Copyright
©The Author(s) 2015. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Gastrointest Endosc. Jun 10, 2015; 7(6): 665-669
Published online Jun 10, 2015. doi: 10.4253/wjge.v7.i6.665
Published online Jun 10, 2015. doi: 10.4253/wjge.v7.i6.665
Metallic stent insertion with double-balloon endoscopy for malignant afferent loop obstruction
Masakuni Fujii, Shuhei Ishiyama, Hiroaki Saito, Mamoru Ito, Akiko Fujiwara, Masao Yoshioka, Junji Shiode, Department of Internal Medicine, Okayama Saiseikai General Hospital, Okayama 700-8511, Japan
Takefumi Niguma, Department of Surgery, Okayama Saiseikai General Hospital, Okayama 700-8511, Japan
Author contributions: Fujii M, Ishiyama S, Saito H, Ito M, Fujiwara A, Niguma T, Yoshioka M and Shiode J were responsible for the care of the patients; Fujii M, Ishiyama S and Saito H performed endoscopic therapy; Niguma T conducted patient follow-ups; Fujii M, Yoshioka M and Shiode J wrote the manuscript; all authors read and approved the final manuscript.
Ethics approval: Case reports do not require examination by the Okayama Saiseikai General Hospital Institutional Review Board. Ethical considerations were upheld and patient personal information was protected.
Informed consent: All study participants, or their legal guardian, provided written informed consent prior to study enrollment.
Conflict-of-interest: The authors declare that there are no competing financial or personal relationships with other people or organizations that could inappropriately influence the research.
Open-Access: This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Correspondence to: Masakuni Fujii, MD, Department of Internal Medicine, Okayama Saiseikai General Hospital, 1-17-18 Ifuku-cho, Okayama 700-8511, Japan. sktng334@yahoo.co.jp
Telephone: +81-86-2237151 Fax: +81-86-2357636
Received: October 8, 2014
Peer-review started: October 8, 2014
First decision: November 14, 2014
Revised: December 19, 2014
Accepted: March 16, 2015
Article in press: March 18, 2015
Published online: June 10, 2015
Processing time: 254 Days and 16.6 Hours
Peer-review started: October 8, 2014
First decision: November 14, 2014
Revised: December 19, 2014
Accepted: March 16, 2015
Article in press: March 18, 2015
Published online: June 10, 2015
Processing time: 254 Days and 16.6 Hours
Core Tip
Core tip: Malignant afferent loop and Roux-limb obstruction are intractable complications caused by postoperative recurrence of biliary tract cancer. Metallic stent insertion using an overtube under double-balloon endoscopy is a safe and feasible treatment option in such cases.