Table 1 Accuracy and precision data for assays of metformin and phenol red in perfused solution
| Concentration(μg/mL) | Intra-d (n = 5) | Inter-d (n = 5) | ||
| Accuracy Mean RE % | Precision CV % | Accuracy Mean RE % | Precision CV % | |
| Metformin | ||||
| 10 | -0.9 | 3.2 | -3.5 | 4.2 |
| 50 | 1.5 | 1 | 6.8 | 6.3 |
| 200 | 0.9 | 2.1 | 10.5 | 0.7 |
| Phenol red | ||||
| 20 | -2.4 | 3.8 | 7.8 | 6.4 |
| 40 | -1.4 | 2.1 | 6.6 | 6.1 |
| 60 | 1.6 | 3.1 | 14.4 | 3.3 |
- Citation: Song NN, Li QS, Liu CX. Intestinal permeability of metformin using single-pass intestinal perfusion in rats. World J Gastroenterol 2006; 12(25): 4064-4070
- URL: https://www.wjgnet.com/1007-9327/full/v12/i25/4064.htm
- DOI: https://dx.doi.org/10.3748/wjg.v12.i25.4064