Table 1 Published case reports of incarcerated colonoscopes in inguinal hernia and strategy utilized to remove the scope
Ref.No. of casesInguinal hernia (side)Method of scope removalDistance from anus at obstructionObstruction on insertion vs withdrawal
Waye[5]1UnknownNANANA
Leichtmann et al[6]3× 2 Unknown× 2 Manual reductionNANA
× 1 Known× 1 Hernial reduction before and maintenance during procedure
Fulp et al[7]1Known,Withdrawl of endoscopeSigmoid colonInsertion
Left
Leisser et al[8]1Unknown, LeftManual reduction60 cmInsertion
Koltun et al[1]2Known,Failed fluoroscopic reductionNAWithdrawal
RightManual reduction utilizing “Pulley” technique
Yamamoto et al[4]1Unknown,Failed manual reduction, Reduction under fluoroscopic guidance70cmInsertion
Left
Saunder[9]1UnknownNANANA
Punnam et al[10]1KnownFailed manual reductionNAWithdrawal
LeftSurgical Dissection of Hernial Sac
Lee et al[2]1Unknown, LeftManual reductionNAInsertion
Iser et al[11]1Unknown,Manual reduction under deep sedationNANA
Left
Fan et al[3]1Unknown,Reduction under fluoroscopy and external manual pressure60 cmWithdrawal
Left
Kume et al[12]1Unknown,Reduction under fluoroscopy60 cmWithdrawal
Left