Retrospective Study
Copyright ©The Author(s) 2024.
World J Gastrointest Surg. Jul 27, 2024; 16(7): 2135-2144
Published online Jul 27, 2024. doi: 10.4240/wjgs.v16.i7.2135
Table 1 Comparison of diagnostic efficacy of magnetic resonance imaging and spiral computed tomography in T staging
Index
Pathological stage
T1
T2
T3
T4
MRI
    Sensitivity82.61 (19/23)73.91 (17/23)78.13 (25/32)76.47 (13/17)
    Specificity94.44 (68/72)87.50 (63/72)92.06 (58/63)96.15 (75/78)
    Accuracy91.58 (87/95)a84.21 (80/95) a87.37 (83/95)a92.63 (88/95)a
SCT
    Sensitivity78.26 (18/23)65.22(15/23) a62.50 (20/32)a52.94 (9/17)a
    Specificity91.67 (66/72)a86.11 (62/72)a82.54 (52/63)a92.31 (72/78)a
    Accuracy88.42 (84/95)a81.05 (77/95)a75.79 (72/95)a85.26 (81/95)a
MRI + SCT
    Sensitivity95.65 (22/23)95.65 (22/23)93.75 (30/32)94.12 (16/17)
    Specificity98.61(71/72)95.83 (69/72)98.41 (62/63)100.00 (78/78)
    Accuracy97.89 (93/95)95.79 (91/95)96.84 (92/95)98.95 (94/95)
Table 2 Comparison of diagnostic efficacy of magnetic resonance imaging and spiral computed tomography in N staging
Index
Pathological stage
N0
N1
N2
MRI
    Sensitivity74.36 (29/39)72.73 (16/22)73.53 (25/34)
    Specificity89.29 (50/56)80.82 (59/73)91.80 (56/61)
    Accuracy83.16 (79/95)77.95 (75/95)85.26 (81/95)
SCT
    Sensitivity61.54 (24/39)a68.18 (15/22)52.94 (18/34)a
    Specificity87.50 (49/56)67.12 (49/73)a88.52 (54/61)
    Accuracy76.84 (73/95)67.37 (64/95)a75.79 (72/95)a
MRI + SCT
    Sensitivity87.18 (34/39)81.81 (18/22)79.41 (27/34)
    Specificity94.64 (53/56)86.30 (63/73)95.08 (58/61)
    Accuracy91.58 (87/95)85.26 (81/95)89.69 (85/95)
Table 3 Comparison of diagnostic efficacy of magnetic resonance imaging and spiral computed tomography in M staging
Index
Pathological stage
M0
M1
MRI
    Sensitivity95.45 (42/44)98.04 (50/51)
    Specificity98.04 (50/51)95.45 (42/44)
    Accuracy96.84 (92/95)96.84 (92/95)
SCT
    Sensitivity93.18 (41/44)92.16 (47/51)a
    Specificity92.16 (47/51)93.18 (41/44)
    Accuracy92.63 (88/95)92.63 (88/95)a
MRI + SCT
    Sensitivity97.73 (43/44)100.00 (51/51)
    Specificity96.08 (49/51)97.73 (43/44)
    Accuracy96.84 (92/95)98.95 (94/95)
Table 4 Predictive value of magnetic resonance imaging and spiral computed tomography
Index
AUC
95%CI
Sensitivity
Specificity
P value
BV0.7500.612-0.8890.7140.7780.003
BF0.6830.559-0.8060.8570.5930.030
TTP0.7720.633-0.9100.6430.8020.001
PS0.7610.615-0.9060.6430.8400.002
Kep0.7090.538-0.8800.7860.6910.013
Ktrans0.7190.536-0.9020.7140.7530.009
Ve0.9100.825-0.9950.7860.914< 0.001