Copyright
©The Author(s) 2022.
World J Gastrointest Endosc. Nov 16, 2022; 14(11): 694-703
Published online Nov 16, 2022. doi: 10.4253/wjge.v14.i11.694
Published online Nov 16, 2022. doi: 10.4253/wjge.v14.i11.694
Table 1 Characteristics of the study subjects
Characteristics | |
n | 12259 |
Age, mean (SD), yr | 53.6 (12.2) |
Male sex, % | 50.7 |
Looping, none/mild/severe, n | 5532/4399/2253 |
Insertion time, mean (SD), min | 4.57 (2.66) |
Withdrawal time, mean (SD), min | 13.87 (4.19) |
Experienced endoscopist, % | 70.4 |
Polyp detection | |
Adenoma DR, % | 44.7 |
Advanced adenoma DR, % | 2.0 |
High-risk adenoma DR, % | 9.9 |
CSSP DR, % | 8.9 |
SSL DR, % | 3.5 |
Number of adenomas, mean (SD), n | 0.82 (1.25) |
Number of SSLs, mean (SD), n | 0.04 (0.24) |
Table 2 Subject characteristics based on looping severity
No looping | Mild looping | Severe looping | P value | |
n | 5532 | 4399 | 2253 | |
Age, mean (SD), yr | 51.5 (11.5) | 54.2 (12.2) | 56.7 (13.0) | < 0.001 |
Male sex, % | 62.8 | 44.6 | 33.4 | < 0.001 |
Insertion time, mean (SD), min | 3.53 (1.89) | 4.95 (2.41) | 6.38 (3.44) | < 0.001 |
Withdrawal time, mean (SD), min | 13.70 (4.30) | 14.17 (4.29) | 13.74 (3.66) | < 0.0011 |
Experienced endoscopist, % | 61.1 | 73.7 | 87.6 | < 0.001 |
Polyp detection | ||||
Adenoma DR, % | 42.2 | 45.0 | 50.2 | < 0.001 |
Advanced adenoma DR, % | 1.8 | 2.1 | 2.3 | 0.166 |
High-risk adenoma DR, % | 8.4 | 9.8 | 13.5 | < 0.001 |
CSSP DR, % | 7.8 | 9.5 | 10.3 | < 0.001 |
SSL DR, % | 3.2 | 3.7 | 3.9 | 0.064 |
Number of adenomas, mean (SD), n | 0.74 (1.16) | 0.81 (1.25) | 1.03 (1.44) | < 0.001 |
Number of SSLs, mean (SD), n | 0.04 (0.22) | 0.05 (0.26) | 0.05 (0.26) | 0.553 |
Table 3 Multivariate analysis of the effect on polyp detections
Odds ratio | 95% confidence interval | DOF | P value | |
Adenoma | ||||
Looping1 | 1.13 | 1.06-1.20 | 1 | < 0.001 |
Age | 1.05 | 1.04-1.05 | 1 | < 0.001 |
Male sex | 1.39 | 1.28-1.50 | 1 | < 0.001 |
Insertion time | 0.94 | 0.92-0.96 | 1 | < 0.001 |
Withdrawal time | 1.14 | 1.13-1.15 | 1 | < 0.001 |
Endoscopist experience | 1.68 | 1.53-1.85 | 1 | < 0.001 |
High-risk adenoma | ||||
Looping1 | 1.25 | 1.13-1.38 | 1 | < 0.001 |
Age | 1.05 | 1.05-1.06 | 1 | < 0.001 |
Male sex | 1.527 | 1.33-1.74 | 1 | < 0.001 |
Insertion time | 0.90 | 0.87-0.93 | 1 | < 0.001 |
Withdrawal time | 1.20 | 1.18-1.21 | 1 | < 0.001 |
Endoscopist experience | 3.91 | 3.17-4.82 | 1 | < 0.001 |
Clinically significant serrated polyp | ||||
Looping1 | 1.14 | 1.04-1.26 | 1 | 0.007 |
Age | 1.00 | 0.99-1.01 | 1 | 0.999 |
Male sex | 0.60 | 0.52-0.68 | 1 | < 0.001 |
Insertion time | 0.92 | 0.88-0.95 | 1 | < 0.001 |
Withdrawal time | 1.16 | 1.14-1.17 | 1 | < 0.001 |
Endoscopist experience | 2.04 | 1.71-2.43 | 1 | < 0.001 |
Table 4 Multivariate analysis of the effect on polyp detections in the sub-analysis of experienced endoscopists
Odds ratio | 95% confidence interval | DOF | P value | |
Adenoma | ||||
Looping1 | 1.14 | 1.07-1.23 | 1 | < 0.001 |
Age | 1.05 | 1.05-1.05 | 1 | < 0.001 |
Male sex | 1.42 | 1.29-1.56 | 1 | < 0.001 |
Insertion time | 0.93 | 0.91-0.95 | 1 | < 0.001 |
Withdrawal time | 1.13 | 1.11-1.14 | 1 | < 0.001 |
High-risk adenoma | ||||
Looping1 | 1.27 | 1.14-1.41 | 1 | < 0.001 |
Age | 1.05 | 1.05-1.06 | 1 | < 0.001 |
Male sex | 1.56 | 1.35-1.81 | 1 | < 0.001 |
Insertion time | 0.89 | 0.85-0.92 | 1 | < 0.001 |
Withdrawal time | 1.18 | 1.16-1.20 | 1 | < 0.001 |
Clinically significant serrated polyp | ||||
Looping1 | 1.15 | 1.04-1.28 | 1 | 0.008 |
Age | 1.00 | 1.00-1.01 | 1 | 0.627 |
Male sex | 0.66 | 0.57-0.77 | 1 | < 0.001 |
Insertion time | 0.92 | 0.89-0.96 | 1 | < 0.001 |
Withdrawal time | 1.13 | 1.11-1.15 | 1 | < 0.001 |
- Citation: Toyoshima O, Nishizawa T, Yoshida S, Matsuno T, Arano T, Kondo R, Kinoshita K, Yasumi Y, Tsuji Y, Fujishiro M. Impact of looping on premalignant polyp detection during colonoscopy. World J Gastrointest Endosc 2022; 14(11): 694-703
- URL: https://www.wjgnet.com/1948-5190/full/v14/i11/694.htm
- DOI: https://dx.doi.org/10.4253/wjge.v14.i11.694