For: | Palmucci S, Mauro LA, Messina M, Russo B, Failla G, Milone P, Berretta M, Ettorre GC. Diffusion-weighted MRI in a liver protocol: Its role in focal lesion detection. World J Radiol 2012; 4(7): 302-310 [PMID: 22900131 DOI: 10.4329/wjr.v4.i7.302] |
---|---|
URL: | https://www.wjgnet.com/1949-8470/full/v4/i7/302.htm |
Number | Citing Articles |
1 |
Marwa Romeih, Mary R Mahrous, Mohamed El Kassas. Incidental radiological findings suggestive of COVID-19 in asymptomatic patients. World Journal of Radiology 2022; 14(1): 1-12 doi: 10.4329/wjr.v14.i1.1
|
2 |
Francesco Papa, Ambra Santonocito, Marco Gatti, Riccardo Faletti. A Practical Guide to Advanced Diffusion MRI. 2024; : 171 doi: 10.1007/978-3-031-70337-9_7
|
3 |
Stefano Palmucci. Focal liver lesions detection and characterization: The advantages of gadoxetic acid-enhanced liver MRI. World Journal of Hepatology 2014; 6(7): 477-485 doi: 10.4254/wjh.v6.i7.477
|
4 |
Guibin Wang, Shicai Zhu, Xiukui Li. Comparison of values of CT and MRI imaging in the diagnosis of hepatocellular carcinoma and analysis of prognostic factors. Oncology Letters 2018; doi: 10.3892/ol.2018.9690
|
5 |
Timothy J. Allen, Rianne A. van der Heijden, Gregory Simchick, Diego Hernando. Reproducibility of liver ADC measurements using first moment optimized diffusion imaging. Magnetic Resonance in Medicine 2024; doi: 10.1002/mrm.30372
|
6 |
Roh-Eul Yoo, Jeong Min Lee, Jeong Hee Yoon, Jung Hoon Kim, Joon Koo Han, Byung Ihn Choi. Differential diagnosis of benign and malignant distal biliary strictures: Value of adding diffusion-weighted imaging to conventional magnetic resonance cholangiopancreatography. Journal of Magnetic Resonance Imaging 2014; 39(6): 1509 doi: 10.1002/jmri.24304
|
7 |
Ping Ni, Yuning Lin, Qun Zhong, Ziqian Chen, Kumar Sandrasegaran, Chen Lin. Technical advancements and protocol optimization of diffusion-weighted imaging (DWI) in liver. Abdominal Radiology 2016; 41(1): 189 doi: 10.1007/s00261-015-0602-x
|
8 |
Anita Wale, Heather Harris, Gina Brown. Diagnostic Certainty in Characterizing Liver Lesions in Rectal Cancer: Abbreviated Liver MRI versus CT. Annals of Surgical Oncology 2025; doi: 10.1245/s10434-024-16468-2
|
9 |
Valérie Vilgrain, Maxime Esvan, Maxime Ronot, Aurore Caumont-Prim, Christophe Aubé, Gilles Chatellier. A meta-analysis of diffusion-weighted and gadoxetic acid-enhanced MR imaging for the detection of liver metastases. European Radiology 2016; 26(12): 4595 doi: 10.1007/s00330-016-4250-5
|
10 |
Jae-Seung Lee, In-Chul Im, Su-Man Kang, Eun-Hoe Goo, Kwang Kim. A quantitative evaluation of diffusion-weighted MR imaging of focal hepatic lesions by using an optimal b-value for differentiation of malignant and benign tumors. Journal of the Korean Physical Society 2013; 63(11): 2226 doi: 10.3938/jkps.63.2226
|
11 |
Maxime Barat, Philippe Soyer, Raphael Dautry, Marc Pocard, Rea Lo Dico, Haythem Najah, Clarisse Eveno, Christophe Cassinotto, Anthony Dohan. Preoperative detection of malignant liver tumors: Comparison of 3D-T2-weighted sequences with T2-weighted turbo spin-echo and single shot T2 at 1.5 T. European Journal of Radiology 2018; 100: 7 doi: 10.1016/j.ejrad.2018.01.007
|
12 |
Maryam Ghadimi, Roya Rezvani Habibabadi, Bita Hazhirkarzar, Mohammadreza Shaghaghi, Sanaz Ameli, Pegah Khoshpouri, Mounes Aliyari Ghasabeh, Ahmet Gurakar, Timothy M. Pawlik, Ihab R. Kamel. Advances in Imaging of Diffuse Parenchymal Liver Disease. Journal of Clinical Gastroenterology 2020; 54(8): 682 doi: 10.1097/MCG.0000000000001380
|
13 |
L.P. Lavelle, A.C. O'Neill, C.J. McMahon, C.P. Cantwell, E.J. Heffernan, D.E. Malone, L. Daly, S.J. Skehan. Is diffusion-weighted MRI sufficient for follow-up of neuroendocrine tumour liver metastases?. Clinical Radiology 2016; 71(9): 863 doi: 10.1016/j.crad.2016.05.016
|
14 |
Stefano Palmucci, Giuseppina Cappello, Giancarlo Attinà, Giovanni Fuccio Sanzà, Pietro Valerio Foti, Giovanni Carlo Ettorre, Pietro Milone. Diffusion-Weighted MRI for the Assessment of Liver Fibrosis: Principles and Applications. BioMed Research International 2015; 2015: 1 doi: 10.1155/2015/874201
|
15 |
P. Krause, H. Flikweert, M. Monin, A. Seif Amir Hosseini, G. Helms, G. Cantanhede, B. M. Ghadimi, S. Koenig. Increased growth of colorectal liver metastasis following partial hepatectomy. Clinical & Experimental Metastasis 2013; 30(5): 681 doi: 10.1007/s10585-013-9572-y
|
16 |
Zhao-xia Yang, Xin-Xing Hu, Robert Grimm, Cai-xia Fu, Xu Yan, Meng-su Zeng, Sheng-Xiang Rao. Value of whole-liver apparent diffusion coefficient histogram analysis for quantification of liver fibrosis stages. Chinese Journal of Academic Radiology 2019; 1(1): 6 doi: 10.1007/s42058-019-00004-3
|
17 |
Mohamed Talaat Ali, Mohamed Fouad Osman, Mohamed D. Homos, Doaa Mohamed Nabil. Role of 3-T diffusion-weighted magnetic resonance imaging in differentiation between benign and malignant hepatic lesions. The Egyptian Journal of Radiology and Nuclear Medicine 2016; 47(4): 1231 doi: 10.1016/j.ejrnm.2016.08.007
|
18 |
Andrew D. Hardie, Robert E. Egbert, Michael S. Rissing. Improved differentiation between hepatic hemangioma and metastases on diffusion-weighted MRI by measurement of standard deviation of apparent diffusion coefficient. Clinical Imaging 2015; 39(4): 654 doi: 10.1016/j.clinimag.2015.04.001
|
19 |
Stefano Colagrande, Alessandro Castellani, Cosimo Nardi, Chiara Lorini, Linda Calistri, Antonella Filippone. The role of diffusion-weighted imaging in the detection of hepatic metastases from colorectal cancer: A comparison with unenhanced and Gd-EOB-DTPA enhanced MRI. European Journal of Radiology 2016; 85(5): 1027 doi: 10.1016/j.ejrad.2016.02.011
|
20 |
Tae-gun Kim, Dae-hyeon Kim, Eun-yeong Sin, Sun-yong Jin, Hyeong-ro Park, Hyeon-woo Yun, Yun-hyi Kang, Dong-ju Seo. The Usefulness of Liver Synthetic Diffusion MRI by Using Respiration Gating. Journal of the Korean Society of MR Technology 2019; 29(1): 11 doi: 10.31159/ksmrt.2019.29.1.11
|
21 |
İzzet ÖKÇESİZ, Hakan ARTAŞ, Mehmet YALNIZ. Effects of Alcohol on Liver Apparent Diffusion Coefficient values: A Single Center Study. Akademik Gastroenteroloji Dergisi 2021; 20(1): 19 doi: 10.17941/agd.927185
|