Table 1 Average monthly and overall maximum sound level, L10, L50, L90 (representing sound levels exceeding 10%, 50%, and 90% of the time, respectively), equivalent continuous noise level and sound exposure level
| Lmax | L90 | L10 | L50 | Leq | SEL | |
| December 2024 | 82.3 ± 4.9 | 56.5 ± 3.1 | 67.6 ± 3.2 | 61.5 ± 3.4 | 64.8 ± 2.9 | 97.4 ± 2.9 |
| January 2025 | 82.1 ± 4.5 | 55.5 ± 2.6 | 67.0 ± 2.8 | 60.6 ± 3.0 | 64.2 ± 2.6 | 96.7 ± 2.6 |
| February 2025 | 82.8 ± 4.0 | 56.4 ± 2.9 | 67.9 ± 2.8 | 61.5 ± 3.2 | 65.1 ± 2.7 | 97.7 ± 2.7 |
| March 2025 | 82.7 ± 4.2 | 57.1 ± 2.3 | 67.6 ± 2.8 | 61.6 ± 2.9 | 64.9 ± 2.7 | 97.5 ± 2.7 |
| December 2024 - March 2025 | 82.5 ± 4.4 | 56.4 ± 2.8 | 67.5 ± 2.9 | 61.3 ± 3.2 | 64.8 ± 2.8 | 97.7 ± 2.8 |
Table 2 Sound metrics during activity hours
| Lmax | L90 | L10 | L50 | Leq | SEL | |
| Nurses handover (8:00-9:00 hours) | 83.9 ± 4.1 | 59.4 ± 2.3 | 70.0 ± 2.0 | 64.7 ± 2.1 | 67.3 ± 1.9 | 99.8 ± 1.9 |
| Nurses handover (13:30-14:30 hours) | 83.7 ± 3.8 | 58.1 ± 2.1 | 69.1 ± 1.8 | 63.4 ± 2.3 | 66.3 ± 1.9 | 98.8 ± 1.9 |
| Nurses handover (20:00-21:00 hours) | 83.2 ± 3.7 | 58.5 ± 2.2 | 69.7 ± 1.7 | 64.1 ± 2.0 | 66.8 ± 1.7 | 99.4 ± 1.7 |
| Visiting time (12:30-13:00 hours) | 83.0 ± 4.4 | 58.6 ± 1.8 | 69.5 ± 1.9 | 64.1 ± 2.1 | 66.7 ± 2.0 | 99.2 ± 2.0 |
| Visiting time (17:00-17:30 hours) | 83.0 ± 4.0 | 57.6 ± 2.2 | 68.6 ± 2.0 | 62.9 ± 2.3 | 65.8 ± 2.0 | 98.4 ± 2.0 |
| Night time avg (22:00-6:00 hours) | 81.1 ± 4.8 | 54.8 ± 2.7 | 65.9 ± 3.2 | 59.4 ± 3.0 | 63.1 ± 3.0 | 95.7 ± 3.0 |
| Night time (1:00-2:00 hours) | 79.6 ± 4.6 | 54.0 ± 2.8 | 64.5 ± 3.5 | 58.2 ± 3.0 | 61.8 ± 2.8 | 94.3 ± 2.8 |
| Night time (2:00-3:00 hours) | 79.9 ± 4.7 | 54.1 ± 2.7 | 64.8 ± 3.5 | 58.3 ± 2.9 | 62.1 ± 2.8 | 94.6 ± 2.8 |
| Twilight (4:00-6:00 hours) | 83.7 ± 4.3 | 55.9 ± 2.5 | 67.7 ± 2.5 | 60.9 ± 2.6 | 65.1 ± 2.4 | 97.6 ± 2.4 |
Table 3 Maximum sound level recordings above 75 dB and 85 dB during nurses’ handover, visiting, night time and twilight, n (%)
| Number of recordings | Events exceeding 75 dB | Events exceeding 85 dB | |
| Nurses’ handover (morning, afternoon, night) | 679 | 679 (100) | 218 (32) |
| Visiting (morning and evening) | 114 | 113 (99) | 38 (33) |
| Night time (22:00-6:00 hours) | 1134 | 1006 (89) | 143 (13) |
| Twilight (4:00-6:00 hours) | 450 | 445 (99) | 155 (34) |