Table 1 Comparison of surgical-related indicators between two groups
| Characteristic | Group | mean ± SD | P value |
| Time duration (minute) | Group 1 | 5.20 ± 2.608 | < 0.001 |
| Group 2 | 10.55 ± 4.828 | ||
| Suturing length (cm) | Group 1 | 19.20 ± 4.175 | < 0.001 |
| Group 2 | 29.20 ± 4.336 | ||
| Wound size to suturing time ratio | Group 1 | 2.74 ± 0.571 | < 0.001 |
| Group 2 | 1.34 ± 0.197 | ||
| Suturing removal time (minute) | Group 1 | 2.65 ± 0.875 | < 0.001 |
| Group 2 | 4.70 ± 1.174 | ||
| Wound size/removal time | Group 1 | 4.99 ± 0.895 | < 0.001 |
| Group 2 | 2.76 ± 0.471 |
- Citation: Sadiq M, Neerudi SR, Kasam RR, Koribilli SP, Naik VRS, Naik BD, Singh PK, Manne A, Kothalanka UK, Mettu AK, Nunnabatla K, Ale SK, Mallepogu KK, Bebartta SP. Comparative study between combined oblique and vertical everting running stitch and the conventional suturing technique. World J Orthop 2025; 16(12): 112435
- URL: https://www.wjgnet.com/2218-5836/full/v16/i12/112435.htm
- DOI: https://dx.doi.org/10.5312/wjo.v16.i12.112435