Copyright
©2007 Baishideng Publishing Group Co.
World J Gastroenterol. Jul 21, 2007; 13(27): 3671-3676
Published online Jul 21, 2007. doi: 10.3748/wjg.v13.i27.3671
Published online Jul 21, 2007. doi: 10.3748/wjg.v13.i27.3671
Table 1 Studies comparing diagnostic yields of CE to PE in obscure GI bleeding
| Studies | n | Diagnostic yield (%) | |
| CE | PE | ||
| Ell et al, 2002[30] | 32 | 83 | 30 |
| Lewis et al, 2002[37] | 21 | 55 | 30 |
| Lim et al, 2002[33] | 20 | 70 | 45 |
| Hartmann et al, 2003[36] | 33 | 76 | 21 |
| Van Gossum et al, 2003[45] | 21 | 52 | 61 |
| Saurin et al, 2003[35] | 58 | 69 | 38 |
| Mylonaki et al, 2003[32] | 50 | 68 | 32 |
| Ge et al, 2004[38] | 36 | 65 | 28 |
| Adler et al, 2004[34] | 20 | 70 | 25 |
| Mata et al, 2004[31] | 42 | 74 | 19 |
| Leighton et al, 2006[39] | 20 | 50 | 20 |
- Citation: Ersoy O, Sivri B, Bayraktar Y. How helpful is capsule endoscopy to surgeons? World J Gastroenterol 2007; 13(27): 3671-3676
- URL: https://www.wjgnet.com/1007-9327/full/v13/i27/3671.htm
- DOI: https://dx.doi.org/10.3748/wjg.v13.i27.3671