BPG is committed to discovery and dissemination of knowledge
Retrospective Cohort Study
Copyright: ©Author(s) 2026. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial (CC BY-NC 4.0) license. No commercial re-use. See permissions. Published by Baishideng Publishing Group Inc.
World J Diabetes. Dec 15, 2026; 17(12): 124953
Published online Dec 15, 2026. doi: 10.4239/wjd.124953
Continuous glucose monitoring with integrated digital care in real-world type 2 diabetes: Glycemic control, self-management, and nocturnal hypoglycemia detection
Di-Fei Lu, Ang Li, Yi-Min Shao, Jing-Cui Guo, Pei-Heng Zhang, Jian Zhang, Hui-Ying Liu, Rui-Yan Fan, Ying Gao, Jun-Qing Zhang, Xiao-Hui Guo
Di-Fei Lu, Ang Li, Yi-Min Shao, Jing-Cui Guo, Pei-Heng Zhang, Jian Zhang, Ying Gao, Jun-Qing Zhang, Xiao-Hui Guo, Department of Endocrinology, Peking University First Hospital, Beijing 100034, China
Hui-Ying Liu, Rui-Yan Fan, iHealth Labs China Co., Ltd, Beijing 100034, China
Author contributions: Lu DF conducted statistical analysis and wrote the manuscript; Li A, Shao YM, Guo JC, and Zhang PH participated in the establishment of the study cohort; Lu DF and Guo XH designed the study protocol; Zhang J, Gao Y, and Guo XH revised the manuscript; Fan R performed data collection; and all authors thoroughly reviewed and endorsed the final manuscript.
AI contribution statement: Portions of this manuscript were edited using AI tools solely for language refinement. The authors carefully reviewed and verified all AI-assisted outputs and take full responsibility for the scientific content of the manuscript.
Institutional review board statement: This study was approved by the Medical Ethics Committee of Peking University First Hospital, approval No. 2025R0034-0001.
Informed consent statement: Signed informed consent was obtained from all participants.
Conflict-of-interest statement: All the authors report no relevant conflicts of interest for this article.
STROBE statement: The authors have read the STROBE Statement-checklist of items, and the manuscript was prepared and revised according to the STROBE Statement-checklist of items.
Data sharing statement: Original data are available after request to the corresponding author.
Corresponding author: Xiao-Hui Guo, Chief Physician, Professor, Department of Endocrinology, Peking University First Hospital, No. 8 Xishiku Street, Xicheng District, Beijing 100034, China. bdyyguoxiaohui@sina.com
Received: July 2, 2026
Revised: August 17, 2026
Accepted: October 12, 2026
Published online: December 15, 2026
Processing time: 155 Days and 1.9 Hours
Abstract
BACKGROUND

Continuous glucose monitoring (CGM) has recently become a widely used tool for monitoring blood glucose levels.

AIM

To evaluate the efficacy of CGM on glycemic control and self-management behaviors among type 2 diabetes (T2D) patients in real clinical settings, and to analyze the risk factors for asymptomatic nocturnal hypoglycemia.

METHODS

This was a single-center retrospective real-world cohort study. A total of 1087 adult patients with T2D who received CGM monitoring were enrolled. Baseline demographic data, biochemical indicators, glycemic profiles, and self-management related data were collected. Glycemic indicators, weekly blood glucose monitoring frequency and online dietary guidance frequency were compared before and after CGM application. Spearman’s correlation analysis and binary logistic regression analysis were adopted to explore the influencing factors of CGM-detected asymptomatic nocturnal hypoglycemia.

RESULTS

Of 1362 screened adults with type 2 diabetes, 1087 were enrolled and 615 completed paired 3-month follow-up for glucose remeasurements. Retained participants had higher rates of male sex, diabetic kidney and polyneuropathy, and higher baseline glucose monitoring frequency compared with the 472 lost-to follow-up. In the full cohort, 55.7% experienced suspected asymptomatic nocturnal sensor detected hypoglycemia. Among paired participants, multimodal CGM digital care plus medication adjustment was associated with reduced HbA1c, fasting and postprandial glucose (all P < 0.005). Medication regimens were substantially revised; weekly capillary self-monitoring decreased while app based dietary guidance usage increased (all P < 0.05). Lower post dinner-to-bedtime sensor glucose correlated with hypoglycemia risk in univariable analysis (r = -0.111, P < 0.001). The multivariable model showed poor overall performance, with only borderline positive association for weekly glucose monitoring frequency (P = 0.093).

CONCLUSION

CGM combined with digital integrated diabetes care is associated with improved glycemic control and utilization of app-based online dietary guidance in T2D patients, and it is capable of identifying asymptomatic nocturnal hypoglycemia in a timely manner. Appropriate post dinner-to-bedtime sensor glucose levels may be associated with a lower risk of asymptomatic nocturnal hypoglycemia.

Keywords: Continuous glucose monitoring; Type 2 diabetes; Hypoglycemia; Diabetes self-management education; Glycemic control

Core Tip: This real-world cohort included 1087 type 2 diabetes patients using continuous glucose monitoring (CGM). Multimodal care integrating CGM with digital diabetes support is associated with glycemic changes, self-management shifts, and detection of suspected asymptomatic nocturnal sensor detected hypoglycemia in real world adults with type 2 diabetes. Appropriate post-dinner-to-bedtime glucose may be correlated with the risk of asymptomatic nocturnal hypoglycemia. CGM may help improve glycemic control, optimize self-management, and detect hidden nocturnal hypoglycemia.

Write to the Help Desk