
[22] | 2015 | Muralidhar et al | The mean difference of right lung volume receiving more than 20 Gy of the dose was from 1% to -98 % (IGRT < 0.24556) |
[26] | 2003 | Hof et al | In the craniocaudal direction the mean tumor movement was 5.1 mm , in the ventrodorsal direction 3.1 mm, and in the lateraldirection 2.6 mm |
[31] | 2017 | Tan et al | The errors of image-guided registration using 4D-CBCT and 3D-CBCT on the X, Y, Z axes, and 3D space were 0.80 ± 0.21 mm and 1.08 ± 0.25 mm, 2.02 ± 0.46 mm and 3.30 ± 0.53 mm, 0.52 ± 0.16 mm and 0.85 ± 0.24 mm, and 2.25 ± 0.44 mm and 3.59 ± 0.48 mm (all P < 0.001), respectively |
[32] | 2017 | Ehrbar et al | Compared with the 4D dose calculations, the mid-ventilation and single-phase tracking overestimated the target mean dose (2.3% and 1.3%), respectively |
[34] | 2016 | Garibaldi | The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively |
[7] | 2016 | Wang et al | Position errors after correction in Left–right, Anterior–posterior and Cranial–caudal were 0.22 cm, 0.16 cm and 0.19 cm, respectively |
[36] | 2016 | Ariyaratne et al | Under the use of IGRT, the population mean setup error was 0.01 cm (left–right), 0.05 cm (supero-inferior) and 0.13 cm (antero-posterior) |
- Citation: Ren XC, Liu YE, Li J, Lin Q. Progress in image-guided radiotherapy for the treatment of non-small cell lung cancer. World J Radiology 2019; 11(3): 46-54
- URL: https://www.wjgnet.com/1949-8470/full/v11/i3/46.htm
- DOI: https://dx.doi.org/10.4329/wjr.v11.i3.46