Copyright
©2014 Baishideng Publishing Group Co.
World J Gastroenterol. Mar 21, 2014; 20(11): 2746-2750
Published online Mar 21, 2014. doi: 10.3748/wjg.v20.i11.2746
Published online Mar 21, 2014. doi: 10.3748/wjg.v20.i11.2746
Indicator | Definition | Acceptable level |
Bowel preparation | Proportion of procedures in which colon cleansing is considered excellent or good | > 90% |
Adenoma detection rate | Proportion of colonoscopies performed in asymptomatic individuals over 50 in which at least one adenoma has been detected | > 20% |
(men > 25% and women > 15%) | ||
Withdrawal time | Mean time from cecal intubation to colonoscopy extraction through the anus | > 6 min |
Cecal intubation rate | Proportion of procedures in which cecal intubation is achieved | > 95% |
Study | Subjects (n) | Perspective | Outcomes | Results |
Bowles et al[17] | 9223 | Prospective | Cecal intubation rate | Poor bowel preparation (19.6%) |
Bernstein et al[18] | 693 | Prospective | Predictor of cecal intubation time (≥ 20 min) | Poor bowel preparation (P = 0.0077) |
Kim et al[19] | 909 | Prospective | Prolonged insertion time (> 10 min) | Inadequate bowel cleaning |
(OR = 2.8, 95%CI: 1.41-5.56, P = 0.003) | ||||
Nelson et al[20] | 3196 | Prospective | Predictor of incomplete colonoscopy | Poor bowel preparation |
(failure rate = 19.3%, P = 0.001) | ||||
Aslinia et al[21] | 5477 | Retrospective | Cecal intubation rate | Inadequate bowel preparation |
(OR = 0.17, 95%CI: 0.14-0.21, P < 0.001) |
- Citation: Jang JY, Chun HJ. Bowel preparations as quality indicators for colonoscopy. World J Gastroenterol 2014; 20(11): 2746-2750
- URL: https://www.wjgnet.com/1007-9327/full/v20/i11/2746.htm
- DOI: https://dx.doi.org/10.3748/wjg.v20.i11.2746