Review
Copyright ©The Author(s) 2015.
World J Gastrointest Endosc. Aug 25, 2015; 7(11): 1032-1038
Published online Aug 25, 2015. doi: 10.4253/wjge.v7.i11.1032
Table 1 The results of comparison between metallic and plastic stents
Ref.No. of patients
Successful deployment % (n)
P valuePatency (mo)
P value
MSPSMSPSMSPS
Sangchan et al[1]545483 (45/54)85 (46/54)0.7923.41.2> 0.001
Perdue et al[2]353397 (34/35)85 (28/33)NANA
Liberato et al[3]24923199 (246/249)88 (204/231)> 0.0016.34.7> 0.0001
Mukai et al[4]3030100 (30/30)100 (30/30)123.70.0002
Table 2 The results of comparison between unilateral and bilateral stent deployment
Ref.No. of patients
Successful deployment [% (n)]
P valueSuccessful drainage [% (n)]
P valueStent patency (mo)
P valueSurvival period (mo)
P value
UnilateralBilateralUnilateralBilateralUnilateralBilateralUnilateralBilateralUnilateralBilateral
De Palma et al[9]PS 79PS 7889 (70/79)77 (60/78)0.04181 (64/79)73 (57/78)0.0482NANA4.74.70.482
Mukai et al[4]PS 15PS 15100 (15/15)100 (15/15)100 (15/15)100 (15/15)3.43.70.746NANA
MS 14MS 16100 (14/14)100 (16/16)100 (14/14)100 (16/16)12.19.80.3467NANA
Liberato et al[3]PS 27PS 40NA95 (38/40)NA95 (38/40)4.04.20.0004NANA
MS 33MS 45NA93 (42/45)NA93 (42/45)5.66.8> 0.0001NANA
Chang et al[10]PS or MS 69PS or MS 29NANANANANANA2.77.5> 0.01
Naitoh et al[11]MS 17MS 29100 (17/17)90 (26/29)94 (16/17)90 (25/26)7.016.30.0095.56.80.559
Iwano et al[12]MS 63MS 1995 (60/63)90 (17/19)NANA4.44.20.32205.76.10.4908
Table 3 The results of comparison between stent-in stent and side-by-side method for deployment of bilateral metallic stents
Ref.Method for deploymentNo. of patientsSuccessful deployment % (n)Successful drainage % (n)Occlusion % (n)Stent patency (mo)
Kawamoto et al[16]SIS9100 (9/9)100 (9/9)33 (3/9)NA
Lee et al[17]SIS1080 (8/10)100 (8/8)25 (2/8)7.2
Park et al[18]SIS3594 (33/35)100 (33/33)6 (2/33)5
Kim et al[19]SIS3485 (29/34)100 (29/29)31 (9/29)6.2
Chahal et al[20]SIS21100 (21/21)NA38 (8/21)6.3
Kogure et al[21]SIS12100 (12/12)92 (11/12)50 (6/12)6.7
Hwang et al[22]SIS3087 (26/30)100 (26/26)39 (10/26)4.7
Lee et al[23]SIS8495 (80/84)93 (78/84)31 (24/78)7.9
Dumas et al[24]SBS4573 (33/45)100 (33/33)3 (1/33)NA
Cheng et al[25]SBS3697 (35/36)NA31 (11/35)5.6
Chennat et al[26]SBS16100 (16/16)75 (11/16)25 (4/16)4.3
Lee et al[27]SBS4491 (40/44)98 (39/40)45 (18/40)5.2
Table 4 The results of re-intervention after stent occlusion in the patients undergoing deployment of bilateral metallic stents
Ref.Method for deploymentNo. of patientsOcclusion% (n)Endoscopic re-intervention % (n)Bilateral or multiple drainage at endoscopic re-intervention % (n)
Naitoh et al[28]SIS2442 (10/24)90 (9/10)NA
SBS2520 (5/25)100 (5/5)NA
Lee et al[27]SBS4045 (18/40)92 (12/13)150 (6/12)
Fujii et al[33]SIS5555 (30/55)100 (30/30)67 (20/30)
Lee et al[23]SIS7831 (24/78)96 (23/24)83 (20/24)
Law et al[31]SBS1753 (9/17)75 (6/8)75 (6/8)
SIS743 (3/7)100 (3/3)100 (3/3)