Age | Event | Work up |
0 months | Diagnosis of tetralogy of Fallot | Tracking |
18 months | Tetralogy of Fallot correction | Infundibular patching and correction of IVC |
11 years | Onset of high-exertional dyspnea | Tracking |
14 years | Echocardiogram and MRI showed pulmonary insufficiency severe and main stenosis | A transcatheter pulmonary valve prosthesis replacement |
15 years | Incidental findings of diverticulum in right ventricle | Post-surgical follow-up with CMR |
- Citation: Martinez Juarez D, Gomez Monterrosas O, Tlecuitl Mendoza A, Zamora Rosales F, Álvarez Calderón R, Cepeda Ortiz DA, Espinosa Solis EE. Right ventricular diverticulum following a pulmonary valve placement for correction of tetralogy of Fallot: A case report. World J Cardiol 2024; 16(12): 760-767