Sawaya FJ, Spaziano M, Lefèvre T, Roy A, Garot P, Hovasse T, Neylon A, Benamer H, Romano M, Unterseeh T, Morice MC, Chevalier B. Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves: A single-center experience. World J Cardiol 2016; 8(12): 735-745 [PMID: 28070241 DOI: 10.4330/wjc.v8.i12.735]
Corresponding Author of This Article
Bernard Chevalier, MD, Department of Cardiology, Générale de Santé, Institut Cardiovasculaire Paris-Sud - Hôpital Privé Jacques Cartier, 6 Avenue du Noyer Lambert, 91300 Massy, France. bchevali@aol.com
Research Domain of This Article
Cardiac & Cardiovascular Systems
Article-Type of This Article
Retrospective Study
Open-Access Policy of This Article
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Table 5 Electrocardiographic and angiographic characteristics according to new permanent pacemaker requirement in the SAPIEN 3 transcatheter heart valve group
Variable
New PPM (n = 43)
No PPM (n = 201)
P value
Complete RBBB
12 (32.4)
17 (9.5)
0.001
Complete LBBB
0 (0)
14 (7.8)
0.14
Fascicular block
12 (32.4)
33 (18.4)
0.07
QRS duration, ms
108 ± 26
101 ± 23
0.1
PR duration, ms
196 ± 37
183 ± 30
0.04
Implant depth (septal), mm
5.3 ± 2.4
5.0 ± 2.6
0.67
Implant depth (non-septal), mm
4.9 ± 2.4
5.2 ± 1.9
0.64
Device lack of coaxiality during deployment, mm
4.0 ± 3.6
2.9 ± 2.5
0.06
Table 6 Predictors of new pacemaker implantation in the S3 group
Parameter
Univariate analysis
Multivariate analysis
OR
P value
OR
95%CI
P value
Complete RBBB
4.6
< 0.001
4.9
1.88-12.95
0.001
Complete LBBB
1
1
-
-
-
Fascicular block
2.12
0.06
1.88
0.71-5.00
0.2
QRS duration (per 10 ms increment)
1.12
0.1
0.87
0.65-2.72
0.345
PR duration (per 10 ms increment)
1.14
0.05
1.14
1.00-1.29
0.05
Implant depth (septal, per 1 mm increment)
1.05
0.66
-
-
-
Implant depth (non-septal, per 1 mm increment)
0.94
0.63
-
-
-
Device lack of coaxiality during implant (per 1 mm increment)
1.13
0.07
1.13
1.00-1.29
0.049
Table 7 Summary of studies comparing the rate of permanent pacemaker between the S3 and XT device
High implants: 80/20 in aorta as mentioned by authors
Citation: Sawaya FJ, Spaziano M, Lefèvre T, Roy A, Garot P, Hovasse T, Neylon A, Benamer H, Romano M, Unterseeh T, Morice MC, Chevalier B. Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves: A single-center experience. World J Cardiol 2016; 8(12): 735-745