1
|
Cheng TF, Cheng KS. A randomized prospective study comparing single-balloon-assisted colonoscopy and cap-assisted colonoscopy in patients with previous incomplete conventional colonoscopy. J Gastroenterol Hepatol 2023; 38:225-232. [PMID: 36398729 DOI: 10.1111/jgh.16062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 11/01/2022] [Accepted: 11/14/2022] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Cecal intubation may be unsuccessful by conventional colonoscopy in some patients. Single-balloon-assisted colonoscopy (SBC) and cap-assisted colonoscopy (CAC) were studied to solve this problem. There was no head-to-head comparison between them. METHODS We conducted a randomized study from 2018 to 2021 to compare cecal intubation rate of SBC and CAC in patients with previous incomplete conventional colonoscopy. We recruited patients with incomplete conventional colonoscopy in two hospitals in Hong Kong. Patients were randomized into SBC group and CAC group in 1:1 ratio. In the case of failure in cecal intubation by allocated method, alternative modality would be performed as rescue. RESULTS Forty-four patients were recruited. Cecal intubation rate was superior in SBC group (22/22, 100%) than CAC group (16/22, 72.7%) (P = 0.02). No difference in cecal intubation time, polyp detection rate, and diagnostic gain in area not examined previously. SBC induced less discomfort (modified Gloucester comfort score 2.14 vs 2.63, P = 0.03) with use of comparable amount of midazolam and fentanyl as CAC. For patients failed cecal intubation by CAC, all (n = 6) were rescued successfully by SBC. Body weight, body mass index (BMI), and waist circumference were greater in rescue subgroup. More patients were obese (BMI ≥ 25 kg/m) in rescue subgroup (67% vs 19%). None in rescue subgroup had history of successful cecal intubation by conventional colonoscopy (0% vs 56%, P = 0.046). However, we failed to demonstrate significant association in multivariate analysis owing to small sample size. No adverse event was noted. CONCLUSION SBC is superior to CAC in cecal intubation in patients with previous incomplete conventional colonoscopy.
Collapse
Affiliation(s)
- Tsz Fai Cheng
- Department of Medicine and Geriatrics, Tuen Mun Hospital, Tuen Mun, Hong Kong
| | - Ka Shing Cheng
- Department of Medicine and Geriatrics, Tuen Mun Hospital, Tuen Mun, Hong Kong
| |
Collapse
|
2
|
Al-Toma A, Oude Hergelink DM, Tenthof van Noorden J, Koornstra JJ. Prospective evaluation of the motorized spiral enteroscope for previous incomplete colonoscopy. Endosc Int Open 2022; 10:E1112-E1117. [PMID: 36238532 PMCID: PMC9552671 DOI: 10.1055/a-1869-2541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 05/30/2022] [Indexed: 11/23/2022] Open
Abstract
Background and study aims A significant percentage of colonoscopies remain incomplete because of failure to intubate the cecum. The motorized spiral enteroscope (MSE) technique, originally developed for deep small bowel enteroscopy, may be an effective alternative technique in cases of incomplete examination of abnormally long colons (dolichocolon). We prospectively evaluated the success rate of cecal intubation, safety and the therapeutic consequences of using MSE after incomplete conventional colonoscopy. Patients and methods A total of 36 consecutive patients with an indication for diagnostic and/or therapeutic colonoscopy were prospectively enrolled in this multicenter trial. All patients had undergone at least one incomplete colonoscopy attributed to abnormally long colons. Patients with incomplete colonoscopy due to stenosis were excluded. Results Twenty-two men and 14 women (median age 66 years, range 35-82) were enrolled. Median procedure time was 30 minutes (range 16-50). Cecal intubation rate was 100 % and median cecal intubation time was 10 minutes (range 4-30). Abnormalities, mostly neoplastic lesions, were detected in 23 of 36 patients, corresponding to a diagnostic yield of 64 %. All these findings were in the right side of the colon and had not been described by the antecedent incomplete coloscopy. No adverse events occurred. Conclusions In case of a difficult and long colon, MSE is safe and effective for diagnostic and therapeutic colonoscopy. It may provide an attractive solution to accomplish completeness of previous incomplete colonoscopies in these patients.
Collapse
Affiliation(s)
- Abdulbaqi Al-Toma
- Department of Gastroenterology and hepatology, St. Antonius hospital, Nieuwegein, the Netherlands
| | - Dorien M. Oude Hergelink
- Department of Gastroenterology & Hepatology, University Medical Centre Groningen, University of Groningen, The Netherlands
| | | | - Jan Jacob Koornstra
- Department of Gastroenterology & Hepatology, University Medical Centre Groningen, University of Groningen, The Netherlands
| |
Collapse
|
3
|
Alexander R R, Anastasios K, Diana E Y, Christopher F, Artur N, Kenneth T, Ervin T, John N P, Gabriele WJ. Balloon-Assisted Colonoscopy after Incomplete Conventional Colonoscopy-Experience from Two European Centres with A Comprehensive Review of the Literature. J Clin Med 2020; 9:2981. [PMID: 32942749 PMCID: PMC7564861 DOI: 10.3390/jcm9092981] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Revised: 09/03/2020] [Accepted: 09/11/2020] [Indexed: 12/22/2022] Open
Abstract
Conventional colonoscopy (CC) allows access for colonic investigation and intervention; in the small group in whom CC is unsuccessful alternative imaging is often sufficient. There remains a subset, however, requiring full colonic visualisation or intervention. Balloon-assisted colonoscopy (BAC) gives a further option when access is difficult. Aims: This study aims to present the experience with BAC of two European tertiary referral centres. Methods: Procedures were carried out under local protocol over 15-years (2006-2020). Markers of procedural quality such as caecal intubation, complications and comfort were retrospectively compiled and analysed. Published evidence was summarised for comparison. Results: 122 procedures were undertaken, with polyps the most frequent indication and 90.2% having at least one previously incomplete CC. Features associated with difficult colonoscopy were common, including intraabdominal surgery (32.0%). 92.6% reached the caecum; completion was higher (96.3%) in those failing CC due to discomfort and lower in those failing due to anatomical difficulties (90.7%) or previous surgery (84.6%). Mean time to the caecum was 20.9 minutes and mean midazolam and fentanyl doses were 2.6 mg and 49.9 µg with low discomfort scores. Conclusion(s): Balloon-assisted colonoscopy is successful in >90% of patients, is well-tolerated, and is safe.
Collapse
Affiliation(s)
| | | | - Yung Diana E
- Centre for Liver & Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK; (Y.D.E.); (T.K.); (P.J.N.)
| | - Fraser Christopher
- Endoscopy Unit, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK;
| | - Nemeth Artur
- Department of Gastroenterology, Skane University Hospital, Lund University, 205 02 Malmö, Sweden; (N.A.); (T.E.); (W.J.G.)
| | - Trimble Kenneth
- Centre for Liver & Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK; (Y.D.E.); (T.K.); (P.J.N.)
| | - Toth Ervin
- Department of Gastroenterology, Skane University Hospital, Lund University, 205 02 Malmö, Sweden; (N.A.); (T.E.); (W.J.G.)
| | - Plevris John N
- Centre for Liver & Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK; (Y.D.E.); (T.K.); (P.J.N.)
| | - Wurm Johansson Gabriele
- Department of Gastroenterology, Skane University Hospital, Lund University, 205 02 Malmö, Sweden; (N.A.); (T.E.); (W.J.G.)
| |
Collapse
|
4
|
Parsa N, Vemulapalli KC, Rex DK. Performance of radiographic imaging after incomplete colonoscopy for nonmalignant causes in clinical practice. Gastrointest Endosc 2020; 91:1371-1377. [PMID: 32032619 DOI: 10.1016/j.gie.2020.01.043] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 01/22/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS CT colonography (CTC) or barium enema are commonly ordered to complete colorectal imaging after an incomplete colonoscopy. We evaluated the sensitivity of radiographic studies performed for this purpose in clinical practice outside clinical trials. METHODS Adult patients referred to an expert endoscopist for incomplete colonoscopy because of a redundant colon or a difficult sigmoid and who underwent previous radiographic imaging between July 2001 and July 2019 were identified. None of the patients had a malignant obstruction as the cause of incomplete colonoscopy. Data on polyp size, location, and pathology were obtained from colonoscopy and radiology reports. Polyps identified on imaging and colonoscopy were matched based on polyp size and location. RESULTS Among 769 patients referred for incomplete colonoscopy, we identified 65 with a radiographic examination performed within 36 months of colonoscopy at our center. Per-patient sensitivity for CTC was suboptimal (70%) and was very low for barium enema (26.7%). Per-polyp sensitivity for both CTC and barium enema was poor (23.8% and 7.6%). Quality of the examination did not seem to affect procedure sensitivity. CONCLUSIONS Radiographic imaging after incomplete colonoscopy for reasons other than malignant obstruction had poor sensitivity for polyps. Patients with incomplete colonoscopies should be considered for repeat colonoscopy by an expert.
Collapse
Affiliation(s)
- Nasim Parsa
- Division of Gastroenterology and Hepatology, University of Missouri, Columbia, Missouri, USA
| | - Krishna C Vemulapalli
- Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| | - Douglas K Rex
- Division of Gastroenterology/Hepatology, Indiana University School of Medicine, Indianapolis, Indiana, USA
| |
Collapse
|
5
|
Baltes P, Bota M, Albert J, Philipper M, Hörster HG, Hagenmüller F, Steinbrück I, Jakobs R, Bechtler M, Hartmann D, Neuhaus H, Charton JP, Mayershofer R, Hohn H, Rösch T, Groth S, Nowak T, Wohlmuth P, Keuchel M. PillCamColon2 after incomplete colonoscopy - A prospective multicenter study. World J Gastroenterol 2018; 24:3556-3566. [PMID: 30131662 PMCID: PMC6102503 DOI: 10.3748/wjg.v24.i31.3556] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 07/18/2018] [Accepted: 07/21/2018] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield.
METHODS This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours.
RESULTS Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn’s disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda.
CONCLUSION Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
Collapse
Affiliation(s)
- Peter Baltes
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| | - Marc Bota
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| | - Jörg Albert
- Department of Internal Medicine I, Klinikum der JW. Goethe Universität, Frankfurt 60590, Germany
| | | | | | | | - Ingo Steinbrück
- 1st Medical Department, Asklepios Klinikum Altona, Hamburg 22763, Germany
| | - Ralf Jakobs
- Medical Clinic C, Klinikum der Stadt Ludwigshafen, Ludwigshafen 67063, Germany
| | - Matthias Bechtler
- Medical Clinic C, Klinikum der Stadt Ludwigshafen, Ludwigshafen 67063, Germany
| | - Dirk Hartmann
- Clinic for Internal Medicine, Sana Klinikum Lichtenberg, Berlin 10365, Germany
| | - Horst Neuhaus
- Clinic for Internal Medicine, Evangelisches Krankenhaus, Düsseldorf 40217, Germany
| | - Jean-Pierre Charton
- Clinic for Internal Medicine, Evangelisches Krankenhaus, Düsseldorf 40217, Germany
| | | | - Horst Hohn
- Schwerpunktpraxis Gastroenterologie, Koblenz 56068, Germany
| | - Thomas Rösch
- Clinic for Interdisciplinary Endoscopy, University Hospital Eppendorf, Hamburg 20251, Germany
| | - Stefan Groth
- Clinic for Interdisciplinary Endoscopy, University Hospital Eppendorf, Hamburg 20251, Germany
| | - Tanja Nowak
- CorporateHealth International, Hamburg 20149, Germany
| | - Peter Wohlmuth
- Biometry and Data Management, Asklepios Proresearch, Hamburg 20099, Germany
| | - Martin Keuchel
- Clinic for Internal Medicine, Bethesda Krankenhaus Bergedorf, Hamburg 21029, Germany
| |
Collapse
|
6
|
Trindade AJ, Lichtenstein DR, Aslanian HR, Bhutani MS, Goodman A, Melson J, Navaneethan U, Pannala R, Parsi MA, Sethi A, Sullivan S, Thosani N, Trikudanathan G, Watson RR, Maple JT. Devices and methods to improve colonoscopy completion (with videos). Gastrointest Endosc 2018; 87:625-634. [PMID: 29454445 DOI: 10.1016/j.gie.2017.12.011] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Accepted: 12/22/2017] [Indexed: 02/08/2023]
|
7
|
Hermans C, Zee DVD, Gilissen L. Double-Balloon Endoscopy after Incomplete Colonoscopy and Its Comparison with Computed Tomography Colonography. Clin Endosc 2018; 51:66-71. [PMID: 29316779 PMCID: PMC5806920 DOI: 10.5946/ce.2017.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2016] [Revised: 10/08/2017] [Accepted: 10/25/2017] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND/AIMS Because of the national screening program for colorectal carcinoma in The Netherlands, the number of colonoscopies has increased. In case of incomplete colonoscopy, computed tomography colonography (CTC) and double-balloon colonoscopy (DBc) are alternative options. This study evaluated cecal intubation rate and pathology detection rate in the previously unexplored part of the colon, complication rate of DBc, and CTC results after incomplete colonoscopy. METHODS Retrospective observational study in a tertiary referral hospital regarding DBc and CTC reports from cases with incomplete colonoscopy. RESULTS Sixty-three DBcs were performed after incomplete colonoscopy. Cecal intubation rate was 95%. Detection rate was 58% (5% carcinoma and 3% high-grade dysplastic adenoma). CTC preceded 54% of DBcs and 62% of CTC findings were confirmed. In 16%, a biopsy was taken, and in 60%, an intervention (mostly polypectomy) was performed. One major complication (1.5%) occurred, i.e., arterial bleeding due to polypectomy necessitating right hemicolectomy. CTC (n=213) showed a possible lesion in 35%, and could be confirmed by follow-up endoscopy or surgery in 65%. CONCLUSIONS DBc is effective and safe for completion of colon inspection in incomplete colonoscopy. In patients with a high likelihood of pathology, DBc is preferred over CTC.
Collapse
Affiliation(s)
- Carlijn Hermans
- Department of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| | - Dennis van der Zee
- Department of Radiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| | - Lennard Gilissen
- Department of Gastroenterology and Hepatology, Catharina Hospital Eindhoven, Eindhoven, Netherlands
| |
Collapse
|
8
|
Sunada K, Shinozaki S, Yano T, Hayashi Y, Sakamoto H, Lefor AK, Yamamoto H. Double-Balloon Colonoscopy Has a Higher Cecal Intubation Rate Than Conventional Colonoscopy Using a Colon Simulator. Dig Dis Sci 2017; 62:979-983. [PMID: 28194595 DOI: 10.1007/s10620-017-4477-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2016] [Accepted: 01/25/2017] [Indexed: 12/09/2022]
Abstract
BACKGROUND/AIM Cecal intubation using conventional colonoscopy (CC) requires substantial training. We hypothesized that double-balloon colonoscopy (DBC) facilitates cecal intubation by endoscopy naïve operators. The aim of this study is to evaluate the cecal intubation rate and learning curve of DBC compared with CC. METHODS Eighteen endoscopy naïve medical students were allocated to two groups and attempted cecal intubation within 20 min using a colon simulator. In group A, CC was performed ten times and then DBC ten times. In group B, the reverse was carried out. We evaluated the cecal intubation rate and learning curve. RESULTS The overall success rate for cecal intubation using DBC was significantly superior to CC [132/180 (73%) vs. 12/180 (7%), p < 0.001]. To evaluate the success rate overtime, we divided the ten repetitions of the procedure into three time periods: first (1-3), second (4-6), and third (7-10). The success rate using CC is <20%, even during the third time period, in both groups, and one perforation occurred. The success rate using DBC is over 30% in the first period and increased to nearly 80% in the third period in both groups. Finally, we evaluated the time needed for cecal intubation using DBC. The mean cecal intubation time in the first period is 14 min and decreased to 11 min in the third period. CONCLUSIONS DBC has a higher cecal intubation rate than CC performed by endoscopy naïve medical students using a colon simulator in this randomized-controlled, cross-over study.
Collapse
Affiliation(s)
- Keijiro Sunada
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan
| | - Satoshi Shinozaki
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.,Shinozaki Medical Clinic, Tochigi, Japan
| | - Tomonori Yano
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan
| | - Yoshikazu Hayashi
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan
| | - Hirotsugu Sakamoto
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan
| | | | - Hironori Yamamoto
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi, 329-0498, Japan.
| |
Collapse
|
9
|
Yung DE, Koulaouzidis A, Fraser C, Trimble KC, Plevris JN. Double-balloon colonoscopy for failed conventional colonoscopy: the Edinburgh experience and systematic review of existing data. Gastrointest Endosc 2016; 84:878-881. [PMID: 27742052 DOI: 10.1016/j.gie.2016.06.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Accepted: 06/12/2016] [Indexed: 12/11/2022]
Affiliation(s)
- Diana E Yung
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| | | | - Chris Fraser
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| | - Ken C Trimble
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| | - John N Plevris
- Centre for Liver and Digestive Disorders, The Royal Infirmary of Edinburgh, Edinburgh, UK
| |
Collapse
|
10
|
Abstract
A thorough and complete colonoscopy is critically important in preventing colorectal cancer. Factors associated with difficult and incomplete colonoscopy include a poor bowel preparation, severe diverticulosis, redundant colon, looping, adhesions, young and female patients, patient discomfort, and the expertise of the endoscopist. For difficult colonoscopy, focusing on bowel preparation techniques, appropriate sedation and adjunct techniques such as water immersion, abdominal pressure techniques, and patient positioning can overcome many of these challenges. Occasionally, these fail and other alternatives to incomplete colonoscopy have to be considered. If patients have low risk of polyps, then noninvasive imaging options such as computed tomography (CT) or magnetic resonance (MR) colonography can be considered. Novel applications such as Colon Capsule™ and Check-Cap are also emerging. In patients in whom a clinically significant lesion is noted on a noninvasive imaging test or if they are at a higher risk of having polyps, balloon-assisted colonoscopy can be performed with either a single- or double-balloon enteroscope or colonoscope. The application of these techniques enables complete colonoscopic examination in the vast majority of patients.
Collapse
|
11
|
Hotta K, Katsuki S, Ohata K, Abe T, Endo M, Shimatani M, Nagaya T, Kusaka T, Matsuda T, Uraoka T, Yamaguchi Y, Murakami Y, Saito Y. Efficacy and safety of endoscopic interventions using the short double-balloon endoscope in patients after incomplete colonoscopy. Dig Endosc 2015; 27:95-8. [PMID: 24889819 DOI: 10.1111/den.12318] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/26/2014] [Accepted: 05/26/2014] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIM We have previously reported excellent cecal intubation rates using a short double-balloon endoscope in patients with a history of incomplete colonoscopy. However, data on the endoscopic treatment of colorectal tumors using a double-balloon endoscope are limited. The aim of the present study was to evaluate the efficacy and safety of endoscopic intervention of colorectal tumors using a short double-balloon endoscope. METHODS We analyzed data from a multicenter, prospective study on 110 patients (62 men, median age 66.5 years) who underwent total colonoscopy after incomplete colonoscopy to assess the characteristics of colorectal tumors, endoscopic interventions, and complications. RESULTS In all, 113 colorectal tumors were detected in 55 patients; 109 of the tumors were adenomas (24 advanced adenomas) and two each were intramucosal and advanced cancers. Locations of the lesions were eight in the cecum, 30 in the ascending colon, 18 in the transverse colon, 12 in the descending colon, 34 in the sigmoid colon, five in the rectosigmoid and six in the rectum. Average tumor diameter was 6.8 ± 6.3 mm. Fifty-nine polypectomies, 22 endoscopic mucosal resections, four hot biopsies, and six cold biopsies were done. All endoscopic interventions were successfully completed and no complications were noted. Two advanced cancers were located in the ascending colon and only a double-balloon endoscope could reach them to take a biopsy sample. CONCLUSION Double-balloon endoscopy is effective and safe for endoscopic intervention of colorectal tumors, irrespective of the location, in patients after incomplete colonoscopy.
Collapse
Affiliation(s)
- Kinichi Hotta
- Department of Gastroenterology, Saku Central Hospital, Saku, Japan; Division of Endoscopy, Shizuoka Cancer Center, Sunto, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Factors Influencing Cecal Intubation Time during Retrograde Approach Single-Balloon Enteroscopy. Gastroenterol Res Pract 2014; 2014:212307. [PMID: 25505904 PMCID: PMC4258379 DOI: 10.1155/2014/212307] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 10/25/2014] [Accepted: 11/05/2014] [Indexed: 01/10/2023] Open
Abstract
Background and Aim. The predisposing factors for prolonged cecal intubation time (CIT) during colonoscopy have been well identified. However, the factors influencing CIT during retrograde SBE have not been addressed. The aim of this study was to determine the factors influencing CIT during retrograde SBE. Methods. We investigated patients who underwent retrograde SBE at a medical center from January 2011 to March 2014. The medical charts and SBE reports were reviewed. The patients' characteristics and procedure-associated data were recorded. These data were analyzed with univariate analysis as well as multivariate logistic regression analysis to identify the possible predisposing factors. Results. We enrolled 66 patients into this study. The median CIT was 17.4 minutes. With univariate analysis, there was no statistical difference in age, sex, BMI, or history of abdominal surgery, except for bowel preparation (P = 0.021). Multivariate logistic regression analysis showed that inadequate bowel preparation (odds ratio 30.2, 95% confidence interval 4.63-196.54; P < 0.001) was the independent predisposing factors for prolonged CIT during retrograde SBE. Conclusions. For experienced endoscopist, inadequate bowel preparation was the independent predisposing factor for prolonged CIT during retrograde SBE.
Collapse
|
13
|
Tutticci N, Bourke MJ. Advances in colonoscopy. CURRENT TREATMENT OPTIONS IN GASTROENTEROLOGY 2014; 12:119-139. [PMID: 24615389 DOI: 10.1007/s11938-014-0009-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Colonoscopy with polypectomy has been established as the major prevention and detection strategy for colorectal cancer for over a decade. Over this period advances in colonoscopic imaging, polyp detection, prediction of histopathology and polypectomy techniques have all been seen; however, the true magnitude of the limitations of colonoscopy has only recently been widely recognized. The rate and location of missed or interval cancers after complete colonoscopy appears to be influenced by the operator-dependency of colonoscopy and failure of conventional practices to detect and treat adenomatous, and possibly more importantly, non-adenomatous colorectal cancer precursors. Consequently, studies that expand our understanding of these factors and advances that aim to improve colonoscopy, polypectomy, and cancer protection are of critical importance.
Collapse
Affiliation(s)
- Nicholas Tutticci
- Department of Gastroenterology and Hepatology, Westmead Hospital, 106A/151 Hawkesbury Road, Westmead, NSW, 2145, Australia,
| | | |
Collapse
|
14
|
Gawron AJ, Veerappan A, Keswani RN. High success rate of repeat colonoscopy with standard endoscopes in patients referred for prior incomplete colonoscopy. BMC Gastroenterol 2014; 14:56. [PMID: 24679009 PMCID: PMC3986859 DOI: 10.1186/1471-230x-14-56] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2013] [Accepted: 03/21/2014] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND In patients with incomplete colonoscopy, cecal intubation is sometimes unsuccessful due to a redundant or tortuous colon. Repeat colonoscopy may be successful with the use of alternate endoscopes or careful attention to technique but limited outcomes data is available. The aim of this study was to describe the technique, success rate and outcomes of consecutive patients referred for previous incomplete colonoscopy. METHODS We conducted a retrospective chart review of incomplete colonoscopy procedures in patients age 18-90 at an academic teaching hospital referred to an endoscopist specializing in difficult colonoscopy. RESULTS Cecal intubation was successful in 96 of 100 repeat colonoscopies and 83 procedures were completed with a standard endoscope (adult, pediatric, or gastroscope). The adenoma detection rate was 28% for successful repeat colonoscopies; a majority of these patients had no adenomas identified on incomplete exam. In 69.4% of cases, an endoscope was used to successfully complete colonoscopy that was not used in the incomplete colonoscopy. The median insertion time was significantly less for the complete colonoscopy (10.6 min) compared to the incomplete colonoscopy (18.8 min, P = 0.004). CONCLUSIONS Repeat colonoscopy has a high success rate and identified a significant number of new adenomas. Use of all available endoscopes should be considered prior to procedure termination in patients with a tortuous colon. Repeat colonoscopy can often be accomplished using a standard endoscope and is not attributed to increased endoscope insertion time.
Collapse
Affiliation(s)
| | | | - Rajesh N Keswani
- Division of Gastroenterology and Hepatology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA.
| |
Collapse
|
15
|
Triantafyllou K, Viazis N, Tsibouris P, Zacharakis G, Kalantzis C, Karamanolis DG, Ladas SD. Colon capsule endoscopy is feasible to perform after incomplete colonoscopy and guides further workup in clinical practice. Gastrointest Endosc 2014; 79:307-316. [PMID: 24060522 DOI: 10.1016/j.gie.2013.07.061] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2013] [Accepted: 07/31/2013] [Indexed: 02/08/2023]
Abstract
BACKGROUND Colon capsule endoscopy (CCE) could be an option to examine the colon after incomplete colonoscopy. OBJECTIVE To investigate the extent that CCE complements incomplete colonoscopy and guides further workup. DESIGN Prospective, follow-up study. SETTING Three tertiary-care centers. PATIENTS Consecutive outpatients after colonoscopy failure; 1-year study period. INTERVENTION Patients underwent CCE either immediately after colonoscopy or were rescheduled. Further investigations were guided by the results of CCE. Patients were followed as long as 2 years. RESULTS We studied 75 outpatients; 39 had a screening colonoscopy. One third of the patients underwent CCE immediately after colonoscopy. Overall, CCE reached or went beyond the colon segment at which colonoscopy stopped in 68 patients (91%). CCE technically complemented difficult colonoscopy independently of whether same-day CCE was performed (24 [96%]) or was not performed (44 [88%]). CCE detected additional significant findings in 36% of the same-day CCE cases and in 48% of the rescheduled ones. Two patients in the same-day group and 13 in the rescheduled CCE group underwent further colon examination that revealed additional significant findings in 3 of them. Ten percent of the patients reported mild adverse events (AE). If needed, 63 participants (84%) were willing to repeat CCE. Follow-up has not identified symptomatic missed colon cancers. LIMITATIONS Selected patient population, first-generation colon capsule, old preparation scheme. CONCLUSION CCE performed immediately or at a scheduled date after colonoscopy failure is feasible and safe. CCE after incomplete colonoscopy appears to yield significant findings, guide further workup, and has high patient acceptance.
Collapse
Affiliation(s)
- Konstantinos Triantafyllou
- Hepatogastroenterology Unit, Second Department of Internal Medicine and Research Institute, Attikon University General Hospital, Medical School, Athens University, Athens, Greece
| | - Nikos Viazis
- Second Department of Gastroenterology, Evangelismos General Hospital, Athens, Greece
| | | | - Georgios Zacharakis
- Second Department of Gastroenterology, Evangelismos General Hospital, Athens, Greece
| | | | | | - Spiros D Ladas
- Academic Department of Gastroenterology, Laiko General Hospital, Medical School, Athens University, Athens, Greece
| |
Collapse
|
16
|
Renewed attention for overtube-assisted colonoscopy to prevent incomplete endoscopic examination of the colon. Dis Colon Rectum 2013; 56:1013-8. [PMID: 23838871 DOI: 10.1097/dcr.0b013e3182962636] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
BACKGROUND Colonoscopy is the standard examination to detect mucosal pathology in the colon. However, failure to complete colonoscopy may reach more than 10% in population-based endoscopy practices. The reasons for incomplete conventional colonoscopy are diverse and result in missed diagnosis of colonic polyps and carcinoma. OBJECTIVE Recent endoscopic developments have shown that the use of specialized overtubes may help to reach the cecum in the case of a difficult colonoscopy, even with less discomfort. Several types of overtubes are currently available, whereas other types are being developed and clinically evaluated. The current review highlights the development of overtubes for colonoscopy and the available clinical data on overtube-assisted colonoscopy in the case of incomplete conventional colonoscopy. DATA SOURCES Data were derived from a PubMed search through November 2012. STUDY SELECTION Available clinical literature data on recent developments in overtube-assisted colonoscopy were studied. INTERVENTION A descriptive comparison was made of currently available endoscopy systems used for overtube-assisted colonoscopy. MAIN OUTCOME MEASURES The primary outcomes measured were the feasibility and safety of different endoscopy systems to perform overtube-assisted colonoscopy. RESULTS Several overtube-assisted colonoscopy systems have recently been developed to complete colonoscopy in the case of difficult conventional colonoscopy. Literature data show excellent feasibility to reach the cecum with very low complication rates and good patient tolerance for the different overtube systems. LIMITATIONS The majority of available studies are uncontrolled case series describing 7 to 110 patients undergoing overtube-assisted colonoscopy with only 1 direct comparison between 2 overtube systems. CONCLUSIONS Overtube-assisted colonoscopy has been shown to be useful in performing colonoscopy by increasing the cecal intubation rate and patient tolerance and by decreasing the need for sedation. There is no standardized superior overtube system at this moment.
Collapse
|
17
|
Atia MA, Ramirez FC, Leighton JA. The dilemma of incomplete colonoscopy: what is the next best test? Clin Gastroenterol Hepatol 2013; 11:541-2. [PMID: 23246647 DOI: 10.1016/j.cgh.2012.11.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Accepted: 11/30/2012] [Indexed: 02/07/2023]
|
18
|
Single- versus double-balloon-assisted colonoscopy after previous incomplete standard colonoscopy. Dig Dis Sci 2012; 57:2490-2. [PMID: 22833382 DOI: 10.1007/s10620-012-2318-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/24/2012] [Accepted: 07/06/2012] [Indexed: 12/22/2022]
|