Letter to the Editor
Copyright ©The Author(s) 2025.
World J Hepatol. Feb 27, 2025; 17(2): 100243
Published online Feb 27, 2025. doi: 10.4254/wjh.v17.i2.100243
Table 1 Values of mean squared error and peak signal-to-noise ratio in ultrasound images with Gaussian noise and Wiener denoise filters in different stages of non-alcoholic fatty liver disease
NAFLD stages
Normal
Mild
Moderate
Severe
MSE values in ultrasound image under gray level6.225 × 1033.998 × 1033.232 × 1035.140 × 103
PSNR values in ultrasound image under gray level10.18912.11213.03611.021
MSE values in ultrasound image with Gaussian noise under gray level15.2551.69810.12811.063
PSNR values in ultrasound image with Gaussian noise under gray level36.29745.83338.07537.692
MSE values in ultrasound image with Gaussian noise and Wiener denoise under gray level25.40729.12728.15526.793
PSNR values in ultrasound image with Gaussian noise and Wiener denoise under gray level34.08133.48833.63533.851