Figure 1
Extraction of an infected pacing system in a patient with congenitally corrected transposition of the great arteries, dextrocardia, and a left ventricle-to-pulmonary artery conduit using a mechanical rotational extraction tool.
Figure 2
Extraction of a chronically implanted leadless pacemaker (starred) because of poor parameters using a dedicated leadless pacemaker trilumen snare retrieval catheter passed through the small tricuspid annulus and multiple abandoned leads.
Figure 3 A reformatted computed tomography image showing the main atrial mass just under the Glen anastomosis (superior vena cava anastomosis to pulmonary artery), with a trajectory suggesting a suitable superior approach for puncture to facilitate leadless pace maker implantation, as illustrated by the arrow.
The patient had dextrocardia, left atrial isomerism, and an unbalanced atrioventricular septal defect palliated with a Kawashima procedure, resulting in single-ventricle physiology.
Figure 4
Normal trajectory of pacing leads in patients with transposition of the great arteries-atrial switch with the ventricular leads positioned towards the LV apex and free wall through the baffle tissue (starred) and the atrial lead to the left atrial roof (arrowed).
Figure 5 Left bundle area pacing in a patient with repaired transposition of the great arteries-atrial switch.
A: The ventricular lead has been deployed into the LV septum using a guide catheter and appears to come back on itself in the fluoro image; B: Comparison of native; C: Paced QRS is shown alongside.
Figure 6 A coronary sinus angiogram in a transposition of the great arteries-atrial switch patient with an existing dual chamber implantable defibrillator and superior vena cava baffle stent (arrowed).
Using a multi-purpose coronary sinus guide catheter, an angiogram (starred) demonstrates all the flow towards the left ventricle side with no clear early anterior branches or middle cardiac vein to aid placement of a lead to the systemic right ventricle.
Figure 7 Baffle puncture in the atrial switch.
A: Superior baffle puncture in a patient with transposition of the great arteries-atrial switch using a support sheath and radiofrequency needle (arrowed); B: Subsequent enlargement of the baffle puncture using a large non-compliant balloon to create lead access (arrowed).
Figure 8
An atrial leadless pacemaker is seen positioned toward the left atrial appendage of a patient with transposition of the great arteries-atrial switch following a successful extraction for pocket infection.
Figure 9 Types of Fontan operation.
A: The atrio-pulmonary Fontan- arrowed is the anastomosis of the right atrial appendage to pulmonary artery; B: The lateral tunnel Fontan, starred is the Glen shunt and arrowed is the atrial patch forming an intracardiac tunnel to divert blood to the pulmonary artery; C: The Extra-cardiac Fontan, with the Glen shunt starred and the conduit diverting all the IVC flow to the pulmonary artery is arrowed. Citation: Sathananthan G, Lowe BS, Hornung T. Editor’s Pick: The Fontan Circulation. EMJ Cardiol 2016; 4: 76-83. Copyright © European Medical Group LTD. Published by European Medical Group LTD. The article is open access (Supplementary material).
Figure 10 Using a conduction system pacing guide catheter, the right atrial appendage to pulmonary artery has been cannulated (starred) with a large amount of catheter within the dilated right atrium and a standard active pacing lead tip pushed down into the stump of the pulmonary valve/ outflow tract.
Threshold here was less than 1 mv at 0.4 ms.
Figure 11 Retrograde endocardial ventricular pacing in the Fontan.
A: Using a coronary sinus guide catheter (starred), the pulmonary artery has been cannulated from the Glen anastomosis and wired through the residual outflow tract stump into the ventricular mass to allow lead delivery; B: Final lead placement in the apical septum of the single ventricle (starred). Multiple abandoned epicardial leads can be seen in the background.
Figure 12 Fenestration dilatation in an extracardiac Fontan.
A: The fenestration has been wired from below and the ballooned to increase its size before pacing (arrowed); B: Using a deflectable conduction system pacing guide catheter, pacing leads are inserted via the larger fenestration (arrowed).
Figure 13 Leadless pacemaker insertion in an extracardiac Fontan.
A: Dilatation of the baffle tract with a noncompliant balloon, with a waist seen at the puncture point (arrowed); B: Careful advancement of the sheath into the pulmonary venous atrium over a stiff wire via the created fenestration (arrowed); C: Deployment of the leadless pacemaker device from the femoral approach to the systemic left ventricle of a patient with an extracardiac Fontan (arrowed).
Figure 14 Transpulmonary puncture for leadless pacemaker insertion.
A: Transpulmonary puncture in a patient with left atrial isomerism, dextrocardia and Kawashima and Extracardiac Fontan repair; B: The final released position of the leadless pacemaker.
Figure 15 Retrograde aortic delivery of a leadless pacemaker via the left carotid artery.
Multiple abandoned pacing leads can be seen.
Figure 16 Leadless pacemakers in both the atrium and ventricle (starred) of a univentricular heart patient and an ablation catheter for an atrio-ventricular nodal ablation for atrial fibrillation rate control in the same sitting.
Collateral coils can be seen in multiple positions (arrowed).
- Citation: Papaioannou V, Jones J, Faraz F, Mayhew D, Rao A, Kahn M, Moharem-Elgamal S, Ashrafi R. Pacing in adults with complex congenital heart disease: A narrative minireview. World J Cardiol 2026; 18(11): 125622
- URL: https://www.wjgnet.com/1949-8462/full/v18/i11/125622.htm
- DOI: https://dx.doi.org/10.4330/wjc.125622