1
|
Miller A, Anderson JC. Strategies, Technologies, and Tips for Successful Cecal Intubation. J Clin Gastroenterol 2025; 59:16-23. [PMID: 39495781 DOI: 10.1097/mcg.0000000000002096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2024] [Accepted: 10/02/2024] [Indexed: 11/06/2024]
Abstract
Successful cecal intubation is crucial in ensuring a complete evaluation of the colonic mucosa. Although completion of colonoscopies should be successful in close to 100% of all examinations in the hands of experienced gastroenterologists, there are some patients with colons which can be difficult to navigate. Factors such as older age, presence of diverticular disease, as well as high or low body mass index can present challenges for endoscopists. Challenges can be divided into those that are left sided and are associated with severe angulations of the colon versus those that are right sided and present as redundant colons. Both require different strategies to achieve completion. This review will cover methods, technologies as well the evolution of colonoscope insertion tubes which can help in navigating colons, especially those that are challenging. There will also be a discussion about basic principles and techniques that should be employed in all colonoscopies.
Collapse
Affiliation(s)
| | - Joseph C Anderson
- University of Connecticut, School of Medicine
- Geisel School of Medicine at Dartmouth, Hanover, NH
- White River Junction VAMC, White River Junction, VT
- NH Colonoscopy Registry, Lebanon, NH, USA
| |
Collapse
|
2
|
Al-Toma A, Oude Hergelink DM, Tenthof van Noorden J, Koornstra JJ. Prospective evaluation of the motorized spiral enteroscope for previous incomplete colonoscopy. Endosc Int Open 2022; 10:E1112-E1117. [PMID: 36238532 PMCID: PMC9552671 DOI: 10.1055/a-1869-2541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 05/30/2022] [Indexed: 11/23/2022] Open
Abstract
Background and study aims A significant percentage of colonoscopies remain incomplete because of failure to intubate the cecum. The motorized spiral enteroscope (MSE) technique, originally developed for deep small bowel enteroscopy, may be an effective alternative technique in cases of incomplete examination of abnormally long colons (dolichocolon). We prospectively evaluated the success rate of cecal intubation, safety and the therapeutic consequences of using MSE after incomplete conventional colonoscopy. Patients and methods A total of 36 consecutive patients with an indication for diagnostic and/or therapeutic colonoscopy were prospectively enrolled in this multicenter trial. All patients had undergone at least one incomplete colonoscopy attributed to abnormally long colons. Patients with incomplete colonoscopy due to stenosis were excluded. Results Twenty-two men and 14 women (median age 66 years, range 35-82) were enrolled. Median procedure time was 30 minutes (range 16-50). Cecal intubation rate was 100 % and median cecal intubation time was 10 minutes (range 4-30). Abnormalities, mostly neoplastic lesions, were detected in 23 of 36 patients, corresponding to a diagnostic yield of 64 %. All these findings were in the right side of the colon and had not been described by the antecedent incomplete coloscopy. No adverse events occurred. Conclusions In case of a difficult and long colon, MSE is safe and effective for diagnostic and therapeutic colonoscopy. It may provide an attractive solution to accomplish completeness of previous incomplete colonoscopies in these patients.
Collapse
Affiliation(s)
- Abdulbaqi Al-Toma
- Department of Gastroenterology and hepatology, St. Antonius hospital, Nieuwegein, the Netherlands
| | - Dorien M. Oude Hergelink
- Department of Gastroenterology & Hepatology, University Medical Centre Groningen, University of Groningen, The Netherlands
| | | | - Jan Jacob Koornstra
- Department of Gastroenterology & Hepatology, University Medical Centre Groningen, University of Groningen, The Netherlands
| |
Collapse
|
3
|
Bhat S, Wells CI, Tan J, Bissett IP, Lill M. Colonoscopy quality indicators in patients with and without prior colonic resection: A single-centre prospective comparative study. Colorectal Dis 2021; 23:1755-1764. [PMID: 33714237 DOI: 10.1111/codi.15628] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 02/24/2021] [Accepted: 03/03/2021] [Indexed: 02/08/2023]
Abstract
AIM Effective colonoscopy relies on meeting rigorous quality control thresholds. Some earlier studies evaluating colonoscopy key performance indicators (KPIs) have excluded patients who have previously undergone colonic resection (i.e., they have a nonintact colon); such patients also deserve high-quality colonoscopy. This study aimed to compare colonoscopy KPIs between patients with nonintact and intact colons. METHOD Consecutive colonoscopies performed at Whanganui Hospital (New Zealand) between September 2016 and March 2020 were included. The primary outcome was the caecal or ileal intubation rate (CIIR). Secondary outcomes were the adenoma detection rate (ADR), polyp detection rate (PDR), colonoscope withdrawal time (CWT) and caecal or ileal intubation time (CIIT). RESULTS In total, 3017 colonoscopies were performed: 322 in nonintact colons and 2695 in intact colons. CIIR was significantly higher in nonintact than in intact colons (98.4% vs. 95.0%; P = 0.0086). When all colonoscopies were included, the CIIR was 95.4%; this value decreased to 95.0% when nonintact colonoscopies were excluded. However, the ADR (39.9% vs. 38.8%; P = 0.77) and PDR (58.4% vs. 59.1%; P = 0.86) were similar for both nonintact and intact colons. CWT (P < 0.0001) and CIIT (P < 0.0001) were significantly shorter in participants with nonintact colons. CONCLUSION The CIIR exceeded recommended targets and was 3.4% higher in patients with nonintact than intact colons. Patients with nonintact colons comprise a small proportion of the overall colonoscopy cohort and it is unlikely that this small difference is relevant for most endoscopists or endoscopy units. The ADR and PDR were similar among patients with nonintact and intact colons, despite nonintact colonoscopies being significantly quicker. Patients with nonintact colons deserve high-quality colonoscopy and therefore their KPIs should be included in colonoscopy performance reports.
Collapse
Affiliation(s)
- Sameer Bhat
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Cameron I Wells
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Jeffrey Tan
- Department of Surgery, Whanganui Hospital, Whanganui District Health Board, Whanganui, New Zealand
| | - Ian P Bissett
- Department of Surgery, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Marianne Lill
- Department of Surgery, Whanganui Hospital, Whanganui District Health Board, Whanganui, New Zealand
| |
Collapse
|
4
|
Kadhim I, Choi J. Extension Mechanism of a Flexible End for Colonoscopy. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2020; 13:245-258. [PMID: 32982491 PMCID: PMC7508561 DOI: 10.2147/mder.s265313] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 08/25/2020] [Indexed: 11/24/2022] Open
Abstract
Introduction The significance of the distal tip extension mechanism (DTEM) arises when the insertion tube of the colonoscope is no longer able to move further inside the colon, and when a longer insertion tube is needed. The main focus of this research is to investigate the development of a novel distal tip extension mechanism (DTEM). Methods To characterize the performance of the DTEM, the ability of the DTEM to extend the distal tip of the colonoscope 16 cm is investigated. To determine the maximum number of turns that the extension knob needs to make in order to move the distal tip 16 cm, the DTEM is used to displace the distal tip in different colon configurations using the silicon tube of a colonoscopy training model (CTM). The experimentally collected data was presented and discussed to characterize the performance of the DTEM. Results The results showed that the DTEM is able to extend the distal tip 16 cm while the colon is in various configurations. Additionally, the impact of implanting the DTEM on the flexibility of the insertion tube was determined. Discussion The results of this research suggest that the DTEM will be an effective tool to help colonoscopists performing better colonoscopies.
Collapse
Affiliation(s)
| | - Junghun Choi
- Department of Mechanical Engineering, Georgia Southern University, Statesboro, GA, USA
| |
Collapse
|
5
|
Baltes P, Bota M, Albert J, Philipper M, Hörster HG, Hagenmüller F, Steinbrück I, Jakobs R, Bechtler M, Hartmann D, Neuhaus H, Charton JP, Mayershofer R, Hohn H, Rösch T, Groth S, Nowak T, Wohlmuth P, Keuchel M. PillCamColon2 after incomplete colonoscopy - A prospective multicenter study. World J Gastroenterol 2018; 24:3556-3566. [PMID: 30131662 PMCID: PMC6102503 DOI: 10.3748/wjg.v24.i31.3556] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 07/18/2018] [Accepted: 07/21/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield.
METHODS This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.
RESULTS Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda.
CONCLUSION Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
Collapse
Affiliation(s)
- Peter Baltes
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| | - Marc Bota
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| | - Jörg Albert
- Department of Internal Medicine I, Klinikum der JW. Goethe Universität, Frankfurt 60590, Germany
| | | | | | | | - Ingo Steinbrück
- 1st Medical Department, Asklepios Klinikum Altona, Hamburg 22763, Germany
| | - Ralf Jakobs
- Medical Clinic C, Klinikum der Stadt Ludwigshafen, Ludwigshafen 67063, Germany
| | - Matthias Bechtler
- Medical Clinic C, Klinikum der Stadt Ludwigshafen, Ludwigshafen 67063, Germany
| | - Dirk Hartmann
- Clinic for Internal Medicine, Sana Klinikum Lichtenberg, Berlin 10365, Germany
| | - Horst Neuhaus
- Clinic for Internal Medicine, Evangelisches Krankenhaus, Düsseldorf 40217, Germany
| | - Jean-Pierre Charton
- Clinic for Internal Medicine, Evangelisches Krankenhaus, Düsseldorf 40217, Germany
| | | | - Horst Hohn
- Schwerpunktpraxis Gastroenterologie, Koblenz 56068, Germany
| | - Thomas Rösch
- Clinic for Interdisciplinary Endoscopy, University Hospital Eppendorf, Hamburg 20251, Germany
| | - Stefan Groth
- Clinic for Interdisciplinary Endoscopy, University Hospital Eppendorf, Hamburg 20251, Germany
| | - Tanja Nowak
- CorporateHealth International, Hamburg 20149, Germany
| | - Peter Wohlmuth
- Biometry and Data Management, Asklepios Proresearch, Hamburg 20099, Germany
| | - Martin Keuchel
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| |
Collapse
|
6
|
Gachabayov M. Comments on: Colonoscopy at a tertiary health-care facility in Southwest Nigeria - spectrum of indications and colonic abnormalities. Ann Afr Med 2017; 16:35. [PMID: 28300051 PMCID: PMC5452703 DOI: 10.4103/aam.aam_38_16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Affiliation(s)
- Mahir Gachabayov
- Department of Abdominal Surgery, Vladimir City Clinical Hospital of Emergency Medicine, Vladimir, Russia
| |
Collapse
|
7
|
Sulz MC, Frei R, Semadeni GM, Sawatzki M, Borovicka J, Meyenberger C. The role of single-balloon colonoscopy for patients with previous incomplete standard colonoscopy: Is it worth doing it? Surg Endosc 2015; 30:1876-82. [PMID: 26183958 DOI: 10.1007/s00464-015-4405-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2015] [Accepted: 07/02/2015] [Indexed: 12/16/2022]
Abstract
BACKGROUND The rate of cecal intubation is a well-recognized quality measure of successful colonoscopy. Infrequently, the standard colonoscopy techniques fail to achieve complete examination. The role of single-balloon overtube-assisted colonoscopy (SBC) in these situations has only been sparsely studied. This prospective single-center study aimed to investigate the technical success (rate of cecal intubation) and the diagnostic gain of SBC. METHODS The study recruited consecutive patients with previous incomplete standard colonoscopy who were admitted for SBC at our tertiary center in Eastern Switzerland between February 2008 and October 2014. The primary outcome was defined as successful cecal intubation. Data on patient characteristics, indication, technical details of procedure, and outcome were collected prospectively. The Olympus enteroscope SIF-Q180 was used. RESULTS The study included 100 consecutive patients (median age 70 years; range 38-87 years; 54 % female) who were examined using a single-balloon overtube-assisted technique. The cecal intubation rate was 98 % (98/100). The median time of total procedure was 54 min (range 15-119 min); the median time to reach the cecal pole was 27.5 min (range 4-92 min). Passage of the sigmoid colon was not possible in two cases with a fixed, angulated sigmoid colon. The diagnostic gain was 21 % regarding adenomatous polyps in the right colon. The complication rate was 2 % (2/100, minor) without need for surgery. CONCLUSIONS This prospective patient cohort study shows that single-balloon colonoscopy is a safe and effective procedure to achieve a complete endoscopic examination in patients with a previous failed standard colonoscopy. A significant diagnostic and therapeutic gain in the right colon justifies additional procedure time.
Collapse
Affiliation(s)
- Michael Christian Sulz
- Division of Gastroenterology and Hepatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland.
| | - Remus Frei
- Division of Gastroenterology and Hepatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Gian-Marco Semadeni
- Division of Gastroenterology and Hepatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Mikael Sawatzki
- Division of Gastroenterology and Hepatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Jan Borovicka
- Division of Gastroenterology and Hepatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| | - Christa Meyenberger
- Division of Gastroenterology and Hepatology, Kantonsspital St. Gallen, Rorschacherstrasse 95, 9007, St. Gallen, Switzerland
| |
Collapse
|
8
|
Gan T, Yang JL, Wu JC, Wang YP, Yang L. When and why a colonoscopist should discontinue colonoscopy by himself? World J Gastroenterol 2015; 21:7834-7841. [PMID: 26167083 PMCID: PMC4491970 DOI: 10.3748/wjg.v21.i25.7834] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Revised: 04/03/2015] [Accepted: 05/21/2015] [Indexed: 02/06/2023] Open
Abstract
AIM: To investigate when and why a colonoscopist should discontinue incomplete colonoscopy by himself.
METHODS: In this cross-sectional study, 517 difficult colonoscope insertions (Grade C, Kudo’s difficulty classification) screened from 37800 colonoscopy insertions were collected from April 2004 to June 2014 by three 4th-level (Kudo’s classification) colonoscopists. The following common factors for the incomplete insertion were excluded: structural obstruction of the colon or rectum, insufficient colon cleansing, discontinuation due to patient’s discomfort or pain, severe colon disease with a perforation risk (e.g., severe ischemic colonopathy). All the excluded patients were re-scheduled if permission was obtained from the patients whose intubation had failed. If the repeat intubations were still a failure because of the difficult operative techniques, those patients were also included in this study. The patient’s age, sex, anesthesia and colonoscope type were recorded before colonoscopy. During the colonoscopic examination, the influencing factors of fixation, tortuosity, laxity and redundancy of the colon were assessed, and the insertion time (> 10 min or ≤ 10 min) were registered. The insertion time was analyzed by t-test, and other factors were analyzed by univariate and multivariate logistic regression.
RESULTS: Three hundred and twenty-two (62.3%) of the 517 insertions were complete in the colonoscope insertion into the ileocecum, but 195 (37.7%) failed in the insertion. Fixation, tortuosity, laxity or redundancy occurred during the colonoscopic examination. Multivariate logistic regression analysis revealed that fixation (OR = 0.06, 95%CI: 0.03-0.16, P < 0.001) and tortuosity (OR = 0.04, 95%CI: 0.02-0.08, P < 0.001) were significantly related to the insertion into the ileocecum in the left hemicolon; multivariate logistic regression analysis also revealed that fixation (OR = 0.16, 95%CI: 0.06-0.39, P < 0.001), tortuosity (OR 0.23, 95%CI: 0.13-0.43, P < 0.001), redundancy (OR = 0.12, 95%CI: 0.05-0.26, P < 0.001) and sex (OR = 0.35, 95%CI: 0.20-0.63, P < 0.001) were significantly related to the insertion into the ileocecum in the right hemicolon. Prolonged insertion time (> 10 min) was an unfavorable factor for the insertion into the ileocecum.
CONCLUSION: Colonoscopy should be discontinued if freedom of the colonoscope body’s insertion and rotation is completely lost, and the insertion time is prolonged over 30 min.
Collapse
|
9
|
Individual polyp detection rate in routine daily endoscopy practice depends on case-mix. Int J Colorectal Dis 2015; 30:927-32. [PMID: 25822995 DOI: 10.1007/s00384-015-2181-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/22/2015] [Indexed: 02/04/2023]
Abstract
INTRODUCTION The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. AIM To study the polyp detection rate (PDR) in different endoscopists in the course of years. PATIENTS AND METHODS All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. RESULTS In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p < 0.001), these two had the longest careers in endoscopy. The two younger endoscopists did significantly less often procedures in patients with anastomoses and because of surveillance (p < 0.001, respectively). One endoscopist detected significantly less colorectal cancers than the other three endoscopists (p < 0.001). CONCLUSION This study presents the PDR in normal routine daily endoscopy practice. It can be concluded that the PDR, implicating the ADR, in unselected patients can be lower in individual endoscopists than recommended in the literature. This highly depends on the case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.
Collapse
|
10
|
Daniels L, Ünlü Ç, de Wijkerslooth TR, Stockmann HB, Kuipers EJ, Boermeester MA, Dekker E. Yield of colonoscopy after recent CT-proven uncomplicated acute diverticulitis: a comparative cohort study. Surg Endosc 2014; 29:2605-13. [PMID: 25472747 DOI: 10.1007/s00464-014-3977-9] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2014] [Accepted: 11/04/2014] [Indexed: 12/13/2022]
Abstract
BACKGROUND Current guidelines recommend routine follow-up colonoscopy after acute diverticulitis to confirm the diagnosis and exclude malignancy. Its value, however, has recently been questioned because of contradictory study results. Our objective was to compare the colonoscopic detection rate of advanced colonic neoplasia (ACN), comprising colorectal cancer (CRC) and advanced adenoma (AA), in patients after a CT-proven primary episode of uncomplicated acute diverticulitis with average risk participants in a primary colonoscopy CRC screening program. METHODS A retrospective comparison was performed of prospectively collected data from cohorts derived from two multicenter randomized clinical trials executed in the Netherlands between 2009 and 2013. 401 uncomplicated diverticulitis patients and 1,426 CRC screening participants underwent colonic evaluation by colonoscopy. Main outcome was the diagnostic yield for ACN, calculated as number of diverticulitis patients and screening participants with ACN relative to their totals, with differences expressed as odds ratios (OR). The histopathology outcome of removed lesions during colonoscopy was used as definitive diagnosis. RESULTS AA detection was similar [5.5 vs. 8.7%; OR 0.62 (95% CI 0.38-1.01); P = 0.053]. CRC was detected in 1.2% (5/401) of diverticulitis patients versus 0.6% (9/1,426) of screening participants [OR 1.30 (95% CI 0.39-4.36); P = 0.673]. ACN was diagnosed in 6.7% (27/401) of diverticulitis patients versus 9.1% (130/1,426) of screening participants [OR 0.71 (95% CI 0.45-1.11); P = 0.134]. ORs were adjusted for age, family history of CRC, smoking, BMI, and cecal intubation rate. CONCLUSIONS ACN detection does not differ significantly between patients with recent uncomplicated diverticulitis and average risk screening participants. Routine follow-up colonoscopy after primary CT-proven uncomplicated left-sided acute diverticulitis can be omitted; these patients can participate in CRC screening programs. Follow-up colonoscopy may be beneficial when targeted at high-risk patients, but such an approach first needs prospective evaluation.
Collapse
Affiliation(s)
- Lidewine Daniels
- Department of Surgery - G4, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, The Netherlands,
| | | | | | | | | | | | | |
Collapse
|
11
|
Teshima CW, Zepeda-Gómez S, AlShankiti SH, Sandha GS. Magnetic imaging-assisted colonoscopy vs conventional colonoscopy: A randomized controlled trial. World J Gastroenterol 2014; 20:13178-13184. [PMID: 25278714 PMCID: PMC4177499 DOI: 10.3748/wjg.v20.i36.13178] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2014] [Revised: 05/29/2014] [Accepted: 06/26/2014] [Indexed: 02/06/2023] Open
Abstract
AIM: To compare magnetic imaging-assisted colonoscopy (MIC) with conventional colonoscopy (CC).
METHODS: Magnetic imaging technology provides a computer-generated image of the shape and position of the colonoscope onto a monitor to give visual guidance to the endoscopist. It is designed to improve colonoscopy performance and tolerability for patients by enabling visualization of loop formation and endoscope position. Recently, a new version of MIC technology was developed for which there are limited data.To evaluate this latest generation of MIC among experienced rather than inexperienced or trainee endoscopists, a prospective randomized trial was performed using only gastroenterologists with therapeutic endoscopy training. Consecutive patients undergoing elective outpatient colonoscopy were randomized to MIC or CC, with patients blinded to their group assignment. Endoscopic procedural metrics and quantities of conscious sedation medications were recorded during the procedures. The procedure was classified as “usual” or “difficult” by the endoscopist at the conclusion of each case based on the need for adjunctive maneuvers to facilitate endoscope advancement. After more than one hour post-procedure, patients completed a 10 cm visual analogue pain scale to reflect the degree of discomfort experienced during their colonoscopy. The primary outcome was patient comfort expressed by the visual analogue pain score. Secondary outcomes consisted of endoscopic procedural metrics as well as a sedation score derived from standardized dose increments of the conscious sedation medications.
RESULTS: Two hundred fifty-three patients were randomized and underwent MIC or CC between September 2011 and October 2012. The groups were similar in terms of the indications for colonoscopy and patient characteristics. There were no differences in cecal intubation rates (100% vs 99%), insertion distance-to-cecum (82 cm vs 83 cm), time-to-cecum (6.5 min vs 7.2 min), or polyp detection rate (47% vs 52%) between the MIC and CC groups. The primary outcome of mean pain score (1.0 vs 0.9 out of 10, P = 0.41) did not differ between MIC and CC groups, nor did the mean sedation score (8.2 vs 8.5, P = 0.34). Within the subgroup of cases considered more challenging or difficult, time-to-cecum was significantly faster with MIC compared to CC, 10.1 min vs 13.4 min respectively (P = 0.01). Sensitivity analyses confirmed a similar pattern of overall findings when each endoscopist was considered separately, demonstrating that the mean results for the entire group were not unduly influenced by outlier results from any one endoscopist.
CONCLUSION: Although the latest version of MIC resulted in faster times-to-cecum within a subgroup of more challenging cases, overall it was no better than CC in terms of patient comfort, sedation requirements and endoscopic procedural metrics, when performed in experienced hands.
Collapse
|
12
|
Nagrath N, Phull PS. Variation in caecal intubation rates between screening and symptomatic patients. United European Gastroenterol J 2014; 2:295-300. [PMID: 25083287 DOI: 10.1177/2050640614536898] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2013] [Accepted: 04/14/2014] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND The caecal intubation rate (CIR) is an important quality standard for endoscopists, as well as for national bowel cancer screening programmes; however, individuals undergoing colonoscopy for bowel screening and symptomatic patients represent different groups, and their characteristics may affect colonoscopy performance. OBJECTIVE To compare colonoscopists' performance, as assessed by the CIR, in symptomatic patients compared to individuals undergoing colonoscopy for bowel cancer screening. METHODS Retrospective audit of CIRs for all patients undergoing colonoscopy at our institution during the year 2008. We retrieved the data from an endoscopy reporting software database and from the local bowel cancer screening programme database. Demographic data was extracted, as well as details of known factors that may affect completion of colonoscopy, such as poor bowel preparation, presence of diverticular disease, polyps, tumour and strictures. The unadjusted CIRs for colonoscopists participating in the screening programme were compared between the bowel screening and the symptomatic patient groups. RESULTS Five screening colonoscopists performed 1056 colonoscopies, of which 488 were bowel screening procedures. The overall CIR was significantly lower in the symptomatic, compared to the screening, individuals (88.5% versus 93%, P < 0.02). No significant differences were observed between the two groups for risk factors that could impair the CIR. The CIR was <90% for two of the five colonoscopists in symptomatic patients, and just under 90% for one colonoscopist in screening individuals. Multivariate analysis revealed that non-screening colonoscopy was an independent predictor for an incomplete procedure (OR 1.8; 95% CI 1.2-2.8). CONCLUSIONS The CIR, a key quality performance indicator for colonoscopy, is lower in symptomatic patients compared to individuals undergoing colorectal cancer screening. These results suggested that CIR should be monitored independently in screening and non-screening colonoscopies.
Collapse
Affiliation(s)
- Nalin Nagrath
- University of Aberdeen Medical School, University of Aberdeen, Aberdeen, UK
| | - Perminder S Phull
- Department of Digestive Disorders, Aberdeen Royal Infirmary, Aberdeen, UK
| |
Collapse
|
13
|
Double-balloon endoscopy: an effective rescue procedure after incomplete conventional colonoscopy. Eur J Gastroenterol Hepatol 2014; 26:519-22. [PMID: 24584269 DOI: 10.1097/meg.0000000000000067] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
OBJECTIVE A significant percentage of colonoscopies remain incomplete because of a failure to intubate the caecum. By double-balloon endoscopy (DBE), originally developed for deep enteroscopy, an otherwise incomplete examination of the colon might be completed. We evaluated the success rate of caecal intubation, the reasons for its failure and the therapeutic consequences of using DBE after incomplete conventional colonoscopy. METHODS We report our single-centre experience of using DBE to complete an otherwise incomplete colonoscopy. A total of 114 consecutive patients, 45 male and 69 female, with a mean age of 64.8 years, who had undergone 116 procedures, were evaluated retrospectively by a review of their medical records. RESULTS The main causes for failed caecal intubation using a conventional colonoscope were loop formation in 70 patients (61.4%) and an adhesive angulated sigmoid in 33 (28.9%). Caecal intubation by DBE was successful in 101 patients (88.6%). The rate of failure was not associated with the cause of failure of the previous colonoscopy. In 55 patients (48.2%) a relevant new diagnosis was made in the previously inaccessible part of the colon: carcinoma (n=4; 3.5%), one or more adenomas (n=48; 42.1%) and caecal flat hyperplastic polyps (n=4; 3.5%). Endoscopic polypectomy was performed in 51 patients (44.7%); two complications occurred, both being mild postpolypectomy bleedings. In seven patients (6.1%) a subsequent surgical resection was performed. CONCLUSION Colonoscopy by DBE was useful in most patients in whom conventional colonoscopy was incomplete, irrespective of the cause of the failure. In nearly half the patients, a relevant new diagnosis was made with therapeutic consequences.
Collapse
|
14
|
Alarcón-Fernández O, Ramos L, Adrián-de-Ganzo Z, Gimeno-García AZ, Nicolás-Pérez D, Jiménez A, Quintero E. Effects of colon capsule endoscopy on medical decision making in patients with incomplete colonoscopies. Clin Gastroenterol Hepatol 2013; 11:534-40.e1. [PMID: 23078891 DOI: 10.1016/j.cgh.2012.10.016] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2012] [Revised: 09/05/2012] [Accepted: 10/01/2012] [Indexed: 02/06/2023]
Abstract
BACKGROUND & AIMS Colon capsule endoscopy (CCE) is an orally ingested colon imaging tool used to evaluate patients with colonic disease. We evaluated the efficacy of CCE in helping physicians make decisions about patients with incomplete conventional colonoscopies (ICCs). METHODS In a prospective study, we analyzed data from 34 patients with nonocclusive ICC who were eligible for CCE between May 2010 and April 2011; patients with colectomy, occlusive lesions, or inadequate bowel cleansing for the colonoscopy were excluded. Two experienced observers who were blinded to colonoscopy findings analyzed the CCE data. Four months later, medical records were reviewed to determine the effects of CCE on medical decision making. CCE was considered conclusive when the findings facilitated a medical decision. RESULTS Bowel cleanliness was good or excellent for 22 patients (64.7%). CCE exceeded the most proximal point reached by conventional colonoscopy in 29 patients (85.3%). CCE findings allowed formulation of a specific medical plan for 20 patients (58.8%); 12 (35.2%) had irrelevant or no lesions, so the study was concluded; 7 (20.5%) underwent polypectomy or surgery for advanced colorectal neoplasia; and 1 (3%) was treated for Crohn's disease. Inconclusive CCEs resulted from poor preparation of the bowel (n = 12) and excessively slow (n = 1) or rapid (n = 1) capsule transit. CONCLUSIONS CCE might be an alternative procedure to complete colon examination in patients with nonocclusive ICC.
Collapse
|
15
|
Kobayashi K, Mukae M, Ogawa T, Yokoyama K, Sada M, Koizumi W. Clinical usefulness of single-balloon endoscopy in patients with previously incomplete colonoscopy. World J Gastrointest Endosc 2013; 5:117-121. [PMID: 23515370 PMCID: PMC3600547 DOI: 10.4253/wjge.v5.i3.117] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2012] [Revised: 12/04/2012] [Accepted: 01/24/2013] [Indexed: 02/06/2023] Open
Abstract
AIM: To evaluate the clinical usefulness of single-balloon endoscopy (SBE) in patients in whom a colonoscope was technically difficult to insert previously.
METHODS: The study group comprised 15 patients (8 men and 7 women) who underwent SBE for colonoscopy (30 sessions). The number of SBE sessions was 1 in 7 patients, 2 in 5 patients, 3 in 1 patient, 4 in 1 patient, and 6 in 1 patient. In all patients, total colonoscopy was previously unsuccessful. The reasons for difficulty in scope passage were an elongated colon in 6 patients, severe intestinal adhesions after open surgery in 4, an elongated colon and severe intestinal adhesions in 2, a left inguinal hernia in 2, and multiple diverticulosis of the sigmoid colon in 1. Three endoscopists were responsible for SBE. The technique for inserting SBE in the colon was basically similar to that in the small intestine. The effectiveness of SBE was assessed on the basis of the success rate of total colonoscopy and the presence or absence of complications. We also evaluated the diagnostic and treatment outcomes of colonoscopic examinations with SBE.
RESULTS: Total colonoscopy was successfully accomplished in all sessions. The mean insertion time to the cecum was 22.9 ± 8.9 min (range 9 to 40). Abnormalities were found during 21 sessions of SBE. The most common abnormality was colorectal polyps (20 sessions), followed by radiation colitis (3 sessions) and diverticular disease of the colon (3 sessions). Colorectal polyps were resected endoscopically in 15 sessions. A total of 42 polyps were resected endoscopically, using snare polypectomy in 32 lesions, hot biopsy in 7 lesions, and endoscopic mucosal resection in 3 lesions. Fifty-six colorectal polyps were newly diagnosed on colonoscopic examination with SBE. Histopathologically, these lesions included 2 intramucosal cancers, 42 tubular adenomas, and 2 tubulovillous adenomas. The mean examination time was 48.2 ± 20.0 min (range 25 to 90). Colonoscopic examination or endoscopic treatment with SBE was not associated with any serious complications.
CONCLUSION: SBE is a useful and safe procedure in patients in whom a colonoscope is technically difficult to insert.
Collapse
|
16
|
Loffeld RJLF, Liberov B, Dekkers PEP. The yearly prevalence of findings in endoscopy of the lower part of the gastrointestinal tract. ISRN GASTROENTEROLOGY 2013; 2012:527634. [PMID: 23326676 PMCID: PMC3544271 DOI: 10.5402/2012/527634] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Accepted: 11/23/2012] [Indexed: 11/30/2022]
Abstract
Introduction. Endoscopy of the colon and rectum is increasingly used. Aim of the Study. All consecutive endoscopies of the colon and rectum were studied in order to assess the yearly prevalence of significant endoscopic diagnoses. Methods. All consecutive endoscopies of the colon and rectum were included. Endoscopies were done with endoscopes of Olympus. Significant endoscopic diagnoses were defined as colorectal cancer, polyps, diverticuli, large sessile polyps, and inflammatory bowel disease. Results. In 20 years a total of 24431 endoscopies were done. The yearly number of sigmoidoscopies was mean 96, range of 42–370. The number of colonoscopies was mean 1126, range of 643–1912. The number of colonoscopies significantly increased. The number of colonoscopies on request of an internist or gastroenterologist showed a slow but steady increase. Successful caecal intubation rose from 70% to 92% in 2011. Since 1996 there is a steep increase in the percentage of procedures with abnormalities. The number of cancer and polyps increased in twenty years. No great changes were seen in inflammatory bowel disease. Conclusion. Colonoscopy is a procedure with a high diagnostic yield. The number of patients with tumours rose in twenty years.
Collapse
Affiliation(s)
- R J L F Loffeld
- Department of Internal Medicine and Gastroenterology, Zaans Medisch Centrum, P.O. Box 210, 1500 EE Zaandam, The Netherlands
| | | | | |
Collapse
|
17
|
Dzeletovic I, Harrison ME, Pasha SF, Crowell MD, Decker GA, Gurudu SR, Leighton JA. Comparison of single- versus double-balloon assisted-colonoscopy for colon examination after previous incomplete standard colonoscopy. Dig Dis Sci 2012; 57:2680-6. [PMID: 22615017 DOI: 10.1007/s10620-012-2227-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2012] [Accepted: 04/30/2012] [Indexed: 02/06/2023]
Abstract
BACKGROUND Colonoscopy fails to achieve cecal intubation in 5-10 % of cases. Many of these cases can be completed using balloon-assisted colonoscopy, either with the single-balloon colonoscopy (SBC) or the double-balloon colonoscopy (DBC) techniques. AIM To compare the completion rates of SBC and DBC in patients with previous incomplete conventional colonoscopy. METHODS Between August 2009 and July 2011 either SBC or DBC was performed in 53 patients in whom previous conventional colonoscopy did not achieve cecal intubation. The medical records of these 53 patients were reviewed retrospectively for details regarding (1) indication for the initial colonoscopy, (2) patient characteristics, (3) data from the initial colonoscopy, and (4) details on both SBC and DBC. RESULTS SBC was successful in intubating the cecum in 100 % (26/26) of patients and DBC was successful in 93 % (25/27) of patients. The median (range) time to reach the cecum was 17 (9-43) min in the SBC group and 20 (7-58) min in the DBC group (P = 0.37). The presence of polyps was an entirely new finding in 35 % (9/26) of patients in the SBC group and 30 % (8/27) of patients in DBC group. Therapeutics were performed in 73 % (19/26) of patients in SBC group and 67 % (18/27) of patients in DBC group. CONCLUSION For patients with incomplete conventional colonoscopy, SBC and DBC offer high cecal intubation rates as well as detection of additional polyps and therapeutic capability. Either SBC or DBC can be considered after incomplete conventional colonoscopy.
Collapse
Affiliation(s)
- Ivana Dzeletovic
- Division of Gastroenterology and Hepatology, Mayo Clinic, 13400 East Shea Boulevard, Scottsdale, AZ 85259, USA.
| | | | | | | | | | | | | |
Collapse
|
18
|
Manta R, Mangiavillano B, Fedeli P, Viaggi P, Castellani D, Conigliaro R, Masci E, Bassotti G. Hood colonoscopy in trainees: a useful adjunct to improve the performance. Dig Dis Sci 2012; 57:2675-2679. [PMID: 22581341 DOI: 10.1007/s10620-012-2213-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2012] [Accepted: 04/25/2012] [Indexed: 12/22/2022]
Abstract
BACKGROUND The use of a transparent hood to improve colonoscopic performance has recently been proposed. AIMS The purpose of this study was to evaluate whether using the hood might improve the cecal intubation rate, cecal intubation time, number of attempts needed to intubate the ileo-cecal valve, and polyp detection rate in trainees. METHODS Patients undergoing colonoscopy (n = 378) were randomized in two groups, one studied with hood colonoscopy (n = 179) and the other (n = 199) with standard examination. RESULTS No differences were found between hood and standard colonoscopy with respect to cecal intubation rate (95 vs 92 %), whereas hood colonoscopy significantly shortened the cecal intubation time, the number of attempts needed to intubate the ileo-cecal valve, and the overall polyp detection rate (p < 0.01 for all these variables). CONCLUSIONS Hood colonoscopy might represent a useful adjunct to standard colonoscopy, especially improving the performance of endoscopic trainees.
Collapse
Affiliation(s)
- Raffaele Manta
- Gastroenterology and Gastrointestinal Endoscopy Unit, New Civil Sant' Agostino Estense Hospital, Baggiovara, Modena, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Riccioni ME, Urgesi R, Cianci R, Bizzotto A, Spada C, Costamagna G. Colon capsule endoscopy: Advantages, limitations and expectations. Which novelties? World J Gastrointest Endosc 2012; 4:99-107. [PMID: 22523610 PMCID: PMC3329617 DOI: 10.4253/wjge.v4.i4.99] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2011] [Revised: 02/20/2012] [Accepted: 03/30/2012] [Indexed: 02/05/2023] Open
Abstract
Since the first reports almost ten years ago, wireless capsule endoscopy has gained new fields of application. Colon capsule endoscopy represents a new diagnostic technology for colonic exploration. Clinical trials have shown that colon capsule endoscopy is feasible, accurate and safe in patients suffering from colonic diseases and might be a valid alternative to conventional colonoscopy in selected cases such as patients refusing conventional colonoscopy or with contraindications to colonoscopy or when colonoscopy is incomplete. Despite the enthusiasm surrounding this new technique, few clinical and randomized controlled trials are to be found in the current literature, leading to heterogeneous or controversial results. Upcoming studies are needed to prove the substantial utility of colon capsule endoscopy for colon cancer screening, especially in a low prevalence of disease population, and for other indications such as inflammatory bowel disease. Possible perspectives are critically analysed and reported in this paper.
Collapse
Affiliation(s)
- Maria Elena Riccioni
- Maria Elena Riccioni, Alessandra Bizzotto, Cristiano Spada, Guido Costamagna, Digestive Endoscopy Unit, Catholic University, 00168 Rome, Italy
| | | | | | | | | | | |
Collapse
|
20
|
Abstract
AIM The aetiology of colonoscopic perforation and factors related to poor outcome of surgical treatment were studied. METHOD A single-centre review was conducted of all patients who underwent surgical treatment of a colonoscopic perforation, identified from a prospective registry of 21,981 consecutive colonoscopies carried out between 1993 and 2009. RESULTS There were 29 (eight women) patients of mean age 73 years including 10 who had a nonelective colonoscopy. The perforation was not immediately recognized in 12 patients and in the remaining 17, seven were initially managed conservatively. The causes of perforation were barotrauma (11), mechanical force (14) and polypectomy-related (3). Barotrauma was more frequent in emergency colonoscopy and mechanical force in elective colonoscopy. The outcome of surgery was as follows: mortality 10%, complications 34.5%, reoperation 14%, secondary surgery 23% and permanent colostomy 3%. The only factor related to in-hospital mortality was an increased American Society of Anesthesiologists (ASA) score. CONCLUSION Colonoscopic perforation requiring surgery is a catastrophic event with high mortality, morbidity and reoperation rates.
Collapse
Affiliation(s)
- F J van der Sluis
- Departments of Surgery Gastroenterology, Zaans Medical Center, Zaandam, The Netherlands
| | | | | |
Collapse
|
21
|
Loffeld RJLF, Liberov B, Dekkers PEP. Yearly diagnostic yield of colonoscopy in patients age 80 years or older, with a special interest in colorectal cancer. Geriatr Gerontol Int 2011; 12:298-303. [PMID: 22050603 DOI: 10.1111/j.1447-0594.2011.00769.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
AIM A high diagnostic yield of colonoscopy has been reported in elderly patients, but there is no data on the yearly yield. Our aim was to detect the yearly yield of colonoscopy in elderly patients. METHODS All consecutive endoscopies in the years 1992-2009 were included. Important endoscopic diagnoses were defined as colorectal cancer (CRC), polyps, diverticuli and inflammation. RESULTS In total, 19 569 endoscopies were performed, of which 1706 (8.7%) were in patients age 80 years or older. The number of women was significantly higher (P < 0.001). The percentage of patients who were 80 years or older was higher than in the general population and remained stable during the study period, though there has been a proportional increase of elderly people in the general population. Inconclusive procedures were present in 106 (6.2%) elderly patients compared with 277 (1.6%) patients under 80 years of age (P < 0.001). There were no significant changes in the consecutive years. A procedure revealing no endoscopic diagnosis was observed less often in patients who were 80 years or older (P < 0.001). CRC was diagnosed in 221 (19.6%) older patients. This figure remained more or less constant each year. Polyps were seen in 448 (8.8%) patients 80 years of age or older. The percentage of patients with diverticuli and inflammation was constant. The number of patients 80 years or older with CRC and polyps rose at a lower rate than the number of older people in the general population. CONCLUSION The yield of colonoscopy in patients 80 years or older was high and constant over the years. The number of tumors rose less than expected compared to the increase of elderly in the general population.
Collapse
Affiliation(s)
- Ruud J L F Loffeld
- Department of Internal Medicine and Gastroenterology, Zaans Medisch Centrum, Zaandam, The Netherlands.
| | | | | |
Collapse
|
22
|
Khan S, Ahmed J, Lim M, Owais A, McNaught C, Mainprize K, Babu S, Renwick I, MacFie J, Mitchell C. Colonoscopy in the octogenarian population: Diagnostic and survival outcomes from a large series of patients. Surgeon 2011; 9:195-9. [DOI: 10.1016/j.surge.2010.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2010] [Revised: 08/03/2010] [Accepted: 09/08/2010] [Indexed: 12/31/2022]
|
23
|
Coppola F, Gaia S, Cosimato M, Recchia S. Enteroscope without overtube for cecal intubation after an incomplete colonoscopy. Dig Liver Dis 2011; 43:475-7. [PMID: 21334994 DOI: 10.1016/j.dld.2011.01.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2010] [Revised: 01/03/2011] [Accepted: 01/17/2011] [Indexed: 12/11/2022]
Abstract
BACKGROUND Cecal intubation is one of the targets of colon endoscopic evaluation, however even under experienced hands 5-10% of colonoscopies are incomplete. AIMS The aim of the study is to evaluate the usefulness of single balloon enteroscope (SBE) without employing overtube-balloon equipment in patients with incomplete colonoscopy. METHODS Between January 2009 and July 2010, patients with an incomplete standard colonscopy were prospectively enrolled to perform a colonoscopy with a single balloon enteroscope. Examinations were performed by the same expert operator during the same session. RESULTS Enteroscopy was performed on 79 patients, cecal intubation were obtained in 93.6% of the cases (74/79). It provided a new diagnosis in 43% of cases (34/79). Procedure was safe and well tolerated. Overall the additional use of single balloon enteroscope allowed to obtain the cecal intubation in up to 99.2% cases (898/905). CONCLUSIONS The use of the enteroscope without overtube-balloon equipment may be an effective method to increase the cecal intubation rate after failure of a standard colonoscopy.
Collapse
Affiliation(s)
- Franco Coppola
- Department of Gastroenterology, San Giovanni Bosco Hospital, Torino, Italy.
| | | | | | | |
Collapse
|
24
|
Badiani S, Hernandez ST, Karandikar S, Roy-Choudhury S. CT Colonography to exclude colorectal cancer in symptomatic patients. Eur Radiol 2011; 21:2029-38. [DOI: 10.1007/s00330-011-2151-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2010] [Revised: 03/19/2011] [Accepted: 03/23/2011] [Indexed: 12/22/2022]
|
25
|
Spada C, Hassan C, Sturniolo GC, Marmo R, Riccioni ME, de Franchis R, Van Gossum A, Costamagna G. Literature review and recommendations for clinical application of Colon Capsule Endoscopy. Dig Liver Dis 2011; 43:251-258. [PMID: 21067981 DOI: 10.1016/j.dld.2010.10.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2010] [Revised: 09/16/2010] [Accepted: 10/01/2010] [Indexed: 12/11/2022]
Abstract
Colon Capsule Endoscopy represents a new diagnostic technology for colonic exploration. Despite the great enthusiasm around this new technique, only few studies are available in the literature, and reported results are still controversial and non-homogeneous. Current preparation protocols have led to discordant results. In January 2010, the first Italian Meeting on Colon Capsule Endoscopy was held. Aim of this Meeting was to critically evaluate the available results obtained by Colon Capsule Endoscopy in clinical studies, in order to identify the proper test indications, to propose a shared preparation protocol and Colon Capsule Endoscopy procedure. Studies published in literature were extensively reviewed and analysed during the Meeting. The available evidence served to propose recommendations for preparation protocols, proper test indications and Colon Capsule Endoscopy procedure. Possible perspectives were also critically analysed and are reported in this paper.
Collapse
|
26
|
Cappell MS, Abboud R. The impact of advances in instrumentation and techniques of colonoscopy from 1988 to 2008 on inpatient colonoscopy performance at a high volume endoscopy unit in the United States: significantly shorter procedure time, higher completion rate, performance on sicker inpatients, and near disappearance of flexible sigmoidoscopy. Dig Dis Sci 2010; 55:3521-3529. [PMID: 20401535 DOI: 10.1007/s10620-010-1207-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/04/2010] [Accepted: 03/18/2010] [Indexed: 01/18/2023]
Abstract
BACKGROUND AND AIMS Colonoscopy instrumentation and technique have improved from 1988 to 2008. We analyze whether these improvements have resulted in improved colonoscopy performance. METHODS This was a retrospective study of 50 consecutive inpatients in 1988 vs. 1998 vs. 2008 undergoing intended colonoscopy at a teaching hospital. Patient APACHE score, cecal and terminal ileal intubation rates, procedure time, and colonoscopic diagnoses were compared for the three different years. RESULTS Changes in practice of inpatient colonoscopy in 2008 from 1988 include (1) remarkably sicker inpatients undergoing colonoscopy in 2008, as indicated by: significantly higher mean APACHE II score (11.0 ± 6.6 vs. 5.9 ± 4.1, P < 0.00001), significantly more frequent monitored bed status (58% vs. 10%, OR = 12.4; 95%-ORCI: 4.31-35.4, P < 0.00001), and significantly higher rates of several chronic diseases (e.g. CHF, 24% vs. 6%, P = 0.02); (2) significantly higher colonoscopy completion rate in 2008 (88% vs. 64%; OR = 4.13, 95%-ORCI: 1.51-11.2, P = 0.009); (3) significantly higher terminal ileum intubation rate in 2008 (44% vs. 14%, OR = 4.83, 95%-ORCI: 1.85-12.5, P = 0.002); and (4) significantly shorter mean procedure time in 2008 (26.3 ± 7.9 min vs. 48.0 ± 20.3 min, P < 0.00001). The ratio of intended colonoscopy/flexible sigmoidoscopy was significantly higher in 2008 vs. 1988 (OR = 7.50, 95%-ORCI: 2.56-21.8, P < 0.00001). Internal hemorrhoids were significantly more frequently diagnosed by colonoscopy in 2008 (44% vs. 12%, OR = 5.76, 95%-ORCI: 2.12-15.5, P = 0.001), attributed to increased rectal retroflexion. CONCLUSIONS Due to improved instrumentation and technique, colonoscopy has dramatically changed from 1988 to become a clinically more valuable test in 2008 as manifested by a higher completion rate, greater clinical applicability, and shorter procedure time. Colonoscopy is supplanting flexible sigmoidoscopy.
Collapse
Affiliation(s)
- Mitchell S Cappell
- Division of Gastroenterology, Department of Medicine, William Beaumont Hospital, MOB 233, 3535 W Thirteen Mile Road, Royal Oak, MI 48073, USA.
| | | |
Collapse
|
27
|
Abstract
Colonoscopy has become accepted as the most effective method of screening of the colon for neoplasia. Evidences prove that utilization of colonoscopy has increased dramatically in the past few years, largely because of increased rates of CRC screening. Effectiveness and safety of colonoscopy depend on the quality of examination, and growing body of evidence suggests that the quality of colonoscopy varies in clinical practice. Quality assurance of colonoscopy could be expected to contribute significantly to improved patient care. There is a clear need for evidence-based quality measures to ensure the quality of colonoscopy. In this review we present an overview of literature concerning criteria for best practice and important quality indicators for colonoscopy.
Collapse
Affiliation(s)
- László Herszényi
- Semmelweis Egyetem, Altalános Orvostudományi Kar II. Belgyógyászati Klinika, MTA Gasztroenterológiai és Molekuláris Medicina Kutatócsoport, Budapest, Szentkirályi u. 46. 1088.
| | | | | |
Collapse
|
28
|
Teshima CW, Aktas H, Haringsma J, Kuipers EJ, Mensink PBF. Single-balloon-assisted colonoscopy in patients with previously failed colonoscopy. Gastrointest Endosc 2010; 71:1319-23. [PMID: 20598261 DOI: 10.1016/j.gie.2010.02.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2010] [Accepted: 02/02/2010] [Indexed: 02/08/2023]
Abstract
BACKGROUND Despite advances in training and equipment, complete colonoscopy fails, even in experienced hands, in up to 10% of cases. Double-balloon endoscopy (DBE) has been successfully used to complete colonoscopy in these patients. Single-balloon endoscopy (SBE) has become established for small-bowel enteroscopy. However, it has yet to be studied for use in colonoscopy. OBJECTIVE To assess the efficacy, performance, and safety of single-balloon colonoscopy. DESIGN Prospective cohort study. SETTING Academic tertiary referral center. PATIENTS Patients with previously failed conventional colonoscopy. RESULTS 23 single-balloon colonoscopy procedures were performed in 22 patients: median age 53 (range 19-75) years; 14 females, 8 males. SBE colonoscopy succeeded in cecal intubation in 22 (96%) procedures, with a median total procedure time of 30 (range 20-60) minutes. SBE colonoscopy was normal in 9 cases but resulted in a positive diagnosis in 13 (57%) procedures, including polyps (n = 6), active Crohn's disease (n = 4), Crohn's-related stricture (n = 1), and diverticulosis (n = 2). Seven (30%) procedures were therapeutic including 1 case with balloon dilation and 6 cases with polypectomy. No complications were encountered. LIMITATIONS Limited sample size, no direct comparison with double-balloon endoscopy. CONCLUSIONS Single-balloon-assisted colonoscopy seems a safe and effective method for completing colonoscopy in patients with previously failed or difficult colonoscopy. The outcomes are similar compared with previous studies with DBE colonoscopy in this patient group.
Collapse
Affiliation(s)
- Christopher W Teshima
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, 3015 CE Rotterdam, The Netherlands
| | | | | | | | | |
Collapse
|