Copyright
©The Author(s) 2015.
World J Gastrointest Endosc. Feb 16, 2015; 7(2): 87-93
Published online Feb 16, 2015. doi: 10.4253/wjge.v7.i2.87
Published online Feb 16, 2015. doi: 10.4253/wjge.v7.i2.87
Ref. | No. pts | Technique | Satisfactory outcome (%) | Overall morbidity (%) | Salivary fistula (%) |
Orringer[46] | 12 | M, DM | 85 | 25 | 8 |
Ellis et al[47] | 10 | DM | 100 | 0 | 0 |
Konowitz et al[48] | 20 | DM | 100 | 20 | 5 |
Barthlen et al[49] | 43 | M, DM | 82 | 7 | 0 |
Payne et al[7] | 888 | D | 93 | 30 | 1 |
Morton et al[50] | 15 | DM | 100 | 40 | 13 |
Bonafede et al[51] | 87 | D, DM, DpM | 78 | 24 | NA |
Fraczek et al[52] | 37 | DM, DpM | 93 | 23 | 5 |
Van Eeden et al[53] | 17 | M, DM, DpM | 59 | 6 | 14 |
Zbären et al[54] | 66 | DM | 77 | 15 | 12 |
Busaba et al[55] | 9 | DM | 100 | 0 | 0 |
Leporrier et al[56] | 40 | DM, DpM | 92 | 10 | 3 |
Sydow et al[57] | 13 | M, DM, DpM | NA | 27 | 23 |
Gutschow et al[58] | 101 | M, D, DM, DpM | 98 | 13 | 13 |
Zaninotto et al[59] | 34 | DM, M | 100 | 12 | 6 |
Colombo-Benkmann et al[60] | 79 | D, DM | 99 | 4 | 4 |
Bonavina et al[3] | 116 | DM | 94 | 0.8 | 0.8 |
Rizzetto et al[4] | 77 | DM, DpM, M | 95 | 13 | 4 |
Ref. | No. pts | Technique | Satisfactory outcome | Overall morbidity | Salivary fistula | Conversion rate |
Fremling et al[61] | 6 | Stapling | 100% | 0% | 0% | 0% |
Peracchia et al[36] | 95 | Stapling | 93% | 1% | 0% | 3% |
Narne et al[62] | 102 | Stapling | 100% | 0% | 0% | 4% |
Philippsen et al[15] | 14 | Stapling | 100% | 0% | 0% | 21% |
Cook et al[16] | 74 | Stapling | 97% | 3% | 2% | 8% |
Lüscher et al[63] | 23 | Stapling | 96% | 1% | 4% | 0% |
Jaramillo et al[64] | 32 | Stapling | 80% | 4% | 0% | 16% |
Thaler et al[65] | 23 | Stapling | 87% | 0% | 0% | 30% |
Counter et al[66] | 31 | Stapling | 95% | 10% | 10% | 0% |
Chang et al[22] | 24 | CO2 laser | 90% | 8% | 0% | 0% |
Fama et al[18] | 25 | Harmonic Scalpel | 96% | 12% | 0% | 0% |
Sharp et al[19] | 48 | Stapling/Harmonic Scalpel | 88% | 12% | 2% | 0% |
Helmstaedter et al[23] | 40 | CO2 laser | NA | 10% | NA | NA |
Wasserzug et al[67] | 55 | Stapling | 90% | 4% | 2% | 7% |
Peretti et al[68] | 28 | CO2 laser | 85% | 7% | 4% | 4% |
Nicholas et al[13] | 7 | Stapling | 100% | 14% | 0% | 0% |
May et al[20] | 7 | Harmonic Scalpel | 100% | 0% | 0% | 0% |
Bonavina et al[14] | 91 | Stapling | 80.8% | 5% | 1% | 13.2% |
Adam et al[69] | 128 | Stapling/CO2 laser | NA | 4.6% | 0% | NA |
Ref. | No. pts | Incision device | Accessories | Satisfactory outcome | Overall morbidity | Salivary fistula |
Mulder et al[25] | 20 | Coagulation | Forceps | NA | 0% | 0% |
Ishioka et al[24] | 42 | Needle Knife | Mix | 93% | 1% | 2% |
Hashiba et al[70] | 47 | Needle Knife | Mix | 96% | 2% | 13% |
Mulder[71] | 125 | Argon Plasma | None | 100% | 2% | 15% |
Sakai et al[28] | 10 | Needle Knife | Hood | 100% | 1% | 0% |
Costamagna et al[31] | 28 | Needle Knife | Cap | 43% | 14% | 18% |
Rabenstein et al[72] | 41 | Argon Plasma | Cap | 95% | 0% | 3% |
Christiaens et al[32] | 21 | Monopolar forceps | Hood | 100% | 0% | 5% |
Vogelsang et al[34] | 31 | Needle Knife | Cap | 84% | 3% | 23% |
Tang et al[35] | 6 | Needle Knife | Hood/Endoclips | 100% | 0% | 0% |
Case et al[73] | 22 | Needle Knife | Cap | 100% | 32% | 27% |
Repici et al[29] | 32 | Hook knife | None | 88% | 6% | 3% |
Al-Kadi et al[74] | 18 | Needle Knife | None | 78% | 12% | 6% |
Hondo et al[33] | 6 | Harmonic scalpel | Soft diverticuloscope | 100% | 0% | 0% |
- Citation: Aiolfi A, Scolari F, Saino G, Bonavina L. Current status of minimally invasive endoscopic management for Zenker diverticulum. World J Gastrointest Endosc 2015; 7(2): 87-93
- URL: https://www.wjgnet.com/1948-5190/full/v7/i2/87.htm
- DOI: https://dx.doi.org/10.4253/wjge.v7.i2.87