Brief Report Open Access
Copyright ©The Author(s) 2001. Published by Baishideng Publishing Group Inc. All rights reserved.
World J Gastroenterol. Aug 15, 2001; 7(4): 587-592
Published online Aug 15, 2001. doi: 10.3748/wjg.v7.i4.587
Treatment of malignant digestive tract obstruction by combined intraluminal stent installation and intra-arterial drug infusion
Ai-Wu Mao, Zhong-Du Gao, Ting-Hui Jiang, Wei-Jun Jiang, Department of Interventional Radiology, Shanghai S. T, Luke’s Hospital, 768 Yu Yuan Road, Shanghai 200050, China
Jia-Yu Xu, Department of Gastroenterology Rui Jin Hospital, Shanghai Second Medical University
Ren-Jie Yang, Department of Tumor Hospital, Beijing Medical University
Xiang-Seng Xiao, Department of Imaging Chang Zheng Hospital, Shanghai Second Military Medical University
Author contributions: All authors contributed equally to the work.
Correspondence to: Ai-Wu Mao, Department of Interventional Radiology, Shanghai S.T, Luke’s Hospital, 768 Yu Yuan Road, Shanghai 200050, China. maw1@elong.com.
Telephone: 0086-21-62524259 Ext. 3397 Fax: 0086-21-62113884
Received: March 12, 2001
Revised: June 8, 2001
Accepted: June 15, 2001
Published online: August 15, 2001

Abstract

AIM: To study the palliative treatment of malignant obstrution of digestive tract with placement of intraluminal stent combined with intra-arterial infusion of chemotherapeutic drugs.

METHODS: A total of 281 cases of digestive tract malignant obstruction were given per oral (esophagus, stomach, duodenum and jejunum), per anal (colon and rectum) and percutaneous transhepatic (biliary) installation of metallic stent. Among them, 203 cases received drug infusion by cannulation of tumor supplying artery with Seldinger’s technique.

RESULTS: Altogether 350 stents were installed in 281 cases, obstructive symptoms were relieved or ameliorated after installation. Occurrence of restenotic obstruction was 8-43 weeks among those with intra-arterial drug infusion, which was later than 4-26 weeks in the group with only stent installation. The average survival time of the former group was 43 (3-105) weeks, which was significantly longer than 13 (3-24) weeks of the latter group.

CONCLUSION: Intraluminal placement of stent combined with intra-arterial infusion chemotherapy is one of the effective palliative therapies for malignant obstruction of the digestive tract with symptomatic as well as etiological treatment.

Key Words: digestive tract disease; treatment; stent; therapeutic embolization chemotherapy; infusion, local



INTRODUCTION

Intraluminal installation of stent in digestive tract is being more and more widely used[1-31]. Drug infusion via supplying artery and embolization therapy have been used in clinical practice as an effective way of suppressing the growth of malignant tumors[32-43]. But up to now there have been few reports of the combined use of the two in the treatment of malignant stenotic lesions[44,45]. We have used the combined therapy in cases of malignant stenosis of digestive tract and have obtained good results in relieving symptoms, improving quality of life and prolongation of survival time. We managed 281 cases from October 1996 to May 2000 and the therapeutic results are reported below.

MATERIAL AND METHODS
Patients

A total of 281 patients with malignant obstruction of digestive tract were treated. Among them, 182 were males and 99 females, age ranged from 20 to 93 years, with an average of 65 years. The cause of obstruction was stenosis or obstruction of the digestive tract by infiltration or pressure of the malignant tumor. All cases belonged to late stages of tumor, impossible for surgical resection. One hundred and seventy-seven cases had operative histories of primary tumor resection, with reconstruction of digestive tract, biliary endostomy, bypass drainage or laparatomy, etc, 6 had histories of four operations, 83 cases of one operation . The primary disease included carcinoma of esophagus, 79 cases; stomach cancer 55 cases; carcinoma of liver, 25 cases; carcinoma of pancreas, 53 cases; colorectal cancer, 39 cases; cholangiocarcinoma, 10 cases; and other carcinomas, 20 cases. Pathological types: adenocarcinoma, 96 cases; squamous cell carcinoma, 74 cases; and others, 111 cases. Among the 281 cases, site of stenosis and obstruction at esophagus, 119 cases; at stomach (including gastrointestinal stoma), duodenum and jejunum, 76 cases; colorectal segment, 28 cases; and biliary tract, 58 cases. Some cases had more than two sites of stenosis or obstruction. They were divided in to groups A and B by patient or close relative’s choice. Group A (203 cases) received treatment by installation of intraluminal stent combined with intra-arterial cannulation for drug infusion via supplying artery. Group B (78 cases) received only installation of intraluminal stent and again according to their choice supplemented with intravenous chemotherapy, radiotherapy or traditional Chinese medicinal treatment. Those with impaired liver and/or kidney function due to the cancer, or very poor general condition not suitable for intravenous chemotherapy and radiotherapy were advised to join group A. In group A, there were 132 males and 71 females, aged 20-93 years, averaging 61 years. Of them, 82 cases could not meet the requirements of routine radiotherapy and chemotherapy such as blood routine, liver and kidney function or abnormalities of some other tests. In group B, there were 50 males and 28 females, age ranged from 28-87 years, averaging 58 years. Fourteen cases could not meet the requirements of routine radiotherapy and chemotherapy. Karnofsky quality of life evaluation in group A was 10-80 (average 36.2) score and 20-80 (average 40.2) score in group B.

Metallic intraluminal stent

Woven type nickel-titanium alloy stent was mainly used. The tubular meshwork, the whole some structure somewhat like wallstent was woven by single fine threads of nickel-titanium alloy of 0.20 mm-0.32 mm in diameter. Membranous stent was coated with polyurethane or silica gel on the mesh of the stent main body. For biliary tract, straight-neted duct stent was used without trumpet ends. The diameter of the tube is 0.8 cm-1.6 cm, and the length 6 cm-10 cm. The stent used for esophagus, stomach, duodenum and jejunum is of the type with trumpet opening on one end or both ends. The proximal end is basin-trumpet in shape, and the distal end cup or mushroom in shape. The tubular diameter of the stent main body is 1.1 cm-1.5 cm at cervical segment, 1.8 cm-2.8 cm at thoracic and abdominal segment of the esophagus. At stomach body, it is 2.0 cm-2.5 cm, and at duodenum and jejunum 1.8 cm-2.0 cm; the length of the stent is 3.5 cm-14 cm. The stent for the use of colon and rectum has both ends of ball or mushroom shape trumpet opening. The tubular diameter of the stent main body is 2.0 cm-2.2 cm at transverse colon, 2.5 cm-2.8 cm at descending colon, and 2.5 cm-3.2 cm at sigmoid colon and rectum; the length of the stent is 8 cm-14 cm. The width of the trumpet opening of all stents is 0.4 cm-0.7 cm. Some stents are specially made for specific requirements. Other stents we have used are home made“Z” shape esophageal stent, Wallstent for biliary and esophageal use (Schineder) and Memotherm biliary stent (Agmidel).

Transporter and auxilliary instruments

Wallstent and Memotherm stents were provided with a disposable coaxial two duct type transporter. Home-made “Z” shape stent was fixed with a sheath tube type pusher. Home made biliary and esophageal stents for cervical segment were used together with a sheath tube type pusher of Cook Company. For other stents we used self-made posterior positioned coaxial three ducts type transporter. Other auxilliary instruments included 6F Corber transmitting catheter, 2600 mm long Torumo Radifocus guide wire, 2600 mm-3000 mm long soft head super-hard guide wire, 1300 mm long exchange catheter, bulb dilating catheter of 25 mm in diameter and double-channel imaging catheter made from used bulb catheters. Gastroscope, colonoscope, microwave or diathermic apparatus were also available.

Treatment modalities

Installation of intraluminal stent. Stent was placed perorally to esophagus, stomach, duodenum and jejunum. Radiopaque guide wire was inserted via gastroscope or perorally. The pusher attached with the stent was introduced by the guide wire so that the stent could be slowly released after passing through the stenosed segment. For the installation of stent in duodenum and jejunum, super-hard guide wire was introduced via exchange catheter, and the stent was put by the pusher introduced by the hard guide wire. Biliary stent was installed by percutaneous puncture and insertion method. The puncture needle was inserted percutaneously and transhepatically into biliary tract. Radifocus guide wire was introduced through the puncture needle along the intrahepatic biliary tract into the common bile duct, and then through the stenosed segment deep into the small intestine. Through exchange soft head hard guide wire, sheath tube or coaxial two ducts type transporter put the stent into the stenosed segment. Colonic and rectal stent was inserted through anus. Radifocus guide wire was inserted through the stenosed segment by the catheter or via colonoscope. Exchange catheter was introduced and replaced the super-hard guide wire. The hard guide wire introduced the coaxial two ducts type transporter that releases the stent.

Intra-arterial drug infusion

Two to eight days before the installation of the stent or 0 d-4 d after it, chemotherapeutic infusion via cannulation of the supplying artery of the tumor was given. The Seldinger’s technique was used. According to the primary lesion or the infiltration field of the metastatic site, the supplying artery of the tumor was chosen as the target artery. Generally, the main trunk of the supplying artery was chosen for cannulation or multiple target points were chosen for cannulation at one time. The target arteries chosen for cannulation are: external jugular artery, inferior thyroid artery, or subclavicular artery bronchial artery, esophageal propriae artery, intercostal artery, hepatic artery (or coeliac artery trunk), superior mesenteric artery, inferior mesenteric artery, internal iliac artery, etc. The perfusing drugs used with dosage calculated according to surface area of the body were epirubicin 25 mg·m2, carboplatin 200 mg·m2, 5-Fu 500 mg·m2 forming triad drug group for use. For patients with abnormal liver and/or kidney functions (all caused by the malignant factors), dosage will be decreased accordingly. For those patients having normal routine profiles with better general condition, VM26 50-100 mg·m2 was added. For those with impaired cardiac function, adriamycin was substituted by pirarubicin 300 mg·m2. For some suitable patients emulsified 40% lipiodol and chemotherapeutics were given for superselective emolization. Patients with arterial venous fistula were first given gelfoam strips to block the fistular tract and then drug infusion. The second treatment was administered three weeks afterwards, and the third treatment was given after another 3-5 weeks. From then on, the interval could be prolonged to 1.5-5 months.

RESULTS
Installation of stent (Table 1)
Table 1 Installation of stents.
SiteGroup A
Group B
Total
No. of casesNo. of stentsNo. of casesNo. of stentsNo. of casesNo. of stents
Esophagus81953849119144
Stomach, small intestine556421347698
Colon, rectum19209102830
Biliary tract485310255878
Total20323378116281350

A total of 350 stents were installed in 281 cases. Among them 144 were esophageal stents (23 in cervical segment, 69 in thoracic segment and 52 in abdominal segment of esophagus). Ninety-eight stents were put in stomach duodenum and jejunum (21 in gastric body and pyloric region, 22 in gastrointestinal anastomotic oriface, 49 in descending and horizontal part of duodenum and 6 in proximal jejunum); 30 in colon and rectum (9 in transverse colon, 5 in descending and 16 in sigmoid colon and rectum). Seventy-eight were biliary stents. Among the 144 esophageal stents, 142 were home-made woven type tubular mesh stents (127 with attached membrane and 15 without membrane), one was home-made “Z” type stent with attached membrane. There was one wallstent without membrane. Among 98 stents used in stomach, duodenum and jejunum, 97 were home made (35 with attached membrane, 62 without). One Wallstent without membrane was used. Thirty stents used in colon and rectom (20 with membrane and 10 without) and 71 of 78 biliary stents were all home made. There were 4 Wallstents and 3 Memotherm stents. Biliary stents were all without membrane. The distribution of stents installed in groups A and B are shown in Table 1.

Drug infusion (Table 2)
Table 2 Drug infusion.
SiteNInfusion (n)Total infusion timesMax. per caseMin. per caseAverage per case
Esophagus119813101223.83
Stomach, small intestine76552291414.16
Colon, rectum281939812.94
Biliary tract5848130923.65
Total2812037083.49

Group A (203 cases) had received cannulation of supplying artery with infusion of chemotherapeutics (a total of 708 times). The minimum was one time (9 cases) and maximum was 14 times (one case). The average time was 3.49. Table 2 shows different patients undergoing drug infusion. Among the nine cases receiving treatment only once, which was refused by their relatives in 5 cases, and discontinued due to deterioration of their general condition in 2 cases, and the remaining 2 cases died. Three out of the 203 cases had received lipiodol emulsion embolization for 7 times, 11 cases had gelfoam embolization for 18 times. Besides occational hematoma at the puncture site, few cases complained of pain at the site of drug infusion and embolization treatment and 37% of cases had reversible lowering of blood counts, and no other arterial interventional procedure related complication was noted.

Clinical symptomatic impro ement

Among 119 cases with installation of esophageal stent, 18 had stent in the cervical segment and they all could take low residue regular diet. In 101 cases with stent in the thoracicor abdominal segment, those with simple stenosis basically restored to normal meals. Among 13 patients with esophagotracheal or esophagothoracic fistula, 11 could take normal meals after complete obliteration of the fistular tract, one still had some irritating cough while eating. Another case was a patient who developed esophageal stenosis with esophagothoracic fistula after unilateral pneumonectomy. Four days after installation of stent and obliteration of the fistula, the patient developed obvious irritating cough during eating. Imaging demonstrated proximal orifice of the stent protruded into the thoracic cavity forming another fistular tract. Among 76 patients with stent in stomach, duodenum or jejunum, 71 restored to normal meals and 5 had the obstructive symptoms improved, but could only take liquid diet. Twenty-eight cases with stent in colon or rectum had immediate relief of intestinal obstructive symptoms after installation, one of them who had colonic pelvic fistula had no more exudative leakage from the fistula tract after the installation. A case of rectal vaginal fistula had much less fecal exudation from vagina after installation. In 58 cases with installation of stent into the biliary tract, jaundice was significantly decreased, 39 cases had serum bilirubin returned to normal within a week. Nineteen cases had serum bilirubin dropped below 70 mmol/L. Clinical symptomatic improvement were similar between groups A and B shortly after treatment. Among 82 cases in group A whose conditions could not reach the requirements of laboratory profiles for routine radiotherapy or chemotherapy, 46 cases fulfilled the requirements after two drug infusions. Among 14 cases of group B, only 3 cases approached the requirements after 1-2 months. As the disease progressed, the number of patients whose original profiles were normal but became abnormal when the disease got worse, was significantly larger in group B than in group A. Comparison of Karnofsky life quality evaluation between the two groups at 4-6 week after installation of stent showed that the average score in group A increased from 36.2 to 53.2, while in group B, from 40.2 to 46.2. There was significant difference between the two groups.

Maintenance of efficacy and survival time

In group B, 23 restenotic obstructions occurred 4-26 weeks after treatment in 15 (23.1%) cases. In group A, 29 (14.3%) had 38 restenotic obstructions 8-43 weeks after treatment (Table 3). The survival time in group A was 3-105 weeks, averaging 43 weeks, while 3-24 weeks in group B averaging only 13 weeks. The survival time of group A was more significantly prolonged than group B (Table 4).

Table 3 Maintenance of efficacy (groups A/B).
SitenRestenosis
Restenosis (wk)
nNo. of times
Esophagus81/3815/1020/1212-35/04-17
Stomach, small intestine55/2106/0407/0517-42/07-16
Colon, rectum19/0902/0002/0026-43/0
Biliary tract48/1006/0409/068-33/05-26
Total203/7829 (14.3)/15 (23.1)38/2308-43/04-26
Table 4 Comparison of survival time (groups A/B).
SitesCasesSurvival (n)Death (n)Survival (wk)
RangeAverage
Esophagus81/3823/0358/355-103/5-2036/14
Stomach, small intestine55/2109/0246/194-105/2-1738/11
Colon, rectom19/0902/0017/093-98/3-1333/08
Biliary tract48/1006/0142/096-54/3-2430/18
Total203/7840/06163/723-105/3-2443/13
DISCUSSION
Significance and technical difficulties

Digestive tract is the necessary passage of alimentation digestion, absorption and excretion of waste metabolites. Obstruction of digestive tract interferes with food intake, bowel movement, or causes obstructive jaundice. All these seriously affect the quality of life of the patients and even accelerate death. In 1983, Frimberger first reported the use of metallic stent to treat esophageal stenosis[46]. Domschke in 1990 successfully used self-expansible woven mesh type metallic stent to treat a case of esophageal malignant obstruction[47]. Thus it was made possible the relief of obstruction of digestive tract by non-surgical procedures. Karnel et al[48], Goldrn et al[49], Keymling et al[50] and others had respectively tried to use metallic intraluminal stent in treating colonic, biliary and duodenal obstruction. Their success had laid the basis of the expanded use of digestive tract intraluminal stent. As intraluminal installation of stent in digestive tract is a non-surgical method with mini-invasive technique to render the stenosed digestive tract becoming patent again, thus providing a new approach in the palliative treatment of digestive tract malignant obstruction. Comparing with the conventional surgical operation, treatment by intraluminal installation of stent has the characteristics of mini-invasion, fast, effect, good clinical sutclins and repeatablity of the procedure. This avoids the damage caused by surgical operation. For those with no indication for operation or too weak to stand the operation, treatment with intraluminal installation of stent can provide palliation to the patients with symptomatic relief and improved quality of life.

Compared with vascular lumen and other non-vascular lumens, the various lumens at different parts of the digestive tract have special histologic structures and functional characteristics. For example, the cervical segment of esophagus has strong contractive force and is very sensitive to foreign body. Duodenum and jejunum are quite distant from mouth, their lumens are tortuous with frequent peristalsis. Colon has a haustral structure with a strong group contractile force. The peculiar tissue structure and functional characteristics make the procedure of installation of intraluminal stent somewhat difficult. So, up to now, the clinical use of installation of digestive tract intraluminal stent is still limitted to esophagus and biliary tract. We have chosen nickel-titanium alloy in the form of single fine threads woven longitudinally and transversely into a flexible mesh tabular stent according to the common feature of digestive tract structure and function. For the installation of stent in the high position cervical segment of esophagus, we made tolerance dilatation test and used small caliber so as to ameliorate foreign body or pain sensation, thus succeeding in putting the stent in the cervical segment of esophagus. We used high hardness, small friction and elongation coefficient, not easily restored once deformed material, polytetrafluroethylene, to make coaxial duct and put it in between the external and internal ducts made of polyethylene, which is soft, easily to be restored with big friction force. The coaxial duct type transporter was made in this way that can be introduced into tortuous intestinal tube to release the coaxial duct type transporter of the stent. We also used endoscope to help the insertion of the guide wire. Super-hard guide wire helps enlarge the turning angle of the colonic loops. All these measures solve the difficulty encounted in the remote release of the stent. This not only increased the success rate of installation of duodenal and proximal jejunal intraluminal stent orally[11], but also facilitated the installation of stent at high level transverse colon via anal route[17]. At the same time, we selected big caliber with high degree hardness double bulb shaped or mush room shaped trumpet orifice stent. This not only increased the expanding force but also increased the compliance of the connecting segment between the terminal opening of the sent and the normal intestinal tract. The therapeutic effect of colonic and rectal stent installation was thus elevated and its complication reduced.

Drug infusion via supplying artery of tumor

Intraluminal stent treatment can build up the basis for the patients for further treatment by the relief of digestive tract obstructive symptoms and improvement of life quality of late tumor cases. The advanced patients with tumor can rarely tolerate the toxic or side effect of traditional radio-and/or chemotherapy. In fact, the sensitivity toward traditional radio- and chemotherapy in absolute majority of patients with solid tumor of digestive tract is rather poor. As chemotherapeutics have killing and injurious effect to most tumor cells, the difference of therapeutic effect is mainly determined by whether the drug in the target organ can reach effective antitumor blood drug concentration or not. The general effect of traditional chemotherapy makes it difficult to reach an effective blood drug concentration in the target organ of gastrointestinal tract at safe dosage. As a result, clinical efficacy is low, while toxic and side effects are severe. Interventional chemotherapy by drug infusion of supplying artery can make the blood drug concentration in the vascular network of the tumor area reach an effective antitumor level by relative safe dosage, thus decreasing toxic and side reactions and increasing therapeutic efficacy. Intraluminal installation of stent in combination with drug infusion of supplying artery can release obstruction, improve life quality and at the same time inhibit growth of the malignant tumor. In the present study, the average survival time of our group B patients was 13 weeks, close to that reported by Turegano-Fuentes et al[51], Cwikiel et al[52] and P Scott Mackie et al[53]. The average survival time was 44 weeks in group A, significantly longer than the former. The restenosis was also more significantly prolonged in group A than in group B. This showed that interventional chemotherapy by arterial cannulation can produce in certain extent inhibition of the malignant tumor growth by its therapeutic effect. In conclusion, intraluminal stent therapy in combination with intra-arterial cannulation of interventional chemotherapy can be considered as an effective therapy with regard to symptomatic and etiological treatment and should be used more widely in the near future.

Footnotes

Edited by Ma JY

References
1.  Nevitt AW, Vida F, Kozarek RA, Traverso LW, Raltz SL. Expandable metallic prostheses for malignant obstructions of gastric outlet and proximal small bowel. Gastrointest Endosc. 1998;47:271-276.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 79]  [Cited by in F6Publishing: 80]  [Article Influence: 3.1]  [Reference Citation Analysis (0)]
2.  Soetikno RM, Lichtenstein DR, Vandervoort J, Wong RC, Roston AD, Slivka A, Montes H, Carr-Locke DL. Palliation of malignant gastric outlet obstruction using an endoscopically placed Wallstent. Gastrointest Endosc. 1998;47:267-270.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 76]  [Cited by in F6Publishing: 75]  [Article Influence: 2.9]  [Reference Citation Analysis (0)]
3.  Wayman J, Bliss R, Richardson DL, Griffin SM. Self-expanding metal stents in the palliation of small bowel stenosis secondary to recurrent gastric cancer. Gastrointest Endosc. 1998;47:286-290.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 18]  [Article Influence: 0.7]  [Reference Citation Analysis (0)]
4.  Tejero E, Mainar A, Fernández L, Tobío R, De Gregorio MA. New procedure for the treatment of colorectal neoplastic obstructions. Dis Colon Rectum. 1994;37:1158-1159.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 188]  [Cited by in F6Publishing: 169]  [Article Influence: 5.6]  [Reference Citation Analysis (0)]
5.  Buffet C, Couderc T, Fritsch J, Choury A, Lefebvre JF, Marteau V, Ink O, Bonnel D, Liguory C, Etienne JP. [Palliative treatment by endoprosthesis of icterus caused by distal biliary tumoral obstruction]. Gastroenterol Clin Biol. 1993;17:629-635.  [PubMed]  [DOI]  [Cited in This Article: ]
6.  von Schönfeld J. Endoscopic retrieval of a broken and migrated esophageal metal stent. Z Gastroenterol. 2000;38:795-798.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 6]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
7.  Kim HC, Han JK, Kim TK, Do KH, Kim HB, Park JH, Choi BI. Duodenal perforation as a delayed complication of placement of an esophageal stent. J Vasc Interv Radiol. 2000;11:902-904.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 21]  [Cited by in F6Publishing: 23]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
8.  Sugimoto K, Hirota S, Imanaka K, Kawabe T, Matsumoto S, Sugimura K. Application of self-expanding metallic stents to malignant stricture following mechanically stapled esophagojejunostomy: report of two cases. Radiat Med. 2000;18:133-137.  [PubMed]  [DOI]  [Cited in This Article: ]
9.  Cornud F, Chrétien Y, Hélénon O, Casanova JM, Correas JM, Bonnel D, Méjean A, Moreau JF. Percutaneous incision of stenotic uroenteric anastomoses with a cutting balloon catheter: long-term results. Radiology. 2000;214:358-362.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 18]  [Cited by in F6Publishing: 18]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
10.  Mishima K, Sawada S, Tanigawa N, Okuda Y, Kobayashi M, Koyama T. Expandable metallic stent treatment for malignant colorectal strictures. Cardiovasc Intervent Radiol. 1999;22:155-158.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 10]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
11.  Nomori H, Horio H, Imazu Y, Suemasu K. Double stenting for esophageal and tracheobronchial stenoses. Ann Thorac Surg. 2000;70:1803-1807.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 54]  [Cited by in F6Publishing: 58]  [Article Influence: 2.4]  [Reference Citation Analysis (0)]
12.  Warren WH. Palliation of dysphagia. Chest Surg Clin N Am. 2000;10:605-623, x-xi.  [PubMed]  [DOI]  [Cited in This Article: ]
13.  Macdonald S, Edwards RD, Moss JG. Patient tolerance of cervical esophageal metallic stents. J Vasc Interv Radiol. 2000;11:891-898.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 51]  [Cited by in F6Publishing: 50]  [Article Influence: 2.1]  [Reference Citation Analysis (0)]
14.  Tanaka T, Maeda M, Uchida H, Yoshioka T, Matsuo Y, Makutani S, Yoshimura H, Kichikawa K, Ohishi H. Clinical results of the internally covered spiral Z stent for malignant esophagogastric obstruction and the reduction of stent migration. J Vasc Interv Radiol. 2000;11:771-776.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 4]  [Article Influence: 0.2]  [Reference Citation Analysis (0)]
15.  Mayoral W, Fleischer D, Salcedo J, Roy P, Al-Kawas F, Benjamin S. Nonmalignant obstruction is a common problem with metal stents in the treatment of esophageal cancer. Gastrointest Endosc. 2000;51:556-559.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 98]  [Cited by in F6Publishing: 103]  [Article Influence: 4.3]  [Reference Citation Analysis (0)]
16.  Zaragozano Guillén R, Galbe Sada R, Cobos Hernández Mf, Simón M, Antón A. Our experience with Wallstent self-expanding metal prostheses in 65 patients with malignant dysphagia. Rev Esp Enferm Dig. 1999;91:736-747.  [PubMed]  [DOI]  [Cited in This Article: ]
17.  Farkas PS, Farkas JD, Koenigs KP. An easier method to remove migrated esophageal Z-stents. Gastrointest Endosc. 1999;50:277-279.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 20]  [Cited by in F6Publishing: 21]  [Article Influence: 0.8]  [Reference Citation Analysis (0)]
18.  Vakil N, Bethge N. Plastic stents in the esophagus: is homemade really better? Am J Gastroenterol. 1999;94:1701-1702.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 2]  [Cited by in F6Publishing: 3]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]
19.  Conio M, Caroli-Bosc F, Demarquay JF, Sorbi D, Maes B, Delmont J, Dumas R. Self-expanding metal stents in the palliation of neoplasms of the cervical esophagus. Hepatogastroenterology. 1999;46:272-277.  [PubMed]  [DOI]  [Cited in This Article: ]
20.  Binkert CA, Ledermann H, Jost R, Saurenmann P, Decurtins M, Zollikofer CL. Acute colonic obstruction: clinical aspects and cost-effectiveness of preoperative and palliative treatment with self-expanding metallic stents--a preliminary report. Radiology. 1998;206:199-204.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 148]  [Cited by in F6Publishing: 143]  [Article Influence: 5.5]  [Reference Citation Analysis (0)]
21.  Abdel Wahab M, el-Ebiedy G, Sultan A, el-Ghawalby N, Fathy O, Gad el-Hak N, Abo Elenin A, Abo Zid M, Ezzat F. Postcholecystectomy bile duct injuries: experience with 49 cases managed by different therapeutic modalities. Hepatogastroenterology. 1996;43:1141-1147.  [PubMed]  [DOI]  [Cited in This Article: ]
22.  Hyodo T, Yoshida Y, Yamanaka T, Imawari M. Duodenal stenosis after endoscopic biliary metallic stent placement for malignant biliary stenosis. Gastrointest Endosc. 2000;52:64-66.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 9]  [Cited by in F6Publishing: 9]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
23.  Nakamura T, Kitagawa M, Takehira Y, Yamada M, Kawasaki T, Nakamura H. Polyurethane-covered Wallstents to recanalize Wallstents obstructed by tumor ingrowth from malignant common bile duct obstruction. Cardiovasc Intervent Radiol. 2000;23:161-164.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 12]  [Cited by in F6Publishing: 11]  [Article Influence: 0.5]  [Reference Citation Analysis (0)]
24.  Cheng YF, Lee TY, Sheen-Chen SM, Huang TL, Chen TY. Treatment of complicated hepatolithiasis with intrahepatic biliary stricture by ductal dilatation and stenting: long-term results. World J Surg. 2000;24:712-716.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 34]  [Cited by in F6Publishing: 35]  [Article Influence: 1.5]  [Reference Citation Analysis (0)]
25.  Camúñez F, Echenagusia A, Simó G, Turégano F, Vázquez J, Barreiro-Meiro I. Malignant colorectal obstruction treated by means of self-expanding metallic stents: effectiveness before surgery and in palliation. Radiology. 2000;216:492-497.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 185]  [Cited by in F6Publishing: 189]  [Article Influence: 7.9]  [Reference Citation Analysis (0)]
26.  Mauro MA, Koehler RE, Baron TH. Advances in gastrointestinal intervention: the treatment of gastroduodenal and colorectal obstructions with metallic stents. Radiology. 2000;215:659-669.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 158]  [Cited by in F6Publishing: 164]  [Article Influence: 6.8]  [Reference Citation Analysis (0)]
27.  Boorman P, Soonawalla Z, Sathananthan N, MacFarlane P, Parker MC. Endoluminal stenting of obstructed colorectal tumours. Ann R Coll Surg Engl. 1999;81:251-254.  [PubMed]  [DOI]  [Cited in This Article: ]
28.  Lee JG, Leung JW. The pitfall of relying on the abdominal radiograph to determine stent function after palliation of malignant colonic obstruction using a self-expanding metal stent. Am J Gastroenterol. 2000;95:2107-2109.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 1]  [Cited by in F6Publishing: 1]  [Article Influence: 0.0]  [Reference Citation Analysis (0)]
29.  Mainar A, De Gregorio Ariza MA, Tejero E, Tobío R, Alfonso E, Pinto I, Herrera M, Fernández JA. Acute colorectal obstruction: treatment with self-expandable metallic stents before scheduled surgery--results of a multicenter study. Radiology. 1999;210:65-69.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 146]  [Cited by in F6Publishing: 151]  [Article Influence: 6.0]  [Reference Citation Analysis (0)]
30.  de Gregorio MA, Mainar A, Tejero E, Tobío R, Alfonso E, Pinto I, Fernández R, Herrera M, Fernández JA. Acute colorectal obstruction: stent placement for palliative treatment--results of a multicenter study. Radiology. 1998;209:117-120.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 114]  [Cited by in F6Publishing: 112]  [Article Influence: 4.3]  [Reference Citation Analysis (0)]
31.  Wholey MH, Levine EA, Ferral H, Castaneda-Zuniga W. Initial clinical experience with colonic stent placement. Am J Surg. 1998;175:194-197.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 58]  [Cited by in F6Publishing: 56]  [Article Influence: 2.2]  [Reference Citation Analysis (0)]
32.  Homma H, Doi T, Mezawa S, Takada K, Kukitsu T, Oku T, Akiyama T, Kusakabe T, Miyanishi K, Niitisu Y. Related Articles, Books, LinkOut A novel arterial infusion chemo-therapy for the treatment of patients with advanced pancreatic carcinoma after vascular supply distribution via superselective embolization. Cancer. 2000;89:303-313.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in F6Publishing: 2]  [Reference Citation Analysis (0)]
33.  Yoshida H, Onda M, Tajiri T, Akimaru K, Uchida E, Arima Y, Mamada Y, Taniai N, Yamamoto K, Kaneko M. New techniques: splenic artery embolization followed by intraarterial infusion chemotherapy for the treatment of pancreatic cancer. Hepatogastroenterology. 1999;46:2024-2027.  [PubMed]  [DOI]  [Cited in This Article: ]
34.  Clark RA, Gallant TE. Bile duct strictures associated with hepatic arterial infusion chemotherapy. Gastrointest Radiol. 1987;12:148-151.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 13]  [Cited by in F6Publishing: 12]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
35.  Laughlin EH. Common duct stricture associated with hepatic artery infusion of FUDR. J Surg Oncol. 1986;31:56-59.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 4]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]
36.  Yoshida H, Onda M, Tajiri T, Uchida E, Arima Y, Mamada Y, Yamamoto K, Kaneko M, Terada Y, Kumazaki T. Experience with intraarterial infusion of styrene maleic acid neocarzinostatin (SMANCS)-lipiodol in pancreatic cancer. Hepatogastroenterology. 1999;46:2612-2615.  [PubMed]  [DOI]  [Cited in This Article: ]
37.  Beger HG, Gansauge F, Buchler MW, Link K. Hintraarterial adjuvant chemotherapy after pancreaticoduodenectomy for pancreatic cancer: significant reduction in occurrence of liver metastasis. World J Surg. 1999;23:946-949.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 69]  [Cited by in F6Publishing: 76]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
38.  Yoshida H, Onda M, Tajiri T, Akimaru K, Uchida E, Arima Y, Mamada Y, Taniai N, Yamamoto K, Kaneko M. New techniques: splenic artery embolization followed by intraarterial infusion chemotherapy for the treatment of pancreatic cancer. Hepatogastroenterology. 1999;46:2024-2027.  [PubMed]  [DOI]  [Cited in This Article: ]
39.  Gansauge F, Gansauge S, Link KH, Beger HG. p53 in relation to therapeutic outcome of locoregional chemotherapy in pancreatic cancer. Ann N Y Acad Sci. 1999;880:281-287.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 8]  [Cited by in F6Publishing: 8]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
40.  Naka T, Ashida K, Takahashi S, Kaneko T, Mizusawa K, Kaibara N. Effective TAE therapy using Lipiodol with epirubicin for liver metastases of nonfunctioning islet cell carcinoma of the pancreas. J Hepatobiliary Pancreat Surg. 1998;5:108-112.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 4]  [Cited by in F6Publishing: 4]  [Article Influence: 0.2]  [Reference Citation Analysis (0)]
41.  Rice D, Geller A, Bender CE, Gostout CJ, Donohue JH. Surgical and interventional palliative treatment of upper gastrointestinal malignancies. Eur J Gastroenterol Hepatol. 2000;12:403-408.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 6]  [Cited by in F6Publishing: 6]  [Article Influence: 0.3]  [Reference Citation Analysis (0)]
42.  Kröger JC, Bergmeister H, Hoffmeyer A, Ceijna M, Karle P, Saller R, Schwendenwein I, von Rombs K, Liebe S, Günzburg WH. Intraarterial instillation of microencapsulated cells in the pancreatic arteries in pig. Ann N Y Acad Sci. 1999;880:374-378.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 11]  [Cited by in F6Publishing: 11]  [Article Influence: 0.4]  [Reference Citation Analysis (0)]
43.  Martin DF, England RE, Tweedle DE. Radiological intervention in pancreatic cancer. Eur Radiol. 1998;8:9-15.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 3]  [Cited by in F6Publishing: 3]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]
44.  Mao AW, Gao ZD, Yang RJ, Cheng YS, Shang KZ, Xiao XS. Treatment of duodenal malignant stenosis using stent implantation combined with artrial chemotherapy. Chin J Radiol. 1998;32:655-657.  [PubMed]  [DOI]  [Cited in This Article: ]
45.  Mao AW, Gao ZD, Xiang XS, Tong L, Jiang TH, Fan H. Pallia-tive dual interventional therapy for late stage pancreatic malignancies. Chin J Gastroenterol and Hepatol. 2001;10:75-78.  [PubMed]  [DOI]  [Cited in This Article: ]
46.  Frimberger E. Expanding spiral--a new type of prosthesis for the palliative treatment of malignant esophageal stenoses. Endoscopy. 1983;15 Suppl 1:213-214.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 38]  [Cited by in F6Publishing: 39]  [Article Influence: 1.0]  [Reference Citation Analysis (0)]
47.  Domschke W, Foerster EC, Matek W, Rödl W. Self-expanding mesh stent for esophageal cancer stenosis. Endoscopy. 1990;22:134-136.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 86]  [Cited by in F6Publishing: 84]  [Article Influence: 2.5]  [Reference Citation Analysis (0)]
48.  Karnel F, Jantsch H, Niederle B. [Implantation of a metal stent in a malignant stenosis in a colon interposition]. Rofo. 1991;154:120-122.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 2]  [Cited by in F6Publishing: 3]  [Article Influence: 0.1]  [Reference Citation Analysis (0)]
49.  Gordon RL, Ring EJ, LaBerge JM, Doherty MM. Malignant biliary obstruction: treatment with expandable metallic stents--follow-up of 50 consecutive patients. Radiology. 1992;182:697-701.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 95]  [Cited by in F6Publishing: 97]  [Article Influence: 3.0]  [Reference Citation Analysis (0)]
50.  Keymling M, Wagner HJ, Vakil N, Knyrim K. Relief of malignant duodenal obstruction by percutaneous insertion of a metal stent. Gastrointest Endosc. 1993;39:439-441.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 52]  [Cited by in F6Publishing: 50]  [Article Influence: 1.6]  [Reference Citation Analysis (0)]
51.  Turégano-Fuentes F, Echenagusia-Belda A, Simó-Muerza G, Camuñez F, Muñoz-Jimenez F, Del Valle Hernandez E, Quintans-Rodriguez A. Transanal self-expanding metal stents as an alternative to palliative colostomy in selected patients with malignant obstruction of the left colon. Br J Surg. 1998;85:232-235.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 64]  [Cited by in F6Publishing: 60]  [Article Influence: 2.3]  [Reference Citation Analysis (0)]
52.  Cwikiel W, Andrén-Sandberg A. Malignant stricture with colovesical fistula: stent insertion in the colon. Radiology. 1993;186:563-564.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 30]  [Cited by in F6Publishing: 29]  [Article Influence: 0.9]  [Reference Citation Analysis (0)]
53.  Scott-Mackie P, Morgan R, Farrugia M, Glynos M, Adam A. The role of metallic stents in malignant duodenal obstruction. Br J Radiol. 1997;70:252-255.  [PubMed]  [DOI]  [Cited in This Article: ]  [Cited by in Crossref: 19]  [Cited by in F6Publishing: 17]  [Article Influence: 0.6]  [Reference Citation Analysis (0)]