Rapid Communication
Copyright ©2007 Baishideng Publishing Group Co.
World J Gastroenterol. Feb 14, 2007; 13(6): 906-911
Published online Feb 14, 2007. doi: 10.3748/wjg.v13.i6.906
Table 1 Demographic and clinical data of the patients
TN-EGDTO-EGDC-EGDP
Patients (n)454153
Gender (m/f)22/2315/2624/29NS
Age (yr; mean ± SD)45.73 ± 12.5943.92 ± 14.9743.83 ± 13.68NS
Patients with previous EGD, n (%)17 (37.7)17 (41.4)19 (35.8)NS
Baseline anxiety score in VAS (mean ± SD)45.36 ± 27.7144.34 ± 32.2545.84 ± 30.35NS
Baseline oxygen saturation (%; mean ± SD)98.58 ± 1.4198.48 ± 1.3898.47 ± 1.54NS
Baseline hart rate (bpm; mean ± SD)84.92 ± 16.1286.07 ± 15.8086.32 ± 15.01NS
Successful completion EGD, n (%)41 (91.1)40 (97.5)51 (96.2)NS
Duration of EGD (min; mean ± SD)3.11 ± 1.602.25 ± 1.452.49 ± 1.64< 0.05
Tachycardia, n (%)1 (2.4)1 (2.5)3 (5.9)NS
Blood oxygen desaturation, n (%)0 (0)0 (0)2 (3.9)NS
Biopsy during EGD, n (%)19 (46.3)16 (40.0)24 (47.0)NS
Complications, n (%)1 (2.4)0 (0)0 (0)NS
Table 2 Patients’ and endoscopists’ evaluations (mean ± SD)
TN-EGD (n = 41)TO-EGD (n = 40)C-EGD (n = 51)PStatistical procedure
Patients’ assessment
Intubation (pain)24.49 ± 21.7020.08 ± 23.4626.53 ± 31.18NSANOVA-RM
Overall discomfort22.49 ± 23.5932.35 ± 28.6534.02 ± 31.21NSANOVA-RM
Choking9.66 ± 13.4419.72 ± 25.8025.37 ± 33.77NSKruskal-Wallis
Nausea/Vomiting21.80 ± 26.8939.57 ± 34.4035.39 ± 34.27NSKruskal-Wallis
Overall tolerance3.95 ± 0.713.70 ± 0.723.29 ± 0.90< 0.001ANOVA-RM
Endoscopists’ assessment
Difficulty in intubation10.97 ± 16.716.57 ± 10.379.61 ± 14.78NSKruskal-Wallis
Intubation (pain)16.34 ± 18.3715.00 ± 17.4820.10 ± 25.56NSANOVA-RM
Overall discomfort8.22 ± 9.7614.85 ± 16.8423.04 ± 27.31NSANOVA-RM
Overall tolerance4.56 ± 0.594.18 ± 0.933.63 ± 1.08< 0.01ANOVA-RM
Table 3 Answers to the questions of “how did you tolerate EGD and what you were expecting of?”
TN-EGD(n = 41)TO-EGD(n = 40)C-EGD(n = 51)
Worse than expected, n (%)2 (4.9)7 (17.5)12 (23.5)
As expected, n (%)9 (21.9)11 (27.5)19 (37.3)
Better than expected, n (%)30 (73.2)22 (55.0)20 (39.2)
Table 4 Results of the endoscopists’ evaluation of the performances of endoscopes
TN-EGD(n = 41)TO-EGD(n = 40)C-EGD(n = 51)P
Endoscopists’ score (mean ± SD)
Image quality87.85 ± 14.3489.57 ± 11.0091.98 ± 11.85NS
Suction81.90 ± 9.9884.82 ± 11.8294.37 ± 7.49< 0.001
Air insufflation/washing of the lens83.90 ± 13.7085.80 ± 13.3494.76 ± 6.49< 0.001
Reaching of the second portionof the duodenum, n (%)41 (100)40 (100)51 (100)NS
Adequate biopsy sampling, n (%)19/19 (100)16/16 (100)24/24 (100)NS