Published online Nov 26, 2023. doi: 10.4330/wjc.v15.i11.582
Peer-review started: May 17, 2023
First decision: July 19, 2023
Revised: August 18, 2023
Accepted: October 17, 2023
Article in press: October 17, 2023
Published online: November 26, 2023
Processing time: 189 Days and 13.3 Hours
Conduction and rhythm abnormalities requiring permanent pacemakers (PPM) are short-term complications following transcatheter aortic valve replacement (TAVR), and their clinical outcomes remain conflicting. Potential novel predictors of post-TAVR PPM, like QRS duration, QTc prolongation, and supraventricular arrhythmias, have been poorly studied.
To evaluate the effects of baseline nonspecific interventricular conduction delay and supraventricular arrhythmia on post-TAVR PPM requirement and determine the impact of PPM implantation on clinical outcomes.
A retrospective cohort study that identified patients with TAVR between January 1, 2012 to December 31, 2019. The group was dichotomized into those with post-TAVR PPM and those without PPM. Both groups were followed for one year.
Out of the 357 patients that met inclusion criteria, the mean age was 80 years, 188 (52.7%) were male, and 57 (16%) had a PPM implantation. Baseline demographics, valve type, and cardiovascular risk factors were similar except for type II diabetes mellitus (DM), which was more prevalent in the PPM cohort (59.6% vs 40.7%; P = 0.009). The PPM cohort had a significantly higher rate of pre-procedure right bundle branch block, prolonged QRS > 120 ms, prolonged QTc > 470 ms, and supraventricular arrhythmias. There was a consistently significant increase in the odds ratio (OR) of PPM implantation for every 20 ms increase in the QRS duration above 100 ms: QRS 101-120 [OR: 2.44; confidence intervals (CI): 1.14-5.25; P = 0.022], QRS 121-140 (OR: 3.25; CI: 1.32-7.98; P = 0.010), QRS 141-160 (OR: 6.98; CI: 3.10-15.61; P < 0.001). After model adjustment for baseline risk factors, the OR remained significant for type II DM (aOR: 2.16; CI: 1.18-3.94; P = 0.012), QRS > 120 (aOR: 2.18; CI: 1.02-4.66; P = 0.045) and marginally significant for supraventricular arrhythmias (aOR: 1.82; CI: 0.97-3.42; P = 0.062). The PPM cohort had a higher adjusted OR of heart failure (HF) hospitalization (aOR: 2.2; CI: 1.1-4.3; P = 0.022) and nonfatal myocardial infarction (MI) (aOR: 3.9; CI: 1.1-14; P = 0.031) without any difference in mortality (aOR: 1.1; CI: 0.5-2.7; P = 0.796) at one year.
Pre-TAVR type II DM and QRS duration > 120, regardless of the presence of bundle branch blocks, are predictors of post-TAVR PPM. At 1-year post-TAVR, patients with PPM have higher odds of HF hospitalization and MI.
Core Tip: This study found that patients with pre-transcatheter aortic valve replacement (TAVR) type 2 diabetes mellitus and QRS duration > 120 ms regardless of the presence of right or left bundle branch block, are at increased risk of permanent pacemaker implantation post-TAVR. The study also demonstrated a linear association between post-TAVR permanent pacemakers (PPM) incidence for every 20 ms prolongation in QRS duration > 100 ms. The study also showed post-TAVR PPM is associated with greater risks of heart failure hospitalization and non-fatal myocardial infarction in our study cohort. In light of the expanded indication of TAVR and the clinical and economic impact of PPM implantation, multidisciplinary heart teams should meticulously risk stratify pre-TAVR patients regarding PPM requirements using novel evidence.
- Citation: Nwaedozie S, Zhang H, Najjar Mojarrab J, Sharma P, Yeung P, Umukoro P, Soodi D, Gabor R, Anderson K, Garcia-Montilla R. Novel predictors of permanent pacemaker implantation following transcatheter aortic valve replacement. World J Cardiol 2023; 15(11): 582-598
- URL: https://www.wjgnet.com/1949-8462/full/v15/i11/582.htm
- DOI: https://dx.doi.org/10.4330/wjc.v15.i11.582
Patients with untreated symptomatic severe aortic valve stenosis within the first two years have 50% mortality[1]. Transcatheter aortic valve replacement (TAVR) has emerged as a less invasive therapeutic option with proven survival benefits for the management of these patients regardless of their surgical risks after evaluation by a multidisciplinary heart valve team[2,3]. Since the TAVR idea was conceptualized in 1989 and the first-in-human procedure successfully performed thirteen years later by Alain Cribier in France, TAVR procedure has caused a therapeutic paradigm shift, is a safer, non-inferior alternative to surgical aortic valve replacement which is contraindicated in about a third of patients due to prohibitive surgical risks[4-8].
Despite improvement in TAVR procedure techniques over the last two decades to optimize patient safety, cardiac conduction abnormalities requiring permanent pacemakers (PPM) implantation are some post-TAVR complications observed in about 5%-20% of patients[7,9-11]. These conduction abnormalities have been shown to be dependent on patient and periprocedural factors[6,8,9-12]. The atrioventricular (AV) conduction system courses posterior-inferiorly to the non-coronary cusp of the aortic valve annulus as it passes through the membranous septum and the central fibrous body as the bundle of HIS before bifurcation as it enters the interventricular septum[12,13]. This anatomic proximity of the conduction system to the aortic annulus and subarticular region poses a risk of a procedural, mechanical injury during TAVR through direct trauma during catheter insertion, balloon pre-dilation, valve deployment, or peri-implantation swelling[10,14-16]. The resultant post-procedural electrical conduction abnormalities, though may be transient and self-resolving, sometimes may require permanent pacemaker implantation[15,17]. The prevalence of these conduction abnormalities can vary depending on the valve type implanted and have been shown to be more common with the self-expandable Medtronic CoreValve revealing system (MRCS) with a 24%-33% PPM implantation rate compared to the balloon-expandable Edwards Sapien valve (ESV) (5%-12%)[6,8,16]. The flaring, self-expanding nature coupled with the greater radial force generated when deploying the MRCS has been thought to contribute to a higher rate of conduction abnormalities and pacemaker placement than balloon-expandable valves (BEV)[8,17].
In order to reliably risk-stratify patients with respect to post-TAVR pacemaker requirements, several studies have identified several pre-procedural, electrocardiographic (EKG), anatomic, and procedural factors that could predict pacemaker implantation. Although pre-existing conduction abnormalities like AV block, right bundle branch block (RBBB), left bundle branch block (LBBB), left anterior fascicular hem-block, potential risk factors like baseline QRS duration without RBBB or LBBB (nonspecific interventricular conduction delay), supraventricular arrhythmia or type 2 diabetes mellitus (DM) have not been well studied[6,8,12,16,18,19]. Also, although studies in non-TAVR patients have shown an association of isolated right ventricular pacemakers with adverse outcomes like increased heart failure (HF) hospitalization and mortality due to electro-mechanical dyssynchrony, studies on whether post-TAVR PPM patients is associated with adverse clinical outcomes have remained controversial[6,16,20-24].
Therefore, in this study, we intend to retrospectively evaluate the effects of baseline type 2 DM, nonspecific interventricular conduction delay, and supraventricular arrhythmia on post-TAVR PPM requirement and determine the impact of PPM implantation clinical outcomes in a tertiary referral center in Central Wisconsin, United States.
This retrospective cohort study included all patients who underwent TAVR for symptomatic aortic stenosis from January 1, 2012 to December 31, 2019. TAVR was offered to patients after evaluation by a comprehensive multidisciplinary heart team according to guideline requirements[25].
Preoperative risks were determined after a thorough review by interventional cardiologists and cardiothoracic surgeons, and patients were classified based on the Society of Thoracic Surgeons risk score for prediction of mortality[26]. Preoperative risk was classified into low risk (< 4%), intermediate-risk (4%-7%), and high risk (> 8%) or inoperable if the multidisciplinary heart team considered the patient inoperable for other clinical reasons. Only the first TAVR procedure during index hospitalization was considered. Patients with a prior history of PPM placement, international classification of disease (ICD) placement, unsuccessful procedures, who died during the procedure, and who had a conversion to open procedures were excluded from the study (Figure 1). The study population was then dichotomized into two cohorts: (1) Patients who required PPM post-TAVR within one year post-TAVR; and (2) Patients who did not require PPM. All the patients were followed up for one year.
The patients’ data were extracted both electronically and manually from the Marshfield Clinic health system (MCHS), electronic health records obtained by mapping with ICD versions 9 and 10 billing codes for TAVR. Baseline EKG and transthoracic echocardiographic data done within 1 mo prior to the TAVR procedure were manually abstracted by trained physicians after reviewing EKGs and transthoracic echocardiogram reports interpreted and approved by board-certified cardiologists. Similarly, postoperative EKG and echocardiographic data were abstracted from the first postoperative EKGs and complete transthoracic echocardiography, which was performed within one month post-TAVR. All other data were electronically abstracted. 15% of the manually and electronically abstracted data were re-verified by three independent physician reviewers and were found to be over 99% accurate. The MCHS IRB committee granted Institutional Review Board approval prior to patients’ electronic medical record review in accordance with the Code of Ethics of the World Medical Association (Declaration of Helsinki).
Baseline demographics, comorbid conditions, pre-procedural, intraprocedural, and post-procedural EKG and echocardiographic data were collected. Demographic data obtained included patient sex, age, and race. Some of the pre-procedure clinical characteristics obtained include body mass index (BMI), society of thoracic surgeons (STS) preoperative risk score, comorbidities like a history of atrial fibrillation, coronary artery disease (CAD), history of myocardial infarction (MI), HF, New York Heart Association (NYHA) class, coronary artery bypass graft, preoperative balloon valvuloplasty (BV), hypertension, diabetes, chronic obstructive pulmonary disease, cancer and others outlined in Table 1. Preprocedural and post-procedural EKG data collected include supraventricular arrhythmias (atrial fibrillation, atrial flutter, and junctional rhythm), conduction abnormalities like RBBB, LBBB, AV blocks, left anterior fascicular block, left posterior fascicular block, bifascicular or trifascicular blocks, intervals including P-R, QRS, QTc. Nonspecific interventricular conduction defect was defined at QRS > 120 ms without RBBB or LBBB morphology. Baseline and postprocedural transthoracic Echocardiographic variables obtained include aortic valve area, peak velocity, mean gradient, peak gradient, aortic valve mitral and tricuspid valve regurgitation, aortic annulus area, and sinus diameter, left ventricular ejection fraction (LVEF), pulmonary artery pressure, left ventricular diastolic diameter, and left ventricular outflow tract (LVOT). Preoperative computed tomography (CT) annulus diameter was also obtained.
Characteristics | No PPM | PPM | P value |
n = 300 (%) | n = 57 (%) | ||
Age | 81.0 (8.2) | 80.3 (7.6) | 0.530 |
Male | 158 (52.7) | 30 (52.6) | 1.00 |
BMI | 30.5 (6.6) | 31.4 (6.6) | 0.380 |
STS risk score | 0.168 | ||
High (≥ 8%) | 194 (64.7) | 41 (73.2) | |
Intermediate (4%-7%) | 72 (24) | 12 (21.4) | |
Low (< 4%) | 34 (11.3) | 3 (5.4) | |
Cardiovascular history | |||
AF | 128 (42.7) | 28 (49.1) | 0.385 |
CAD | 260 (86.7) | 51 (89.5) | 0.670 |
MI | 62 (20.7) | 16 (28.1) | 0.223 |
HF | 280 (93.3) | 54 (94.7) | 1.00 |
NYHA HF class | 0.495 | ||
1 | 4 (1.5) | 1 (1.9) | |
2 | 101 (38.1) | 18 (34) | |
3 | 148 (55.8) | 30 (56.6) | |
4 | 12 (4.5) | 4 (7.5) | |
PCI or stent | 134 (44.7) | 29 (50.9) | 0.469 |
CABG | 47 (15.7) | 13 (22.8) | 0.182 |
Previous AV replacement | 24 (8.0) | 1 (1.8) | 0.151 |
Hypertension | 284 (94.7) | 56 (98.2) | 0.493 |
Dyslipidemia | 271 (90.3) | 51 (89.5) | 0.810 |
Diabetes | 122 (40.7) | 34 (59.6) | 0.009 |
PVD | 73 (24.3) | 20 (35.1) | 0.101 |
Stroke/TIA | 32 (10.7) | 8 (14) | 0.491 |
Balloon valvuloplasty | 149 (50) | 35 (62.5) | 0.108 |
Other comorbidities | |||
COPD | 89 (29.7) | 11 (19.3) | 0.147 |
Liver disease | 4 (1.3) | 1 (1.8) | 0.583 |
Cancer | 142 (47.3) | 26 (45.6) | 0.885 |
Anemia | 259 (86.3) | 51 (89.5) | 0.670 |
Dialysis | 15 (5) | 4 (7) | 0.521 |
The valve index, which is a relation of the valve size in relation to the aortic annulus, was calculated as valve size/LVOT diameter × 100[27,28]. Other periprocedural variables obtained include procedure urgency, valve type (BEV and SEV), valve size, access site, and post procedure complications.
The patients were followed up one year postprocedure and clinical outcome data were evaluated at in-hospital, 30-d, and at 1-year post-TAVR. In-hospital outcomes data included length of hospital stay. 30-d and 1-year outcomes studied will include all-cause mortality, HF admission, and hospitalization for MI or stroke as defined by the Valve Academic Research Consortium two endpoint criteria[29-34]. The causes of mortality were also evaluated to determine whether they were cardiovascular or non-cardiovascular.
Patient characteristics were described using mean ± SD for normal continuous variables, medians and interquartile range (IQR) for non-normal continuous variables, and counts and percentages for categorical and ordinal variables. Characteristics of patients who received PPM implantation within one year and those who did not receive PPM implantation within one year were compared using a t-test, Wilcoxon-rank sum test, Fisher’s exact test, or the Kruskal-Wallis test as appropriate.
Incidence of PPM implantation was reported by age group, sex, preoperative risk, valve type, prior BV, procedure time, preoperative EKG findings, QRS intervals, QTc intervals, and prior conduction defects. P values reported were derived from Fisher’s exact test or the Kruskal-Wallis test. Unadjusted odds ratios (OR) for PPM implantation were calculated for variables selected a priori, which were thought to be independently associated with pacemaker placement. Variables selected a priori with significant unadjusted OR and variables with P < 0.10 in a univariate comparison were considered for a multivariable logistic regression model to predict PPM implantation.
The collinearity between prior RBBB, QRS intervals, and QTc intervals was examined. Abnormal QRS intervals were strongly associated with PPM implantation among patients with RBBB but also among patients without RBBB. As such, we kept both terms in the model. Prolonged QTc interval also appeared to be a strong predictor of PPM implantation. However, there was not a significant association between QTc interval and PPM implantation after stratifying by abnormal QRS interval. Adjusted ORs, 95% confidence intervals (CI), and P values were reported. The significant P value was set to < 0.05.
Clinical outcomes at 30 d and one year were reported among patients with PPM implantation within one year and those without. The median length of stay was compared using a Wilcoxon rank-sum test. All other clinical outcomes were regressed on PPM and adjusted for patient characteristics that were significantly different at baseline (diabetes). Adjusted ORs, 95%CI, and P values were reported. Differences in survival in the year following TAVR by cohort (no PPM, PPM) were compared using Kaplan-Meier curves and a log-rank test.
The baseline demographic and clinical characteristics of the study cohort are presented in Table 1. The mean age of the population was 80.8 years, comparable for both cohorts (81.0 years for no PPM and 80.3 years for the PPM). 52.7% of the population were male, and the average BMI was 30.7 kg/m2. 66% of the population had a high operative risk (STS > 8%), which was comparable between the 2 populations. Over four-fifths had CAD (87.1%) and HF (93.6%), and two-thirds of the patients had at least NYHA class III HF. Besides type 2 DM, which was more common in the PPM cohort than the non-PPM cohort (59.6% vs 40.7%; P = 0.009), there were no differences in the comorbidities or cardiovascular risk factors, as shown in Table 1.
Baseline EKG and echocardiographic findings as shown in Table 2. Compared to patients without PPM, patients with PPM were found to be more likely to have a supraventricular arrhythmia (atrial fibrillation, atrial flutter, or junctional rhythm) (No PPM: 23.7%; vs PPM: 36.9%. P = 0.054). Baseline RBBB was found to be significantly higher in the PPM patients (No PPM: 11% vs PPM: 32%; P < 0.001). Prolonged QRS ≥ 120 ms and prolonged QTC (≥ 470 ms) were found to be higher in the PPM cohorts: (No PPM: 21% vs PPM: 47%, P < 0.001 and No PPM: 23% vs PPM: 47%, P < 0.001 respectively). There were no significant differences noted in the other conduction abnormalities noted. As shown in Table 2, there was no echocardiographic difference in baseline LVEF or other parameters.
All | No PPM | PPM | P value | |
n = 357 | n = 300 | n = 57 | ||
EKG rhythm abnormalities | 0.054 | |||
Sinus | 265 (74.2) | 229 (76.3) | 36 (63.2) | |
Atrial fibrillation | 84 (23.5) | 66 (22.0) | 18 (31.6) | |
Atrial flutter | 4 (1.1) | 2 (0.7) | 2 (3.5) | |
Junctional rhythm | 2 (0.6) | 1 (0.3) | 1 (1.8) | |
Other | 2 (0.6) | 2 (0.7) | 0 (0) | |
Sinus bradycardia | 38 (10.6) | 35 (11.7) | 3 (5.3) | 0.229 |
Sinus tachycardia | 3 (0.8) | 3 (1) | 0 (0) | 1.00 |
Conduction abnormalities | ||||
RBBB | 51 (14.3) | 33 (11) | 18 (31.6) | < 0.001 |
LBBB | 29 (8.1) | 24 (8) | 5 (8.8) | 0.794 |
AV block I | 55 (15.4) | 46 (15.3) | 9 (15.8) | 1.00 |
AV block IIa | 0 | 0 | 0 | - |
AV block IIb | 0 | 0 | 0 | - |
AV block III | 0 | 0 | 0 | - |
Bifascicular block | 5 (1.4) | 5 (1.7) | 0 (0) | 1.00 |
Left anterior fascicular block | 16 (4.5) | 12 (4) | 4 (7) | 0.299 |
Left posterior fascicular block | 1 (0.3) | 0 (0) | 1 (1.8) | 0.16 |
Abnormal QRS (≥ 120 ms) | 89 (25) | 62 (20.7) | 27 (47.4) | < 0.001 |
Prolonged QTc (≥ 470 ms) | 97 (27.2) | 70 (23.4) | 27 (47.4) | < 0.001 |
Echocardiogram findings | ||||
Left ventricular EF | 58.1 (12.7) | 58.5 (11.9) | 56 (16.1) | 0.272 |
AV peak velocity | 4.1 (0.7) | 4.1 (0.7) | 4.1 (0.7) | 0.957 |
AV mean gradient | 42 (14.7) | 42.1 (14.7) | 41.3 (14.8) | 0.707 |
AV peak gradient | 68.4 (21.9) | 68.4 (21.7) | 68.1 (23.2) | 0.933 |
AV regurgitation | 0.247 | |||
None | 147 (43.9) | 116 (41.6) | 31 (55.4) | |
Mild | 162 (48.4) | 141 (50.5) | 21 (37.5) | |
Moderate | 23 (6.9) | 19 (6.8) | 4 (7.1) | |
Severe | 3 (0.9) | 3 (1.1) | 0 (0) | |
MV regurgitation | 0.242 | |||
None | 28 (8.2) | 24 (8.4) | 4 (7.1) | |
Mild | 255 (74.8) | 208 (73.0) | 47 (83.9) | |
Moderate | 52 (15.2) | 48 (16.8) | 4 (7.1) | |
Severe | 6 (1.8) | 5 (1.8) | 1 (1.8) | |
TV regurgitation | 0.129 | |||
None | 19 (5.6) | 19 (6.6) | 0 (0) | |
Mild | 272 (79.8) | 226 (79.0) | 46 (83.6) | |
Moderate | 43 (12.6) | 36 (12.6) | 7 (12.7) | |
Severe | 7 (2.1) | 5 (1.7) | 2 (3.6) | |
Pulmonary artery pressure | 46.9 (14.1) | 45.9 (13.1) | 51.6 (17.7) | 0.073 |
Annulus area | 0.8 (0.2) | 0.8 (0.2) | 0.8 (0.3) | 0.968 |
Aortic sinus diameter | 3.2 (0.5) | 3.2 (0.5) | 3.3 (0.5) | 0.074 |
CT annulus diameter 1 | 25.1 (4.4) | 25 (4.3) | 25.2 (4.8) | 0.849 |
CT annulus diameter 2 | 24.2 (4.2) | 24.1 (4.2) | 24.8 (4.3) | 0.273 |
LV diastolic diameter | 4.7 (0.8) | 4.7 (0.8) | 4.8 (0.8) | 0.290 |
LVOT | 20.9 (1.9) | 20.8 (1.9) | 21.1 (1.9) | 0.354 |
The procedure characteristics shown in Table 3 demonstrated that 96.6% of the procedures where elective femoral access was used in 95.2% of the patients, 53.8% of the valve were balloon-expandable with no differences in the two cohorts. Although the PPM patients received a mildly larger mean valve size (27.3 mm vs 26.8 mm), this was not statistically significant (P = 0.266). The mean valve index was 129.4 and was not different in the two cohorts. However, a marginally significant higher procedure time of 1.6 h in the PPM cohort when compared to the no PPM cohort (1.4 h) (P = 0.056).
All | No PPM | PPM | P value | |
n = 357 | n = 300 | n = 57 | ||
Urgency | 0.699 | |||
Elective | 344 (96.6) | 288 (96.3) | 56 (98.2) | |
Emergency | 12 (3.4) | 11 (3.7) | 1 (1.8) | |
Valve | 0.471 | |||
Balloon expandable | 192 (53.8) | 164 (54.7) | 28 (49.1) | |
Self-expandable | 165 (46.2) | 136 (45.3) | 29 (50.9) | |
Valve size | 26.9 (3) | 26.8 (2.9) | 27.3 (3) | 0.266 |
Valve index | 129.4 (14.9) | 129.3 (15.1) | 129.9 (13.5) | 0.792 |
Valve sheath access site | 0.270 | |||
Right femoral | 241 (68.5) | 206 (69.8) | 35 (61.4) | |
Left femoral | 94 (26.7) | 72 (24.4) | 22 (38.6) | |
Right subclavian | 2 (0.6) | 2 (0.7) | 0 (0) | |
Left subclavian | 4 (1.1) | 4 (1.4) | 0 (0) | |
Right radial | 2 (0.6) | 2 (0.7) | 0 (0) | |
Transaortic | 9 (2.6) | 9 (3.1) | 0 (0) | |
Procedure time | 1.5 (0.8) | 1.4 (0.8) | 1.6 (0.9) | 0.056 |
Perioperative complications | ||||
Atrial fibrillation | 1 (0.3) | 1 (0.3) | 0 (0) | 1.00 |
Atrial flutter | 1 (0.3) | 1 (0.3) | 0 (0) | 1.00 |
AV block I | 6 (1.7) | 6 (2) | 0 (0) | 0.595 |
AV block II | 0 | 0 | 0 | - |
Complete AV block | 24 (6.7) | 1 (0.3) | 23 (40.4) | < 0.001 |
Ventricular tachycardia | 0 | 0 | 0 | - |
Ventricular fibrillation | 0 | 0 | 0 | - |
Bleeding | 8 (2.2) | 8 (2.7) | 0 (0) | 0.365 |
Stroke | 1 (0.3) | 1 (0.3) | 0 (0) | 1.00 |
Transfusion | 3 (0.8) | 3 (1) | 0 (0) | 1.00 |
Site bleeding | 0 | 0 | 0 | - |
Left axis deviation | 3 (0.8) | 2 (0.7) | 1 (1.8) | 0.408 |
LBBB | 0 | 0 | 0 | - |
RBBB | 0 | 0 | 0 | - |
Left anterior fascicular block | 0 | 0 | 0 | - |
Left posterior fascicular block | 0 | 0 | 0 | - |
MI | 1 (0.3) | 1 (0.3) | 0 (0) | 1.00 |
Other | 31 (8.7) | 24 (8) | 7 (12.3) | 0.305 |
There was no difference in perioperative complications of stroke (0.3%), atrial fibrillation/flutter (0.6%), bleeding (2.2%), and blood transfusion (0.3%) between the two cohorts. Also, although we observed no difference in the occurrence of type I AV block, perioperative complete heart block occurred at a significantly higher rate in the PPM cohort (40.4%), in comparison with no PPM cohort (0.3%); P < 0.001.
The study found that 57 out of 357 patients (16%) required PPM placement within one year following TAVR. The median time to implantation was two days. One-fourth of the patients received PPM within one day following TAVR, half received it within two days following TAVR, and three-quarters received it within nine days post-TAVR. A dual-chamber pacemaker was implanted in 56.2% of patients, a single-chamber in 24.6%, and a biventricular pacemaker type were placed in 8.8% of patients. Complete AV block was the predominant indication for PPM placement (66.7%), followed by CHF with LV dysfunction (10.5%), symptomatic bradycardia (8.8%), and symptomatic second-degree AV block (1.8%).
As presented in Table 4, the incidence of PPM was significantly higher in patients with baseline RBBB (35% vs 13%, P < 0.001), prolonged QRS ≥ 120 (30% vs 11%, P < 0.001), and prolonged QTc (29% vs 12%, P < 0.001) in comparison with the no PPM cohort. Further analysis showed that when compared to patients with normal QRS interval (< 100), patients with QRS > 100 ms interval had a higher PPM incidence for every 20ms above the normal QRS interval (Table 5). Also, the occurrence of preoperative supraventricular arrhythmia (A. fib, a flutter, junctional rhythm), was associated with a higher incidence of PPM when compared to sinus rhythm with marginal significance (22.8% vs 13.6%; P = 0.055).
Variable | Group | n | Incidence (%) | P value |
Age | < 65 yr | 10 | 0 (0) | 0.284 |
65-85 yr | 235 | 41 (17.4) | ||
> 85 yr | 112 | 16 (14.3) | ||
Sex | Male | 169 | 27 (16.0) | 1.00 |
Female | 188 | 30 (16.0) | ||
Pre-operative risk | Low | 37 | 3 (8.1) | 0.168 |
Intermediate | 84 | 12 (14.3) | ||
High | 235 | 41 (17.4) | ||
Valve type | Balloon expanding | 192 | 28 (14.6) | 0.471 |
Self-expanding | 165 | 29 (17.6) | ||
Prior BAV | Yes | 184 | 35 (19.0) | 0.116 |
No | 170 | 21 (12.4) | ||
Procedure time | < 1.5 h | 160 | 20 (12.5) | 0.071 |
≥ 1.5 h | 160 | 33 (20.6) | ||
Pre-op EKG rhythm abnormalities | Sinus | 265 | 36 (13.6) | 0.054 |
Atrial fibrillation | 83 | 18 (21.4) | ||
Atrial flutter | 4 | 2 (50.0) | ||
Junctional rhythm | 2 | 1 (50.0) | ||
Other | 2 | 0 (0) | ||
RBBB | Yes | 51 | 18 (35.3) | < 0.001 |
No | 306 | 39 (12.7) | ||
LBBB | Yes | 29 | 5 (17.2) | 0.794 |
No | 328 | 52 (15.9) | ||
AV block I | Yes | 55 | 9 (16.4) | 1.000 |
No | 302 | 48 (15.9) | ||
Bifascicular block | Yes | 5 | 0 (0) | 1.000 |
No | 352 | 57 (16.2) | ||
Left anterior fascicular block | Yes | 16 | 4 (25.0) | 0.299 |
No | 341 | 53 (15.5) | ||
Left posterior fascicular block | Yes | 1 | 1 (100) | 0.160 |
No | 356 | 56 (15.7) | ||
QRS interval | Abnormal (≥ 120 ms) | 89 | 27 (30.3) | < 0.001 |
Normal | 267 | 30 (11.2) | ||
QTc interval | Prolonged (≥ 470 ms) | 97 | 27 (27.8) | < 0.001 |
Normal | 259 | 30 (11.6) |
Variable | Group | n | Incidence | P value |
QRS interval | ≤ 100 | 194 | 17 (8.8) | < 0.001 |
101-120 | 74 | 14 (18.9) | ||
121-140 | 38 | 9 (23.7) | ||
141-160 | 40 | 16 (40.0) | ||
161-180 | 10 | 1 (10.0) | ||
Pre-op EKG supraventricular arrhythmia | Supraventricular arrhythmia1 | 91 | 21 (22.8) | 0.05 |
Sinus rhythm | 265 | 36 (13.6) |
Although the self-expanding valve (SEV) had a higher pacemaker incidence of 17.6% compared to the balloon-expandable valve (14.6%), this did not achieve statistical significance (P = 0.471). A higher procedure time of 1.5 h or more had a marginally significant higher PPM incidence of 20.6% compared to the procedure time of < 1.5 h (P = 0.071). There was also no significant association between age, sex, preoperative risk, or prior BV and a higher incidence of PPM placement in our cohort.
Positive predictors of PPM implantation in the cohort after multivariate analysis is shown in Table 6. As shown in Table 6, age, sex, prior AV replacement, self-expandable valve, valve index, operative risk, and aortic valve area were not significantly predictive of PPM Placement in our cohort. The odds of PPM implantation in patients with prior RBBB was 3.73 times that in patients without prior RBBB (95%CI: 1.92-7.26; P < 0.001). QRS interval ≥ 120 ms has 3.45 odds of PPM implantation (95%CI: 1.91-6.23, P < 0.001) compared to patients with normal QRS intervals. Although we observed that compared to patients with normal QTc interval, those with prolonged QTC interval had a 2.94 OR of PPM placement (95%CI: 1.64-5.28, P < 0.001); due to collinearity between QRS and QTc intervals, after stratification by abnormal QRS interval, there was no significant association between QTc intervals and PPM implantation. Further analysis showed an incremental impact of baseline prolonged QRS duration with reference to the normal value of < 100 ms. There was a consistently significant increase in the OR for every 20 ms increase in the QRS duration above 100 ms as shown in Figure 2.
OR | 95%CI | P value | |
Age (per 5 yr) | 0.95 | 0.8-1.12 | 0.549 |
Male | 1.00 | 0.57-1.76 | 0.996 |
Prior AV replacement | 0.21 | 0.03-1.55 | 0.125 |
CAD | 1.31 | 0.53-3.25 | 0.563 |
HF | 1.29 | 0.37-4.48 | 0.693 |
Self-expanding (Reference: balloon) | 1.25 | 0.71-2.20 | 0.442 |
Prior conduction defect-RBBB | 3.73 | 1.92-7.26 | < 0.001 |
Prior conduction defect-LBBB | 1.11 | 0.40-3.03 | 0.845 |
Prior conduction defect-LFAB | 1.81 | 0.56-5.83 | 0.319 |
Valve index | 1.00 | 0.98-1.02 | 0.806 |
Abnormal QRS (≥ 120 ms) | 3.45 | 1.91-6.23 | < 0.001 |
Prolonged QTc (≥ 470 ms) | 2.94 | 1.64-5.28 | < 0.001 |
Aortic valve area > 0.75 | 1.31 | 0.73-2.36 | 0.364 |
High preoperative risk (Reference: Low) | 2.40 | 0.70-8.17 | 0.163 |
Intermediate preoperative risk (Reference: Low) | 1.89 | 0.50-7.14 | 0.348 |
Supraventricular Arrhythmia on pre-op EKG (Reference: Sinus) | 1.88 | 1.03-3.43 | 0.039 |
After further multivariate analysis and adjusting the OR using a logistic regression model of PPM implantation regressed on baseline differences, diabetes, prior RBBB, QRS interval, and preoperative supraventricular arrhythmias, baseline type 2 DM, and abnormal QRS (≥ 120 ms), remained a significant predictor of PPM implantation (aOR: 2.16; CI: 1.18-3.94; P = 0.012), (aOR: 2.18; CI: 1.02-4.66; P = 0.045) respectively (Table 7). Baseline supraventricular arrhythmia had marginally significantly higher odds of PPM implantation when compared to sinus rhythm after multivariate-adjusted analysis (aOR: 1.82; CI: 0.97-3.42; P = 0.062) (Table 7).
aOR | 95%CI | P value | |
Diabetes | 2.16 | 1.18-3.94 | 0.012 |
Prior RBBB | 2.15 | 0.91-5.09 | 0.081 |
Abnormal QRS (≥ 120 ms) | 2.18 | 1.02-4.66 | 0.045 |
Supraventricular arrhythmia on pre-op EKG (Reference: Sinus rhythm) | 1.82 | 0.97-3.42 | 0.062 |
All the patients we have followed up for one year from TAVR or until death using MCHS electronic medical records. For deceased patients, we obtained the primary and secondary causes of death from the hospital records. For those not available within the MCHS, a death certificate was obtained from the state vital statistics record office. Compared to those without a PPM placement, patients with a PPM placement had a significantly longer median length of hospital stay (5 d vs 2 d; P < 0.001).
Clinical outcomes of any hospitalization, HF hospitalization, nonfatal MI, stroke, and mortality are presented in Figure 3. There was no difference in the clinical outcomes within 30 d. However, at one year, patients with PPM placement had a significantly higher incidence of hospitalization for HF (28% vs 14% P = 0.022) and nonfatal MI (9% vs 2%; P = 0.031). There was no significant difference in the incidence of stroke or all-cause mortality, as in Figure 3. Multivariate adjustments adjusted OR for the clinical outcome at one year revealed that compared to the no PPM cohort, the PPM implantation cohorts had a higher adjusted OR of HF hospitalization (aOR: 2.2; CI: 1.1-4.3; P = 0.022), and nonfatal MI (aOR: 3.9; CI: 1.1-14; P = 0.031) without any difference in mortality (aOR: 1.1; CI: 0.5-2.7; P = 0.796) at one year.
Our study found that 16% of the patients required PPM placement within one year following TAVR with a median time to implantation of 2 days and 75% of the patients receiving the pacemakers within nine days. The balloon-expandable ESV was used in 54% of the procedures, which resulted in a PPM implantation rate of 14.6%. In comparison, the auto-expanding MCRS was implanted in 46%, resulting in a 17.6% PPM implantation rate (P = 0.471). This PPM implantation rate was roughly at the median rate observed in a recent systematic review involving 17139 patients that showed a PPM implantation rate between 2.3% and 36.1%[35]. Also, in this study, MCRS resulted in higher PPM implantation rates (16.3%-37.7%), whereas ESV valves resulted in a lower pacemaker rate (4%-24%), which was also comparable to our study[35]. Similarly, Ullah et al[6], in a recent large-scale meta-analysis involving 31261 patients with a mean age of 81± 8 years, similar to our population, reported a mean PPM rate of 19.8% and a net rate ranging from 0.16% to 51.1%[6].
Fadahunsi et al[8], in the recent retrospective analysis of 9785 patients from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy registry, reported a median time of 3 d (IQR: 1 d-6 d) from TAVR to PPM implantation which also correlated with our study[8].
The most common indications for post-TAVR PPM implantation reported in several studies are high-grade AV block, new-onset or worsening LBBB, symptomatic bradycardia, unstable nodal conduction, and progressively worsening first-degree AV block with LBBB[16,36,37]. Similarly, in our study, complete AV block was the predominant indication for PPM placement (66.7%), followed by CHF with LV dysfunction (10.5%), symptomatic bradycardia (8.8%), and symptomatic second-degree AV block (1.8%).
Unlike most other studies, our study went further to evaluate the rate of pacemaker dependency following pacemaker interrogation at 1 mo and found that 78.9% of PPM patients were found to be pacemaker dependent one month after TAVR. This finding is supported by a previous observation that about half of the patients developing conduction abnormalities after TAVR improve over time without PPM implantation due to the resolution of reversible procedural per-aortic edema and inflammation caused during the procedure[16,38]. Although the exact proportion of patients and timing of resolution of this conduction abnormality remains unclear, from our study, it can be inferred that one-fifth of post-TAVR PPM patients may not be dependent on their pacemakers by one month, possibly due to the resolution of their transient abnormalities.
As presented in Table 3, the incidence of PPM was significantly higher in patients with RBBB (35% vs 13%, P < 0.001), prolonged QRS ≥ 120 without left or right bundle branch morphology, (30% vs 11%, P < 0.001), and prolonged QTc (29% vs 12%, P < 0.001). Further analysis showed that when compared to patients with normal QRS interval (≤ 100), patients with prolonged QRS interval had a higher PPM incidence for every 20 ms above the normal QRS interval (Figure 2).
Several studies have reported demographic, clinical, anatomic, EKG, and valve-related risk factors for conduction abnormalities requiring pacemakers after TAVR[6,8,12,16,19,20,37,38]. Siontis et al[18] from the systematic review and meta-analysis, reported that male sex, baseline first-degree AV block, RBBB, LBBB, left anterior hemiblock, intraprocedural AV block was associated with a high incidence of PPM placement post-TAVR[18]. Several other similar multiple-center studies, systematic reviews, and meta-analyses have shown similar risk factors for post-TAVR pacemaker requirements. However, none to our knowledge investigated the impact of nonspecific interventricular conduction defect on post-TAVR pacemaker requirement (defined in the study as QRS > 120 without LBBB and RBBB), which we found to be predictive of PPM placement[6,8,12,16,19,20,37,38].
Due to the potential correlation between RBBB, LBBB, and QRS duration, we evaluated PPM incidence by prolonged QRS stratified by prior conduction abnormalities and found that patients without prior RBBB or LBBB but had QRS ≥ 120 ms had a higher PPM incidence compared to those with QRS interval < 120 ms (23% vs 11%; P = 0.05). Also, stratifying PPM incidence by baseline prolonged QTc interval [> 470 ms], abnormal QRS canceled the effect of QTC on PPM requirement due to collinearity between the QRS duration and QTc interval. Further multivariate analysis revealed a consistently significant increase in the OR of the PPM requirement for every 20 ms increase in the QRS duration above 100 ms, as shown in Figure 2. Overall, in patients with QRS > 120 ms, our study was found to have an adjusted OR of 2.18 (95%CI: 1.02-4.66, P = 0.045) for post-TAVR PPM placement.
Another interesting finding in our study is that baseline type 2 DM was a significant predictor of PPM placement with an adjusted OR of 2.16 [95%CI; 1.18-3.94, P = 0.012], a finding that was scarcely reported in several studies. Notably, Sammour et al[16], in a recent systematic review, reported that type 2 DM was a pre-procedural predictor of new-onset LBBB, which is a known indication for PPM requirement. This further supports the findings of our study[16].
Among the traditional risk factors for PPM implantation, our study found that the odds of pacemaker placement in patients with prior RBBB was 3.73 (95%CI: 1.92-7.26; P < 0.001) times those without prior RBBB in the unadjusted model which tended towards significance following multivariate analysis (aOR: 2.15; 95%CI: 0.91-5.09; P = 0.081). Contrary to the widely reported increased PPM implantation risk inherent with the use of SEV[8,6,16], our study did not demonstrate a significantly higher risk of PPM placement with the SEV when compared to the balloon-expandable ESV (OR: 1.25; CI: 0.71-2.20; P = 0.4.42). This finding can be explained by the fact that our institution started implanting self-expandable valves in 2015, three years after they started the balloon-expandable valve; this delay presumably helps the TAVR operators advance in the learning curve and gain considerable experience with the TAVR procedure[39]. Also, over the last few years, there have been manufacturer-assisted modifications of self-expandable valve implantation techniques in our health system, which emphasize shallow valve implantation depth and cusp overlap in order to avoid the anatomical vicinity of the conduction tissues during TAVR procedures. This performance improvement process, which resulted in lower SEV-related PPM implantation, was informed by contemporary studies that demonstrated that implantation depth relative to membranous septum length is an independent risk factor for post-TAVR PPM implantation[12,40].
An essential clinical significance of the findings of our study is its ability to enhance clinical decision-making prior to TAVR procedures, assist in patients’ overall PPM risk evaluation, and choice of valve system to implant. A notable risk prediction score that can be refined by our findings of increased PPM risk for QRS > 100 ms is the Emory risk score for the prediction of PPM requirement following TAVR developed by Kiani et al[41]. This scoring system incorporates the history of RBBB (2 points), QRS interval ≥ 140 ms (one-point), syncope (one-point), valve oversizing ≥ 16% (1 point) and has an OR of 2.2 per every point increase (P < 0.001)[41]. Adjusting the QRS duration cut-off may increase the sensitivity of this scoring system. However, given the relatively small size of our cohort, further, more extensive studies will be needed to validate this finding.
Although PPM implantation in the non-TAVR population has been associated with complications like device infection, pocket erosion or hematoma, lead failure, right ventricular perforation, and lead-induced tricuspid regurgitation which might lead to higher mortality[42,43], studies on clinical outcomes in TAVR patients with pacemaker have shown conflicting results with the majority of studies showing no mortality impact of PPM implantation at 1 year[6,16].
At 30 d post TAVR, our study showed no significant increase in clinical outcomes of all-cause mortality, hospitalization for HF, nonfatal MI, and stroke. However, at 1 year post-TAVR, relative to the no PPM cohort, the PPM patients had a significantly higher incidence of hospitalization for HF (28% vs 14% P = 0.022), and nonfatal MI (9% vs 2%; P = 0.031) with no mortality difference Figure 3. Further evaluation of one-year survival using a Kaplan-Meier curve showed no survival difference between the two cohorts (Figure 4). This lack of impact of PPM implantation all-cause mortality or survival was also echoed by several multiple studies[44-51].
Similar to our finding of higher odds of HF hospitalization (aOR: 3.9; CI: 1.1-14; P = 0.031), López-Aguilera et al[52] in a single-center prospective study, and Chamandi et al[53] in the multicenter retrospective study both showed an increased risk of hospitalization due to HF in post-TAVR PPM patients[52,53].
This study is a single-center retrospective analysis of our experience as a tertiary cardiology referral health center in the Midwestern United States. Our findings may not reflect the experience in other regions. Also, there was no randomization of the valves to patients based on established criteria but based on the decision of the multidisciplinary TAVR team. As a result, the distribution of valves, patient selection, and valve sizes in each cohort might have been affected. However, the observed relatively equal distribution of these and other patient-related variables between each cohort suggests that this factor might not have significantly contributed to our study findings.
Patients with baseline type 2 DM and QRS duration > 100 ms, regardless of the presence of right or left bundle branch morhology, are at increased risk of permanent pacemaker implantation post-TAVR. A linear association may exist between post-TAVR PPM incidence and every 20 ms prolongation in QRS duration > 100 ms. Patients with PPM implantation may have higher risks of HF hospitalization and non-fatal MI at 1 year post TAVR. In light of the expanded indication of TAVR and the clinical and economic impact of PPM implantation, multidisciplinary heart teams should meticulously risk-stratify pre-TAVR patients regarding PPM requirements using this new evidence.
Conduction abnormalities requiring permanent pacemakers (PPM) are short-term complications following transcatheter aortic valve replacement (TAVR), and their clinical outcomes remain conflicting. Potential novel predictors of post-TAVR PPM, like QRS duration, QTc prolongation, and supraventricular arrhythmias, have been poorly studied.
The evaluation of novel predictors of PPM placement post TAVR light nonspecific interventricular conduction defect, will enhance clinical decision making prior to the TAVR procedure, assist in patient pacemaker risk evaluation, and further refine the indications of pacemaker placement.
To determine the timing, incidence and novel predictors of PPM implantation post TAVR. To evaluate and compare clinical outcomes of length of hospitalization, heart failure (HF) hospitalization, myocardial infarction (MI) and cardiovascular death post TAVR between patients requiring permanent pacemaker implantation and others without pacemaker at 1 year post TAVR procedure.
A retrospective cohort study that identified patients with TAVR between January 1, 2012 to December 31, 2019. The cohort was divides into those with post-TAVR PPM and those without PPM. Both groups were followed for one year.
Of 357 patients that met inclusion criteria, the mean age was 80 years, 188 (52.7%) were male, and 57 (16%) had a PPM implantation. Baseline demographics, valve type, and cardiovascular risk factors were similar except for type II diabetes mellitus (DM), which was more prevalent in the PPM cohort (59.6% vs 40.7%; P = 0.009). The PPM cohort had a significantly higher rate of pre-procedure right bundle branch block, prolonged QRS > 120 ms, prolonged QTc > 470 ms, and supraventricular arrhythmias. There was a consistently significant increase in the odds ratio (OR) of PPM implantation for every 20 ms increase in the QRS duration above 100 ms: QRS 101-120 (OR: 2.44; CI: 1.14-5.25; P = 0.022), QRS 121-140 (OR: 3.25; CI: 1.32-7.98; P = 0.010), QRS 141-160 (OR: 6.98; CI: 3.10-15.61; P < 0.001). After model adjustment for baseline risk factors, the OR remained significant for type II DM and QRS > 120. The PPM cohort had a higher OR of HF hospitalization and nonfatal MI without any difference in mortality (aOR: 1.1; CI: 0.5-2.7; P = 0.796) at one year.
Pre-TAVR type II DM and QRS duration > 120, regardless of the presence of bundle branch blocks, are predictors of post-TAVR PPM. Post-TAVR, patients with PPM implantation may have higher odds of HF hospitalization and non-fatal MI at 1 year.
In light of the expanded indication of TAVR to involve lower risk patients and the clinical impact of PPM implantation, risk assessment using the predictors outlined in the study will help optimize pre-procedural risk stratification. Further larger multicenter studies will be needed to further investigate the impact of this number predictors and post-TAVR pacemaker requirement.
Provenance and peer review: Unsolicited article; Externally peer reviewed.
Peer-review model: Single blind
Corresponding Author's Membership in Professional Societies: American Heart Association, No. 298575465.
Specialty type: Cardiac and cardiovascular systems
Country/Territory of origin: United States
Peer-review report’s scientific quality classification
Grade A (Excellent): A
Grade B (Very good): B
Grade C (Good): 0
Grade D (Fair): 0
Grade E (Poor): 0
P-Reviewer: El-Serafy AS, Egypt; Sharma D, India S-Editor: Fan JR L-Editor: A P-Editor: Yuan YY
1. | Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S; PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363:1597-1607. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 5086] [Cited by in F6Publishing: 5318] [Article Influence: 379.9] [Reference Citation Analysis (1)] |
2. | Writing Committee Members; Otto CM, Nishimura RA, Bonow RO, Carabello BA, Erwin JP 3rd, Gentile F, Jneid H, Krieger EV, Mack M, McLeod C, O'Gara PT, Rigolin VH, Sundt TM 3rd, Thompson A, Toly C. 2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. J Am Coll Cardiol. 2021;77:e25-e197. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 969] [Cited by in F6Publishing: 885] [Article Influence: 295.0] [Reference Citation Analysis (0)] |
3. | Mack MJ, Leon MB, Thourani VH, Makkar R, Kodali SK, Russo M, Kapadia SR, Malaisrie SC, Cohen DJ, Pibarot P, Leipsic J, Hahn RT, Blanke P, Williams MR, McCabe JM, Brown DL, Babaliaros V, Goldman S, Szeto WY, Genereux P, Pershad A, Pocock SJ, Alu MC, Webb JG, Smith CR; PARTNER 3 Investigators. Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med. 2019;380:1695-1705. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 2562] [Cited by in F6Publishing: 3215] [Article Influence: 643.0] [Reference Citation Analysis (0)] |
4. | Andersen HR. How Transcatheter Aortic Valve Implantation (TAVI) Was Born: The Struggle for a New Invention. Front Cardiovasc Med. 2021;8:722693. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 7] [Cited by in F6Publishing: 3] [Article Influence: 1.0] [Reference Citation Analysis (0)] |
5. | Reardon MJ, Van Mieghem NM, Popma JJ, Kleiman NS, Søndergaard L, Mumtaz M, Adams DH, Deeb GM, Maini B, Gada H, Chetcuti S, Gleason T, Heiser J, Lange R, Merhi W, Oh JK, Olsen PS, Piazza N, Williams M, Windecker S, Yakubov SJ, Grube E, Makkar R, Lee JS, Conte J, Vang E, Nguyen H, Chang Y, Mugglin AS, Serruys PW, Kappetein AP; SURTAVI Investigators. Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med. 2017;376:1321-1331. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 1824] [Cited by in F6Publishing: 2058] [Article Influence: 294.0] [Reference Citation Analysis (0)] |
6. | Ullah W, Zahid S, Zaidi SR, Sarvepalli D, Haq S, Roomi S, Mukhtar M, Khan MA, Gowda SN, Ruggiero N, Vishnevsky A, Fischman DL. Predictors of Permanent Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement - A Systematic Review and Meta-Analysis. J Am Heart Assoc. 2021;10:e020906. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 11] [Cited by in F6Publishing: 29] [Article Influence: 9.7] [Reference Citation Analysis (0)] |
7. | Bouma BJ, van Den Brink RB, van Der Meulen JH, Verheul HA, Cheriex EC, Hamer HP, Dekker E, Lie KI, Tijssen JG. To operate or not on elderly patients with aortic stenosis: the decision and its consequences. Heart. 1999;82:143-148. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 218] [Cited by in F6Publishing: 205] [Article Influence: 8.2] [Reference Citation Analysis (0)] |
8. | Fadahunsi OO, Olowoyeye A, Ukaigwe A, Li Z, Vora AN, Vemulapalli S, Elgin E, Donato A. Incidence, Predictors, and Outcomes of Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement: Analysis From the U.S. Society of Thoracic Surgeons/American College of Cardiology TVT Registry. JACC Cardiovasc Interv. 2016;9:2189-2199. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 203] [Cited by in F6Publishing: 188] [Article Influence: 23.5] [Reference Citation Analysis (0)] |
9. | Makki N, Dollery J, Jones D, Crestanello J, Lilly S. Conduction disturbances after TAVR: Electrophysiological studies and pacemaker dependency. Cardiovasc Revasc Med. 2017;18:S10-S13. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 20] [Cited by in F6Publishing: 23] [Article Influence: 3.3] [Reference Citation Analysis (0)] |
10. | Roten L, Stortecky S, Scarcia F, Kadner A, Tanner H, Delacrétaz E, Meier B, Windecker S, Carrel T, Wenaweser P. Atrioventricular conduction after transcatheter aortic valve implantation and surgical aortic valve replacement. J Cardiovasc Electrophysiol. 2012;23:1115-1122. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 33] [Cited by in F6Publishing: 39] [Article Influence: 3.3] [Reference Citation Analysis (0)] |
11. | Bagur R, Rodés-Cabau J, Gurvitch R, Dumont É, Velianou JL, Manazzoni J, Toggweiler S, Cheung A, Ye J, Natarajan MK, Bainey KR, DeLarochellière R, Doyle D, Pibarot P, Voisine P, Côté M, Philippon F, Webb JG. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings. JACC Cardiovasc Interv. 2012;5:540-551. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 119] [Cited by in F6Publishing: 128] [Article Influence: 10.7] [Reference Citation Analysis (0)] |
12. | Na J, Nixon B, Childress J, Han P, Norcross G, Liskov S, Jeudy J, Jimenez Restrepo A. Anatomical characteristics of the membranous septum are predictive of pacemaker requirement in patients undergoing transcatheter aortic valve replacement. J Interv Card Electrophysiol. 2022;63:449-459. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 1] [Cited by in F6Publishing: 1] [Article Influence: 0.3] [Reference Citation Analysis (0)] |
13. | Netter FH. Atlas of human anatomy. Philadelphia, PA: Saunders/Elsevier.Plate 219, 2006. [Cited in This Article: ] |
14. | MacDonald I, Pasupati S. Transcatheter aortic valve implantation: know the differences between the currently available technologies. Eur Heart J. 2010;31:1663-1665. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 1] [Cited by in F6Publishing: 2] [Article Influence: 0.2] [Reference Citation Analysis (0)] |
15. | Rubín JM, Avanzas P, del Valle R, Renilla A, Ríos E, Calvo D, Lozano I, Anguera I, Díaz-Molina B, Cequier A, Morís de la Tassa C. Atrioventricular conduction disturbance characterization in transcatheter aortic valve implantation with the CoreValve prosthesis. Circ Cardiovasc Interv. 2011;4:280-286. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 66] [Cited by in F6Publishing: 74] [Article Influence: 5.7] [Reference Citation Analysis (0)] |
16. | Sammour Y, Krishnaswamy A, Kumar A, Puri R, Tarakji KG, Bazarbashi N, Harb S, Griffin B, Svensson L, Wazni O, Kapadia SR. Incidence, Predictors, and Implications of Permanent Pacemaker Requirement After Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv. 2021;14:115-134. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 42] [Cited by in F6Publishing: 122] [Article Influence: 40.7] [Reference Citation Analysis (4)] |
17. | Piazza N, Onuma Y, Jesserun E, Kint PP, Maugenest AM, Anderson RH, de Jaegere PP, Serruys PW. Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve. JACC Cardiovasc Interv. 2008;1:310-316. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 270] [Cited by in F6Publishing: 282] [Article Influence: 18.8] [Reference Citation Analysis (0)] |
18. | Siontis GC, Jüni P, Pilgrim T, Stortecky S, Büllesfeld L, Meier B, Wenaweser P, Windecker S. Predictors of permanent pacemaker implantation in patients with severe aortic stenosis undergoing TAVR: a meta-analysis. J Am Coll Cardiol. 2014;64:129-140. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 413] [Cited by in F6Publishing: 371] [Article Influence: 37.1] [Reference Citation Analysis (0)] |
19. | Gulati R, Wang A. Left Bundle Branch Block Before Transcatheter Aortic Valve Replacement. Circ Cardiovasc Interv. 2018;11:e007361. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 3] [Cited by in F6Publishing: 4] [Article Influence: 0.7] [Reference Citation Analysis (0)] |
20. | Nazif TM, Dizon JM, Hahn RT, Xu K, Babaliaros V, Douglas PS, El-Chami MF, Herrmann HC, Mack M, Makkar RR, Miller DC, Pichard A, Tuzcu EM, Szeto WY, Webb JG, Moses JW, Smith CR, Williams MR, Leon MB, Kodali SK; PARTNER Publications Office. Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve replacement: the PARTNER (Placement of AoRtic TraNscathetER Valves) trial and registry. JACC Cardiovasc Interv. 2015;8:60-69. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 353] [Cited by in F6Publishing: 388] [Article Influence: 43.1] [Reference Citation Analysis (0)] |
21. | Urena M, Webb JG, Tamburino C, Muñoz-García AJ, Cheema A, Dager AE, Serra V, Amat-Santos IJ, Barbanti M, Immè S, Briales JH, Benitez LM, Al Lawati H, Cucalon AM, García Del Blanco B, López J, Dumont E, Delarochellière R, Ribeiro HB, Nombela-Franco L, Philippon F, Rodés-Cabau J. Permanent pacemaker implantation after transcatheter aortic valve implantation: impact on late clinical outcomes and left ventricular function. Circulation. 2014;129:1233-1243. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 209] [Cited by in F6Publishing: 244] [Article Influence: 22.2] [Reference Citation Analysis (0)] |
22. | Curtis AB, Worley SJ, Adamson PB, Chung ES, Niazi I, Sherfesee L, Shinn T, Sutton MS; Biventricular versus Right Ventricular Pacing in Heart Failure Patients with Atrioventricular Block (BLOCK HF) Trial Investigators. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med. 2013;368:1585-1593. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 520] [Cited by in F6Publishing: 561] [Article Influence: 51.0] [Reference Citation Analysis (0)] |
23. | Steinberg JS, Fischer A, Wang P, Schuger C, Daubert J, McNitt S, Andrews M, Brown M, Hall WJ, Zareba W, Moss AJ; MADIT II Investigators. The clinical implications of cumulative right ventricular pacing in the multicenter automatic defibrillator trial II. J Cardiovasc Electrophysiol. 2005;16:359-365. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 258] [Cited by in F6Publishing: 236] [Article Influence: 12.4] [Reference Citation Analysis (0)] |
24. | Sweeney MO, Hellkamp AS, Ellenbogen KA, Greenspon AJ, Freedman RA, Lee KL, Lamas GA; MOde Selection Trial Investigators. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation. 2003;107:2932-2937. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 1195] [Cited by in F6Publishing: 1171] [Article Influence: 55.8] [Reference Citation Analysis (0)] |
25. | Bavaria JE, Tommaso CL, Brindis RG, Carroll JD, Deeb GM, Feldman TE, Gleason TG, Horlick EM, Kavinsky CJ, Kumbhani DJ, Miller DC, Seals AA, Shahian DM, Shemin RJ, Sundt TM 3rd, Thourani VH. 2018 AATS/ACC/SCAI/STS Expert Consensus Systems of Care Document: Operator and Institutional Recommendations and Requirements for Transcatheter Aortic Valve Replacement: A Joint Report of the American Association for Thoracic Surgery, American College of Cardiology, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. J Am Coll Cardiol. 2019;73:340-374. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 72] [Cited by in F6Publishing: 65] [Article Influence: 13.0] [Reference Citation Analysis (0)] |
26. | STS online cardiac surgery risk calculator. [cited April 5, 2015]. Available from: http://209.220.160.181/STSWebRiskCalc261/de.aspx. [Cited in This Article: ] |
27. | Magalhaes MA, Minha S, Rodriguez-Weisson JF, Escarcega RO, Baker NC, Okubagzi P, Torguson R. Usefulness of a novel index in predicting permanent pacemaker necessity following transcatheter aortic valve replacement. JACC Cardiovasc Interv. 2014;7(2_S):S4-S4. [Cited in This Article: ] |
28. | Maan A, Refaat MM, Heist EK, Passeri J, Inglessis I, Ptaszek L, Vlahakes G, Ruskin JN, Palacios I, Sundt T, Mansour M. Incidence and Predictors of Pacemaker Implantation in Patients Undergoing Transcatheter Aortic Valve Replacement. Pacing Clin Electrophysiol. 2015;38:878-886. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 36] [Cited by in F6Publishing: 39] [Article Influence: 4.3] [Reference Citation Analysis (0)] |
29. | Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodés-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB; Valve Academic Research Consortium-2. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. J Thorac Cardiovasc Surg. 2013;145:6-23. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 644] [Cited by in F6Publishing: 716] [Article Influence: 59.7] [Reference Citation Analysis (0)] |
30. | Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodés-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB; Valve Academic Research Consortium (VARC)-2. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2). Eur J Cardiothorac Surg. 2012;42:S45-S60. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 578] [Cited by in F6Publishing: 626] [Article Influence: 52.2] [Reference Citation Analysis (0)] |
31. | Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, Krucoff MW, Mack M, Mehran R, Miller C, Morel MA, Petersen J, Popma JJ, Takkenberg JJ, Vahanian A, van Es GA, Vranckx P, Webb JG, Windecker S, Serruys PW. Standardized endpoint definitions for Transcatheter Aortic Valve Implantation clinical trials: a consensus report from the Valve Academic Research Consortium. J Am Coll Cardiol. 2011;57:253-269. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 636] [Cited by in F6Publishing: 666] [Article Influence: 51.2] [Reference Citation Analysis (0)] |
32. | Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodés-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur Heart J. 2012;33:2403-2418. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 736] [Cited by in F6Publishing: 843] [Article Influence: 76.6] [Reference Citation Analysis (0)] |
33. | Kappetein AP, Head SJ, Généreux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodés-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB; Valve Academic Research Consortium-2. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. EuroIntervention. 2012;8:782-795. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 144] [Cited by in F6Publishing: 164] [Article Influence: 14.9] [Reference Citation Analysis (0)] |
34. | R Core Team (2019). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. [cited April 5, 2015]. Available from: https://www.R-project.org/. [Cited in This Article: ] |
35. | van Rosendael PJ, Delgado V, Bax JJ. Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review. Eur Heart J. 2018;39:2003-2013. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 150] [Cited by in F6Publishing: 163] [Article Influence: 27.2] [Reference Citation Analysis (0)] |
36. | Kapadia SR, Wazni O, Krishnaswamy A. Pacemaker Implantation After TAVR. JACC Cardiovasc Imaging. 2017;10:1148-1150. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 18] [Cited by in F6Publishing: 20] [Article Influence: 2.9] [Reference Citation Analysis (0)] |
37. | Massoullié G, Bordachar P, Ellenbogen KA, Souteyrand G, Jean F, Combaret N, Vorilhon C, Clerfond G, Farhat M, Ritter P, Citron B, Lusson JR, Motreff P, Ploux S, Eschalier R. New-Onset Left Bundle Branch Block Induced by Transcutaneous Aortic Valve Implantation. Am J Cardiol. 2016;117:867-873. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 29] [Cited by in F6Publishing: 38] [Article Influence: 4.8] [Reference Citation Analysis (0)] |
38. | Auffret V, Puri R, Urena M, Chamandi C, Rodriguez-Gabella T, Philippon F, Rodés-Cabau J. Conduction Disturbances After Transcatheter Aortic Valve Replacement: Current Status and Future Perspectives. Circulation. 2017;136:1049-1069. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 285] [Cited by in F6Publishing: 302] [Article Influence: 43.1] [Reference Citation Analysis (0)] |
39. | Umukoro PE, Yeung-Lai-Wah P, Pathak S, Elkhidir S, Soodi D, Delgoffe B, Berg R, Anderson KP, Garcia-Montilla RJ. Three-Year Survival after Transcatheter Aortic Valve Replacement: Findings from the Marshfield Aortic Valve Experience (MAVE) Study. Clin Med Res. 2021;19:10-18. [PubMed] [DOI] [Cited in This Article: ] [Reference Citation Analysis (0)] |
40. | Jilaihawi H, Zhao Z, Du R, Staniloae C, Saric M, Neuburger PJ, Querijero M, Vainrib A, Hisamoto K, Ibrahim H, Collins T, Clark E, Pushkar I, Bamira D, Benenstein R, Tariq A, Williams M. Minimizing Permanent Pacemaker Following Repositionable Self-Expanding Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv. 2019;12:1796-1807. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 130] [Cited by in F6Publishing: 113] [Article Influence: 22.6] [Reference Citation Analysis (0)] |
41. | Kiani S, Kamioka N, Black GB, Lu MLR, Lisko JC, Rao B, Mengistu A, Gleason PT, Stewart JP, Caughron H, Dong A, Patel H, Grubb KJ, Greenbaum AB, Devireddy CM, Guyton RA, Leshnower B, Merchant FM, El-Chami M, Westerman SB, Lloyd MS, Babaliaros VC, Hoskins MH. Development of a Risk Score to Predict New Pacemaker Implantation After Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv. 2019;12:2133-2142. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 42] [Cited by in F6Publishing: 45] [Article Influence: 9.0] [Reference Citation Analysis (0)] |
42. | Al-Bawardy R, Krishnaswamy A, Rajeswaran J, Bhargava M, Wazni O, Wilkoff B, Tuzcu EM, Martin D, Thomas J, Blackstone E, Kapadia S. Tricuspid regurgitation and implantable devices. Pacing Clin Electrophysiol. 2015;38:259-266. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 47] [Cited by in F6Publishing: 48] [Article Influence: 4.8] [Reference Citation Analysis (0)] |
43. | Palmisano P, Accogli M, Zaccaria M, Luzzi G, Nacci F, Anaclerio M, Favale S. Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in Italy. Europace. 2013;15:531-540. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 87] [Cited by in F6Publishing: 101] [Article Influence: 9.2] [Reference Citation Analysis (0)] |
44. | D'Ancona G, Pasic M, Unbehaun A, Hetzer R. Permanent pacemaker implantation after transapical transcatheter aortic valve implantation. Interact Cardiovasc Thorac Surg. 2011;13:373-376. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 37] [Cited by in F6Publishing: 40] [Article Influence: 3.1] [Reference Citation Analysis (0)] |
45. | Buellesfeld L, Stortecky S, Heg D, Hausen S, Mueller R, Wenaweser P, Pilgrim T, Gloekler S, Khattab AA, Huber C, Carrel T, Eberle B, Meier B, Boekstegers P, Jüni P, Gerckens U, Grube E, Windecker S. Impact of permanent pacemaker implantation on clinical outcome among patients undergoing transcatheter aortic valve implantation. J Am Coll Cardiol. 2012;60:493-501. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 168] [Cited by in F6Publishing: 178] [Article Influence: 14.8] [Reference Citation Analysis (0)] |
46. | De Carlo M, Giannini C, Bedogni F, Klugmann S, Brambilla N, De Marco F, Zucchelli G, Testa L, Oreglia J, Petronio AS. Safety of a conservative strategy of permanent pacemaker implantation after transcatheter aortic CoreValve implantation. Am Heart J. 2012;163:492-499. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 87] [Cited by in F6Publishing: 95] [Article Influence: 7.9] [Reference Citation Analysis (0)] |
47. | Van Mieghem NM, van der Boon RM, Nuis RJ, Schultz C, van Geuns RJ, Serruys PW, Kappetein AP, van Domburg RT, de Jaegere PP. Cause of death after transcatheter aortic valve implantation. Catheter Cardiovasc Interv. 2014;83:E277-E282. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 35] [Cited by in F6Publishing: 37] [Article Influence: 3.4] [Reference Citation Analysis (0)] |
48. | Gensas CS, Caixeta A, Siqueira D, Carvalho LA, Sarmento-Leite R, Mangione JA, Lemos PA, Colafranceschi AS, Caramori P, Ferreira MC, Abizaid A, Brito FS Jr; Brazilian Registry in Transcatheter Aortic Valve Implantation Investigators. Predictors of permanent pacemaker requirement after transcatheter aortic valve implantation: insights from a Brazilian registry. Int J Cardiol. 2014;175:248-252. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 33] [Cited by in F6Publishing: 36] [Article Influence: 3.6] [Reference Citation Analysis (0)] |
49. | Dizon JM, Nazif TM, Hess PL, Biviano A, Garan H, Douglas PS, Kapadia S, Babaliaros V, Herrmann HC, Szeto WY, Jilaihawi H, Fearon WF, Tuzcu EM, Pichard AD, Makkar R, Williams M, Hahn RT, Xu K, Smith CR, Leon MB, Kodali SK; PARTNER Publications Office. Chronic pacing and adverse outcomes after transcatheter aortic valve implantation. Heart. 2015;101:1665-1671. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 93] [Cited by in F6Publishing: 105] [Article Influence: 11.7] [Reference Citation Analysis (0)] |
50. | Kawaguchi AT, D'Allessandro C, Collet JP, Cluzel P, Makri R, Leprince P. Ventricular conduction defects after transcatheter aortic valve implantation: a single-institute analysis. Artif Organs. 2015;39:409-415. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 12] [Cited by in F6Publishing: 13] [Article Influence: 1.4] [Reference Citation Analysis (0)] |
51. | Giustino G, Van der Boon RM, Molina-Martin de Nicolas J, Dumonteil N, Chieffo A, de Jaegere PP, Tchetche D, Marcheix B, Millischer D, Cassagneau R, Carrié D, Van Mieghem NM, Colombo A. Impact of permanent pacemaker on mortality after transcatheter aortic valve implantation: the PRAGMATIC (Pooled Rotterdam-Milan-Toulouse in Collaboration) Pacemaker substudy. EuroIntervention. 2016;12:1185-1193. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 22] [Cited by in F6Publishing: 26] [Article Influence: 3.3] [Reference Citation Analysis (0)] |
52. | López-Aguilera J, Segura Saint-Gerons JM, Sánchez Fernández J, Mazuelos Bellido F, Pan Álvarez-Ossorio M, Suárez de Lezo J, Romero Moreno M, Ojeda Pineda S, Pavlovic D, Mesa Rubio D, Rodriguez Diego S, Ferreiro C, Durán E, Chavarría J, Moya González J. Long-term clinical impact of permanent cardiac pacing after transcatheter aortic valve implantation with the CoreValve prosthesis: a single center experience. Europace. 2018;20:993-1000. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 8] [Cited by in F6Publishing: 10] [Article Influence: 1.4] [Reference Citation Analysis (0)] |
53. | Chamandi C, Barbanti M, Munoz-Garcia A, Latib A, Nombela-Franco L, Gutiérrez-Ibanez E, Veiga-Fernandez G, Cheema AN, Cruz-Gonzalez I, Serra V, Tamburino C, Mangieri A, Colombo A, Jiménez-Quevedo P, Elizaga J, Laughlin G, Lee DH, Garcia Del Blanco B, Rodriguez-Gabella T, Marsal JR, Côté M, Philippon F, Rodés-Cabau J. Long-Term Outcomes in Patients With New Permanent Pacemaker Implantation Following Transcatheter Aortic Valve Replacement. JACC Cardiovasc Interv. 2018;11:301-310. [PubMed] [DOI] [Cited in This Article: ] [Cited by in Crossref: 98] [Cited by in F6Publishing: 85] [Article Influence: 14.2] [Reference Citation Analysis (0)] |