Copyright
©2007 Baishideng Publishing Group Co.
World J Gastroenterol. Sep 28, 2007; 13(36): 4891-4896
Published online Sep 28, 2007. doi: 10.3748/wjg.v13.i36.4891
Published online Sep 28, 2007. doi: 10.3748/wjg.v13.i36.4891
Sequence | TR | TE | NEX | Matrix | FOV (cm) | Thickness Intersection gap (mm) Flip angle (mm) |
T2-FSE/TSE with fat suppression | 3333-4000 | 98 | 2 | 256 × 160 | 36 × 36 | 8 2 - |
GRE T1WI | 150 | 2 | 1 | 256 × 128 | 36 × 36 | 8 2 90° |
GRE T2*WI | 150 | 11.5 | 1 | 256 × 160 | 36 × 36 | 8 2 10° |
Sequence | n (%) | ||
< 1 cm | 1-3 cm | > 3 cm | |
(n = 44 ) | (n = 68) | (n = 21 ) | |
1 Pre-contrast T1WI GRE | 15 (34.1)b | 48 (70.6)b | 21 (100.0) |
2 Pre-contrast FSE T2WI with fat suppression | 24 (54.5)b | 61 (89.7) | 21 (100.0) |
3 Dynamic Gd-DTPA- enhanced T1WI GRE | 35 (79.5)a | 67 (98.5) | 21 (100.0) |
4 Dynamic ferucarbotran- enhanced T1WI GRE | 32 (72.7) | 62 (91.2) | 21 (100.0) |
5 Delayed ferucarbotran-enhanced FSE T2WI with fat suppression | 41 (93.2) | 68 (100) | 21 (100.0) |
6 Delayed ferucarbotran- enhanced GRE T2*WI | 39 (88.6) | 67 (98.5) | 21 (100.0) |
-
Citation: Cheng WZ, Zeng MS, Yan FH, Rao SX, Shen JZ, Chen CZ, Zhang SJ, Shi WB. Ferucarbotran
versus Gd-DTPA-enhanced MR imaging in the detection of focal hepatic lesions. World J Gastroenterol 2007; 13(36): 4891-4896 - URL: https://www.wjgnet.com/1007-9327/full/v13/i36/4891.htm
- DOI: https://dx.doi.org/10.3748/wjg.v13.i36.4891