Lord AC, Riss S. Is the type of insufflation a key issue in gastro-intestinal endoscopy? World J Gastroenterol 2014; 20(9): 2193-2199 [PMID: 24605018 DOI: 10.3748/wjg.v20.i9.2193]
Corresponding Author of This Article
Stefan Riss, MD, PD, FRCS, Department of General Surgery, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. stefan.riss@meduniwien.ac.at
Research Domain of This Article
Gastroenterology & Hepatology
Article-Type of This Article
Topic Highlight
Open-Access Policy of This Article
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Amy C Lord, Department of General Surgery, Basingstoke and North Hampshire Hospital, Basingstoke, Hampshire RG24 9NA, United Kingdom
Stefan Riss, Department of General Surgery, Medical University of Vienna, A-1090 Vienna, Austria
ORCID number: $[AuthorORCIDs]
Author contributions: Lord AC and Riss S contributed to conception, design, acquisition and interpretation of data; All authors revised the article and approved the final version.
Correspondence to: Stefan Riss, MD, PD, FRCS, Department of General Surgery, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria. stefan.riss@meduniwien.ac.at
Telephone: +43-1-404005621 Fax: +43-1-404006932
Received: October 16, 2013 Revised: December 18, 2013 Accepted: January 19, 2014 Published online: March 7, 2014 Processing time: 140 Days and 17.3 Hours
Abstract
Endoscopic procedures continue to play an emerging role in diagnosing and treating upper and lower gastrointestinal (GI) disorders. In particular, the introduction of colonoscopy in bowel cancer screening has underlined its promising role in decreasing the incidence of colorectal cancer and reducing tumour related mortality. To achieve these goals patients need to contemplate endoscopic examinations as painless and fearless procedures. The use of carbon dioxide (CO2) as an alternative insufflation gas in comparison to air has been considered as an essential key to improving patients’ acceptance in undergoing endoscopic procedures. CO2 is absorbed quickly through the bowel mucosa causing less luminal distension and potentially less abdominal pain. However, its exact role has not been defined completely. In particular, the beneficial use of CO2 in upper GI endoscopy and in sedated patients is still conflicting. In the present review, we aimed to assess the current evidence for using CO2 in endoscopy and to evaluate its potential role in the future.
Core tip: With the increasing use of gastrointestinal endoscopy, especially for screening in an asymptomatic population, increasing the tolerability of the procedure is of paramount importance. Our review summarizes evidence that carbon dioxide (CO2) insufflation can reduce both pain and bloating in colonoscopy and endoscopic retrograde cholangiopancreatography although the evidence in gastroscopy is still lacking. Despite established safety concerns about hypercapnia, significant harm has never been demonstrated in the literature. Patients thought to be at higher risk of hypercapnia need to be included in more studies to demonstrate that CO2 insufflation is safe in an unselected screening population but early evidence is encouraging.
Citation: Lord AC, Riss S. Is the type of insufflation a key issue in gastro-intestinal endoscopy? World J Gastroenterol 2014; 20(9): 2193-2199
In the last decade, endoscopy has become an essential diagnostic and therapeutic instrument in daily clinical practice. As a consequence, the number of endoscopic examinations has increased continuously, in particular, as a result of constant efforts to improve patient’s acceptance and compliance to participate in bowel cancer screening programs. However, some patients still have a fear of undergoing colonoscopy, as they associate it with considerable pain and discomfort.
A number of studies aimed to investigate how to ease abdominal symptoms in lower and upper gastrointestinal (GI) endoscopy[1]. The introduction of moderate or deep sedation has certainly been an essential step to increase its attractiveness and to reduce the anxiety and concerns of the patients[2]. Recent evidence demonstrates that sedation can be safely administered in colonoscopy without increasing the risk of respiratory or abdominal complications[3].
Another technique that has emerged in the last few years is the use of carbon dioxide (CO2) as an alternative insufflation gas. CO2 is rapidly absorbed by the intestinal mucosa and easily expired through the respiratory tract, with the potential advantage of reducing the duration of large bowel distension. However, there have also been concerns as whether CO2 results in a raise in arterial pressure of CO2 (pCO2) leading to cardiac or respiratory compromise[4].
Notably, several studies revealed promising results with significantly less abdominal pain during and after endoscopic procedures by using CO2 compared to air insufflation, which is still considered the standard gas to insufflate the bowel[5-7]. In addition, in upper GI endoscopy the use of CO2 gas remains conflicting in the current literature and convincing evidence is still missing to warrants its routine use[8]. It is also debatable whether the use of CO2 is still beneficial in patients, who are deeply sedated during the procedure.
In the present review, we aimed to assess the current evidence for the use of CO2 insufflation during diagnostic and therapeutic endoscopic procedures and to define its role in the future.
LOWER GI ENDOSCOPY
A high number randomised controlled trials comparing endoscopic insufflation with either CO2 or air were conducted in the last decade (Table 1). Interestingly, no studies to date have noted any technical disadvantages when using CO2 insufflation; insertion and withdrawal times, caecal intubation rates and complication rates are comparable or even superior in favour of CO2[9]. The volume of gas used has also been compared in several studies and no difference has been found when using CO2 compared to air[10].
Table 1 Studies comparing carbon dioxide and air insufflation in colonoscopy.
Greater increase in waist circumference in air group
The primary outcome measure in the majority of studies was pain, as measured using a visual analogue scale (VAS). Findings have consistently shown lower pain scores when CO2 insufflation was used in contrast to air, although some studies have shown a peak difference in pain score during the procedure or shortly after whereas others have shown evidence of a more delayed effect several hours after the procedure[7,11,12]. There is considerable heterogeneity between studies in the time intervals at which pain was measured.
Several studies have attempted to assess the degree of abdominal bloating objectively post procedure by assessing either the degree of colonic distension present on abdominal radiograph or the changes in waist circumference post procedure[7,11,13,14]. Findings have consistently demonstrated less distension in the group undergoing CO2 insufflation. The differences were marked with very little overlap between groups. For example Sumanac found that 71% of patients had large bowel dilatation of > 6 cm 1 h after colonoscopy with air insufflation compared with only 4% in the CO2 group[7].
Iida et al[15] investigated patients having CO2 compared to air insufflation colonoscopies and measured their levels of salivary alpha-amylase (SAA) as an objective maker of stress[15]. SAA levels increased as a result of colonoscopy in both groups as expected but the rise was significantly higher in the air group than the CO2 group. VAS scores were also measured however and there was no significant difference between the groups.
Sedation
Available studies used a wide range of sedation methods from no sedation to deep sedation with agents such as propofol. There has been some question as to whether the potential benefits of reduced pain with CO2 insufflation may be lost when deep sedation is used. The evidence would point to the contrary however with the majority of studies showing benefits lasting beyond the time that the sedation would have worn off[5,7,11,16,17]. Riss et al[5] used deep sedation and observed the greatest improvement in pain scores between 15 min and 6 h post-procedure showing that there is still a potential benefit.
Effects on screening
Making colonoscopy more comfortable is an issue of particular concern when considering bowel cancer screening programmes where asymptomatic patients are voluntarily undergoing the procedure with no guaranteed benefit. Several studies have addressed patients’ feelings about undergoing further colonoscopies when comparing air and CO2 insufflation to determine whether a more comfortable procedure would increase compliance with ongoing screening. The results showed a high level of satisfaction with the procedure, with the vast majority of patients reporting that they would be happy to go ahead with a repeat colonoscopy if necessary and would recommend it to others[5,12]. Geyer et al[17] found that overall satisfaction was slightly higher in the CO2 group (9.6 vs 9.3 on a VAS) however other studies have found no significant difference between the air and CO2 groups[5,12,17]. This does not strongly support the hypothesis that the use of CO2 could improve compliance with screening programmes.
CO2 insufflation only during scope withdrawal
There has been recent interest in whether using CO2 insufflation only for the withdrawal phase of colonoscopy retains the same benefits of reduced pain and distension as when CO2 is used for the entire procedure. Chen et al[18] and Hsu et al[19] both found that there was no difference in pain score when CO2 was used only for withdrawal[18,19].
Given that there seem to be no proven disadvantages in using CO2 for the entire procedure it is unclear what advantage would be offered by using air for insertion then changing to CO2 mid-procedure. One would assume that using two insufflation systems for each patient would have negative implications in terms of both time and cost.
UPPER GI ENDOSCOPY, ENDOSCOPIC RETROGRADE CHOLANGIOPANCREATOGRAPHY AND ENDOSCOPIC RESECTION PROCEDURES
There is increasing interest in the use of CO2 insufflation in gastric and oesophageal endoscopic submucosal resection procedures as well as endoscopic retrograde cholangiopancreatography (ERCP) where lengthy procedures may be necessary and abdominal pain from small bowel distension may be significant. There have been no studies looking at CO2 insufflation solely for gastroscopy without endoscopic surgery, ERCP or consecutive colonoscopy, presumably because post procedural pain is less of a problem than with colonoscopy.
A meta-analysis of 7 high quality RCTs (including a total of 756 patients) comparing CO2 to air insufflation in ERCP was carried out by Shi et al[20]. The authors found that there was a significant reduction in abdominal pain at 1, 3 and 6 h post procedure when CO2 was used although at 24 h there was no significant difference. There was no difference in the procedure time but a borderline reduction in complications was found in the CO2 group (pooled OR = 0.51; 95%CI: 0.27-0.97, P = 0.04). Further similar meta-analyses have been carried out by Cheng et al[21] and Wu et al[22] (Table 2) with similar findings[21,22]. There may be particular advantages for less experienced endoscopists when using CO2 insufflation as small bowel distension can make the procedure technically more difficult: Muraki et al[23] used physiological parameters and complications as outcome measures when ERCP was being carried out by non-expert endoscopists and found CO2 insufflation resulted in less physiological stress and borderline lower complications when compared to air.
Table 2 Summary of studies comparing the type of insufflation in endoscopic retrograde cholangiopancreatography.
Less evidence of physiological stress in CO2 group
Borderline lower complications in CO2 group
Only a small number of studies have investigated the use of CO2 insufflation for endoscopic resection procedures so far. The majority have concentrated on safety rather than pain scores[24,25]. Maeda et al[26] found that there was less gas present in the GI tract (assessed on CT scan) after CO2 insufflation but no difference in VAS scores or complication rates.
SAFETY CONCERNS
There have been established concerns that the use of CO2 insufflation may increase the systemic partial pCO2 and put strain on the respiratory system in trying to eliminate this. Hypercapnia can have a range of physiological effects in addition to respiratory stimulation including direct and indirect effects (via stimulation of the sympathetic nervous system). Predominantly the effects are cardiovascular, including peripheral vasoconstriction and tachycardia, and neurological, including confusion and reduced consciousness. For this reason the majority of RCTs have excluded large groups of patients such as those with cardiac or respiratory disease, those taking opiate analgesia and those known to have high baseline pCO2 levels. Several studies have attempted to quantify the effects on blood CO2 by measuring this either transcutaneously, with end-tidal CO2 or blood sampling[16,27].
Bretthauer found no difference in ETCO2 in unsedated patient undergoing colonoscopy, in fact CO2 levels fell during the procedure in both groups[16]. In patients undergoing sedated colonoscopy, particularly in deep sedation, an increase in CO2 has been found during the procedure but this was equally true for both air and CO2 groups and was likely to be due to respiratory depression due to sedation rather than the reabsorption of CO2 from the colon[28]. One potential limitation of many of these studies is the unreliability of indirect CO2 measurement with transcutaneous or end tidal CO2 measurement. Serial arterial blood gases may be more accurate but it was felt that this would be unacceptable to patients and therefore has not been widely used in studies so far.
For ERCP, safety data was analyzed in three of the RCTs. In two studies using sedation there was no difference in pCO2 between the two groups but in a single study which carried out ERCP under general anaesthetic with endotracheal intubation there were significantly higher pCO2 levels in the CO2 insufflation group, although this was easily compensated for by hyperventilation[29-31]. All RCTs excluded patients with COPD although some only excluded patients with severe COPD evidenced by known CO2 retention or use of home oxygen. The rise in CO2 in patients having ERCP under general anaesthetic may be of concern as it implies that patients probably hyperventilate to some degree to remove the extra CO2. When they were anaesthetized this didn’t happen and CO2 rose. In patients with significant respiratory disease it may be that they are not able to cope with this compensation but only small numbers of patients have been studied so far.
Suzuki et al[24] monitored the arterial pCO2 in 100 patients undergoing prolonged CO2 insufflation for endoscopic submucosal dissection under general anaesthesia and found that although pCO2 rose to a median peak of 39 mmHg, this was acceptable and easily controllable and there was little correlation with procedure time. There was no air group for comparison. Takano et al[25] carried out a crossover trial and found no difference in pCO2 when air or CO2 insufflation was being used.
So far the majority of studies have found no significant increase in pCO2 in patients undergoing endoscopy with CO2 insufflation compared to air insufflation. Although CO2 insufflation has been shown to be safe in all studies to date, the exclusion of patients with respiratory disease in many studies means that these results cannot be applied to all patient groups and the participants are not representative of a screening population. Later studies have addressed this by removing any exclusion criteria. Geyer found that there was no significant rise above normal CO2 levels in an unselected population[17]. Changing over to use CO2 as standard for endoscopy would mean using this in high risk groups where less safety data is available but there is no evidence so far to suggest that exclusion of particular patient groups is necessary.
Current sedation and monitoring guidelines are summarized by Lichtenstein et al[32]. They advocate the use of opiates and benzodiazepine for moderate sedation and monitoring with clinical observation, pulse oximetry and non-invasive blood pressure measurement. The use of capnography or other advanced monitoring was not advocated for patients undergoing moderate sedation. In ‘‘low risk’’ patients as included in most studies there were not significant problems with hypercapnia therefore this level of monitoring is likely to be adequate. In ‘‘high risk’’ patients more at risk of hypercapnia or respiratory complications further monitoring could be considered due to the current paucity of evidence in this population.
COST ANALYSIS
Yamano et al[27] estimated that the use of CO2 in their unit increased the cost of each colonoscopy by 2.5%. This cost estimation was related to the gas used and the initial cost of a CO2 insufflation system also needs to be taken into account by units considering changing to CO2 rather than air insufflation. This may be offset in the longer term by less use of sedation, potentially shorter stays following the procedure and a lower readmission rate.
A cost analysis was carried out as part of the meta-analysis by Cheng et al[21] comparing air and CO2 insufflation in ERCP. They analysed equipment, hospital, radiology and physician costs and found no significant cost difference between the two methods.
CONCLUSION
In the light of available RCT´s and subsequent meta-analyses, several conclusions can be drawn with potential clinical relevance. The use of CO2 in colonoscopy has significant advantages compared to air insufflation. Especially, abdominal pain and bloating during and after the procedure were reduced in the CO2 insufflation group in the vast majority of published studies. Notably, this positive effect was also detectable in patients, who were deeply sedated during endoscopy. The question of whether CO2 insufflation results in improved patient satisfaction was found to be controversial, however, it is assumable that patients with less pain also tend to repeat or recommend colonoscopy more likely. The concern that CO2 increases the risk of complications due to elevated systemic partial pressure of CO2 has not been studied intensively, but recent data support its widespread use in an unselected population.
In contrast, the use of CO2 in upper GI endoscopy is not clearly defined and further well designed studies are mandatory to assess it exact role in this field.
Footnotes
P- Reviewers: Andus T, Gentili A, Tang D S- Editor: Ma YJ L- Editor: A E- Editor: Liu XM
Sumanac K, Zealley I, Fox BM, Rawlinson J, Salena B, Marshall JK, Stevenson GW, Hunt RH. Minimizing postcolonoscopy abdominal pain by using CO(2) insufflation: a prospective, randomized, double blind, controlled trial evaluating a new commercially available CO(2) delivery system.Gastrointest Endosc. 2002;56:190-194.
[PubMed] [DOI][Cited in This Article: ]
Stevenson GW, Wilson JA, Wilkinson J, Norman G, Goodacre RL. Pain following colonoscopy: elimination with carbon dioxide.Gastrointest Endosc. 1992;38:564-567.
[PubMed] [DOI][Cited in This Article: ]
Fernández-Calderón M, Muñoz-Navas MÁ, Carrascosa-Gil J, Betés-Ibáñez MT, de-la-Riva S, Prieto-de-Frías C, Herráiz-Bayod MT, Carretero-Ribón C. Carbon dioxide vs. air insufflation in ileo-colonoscopy and in gastroscopy plus ileo-colonoscopy: a comparative study.Rev Esp Enferm Dig. 2012;104:237-241.
[PubMed] [DOI][Cited in This Article: ]
Seo EH, Kim TO, Park MJ, Kim HJ, Shin BC, Woo JG, Heo NY, Park J, Park SH, Yang SY. The efficacy and safety of carbon dioxide insufflation during colonoscopy with consecutive esophagogastroduodenoscopy in moderately sedated outpatients: a randomized, double-blind, controlled trial.J Clin Gastroenterol. 2013;47:e45-e49.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 13][Cited by in F6Publishing: 8][Article Influence: 0.7][Reference Citation Analysis (0)]
Iida T, Okamura S, Kakizaki S, Sagawa T, Zhang Y, Kobayashi R, Masuo T, Mori M. Carbon dioxide insufflation reduces the discomfort due to colonoscopy as objectively analyzed by salivary stress markers.Acta Gastroenterol Belg. 2013;76:219-224.
[PubMed] [DOI][Cited in This Article: ]
Bretthauer M, Thiis-Evensen E, Huppertz-Hauss G, Gisselsson L, Grotmol T, Skovlund E, Hoff G. NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy.Gut. 2002;50:604-607.
[PubMed] [DOI][Cited in This Article: ]
Wu J, Hu B. Carbon dioxide insufflation versus air insufflation during endoscopic retrograde cholangiopancreatography: a meta-analysis.J Interv Gastroenterol. 2013;3:37-42.
[PubMed] [DOI][Cited in This Article: ]
Muraki T, Arakura N, Kodama R, Yoneda S, Maruyama M, Itou T, Watanabe T, Maruyama M, Matsumoto A, Kawa S. Comparison of carbon dioxide and air insufflation use by non-expert endoscopists during endoscopic retrograde cholangiopancreatography.Dig Endosc. 2013;25:189-196.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 7][Cited by in F6Publishing: 9][Article Influence: 0.8][Reference Citation Analysis (0)]
Takano A, Kobayashi M, Takeuchi M, Hashimoto S, Mizuno K, Narisawa R, Aoyagi Y. Capnographic monitoring during endoscopic submucosal dissection with patients under deep sedation: a prospective, crossover trial of air and carbon dioxide insufflations.Digestion. 2011;84:193-198.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 14][Cited by in F6Publishing: 14][Article Influence: 1.2][Reference Citation Analysis (0)]
Maeda Y, Hirasawa D, Fujita N, Obana T, Sugawara T, Ohira T, Harada Y, Yamagata T, Suzuki K, Koike Y. A prospective, randomized, double-blind, controlled trial on the efficacy of carbon dioxide insufflation in gastric endoscopic submucosal dissection.Endoscopy. 2013;45:335-341.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 24][Cited by in F6Publishing: 34][Article Influence: 3.4][Reference Citation Analysis (0)]
Yamano HO, Yoshikawa K, Kimura T, Yamamoto E, Harada E, Kudou T, Katou R, Hayashi Y, Satou K. Carbon dioxide insufflation for colonoscopy: evaluation of gas volume, abdominal pain, examination time and transcutaneous partial CO2 pressure.J Gastroenterol. 2010;45:1235-1240.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 47][Cited by in F6Publishing: 56][Article Influence: 4.0][Reference Citation Analysis (0)]
Luigiano C, Ferrara F, Pellicano R, Fabbri C, Cennamo V, Bassi M, Ghersi S, Billi P, Polifemo A, Festa C. Carbon dioxide insufflation versus air insufflation during endoscopic retrograde cholangiopancreatography under general anesthesia.Minerva Med. 2011;102:261-269.
[PubMed] [DOI][Cited in This Article: ]
Liu X, Liu D, Li J, Ou D, Zhou Z. [Safety and efficacy of carbon dioxide insufflation during colonoscopy].Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2009;34:825-829.
[PubMed] [DOI][Cited in This Article: ]
Kuwatani M, Kawakami H, Hayashi T, Ishiwatari H, Kudo T, Yamato H, Ehira N, Haba S, Eto K, Kato M. Carbon dioxide insufflation during endoscopic retrograde cholangiopancreatography reduces bowel gas volume but does not affect visual analogue scale scores of suffering: a prospective, double-blind, randomized, controlled trial.Surg Endosc. 2011;25:3784-3790.
[PubMed] [DOI][Cited in This Article: ][Cited by in Crossref: 16][Cited by in F6Publishing: 18][Article Influence: 1.4][Reference Citation Analysis (0)]