1
|
Muensterer OJ. Magnets in Paediatric Surgery. J Pediatr Surg 2025; 60:162042. [PMID: 39489680 DOI: 10.1016/j.jpedsurg.2024.162042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/20/2024] [Accepted: 10/21/2024] [Indexed: 11/05/2024]
Abstract
Magnetism, recognized in ancient Greece and China, is a fundamental physical force influencing numerous domains, including medicine and surgery. Historically, the medical use of magnets dates back over two millennia. As proof, the ancient Sanskrit medical textbook Sushruta Samhita describes the removal of a metallic arrow lodged in the flesh with a magnet. Modern uses span from diagnostic to therapeutic applications, including in paediatric surgery. High-field magnetism, utilized in Magnetic Resonance Imaging and Transcranial Magnetic Stimulation (TMS), shows promise for various medical conditions, including depression and neurodegenerative diseases. Despite controversy surrounding low-field magnetism, its potential remains a topic of interest. One of the applications in paediatric surgery that has been evaluated in a randomized controlled trial is magnetic acupuncture for supplementary treatment of postoperative pain. As most paediatric surgeons are well aware, the use of magnets also poses risks, particularly in children, where ingested magnets can cause severe gastrointestinal complications. Regulations have tightened in response to increasing cases of magnet ingestion-related injuries but more needs to be done to avoid injury. Currently, magnets play crucial roles in a variety of medical applications, including magnetic cell sorting and therapeutic devices. Notably, magnetic compression anastomosis, which uses magnets to facilitate luminal tissue joining, have seen significant advancements. Innovations include devices for oesophageal atresia repair, with recent studies showing promising results in animal models and early clinical trials. Future research should focus on optimizing magnetic devices, expanding their applications, and ensuring safety. The continued exploration of magnetism's effects on living tissues and the development of new magnetic technologies could revolutionize medical and surgical practices, particularly in paediatric care.
Collapse
Affiliation(s)
- Oliver J Muensterer
- Department of Paediatric Surgery, Dr. von Hauner Children's Hospital, LMU University Hospital, Lindwurmstrasse 4, 80337 Munich, Germany.
| |
Collapse
|
2
|
Hall A, Emil S, Elhafid M, Guadagno E, Kattini C, Keijzer R, Klapman S, Laberge JM, Livingston M, Puligandla P, Nasr A, Snarr P, Youssef F, Zani A. The Canadian Experience With Magnetic Esophageal Anastomosis: A Report From the Canadian Consortium for Research in Pediatric Surgery Study (CanCORPS). J Pediatr Surg 2025:162150. [PMID: 39824744 DOI: 10.1016/j.jpedsurg.2024.162150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/30/2024] [Revised: 12/04/2024] [Accepted: 12/30/2024] [Indexed: 01/20/2025]
Abstract
OBJECTIVE Magnetic anastomosis is an innovative technique for establishing esophageal continuity in infants born with esophageal atresia. Few case series featuring this technology have been published, with even fewer reports on complications. We present the entire Canadian experience with this approach. METHODS A nationwide retrospective review of all esophageal atresia patients treated with magnetic anastomoses in Canada was conducted through the Canadian Consortium for Research in Pediatric Surgery (CanCORPS). RESULTS Magnetic anastomoses were attempted in nine patients including four Type A, two Type B, and three Type C. The median pre-operative esophageal gap was 2.9 cm (range 0.0-5.5 cm). In four patients, magnetic anastomosis was used as a salvage technique, after failed attempted primary repair. Seven patients (78 %) achieved esophageal patency after magnet insertion. Strictures developed in all successful cases and required a median of 10 dilatations (range 3-16). In one patient with a failed anastomosis, the proximal magnet perforated the proximal esophageal pouch, while in the second case, the magnets failed to couple together. One patient had an anastomosis form but required operative intervention shortly afterwards to both revise the anastomosis and address a missed proximal fistula. CONCLUSION In the Canadian experience, magnetic anastomosis was successful in establishing esophageal continuity in most patients. However, all patients developed strictures requiring multiple dilatations, and there was a substantial risk of complications requiring additional operative procedures. Further refinement of this technique may establish magnetic anastomosis as another tool for the pediatric surgeon treating long-gap and other challenging cases of esophageal atresia.
Collapse
Affiliation(s)
- Amanda Hall
- Jim Pattison Children's Hospital, 103 Hospital Drive, Saskatoon, Saskatchewan S7N 0W8, Canada.
| | - Sherif Emil
- Harvey E. Beardmore Division of Pediatric Surgery, The Montreal Children's Hospital, McGill University Health Centre, 1001 Db Decarie, Montreal, Quebec H4A 3J1, Canada.
| | - Melanie Elhafid
- Jim Pattison Children's Hospital, 103 Hospital Drive, Saskatoon, Saskatchewan S7N 0W8, Canada.
| | - Elena Guadagno
- Harvey E. Beardmore Division of Pediatric Surgery, The Montreal Children's Hospital, McGill University Health Centre, 1001 Db Decarie, Montreal, Quebec H4A 3J1, Canada.
| | - Cesar Kattini
- The Children's Hospital of Eastern Ontario, 401 Smyth Rd, Ottawa, Ontario K1H 8L1, Canada.
| | - Richard Keijzer
- The Children's Hospital of Winnipeg, 840 Sherbrook St, Winnipeg, Manitoba R3E 0Z3, Canada.
| | - Sarah Klapman
- McMaster Children's Hospital, 1200 Main St, West Hamilton, Ontario L8N 3Z5, Canada.
| | - Jean-Martin Laberge
- Harvey E. Beardmore Division of Pediatric Surgery, The Montreal Children's Hospital, McGill University Health Centre, 1001 Db Decarie, Montreal, Quebec H4A 3J1, Canada.
| | - Michael Livingston
- McMaster Children's Hospital, 1200 Main St, West Hamilton, Ontario L8N 3Z5, Canada.
| | - Pramod Puligandla
- Harvey E. Beardmore Division of Pediatric Surgery, The Montreal Children's Hospital, McGill University Health Centre, 1001 Db Decarie, Montreal, Quebec H4A 3J1, Canada.
| | - Ahmed Nasr
- The Children's Hospital of Eastern Ontario, 401 Smyth Rd, Ottawa, Ontario K1H 8L1, Canada.
| | - Phillip Snarr
- The Children's Hospital of Winnipeg, 840 Sherbrook St, Winnipeg, Manitoba R3E 0Z3, Canada.
| | - Fouad Youssef
- The Children's Hospital of Winnipeg, 840 Sherbrook St, Winnipeg, Manitoba R3E 0Z3, Canada.
| | - Augusto Zani
- The Hospital for Sick Children, Toronto, Ontario, Canada.
| |
Collapse
|
3
|
Zhang MM, Sha HC, Xue HR, Qin YF, Song XG, Li Y, Li Y, Deng ZW, Gao YL, Dong FF, Lyu Y, Yan XP. Novel magnetic compression technique for the treatment of postoperative anastomotic stenosis in rectal cancer: A case report. World J Gastrointest Surg 2024; 16:1926-1932. [PMID: 38983326 PMCID: PMC11230028 DOI: 10.4240/wjgs.v16.i6.1926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/11/2024] [Accepted: 04/22/2024] [Indexed: 06/27/2024] Open
Abstract
BACKGROUND The treatment of postoperative anastomotic stenosis after excision of rectal cancer is challenging. Endoscopic balloon dilation and radial incision are not effective in all patients. We present a new endoscopy-assisted magnetic compression technique (MCT) for the treatment of rectal anastomotic stenosis. We successfully applied this MCT to a patient who developed an anastomotic stricture after radical resection of rectal cancer. CASE SUMMARY A 50-year-old man had undergone laparoscopic radical rectal cancer surgery at a local hospital 5 months ago. A colonoscopy performed 2 months ago indicated that the rectal anastomosis was narrow due to which ileostomy closure could not be performed. The patient came to the Magnetic Surgery Clinic of the First Affiliated Hospital of Xi'an Jiaotong University after learning that we had successfully treated patients with colorectal stenosis using MCT. We performed endoscopy-assisted magnetic compression surgery for rectal stenosis. The magnets were removed 16 d later. A follow-up colonoscopy performed after 4 months showed good anastomotic patency, following which, ileostomy closure surgery was performed. CONCLUSION MCT is a simple, non-invasive technique for the treatment of anastomotic stricture after radical resection of rectal cancer. The technique can be widely used in clinical settings.
Collapse
Affiliation(s)
- Miao-Miao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
- Department of Shaanxi Provincial Key Laboratory of Magnetic Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- Department of National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Huan-Chen Sha
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Hai-Rong Xue
- Department of Gastroenterology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Yuan-Fa Qin
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Xiao-Gang Song
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Yun Li
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Yu Li
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Zheng-Wu Deng
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Yu-Lin Gao
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Fang-Fang Dong
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
- Department of Shaanxi Provincial Key Laboratory of Magnetic Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- Department of National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Xiao-Peng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
- Department of Shaanxi Provincial Key Laboratory of Magnetic Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- Department of National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| |
Collapse
|
4
|
Zhang M, Mao J, Xue K, Zhang Y, Ma J, Li Y, Lyu Y, Yan X. A Novel Deformable Self-Assembled Magnetic Anastomosis Ring (DSAMAR) for Esophageal Stenosis Recanalization without Temporary Gastrostomy in Beagle Dogs. J Pediatr Surg 2024; 59:1204-1209. [PMID: 37968150 DOI: 10.1016/j.jpedsurg.2023.10.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 09/28/2023] [Accepted: 10/14/2023] [Indexed: 11/17/2023]
Abstract
BACKGROUND To assess the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR) in the treatment of esophageal stenosis in beagle dogs via transoral access without temporary gastrostomy. METHODS Experimental esophageal stenosis was created in 10 beagle dogs by partial cervical esophageal ligation. The DSAMAR was inserted into the distal esophagus via the narrow section of the esophagus using a gastroscope. A circular DSAMAR was placed in the proximal esophagus. The magnetic rings on both sides of the experimental stenosis automatically attracted each other. We then recorded the operation time, postoperative complications, anastomotic formation time, and magnetic ring discharge time. The dogs were euthanized 4 weeks postoperatively; subsequently, we obtained the esophageal anastomotic specimens and observed the anastomotic formation via the naked eye and by light microscopy. RESULTS Our esophageal stenosis model produced reproducible stenoses in all dogs, which was confirmed via endoscopy and esophagography. DSAMAR was successfully implanted in all experimental animals under endoscopic and X-ray monitoring, and all linear DSAMARs were successfully transformed into rings. The magnets at both ends of the esophageal stenosis were automatically attracted. All animals survived until euthanasia. No complications, including esophageal perforation, bleeding, and gastrointestinal obstruction, were noted during the perioperative period. The mean operation time of endoscopic magnetic anastomosis was 15.6 ± 2.41 (range, 12-19) min. The mean esophageal anastomotic formation time was 8.8 ± 1.03 (range, 7-10) days, and the mean expulsion time of DSAMAR was 13.94 ± 2.88 (range, 10-19) days. Gastroscopy and esophagography were performed at 4 weeks postoperatively; the esophageal patency was good. Macroscopic observation of the esophageal anastomotic specimens revealed that the esophageal mucosal layer of the anastomosis had good continuity and the anastomosis was smooth. CONCLUSION DSAMAR is a feasible option for magnetic recanalization of esophageal stricture via transoral access without temporary gastrostomy.
Collapse
Affiliation(s)
- Miaomiao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China
| | - Jianqi Mao
- Zonglian College, Xi'an Jiaotong University, Xi'an, China
| | - Kaihua Xue
- Department of Urology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Yuhan Zhang
- Qide College, Xi'an Jiaotong University, Xi'an, China
| | - Jia Ma
- Department of Surgical Oncology, Shaanxi Provincial People's Hospital, Xi'an, China
| | - Yu Li
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China.
| | - Xiaopeng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, Xi'an, China.
| |
Collapse
|
5
|
Tian BY, Zhang MM, Ma J, Lyu Y, Yan XP. Influence of different magnetic forces on the effect of colonic anastomosis in rats. World J Gastrointest Surg 2024; 16:860-870. [PMID: 38577092 PMCID: PMC10989341 DOI: 10.4240/wjgs.v16.i3.860] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 01/18/2024] [Accepted: 02/06/2024] [Indexed: 03/22/2024] Open
Abstract
BACKGROUND Despite much work having been conducted on magnetic compression anastomosis (MCA) in the digestive tract, there are no reports on the influence of magnetic force on the anastomosis. AIM To investigate the effect of different magnetic force magnets on the MCA of the digestive tract. METHODS Two groups of magnets of the same sizes but different magnetic forces were designed and produced. A total of 24 Sprague-Dawley rats were randomly assigned into two groups (powerful magnet group and common magnet group), with 12 rats in each group. Two types of magnets were used to complete the colonic side-to-side anastomosis of the rats. The operation time and magnet discharge time were recorded. The anastomotic specimens were obtained 4 wk after the operation and then the burst pressure and diameter of the anastomosis were measured, and the anastomosis was observed via the naked eye and subjected to histological examination. RESULTS The magnetic forces of the powerful and common magnet groups at zero distance were 8.26 N and 4.10 N, respectively. The colonic side-to-side anastomosis was completed in all 24 rats, and the operation success rate and postoperative survival rate were 100%. No significant difference was noted in the operation time between the two groups. The magnet discharge time of the powerful magnet group was slightly longer than that of the common magnet group, but the difference was not statistically significant (P = 0.513). Furthermore, there was no statistical difference in the burst pressure (P = 0.266) or diameter of magnetic anastomosis (P = 0.095) between the two groups. The gross specimens of the two groups showed good anastomotic healing, and histological observation indicated good mucosal continuity without differences on healing. CONCLUSION In the rat colonic side-to-side MCA model, both the powerful magnet with 8.26 N and the common magnet with 4.10 N showed no significant impact on the anastomosis establishment process or its effect.
Collapse
Affiliation(s)
- Bo-Yan Tian
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Miao-Miao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Jia Ma
- Department of Surgical Oncology, Shaanxi Provincial People's Hospital, Xi'an 710068, Shaanxi Province, China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Xiao-Peng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| |
Collapse
|
6
|
Lee WG, Evans LL, Chen CS, Fuchs JR, Zamora IJ, Bruzoni M, Harrison MR, Muensterer OJ. Lessons Learned From the First-In-Human Compassionate Use of Connect-EA™ in Ten Patients With Esophageal Atresia. J Pediatr Surg 2024; 59:437-444. [PMID: 37838619 DOI: 10.1016/j.jpedsurg.2023.09.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 09/12/2023] [Accepted: 09/15/2023] [Indexed: 10/16/2023]
Abstract
INTRODUCTION Delayed primary repair of esophageal atresia in patients with high-risk physiologic and anatomic comorbidities remains a daunting challenge with an increased risk for peri-operative morbidity and mortality via conventional repair. The Connect-EA device facilitates the endoscopic creation of a secure esophageal anastomosis. This follow-up study reports our long-term outcomes with the novel esophageal magnetic compression anastomosis (EMCA) Connect-EA device for EA repair, as well as lessons learned from the ten first-in-human cases. We propose an algorithm to maximize the advantages of the device for EA repair. METHODS Under compassionate use approval, from June 2019 to December 2022, ten patients with prohibitive surgical or medical risk factors underwent attempted EMCA with this device. All patients underwent prior gastrostomy, tracheoesophageal fistula ligation (if necessary), and demonstrated pouch apposition prior to EMCA. RESULTS Successful device deployment and EMCA formation were achieved in nine patients (90%). Mean time to anastomosis formation was 8 days (range 5-14) and the device was retrieved endoscopically in five (56%) cases. At median follow-up of 22 months (range 4-45), seven patients (78%) are tolerating oral nutrition. Balloon dilations (median 4, range 1-11) were performed either prophylactically for radiographic asymptomatic anastomotic narrowing (n = 7, 78%) or to treat clinically-significant anastomotic narrowing (n = 2, 22%) with no ongoing dilations at 3-month follow up post-repair. CONCLUSION EMCA with the Connect-EA device is a safe and feasible minimally-invasive alterative for EA repair in high-risk surgical patients. Promising post-operative outcomes warrant further Phase I investigation. LEVEL OF EVIDENCE IV, Case series of novel operative technique without comparison group.
Collapse
Affiliation(s)
- William G Lee
- Department of Pediatric Surgery, University of California San Francisco, 550 16th Street Box 0570, San Francisco, CA 94143, USA
| | - Lauren L Evans
- Department of Pediatric Surgery, University of California San Francisco, 550 16th Street Box 0570, San Francisco, CA 94143, USA
| | - Caressa S Chen
- Department of Pediatric Surgery, University of California San Francisco, 550 16th Street Box 0570, San Francisco, CA 94143, USA
| | - Julie R Fuchs
- Division of Pediatric Surgery, Stanford University School of Medicine, 453 Quarry Road, Palo Alto, CA 94304, USA
| | - Irving J Zamora
- Department of Pediatric Surgery, Monroe Carell Jr Children's Hospital at Vanderbilt, 2200 Children's Way 7th Floor, Nashville, TN 37232, USA
| | - Matias Bruzoni
- Division of Pediatric Surgery, Stanford University School of Medicine, 453 Quarry Road, Palo Alto, CA 94304, USA
| | - Michael R Harrison
- Department of Pediatric Surgery, University of California San Francisco, 550 16th Street Box 0570, San Francisco, CA 94143, USA
| | - Oliver J Muensterer
- Department of Pediatric Surgery, Dr. von Hauner Children's Hospital, LMU Munich, Lindwurmstrasse 4, 80337, Munich, Germany.
| |
Collapse
|
7
|
Zhang MM, Sha HC, Qin YF, Lyu Y, Yan XP. Y-Z deformable magnetic ring for the treatment of rectal stricture: A case report and review of literature. World J Gastroenterol 2024; 30:599-606. [PMID: 38463020 PMCID: PMC10921145 DOI: 10.3748/wjg.v30.i6.599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 12/18/2023] [Accepted: 01/16/2024] [Indexed: 02/05/2024] Open
Abstract
BACKGROUND Treatment of postoperative anastomotic stenosis for colorectal cancer is often challenging, especially for patients who do not respond well to endoscopy. In cases where patients have undergone an enterostomy, the stenosis can be easily resolved through magnetic compression. However, common magnetic compression techniques cannot be performed on those without enterostomy. We designed a novel Y-Z deformable magnetic ring (Y-Z DMR) and successfully applied it to a patient with a stenosis rectal anastomosis and without enterostomy after rectal cancer surgery. CASE SUMMARY We here report the case of a 57-year-old woman who had undergone a laparoscopic radical rectum resection (Dixon) for rectal cancer. However, she started facing difficulty in defecation 6 months after surgery. Her colonoscopy indicated stenosis of the rectal anastomosis. Endoscopic balloon dilation was performed six times on her. However, the stenosis still showed a trend of gradual aggravation. Because the patient did not undergo an enterostomy, the conventional endoscopic magnetic compression technique could not be performed. Hence, we implemented a Y-Z DMR implemented through the anus under single channel. The magnetic ring fell off nine days after the operation and the rectal stenosis was relieved. The patient was followed up for six months and reported good defecation. CONCLUSION The Y-Z DMR deformable magnetic ring is an excellent treatment strategy for patients with rectal stenosis and without enterostomy.
Collapse
Affiliation(s)
- Miao-Miao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Huan-Chen Sha
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Yuan-Fa Qin
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| | - Xiao-Peng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, Shaanxi Province, China
| |
Collapse
|
8
|
Evans LL, Lee WG, Karimzada M, Patel VH, Aribindi VK, Kwiat D, Graham JL, Cummings DE, Havel PJ, Harrison MR. Evaluation of a Magnetic Compression Anastomosis for Jejunoileal Partial Diversion in Rhesus Macaques. Obes Surg 2024; 34:515-523. [PMID: 38135738 PMCID: PMC10810932 DOI: 10.1007/s11695-023-07012-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 12/15/2023] [Accepted: 12/15/2023] [Indexed: 12/24/2023]
Abstract
PURPOSE Metabolic surgery remains underutilized for treating type 2 diabetes, as less invasive alternative interventions with improved risk profiles are needed. We conducted a pilot study to evaluate the feasibility of a novel magnetic compression device to create a patent limited caliber side-to-side jejunoileal partial diversion in a nonhuman primate model. MATERIALS AND METHODS Using an established nonhuman primate model of diet-induced insulin resistance, a magnetic compression device was used to create a side-to-side jejunoileal anastomosis. Primary outcomes evaluated feasibility (e.g., device mating and anastomosis patency) and safety (e.g., device-related complications). Secondary outcomes evaluated the device's ability to produce metabolic changes associated with jejunoileal partial diversion (e.g., homeostatic model assessment of insulin resistance [HOMA-IR] and body weight). RESULTS Device mating, spontaneous detachment, and excretion occurred in all animals (n = 5). There were no device-related adverse events. Upon completion of the study, ex vivo anastomoses were widely patent with healthy mucosa and no evidence of stricture. At 6 weeks post-device placement, HOMA-IR improved to below baseline values (p < 0.05). Total weight also decreased in a linear fashion (R2 = 0.97) with total weight loss at 6 weeks post-device placement of 14.4% (p < 0.05). CONCLUSION The use of this novel magnetic compression device to create a limited caliber side-to-side jejunoileal anastomosis is safe and likely feasible in a nonhuman primate model. The observed glucoregulatory and metabolic effects of a partial jejunoileal bypass with this device warrant further investigation to validate the long-term glucometabolic impact of this approach.
Collapse
Affiliation(s)
- Lauren L Evans
- Department of Surgery, University of California San Francisco, San Francisco, USA
| | - William G Lee
- Department of Surgery, University of California San Francisco, San Francisco, USA
| | - Mohammad Karimzada
- Department of Surgery, University of California San Francisco, San Francisco, USA
| | - Veeshal H Patel
- Department of Surgery, University of California San Francisco, San Francisco, USA
| | - Vamsi K Aribindi
- Department of Surgery, University of California San Francisco, San Francisco, USA
| | - Dillon Kwiat
- Department of Surgery, University of California San Francisco, San Francisco, USA
| | - James L Graham
- Department of Molecular Biosciences, School of Veterinary Medicine and Department of Nutrition, University of California Davis, Davis, USA
| | - David E Cummings
- Division of Metabolism, Endocrinology and Nutrition, University of Washington and VA Puget Sound Health Care System, Seattle, USA
| | - Peter J Havel
- Department of Molecular Biosciences, School of Veterinary Medicine and Department of Nutrition, University of California Davis, Davis, USA
| | - Michael R Harrison
- Department of Surgery, University of California San Francisco, San Francisco, USA.
| |
Collapse
|
9
|
Tian B, Zhang M, Ren Y, Zhang Y, Lyu Y, Yan X. Clinical application of magnetic anchor technique in laparoscopic cholecystectomy: the first retrospective study in China. Front Surg 2024; 10:1335805. [PMID: 38249312 PMCID: PMC10797062 DOI: 10.3389/fsurg.2023.1335805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 12/19/2023] [Indexed: 01/23/2024] Open
Abstract
Background and objectives Magnetic anchor technique (MAT) is frequently used in laparoscopic cholecystectomy. However, there are few reports on its clinical application in China. In this study, we retrospectively analyzed the clinical application of MAT in laparoscopic cholecystectomy in China. Materials and methods 25 patients (4 males, 21 females) who underwent laparoscopic cholecystectomy assisted by MAT at the First Affiliated Hospital of Xi'an Jiaotong University were enrolled from November 2020 to March 2021. Their records were retrospectively analyzed. The magnetic anchor device was independently designed and developed by the authors and consisted of the anchor magnet and magnetic grasping apparatus. Surgical time, intraoperative blood loss, intraoperative accidents, operator experience, postoperative incision pain score, postoperative complications, and other indicators were evaluated and analyzed. Results All patients successfully underwent laparoscopic cholecystectomy, including 3 cases of MAT-assisted transumbilical single-port LC, 16 cases of MAT-assisted 2-port LC and 6 cases of conventional 3-port LC. The median operation time was 50 min (range 30-95 min); intraoperative bleeding was less than 30 ml. The median score of surgical incision on day 1 and 3 after the operation was 3 (range 1-4) and 1 (range 1-3), respectively. All patients had no intraoperative bile duct injury, vascular injury, postoperative bleeding, bile leakage, biliary stricture and other complications. No adverse events (such as injury to adjacent organs or failure of the magnetic anchor device) occurred either during or after the operation. Conclusions The MAT-assisted laparoscopic cholecystectomy appears to be safe, feasible and effective and exhibits unique assistance in transumbilical single-port laparoscopic cholecystectomy.
Collapse
Affiliation(s)
- Boyan Tian
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Miaomiao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Yuxiang Ren
- Zonglian College, Xi’an Jiaotong University, Xi’an, China
| | - Yuhan Zhang
- Qide College, Xi’an Jiaotong University, Xi’an, China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| | - Xiaopeng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
| |
Collapse
|
10
|
Papastefan ST, De Boer C, Zeineddin S, Hu A, Harris CJ, Wall JK, Hunter CJ, Lautz TB, Goldstein SD. Innovation versus Experimentation: An Application of Ethical Frameworks to the Acceptance of Fluorescence-Guided Pediatric Surgery. J Pediatr Surg 2023; 58:1609-1612. [PMID: 37330376 DOI: 10.1016/j.jpedsurg.2023.05.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 04/26/2023] [Accepted: 05/14/2023] [Indexed: 06/19/2023]
Abstract
Innovation is essential to the advancement of the field of pediatric surgery. The natural skepticism toward new technologies in pediatrics leads to frequent confusion of surgical innovation and research. Using fluorescence-guided surgery as an archetype for this ethical discussion, we apply existing conceptual frameworks of surgical innovation to understand the distinction between innovation and experimentation, acknowledging the spectrum and "grey zone" in between. In this review, we discuss the role of Institutional Review Boards in evaluating surgical practice innovations, and the aspects of certain surgical innovations that are distinct from experimentation, including a thorough understanding of the risk profile, preexisting use in humans, and adaptation from related fields. Examining fluorescence-guided surgery through these existing frameworks as well as the concept of equipoise, we conclude that new applications of indocyanine green do not constitute human subjects research. Most importantly, this example gives practitioners a lens through which they may appraise potential surgical innovations to allow for a sensible and efficient improvement of the field of pediatric surgery. LEVEL OF EVIDENCE: V.
Collapse
Affiliation(s)
- Steven T Papastefan
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA; Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA.
| | - Christopher De Boer
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA
| | - Suhail Zeineddin
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA
| | - Andrew Hu
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA; Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Courtney J Harris
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA; Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - James K Wall
- Division of Pediatric Surgery, Lucile Packard Children's Hospital, Stanford, CA, USA
| | - Catherine J Hunter
- Division of Pediatric Surgery, Oklahoma Children's Hospital, Oklahoma City, OK, USA
| | - Timothy B Lautz
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA; Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Seth D Goldstein
- Department of Surgery, Division of Pediatric Surgery, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA; Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| |
Collapse
|
11
|
Kotlovsky AM, Muensterer OJ, Nikolaev VV, Razumovskiy AY. Magnetic Compression Anastomosis-Past Experience and Current Proposals for Further Development in Pediatric Minimally Invasive Surgery. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1328. [PMID: 37628327 PMCID: PMC10453638 DOI: 10.3390/children10081328] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/16/2023] [Accepted: 07/29/2023] [Indexed: 08/27/2023]
Abstract
Originating in the 1970s, magnetic compression anastomosis (MCA) has lately been revisited with a focus on minimal invasive surgery (MIS). The aim of this report is to reappraise our earlier experience with MCA with the intention of facilitating future MCA advancement. A retrospective review was conducted regarding preclinical experiments and clinical trials at a single institution from 1980 to 1995. The reviewed information was compiled and appraised to generate proposals for future MCA use. The experimental studies, including 250 MCA cases in gastrointestinal and urinary tract animal models, demonstrated the technical versatility of MCA as well as the superior biomechanical characteristics in comparison to hand-sewn anastomoses. Clinical trials encompassed 87 MCA procedures in 86 children, 2 to 10 years of age, involving the following techniques: non-operative esophageal recanalization (n = 15), non-operative ileostomy undiversion (n = 46), Swenson pull-through (n = 10), non-operative urethral recanalization (n = 5), and extravesical ureterocystoneostomy (n = 11). Clinical MCA was found to be successful in over 87% of cases. MCA limitations concerning anastomotic failure and scarring were thought to be mostly due to inadequate magnetic compression. Based on our historic experience, we propose further research on the technical aspects of MCA, along with the biological aspects of anastomotic tissue remodeling. Magnets should be designed and manufactured for a wide spectrum of pediatric surgical indications, particularly in combination with novel MIS techniques.
Collapse
Affiliation(s)
- Anatole M. Kotlovsky
- Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, Ludwig-Maximilians-University Medical Center, Lindwurmstrasse, 480337 Munich, Germany;
| | - Oliver J. Muensterer
- Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, Ludwig-Maximilians-University Medical Center, Lindwurmstrasse, 480337 Munich, Germany;
| | - Vasily V. Nikolaev
- Department of Pediatric Surgery, N.I. Pirogov Russian National Research Medical University, Russian Children’s Hospital, Leninsky Prosp 117, 119571 Moscow, Russia; (V.V.N.); (A.Y.R.)
| | - Alexander Y. Razumovskiy
- Department of Pediatric Surgery, N.I. Pirogov Russian National Research Medical University, Russian Children’s Hospital, Leninsky Prosp 117, 119571 Moscow, Russia; (V.V.N.); (A.Y.R.)
- Department of Pediatric Surgery, Pirogov Russian National Research Medical University, Filatov Children’s Clinical Hospital, Ulitsa Sadovo-Kudrinskay 13, 123001 Moscow, Russia
| |
Collapse
|
12
|
Zhang MM, Li CG, Xu SQ, Mao JQ, Ren YX, Zhang YH, Ma J, Shi AH, Lyu Y, Yan XP. Primary animal experiment to test the feasibility of a novel Y-Z magnetic hepatic portal blocking band. World J Gastrointest Surg 2023; 15:1286-1293. [PMID: 37555113 PMCID: PMC10405127 DOI: 10.4240/wjgs.v15.i7.1286] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2023] [Revised: 03/08/2023] [Accepted: 05/05/2023] [Indexed: 07/21/2023] Open
Abstract
BACKGROUND Hepatic portal blood flow occlusion is a common technique for reducing hepatic hemorrhage during hepatectomy. We designed a novel Y-Z magnetic hepatic portal blocking band (Y-Z MHPBB) based on the principle of magnetic compression technique. AIM To introduce the Y-Z MHPBB device and verify the feasibility of this device for hepatic portal blood flow occlusion in dogs. METHODS Ten beagles were randomly divided into the experimental group and control group. The operation time, intraoperative blood loss, the number of portal blood flow occlusions, the total time spent on adjusting the blocking band, and the average time spent on adjusting the blocking band were recorded. The surgeons evaluated the feasibility and flexibility of the two portal occlusion devices. RESULTS Laparoscopic hepatectomy was successfully performed in both the experimental group and control group. There was no statistical difference between the two groups in the operation time, intraoperative blood loss, and the number of hepatic portal blood flow occlusions. With respect to the total time spent on adjusting the blocking band and the average time spent on adjusting the blocking band, the experimental group showed significantly better outcomes than the control group, with a statistical difference (P < 0.05). The operators found that the Y-Z MHPBB was superior to the modified T-tube in terms of operational flexibility. CONCLUSION The Y-Z MHPBB seems to be an ingenious design, accurate blood flow occlusion effect, and good flexibility; and it can be used for hepatic portal blood flow occlusion during laparoscopic hepatectomy.
Collapse
Affiliation(s)
- Miao-Miao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Chen-Guang Li
- Department of Critical Care Medicine, China-Japan Union Hospital of Jilin University, Changchun 130000, Jilin Province, China
| | - Shu-Qin Xu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Jian-Qi Mao
- Zonglian College, Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Yu-Xiang Ren
- Zonglian College, Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Yu-Han Zhang
- Qide College, Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Jia Ma
- Department of Surgical Oncology, Shaanxi Provincial People's Hospital, Xi'an 710068, Shaanxi Province, China
| | - Ai-Hua Shi
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| | - Xiao-Peng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
- National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710061, Shaanxi Province, China
| |
Collapse
|
13
|
Lee WG, Evans LL, Johnson SM, Woo RK. The Evolving Use of Magnets in Surgery: Biomedical Considerations and a Review of Their Current Applications. Bioengineering (Basel) 2023; 10:bioengineering10040442. [PMID: 37106629 PMCID: PMC10136001 DOI: 10.3390/bioengineering10040442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/30/2023] [Accepted: 03/31/2023] [Indexed: 04/05/2023] Open
Abstract
The novel use of magnetic force to optimize modern surgical techniques originated in the 1970s. Since then, magnets have been utilized as an adjunct or alternative to a wide array of existing surgical procedures, ranging from gastrointestinal to vascular surgery. As the use of magnets in surgery continues to grow, the body of knowledge on magnetic surgical devices from preclinical development to clinical implementation has expanded significantly; however, the current magnetic surgical devices can be organized based on their core function: serving as a guidance system, creating a new connection, recreating a physiologic function, or utilization of an internal–external paired magnet system. The purpose of this article is to discuss the biomedical considerations during magnetic device development and review the current surgical applications of magnetic devices.
Collapse
Affiliation(s)
- William G. Lee
- Department of Surgery, Cedars-Sinai Medical Center, Los Angeles, CA 90048, USA
| | - Lauren L. Evans
- Department of Surgery, Cedars-Sinai Medical Center, Los Angeles, CA 90048, USA
| | - Sidney M. Johnson
- Department of Surgery, University of Hawaii, Honolulu, HI 96822, USA
| | - Russell K. Woo
- Department of Surgery, University of Hawaii, Honolulu, HI 96822, USA
| |
Collapse
|
14
|
Zhang M, Ji L, Chang K, Wang Y, Lyu Y, Yan X. A novel micromagnetic ring used for biliary-enteric anastomosis in rats. J Pediatr Surg 2022; 57:451-456. [PMID: 34996607 DOI: 10.1016/j.jpedsurg.2021.12.011] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 11/17/2021] [Accepted: 12/09/2021] [Indexed: 11/16/2022]
Abstract
BACKGROUND To explore the feasibility of micromagnetic ring in establishing biliary-enteric anastomosis in a rat model. METHODS A new micromagnetic ring suitable for rat biliary-enteric anastomosis model was designed and fabricated. The common bile ducts of 20 Sprague-Dawley albino rats were ligated and dilated after 2 weeks. Surgery for biliary-enteric anastomosis was completed by using micromagnetic ring. The anastomosis time, postoperative survival rate, liver function, liver histopathology, and complications were recorded. After 28 days, anastomotic specimens were obtained to observe healing with the naked eye and light microscopy. RESULTS Among the 20 Sprague-Dawley albino rats, one rat showed bile leakage and died one week after ligation of the common bile duct and another rat was removed from the experiment because there was no obvious dilatation of the common bile duct. The remaining 18 rats successfully underwent surgery for biliary-enteric anastomosis using micromagnetic ring, with an average anastomosis time of 7.10 ± 1.15 min (range, 5.17-9.50 min). The expulsion time of micromagnetic anastomosis rings was 11.94 ± 2.48 days (range, 8-17 days). The bilirubin level dropped to normal 1 week after surgery. Biliary-enteric anastomotic specimens were obtained 28 days after surgery, and microscopic observation showed that the mucosal layer of the anastomosis had good continuity and the anastomosis was smooth. CONCLUSION A micromagnetic ring can be used to construct a rat biliary-enteric anastomosis model, and it offers advantages, such as simple operation and reliable anastomosis effect.
Collapse
Affiliation(s)
- Miaomiao Zhang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Lin Ji
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Kaixi Chang
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Yirui Wang
- Qide College, Xi'an Jiaotong University, Xi'an, PR China
| | - Yi Lyu
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China
| | - Xiaopeng Yan
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China; National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, PR China.
| |
Collapse
|
15
|
Holler AS, König TT, Chen C, Harrison MR, Muensterer OJ. Esophageal Magnetic Compression Anastomosis in Esophageal Atresia Repair: A PRISMA-Compliant Systematic Review and Comparison with a Novel Approach. CHILDREN (BASEL, SWITZERLAND) 2022; 9:children9081113. [PMID: 35892616 PMCID: PMC9394416 DOI: 10.3390/children9081113] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Revised: 07/12/2022] [Accepted: 07/22/2022] [Indexed: 12/29/2022]
Abstract
The use of magnet compression to endoscopically create an esophageal anastomosis is an intriguing approach to esophageal atresia repair, but published cases with an existing available device have demonstrated mixed success. One major shortcoming has been the formation of subsequent severe, recalcitrant strictures after primary repair. To address the limitations of the existing device, we recently introduced and reported success with specially designed bi-radial magnets that exhibit a novel geometry and unique tissue compression profile. The aim of this study is to compare the outcomes using our novel device (novel group, NG) with those of previous reports which utilized the historical device (historic group, HG) in a PRISMA-compliant systematic review. Seven studies were eligible for further analysis. Additionally, one of our previously unreported cases was included in the analysis. Esophageal pouch approximation prior to primary repair was performed more frequently in the NG than in the HG (100% NG vs. 21% HG; p = 0.003). There was no difference in the overall postoperative appearance of postoperative stricture (95% HG vs. 100% NG; p = 0.64). The number of postoperative dilatations trended lower in the NG (mean 4.25 NG vs. 9.5 HG; p = 0.051). In summary, magnetic compression anastomosis adds a new promising treatment option for patients with complex esophageal atresia. Prior approximation of pouches and a novel magnet design have the potential to lower the rate of stricture formation.
Collapse
Affiliation(s)
- Anne-Sophie Holler
- Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, University Hospital, LMU Munich, 55131 Mainz, Germany;
- Correspondence: ; Tel.: +49-894-4005-3101
| | - Tatjana Tamara König
- Department of Pediatric Surgery, Universitätsmedizin, Johannes-Gutenberg University, 55131 Mainz, Germany;
| | - Caressa Chen
- Department of Surgery and Bioengineering & Therapeutic Sciences, University of California, San Francisco, CA 94102, USA;
| | - Michael R. Harrison
- Division of Pediatric Surgery, Department of Surgery, University of California, San Francisco, CA 94102, USA;
| | - Oliver J. Muensterer
- Department of Pediatric Surgery, Dr. von Hauner Children’s Hospital, University Hospital, LMU Munich, 55131 Mainz, Germany;
| |
Collapse
|