        World J Orthop. Oct 18, 2020; 11(10): 442-452
Published online Oct 18, 2020. doi: 10.5312/wjo.v11.i10.442
Published online Oct 18, 2020. doi: 10.5312/wjo.v11.i10.442
            Table 1 Inclusion and exclusion criteria
        
    | Inclusion | Exclusion | 
| Primary arthroplasty due to: | Patients who recently suffered: | 
| Primary osteoarthritis | Post-operative osteoarthritis | 
| Avascular necrosis | Charnley C osteoarthritis | 
| Femoral neck fracture | Infection of the hip | 
| Hip dysplasia | |
| Age between 60 - 75 yr at surgery | Prior osteotomy or arthroplasty of the affected hip | 
| Willing to comply with the post-operative review program | Under treatment for osteoporosis | 
| Body mass index > 35 kg/m2 | |
| Requiring cortisone medication | 
            Table 2 Patient and baseline characteristics
        
    | Conventional PE | REXPOL | |
| Number of patients, n (%) | 25 (49) | 26 (51) | 
| Gender, n (%) | ||
| Male | 10 (40) | 10 (39) | 
| Female | 15 (60) | 16 (59) | 
| BMI, mean ± SD kg/m2 | 26.7 ± 2.9 | 27.2 ± 3.4 | 
| Age at operation in years, mean ± SD | 68.5 ± 4.6 | 68.6 ± 5.1 | 
| HOOS pain, mean ± SD | 46.5 ± 21.6 | 51.1 ± 17.7 | 
| HOOS ADL, mean ± SD | 41.1 ± 16.6 | 46.0 ± 17.2 | 
| HHS, mean ± SD | 50.6 ± 12.7 | 54.6 ± 10.9 | 
            Table 3 Total wear in all directions at the five-year follow-up, presented as mean with ranges
        
    | Conventional PE (Polyethylene) | REXPOL | P value | |
| Medial (mm) | -0.128 (-0.202 to -0.054) | 0.013 (-0.054 to 0.081) | 0.006 | 
| Proximal (mm) | 0.196 (0.054 to 0.338) | 0.017 (-0.120 to 0.154) | 0.07 | 
| Volume (mm3) | 113.39 (-2.48 to 229.26) | -30.59 (-167.16 to 105.98) | 0.10 | 
| Corrected volume (mm3) | 121.6 (17.76 to 225.46) | -12.45 (-122.94; 98.03) | 0.07 | 
            Table 4 Mean wear rates per year, presented as mean with ranges
        
    | Conventional PE (Polyethylene) | P value | REXPOL | P value | |
| Medial (mm/yr) | -0.021 (-0.028 to -0.015) | < 0.001 | 0.004 (-0.002 to 0.009) | 0.21 | 
| Proximal (mm/yr) | 0.033 (0.018 to 0.047) | < 0.001 | 0.003 (-0.011 to 0.017) | 0.66 | 
| Volume (mm3/yr) | 15.94 (2.729 to 29.15) | 0.02 | -5.545 (-20.36 to 9.269) | 0.46 | 
| Corrected volume (mm3/yr) | 18.53 (7.188 to 29.86) | 0.002 | -2.142 (-14.13 to 9.841) | 0.72 | 
            Table 5 Functional outcomes at the five-year follow-up, presented as mean with 95%CI
        
    | Univariate | Multivariate | ||||
| Conventional PE (n = 17) | REXPOL (n = 17) | P value | Adjusted β-coefficient | P value | |
| HOOS pain | 93.8 (86.8; 100) | 85.9 (77.1; 94.7) | 0.15 | -3.3 (-14.9; 8.3) | 0.57 | 
| HOOS ADL | 89.0 (81.2: 96.8) | 77.6 (66.6; 88.5) | 0.08 | -8.6 (-23.3; 6.1) | 0.24 | 
| HHS | 89.7 (83.0; 96.4) | 86.5 (78.8; 94.2) | 0.51 | 0.15 (-10.1; 10.4) | 0.98 | 
- Citation: van Loon J, Hoornenborg D, Sierevelt I, Opdam KT, Kerkhoffs GM, Haverkamp D. Highly cross-linked versus conventional polyethylene inserts in total hip arthroplasty, a five-year Roentgen stereophotogrammetric analysis randomised controlled trial. World J Orthop 2020; 11(10): 442-452
- URL: https://www.wjgnet.com/2218-5836/full/v11/i10/442.htm
- DOI: https://dx.doi.org/10.5312/wjo.v11.i10.442

 
         
                         
                 
                 
                 
                 
                 
                         
                         
                        