BPG is committed to discovery and dissemination of knowledge
Cited by in CrossRef
For: Atkins GJ, Haynes DR, Howie DW, Findlay DM. Role of polyethylene particles in peri-prosthetic osteolysis: A review. World J Orthop 2011; 2(10): 93-101 [PMID: 22474627 DOI: 10.5312/wjo.v2.i10.93]
URL: https://www.wjgnet.com/2218-5836/full/v2/i10/93.htm
Number Citing Articles
1
Pedro Hinarejos, Ignasi Piñol, Alberto Torres, Eva Prats, Gabriel Gil-Gómez, Lluis Puig-Verdie. Highly Crosslinked Polyethylene Does Not Reduce the Wear in Total Knee ArthroplastyThe Journal of Arthroplasty 2013; 28(8) doi: 10.1016/j.arth.2013.01.026
2
Seung-Ju Kim, Dong-Geun Kang, Sung Bae Park, Jong Hun Kim. Is Hemiresurfacing Arthroplasty for Osteonecrosis of the Hip a Viable Solution?The Journal of Arthroplasty 2015; 30(6) doi: 10.1016/j.arth.2015.01.018
3
Jian Su, Jianjun Wang, Shitong Yan, Min Zhang, Ningze Zhang, Yichao Luan, Cheng-Kung Cheng. Wear Analysis of Tibial Inserts Made of Highly Cross-Linked Polyethylene Supplemented with Dodecyl Gallate before and after Accelerated AgingPolymers 2022; 14(23) doi: 10.3390/polym14235281
4
Sulev Koks, David J. Wood, Ene Reimann, Friedemann Awiszus, Christoph H. Lohmann, Jessica Bertrand, Ele Prans, Katre Maasalu, Aare Märtson. The Genetic Variations Associated With Time to Aseptic Loosening After Total Joint ArthroplastyThe Journal of Arthroplasty 2020; 35(4) doi: 10.1016/j.arth.2019.11.004
5
Muhammad Imam Ammarullah, Muhammad Kozin, Mohamad Izzur Maula, M. Danny Pratama Lamura, Hasyid Ahmad Wicaksono, Athanasius Priharyoto Bayuseno, Jamari Jamari, Muhammad Hanif Ramlee. A review of enhanced total hip prosthesis design and material bearing combination to accommodate Muslim prayer (Salat) movements: Biomechanical, biotribological, and biological perspectivesTribology International 2025; 205 doi: 10.1016/j.triboint.2025.110518
6
Kenichi Saiga, Masayuki Kyomoto, Kenichi Watanabe, Shuji Taketomi, Yuho Kadono, Yoshio Takatori, Sakae Tanaka, Kazuhiko Ishihara, Toru Moro. Effects of Material Thickness and Surface Modification of Cross-linked Polyethylene with Poly(2-Methacryloyloxyethyl Phosphorylcholine) on Its Deformation Behavior, Wear Resistance, and Durability Under Repetitive Impact-to-sliding MotionBiotribology 2017; 10 doi: 10.1016/j.biotri.2017.03.005
7
Renee T. Ormsby, Melissa Cantley, Masakazu Kogawa, L. Bogdan Solomon, David R. Haynes, David M. Findlay, Gerald J. Atkins. Evidence that osteocyte perilacunar remodelling contributes to polyethylene wear particle induced osteolysisActa Biomaterialia 2016; 33 doi: 10.1016/j.actbio.2016.01.016
8
Andrew S. Murtha, Marcel E. Roy, Leo A. Whiteside, David S. Tilden, Krystal L. Schmitt. Thin-Walled Cross-Linked Acetabular Liners Need Not Exhibit Reduced Locking StrengthOrthopedics 2015; 38(8) doi: 10.3928/01477447-20150804-62
9
Jung-Wee Park, Chong Bum Chang, Young-Kyun Lee, Jooyeon Suh, Jungsung Kim, Taejin Shin, YongHwa Kim, Donghyun Kang, Jin-Hong Kim, Stuart Barry Goodman. Mitigating polyethylene-mediated periprosthetic tissue inflammation through MEDSAH-graftingPLOS ONE 2024; 19(6) doi: 10.1371/journal.pone.0301618
10
Erhan Sukur, Yunus Emre Akman, Yusuf Ozturkmen, Fatih Kucukdurmaz. Particle Disease: A Current Review of the Biological Mechanisms in Periprosthetic Osteolysis After Hip ArthroplastyThe Open Orthopaedics Journal 2016; 10(1) doi: 10.2174/1874325001610010241
11
Naoto Saito, Hisao Haniu, Yuki Usui, Kaoru Aoki, Kazuo Hara, Seiji Takanashi, Masayuki Shimizu, Nobuyo Narita, Masanori Okamoto, Shinsuke Kobayashi, Hiroki Nomura, Hiroyuki Kato, Naoyuki Nishimura, Seiichi Taruta, Morinobu Endo. Safe Clinical Use of Carbon Nanotubes as Innovative BiomaterialsChemical Reviews 2014; 114(11) doi: 10.1021/cr400341h
12
Saverio Affatato. Perspectives in Total Hip Arthroplasty2014;  doi: 10.1533/9781782420392.2.117
13
Michael T. Hirschmann. The Unhappy Total Knee Replacement2015;  doi: 10.1007/978-3-319-08099-4_2
14
E. Alias, A.S.S.K. Dharmapatni, A.C. Holding, G.J. Atkins, D.M. Findlay, D.W. Howie, T.N. Crotti, D.R. Haynes. Polyethylene particles stimulate expression of ITAM-related molecules in peri-implant tissues and when stimulating osteoclastogenesis in vitroActa Biomaterialia 2012; 8(8) doi: 10.1016/j.actbio.2012.04.037
15
Oliver N. Schipper, Steven L. Haddad, Peter Pytel, Ying Zhou. Histological Analysis of Early Osteolysis in Total Ankle ArthroplastyFoot & Ankle International 2017; 38(4) doi: 10.1177/1071100716682333
16
Hanna Sikora, Jadwiga Gabor, Robert Roczniok, Damian Kusz, Andrzej Swinarew. The Measurement of the Oxidative Index of Polyethylene Obtained during Revision Hip Arthroplasty and Assessment of Its Variability Depending on the Degree of Osteolysis, Implantation Time, as Well as the Size and Material of the Utilized HeadJournal of Clinical Medicine 2024; 13(10) doi: 10.3390/jcm13102751
17
Qingliang Wang, Qihao Zheng, Yong Luo, Wenyin Huang. Torsion Wear Behavior of PEEK-on-UHMWPE as an All-Polymer Joint Combination in Total Knee ReplacementTribology Transactions 2022; 65(2) doi: 10.1080/10402004.2022.2029995
18
Yongwen Guo, Jun Guo, Ding Bai, Hang Wang, Xiaohui Zheng, Weihua Guo, Weidong Tian. Hemiarthroplasty of the Shoulder Joint Using a Custom‐Designed High‐Density Nano‐Hydroxyapatite/Polyamide Prosthesis With a Polyvinyl Alcohol Hydrogel Humeral Head Surface in RabbitsArtificial Organs 2014; 38(7) doi: 10.1111/aor.12257
19
Lauter E. Pelepenko, Mariana Cassani de Oliveira, Daniela A. Masaro, Glauco M. M. M. Lustosa, Talita Mazon, Roger F. Castilho, Luciene M. dos Reis, Fabrice Mac-Way, Lucie Hénaut, Saïd Kamel, Loïc Louvet, Rodrigo B. Oliveira. Effects of microplastics on the bones: a comprehensive reviewOsteoporosis International 2025; 36(8) doi: 10.1007/s00198-025-07580-4
20
Joseph A.S. McCahon, Tyler Radack, Hope Thalody, Adam Lencer, Tiffany Bridges, Tara G. Moncman, David I. Pedowitz, Selene G. Parekh, Joseph N. Daniel. Mid- to Long-Term In Vivo Polyethylene Wear Rates in Salto Talaris Total Ankle ArthroplastyFoot & Ankle International 2025; 46(7) doi: 10.1177/10711007251336752
21
Christina I. Esposito, Rema A. Oliver, Patricia A. Campbell, Yan Yu, William L. Walter, William K. Walter, William R. Walsh. Human polyethylene granuloma tissues inhibit bone healing in a novel xenograft animal modelJournal of Orthopaedic Research 2014; 32(6) doi: 10.1002/jor.22588
22
Matej Daniel, Boris Rijavec, Drago Dolinar, David Pokorný, Aleš Iglič, Veronika Kralj-Iglič. Patient-specific hip geometry has greater effect on THA wear than femoral head sizeJournal of Biomechanics 2016; 49(16) doi: 10.1016/j.jbiomech.2016.10.030
23
Jenna M. Wahbeh, Sang-Hyun Park, Patricia Campbell, Edward Ebramzadeh, Sophia N. Sangiorgio. The lexicon for periprosthetic bone loss versus osteolysis after cervical disc arthroplasty: a systematic reviewEuropean Spine Journal 2022; 31(4) doi: 10.1007/s00586-021-07092-9
24
Ji Lin, Carolyn M. Sofka, Constantine A. Demetracopoulos, Hollis G. Potter. The Utility of Isotropic 3D Magnetic Resonance Imaging in Assessing Painful Total Ankle ReplacementsFoot & Ankle Orthopaedics 2022; 7(2) doi: 10.1177/24730114221094840
25
Nur Shukriyah Mohamad Hazir, Nor Hamdan Mohamad Yahaya, Muhamad Syahrul Fitri Zawawi, Hanafi Ahmad Damanhuri, Norazlina Mohamed, Ekram Alias. Changes in Metabolism and Mitochondrial Bioenergetics during Polyethylene-Induced OsteoclastogenesisInternational Journal of Molecular Sciences 2022; 23(15) doi: 10.3390/ijms23158331
26
Janosch Schoon, Anastasia Rakow. AE-Manual der EndoprothetikSpringer Reference Medizin 2023;  doi: 10.1007/978-3-662-55485-2_53-1
27
Julia F. Charles, Mary C. Nakamura. Bone and the Innate Immune SystemCurrent Osteoporosis Reports 2014; 12(1) doi: 10.1007/s11914-014-0195-2
28
Liangzi Yin, Chenglin Sun, Junjie Zhang, Yan Li, Yansheng Wang, Lunhao Bai, Zeming Lei. Critical signaling pathways in osteoclast differentiation and bone resorption: mechanisms and therapeutic implications for periprosthetic osteolysisFrontiers in Cell and Developmental Biology 2025; 13 doi: 10.3389/fcell.2025.1639430
29
Renee T. Ormsby, Lucian B. Solomon, Roumen Stamenkov, David M. Findlay, Gerald J. Atkins. Evidence for Gender-Specific Bone Loss Mechanisms in Periprosthetic OsteolysisJournal of Clinical Medicine 2019; 9(1) doi: 10.3390/jcm9010053
30
Janosch Schoon, Anastasia Rakow. Endoprothetik der Hüfte2024;  doi: 10.1007/978-3-662-68617-1_53
31
Alexander D. Kamenskiy, Yurii V. Parakhin, Mikhail V. Parshikov. Key pathogenetic components of aseptic loosening of joint prosthesesN.N. Priorov Journal of Traumatology and Orthopedics 2025; 33(2) doi: 10.17816/vto678098
32
A. F Kolondaev, A. V Balberkin, N. V Zagorodniy. Fifty Years of Ultra High Molecular Polyethylene Use in Total Joint Replacement. Success, Problems, PerspectivesN.N. Priorov Journal of Traumatology and Orthopedics 2012; 19(4) doi: 10.17816/vto20120485-94
33
Bolun Wang, Haohui Guo, Tianxiang Geng, Kening Sun, Liang Zhang, Zhidong Lu, Qunhua Jin. The effect of strontium ranelate on titanium particle-induced periprosthetic osteolysis regulated by WNT/β-catenin signaling in vivo and in vitro Bioscience Reports 2021; 41(1) doi: 10.1042/BSR20203003
34
Matthew Prideaux, Lynda F. Bonewald. Encyclopedia of Bone Biology2020;  doi: 10.1016/B978-0-12-801238-3.11203-6
35
Renee T. Ormsby, Lucian B. Solomon, Dongqing Yang, Tania N. Crotti, David R. Haynes, David M. Findlay, Gerald J. Atkins. Osteocytes respond to particles of clinically-relevant conventional and cross-linked polyethylene and metal alloys by up-regulation of resorptive and inflammatory pathwaysActa Biomaterialia 2019; 87 doi: 10.1016/j.actbio.2019.01.047
36
Studies in Natural Products Chemistry 2017; 52 doi: 10.1016/B978-0-444-63931-8.00009-6
37
Jana Markhoff, Carmen Zietz, Christian Fabry, Gerhard Fulda, Rainer Bader. Influence of analyzed lubricant volumes on the amount and characteristics of generated wear particles from three different types of polyethylene liner materialsJournal of Biomedical Materials Research Part B: Applied Biomaterials 2018; 106(3) doi: 10.1002/jbm.b.33944
38
Michael M. Schündeln, Jakob Höppner, Felix L. Meyer, Wiebke Schmuck, Max D. Kauther, Gero Hilken, Bodo Levkau, Martina Rauner, Corinna Grasemann. Prednisone prevents particle induced bone loss in the calvaria mouse modelHeliyon 2021; 7(8) doi: 10.1016/j.heliyon.2021.e07828
39
A. Impergre, A.M. Trunfio-Sfarghiu, C. Der-Loughian, L. Brizuela, S. Mebarek, B. Ter-Ovanessian, A. Bel-Brunon, Y. Berthier, B. Normand. Tribocorrosion of Polyethylene/Cobalt Contact Combined with Real-Time Fluorescence Assays on Living Macrophages: Development of A Multidisciplinary Biotribocorrosion DeviceBiotribology 2019; 18 doi: 10.1016/j.biotri.2019.100091
40
Pedro Hinarejos Gomez, Ignasi Pinol Jurado. Tribology in Total Hip and Knee Arthroplasty2014;  doi: 10.1007/978-3-642-45266-6_6
41
Yanling Li, Ling Zhang, Jian Wang, Ying Zheng, Jian Cui, Guifeng Yuan. Tanshinone IIA attenuates polyethylene-induced osteolysis in a mouse model: The key role of miR-155-5p/FOXO3 axisJournal of Functional Foods 2021; 87 doi: 10.1016/j.jff.2021.104784
42
Frank Van Praet, Michiel Mulier. To cement or not to cement acetabular cups in total hip arthroplasty: a systematic review and re-evaluationSICOT-J 2019; 5 doi: 10.1051/sicotj/2019032
43
Isabelle Catelas, Eric A. Lehoux, Zhibin Ning, Daniel Figeys, Stephen J. Baskey, Paul E. Beaulé. Differential proteomic analysis of synovial fluid from hip arthroplasty patients with a pseudotumor vs. Periprosthetic osteolysis Journal of Orthopaedic Research 2018; 36(7) doi: 10.1002/jor.23858
44
Kuo-Ti Peng, Meng-Hsueh Tsai, Chiang-Wen Lee, Yao-Chang Chiang, Pei-Chun Chen, Chun-Chieh Chen, Chih-Hsiang Chang, Hsin-Nung Shih, Pey-Jium Chang, Salah A Sheweita. Dysregulated expression of antioxidant enzymes in polyethylene particle-induced periprosthetic inflammation and osteolysisPLOS ONE 2018; 13(8) doi: 10.1371/journal.pone.0202501
45
Cristina Sobacchi, Eleonora Palagano, Ciro Menale. Handbook of Biomaterials Biocompatibility2020;  doi: 10.1016/B978-0-08-102967-1.00027-X
46
L. Lapaj, J. Markuszewski, T. Rybak, A. A. Britsko, V. V. Anosov, M. Wierusz-Kozlowska. Wear analysis of a ceramic on ceramic hip endoprosthesisJournal of Friction and Wear 2013; 34(1) doi: 10.3103/S106836661301008X
47
Andrew R. Hsu, Steven L. Haddad, Mark S. Myerson. Evaluation and Management of the Painful Total Ankle ArthroplastyJournal of the American Academy of Orthopaedic Surgeons 2015; 23(5) doi: 10.5435/JAAOS-D-14-00017
48
Kirill Gromov, Nanna H Sillesen, Thomas Kallemose, Henrik Husted, Henrik Malchau, Anders Troelsen. Safety of vitamin E-infused highwall liners for routine use in primary total hip arthroplasty: single centre, short-term follow-up of 1221 casesHIP International 2022; 32(1) doi: 10.1177/1120700020969644
49
D. Rick Sumner, Ryan Ross, Ed Purdue. Are There Biological Markers for Wear or Corrosion? A Systematic ReviewClinical Orthopaedics and Related Research® 2014; 472(12) doi: 10.1007/s11999-014-3580-3
50
Zhe Yi, Ying Liu, Yidan Ma, Zhaogang Liu, Hui Sun, Xing Zhou, Rui Kang, V.A.M. Cristino, Qiang Wang. Surface treatment of 3D printed Cu-bearing Ti alloy scaffolds for application in tissue engineeringMaterials & Design 2022; 213 doi: 10.1016/j.matdes.2021.110350
51
Luis Alberto Cordova, Verena Stresing, Bérengère Gobin, Philippe Rosset, Norbert Passuti, François Gouin, Valérie Trichet, Pierre Layrolle, Dominique Heymann. Orthopaedic implant failure: aseptic implant loosening–the contribution and future challenges of mouse models in translational researchClinical Science 2014; 127(5) doi: 10.1042/CS20130338