Table 1 Second generation contrast agents currently available
| Contrast agent | Shell components | Gas | Mechanical index |
| Definity® | Phospholipid | Perfluoropropane | Low |
| Imagent® | Phospholipid | Perfluorohexane | Low |
| SonoVue® | Phospholipid | Sulfur hexafluoride | Low |
| Sonavist® | Polymer | Sulfur hexafluoride | Low |
| Sonazoid® | Lipid | Perfluorocarbon | Low |
| Optison® | Albumin | Perfluoropropane | Low |
| Sonogen® | Surfactant | Perfluoropentane | Low |
| Levovist® | Galactose/Palmitic acid | Air | High |
| Albunex® | Albumin | Air | High |
Table 2 Effect of mechanical index on second generation microbubbles
| Mechanical index | Effect on microbubble oscillation | Relationship between emitted sound waves and detected signal |
| Low (< 0.1) | Symmetrical | Linear |
| Moderate (0.1-0.6) | Asymmetrical | Non-linear |
| High (> 0.6) | Destruction | N/A |
Table 3 Accuracy of contrast enhanced endoscopic ultrasound versus other imaging modalities
- Citation: Mohamed RM, Yan BM. Contrast enhanced endoscopic ultrasound: More than just a fancy Doppler. World J Gastrointest Endosc 2010; 2(7): 237-243
- URL: https://www.wjgnet.com/1948-5190/full/v2/i7/237.htm