Copyright
©The Author(s) 2024.
World J Gastroenterol. Mar 7, 2024; 30(9): 1121-1131
Published online Mar 7, 2024. doi: 10.3748/wjg.v30.i9.1121
Published online Mar 7, 2024. doi: 10.3748/wjg.v30.i9.1121
Table 1 Methods for detecting diseases in experimental and control groups
| EGD | ||||
| Positive | Negative | Total | ||
| ds-MCE | Positive | a | b | a + b (R1) |
| Negative | c | d | c + d (R2) | |
| Total | a + c (C1) | b + d (C2) | a + b + c + d (N) | |
Table 2 Demographic and baseline characteristics
| Subjects (n = 50) | |
| Sex, % (n) | |
| Male | 54% (27/50) |
| Female | 46% (23/50) |
| Age (yr) | |
| n | 50 |
| Mean | 53.26 |
| Median | 56 |
| Min, Max | 22, 73 |
| Height (cm) | |
| n | 50 |
| Mean | 164.3 |
| Median | 162 |
| Min, Max | 150.0, 182.0 |
| Weight (kg) | |
| n | 50 |
| Mean | 63.76 |
| Median | 63.5 |
| Min, Max | 42, 93 |
| BMI (kg/m2) | |
| n | 50 |
| Mean | 23.5 |
| Median | 23.34 |
| Min, Max | 16.41, 31.25 |
| Medical history | |
| Esophagitis | 48 |
| Barrett's esophagus | 1 |
| Esophageal hiatal hernia | 2 |
| Superficial gastritis | 8 |
| Atrophic gastritis | 2 |
Table 3 Detection of esophageal lesions by esophagogastroduodenoscopy and detachable string magnetically controlled capsule endoscopy
| EGD | ||||
| Positive | Negative | Total | ||
| ds-MCE | Positive | 18 | 4 | 22 |
| Negative | 3 | 25 | 28 | |
| Total | 21 | 29 | 50 | |
Table 4 Detection of esophageal lesions by esophagogastroduodenoscopy and detachable string magnetically controlled capsule endoscopy
| Primary endpoint | 95%CI |
| Sensitivity | 85.71% (62.64%, 96.24%) |
| Specificity | 86.21% (67.43%, 95.49%) |
| Positive predictive value | 81.82% (58.99%,94.01%) |
| Negative predictive value | 89.29% (70.63%, 97.19%) |
| Diagnostic accuracy | 86% (72.64%,93.72%) |
Table 5 Perception analysis of subjects undergoing esophagogastroduodenoscopy and detachable string magnetically controlled capsule endoscopy examination
| Projects | EGD (n = 49) | ds-MCE (n = 50) |
| Comfort level | ||
| 0 Very comfort | 6 | 13 |
| 1 Comfort | 13 | 27 |
| 2 Tolerable | 23 | 10 |
| 3 Uncomfortable | 3 | 0 |
| 4 Very uncomfortable | 4 | 0 |
| P value (Kruskal-Wallis test) | < 0.0001 | |
| Pain during the examination | ||
| 0 No | 23 | 40 |
| 1 A little | 18 | 9 |
| 2 Mild | 7 | 1 |
| 3 Serious | 1 | 0 |
| 4 Unbearable | 0 | 0 |
| P value (Kruskal-Wallis test) | 0.0004 | |
| Discomfort during the examination | ||
| 0 No | 14 | 31 |
| 1 A little | 21 | 14 |
| 2 Mild | 6 | 5 |
| 3 Serious | 7 | 0 |
| 4 Unbearable | 0 | 0 |
| P value (Kruskal-Wallis test) | 0.0003 | |
| Pain after the examination | ||
| 0 No | 29 | 44 |
| 1 A little | 15 | 6 |
| 2 Mild | 5 | 0 |
| 3 Serious | 0 | 0 |
| 4 Unbearable | 0 | 0 |
| P value (Kruskal-Wallis test) | 0.0008 | |
| Discomfort after the examination | ||
| 0 No | 23 | 42 |
| 1 A little | 18 | 7 |
| 2 Mild | 7 | 1 |
| 3 Serious | 1 | 0 |
| 4 Unbearable | 0 | 0 |
| P value (Kruskal-Wallis test) | < 0.0001 | |
| Convenience of inspection | ||
| 0 Very convenient | 14 | 25 |
| 1 Convenient | 29 | 25 |
| 2 Inconvenient | 5 | 0 |
| 3 Very inconvenient | 1 | 0 |
| P value (Kruskal-Wallis test) | 0.0074 | |
- Citation: Yang YL, Qin HW, Chen ZY, Fan HN, Yu Y, Da W, Zhu JS, Zhang J. Detachable string magnetically controlled capsule endoscopy for the noninvasive diagnosis of esophageal diseases: A prospective, blind clinical study. World J Gastroenterol 2024; 30(9): 1121-1131
- URL: https://www.wjgnet.com/1007-9327/full/v30/i9/1121.htm
- DOI: https://dx.doi.org/10.3748/wjg.v30.i9.1121