1
|
Narita M, Kawano D, Tanaka N, Naganuma T, Sasaki W, Matsumoto K, Kuinose K, Mori H, Ikeda Y, Matsumoto K, Kato R. Comparison of the characteristics between machine learning and deep learning algorithms for ablation site classification in a novel cloud-based system. Heart Rhythm 2025:S1547-5271(25)02192-7. [PMID: 40107403 DOI: 10.1016/j.hrthm.2025.03.1955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2024] [Revised: 02/24/2025] [Accepted: 03/12/2025] [Indexed: 03/22/2025]
Abstract
BACKGROUND CARTONET is a cloud-based system for the analysis of ablation procedures using the CARTO system. The current CARTONET R14 model employs deep learning, but its accuracy and positive predictive value (PPV) remain underevaluated. OBJECTIVE This study aimed to compare the characteristics of the CARTONET system between the R12.1 and the R14 models. METHODS Data from 396 atrial fibrillation ablation cases were analyzed. Using a CARTONET R14 model, the sensitivity and PPV of the automated anatomic location model were investigated. The distribution of potential reconnection sites and confidence level for each site were investigated. We also compared the difference in the data between the CARTONET R12.1, the previous CARTONET version, and the CARTONET R14 models. RESULTS We analyzed the overall tags of 39,169 points and the gap prediction of 625 segments using the CARTONET R14 model. The sensitivity and PPV of the R14 model significantly improved compared with the R12.1 model (R12.1 vs R14: sensitivity, 71.2% vs 77.5% [P < .0001]; PPV, 85.6% vs 86.2% [P = .0184]). The incidence of reconnections was highly observed in the posterior area of the right pulmonary veins (98/238 [41.2%]) and left pulmonary veins (190/387 [49.1%]). In contrast, the possibility of reconnection was highest in the roof area for the right pulmonary veins (14% [5.5%-41%]) and left pulmonary veins (16% [8%-22%]). CONCLUSION The R14 model significantly improved sensitivity and PPV compared with the R12.1 model. The tendency for predicting potential reconnection sites was similar to that of the previous version, the R12 model.
Collapse
Affiliation(s)
- Masataka Narita
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Daisuke Kawano
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Naomichi Tanaka
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Tsukasa Naganuma
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Wataru Sasaki
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Kazuhisa Matsumoto
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Kazuhiko Kuinose
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Hitoshi Mori
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan.
| | - Yoshifumi Ikeda
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Kazuo Matsumoto
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| | - Ritsushi Kato
- From the Department of Cardiology, Saitama Medical University, International Medical Center, Saitama, Japan
| |
Collapse
|
2
|
Fukaya H, Ogawa E, Mori H, Matsuura G, Toraiwa M, Ogiso S, Arakawa Y, Kobayashi S, Nakamura H, Ishizue N, Kishihara J, Oikawa J, Niwano S, Ako J. Impact of baseline-pool local impedance on lesion formation using a local impedance-sensing catheter: Lessons from a porcine experimental model. J Arrhythm 2025; 41:e70016. [PMID: 39950141 PMCID: PMC11822644 DOI: 10.1002/joa3.70016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 12/17/2024] [Accepted: 01/28/2025] [Indexed: 02/16/2025] Open
Abstract
Background Impact of baseline-pool local impedance (BP-LI) on the lesion size remains unclear. Methods Lesion size in the porcine left ventricular myocardium was evaluated using the STABLEPOINT™ catheter across various ablation settings and BP-LIs (100, 140, and 180 ohms). Results A total of 184 lesions were created with different durations (15/30/60 s) at 30 watts or with different powers (30/40/50 W) for 15 s. Lesion depth became deeper (2.8/3.0/3.6 mm at 15 s; p = .007, 4.0/4.9/4.6 mm at 30 s; p = .004, and 5.9/5.5/5.2 mm at 60 s; p = .710) and lesion width wider (5.8/6.3/7.6 mm at 15 s; p = .002, 7.0/8.9/8.9 mm at 30 s; p < .001, and 10.5/9.4/10.5 mm at 60 s; p = .262) as the BP-LI increased under 30 W. Similarly, the lesion depth became significantly deeper (2.1/3.4/3.7 mm at 30 W; p < .001, 3.5/4.6/4.6 mm at 40 W; p < .001, and 4.1/4.7/5.2 mm at 50 W; p = .002) and lesion width broader (5.1/6.9/7.0 mm at 30 W; p < .001, 7.0/7.9/8.1 mm at 40 W; p = .004, and 7.7/8.2/9.6 mm at 50 W; p < .001, respectively) as the BP-LI increased with a 15-s ablation. The relationship between the LI drop and lesion size varied with the different BP-LIs. Adjusted %LI drops (absolute LI drop divided by the BP-LI) minimized the differences between the LI values and lesion formation among the three BP-LIs. Conclusion Lesion size decreased with lower BP-LI, and the relationship between the LI drops and lesion formation varied across the different BP-LIs. Adjusted %LI drops may serve as a more reliable parameter for predicting the lesion formation.
Collapse
Affiliation(s)
- Hidehira Fukaya
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Emiyu Ogawa
- Department of Medical Engineering and TechnologyKitasato University School of Allied Health ScienceSagamiharaKanagawaJapan
| | - Hitoshi Mori
- Department of Cardiovascular MedicineSaitama Medical University International Medical CenterSaitamaJapan
| | - Gen Matsuura
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Megumi Toraiwa
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Sho Ogiso
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Yuki Arakawa
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Shuhei Kobayashi
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Hironori Nakamura
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Naruya Ishizue
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Jun Kishihara
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Jun Oikawa
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Shinichi Niwano
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| | - Junya Ako
- Department of Cardiovascular MedicineKitasato University School of MedicineSagamiharaKanagawaJapan
| |
Collapse
|
3
|
Buschmann E, Van Steenkiste G, Vernemmen I, Demeyere M, Schauvliege S, Decloedt A, van Loon G. Caudal vena cava isolation using ablation index-guided radiofrequency catheter ablation (CARTO™ 3) to treat sustained atrial tachycardia in horses. J Vet Intern Med 2025; 39:e17251. [PMID: 39614765 PMCID: PMC11638121 DOI: 10.1111/jvim.17251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2024] [Accepted: 11/05/2024] [Indexed: 12/14/2024] Open
Abstract
BACKGROUND Myocardial sleeves of the caudal vena cava are the predilection site for atrial tachycardia (AT) in horses. Caudal vena cava isolation guided by the ablation index, a lesion quality marker incorporating power, duration and contact force, might improve outcome. OBJECTIVES Describe the feasibility and outcome of caudal vena cava isolation using ablation index-guided radiofrequency catheter ablation (RFCA) to treat AT in horses. ANIMALS Ten horses with sustained AT. METHODS Records from 10 horses with sustained AT treated by three-dimensional electro-anatomical mapping and ablation index-guided RFCA (CARTO™ 3) were reviewed. RESULTS Three-dimensional electro-anatomical mapping of the right atrium identified a macro-reentry circuit in the caudomedial right atrium (n = 10). Point-by-point RFCA was performed to isolate the myocardial sleeves of the caudal vena cava in power-controlled mode with a mean of 17 ± 7 applications. The ablation index target was 400-450. A median ablation index of 436 (range, 311-763) was reached using a median maximum power of 35 (range, 24-45) W for a median duration of 20 (range, 8-45) seconds, with a median contact force of 10 (range, 3-48) g. Sinus rhythm was restored in all 10 horses. To date, 9-37 months post-ablation, none of the horses have had recurrence. CONCLUSIONS AND CLINICAL IMPORTANCE Caudal vena cava isolation using ablation index-guided RFCA was feasible and effective to permanently treat sustained AT in horses. Ablation index guidance ensured efficient lesion creation, and isolation of the caudal vena cava eliminated the arrhythmogenic substrate, thereby minimizing the risk of recurrence.
Collapse
Affiliation(s)
- Eva Buschmann
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - Glenn Van Steenkiste
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - Ingrid Vernemmen
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - Marie Demeyere
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - Stijn Schauvliege
- Department of Large Animal Surgery, Anaesthesia and OrthopaedicsGhent UniversityMerelbekeBelgium
| | - Annelies Decloedt
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| | - Gunther van Loon
- Equine Cardioteam Ghent, Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary MedicineGhent UniversityMerelbekeBelgium
| |
Collapse
|
4
|
Tzeis S, Gerstenfeld EP, Kalman J, Saad EB, Sepehri Shamloo A, Andrade JG, Barbhaiya CR, Baykaner T, Boveda S, Calkins H, Chan N, Chen M, Chen S, Dagres N, Damiano RJ, De Potter T, Deisenhofer I, Derval N, Di Biase L, Duytschaever M, Dyrda K, Hindricks G, Hocini M, Kim Y, la Meir M, Merino JL, Michaud GF, Natale A, Nault I, Nava S, Nitta T, O’Neill M, Pak H, Piccini JP, Pürerfellner H, Reichlin T, Saenz LC, Sanders P, Schilling R, Schmidt B, Supple GE, Thomas KL, Tondo C, Verma A, Wan EY. 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. J Arrhythm 2024; 40:1217-1354. [PMID: 39669937 PMCID: PMC11632303 DOI: 10.1002/joa3.13082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2024] [Accepted: 05/15/2024] [Indexed: 12/14/2024] Open
Abstract
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.
Collapse
Affiliation(s)
| | | | - Jonathan Kalman
- Department of CardiologyRoyal Melbourne HospitalMelbourneAustralia
- Department of MedicineUniversity of Melbourne and Baker Research InstituteMelbourneAustralia
| | - Eduardo B. Saad
- Electrophysiology and PacingHospital Samaritano BotafogoRio de JaneiroBrazil
- Cardiac Arrhythmia Service, Beth Israel Deaconess Medical CenterHarvard Medical SchoolBostonMAUSA
| | | | - Jason G. Andrade
- Department of MedicineVancouver General HospitalVancouverBritish ColumbiaCanada
| | | | - Tina Baykaner
- Division of Cardiology and Cardiovascular InstituteStanford UniversityStanfordCAUSA
| | - Serge Boveda
- Heart Rhythm Management DepartmentClinique PasteurToulouseFrance
- Universiteit Brussel (VUB)BrusselsBelgium
| | - Hugh Calkins
- Division of Cardiology, Department of MedicineJohns Hopkins UniversityBaltimoreMDUSA
| | - Ngai‐Yin Chan
- Department of Medicine and GeriatricsPrincess Margaret Hospital, Hong Kong Special Administrative RegionChina
| | - Minglong Chen
- The First Affiliated Hospital of Nanjing Medical UniversityNanjingChina
| | - Shih‐Ann Chen
- Heart Rhythm CenterTaipei Veterans General Hospital, Taipei, and Cardiovascular Center, Taichung Veterans General HospitalTaichungTaiwan
| | | | - Ralph J. Damiano
- Division of Cardiothoracic Surgery, Department of SurgeryWashington University School of Medicine, Barnes‐Jewish HospitalSt. LouisMOUSA
| | | | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center MunichTechnical University of Munich (TUM) School of Medicine and HealthMunichGermany
| | - Nicolas Derval
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation DepartmentFondation Bordeaux Université and Bordeaux University Hospital (CHU)Pessac‐BordeauxFrance
| | - Luigi Di Biase
- Montefiore Medical CenterAlbert Einstein College of MedicineBronxNYUSA
| | | | - Katia Dyrda
- Department of Medicine, Montreal Heart InstituteUniversité de MontréalMontrealCanada
| | | | - Meleze Hocini
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation DepartmentFondation Bordeaux Université and Bordeaux University Hospital (CHU)Pessac‐BordeauxFrance
| | - Young‐Hoon Kim
- Division of CardiologyKorea University College of Medicine and Korea University Medical CenterSeoulRepublic of Korea
| | - Mark la Meir
- Cardiac Surgery DepartmentVrije Universiteit Brussel, Universitair Ziekenhuis BrusselBrusselsBelgium
| | - Jose Luis Merino
- La Paz University Hospital, IdipazUniversidad AutonomaMadridSpain
- Hospital Viamed Santa ElenaMadridSpain
| | | | - Andrea Natale
- Texas Cardiac Arrhythmia InstituteSt. David's Medical CenterAustinTXUSA
- Case Western Reserve UniversityClevelandOHUSA
- Interventional ElectrophysiologyScripps ClinicSan DiegoCAUSA
- Department of Biomedicine and Prevention, Division of CardiologyUniversity of Tor VergataRomeItaly
| | - Isabelle Nault
- Institut Universitaire de Cardiologie et de Pneumologie de Quebec (IUCPQ)QuebecCanada
| | - Santiago Nava
- Departamento de ElectrocardiologíaInstituto Nacional de Cardiología ‘Ignacio Chávez’Ciudad de MéxicoMéxico
| | - Takashi Nitta
- Department of Cardiovascular SurgeryNippon Medical SchoolTokyoJapan
| | - Mark O’Neill
- Cardiovascular DirectorateSt. Thomas’ Hospital and King's CollegeLondonUK
| | - Hui‐Nam Pak
- Division of Cardiology, Department of Internal MedicineYonsei University College of MedicineSeoulRepublic of Korea
| | | | | | - Tobias Reichlin
- Department of Cardiology, Inselspital BernBern University Hospital, University of BernBernSwitzerland
| | - Luis Carlos Saenz
- International Arrhythmia CenterCardioinfantil FoundationBogotaColombia
| | - Prashanthan Sanders
- Centre for Heart Rhythm DisordersUniversity of Adelaide and Royal Adelaide HospitalAdelaideAustralia
| | | | - Boris Schmidt
- Cardioangiologisches Centrum BethanienMedizinische Klinik III, Agaplesion MarkuskrankenhausFrankfurtGermany
| | - Gregory E. Supple
- Cardiac Electrophysiology SectionUniversity of Pennsylvania Perelman School of MedicinePhiladelphiaPAUSA
| | | | - Claudio Tondo
- Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico MonzinoIRCCSMilanItaly
- Department of Biomedical, Surgical and Dental SciencesUniversity of MilanMilanItaly
| | - Atul Verma
- McGill University Health CentreMcGill UniversityMontrealCanada
| | - Elaine Y. Wan
- Department of Medicine, Division of CardiologyColumbia University Vagelos College of Physicians and SurgeonsNew YorkNYUSA
| |
Collapse
|
5
|
Buschmann E, Van Steenkiste G, Duytschaever M, Segers P, Ibrahim L, van Loon G, Decloedt A. In vitro characterization of radiofrequency ablation lesions in equine and swine myocardial tissue. Sci Rep 2024; 14:22877. [PMID: 39358479 PMCID: PMC11447003 DOI: 10.1038/s41598-024-74486-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2024] [Accepted: 09/26/2024] [Indexed: 10/04/2024] Open
Abstract
Radiofrequency ablation is a promising technique for arrhythmia treatment in horses. Due to the thicker myocardial wall and higher blood flow in horses, it is unknown if conventional radiofrequency settings used in human medicine can be extrapolated to horses. The study aim is to describe the effect of ablation settings on lesion dimensions in equine myocardium. To study species dependent effects, results were compared to swine myocardium. Right ventricular and right and left atrial equine myocardium and right ventricular swine myocardium were suspended in a bath with circulating isotonic saline at 37 °C. The ablation catheter delivered radiofrequency energy at different-power-duration combinations with a contact force of 20 g. Lesion depth and width were measured and lesion volume was calculated. Higher power or longer duration of radiofrequency energy delivery increased lesion size significantly in the equine atrial myocardium and in equine and swine ventricular myocardium (P < 0.001). Mean lesion depth in equine atrial myocardium ranged from 2.9 to 5.5 mm with a diameter ranging from 6.9 to 10.1 mm. Lesion diameter was significantly larger in equine tissue compared to swine tissue (P = 0.020). Obtained data in combination with estimated wall thickness can improve lesion transmurality which might reduce arrhythmia recurrence. Optimal ablation settings may differ between species.
Collapse
Affiliation(s)
- Eva Buschmann
- Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Equine Cardioteam Ghent University, Ghent University, Merelbeke, Belgium.
| | - Glenn Van Steenkiste
- Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Equine Cardioteam Ghent University, Ghent University, Merelbeke, Belgium
| | | | - Patrick Segers
- Institute of Biomedical Engineering and Technology, Faculty of Engineering and Architecture, Ghent University, Ghent, Belgium
| | - Lara Ibrahim
- Department of Morphology, Imaging, Orthopedics, Rehabilitation and Nutrition, Ghent University, Merelbeke, Belgium
| | - Gunther van Loon
- Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Equine Cardioteam Ghent University, Ghent University, Merelbeke, Belgium
| | - Annelies Decloedt
- Department of Internal Medicine, Reproduction and Population Medicine, Faculty of Veterinary Medicine, Equine Cardioteam Ghent University, Ghent University, Merelbeke, Belgium
| |
Collapse
|
6
|
Tzeis S, Gerstenfeld EP, Kalman J, Saad EB, Shamloo AS, Andrade JG, Barbhaiya CR, Baykaner T, Boveda S, Calkins H, Chan NY, Chen M, Chen SA, Dagres N, Damiano RJ, De Potter T, Deisenhofer I, Derval N, Di Biase L, Duytschaever M, Dyrda K, Hindricks G, Hocini M, Kim YH, la Meir M, Merino JL, Michaud GF, Natale A, Nault I, Nava S, Nitta T, O'Neill M, Pak HN, Piccini JP, Pürerfellner H, Reichlin T, Saenz LC, Sanders P, Schilling R, Schmidt B, Supple GE, Thomas KL, Tondo C, Verma A, Wan EY. 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 2024; 21:e31-e149. [PMID: 38597857 DOI: 10.1016/j.hrthm.2024.03.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Accepted: 03/11/2024] [Indexed: 04/11/2024]
Abstract
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.
Collapse
Affiliation(s)
- Stylianos Tzeis
- Department of Cardiology, Mitera Hospital, 6, Erythrou Stavrou Str., Marousi, Athens, PC 151 23, Greece.
| | - Edward P Gerstenfeld
- Section of Cardiac Electrophysiology, University of California, San Francisco, CA, USA
| | - Jonathan Kalman
- Department of Cardiology, Royal Melbourne Hospital, Melbourne, Australia; Department of Medicine, University of Melbourne and Baker Research Institute, Melbourne, Australia
| | - Eduardo B Saad
- Electrophysiology and Pacing, Hospital Samaritano Botafogo, Rio de Janeiro, Brazil; Cardiac Arrhythmia Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | - Jason G Andrade
- Department of Medicine, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | | | - Tina Baykaner
- Division of Cardiology and Cardiovascular Institute, Stanford University, Stanford, CA, USA
| | - Serge Boveda
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France; Universiteit Brussel (VUB), Brussels, Belgium
| | - Hugh Calkins
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Ngai-Yin Chan
- Department of Medicine and Geriatrics, Princess Margaret Hospital, Hong Kong Special Administrative Region, China
| | - Minglong Chen
- The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Shih-Ann Chen
- Heart Rhythm Center, Taipei Veterans General Hospital, Taipei, and Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan
| | | | - Ralph J Damiano
- Division of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, MO, USA
| | | | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM) School of Medicine and Health, Munich, Germany
| | - Nicolas Derval
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation Department, Fondation Bordeaux Université and Bordeaux University Hospital (CHU), Pessac-Bordeaux, France
| | - Luigi Di Biase
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | | | - Katia Dyrda
- Department of Medicine, Montreal Heart Institute, Université de Montréal, Montreal, Canada
| | | | - Meleze Hocini
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation Department, Fondation Bordeaux Université and Bordeaux University Hospital (CHU), Pessac-Bordeaux, France
| | - Young-Hoon Kim
- Division of Cardiology, Korea University College of Medicine and Korea University Medical Center, Seoul, Republic of Korea
| | - Mark la Meir
- Cardiac Surgery Department, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium
| | - Jose Luis Merino
- La Paz University Hospital, Idipaz, Universidad Autonoma, Madrid, Spain; Hospital Viamed Santa Elena, Madrid, Spain
| | | | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA; Case Western Reserve University, Cleveland, OH, USA; Interventional Electrophysiology, Scripps Clinic, San Diego, CA, USA; Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy
| | - Isabelle Nault
- Institut Universitaire de Cardiologie et de Pneumologie de Quebec (IUCPQ), Quebec, Canada
| | - Santiago Nava
- Departamento de Electrocardiología, Instituto Nacional de Cardiología 'Ignacio Chávez', Ciudad de México, México
| | - Takashi Nitta
- Department of Cardiovascular Surgery, Nippon Medical School, Tokyo, Japan
| | - Mark O'Neill
- Cardiovascular Directorate, St. Thomas' Hospital and King's College, London, UK
| | - Hui-Nam Pak
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | | | | | - Tobias Reichlin
- Department of Cardiology, Inselspital Bern, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Luis Carlos Saenz
- International Arrhythmia Center, Cardioinfantil Foundation, Bogota, Colombia
| | - Prashanthan Sanders
- Centre for Heart Rhythm Disorders, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
| | | | - Boris Schmidt
- Cardioangiologisches Centrum Bethanien, Medizinische Klinik III, Agaplesion Markuskrankenhaus, Frankfurt, Germany
| | - Gregory E Supple
- Cardiac Electrophysiology Section, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA
| | | | - Claudio Tondo
- Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Atul Verma
- McGill University Health Centre, McGill University, Montreal, Canada
| | - Elaine Y Wan
- Department of Medicine, Division of Cardiology, Columbia University Vagelos College of Physicians and Surgeons, New York, NY, USA
| |
Collapse
|
7
|
Tzeis S, Gerstenfeld EP, Kalman J, Saad E, Shamloo AS, Andrade JG, Barbhaiya CR, Baykaner T, Boveda S, Calkins H, Chan NY, Chen M, Chen SA, Dagres N, Damiano RJ, De Potter T, Deisenhofer I, Derval N, Di Biase L, Duytschaever M, Dyrda K, Hindricks G, Hocini M, Kim YH, la Meir M, Merino JL, Michaud GF, Natale A, Nault I, Nava S, Nitta T, O'Neill M, Pak HN, Piccini JP, Pürerfellner H, Reichlin T, Saenz LC, Sanders P, Schilling R, Schmidt B, Supple GE, Thomas KL, Tondo C, Verma A, Wan EY. 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. J Interv Card Electrophysiol 2024; 67:921-1072. [PMID: 38609733 DOI: 10.1007/s10840-024-01771-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/14/2024]
Abstract
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.
Collapse
Affiliation(s)
| | - Edward P Gerstenfeld
- Section of Cardiac Electrophysiology, University of California, San Francisco, CA, USA
| | - Jonathan Kalman
- Department of Cardiology, Royal Melbourne Hospital, Melbourne, Australia
- Department of Medicine, University of Melbourne and Baker Research Institute, Melbourne, Australia
| | - Eduardo Saad
- Electrophysiology and Pacing, Hospital Samaritano Botafogo, Rio de Janeiro, Brazil
- Cardiac Arrhythmia Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | - Jason G Andrade
- Department of Medicine, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | | | - Tina Baykaner
- Division of Cardiology and Cardiovascular Institute, Stanford University, Stanford, CA, USA
| | - Serge Boveda
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France
- Universiteit Brussel (VUB), Brussels, Belgium
| | - Hugh Calkins
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Ngai-Yin Chan
- Department of Medicine and Geriatrics, Princess Margaret Hospital, Hong Kong Special Administrative Region, China
| | - Minglong Chen
- The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Shih-Ann Chen
- Heart Rhythm Center, Taipei Veterans General Hospital, Taipei, Taiwan
| | - Nikolaos Dagres
- Department of Cardiac Electrophysiology, Charité University Berlin, Berlin, Germany
| | - Ralph J Damiano
- Division of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, MO, USA
| | | | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM) School of Medicine and Health, Munich, Germany
| | - Nicolas Derval
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation Department, Fondation Bordeaux Université and Bordeaux University Hospital (CHU), Pessac-Bordeaux, France
| | - Luigi Di Biase
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | | | - Katia Dyrda
- Department of Cardiology, Montreal Heart Institute, Université de Montréal, Montreal, Canada
| | - Gerhard Hindricks
- Department of Cardiac Electrophysiology, Charité University Berlin, Berlin, Germany
| | - Meleze Hocini
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation Department, Fondation Bordeaux Université and Bordeaux University Hospital (CHU), Pessac-Bordeaux, France
| | - Young-Hoon Kim
- Division of Cardiology, Korea University College of Medicine and Korea University Medical Center, Seoul, Republic of Korea
| | - Mark la Meir
- Cardiac Surgery Department, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, Brussels, Belgium
| | - Jose Luis Merino
- La Paz University Hospital, Idipaz, Universidad Autonoma, Madrid, Spain
- Hospital Viamed Santa Elena, Madrid, Spain
| | - Gregory F Michaud
- Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center, Austin, TX, USA
- Case Western Reserve University, Cleveland, OH, USA
- Interventional Electrophysiology, Scripps Clinic, San Diego, CA, USA
- Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy
| | - Isabelle Nault
- Institut Universitaire de Cardiologie et de Pneumologie de Quebec (IUCPQ), Quebec, Canada
| | - Santiago Nava
- Departamento de Electrocardiología, Instituto Nacional de Cardiología 'Ignacio Chávez', Ciudad de México, México
| | - Takashi Nitta
- Department of Cardiovascular Surgery, Nippon Medical School, Tokyo, Japan
| | - Mark O'Neill
- Cardiovascular Directorate, St. Thomas' Hospital and King's College, London, UK
| | - Hui-Nam Pak
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | | | | | - Tobias Reichlin
- Department of Cardiology, Inselspital Bern, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Luis Carlos Saenz
- International Arrhythmia Center, Cardioinfantil Foundation, Bogota, Colombia
| | - Prashanthan Sanders
- Centre for Heart Rhythm Disorders, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
| | | | - Boris Schmidt
- Cardioangiologisches Centrum Bethanien, Medizinische Klinik III, Agaplesion Markuskrankenhaus, Frankfurt, Germany
| | - Gregory E Supple
- Cardiac Electrophysiology Section, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA
| | | | - Claudio Tondo
- Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Atul Verma
- McGill University Health Centre, McGill University, Montreal, Canada
| | - Elaine Y Wan
- Department of Medicine, Division of Cardiology, Columbia University Vagelos College of Physicians and Surgeons, New York, NY, USA
| |
Collapse
|
8
|
Galuszka OM, Baldinger SH, Servatius H, Seiler J, Madaffari A, Kozhuharov N, Thalmann G, Kueffer T, Muehl A, Maurhofer J, Haeberlin A, Noti F, Tanner H, Reichlin T, Roten L. Durability of CLOSE-Guided Pulmonary Vein Isolation in Persistent Atrial Fibrillation: A Prospective Remapping Study. JACC Clin Electrophysiol 2024; 10:1090-1100. [PMID: 38639700 DOI: 10.1016/j.jacep.2024.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 02/20/2024] [Accepted: 02/27/2024] [Indexed: 04/20/2024]
Abstract
BACKGROUND Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF. OBJECTIVES The purpose of this study was to evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI. METHODS In a prospective study, we included patients with symptomatic, persistent AF undergoing CLOSE-guided radiofrequency ablation. Irrespective of AF recurrence, a redo procedure was mandated 6 months following the index procedure to evaluate PV reconnections. The outcome of AF ablation was based on clinical recurrence and 7-day Holter electrocardiogram 3 and 6 months after the index procedure and 3, 6, and 12 months after the redo procedure. RESULTS Of 30 patients included, 26 (81% men; median age 68 years) underwent the planned remapping study a median of 6 months after the index procedure, whereas 4 patients without recurrence refused a repeat procedure. In total, 78 of 102 (76%) PVs showed durable isolation and 15 patients (58%) presented complete isolation of all PVs. Beyond the blanking period, 6 of 26 patients (23%) had arrhythmia recurrence before the redo procedure. Recurrence had occurred in 33% of patients with complete isolation of all veins and in 9% of patients with PV reconnections (P = 0.197). After re-PVI in patients with PV reconnections and additional ablation in patients with recurrence but durable PVI, 17 of 26 patients (65%) were free of arrhythmia after 12 months. CONCLUSIONS In patients with persistent AF, CLOSE-guided PVI resulted in durable rate of PVI on a per-vein and per-patient level of 76% and 58%, respectively. Arrhythmia recurrence was numerically higher in patients with durable PVI compared with patients without.
Collapse
Affiliation(s)
- Oskar M Galuszka
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Samuel H Baldinger
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Helge Servatius
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jens Seiler
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Antonio Madaffari
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Nikola Kozhuharov
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Gregor Thalmann
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Thomas Kueffer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Aline Muehl
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Jens Maurhofer
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Andreas Haeberlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | - Fabian Noti
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Hildegard Tanner
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Tobias Reichlin
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Laurent Roten
- Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
| |
Collapse
|
9
|
Brahier MS, Piccini JP. Pulmonary Vein Isolation in Persistent Atrial Fibrillation: Not Necessarily Durable, Nor Sufficient. JACC Clin Electrophysiol 2024; 10:1101-1103. [PMID: 38925720 DOI: 10.1016/j.jacep.2024.05.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 05/08/2024] [Accepted: 05/08/2024] [Indexed: 06/28/2024]
Affiliation(s)
- Mark S Brahier
- Electrophysiology Section, Duke Heart Center, Duke University Hospital and Duke Clinical Research Institute, Durham, North Carolina, USA
| | - Jonathan P Piccini
- Electrophysiology Section, Duke Heart Center, Duke University Hospital and Duke Clinical Research Institute, Durham, North Carolina, USA.
| |
Collapse
|
10
|
Tzeis S, Gerstenfeld EP, Kalman J, Saad EB, Sepehri Shamloo A, Andrade JG, Barbhaiya CR, Baykaner T, Boveda S, Calkins H, Chan NY, Chen M, Chen SA, Dagres N, Damiano RJ, De Potter T, Deisenhofer I, Derval N, Di Biase L, Duytschaever M, Dyrda K, Hindricks G, Hocini M, Kim YH, la Meir M, Merino JL, Michaud GF, Natale A, Nault I, Nava S, Nitta T, O’Neill M, Pak HN, Piccini JP, Pürerfellner H, Reichlin T, Saenz LC, Sanders P, Schilling R, Schmidt B, Supple GE, Thomas KL, Tondo C, Verma A, Wan EY. 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace 2024; 26:euae043. [PMID: 38587017 PMCID: PMC11000153 DOI: 10.1093/europace/euae043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 01/16/2024] [Indexed: 04/09/2024] Open
Abstract
In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .
Collapse
Affiliation(s)
- Stylianos Tzeis
- Department of Cardiology, Mitera Hospital, 6, Erythrou Stavrou Str., Marousi, Athens, PC 151 23, Greece
| | - Edward P Gerstenfeld
- Section of Cardiac Electrophysiology, University of California, San Francisco, CA, USA
| | - Jonathan Kalman
- Department of Cardiology, Royal Melbourne Hospital, Melbourne, Australia
- Department of Medicine, University of Melbourne and Baker Research Institute, Melbourne, Australia
| | - Eduardo B Saad
- Electrophysiology and Pacing, Hospital Samaritano Botafogo, Rio de Janeiro, Brazil
- Cardiac Arrhythmia Service, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | | | - Jason G Andrade
- Department of Medicine, Vancouver General Hospital, Vancouver, British Columbia, Canada
| | | | - Tina Baykaner
- Division of Cardiology and Cardiovascular Institute, Stanford University, Stanford, CA, USA
| | - Serge Boveda
- Heart Rhythm Management Department, Clinique Pasteur, Toulouse, France
- Universiteit Brussel (VUB), Brussels, Belgium
| | - Hugh Calkins
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Ngai-Yin Chan
- Department of Medicine and Geriatrics, Princess Margaret Hospital, Hong Kong Special Administrative Region, China
| | - Minglong Chen
- The First Affiliated Hospital of Nanjing Medical University, Nanjing, China
| | - Shih-Ann Chen
- Heart Rhythm Center, Taipei Veterans General Hospital, Taipei, and Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan
| | | | - Ralph J Damiano
- Division of Cardiothoracic Surgery, Department of Surgery, Washington University School of Medicine, Barnes-Jewish Hospital, St. Louis, MO, USA
| | | | - Isabel Deisenhofer
- Department of Electrophysiology, German Heart Center Munich, Technical University of Munich (TUM) School of Medicine and Health, Munich, Germany
| | - Nicolas Derval
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation Department, Fondation Bordeaux Université and Bordeaux University Hospital (CHU), Pessac-Bordeaux, France
| | - Luigi Di Biase
- Montefiore Medical Center, Albert Einstein College of Medicine, Bronx, NY, USA
| | | | - Katia Dyrda
- Department of Medicine, Montreal Heart Institute, Université de Montréal, Montreal, Canada
| | | | - Meleze Hocini
- IHU LIRYC, Electrophysiology and Heart Modeling Institute, Cardiac Electrophysiology and Stimulation Department, Fondation Bordeaux Université and Bordeaux University Hospital (CHU), Pessac-Bordeaux, France
| | - Young-Hoon Kim
- Division of Cardiology, Korea University College of Medicine and Korea University Medical Center, Seoul, Republic of Korea
| | - Mark la Meir
- Cardiac Surgery Department, Vrije Universiteit Brussel, Universitair Ziekenhuis Brussel, Brussels, Belgium
| | - Jose Luis Merino
- La Paz University Hospital, Idipaz, Universidad Autonoma, Madrid, Spain
- Hospital Viamed Santa Elena, Madrid, Spain
| | | | - Andrea Natale
- Texas Cardiac Arrhythmia Institute, St. David’s Medical Center, Austin, TX, USA
- Case Western Reserve University, Cleveland, OH, USA
- Interventional Electrophysiology, Scripps Clinic, San Diego, CA, USA
- Department of Biomedicine and Prevention, Division of Cardiology, University of Tor Vergata, Rome, Italy
| | - Isabelle Nault
- Institut Universitaire de Cardiologie et de Pneumologie de Quebec (IUCPQ), Quebec, Canada
| | - Santiago Nava
- Departamento de Electrocardiología, Instituto Nacional de Cardiología ‘Ignacio Chávez’, Ciudad de México, México
| | - Takashi Nitta
- Department of Cardiovascular Surgery, Nippon Medical School, Tokyo, Japan
| | - Mark O’Neill
- Cardiovascular Directorate, St. Thomas’ Hospital and King’s College, London, UK
| | - Hui-Nam Pak
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | | | | | - Tobias Reichlin
- Department of Cardiology, Inselspital Bern, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Luis Carlos Saenz
- International Arrhythmia Center, Cardioinfantil Foundation, Bogota, Colombia
| | - Prashanthan Sanders
- Centre for Heart Rhythm Disorders, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
| | | | - Boris Schmidt
- Cardioangiologisches Centrum Bethanien, Medizinische Klinik III, Agaplesion Markuskrankenhaus, Frankfurt, Germany
| | - Gregory E Supple
- Cardiac Electrophysiology Section, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA, USA
| | | | - Claudio Tondo
- Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy
| | - Atul Verma
- McGill University Health Centre, McGill University, Montreal, Canada
| | - Elaine Y Wan
- Department of Medicine, Division of Cardiology, Columbia University Vagelos College of Physicians and Surgeons, New York, NY, USA
| |
Collapse
|
11
|
Boga M, Orbán G, Perge P, Salló Z, Tanai E, Ferencz AB, Tóth P, Komlósi F, Osztheimer I, Nagy KV, Merkely B, Gellér L, Szegedi N. Adherence to the CLOSE Protocol and Low Baseline Generator Impedance Are Independent Predictors of Durable Pulmonary Vein Isolation. J Clin Med 2024; 13:1960. [PMID: 38610727 PMCID: PMC11012634 DOI: 10.3390/jcm13071960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2024] [Revised: 03/24/2024] [Accepted: 03/26/2024] [Indexed: 04/14/2024] Open
Abstract
Background: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is predominantly attributed to pulmonary vein reconnection (PVR). Predictors of AF recurrence have been widely studied; however, data are scarce on procedural parameters that predict chronic PVR. We aimed to study PVR rates and predictors of PVR. Methods: We retrospectively included 100 patients who underwent repeated ablation due to AF recurrence after initial PVI with the CARTO system. PVR was determined during the repeated procedure by electrophysiological evaluation, and initial procedural characteristics predicting PVR were studied, including adherence to the CLOSE protocol, use of high power, first-pass isolation (FPI), and baseline generator impedance (BGI). Results: Thirty-eight patients underwent initial CLOSE-guided PVI, and sixty-two underwent initial non-CLOSE PVI. A repeat procedure was performed 23 ± 16 months after the initial procedure. In total, PVR was found in 192 of 373 PVs (51.5%), and all PVs were isolated in 17/100 (17%) patients. Factors associated with all PVs being isolated were adherence to the CLOSE protocol, a higher power setting, the presence of bilateral FPI, and lower BGI (88% vs. 28%, p < 0.0001; 37.5 W vs. 30 W, p = 0.0276; 88.2% vs. 40.4%, p = 0.0007; and 127.6 Ω vs. 136.6 Ω, p = 0.0027, respectively). In initial procedures with adherence to the CLOSE protocol, the FPI rate was significantly higher (73.7% vs. 25%, p < 0.0001), while there were no significant differences in terms of procedure time and left atrial dwell time (81 vs. 85 min, p = 0.83; and 60 vs. 58 min, p = 0.08, respectively). BGI ≥ 130 Ω (AUC = 0.7403, sensitivity: 77.1%, specificity: 68.8%, p = 0.0032) was associated with a significantly higher probability of PVR (OR = 6.757; p < 0.0001). In multivariable analysis, independent predictors for PVR were non-adherence to the CLOSE protocol and BGI ≥ 130 Ω. Conclusions: Our findings indicate that adherence to the CLOSE protocol and baseline generator impedance < 130 Ω during AF ablation are independent predictors of PVI durability.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | | | | | - Nándor Szegedi
- Heart and Vascular Center, Semmelweis University, 1085 Budapest, Hungary; (M.B.); (G.O.)
| |
Collapse
|
12
|
Jin Z, Hwang T, Kim D, Lim B, Kwon OS, Kim S, Kim MH, Park JW, Yu HT, Kim TH, Uhm JS, Joung B, Lee MH, Pak HN. Anti- and pro-fibrillatory effects of pulmonary vein isolation gaps in human atrial fibrillation digital twins. NPJ Digit Med 2024; 7:81. [PMID: 38532181 DOI: 10.1038/s41746-024-01075-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 03/07/2024] [Indexed: 03/28/2024] Open
Abstract
Although pulmonary vein isolation (PVI) gaps and extrapulmonary vein triggers contribute to recurrence after atrial fibrillation (AF) ablation, their precise mechanisms remain unproven. Our study assessed the impact of PVI gaps on rhythm outcomes using a human AF digital twin. We included 50 patients (76.0% with persistent AF) who underwent catheter ablation with a realistic AF digital twin by integrating computed tomography and electroanatomical mapping. We evaluated the final rhythm status, including AF and atrial tachycardia (AT), across 600 AF episodes, considering factors including PVI level, PVI gap number, and pacing locations. Our findings revealed that antral PVI had a significantly lower ratio of AF at the final rhythm (28% vs. 56%, p = 0.002) than ostial PVI. Increasing PVI gap numbers correlated with an increased ratio of AF at the final rhythm (p < 0.001). Extra-PV induction yielded a higher ratio of AF at the final rhythm than internal PV induction (77.5% vs. 59.0%, p < 0.001). In conclusion, our human AF digital twin model helped assess AF maintenance mechanisms. Clinical trial registration: https://www.clinicaltrials.gov ; Unique identifier: NCT02138695.
Collapse
Affiliation(s)
- Ze Jin
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Taehyun Hwang
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Daehoon Kim
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Byounghyun Lim
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Oh-Seok Kwon
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Sangbin Kim
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Moon-Hyun Kim
- Division of Cardiology, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea
| | - Je-Wook Park
- Division of Cardiology, Department of Internal Medicine, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea
| | - Hee Tae Yu
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Tae-Hoon Kim
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Jae-Sun Uhm
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Boyoung Joung
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Moon-Hyoung Lee
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Hui-Nam Pak
- Division of Cardiology, Department of Internal Medicine, Yonsei University College of Medicine, Seoul, Republic of Korea.
| |
Collapse
|
13
|
Narita M, Higuchi S, Kawano D, Sasaki W, Matsumoto K, Tanaka N, Mori H, Tsutsui K, Ikeda Y, Arai T, Nakano S, Kato R, Matsumoto K. Does the same lesion index mean the same efficacy and safety profile: influence of the differential power, time, and contact force on the lesion size and steam pops under the same lesion index. J Interv Card Electrophysiol 2024; 67:147-155. [PMID: 37311981 DOI: 10.1007/s10840-023-01583-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 05/28/2023] [Indexed: 06/15/2023]
Abstract
BACKGROUND The lesion index (LSI) helps predict the lesion size and is widely used in ablation of various types of arrhythmias. However, the influence of the ablation settings on the lesion formation and incidence of steam pops under the same LSI value remains unclear. METHODS Using a contact force (CF) sensing catheter (TactiCath™) in an ex vivo swine left ventricle model, RF lesions were created with a combination of various power steps (30 W, 40 W, 50 W) and CFs (10 g, 20 g, 30 g, 40 g, 50 g) under the same LSI values (5.2 and 7.0). The correlation between the lesion formation and ablation parameters was evaluated. RESULTS Ninety RF lesions were created under a target LSI value of 5.2, and eighty-four were developed under a target LSI value of 7.0. In the LSI 5.2 group, the resultant lesion size widely varied according to the ablation power, and a multiple regression analysis indicated that the ablation energy delivered was the best predictor of the lesion formation. To create a lesion depth > 4 mm, an ablation energy of 393 J is the best cutoff value, suggesting a possibility that ablation energy may be used as a supplemental marker that better monitors the progress of the lesion formation in an LSI 5.2 ablation. In contrast, such inconsistency was not obvious in the LSI 7.0 group. Compared with 30 W, the 50-W ablation exhibited a higher incidence of steam pops in both the LSI 5.2 and 7.0 groups. CONCLUSIONS The LSI-lesion size relationship was not necessarily consistent, especially for an LSI of 5.2. To avoid any unintentional, weak ablation, the ablation energy may be a useful supportive parameter (393 J as a cutoff value for a 4-mm depth) during ablation with an LSI around 5.2. Thanks to a prolonged ablation time, the LSI-lesion size relationship is consistent for an LSI of 7.0. However, it is accompanied by a high incidence of steam pops. Care should be given to the ablation settings even when the same LSI value is used.
Collapse
Affiliation(s)
- Masataka Narita
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Syunta Higuchi
- Department of Medical Engineer, Saitama Medical University International Medical Center, Hidaka, Japan
| | - Daisuke Kawano
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Wataru Sasaki
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Kazuhisa Matsumoto
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Naomichi Tanaka
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Hitoshi Mori
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan.
| | - Kenta Tsutsui
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Yoshifumi Ikeda
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Takahide Arai
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Shintaro Nakano
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Ritsushi Kato
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| | - Kazuo Matsumoto
- Department of Cardiology, Saitama Medical University International Medical Center, Yamane, Hidaka, Saitama, 1397-1, Japan
| |
Collapse
|
14
|
Serban T, Mannhart D, Abid QUA, Höchli A, Lazar S, Krisai P, Bettelini AS, Knecht S, Kühne M, Sticherling C, du Fay de Lavallaz J, Badertscher P. Durability of pulmonary vein isolation for atrial fibrillation: a meta-analysis and systematic review. Europace 2023; 25:euad335. [PMID: 37944133 PMCID: PMC10664405 DOI: 10.1093/europace/euad335] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/05/2023] [Accepted: 10/30/2023] [Indexed: 11/12/2023] Open
Abstract
AIMS Pulmonary vein isolation (PVI) plays a central role in the interventional treatment of atrial fibrillation (AF). Uncertainties remain about the durability of ablation lesions from different energy sources. We aimed to systematically review the durability of ablation lesions associated with various PVI-techniques using different energy sources for the treatment of AF. METHODS AND RESULTS Structured systematic database search for articles published between January 2010 and January 2023 reporting PVI-lesion durability as evaluated in the overall cohort through repeat invasive remapping during follow-up. Studies evaluating only a proportion of the initial cohort in redo procedures were excluded. A total of 19 studies investigating 1050 patients (mean age 60 years, 31% women, time to remap 2-7 months) were included. In a pooled analysis, 99.7% of the PVs and 99.4% of patients were successfully ablated at baseline and 75.5% of the PVs remained isolated and 51% of the patients had all PVs persistently isolated at follow-up across all energy sources. In a pooled analysis of the percentages of PVs durably isolated during follow-up, the estimates of RFA were the lowest of all energy sources at 71% (95% CI 69-73, 11 studies), but comparable with cryoballoon (79%, 95%CI 74-83, 3 studies). Higher durability percentages were reported in PVs ablated with laser-balloon (84%, 95%CI 78-89, one study) and PFA (87%, 95%CI 84-90, 2 studies). CONCLUSION We observed no significant difference in the durability of the ablation lesions of the four evaluated energies after adjusting for procedural and baseline populational characteristics.
Collapse
Affiliation(s)
- Teodor Serban
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Diego Mannhart
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | | | - Andres Höchli
- Department of Cardiology, Triemli Stadtspital, Zürich, Switzerland
| | - Sorin Lazar
- Department of Cardiology, Cook County Health, Chicago, IL, USA
| | - Philipp Krisai
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Arianna Sofia Bettelini
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Sven Knecht
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Michael Kühne
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Christian Sticherling
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Jeanne du Fay de Lavallaz
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| | - Patrick Badertscher
- Department of Cardiology, University Hospital of Basel, Petersgraben 4, 4031 Basel, Switzerland
- Cardiovascular Research Institute Basel, Spitalstrasse 2, 4056 Basel, Switzerland
| |
Collapse
|
15
|
Dzhinsov KR. Methods and techniques for increasing the safety and efficacy of pulmonary vein isolation in patients with atrial fibrillation. Folia Med (Plovdiv) 2023; 65:713-719. [PMID: 38351752 DOI: 10.3897/folmed.65.e103031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Accepted: 07/16/2023] [Indexed: 02/16/2024] Open
Abstract
The most common type of sustained arrhythmia is atrial fibrillation (AF). Pulmonary vein isolation (PVI) is the cornerstone of catheter ablation for atrial fibrillation, which has emerged as the primary therapeutic strategy for atrial fibrillation patients. Unfortunately, about one-third of patients experience recurrent atrial arrhythmias after the procedure.
Collapse
|
16
|
Jin X, Zhou Y, Wu Y, Xie M. Safety and efficacy of steerable versus non-steerable sheaths for catheter ablation of atrial fibrillation systematic review and meta-analysis. BMJ Open 2023; 13:e068350. [PMID: 37734901 PMCID: PMC10514598 DOI: 10.1136/bmjopen-2022-068350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Accepted: 09/08/2023] [Indexed: 09/23/2023] Open
Abstract
OBJECTIVES With the development of radiofrequency (RF) ablation technology. In recent years, more and more patients with atrial fibrillation (AF) have been treated with RF ablation. Steerable sheaths (SS) have been widely used in RF ablation of AF. The aim of this meta-analysis was to compare the efficacy and safety of AF ablation using SS and non-steerable sheaths (NSS). METHODS From the beginning to March 2022, we conducted a comprehensive, systematic search of the databases PubMed, MEDLINE, EMBASE, Web of Science and the Cochrane Library to finish the study. For categorical and continuous data, we used ORs and mean difference to calculate the effect. We also estimated the 95% CI. RESULTS Five studies of RF ablation of AF were selected, three prospective and two retrospective, involving 282 SS and 236 NSS ablation patients. The rate of recurrence of AF or atrial arrhythmias was 27.3% versus 42.8% (OR: 0.52, 95% CI 0.36, 0.76, z=3.41, p=0.0006) and acute pulmonary vein (PV) reconnection (8.7% vs 17.4%, OR: 0.47, 95% CI 0.23, 0.95, z=2.10, p=0.04). In the SS group and the NSS group, the total ablation time (p=0.25), fluoroscopy time (p=0.26) and total operative time (p=0.35) were not significantly different. CONCLUSIONS Compared with the use of NSS, the use of SS for RF ablation of AF can effectively reduce the recurrence rate of AF and the occurrence of acute PVs reconnection events. However, there is no advantage in shortening the total RF time, fluoroscopy time, total surgical time and reducing complications.
Collapse
Affiliation(s)
- Xinyao Jin
- Department of Cardiology, Hangzhou Red Cross Hospital, Hangzhou, China
| | - Yuqing Zhou
- First Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, China
| | - Yuanhong Wu
- Department of Cardiology, Hangzhou Red Cross Hospital, Hangzhou, China
| | - Mingbin Xie
- Department of Cardiology, Hangzhou Red Cross Hospital, Hangzhou, China
| |
Collapse
|
17
|
Okumura K, Inoue K, Goya M, Origasa H, Yamazaki M, Nogami A. Acute and mid-term outcomes of ablation for atrial fibrillation with VISITAG SURPOINT: the Japan MIYABI registry. Europace 2023; 25:euad221. [PMID: 37490850 PMCID: PMC10492225 DOI: 10.1093/europace/euad221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Accepted: 07/10/2023] [Indexed: 07/27/2023] Open
Abstract
AIMS The effectiveness of pulmonary vein isolation (PVI) guided by VISITAG SURPOINT (VS) has been demonstrated in Western populations. However, data for Asian populations are limited. VS settings may differ for Asians, given their smaller body size. This study aimed to describe outcomes of radiofrequency atrial fibrillation (AF) ablation guided by VS in a large Asian population. METHODS AND RESULTS The prospective, observational, multicentre MIYABI registry collected real-world data from patients undergoing VS-guided AF ablation using ThermoCool SmartTouch and ThermoCool SmartTouch SF catheters from 50 Japanese centres. All patients had paroxysmal AF or persistent AF for <6 months. Primary adverse events (PAEs) were evaluated for safety. The primary efficacy endpoint was the proportion of patients with PVI at the end of the procedure. Mid-term effectiveness (up to 12 months) was evaluated by freedom from documented atrial arrhythmias. Of the 1011 patients enrolled, 1002 completed AF ablation. The mean number of VS values per procedure was 428.8 on the anterior wall and 400.4 on the posterior wall. Nine patients (0.9%) experienced PAEs. Upon procedure completion, 99.7% of patients had PVI. Twelve-month freedom from atrial arrhythmia recurrence was 88.5%; 5.7% of patients were re-ablated. At repeat ablation, 54% of RSPV, 73% of RIPV, 70% of LSPV, and 86% of LIPV evaluated remained durably isolated. CONCLUSION Despite lower anterior wall VS values compared with the CLOSE protocol (≥550), the present study demonstrated comparable efficacy outcomes, indicating that a VS of ≥550 for the anterior wall may not be necessary for Asian patients.
Collapse
Affiliation(s)
- Ken Okumura
- Division of Cardiology, Saiseikai Kumamoto Hospital, 5-3-1 Chikami, Minami-ku, Kumamoto 861-4193, Japan
| | - Koichi Inoue
- Division of Cardiology, National Hospital Organization Osaka National Hospital, 2-1-14 Houenzaka, Chuo-ku, Osaka 540-0006, Japan
- Cardiovascular Center, Sakurabashi Watanabe Hospital, 2-4-32 Umeda, Kita-ku, Osaka 530-0001, Japan
| | - Masahiko Goya
- Department of Cardiovascular Medicine, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
| | - Hideki Origasa
- The Institute of Statistical Mathematics, 10-3 Midori-cho, Tachikawa, Tokyo 190-8562, Japan
| | - Makiho Yamazaki
- Department of Clinical Research, Johnson & Johnson K.K. Medical Company,Chiyoda First Building West Tower, 3-5-2 Nishi-Kanda, Chiyoda-ku, Tokyo 101-0065, Japan
| | - Akihiko Nogami
- Department of Cardiology, Institute of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan
| |
Collapse
|
18
|
Zhang R, Chu H, Liu S, Yang B, Han B, Xiao X, Ma C, Sun Y, Yin X, Xia Y, Gao L. Catheter ablation of atrial fibrillation using FireMagic TrueForce ablation catheter: The TRUEFORCE trial. Pacing Clin Electrophysiol 2023; 46:986-993. [PMID: 37334721 DOI: 10.1111/pace.14751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/10/2023] [Accepted: 05/29/2023] [Indexed: 06/20/2023]
Abstract
BACKGROUND The use of contact force (CF) sensing catheters has provided a revolutionary improvement in catheter ablation (CA) of atrial fibrillation (AF) in the past decade. However, the success rate of CA for AF remains limited, and some complications still occur. METHODS The TRUEFORCE trial (Catheter Ablation of Atrial Fibrillation using FireMagic TrueForce Ablation Catheter) is a multicenter, prospective, single-arm objective performance criteria study of AF patients who underwent their first CA procedure using FireMagic TrueForce ablation catheter. RESULTS A total of 120 patients (118 with paroxysmal AF) were included in this study, and 112 patients included in the per-protocol analysis. Pulmonary vein isolation (PVI) was achieved in 100% of the patients, with procedure and fluoroscopy time of 146.63 ± 40.51 min and 12.89 ± 5.59 min, respectively. Freedom from recurrent atrial arrhythmia after ablation was present 81.25% (95% confidence interval [CI]: 72.78%-88.00%) of patients. No severe adverse events (death, stroke/transient ischemic attack [TIA], esophageal fistula, myocardial infarction, thromboembolism, or pulmonary vein stenosis) were detected during the follow-up. Four (4/115, 3.33%) adverse events were documented, including one abdominal discomfort, one femoral artery hematoma, one coughing up blood, and one postoperative palpitation and insomnia. CONCLUSIONS This study demonstrated the clinical feasibility of FireMagic force-sensing ablation catheter in CA of AF, with a satisfactory short- and long-term efficacy and safety.
Collapse
Affiliation(s)
- Rongfeng Zhang
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Huimin Chu
- Department of Cardiology, Ningbo First Hospital, Ningbo, China
| | - Shaowen Liu
- Department of Cardiology, Shanghai General Hospital, Shanghai, China
| | - Bing Yang
- Department of Cardiology, Dongfang Hospital Affiliated to Tongji University, Shanghai, China
| | - Bing Han
- Department of Cardiology, Xuzhou Central Hospital, Xuzhou, China
| | - Xianjie Xiao
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Chengming Ma
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yuanjun Sun
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Xiaomeng Yin
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yunlong Xia
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Lianjun Gao
- Department of Cardiology, Institute of Cardiovascular Diseases, First Affiliated Hospital of Dalian Medical University, Dalian, China
| |
Collapse
|
19
|
Chen G, Li G, Zhang D, Wang X, Guo X. Blanking period antiarrhythmic drugs after catheter ablation for atrial fibrillation: a meta-analysis of randomized controlled trials. Front Cardiovasc Med 2023; 10:1071950. [PMID: 37547248 PMCID: PMC10397410 DOI: 10.3389/fcvm.2023.1071950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 07/04/2023] [Indexed: 08/08/2023] Open
Abstract
Background Antiarrhythmic drugs (AADs) are frequently prescribed following catheter ablation (CA) for atrial fibrillation (AF). However, to date, there is a lack of large-scale, multicenter controlled studies that have confirmed the efficacy of AADs in reducing the incidence of late recurrence of AF after CA. Furthermore, the optimal duration of short-term use of AADs after CA remains a controversial topic. Methods PubMed, Embase, Cochrane Library, CNKI, and ClinicalTrials.gov were searched until April 25, 2022. We conducted a meta-analysis of randomized controlled trials (RCTs) to assess the efficacy of blanking period AADs in predicting both early and late recurrence of AF. In addition, Grading of Recommendations Assessment, Development and Evaluation (GRADE) was used to assess the quality of evidence in this meta-analysis. Results 12 RCTs with 3,625 patients were included in this meta-analysis. Short-term use of AADs after AF ablation reduced the risk of early recurrence of AF compared with the no-AADs group. In the subgroup analysis of AADs use time, it was found that only using AADs for more than 2 months can reduce the early recurrence of AF after CA. However, when compared with the no-AADs group, short-term use of AADs after CA did not reduce the incidence of late recurrence of AF. Conclusions Short-term use of AADs (more than 2 months) can reduce the early recurrence but not the late recurrence of AF after CA.
Collapse
Affiliation(s)
- Gang Chen
- Department of Cardiology, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| | - Guangling Li
- Department of Cardiology, Lanzhou University Second Hospital, The Second Clinical Medical College of Lanzhou University, Lanzhou, China
| | - Demei Zhang
- Department of Cardiology, Lanzhou University Second Hospital, The Second Clinical Medical College of Lanzhou University, Lanzhou, China
| | - Xiaomei Wang
- Department of Cardiology, Lanzhou University Second Hospital, The Second Clinical Medical College of Lanzhou University, Lanzhou, China
| | - Xueya Guo
- Department of Cardiology, Lanzhou University Second Hospital, Lanzhou University, Lanzhou, China
| |
Collapse
|
20
|
Miller J, Sewani A, Rezazada J, Alawneh Y, Kazemian P, Terricabras M, Wright G, Tavallaei MA. Quantification of Mechanical Characteristics of Conventional Steerable Ablation Catheters for Treatment of Atrial Fibrillation Using a Heart Phantom. Cardiovasc Eng Technol 2023; 14:419-427. [PMID: 36828976 DOI: 10.1007/s13239-023-00662-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 02/06/2023] [Indexed: 02/26/2023]
Abstract
PURPOSE Accurate and reliable catheter navigation is important in formation of adequate lesions during radiofrequency cardiac catheter ablation. To inform future device design efforts and to characterize the limitations of conventional devices, the focus of this study is to assess and quantify the mechanical performance of manual ablation catheters for pulmonary vein isolation procedures within a phantom heart model. METHODS We measured three important metrics: accuracy of catheter tip navigation to target anatomical landmarks at the pulmonary veins (PVs), orientation of the catheter relative to the tissue at the targets, and the delivered force values and their stability and variations at those targets. A stereovision system was used for navigational guidance and to measure the catheter's tip position and orientation relative to the targets. To measure force, piezoelectric sensors were used which were integrated at the targets, whereby operators were instructed to stabilize the catheter to achieve a chosen reference force value. RESULTS An overall positioning accuracy of 1.57 ± 1.71 mm was achieved for all targets. No statistical significance was observed in position accuracy between the right and left PVs (p = 0.5138). The orientation of the catheter relative to tissue surface was 41° ± 21° with no statistical significance between targets. The overall force stability was 41 ± 6 g with higher difficulty in force stabilization in the right compared to the left PV (40 ± 8 vs. 43 ± 2 g, p < 0.0001). CONCLUSION Based on our results, future improvements to manual catheter navigation for ablation should focus on improving device performance in orientation control and improved force stability.
Collapse
Affiliation(s)
- Jacob Miller
- Toronto Metropolitan University, Toronto, ON, Canada.
- Sunnybrook Research Institute, Toronto, ON, Canada.
| | - Alykhan Sewani
- Toronto Metropolitan University, Toronto, ON, Canada
- Sunnybrook Research Institute, Toronto, ON, Canada
| | - Jeffrey Rezazada
- Toronto Metropolitan University, Toronto, ON, Canada
- Sunnybrook Research Institute, Toronto, ON, Canada
| | - Yara Alawneh
- Toronto Metropolitan University, Toronto, ON, Canada
- Sunnybrook Research Institute, Toronto, ON, Canada
| | | | | | | | - M Ali Tavallaei
- Toronto Metropolitan University, Toronto, ON, Canada
- Sunnybrook Research Institute, Toronto, ON, Canada
| |
Collapse
|
21
|
Baran J, Skrzyńska-Kowalczyk M, Piotrowski R, Sikorska A, Kryński T, Kułakowski P. Is catheter-tissue contact force value important for ablation of ventricular arrhythmias originating from the left ventricular papillary muscles? Front Cardiovasc Med 2023; 10:1166810. [PMID: 37273878 PMCID: PMC10235700 DOI: 10.3389/fcvm.2023.1166810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Accepted: 05/04/2023] [Indexed: 06/06/2023] Open
Abstract
Background Good catheter-tissue contact is mandatory to create effective ablation lesions. The minimal contact force value for ablation of arrhythmias originating from the left ventricle is 8.0-10.0 grams but is not known for arrhythmias arising from papillary muscles. Purpose To analyze contact force values during successful ablation procedures of arrhythmias originating from the left ventricular papillary muscles. Methods 24 consecutive patients (mean age 57.9 ± 11.9 years, 16 males) underwent ablation of premature ventricular complexes originating from left ventricular papillary muscles with the use of CARTO electro-anatomical system and intracardiac echocardiography. Results Acute complete abolition of ventricular ectopy was obtained in 23 (96%) patients. The fluoroscopy time was 3.9 ± 3.5 min and procedure duration - 114.8 ± 37.9 min. The mean contact force during successful ablations was 3.0 ± 1.1 grams and 3.18 ± 1.8 grams for antero-lateral and postero-medial papillary muscle, respectively (NS). The mean contact force during a single unsuccessful ablation was 3.0 grams. At control Holter ECG, the mean Ectopy Burden was Reduced in the Antero-Lateral Papillary Muscle Group from 18.0% ± 7.9% to 2.6% ± 2.9% (p = 0.005415) and in the Postero-Medial Papillary Muscle Group - from 34.8% ± 13.7%-1.7% ± 1.3% (p = 0.012694). During Median 27 (IQR: 17-34) Months of Follow-up There one Recurrence of Arrhythmia. Conclusion The values of contact force for successful ablation of ventricular ectopy originating from the left ventricular papillary muscles may be much lower than those for ablation of other foci which questions the role of contact force measurement when ablating these arrhythmias.
Collapse
Affiliation(s)
- Jakub Baran
- Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland
| | - Martyna Skrzyńska-Kowalczyk
- Department of Internal Medicine and Cardiology University Clinical Center, Medical University of Warsaw, Warsaw, Poland
| | - Roman Piotrowski
- Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland
| | - Agnieszka Sikorska
- Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland
| | - Tomasz Kryński
- Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland
| | - Piotr Kułakowski
- Division of Clinical Electrophysiology, Department of Cardiology, Centre of Postgraduate Medical Education, Grochowski Hospital, Warsaw, Poland
| |
Collapse
|
22
|
Canpolat U. Reconduction (reconnection or gap) after pulmonary vein isolation for paroxysmal atrial fibrillation ablation is a multifactorial process rather than a battle of fire and ice alone! J Cardiovasc Electrophysiol 2023; 34:1326-1328. [PMID: 36786512 DOI: 10.1111/jce.15857] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Accepted: 02/07/2023] [Indexed: 02/15/2023]
Affiliation(s)
- Ugur Canpolat
- Department of Cardiology, Arrhythmia and Electrophysiology Unit, Hacettepe University Faculty of Medicine, Ankara, Turkey
| |
Collapse
|
23
|
Lou Y, Yang T, Luo D, Wu J, Dong Y. A Novel Catheter Distal Contact Force Sensing for Cardiac Ablation Based on Fiber Bragg Grating with Temperature Compensation. SENSORS (BASEL, SWITZERLAND) 2023; 23:2866. [PMID: 36905071 PMCID: PMC10007298 DOI: 10.3390/s23052866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 02/19/2023] [Accepted: 03/03/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVE To accurately achieve distal contact force, a novel temperature-compensated sensor is developed and integrated into an atrial fibrillation (AF) ablation catheter. METHODS A dual elastomer-based dual FBGs structure is used to differentiate the strain on the two FBGs to achieve temperature compensation, and the design is optimized and validated by finite element simulation. RESULTS The designed sensor has a sensitivity of 90.5 pm/N, resolution of 0.01 N, and root-mean-square error (RMSE) of 0.02 N and 0.04 N for dynamic force loading and temperature compensation, respectively, and can stably measure distal contact forces with temperature disturbances. CONCLUSION Due to the advantages, i.e., simple structure, easy assembly, low cost, and good robustness, the proposed sensor is suitable for industrial mass production.
Collapse
Affiliation(s)
- Yuyang Lou
- School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing 401331, China
- Opto-Electronic Engineering and Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Tianyu Yang
- Opto-Electronic Engineering and Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Dong Luo
- Opto-Electronic Engineering and Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Jianwei Wu
- School of Physics and Electronic Engineering, Chongqing Normal University, Chongqing 401331, China
| | - Yuming Dong
- Opto-Electronic Engineering and Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
24
|
Sørensen SK, Johannessen A, Worck R, Hansen ML, Ruwald MH, Hansen J. Differential gap location after radiofrequency versus cryoballoon pulmonary vein isolation: Insights from a randomized trial with protocol-mandated repeat procedure. J Cardiovasc Electrophysiol 2023; 34:519-526. [PMID: 36640430 DOI: 10.1111/jce.15821] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Revised: 01/04/2023] [Accepted: 01/10/2023] [Indexed: 01/15/2023]
Abstract
INTRODUCTION Reconnections to pulmonary vein (PV) triggers of atrial fibrillation (AF) are the primary cause of AF recurrence after PV isolation (PVI) with radiofrequency (RF) or cryoballoon catheter ablation (CRYO), but method-specific contributions to PV reconduction pattern and conductive gap location are incompletely understood. METHODS The objective of this radiofrequency versus cryoballoon catheter ablation for paroxysmal atrial fibrillation substudy was to determine procedure-specific patterns of PV reconduction in a randomized population with protocol-mandated repeat procedures, irrespective of AF recurrence. Each PV was assessed in turn and PV reconnection sites were identified by high-density electroanatomical mapping and locating the earliest activation site. Gap locations were verified by PV re-isolation. RESULTS In 98 patients, 81% versus 76% previously isolated PVs remained isolated after CRYO versus RF (risk ratio [RR]: 1.06; 95% confidence interval [CI]: 0.96-1.18; p = .28). There were no significant differences for any PV: left superior PV: 90% versus 80%; left inferior PV: 80% versus 78%; right superior PV: 81% versus 80%, and right inferior PV: 76% versus 73%. For each reconnected PV, 34% of ipsilateral PVs were also reconnected after CRYO compared with 64% after RF (RR: 0.54; 95% CI: 0.32-0.90; p = .01). After RF, gaps were clustered by the carina and adjacent segments, whereas they were more heterogeneously distributed after CRYO. CONCLUSION Although RF and CRYO produce similar proportions of durably isolated PVs, gap locations appear to develop in procedure-specific patterns. After RF, ipsilateral PV reconduction is more frequent and gap sites cluster by the carina, suggesting that this region should be selectively ablated for more durable PVI.
Collapse
Affiliation(s)
- Samuel K Sørensen
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark
| | - Arne Johannessen
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark
| | - René Worck
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark
| | - Morten L Hansen
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark
| | - Martin H Ruwald
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark
| | - Jim Hansen
- Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark
| |
Collapse
|
25
|
Sauer WH, Kreidieh O. Precision Medicine and Ablation of Ventricular Arrhythmias. JACC Clin Electrophysiol 2023; 9:341-344. [PMID: 36990596 DOI: 10.1016/j.jacep.2022.10.037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 10/23/2022] [Indexed: 03/29/2023]
|
26
|
Radiofrequency ablation using the second-generation temperature-controlled diamond tip system in paroxysmal and persistent atrial fibrillation: results from FASTR-AF. J Interv Card Electrophysiol 2023; 66:343-351. [PMID: 35581464 DOI: 10.1007/s10840-022-01234-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Accepted: 04/24/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Catheter ablation (CA) technology development reflects the need to improve the effectiveness of atrial fibrillation (AF) treatment. Recently, the DiamondTemp Ablation (DTA) RF generator software was updated with a more responsive power ramp. METHODS DIAMOND FASTR-AF was a prospective, single-arm, multicenter trial. This study sought to characterize the performance of the updated DTA system for the treatment of patients with drug-refractory paroxysmal and persistent AF (PAF and PsAF). The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence following a 90-day blanking period through 12 months, and the primary safety endpoint was a composite of serious adverse events. RESULTS In total, 60 subjects (34 PAF and 26 PsAF) underwent CA at three centers. Patients were 71.7% male, (age 63.9 ± 10.2 years, with an AF diagnosis duration 3.1 ± 3.9 years and left atrial size 4.4 ± 0.8 cm). Pulmonary vein isolation-only ablation strategy was performed in 34 (56.7%) subjects. The procedural characteristics show a procedure time 90.8 ± 31.6 min, total RF time 14.7 ± 7.7 min, ablation duration 10.7 ± 3.6 s, and fluid infusion 284.7 ± 111.5 ml. The serious adverse event rate was 8.3% (5/60), 3 pulmonary edema and 2 extended hospitalizations. Freedom from atrial arrhythmia recurrence was achieved in 67.6% of subjects by 12 months. CONCLUSIONS The updated DTA system demonstrated long-term safety and effectiveness through 12 months of post-ablation follow-up for patients with atrial fibrillation. Additionally, procedures were demonstrated to be highly efficient with short procedure times and low levels of fluid infusion. TRIAL REGISTRATION Sponsored by Medtronic, Inc.; FASTR-AF ClinicalTrials.gov; NCT03626649.
Collapse
|
27
|
Bohnen M, Weber R, Minners J, Jadidi A, Eichenlaub M, Neumann FJ, Arentz T, Lehrmann H. Characterization of circumferential antral pulmonary vein isolation areas resulting from pulsed-field catheter ablation. Europace 2023; 25:65-73. [PMID: 35852306 PMCID: PMC10103571 DOI: 10.1093/europace/euac111] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 06/09/2022] [Indexed: 11/13/2022] Open
Abstract
AIMS The cornerstone of pulmonary vein (PV) isolation (PVI) is a wide-area circumferential ablation (WACA) resulting in an antral PVI area. Pulsed-field ablation (PFA) is a new nonthermal 'single-shot' PVI technique resulting in well-characterized posterior isolation areas. However, information on circumferential PVI area is lacking. Thus, we sought to characterize the circumferential antral PVI areas after PFA-PVI. METHODS AND RESULTS Atrial fibrillation (AF) patients underwent fluoroscopy-guided PVI with a pentaspline PFA catheter. Ultra-high-density voltage maps using a 20-polar circular mapping catheter were created before and immediately after PVI to identify and quantify (i) insufficient isolation areas per antral PV segment (10-segment model) and (ii) enlarged left atrial (LA) isolation areas (beyond the antral PV segments) per LA region (8-region model). The PFA-PVI with pre- (5469 ± 1822 points) and post-mapping (6809 ± 2769 points) was performed in 40 consecutive patients [age 62 ± 6 years, 25/40 (62.5%) paroxysmal AF]. Insufficient isolation areas were located most frequently in the anterior antral PV segments of the left PVs (62.5-77.5% of patients) with the largest extent (median ≥0.4 cm2) located in the same segments (segments 2/5/8). Enlarged LA isolation areas were located most frequently and most extensively on the posterior wall and roof region (89.5-100% of patients; median 1.1-2.7 cm2 per region). CONCLUSION Fluoroscopy-guided PFA-PVI frequently results in insufficient isolation areas in the left anterior antral PV segments and enlarged LA isolation areas on the posterior wall/roof, which both may be extensive. To optimize the procedure, full integration of PFA catheter visualization into three-dimensional-mapping systems is needed.
Collapse
Affiliation(s)
- Marius Bohnen
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Reinhold Weber
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Jan Minners
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Amir Jadidi
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Martin Eichenlaub
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Franz-Josef Neumann
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Thomas Arentz
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| | - Heiko Lehrmann
- Department of Cardiology and Angiology II (Campus Bad Krozingen), Heart Center, University Hospital Freiburg, Südring 15, 79189 Bad Krozingen, Germany
| |
Collapse
|
28
|
Mujović NM, Marinković MM, Marković N, Kocijančić A, Kovačević V, Vučićević V, Mujović NM, Potpara TS. Risk factors for late reconnections after circumferential pulmonary vein isolation guided by lesion size index - Data from repeat invasive electrophysiology procedure. Front Cardiovasc Med 2023; 9:986207. [PMID: 36776941 PMCID: PMC9908948 DOI: 10.3389/fcvm.2022.986207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 12/29/2022] [Indexed: 01/27/2023] Open
Abstract
Background Late reconnections (LR) of pulmonary veins (PVs) after wide antral circumferential ablation (WACA) using point-to-point radiofrequency (RF) ablation are common. Lesion size index (LSI) is a novel marker of lesion quality proposed by Ensite Precision mapping system, expected to improve PV isolation durability. This study aimed to assess the durability of LSI-guided PVI and the risk factors for LR of PVs. Methods The prospective study included 33 patients with paroxysmal atrial fibrillation (PAF) who underwent (1) the index LSI-guided WACA procedure (with target LSI of 5.5-6.0 for anterior and 5.0-5.5 for posterior WACA segments) and (2) the 3-month protocol-mandated re-mapping procedure in all patients, irrespective of AF recurrence after the index procedure. Ablation parameters reported by Ensite mapping system were collected retrospectively. The inter-lesion distance (ILD) between all adjacent WACA lesions was calculated off-line. Association between index ablation parameters and the LRs of PVs at 3 months was analyzed. Results The median patient age was 61 (IQR: 53-64) years and 55% of them were males. At index procedure, the first-pass WACA isolation rate was higher for the left PVs than the right PVs (64 vs. 33%, p = 0.014). In addition, a low acute reconnection rates were observed, as follows: in 12.1% of patients, in 6.1% of WACA circles, in 3.8% of WACA segments and in 4.5% of PVs. However, the 3-month remapping study revealed LR of PV in 63.6% of patients, 37.9% of WACA circles, 20.5% of WACA segments and 26.5% of PVs. The LRs were identified mostly along the left anterior WACA segment. Independent risk factors for the LR of WACA were left-sided WACA location (OR 3.216 [95%CI: 1.065-9.716], p = 0.038) and longer ILD (OR 1.256 [95%CI: 1.035-1.523] for each 1-mm increase, p = 0.021). The ILD of > 8.0 mm showed a predictive value for the LR of WACA, with the sensitivity of 84% and specificity of 46%. A single case of cardiac tamponade occurred following the re-mapping invasive procedure. No other complications were encountered. Conclusion Although the LSI-guided PVI ensures a consistent PVI during the index procedure, LRs of PVs are still common. Besides the LSI, the PVI durability requires an optimal ILD between adjacent lesions, especially along the anterior lateral ridge.
Collapse
Affiliation(s)
- Nebojša M. Mujović
- Cardiology Clinic, University Clinical Center of Serbia, Belgrade, Serbia,Faculty of Medicine, University of Belgrade, Belgrade, Serbia,*Correspondence: Nebojša M. Mujović,
| | - Milan M. Marinković
- Cardiology Clinic, University Clinical Center of Serbia, Belgrade, Serbia,Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Nebojša Marković
- Cardiology Clinic, University Clinical Center of Serbia, Belgrade, Serbia,Mount Sinai Heart, Icahn School of Medicine at Mount Sinai, New York, NY, United States
| | - Aleksandar Kocijančić
- Cardiology Clinic, University Clinical Center of Serbia, Belgrade, Serbia,Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| | - Vladan Kovačević
- Cardiology Clinic, University Clinical Center of Serbia, Belgrade, Serbia
| | - Vera Vučićević
- Center for Anesthesiology, University Clinical Center of Serbia, Belgrade, Serbia
| | - Nataša M. Mujović
- Faculty of Medicine, University of Belgrade, Belgrade, Serbia,Center for Physical Medicine and Rehabilitation, University Clinical Center of Serbia, Belgrade, Serbia
| | - Tatjana S. Potpara
- Cardiology Clinic, University Clinical Center of Serbia, Belgrade, Serbia,Faculty of Medicine, University of Belgrade, Belgrade, Serbia
| |
Collapse
|
29
|
Nakagawa H, Ikeda A, Yokoyama K, An Y, Hussein AA, Saliba WI, Wazni OM, Castellvi Q. Improvement in Lesion Formation with Radiofrequency Energy and Utilization of Alternate Energy Sources (Cryoablation and Pulsed Field Ablation) for Ventricular Arrhythmia Ablation. Card Electrophysiol Clin 2022; 14:757-767. [PMID: 36396191 DOI: 10.1016/j.ccep.2022.08.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Current ablation systems rely on thermal energy to produce ablation lesions (heating: RF, laser and ultrasound, and cooling: cryo-thermia). While thermal ablation has been proven to be effective, there are several limitations: 1) relatively long procedural times; 2) high recurrence rate of ventricular arrhythmias; and 3) excessive heating potentially leading to serious complications, including steam pop (perforation), coronary arterial injury and thrombo-embolism. Pulsed field ablation (PFA)/irreversible electroporation (IRE) offers a unique non-thermal ablation strategy which has the potential to overcome these limitations. Recent pre-clinical studies suggest that PFA/IRE might be effective and safe for the treatment of cardiac arrhythmias.
Collapse
Affiliation(s)
- Hiroshi Nakagawa
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA.
| | - Atsushi Ikeda
- Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Katsuaki Yokoyama
- Department of Medicine, Nihon University School of Medicine, Tokyo, Japan
| | - Yoshimori An
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA
| | - Ayman A Hussein
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA
| | - Walid I Saliba
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA
| | - Oussama M Wazni
- Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, OH, USA
| | - Quim Castellvi
- Department of Information and Communications Technologies, Pompeu Fabra University, Barcelona, Spain
| |
Collapse
|
30
|
Benali K, Lai VD, Hammache N, Magnin-Poull I, de Chillou C, Sellal JM. Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters. J Interv Card Electrophysiol 2022; 66:931-940. [PMID: 36251129 DOI: 10.1007/s10840-022-01393-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Accepted: 10/03/2022] [Indexed: 10/24/2022]
Abstract
BACKGROUND Pulmonary vein (PV) isolation (PVI) has become the cornerstone of atrial fibrillation (AF) ablation in patients with paroxysmal AF (PAF). PVI durability is influenced by many factors including PVs anatomy. Data regarding the influence of PVs anatomical variations on the outcomes of PAF ablation in the era of contact force-sensing ablation catheters are scarce and contradictory. METHODS Consecutive patients referred to our center for a first ablation of PAF using radiofrequency (RF) were included. PVs anatomy was classified into 3 groups: typical anatomy (4 distinct veins), left common ostium (LCO), and right accessory PV (RAPV). The primary outcome was recurrence of atrial arrhythmia episode during a 12-month follow-up after ablation. RESULTS Two hundred twenty-three patients were included (mean age 58.4 ± 10.8 years and 70.9% male). Among this cohort, 141 patients (63.2%) had typical PV anatomy, 53 (23.8%) had a LCO, and 29 (13.0%) had a RAPV. The existence of a RAPV was not associated with a higher rate of AF recurrences (22 (14.3%) vs. 7 (10.1%), p = 0.519). After multivariate analysis, the presence of an LCO did not appear to be associated with the AF recurrence rate at 12 months (OR = 1.69, 95%CI 0.95-2.49, p = 0.098). Maintenance of antiarrhythmic drugs after ablation was the only factor independently associated with a decreased risk of AF recurrence at 12 months (OR = 0.76, 95%CI 0.60-0.97, p = 0.046). CONCLUSION This study suggests that the presence of an LCO or a RAPV is not associated with a higher rate of AF recurrence at 12 months after radiofrequency PVI using contact force-sensing catheters in PAF patients.
Collapse
Affiliation(s)
- Karim Benali
- Department of Cardiology, CHU de Saint-Etienne, 42270, Saint-Priest-En-Jarez, France. .,INSERM-IADI, U1254, F-54500, Vandœuvre lès-Nancy, France.
| | - Van Duc Lai
- INSERM-IADI, U1254, F-54500, Vandœuvre lès-Nancy, France.,Department of Cardiology, CHRU de Nancy, 54500, Vandœuvre lès-Nancy, France
| | - Nefissa Hammache
- INSERM-IADI, U1254, F-54500, Vandœuvre lès-Nancy, France.,Department of Cardiology, CHRU de Nancy, 54500, Vandœuvre lès-Nancy, France
| | - Isabelle Magnin-Poull
- INSERM-IADI, U1254, F-54500, Vandœuvre lès-Nancy, France.,Department of Cardiology, CHRU de Nancy, 54500, Vandœuvre lès-Nancy, France
| | - Christian de Chillou
- INSERM-IADI, U1254, F-54500, Vandœuvre lès-Nancy, France.,Department of Cardiology, CHRU de Nancy, 54500, Vandœuvre lès-Nancy, France
| | - Jean-Marc Sellal
- INSERM-IADI, U1254, F-54500, Vandœuvre lès-Nancy, France.,Department of Cardiology, CHRU de Nancy, 54500, Vandœuvre lès-Nancy, France
| |
Collapse
|
31
|
Guckel D, Lucas P, Isgandarova K, Hamriti ME, Bergau L, Fink T, Sciacca V, Braun M, Khalaph M, Imnadze G, Nölker G, Sommer P, Sohns C. Impact of pulmonary vein variant anatomy and cross-sectional orifice area on freedom from atrial fibrillation recurrence after cryothermal single-shot guided pulmonary vein isolation. J Interv Card Electrophysiol 2022; 65:251-260. [PMID: 35764853 PMCID: PMC9550688 DOI: 10.1007/s10840-022-01279-w] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 06/12/2022] [Indexed: 10/25/2022]
Abstract
BACKGROUND Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This study aimed to evaluate ablation efficacy and freedom from arrhythmia recurrence using the novel POLARx compared to the Arctic Front Advance Pro (AFA) CB system including the analysis of individual PV characteristics. METHODS A total of 687 patients underwent CB-guided ablation for AF. Arrhythmia recurrence was defined as an ECG documented episode of any AF/atrial tachycardia (AT) > 30 s. Anatomical characteristics were assessed using magnetic resonance imaging (MRI). For each PV, the cross-sectional orifice area (CSOA) was determined. Follow-up examinations were scheduled after 3, 6, and 12 months. RESULTS Acute PVI was achieved in all patients. Twelve-month AF-free survival was similar between the groups (POLARx 43/86 (50%) vs. AFA 318/601 (53%), Log-rank (LR) p = 0.346). MRI found a comparable percentage of patients with normal PV anatomy (POLARx 71/86 (83%) vs. AFA 530/601 (85%), p = 0.162). Patients with variant PV characteristics presented with a significantly impaired 12-month AF-free survival (normal PVs 326/585 (56%) vs. variant PVs 27/102 (27%), LR p < 0.001) independent of the applied CB ablation system. PAF patients with AF recurrence presented with significantly larger CSOA of the left-sided PVs and the right superior PVs (LSPV: p < 0.001; LIPV: p < 0.001; RSPV: p < 0.001). In PERS AF, no association between CSOA and ablation outcome was observed. Multivariate analyses identified PERS AF (hazard ratio (HR) 2.504, confidence interval (CI), 1.900-3.299, p < 0.001) and variant PV anatomy (HR 2.124, CI 1.608-2.805, p < 0.001) as independent predictors for AF recurrence. CONCLUSIONS Both CB ablation systems are associated with comparable 12-month AF-free survival rates. Variant PV anatomy seems to be predictive for AF recurrence. An association between CSOA and the outcome after CB-guided PVI was demonstrated for PAF.
Collapse
Affiliation(s)
- Denise Guckel
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Philipp Lucas
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Khuraman Isgandarova
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Mustapha El Hamriti
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Leonard Bergau
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Thomas Fink
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Vanessa Sciacca
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Martin Braun
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Moneeb Khalaph
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Guram Imnadze
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Georg Nölker
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
- Clinic for Internal Medicine II/Cardiology, Christliches Klinikum Unna Mitte, Unna, Germany
| | - Philipp Sommer
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany
| | - Christian Sohns
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
| |
Collapse
|
32
|
Lévy S, Steinbeck G, Santini L, Nabauer M, Penela D, Kantharia BK, Saksena S, Cappato R. Management of atrial fibrillation: two decades of progress - a scientific statement from the European Cardiac Arrhythmia Society. J Interv Card Electrophysiol 2022; 65:287-326. [PMID: 35419669 DOI: 10.1007/s10840-022-01195-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/25/2021] [Accepted: 03/21/2022] [Indexed: 02/07/2023]
Abstract
BACKGROUND Atrial fibrillation (AF) is the most common sustained arrhythmia encountered in clinical practice. The aim of this review was to evaluate the progress made in the management of AF over the two last decades. RESULTS Clinical classification of AF is usually based on the presence of symptoms, the duration of AF episodes and their possible recurrence over time, although incidental diagnosis is not uncommon. The majority of patients with AF have associated cardiovascular diseases and more recently the recognition of modifiable risk factors both cardiovascular and non-cardiovascular which should be considered in its management. Among AF-related complications, stroke and transient ischaemic accidents (TIAs) carry considerable morbidity and mortality risk. The use of implantable devices such as pacemakers and defibrillators, wearable garments and subcutaneous cardiac monitors with recording capabilities has enabled to access the burden of "subclinical AF". The recent introduction of non-vitamin K antagonists has led to improve the prevention of stroke and peripheral embolism. Agents capable of reversing non-vitamin K antagonists have also become available in case of clinically relevant major bleeding. Transcatheter closure of left atrial appendage represents an option for patients unable to take oral anticoagulation. When treating patients with AF, clinicians need to select the most suitable strategy, i.e. control of heart rate and/or restoration and maintenance of sinus rhythm. The studies comparing these two strategies have not shown differences in terms of mortality. If an AF episode is poorly tolerated from a haemodynamic standpoint, electrical cardioversion is indicated. Otherwise, restoration of sinus rhythm can be obtained using intravenous pharmacological cardioversion and oral class I or class III antiarrhythmic is used to prevent recurrences. During the last two decades after its introduction in daily practice, catheter ablation has gained considerable escalation in popularity. Progress has also been made in AF associated with heart failure with reduced or preserved ejection fraction. CONCLUSIONS Significant progress has been made within the past 2 decades both in the pharmacological and non-pharmacological managements of this cardiac arrhythmia.
Collapse
Affiliation(s)
- Samuel Lévy
- Marseille School of Medicine, Aix-Marseille University, Marseille, France.
| | | | - Luca Santini
- Cardiology Division, G. B. Grassi Hospital, Via G. Passeroni 28, Ostia Lido, RM, Italy
| | - Michael Nabauer
- Klinikum Der Universität München, Ludwig-Maximilians-University, Munich, Germany
| | - Diego Penela
- Arrhythmia & Electrophysiology Center IRCCS Multimedica Via Milanese 300, Sesto San Giovanni, Milan, Italy
| | - Bharat K Kantharia
- Cardiovascular and Heart Rhythm Consultants, 30 West 60th Street, Suite 1U, New York, NY, 10023, USA
| | - Sanjeev Saksena
- Rutgers-Robert Wood Johnson Medical School, Piscataway, NJ, USA
| | - Riccardo Cappato
- Arrhythmia & Electrophysiology Center IRCCS Multimedica Via Milanese 300, Sesto San Giovanni, Milan, Italy
| |
Collapse
|
33
|
Hsu JC, Darden D, Glover BM, Colley BJ, Steinberg C, Thibault B, Jewell C, Bernard M, Tabereaux PB, Siddiqui U, Li J, Horvath EE, Cooper D, Lin D. Performance and acute procedural outcomes of the EnSite Precision™ cardiac mapping system for electrophysiology mapping and ablation procedures: results from the EnSite Precision™ observational study. J Interv Card Electrophysiol 2022; 65:141-151. [PMID: 35536500 PMCID: PMC9550718 DOI: 10.1007/s10840-022-01239-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 04/25/2022] [Indexed: 11/30/2022]
Abstract
BACKGROUND The EnSite Precision™ cardiac mapping system (Abbott) is a catheter navigation and mapping system capable of displaying the three-dimensional (3D) position of conventional and sensor-enabled electrophysiology catheters, as well as displaying cardiac electrical activity as waveform traces and dynamic 3D maps of cardiac chambers. The EnSite Precision™ Observational Study (NCT-03260244) was designed to quantify and characterize the use of the EnSite Precision™ cardiac mapping system for mapping and ablation of cardiac arrhythmias in a real-world environment and evaluate procedural outcomes. METHODS A total of 1065 patients were enrolled at 38 centers in the USA and Canada between 2017 and 2018 and were followed for 12 months post procedure for arrhythmia recurrence, medication use, and quality-of-life changes. Eligible subjects were adults undergoing a cardiac electrophysiology mapping and radiofrequency ablation procedure using the EnSite Precision™ System. RESULTS A final cohort of 925 patients (64.3 years of age, 30.2% female) were analyzed. The primary procedural indication was atrial flutter in 48.1% (445/925), atrial fibrillation in 46.5% (430/925), and other arrhythmias in 5% (50/925). Electroanatomic mapping was performed in 81.5% (754/925) of patients. Mapping was stable throughout 79.8% (738/925) of procedures with initial mapping time of 8.6 min (IQR 4.7-15.0). Average mapping efficiency created with AutoMap or TurboMap was 164.9 ± 365.7 used points per minute. Median number of mapping points collected and used was 1752.5 and 811.0, respectively. Only 335/925 (36.2%) required editing and 66.0% (221/335) of these patients required editing of less than 10 points. Fluoroscopy was utilized in most cases (n = 811/925, 87.4%) with fluoroscopy time of 11.0 min (IQR 6.0-18.0). Overall median procedure time was 101.0 min (IQR 59.0-152.0). Acute procedural success was high for both atrial fibrillation (n = 422/430, 98.1%) and atrial flutter (n = 434/445, 97.5%). CONCLUSION In a real-world study analysis, use of the EnSite Precision™ mapping system was associated with high procedural stability, short mapping times, high point density requiring infrequent editing, low fluoroscopy time, and high prevalence of acute procedural success.
Collapse
Affiliation(s)
- Jonathan C Hsu
- University of California San Diego, 4952 Medical Center Dr, ACTRI Bldg, 3rd Floor, Room 3E-313, MC7411, La Jolla, CA, 92037, USA.
| | - Douglas Darden
- University of California San Diego, 4952 Medical Center Dr, ACTRI Bldg, 3rd Floor, Room 3E-313, MC7411, La Jolla, CA, 92037, USA
| | | | | | - Christian Steinberg
- Institut Universitaire de Cardiologie Et Pneumologie de Québec (IUCPQ-UL), Laval University, Quebec, Canada
| | | | - Coty Jewell
- Oklahoma Heart Hospital South, Oklahoma City, OK, USA
| | | | | | | | - Jingyun Li
- Abbott Laboratories, Zephyrhills, FL, USA
| | | | - Daniel Cooper
- Washington University School of Medicine, St. Louis, MO, USA
| | - David Lin
- Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
34
|
Groen MHA, van Driel VJHM, Neven K, van Wessel H, de Bakker JMT, Doevendans PAF, Wittkampf FHM, Loh P, van Es R. Multielectrode Contact Measurement Can Improve Long-Term Outcome of Pulmonary Vein Isolation Using Circular Single-Pulse Electroporation Ablation. Circ Arrhythm Electrophysiol 2022; 15:e010835. [PMID: 35917465 PMCID: PMC9384826 DOI: 10.1161/circep.121.010835] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Irreversible electroporation (IRE) ablation is generally performed with multielectrode catheters. Electrode-tissue contact is an important predictor for the success of pulmonary vein (PV) isolation; however, contact force is difficult to measure with multielectrode ablation catheters. In a preclinical study, we assessed the feasibility of a multielectrode impedance system (MEIS) as a predictor of long-term success of PV isolation. In addition, we present the first-in-human clinical experience with MEIS. METHODS In 10 pigs, one PV was ablated based on impedance (MEIS group), and the other PV was solely based on local electrogram information (electrophysiological group). IRE ablations were performed at 200 J. After 3 months, recurrence of conduction was assessed. Subsequently, in 30 patients undergoing PV isolation with IRE, MEIS was evaluated and MEIS contact values were compared to local electrograms. RESULTS In the porcine study, 43 IRE applications were delivered in 19 PVs. Acutely, no reconnections were observed in either group. After 3 months, 0 versus 3 (P=0.21) PVs showed conduction recurrence in the MEIS and electrophysiological groups, respectively. Results from the clinical study showed a significant linear relation was found between mean MEIS value and bipolar dV/dt (r2=0.49, P<0.001), with a slope of 20.6 mV/s per Ohm. CONCLUSIONS Data from the animal study suggest that MEIS values predict effective IRE applications. For the long-term success of electrical PV isolation with circular IRE applications, no significant difference in efficacy was found between ablation based on the measurement of electrode interface impedance and ablation using the classical electrophysiological approach for determining electrode-tissue contact. Experiences of the first clinical use of MEIS were promising and serve as an important basis for future research.
Collapse
Affiliation(s)
- Marijn H A Groen
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.).,Netherlands Heart Institute, Utrecht (M.H.A.G., P.A.F.D.)
| | - Vincent J H M van Driel
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.).,Department of Cardiology, Haga Teaching Hospital, The Hague, the Netherlands (V.J.H.M.v.D.)
| | - Kars Neven
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.).,Department of Electrophysiology, Alfried Krupp Krankenhaus, Essen (K.N.).,Department of Medicine, Witten/Herdecke University, Witten, Germany (K.N.)
| | - Harry van Wessel
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.).,Abbott Medical Nederland B.V., Veenendaal (H.v.W.)
| | - J M T de Bakker
- Heart Center, Department of Experimental Cardiology, Academic Medical Center Amsterdam, the Netherlands (J.M.T.d.B.)
| | - Pieter A F Doevendans
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.).,Netherlands Heart Institute, Utrecht (M.H.A.G., P.A.F.D.)
| | - Fred H M Wittkampf
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.)
| | - Peter Loh
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.)
| | - René van Es
- Division Heart and Lungs, Department of Cardiology, University Medical Center (M.H.A.G., V.J.H.M.v.D., K.N., H.v.W., P.A.F.D., F.H.M.W., P.L., R.v.E.)
| |
Collapse
|
35
|
Mhanna M, Beran A, Al‐Abdouh A, Sajdeya O, Barbarawi M, Alsaiqali M, Jabri A, Al‐Aaraj A, Alharbi A, Chacko P. Steerable versus nonsteerable sheath technology in atrial fibrillation ablation: A systematic review and meta-analysis. J Arrhythm 2022; 38:570-579. [PMID: 35936032 PMCID: PMC9347204 DOI: 10.1002/joa3.12742] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Revised: 05/18/2022] [Accepted: 05/23/2022] [Indexed: 11/16/2022] Open
Abstract
Introduction Catheter placement and stability are well-known challenges in atrial fibrillation (AF) ablation. As a result, steerable sheaths (SS) were developed to improve catheter stabilization and maintain proper catheter-tissue contact. The purpose of this systematic review and meta-analysis is to see if employing a SS influences procedure outcome. Method We performed a comprehensive literature search for studies that evaluated the efficacy and safety of SS compared to nonsteerable sheaths (NSS) in AF ablation. The primary outcome was the rate of atrial arrhythmia (AA) freedom by the time of the last follow-up. The secondary outcomes were the procedure-related complications and procedural characteristics. Risk ratio (RR) or the mean difference (MD) and corresponding 95% confidence intervals (CIs) were calculated using the random-effects model. Results A total of 10 studies, including 967 AF patients (mean age: 59.2 ± 11.1 years, 516 patients managed with SS vs. 454 with NSS), were included. SS group showed a higher rate of freedom of AA compared to NSS (RR: 1.19; 95% CI 1.09-1.29; p < .001). Both techniques had similar rate for procedural-related complication (RR: 1.09, 95% CI 0.50-2.39; p = .83). The SS strategy had a shorter procedure time (MD -10.6 [min], 95% CI -20.97, -0.20; p = .05) but comparable fluoroscopic and radiofrequency application times to the NSS group. Conclusions The SS for AF catheter ablation not only reduced the total procedure time but also significantly increased the rate of successful ablation while maintaining a similar safety profile when compared to the traditional NSS.
Collapse
Affiliation(s)
- Mohammed Mhanna
- Department of Internal MedicineUniversity of ToledoToledoOhioUSA
| | - Azizullah Beran
- Department of Internal MedicineUniversity of ToledoToledoOhioUSA
| | - Ahmad Al‐Abdouh
- Department of Internal MedicineUniversity of KentuckyLexingtonKentuckyUSA
| | - Omar Sajdeya
- Department of Internal MedicineUniversity of ToledoToledoOhioUSA
| | - Mahmoud Barbarawi
- Department of Cardiovascular MedicineUniversity of ConnecticutFarmingtonConnecticutUSA
| | - Mahmoud Alsaiqali
- Department of Internal MedicineState University of New York Downstate Medical CenterBrooklynNew YorkUSA
| | - Ahmad Jabri
- Department of CardiologyCase Western Reserve University/MetroHealth Medical CenterClevelandOhioUSA
| | - Ahmad Al‐Aaraj
- Department of CardiologyJames Cook University HospitalMiddlesbroughUK
| | | | - Paul Chacko
- Department of Cardiovascular MedicineUniversity of ToledoToledoOhioUSA
| |
Collapse
|
36
|
Orbán G, Salló Z, Perge P, Ábrahám P, Piros K, Nagy KV, Osztheimer I, Merkely B, Gellér L, Szegedi N. Characteristics of Very High-Power, Short-Duration Radiofrequency Applications. Front Cardiovasc Med 2022; 9:941434. [PMID: 35911564 PMCID: PMC9326019 DOI: 10.3389/fcvm.2022.941434] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 06/13/2022] [Indexed: 11/13/2022] Open
Abstract
Introduction Pulmonary vein isolation is the cornerstone of rhythm-control therapy for atrial fibrillation (AF). The very high-power, short-duration (vHPSD) radiofrequency (RF) ablation is a novel technology that favors resistive heating while decreasing the role of conductive heating. Our study aimed to evaluate the correlations between contact force (CF), power, impedance drop (ID), and temperature; and to assess their role in lesion formation with the vHPSD technique. Methods Consecutive patients who underwent initial point-by-point RF catheter ablation for AF were enrolled in the study. The vHPSD ablation was performed applying 90 W for 4 s with an 8 ml/min irrigation rate. Results Data from 85 patients [median age 65 (59–71) years, 34% female] were collected. The median procedure time, left atrial dwelling time, and fluoroscopy time were 70 (60–90) min, 49 (42–58) min, and 7 (5–11) min, respectively. The median RF time was 312 (237-365) sec. No steam pop nor major complications occurred. A total of 6,551 vHPSD RF points were analyzed. The median of CF, maximum temperature, and ID were 14 (10–21) g, 47.6 (45.1–50.4) °C, and 8 (6–10) Ohms, respectively. CF correlated significantly with the maximum temperature (p < 0.0001). A CF of 5 g and above was associated with a significantly higher temperature compared to those lesions with a CF below 5 grams (p < 0.0001). Bilateral first-pass isolation rate was 84%. The 6-month AF-recurrence rate was 7%. Conclusion The maximum temperature and CF significantly correlate with each other during vHPSD applications. A CF ≥ 5 g leads to better tissue heating and thus might be more likely to result in good lesion formation, although this clinical study was unable to assess actual lesion sizes.
Collapse
|
37
|
Saraf K, Black N, Garratt CJ, Muhyaldeen SA, Morris GM. Local impedance-guided ablation and ultra-high density mapping versus conventional or contact force-guided ablation with mapping for treatment of cavotricuspid isthmus dependent atrial flutter. Indian Pacing Electrophysiol J 2022; 22:188-194. [PMID: 35427782 PMCID: PMC9263660 DOI: 10.1016/j.ipej.2022.03.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 03/01/2022] [Accepted: 03/30/2022] [Indexed: 11/13/2022] Open
Abstract
INTRODUCTION - Local impedance (LI) guided ablation as a method of judging lesion effectiveness for cavotricuspid isthmus dependent atrial flutter (CTI-AFL), and ultra-high density (UHD) mapping when breakthrough occurred across an ablation line has not previously been assessed. METHODS This retrospective observational study evaluated patients undergoing CTI-AFL ablation using conventional, contact force (CF) and LI guided strategies. Ablation metrics were collected, and in the LI cohort, the use of UHD mapping for breakthrough evaluated. RESULTS 30 patients were included, 10 per group. Mean total ablation time was significantly shorter with LI (3.2 ± 1.3min) vs conventional (5.6 ± 2.7min) and CF (5.7 ± 2.0min, p = 0.0042). Time from start of ablation to CTI block was numerically shorter with LI (14.2 ± 8.0min) vs conventional and CF (19.7 ± 14.1 and 22.5 ± 19.1min, p = 0.4408). Mean lesion duration was significantly shorter with LI, but there were no differences in the number of lesions required to achieve block, procedural success, complication rates or recurrence. 15/30 patients did not achieve block following first-pass ablation. UHD mapping rapidly identified breakthrough in the five LI patients, including epicardial-endocardial breakthrough (EEB). CONCLUSION - The use of LI during ablation for real-time lesion assessment was as efficacious as the conventional and CF methods. UHD mapping rapidly identified breakthrough, including EEB.
Collapse
Affiliation(s)
- Karan Saraf
- Division of Cardiovascular Sciences, The University of Manchester, Oxford Road, Manchester, M139PL, UK; Manchester Heart Centre, Manchester University NHS Foundation Trust, Oxford Road, Manchester, M139WL, UK
| | - Nicholas Black
- Division of Cardiovascular Sciences, The University of Manchester, Oxford Road, Manchester, M139PL, UK; Royal Oldham Hospital, Rochdale Road, Oldham, OL1 2JH, UK
| | - Clifford J Garratt
- Division of Cardiovascular Sciences, The University of Manchester, Oxford Road, Manchester, M139PL, UK; Manchester Heart Centre, Manchester University NHS Foundation Trust, Oxford Road, Manchester, M139WL, UK
| | - Sahrkaw A Muhyaldeen
- Manchester Heart Centre, Manchester University NHS Foundation Trust, Oxford Road, Manchester, M139WL, UK
| | - Gwilym M Morris
- Division of Cardiovascular Sciences, The University of Manchester, Oxford Road, Manchester, M139PL, UK; Manchester Heart Centre, Manchester University NHS Foundation Trust, Oxford Road, Manchester, M139WL, UK.
| |
Collapse
|
38
|
El Hajjar AH, Mekhael M, Huang C, Noujaim C, Zhang Y, Kholmovski E, Ayoub T, Lim CH, Marrouche N. Predictors of Lesions Contiguity and Transmurality in Canine Ventricular Models After Catheter Ablation. Front Cardiovasc Med 2022; 9:920539. [PMID: 35811729 PMCID: PMC9260253 DOI: 10.3389/fcvm.2022.920539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 05/23/2022] [Indexed: 11/13/2022] Open
Abstract
Background Interlesion gaps and transmurality of lesions after catheter ablation can precipitate suboptimal efficacy in preventing arrhythmias. Aims We aim to assess predictors of acute transmural lesion formation and the interlesion distance threshold for creating a continuous, chronic scar after ventricular ablation. Materials and Methods Ablation procedures were performed on 7 canines followed by late gadolinium enhancement MRI (LGE-MRI). Transmurality of lesions was assessed by 2 independent operators. Ablation parameters such as duration (s), power (W), temperature (C), contact force (CF) (g), were collected for each ablation point. After 7-12 weeks, LGE-MRI was performed, followed by euthanasia, and heart excision. Some lesions were created in pair. Lesion pairs were spaced 7-21 mm apart as measured by Electroanatomic mapping (EAM), with different operating parameters (power 35 or 50W, duration of energy delivery 10, 20 or 30s and contact force of 10g or above). We performed a logistic regression analysis to determine predictors of transmural lesion formation. Results Eighty-one radiofrequency ablation were performed in total [33 in the Left ventricle (LV) and 48 in the Right ventricle (RV)]. Higher CF was a significant predictor of transmural lesion formation (β = 0.15, OR = 1.16, 95% CI [1.03 – 1.3], p = 0.01), and lesions delivered in the RV were more frequently transmural than lesions delivered in the LV (β = −2.43, OR = 0.09, 95%CI [0.02 – 0.34], p < 0.001). For the paired analysis, thirty-eight lesions were created contiguously: fourteen connected lesions and twenty-four unconnected lesions. EAM distance was significantly larger in unconnected lesions than connected lesions (16.17 ± 0.92 mm vs. 11.51 ± 0.68 mm, respectively, p < 0.05). We concluded that an interlesion distance of less than 10 mm is required to prevent gap formation. Average volumes in unconnected lesions (n = 24) at the acute and chronic stages were 0.55 ± 0.11 cm3 and 0.20 ± 0.02 cm3, respectively. On average, lesion volumes were 64% (p < 0.05) smaller at the chronic stage compared to the acute stage. Among connected lesions (n = 14), we observed a volume of 1.19 ± 0.8 cm3 and 0.39 ± 0.15 cm3 at the acute and chronic stages, respectively. These connected lesions reduced in volume by 67% on average. Conclusion To create contiguous scars on the ventricular endocardial surface, paired lesions should be spaced less than ten millimeters apart. Higher contact force should be used in ventricular ablation to create transmural lesions.
Collapse
Affiliation(s)
- Abdel Hadi El Hajjar
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Mario Mekhael
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Chao Huang
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Charbel Noujaim
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Yichi Zhang
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Eugene Kholmovski
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Tarek Ayoub
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Chan Ho Lim
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
| | - Nassir Marrouche
- Department of Cardiology, Tulane Research Innovation for Arrhythmia Discoveries, Tulane University School of Medicine, New Orleans, LA, United States
- *Correspondence: Nassir Marrouche,
| |
Collapse
|
39
|
Rottner L, Moser F, Moser J, Schleberger R, Lemoine M, Münkler P, Dinshaw L, Kirchhof P, Ouyang F, Rillig A, Metzner A, Reissmann B. Revival of the Forgotten. Int Heart J 2022; 63:504-509. [PMID: 35650152 DOI: 10.1536/ihj.21-844] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Pulmonary vein (PV) isolation (PVI) by continuous, transmural and durable lesions is decisive for ensuring long-term freedom from atrial fibrillation (AF). AF ablation requires irrigated tip catheters to reduce thromboembolic complications. This precluded temperature-controlled delivery of radiofrequency (RF) energy.The aim of this study was to evaluate feasibility, acute efficacy, and safety of an irrigated, temperature-controlled ablation catheter [DiamondTemp™ (DT) Medtronic®] for PVI.Consecutive patients with AF underwent PVI using the DT catheter combined with high-power short-duration RF applications. Ablation settings were (1) a catheter tip temperature limit of 60°C, (2) a temperature-controlled power of 50 W, and (3) application duration of 10 seconds. The primary endpoint was acute isolation of PVs, reassessed after a 30-minute waiting period. Secondary endpoints included procedural parameters (defined as a catheter tip temperature of 50°C > 3 seconds, an impedance drop of 5-10 Ω) and the occurrence of serious adverse events.Fifty consecutive patients [mean age 66 ± 12 years, 38 (76%) women, 24 patients with paroxysmal AF (48%)] were included. Median procedure and left atrial dwell time was 89 [68; 107] and 63 [52; 79] minutes, respectively. Mean number of RF applications was 59 ± 20, and mean total RF duration was 14 ± 6 minutes. Acute PVI was achieved in all patients solely using DT ablation. Acute PV reconnection within the waiting period occurred in five patients; all reconnected PVs were successfully reisolated. One major complication occurred.In this study, the DT ablation system demonstrated high acute efficacy for PVI. Temperature-controlled ablation in conjunction with high-power short-duration applications might be effectively supported.
Collapse
Affiliation(s)
- Laura Rottner
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Fabian Moser
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Julia Moser
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Ruben Schleberger
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Marc Lemoine
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Paula Münkler
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Leon Dinshaw
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Paulus Kirchhof
- Department of Cardiology, University Heart and Vascular Center Hamburg.,Institute of Cardiovascular Sciences, University of Birmingham
| | - Feifan Ouyang
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Andreas Rillig
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Andreas Metzner
- Department of Cardiology, University Heart and Vascular Center Hamburg
| | - Bruno Reissmann
- Department of Cardiology, University Heart and Vascular Center Hamburg
| |
Collapse
|
40
|
Venkatesh Prasad K, Bonso A, Woods CE, Goya M, Matsuo S, Padanilam BJ, Kreis I, Yang F, Williams CG, Tranter JH, Verbick LZ, Sarver AE, Almendral J. Lesion Index–guided workflow for the treatment of paroxysmal atrial fibrillation is safe and effective – Final results from the LSI Workflow Study. Heart Rhythm O2 2022; 3:526-535. [PMID: 36340486 PMCID: PMC9626745 DOI: 10.1016/j.hroo.2022.06.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Background Pulmonary vein isolation (PVI) ablation is a standard therapy for paroxysmal atrial fibrillation (PAF). Lesion Index (LSI) is a metric to guide radiofrequency (RF) ablation using the TactiCath Ablation Catheter, Sensor Enabled with the EnSite Cardiac Mapping System (Abbott). Objective This study (NCT-03906461) was designed to capture best practices using LSI-guided catheter ablation to treat PAF subjects in a real-world setting. Methods This prospective single-arm observational study enrolled 143 PAF subjects in the United States, Europe, and Japan undergoing de novo PVI with RF ablation. PVI lesions were assigned to 10 anatomically defined segments. Mean LSIs achieved for all lesions were analyzed. Follow-up was conducted between 3–6 months and 12 months after the procedure. Results Pulmonary veins were isolated in all subjects. The mean achieved LSI was 4.9, with lower values in Europe (4.4) and Japan (4.5) than the United States (5.5). First-pass success, defined as no gaps requiring touch-up ablation after 20 minutes post isolation, was achieved in 76.2% of subjects. Use of high LSI (≥5) resulted in shorter procedure, RF, and fluoroscopy times and fewer touch-up ablations compared to low LSI (<5). At 12 months, 99.3% of subjects were free from procedure- or device-related serious adverse events and 95.7% (112/117) (35.0% on antiarrhythmic drugs) were free from recurrence and/or a repeat ablation procedure for atrial fibrillation / atrial flutter / atrial tachycardia. Conclusion LSI-guided ablation strategies proved safe and effective despite differences in LSI workflows. Use of high LSI values resulted in shorter procedure, RF, and fluoroscopy times and fewer touch-up ablations compared to low LSI.
Collapse
|
41
|
Ronsoni RDM, Silvestrini TL, Saffi MAL, Leiria TLL. Impact of the left common ostium following pulmonary vein isolation in AF: Systematic review and meta-analysis. J Arrhythm 2022; 38:287-298. [PMID: 35785389 PMCID: PMC9237303 DOI: 10.1002/joa3.12710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 03/02/2022] [Accepted: 03/27/2022] [Indexed: 11/19/2022] Open
Abstract
Purpose Pulmonary vein isolation (PVI) through catheter ablation is the basis for the treatment of atrial fibrillation (AF). The left common ostium (LCO) is a high prevalence anatomical variation and has conflicting results in the effects on the prognosis following ablation. We undertook a systematic review and meta-analysis of studies that compared the arrhythmia recurrence rate after radiofrequency ablation or cryoablation balloon between patients with normal pattern pulmonary vein and patients with LCO. Methods and Results Results were pooled using a fixed or random effect, at the discretion of heterogeneity (>25%), in addition, we associated subgroup analysis in these cases and when clinically indicated. Fourteen non-randomized studies totaling 3278 patients were included. In analyses using the two energies all patients: OR 1.01 (95% CI 0.84-1.23; P = .90, I 2 = 67%) and excluding patients with any type of persistent AF (PeAF) and those submitted to linear atrial lesion (LAL) OR 0.80 (95% CI 0.52-1.22; P = .30, I 2 = 71%). Using CRYO: all patients OR 1.34 (95% CI 1.03-1.74; P = .03, I 2 = 0%). Using RF: all patients-OR 0.55 (95% CI 0.32-0.95; P = .03, I 2 = 49%); excluding studies with long duration PeAF and the performance of LAL concomitant-OR 0.45 (95% CI 0.23-0.91; P = .03, I 2 = 44%). Conclusion The results suggest a better prognosis in patients with LCO, submitted to PVI without additional LAL under RF energy in paroxysmal AF and short-duration PeAF. In patients undergoing CRYO, the presence of LCO suggests a worse prognosis.
Collapse
Affiliation(s)
- Rafael de March Ronsoni
- Instituto de Ritmologia CardíacaJoinvilleBrazil
- Universidade da Região de JoinvilleJoinvilleBrazil
| | | | | | - Tiago Luiz Luz Leiria
- Graduate Program in Health Sciences ‐ Instituto de Cardiologia of Rio Grande do Sul/Fundação Universitária de CardiologiaPorto AlegreBrazil
| |
Collapse
|
42
|
Sousa PA, Puga L, Adão L, Primo J, Khoueiry Z, Lebreiro A, Fonseca P, Lagrange P, Elvas L, Gonçalves L. Two years after pulmonary vein isolation guided by ablation index-a multicenter study. J Arrhythm 2022; 38:346-352. [PMID: 35785367 PMCID: PMC9237314 DOI: 10.1002/joa3.12696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Revised: 03/05/2022] [Accepted: 03/07/2022] [Indexed: 11/08/2022] Open
Abstract
Background The use of the Ablation Index (AI) software for paroxysmal atrial fibrillation (AF) has been associated with higher acute effectiveness and higher 1-year arrhythmia freedom. There is, however, a lack of data concerning longer follow-up. We aim to evaluate the 2-year outcomes after a standardized AI-guided pulmonary vein isolation (PVI). Methods Prospective, multicenter study of consecutive patients referred for paroxysmal AF ablation from January 2018 to July 2019. PVI was guided by a tailored AI value (≥500 for anterior segment, ≥450 for the roof segments and inferior segments, and 400 for the posterior wall) and an ILD ≤6 mm. The primary endpoints were acute and long-term effectiveness. Results The study included 218 (842 PV) patients (61% males, median age of 60 [IQR 49-68] years) with paroxysmal AF. First-pass isolation was obtained in 93% of the patients, with an acute reconnection occurring in 10.6% of the patients (3.2% of the PV) following adenosine trial. After a median follow-up of 26 (IQR 20-30) months, freedom from any documented atrial arrhythmia was 83.4%, off-AAD. The rate of adverse events was 1.4%. Although procedural parameters differ across centers (p < 0.001), the acute (p = 0.56) and long-term effectiveness (p = 0.83) were consistent between centers. Conclusions Patients with paroxysmal AF submitted to an AI-guided PVI workflow presented high arrhythmia freedom at 2-years of follow-up.
Collapse
Affiliation(s)
- Pedro A. Sousa
- Pacing & Electrophysiology Unit, Cardiology DepartmentCoimbra's Hospital and University CenterCoimbraPortugal
| | - Luís Puga
- Pacing & Electrophysiology Unit, Cardiology DepartmentCoimbra's Hospital and University CenterCoimbraPortugal
| | - Luís Adão
- Cardiology DepartmentUniversity Hospital Center of São JoãoPortoPortugal
| | - João Primo
- Cardiology DepartmentVila Nova de Gaia & Espinho Hospital CenterPortugal
| | - Ziad Khoueiry
- Cardiology DepartmentClinique Saint PierrePerpignanFrance
| | - Ana Lebreiro
- Cardiology DepartmentUniversity Hospital Center of São JoãoPortoPortugal
| | - Paulo Fonseca
- Cardiology DepartmentVila Nova de Gaia & Espinho Hospital CenterPortugal
| | | | - Luís Elvas
- Pacing & Electrophysiology Unit, Cardiology DepartmentCoimbra's Hospital and University CenterCoimbraPortugal
| | - Lino Gonçalves
- Pacing & Electrophysiology Unit, Cardiology DepartmentCoimbra's Hospital and University CenterCoimbraPortugal
- ICBR, Faculty of MedicineUniversity of CoimbraCoimbraPortugal
| |
Collapse
|
43
|
Pothineni NVK, Cherian TS, Daw JM, Zado ES, Marchlinski FE. Temporal Changes in Pulmonary Vein Reconnection During Repeat Catheter Ablation for Early Recurrence of Atrial Fibrillation. JACC Clin Electrophysiol 2022; 8:1046-1048. [PMID: 35643808 DOI: 10.1016/j.jacep.2022.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 03/07/2022] [Accepted: 03/13/2022] [Indexed: 10/18/2022]
|
44
|
Backhoff D, Müller MJ, Betz T, Arnold A, Schneider H, Paul T, Krause U. Contact Force Guided Radiofrequency Current Application at Developing Myocardium: Summary and Conclusions. J Cardiovasc Electrophysiol 2022; 33:1757-1766. [PMID: 35578015 DOI: 10.1111/jce.15544] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2022] [Revised: 03/20/2022] [Accepted: 03/27/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND Catheter contact is one key determinant for lesion size in radiofrequency catheter ablation (RFA). Monitoring of contact force (CF) during RFA has been shown to improve efficacy of RFA in experimental settings as well as in adult patients. Coronary artery narrowing after RFA has been described in experimental settings as well as in children and adults and may be dependent from catheter contact. Value of CF monitoring concerning these issues has not been systematically yet. OBJECTIVE Value of high versus low CF during RFA in piglets was studied to assess lesion size and potential coronary artery involvement mimicking RFA in small children. ANIMALS AND METHODS RFA with continuous CF monitoring was performed in 24 piglets (median weight 18.5 kg) using a 7F TactiCath Quartz RF ablation catheter (Abbott, Illinois, USA). A total of 7 lesions were induced in each animal applying low (10-20 g) or high (40-60 g) CF. RF energy was delivered with a target temperature of 65 °C at 30 W for 30 seconds. Coronary angiography was performed prior and immediately after RF application. Animals were assigned to repeat coronary angiography followed by heart removal after 48 h (n=12) or 6 months (n=12). Lesions with surrounding myocardium were excised, fixated and stained. Lesion volumes were measured by microscopic planimetry. RESULTS A total of 148 RF lesions were identified in the explanted hearts. Only in the subset of lesions at the AV annulus 6 month after ablation, lesion size and number of lesions exhibiting transmural extension were higher in the high CF group compared to low CF. In all other locations CF had no impact on lesion size and mural extension after 48 h as well as after 6 months. Additional parameters as Lesion Size Index and Force Time Integral were also not related to lesion size. Coronary artery damage was present in 2 animals after 48 h and in 1 after 6 months and was not related to CF. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- David Backhoff
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| | - Matthias J Müller
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| | - Teresa Betz
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| | - Andreas Arnold
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| | - Heike Schneider
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| | - Thomas Paul
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| | - Ulrich Krause
- Department of Pediatric Cardiology and Intensive Care Medicine, Georg August University Medical Center, Göttingen, Germany
| |
Collapse
|
45
|
Local Impedance Drop Predicts Durable Conduction Block in Patients With Paroxysmal Atrial Fibrillation. JACC Clin Electrophysiol 2022; 8:595-604. [PMID: 35589172 DOI: 10.1016/j.jacep.2022.01.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 01/03/2022] [Accepted: 01/05/2022] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This analysis was performed to evaluate the transition of local impedance (LI) drop during pulmonary vein isolation (PVI) to durable block and mature lesion formation based on 3-month mapping procedures. BACKGROUND A radiofrequency catheter measuring LI has been shown to be effective for performing PVI in patients with paroxysmal atrial fibrillation. Previous analysis has demonstrated LI drop to be predictive of pulmonary vein segment conduction block during an atrial fibrillation ablation procedure. METHODS Fifty-eight patients who had undergone LI-blinded de novo PVI returned for a 3-month mapping procedure. PVI ablation circles were divided into 16 anatomic segments for classification (durable block or gap), and the median LI drop within segments with an interlesion distance of ≤6 mm was compared. A total of 51 data sets met the criteria for segmental analysis of LI performance. RESULTS At the 3-month procedure, PV connection was confirmed in at least 1 PV segment in 35 of the included patients. LI drop outperformed generator impedance drop as a predictor of durable conduction block (area under the receiver-operating characteristic curve: 0.79 vs 0.68; P = 0.003). Optimal LI drops were identified by left atrial region (anterior/superior: 16.9 Ω [sensitivity: 69.1%; specificity: 85.0%; positive predictive value for durable conduction block: 97.7%]; posterior/inferior:14.2 Ω [sensitivity: 73.8%; specificity: 78.3%; positive predictive value: 96.9%]). Starting LI before radiofrequency (RF) application was significantly different among healthy, gap, and mature scar tissue and was also a contributing factor to achieving an optimal LI drop (85.2% of RF applications with a starting LI of ≥110 Ω achieved the optimal regional drop or greater). CONCLUSIONS LI drop is predictive of durable PV segment isolation. Preablation starting LI is associated with the magnitude of LI drop. These findings suggest that a regional approach to RF ablation guided by LI combined with careful interlesion distance control may be beneficial in patients with paroxysmal atrial fibrillation (Electrical Coupling Information From the Rhythmia HDx System and DirectSense Technology in Subjects With Paroxysmal Atrial Fibrillation [LOCALIZE]; NCT03232645).
Collapse
|
46
|
Sousa PA, Puga L, Barra S, Campos D, António N, Elvas L, Gonçalves L. High-sensitivity Troponin I and Ablation Effectiveness Quotient after Ablation Index-guided pulmonary vein isolation-markers of arrhythmia recurrence? J Interv Card Electrophysiol 2022; 65:115-121. [PMID: 35469051 DOI: 10.1007/s10840-022-01229-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Accepted: 04/18/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND There are conflicting data regarding the relationship between high-sensitivity cardiac Troponin I (Hs-cTnI) and the ablation effectiveness quotient (AEQ) with arrhythmia recurrence following atrial fibrillation (AF) ablation. Our goals were to evaluate the impact of the Ablation Index (AI) software on Hs-cTnI and AEQ levels and to assess whether these markers are predictors of arrhythmia recurrence. METHODS Prospective single-center study of 75 consecutive patients referred for paroxysmal AF ablation from October 2017 to January 2019. Procedural endpoints and 2-year outcomes were assessed and compared to those of 75 propensity score-matched patients submitted to non-AI-guided pulmonary vein isolation (PVI) [control group]. RESULTS Compared to the control group, patients having AI-guided PVI had lower Hs-cTnI values (1580 [IQR 1180-2140] ng/L vs. 2600 [IQR 1840 - 3900], p < 0.001) and a lower AEQ (0.9 [IQR 0.6-1.2] ng/L/s vs. 1.4 [0.8-1.6] ng/L/s, p < 0.001). After a median follow-up of 26 (IQR 20-32) months, there was a significant reduction in arrhythmia recurrence in the AI group (15% vs. 31%, HR 0.67 [95% CI, 0.32-1.40], p = 0.02). However, neither Hs-cTnI nor AEQ was predictors of arrhythmia recurrence in AI-guided PVI. CONCLUSIONS The use of the AI software led to reduced levels of Hs-cTnI and lower AEQ in AF patients submitted to PVI. However, none of these markers predicted arrhythmia recurrence.
Collapse
Affiliation(s)
- Pedro A Sousa
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Morada: Praceta Prof Mota Pinto, 3000-075, Coimbra, Portugal.
| | - Luís Puga
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Morada: Praceta Prof Mota Pinto, 3000-075, Coimbra, Portugal
| | - Sérgio Barra
- Cardiology Department, Hospital da Luz Arrábida, V. N. Gaia, Portugal
| | - Diana Campos
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Morada: Praceta Prof Mota Pinto, 3000-075, Coimbra, Portugal
| | - Natália António
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Morada: Praceta Prof Mota Pinto, 3000-075, Coimbra, Portugal.,Faculty of Medicine, ICBR, University of Coimbra, Coimbra, Portugal
| | - Luís Elvas
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Morada: Praceta Prof Mota Pinto, 3000-075, Coimbra, Portugal
| | - Lino Gonçalves
- Pacing & Electrophysiology Unit, Cardiology Department, Coimbra's Hospital and University Center, Morada: Praceta Prof Mota Pinto, 3000-075, Coimbra, Portugal.,Faculty of Medicine, ICBR, University of Coimbra, Coimbra, Portugal
| |
Collapse
|
47
|
Comparison of outcomes with low-power long duration versus high-power short duration of ablation: the role of the acute change in sinus rhythm after the ablation as a predictor of long-term success. Heart Vessels 2022; 37:1749-1756. [DOI: 10.1007/s00380-022-02066-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 03/25/2022] [Indexed: 11/04/2022]
|
48
|
Yang G, Zheng L, Jiang C, Fan J, Liu X, Zhan X, Li J, Wang L, Yang H, Zhu W, Du H, Ma G, Ma W, Kojodjojo P, Chen M. Circumferential Pulmonary Vein Isolation Plus Low-Voltage Area Modification in Persistent Atrial Fibrillation. JACC Clin Electrophysiol 2022; 8:882-891. [DOI: 10.1016/j.jacep.2022.03.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Revised: 03/18/2022] [Accepted: 03/23/2022] [Indexed: 11/25/2022]
|
49
|
Asvestas D, Sousonis V, Kotsovolis G, Karanikas S, Xintarakou A, Sakadakis E, Rigopoulos AG, Kalogeropoulos AS, Vardas P, Tzeis S. Cavotricuspid isthmus ablation guided by force-time integral - A randomized study. Clin Cardiol 2022; 45:503-508. [PMID: 35301726 PMCID: PMC9045076 DOI: 10.1002/clc.23805] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 02/13/2022] [Accepted: 02/17/2022] [Indexed: 11/17/2022] Open
Abstract
Background Force‐time integral (FTI) is an ablation marker of lesion quality and transmurality. A target FTI of 400 gram‐seconds (gs) has been shown to improve durability of pulmonary vein isolation, following atrial fibrillation ablation. However, relevant targets for cavotricuspid isthmus (CTI) ablation are lacking. Hypothesis We sought to investigate whether CTI ablation with 600 gs FTI lesions is associated with reduced rate of transisthmus conduction recovery compared to 400 gs lesions. Methods Fifty patients with CTI‐dependent flutter were randomized to ablation using 400 gs (FTI400 group, n = 26) or 600 gs FTI lesions (FTI600 group, n = 24). The study endpoint was spontaneous or adenosine‐mediated recovery of transisthmus conduction, after a 20‐min waiting period. Results The study endpoint occurred in five patients (19.2%) in group FTI400 and in four patients (16.7%) in group FTI600, p = .81. First‐pass CTI block was similar in both groups (50% in FTI400 vs. 54.2% in FTI600, p = .77). There were no differences in the total number of lesions, total ablation time, procedure time and fluoroscopy duration between the two groups. There were no major complications in any group. In the total population, patients not achieving first‐pass CTI block had significantly higher rate of acute CTI conduction recovery, compared to those with first‐pass block (29.2% vs. 7.7% respectively, p = .048). Conclusions CTI ablation using 600 gs FTI lesions is not associated with reduced spontaneous or adenosine‐mediated recurrence of transisthmus conduction, compared to 400 gs lesions.
Collapse
Affiliation(s)
| | | | - George Kotsovolis
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| | - Stavros Karanikas
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| | | | | | | | | | - Panos Vardas
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| | - Stylianos Tzeis
- Department of Cardiology, Mitera Hospital, Hygeia Group, Athens, Greece
| |
Collapse
|
50
|
Themistoclakis S, Calzolari V, De Mattia L, China P, Russo AD, Fassini G, Casella M, Caporaso I, Indiani S, Addis A, Basso C, Della Barbera M, Thiene G, Tondo C. In vivo Lesion Index (LSI) validation in percutaneous radiofrequency catheter ablation. J Cardiovasc Electrophysiol 2022; 33:874-882. [PMID: 35262242 DOI: 10.1111/jce.15442] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 01/06/2022] [Accepted: 01/30/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Lesion Index (LSI) has been developed to predict lesion efficacy during radiofrequency (RF) catheter ablation. However, its value in predicting lesions size has still to be established. The aim of our study was to assess the lesions size reproducibility for pre-specified values of LSI reached during RF delivery in an in vivo beating heart. METHODS Ablation lesions were created with different values of LSI in 7 domestic pigs by means of a contact force sensing catheter (TactiCathTM , Abbott). Lesions were identified during RF delivery by means of a 3D mapping system (EnSiteTM Precision, Abbott) and measured after heart explantation. Histology was carried out after gross examination on the first 3 lesions to confirm the accuracy of the macroscopic evaluation. RESULTS A total of 64 myocardial lesions were created. Thirty-nine lesions were excluded from the analysis for the following reasons: histological confirmation of macroscopic lesion measurement (n=3), transmurality (n=24), unfavorable anatomic position (n=10), not macroscopically identifiable (n=2). In a final set of 25 non-transmural lesions, injury width and depth were respectively 4.6±0.6 mm and 2.6±0.8 mm for LSI=4, 7.3±0.8 mm and 4.7±0.6 mm for LSI=5, and 8.6±1.2 mm and 7.2±1.1 mm for LSI=6. A strong linear correlation was observed between LSI and lesion width (r=0.87, p<0.00001) and depth (r=0.89, p<0.00001). Multiple linear regression analysis identified LSI as the only ablation parameter that significantly predicted lesion width (p<0.001) and depth (p<0.001). CONCLUSION In our in vivo study, LSI proved highly predictive of lesion size and depth. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | | | - Luca De Mattia
- Ospedale Ca'Foncello-ULSS2 Marca Trevigiana, Treviso, Italy
| | - Paolo China
- Ospedale dell'Angelo-ULSS3 Serenissima, Mestre-Venice, Italy
| | | | - Gaetano Fassini
- Heart Rhythm Center, Monzino Cardiac Center, IRCCS, Milan, Italy
| | - Michela Casella
- Heart Rhythm Center, Monzino Cardiac Center, IRCCS, Milan, Italy
| | - Igor Caporaso
- Abbott Medical Italia S.p.A., Sesto San Giovanni, Italy
| | | | - Alessandro Addis
- CRABCC, Biotechnology Research Center for Cardiothoracic Applications, Rivolta D'Adda, Italy
| | - Cristina Basso
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Mila Della Barbera
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Gaetano Thiene
- Cardiovascular Pathology, Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Claudio Tondo
- Heart Rhythm Center, Monzino Cardiac Center, IRCCS, Milan, Italy.,Department of Clinical Sciences and Community Health, University of Milan, Milan, Italy
| |
Collapse
|