Table 1 Baseline patient and procedural characteristics
| FNA alone (n = 17) | FNB alone (n = 56) | FNA with FNB (n = 33) | P value | |
| Age, mean (range) | 55.2 (30-75) | 55.0 (23-84) | 56.6 (37-76) | 0.7502 |
| Male, n (%) | 5 (29.4) | 24 (42.9) | 15 (25.5) | 0.5533 |
| Needle type | ||||
| FNA needle (Expect) | 16 | 0 | 31 | - |
| Franseen needle (Acquire) | 0 | 50 | 32 | - |
| Fork-tip needle (SharkCore) | 0 | 3 | 0 | - |
| Reverse bevel needle (ProCore) | 0 | 1 | 1 | - |
| Other1 | 0 | 1 | 3 | - |
| Not documented | 1 | 3 | 2 | - |
| Needle passes, mean (range) | 3.4 (1-5) | 3.4 (1-8) | 2.8 (1-8) | - |
Table 2 Indications for endoscopic ultrasound-guided fine needle aspiration and endoscopic ultrasound-guided fine needle biopsy
| Indication (n = 106) | n (%) |
| Pancreatic mass | 33 (31.1) |
| Gastric mass | 19 (17.9) |
| Liver biopsy | 15 (14.2) |
| Pancreatic cyst | 14 (13.2) |
| Lymph node | 6 (5.7) |
| Biliary | 5 (4.7) |
| Extraluminal | 4 (3.8) |
| Pancreatitis | 4 (3.8) |
| Rectal | 2 (1.9) |
| Small bowel | 2 (1.9) |
| Mediastinal | 1 (0.9) |
| Esophageal | 1 (0.9) |
Table 3 Diagnostic yield and specimen adequacy, n (%)
| Diagnostic yield | Specimen adequacy | |
| FNA alone (n = 17) | 8 (47.1) | 9 (52.9) |
| FNB alone (n = 56) | 48 (85.7) | 50 (89.3) |
| FNA with FNB (n = 33) | 28 (84.8) | 28 (84.8) |
- Citation: Ku L, Shahshahan MA, Hou LA, Eysselein VE, Reicher S. Improved diagnostic yield of endoscopic ultrasound-fine needle biopsy with histology specimen processing. World J Gastrointest Endosc 2020; 12(8): 212-219