Sutkowska E, Marciniak D, Koszewicz M, Dziadkowiak E, Budrewicz S, Biernat K, Kuciel N, Mazurek J, Hap K. Validity and reliability of the Polish version of the Michigan Neuropathy Screening Instrument. World J Diabetes 2023; 14(4): 435-446 [PMID: 37122429 DOI: 10.4239/wjd.v14.i4.435]
Corresponding Author of This Article
Katarzyna Hap, Doctor, University Rehabilitation Centre, Wroclaw Medical University, Borowska Street 213, Wroclaw 50-556, Poland. katarzyna.hap@umw.edu.pl
Research Domain of This Article
Medicine, General & Internal
Article-Type of This Article
Observational Study
Open-Access Policy of This Article
This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
Table 2 Reliability results for the patient and practitioner sections of the Michigan Neuropathy Screening Instrument-Polish version
Part A of MNSI
Part B of MNSI
n = 80
Cronbach alpha, full scale: 0.81790
Cronbach alpha, full scale: 0.87095
Corr 1st & 2nd half: 0.745791
Corr 1st & 2nd half: 0.972206
Split-half reliability: 0.854388
Split-half reliability: 0.985907
Guttman split-half: 0.840785
Guttman split-half: 0.985838
Summary for A1
Summary for A2
Summary for B1
Summary for B2
Mean
4.250000
4.150000
6.212500
6.175000
Sum
340.0000
332.0000
497.0000
494.0000
SD
3.403275
4.313946
3.925553
3.860790
Variance
11.58228
18.61013
15.40997
14.90570
Cronbach alpha
0.6499672
0.7060083
0.7337023
0.7346509
Table 3 Stability of the patient and practitioner sections of the Michigan Neuropathy Screening Instrument-Polish version
Part of MNSI
Mean (SD)
ICC for agreement
ICC for consistency
Test score
Re-test score
ICCagreement
Pvalue
ICCconsistency
Pvalue
A
2.125 (1.70)
2.075 (2.16)
0.728
9.05E-15
0.725
9.47E-15
B
3.106 (1.96)
3.088 (1.93)
0.972
6.19E-52
0.972
8.53E-52
Table 4 The area under the curve values for Nerve Conduction Study and Michigan Neuropathy Screening Instrument Polish version (version A and B) at both time points
Variable
AUC
Pvalue
A1
0.749
0.0003
B1
0.796
0.0000
A2
0.617
0.2296
B2
0.770
0.0001
Table 5 The cut-off points for Michigan Neuropathy Screening Instrument Polish version at the two time points and their sensitivity and specificity, and their positive and negative predictive values based on receiver operating characteristic curves
Variable
True positives, n, %
False positives, n, %
False negatives, n, %
True negatives, n, %
Sensitivity
Specificity
Optimal cut-off point
A1
28/35
0/0
42/52.5
10/12.5
0.400
1.000
3
B1
57/71.25
3/3.75
13/16.25
7/8.75
0.814
0.700
2
A2
23/28.75
1/1.25
47/58.75
9/11.25
0.329
0.900
3
B2
59/73.75
4/5
11/13.75
6/7.5
0.843
0.600
2
Citation: Sutkowska E, Marciniak D, Koszewicz M, Dziadkowiak E, Budrewicz S, Biernat K, Kuciel N, Mazurek J, Hap K. Validity and reliability of the Polish version of the Michigan Neuropathy Screening Instrument. World J Diabetes 2023; 14(4): 435-446