Enteroscope device | ||||
Entire cohort | Retrograde SBE1 | Retrograde TTSE2 | ||
Number of patients | 75 | 49 | 26 | |
Mean (standard deviation) | Mean (standard deviation) | Mean (standard deviation) | P value | |
Age (yr)3 | 61.2 (17.6) | 62.6 (16.5) | 58.4 (19.6) | 0.33 |
Body mass index3 | 29.0 (6.1) | 28.7 (6.3) | 29.6 (5.9) | 0.55 |
Gender, n (%) | 0.63 | |||
Female | 43 (57.3) | 27 (55.1) | 16 (61.5) | |
Male | 32 (42.7) | 22 (44.9) | 10 (38.5) | |
Ethnicity, n (%) | 0.91 | |||
Hispanic | 27 (36.0) | 18 (36.7) | 9 (34.6) | |
Other non-hispanic | 10 (13.3) | 7 (14.3) | 3 (11.5) | |
White | 38 (50.7) | 24 (49.0) | 14 (53.9) | |
Indication3 | 0.63 | |||
Iron deficiency anemia, n (%) | 41 (50.6) | 28 (51.9) | 13 (48.2) | |
Overt GI bleeding | 37 (45.7) | 23 (42.6) | 14 (51.9) | |
Abdominal pain | 17 (21.1) | 7 (13.0) | 10 (37.0) | |
Diarrhea | 7 (8.6) | 4 (7.4) | 3 (11.1) | |
FAP screening | 2 (2.5) | 2 (3.7) | 0 (0) |
Enteroscope device | ||||
Entire cohort | Retrograde SBE1 | Retrograde TTSE2 | ||
Number of procedures | 81 | 54 | 27 | |
Mean (SD) | Mean (SD) | Mean (SD) | P value3 | |
Duration of procedure | 86.2 (34.2) | 91.9 (34.2) | 70.5 (30.7) | 0.04 |
Depth of the scope insertion | 82.1 (64.1) | 92.5 (70.0) | 64.6 (49.0) | 0.08 |
Successful procedure with diagnostic yield, n (%) | n = 64 | n = 41 | n = 23 | 0.39 |
Normal | 43 (67.2) | 26 (63.4) | 17 (73.9) | |
Positive finding | 21 (32.8) | 15 (36.6) | 6 (26.1) | |
Intervention performed, n (%) | 0.38 | |||
No | 65 (80.3) | 45 (83.3) | 20 (74.1) | |
Yes | 16 (19.8) | 9 (16.7) | 7 (25.9) | |
Failed (2011-2018), n (%) | 17 (21.0) | 13 (24.1) | 4 (14.8) | 0.33 |
Terminal ileum not intubated | 9 (11.1) | 8 (14.8) | 1 (3.7) | |
Insertion < 20 cm | 8 (9.9) | 5 (9.3) | 3 (11.1) | |
Years | Failed/procedure | Failed/procedure | Failed/procedure | |
2011-2012 | 5/14 | 5/14 | - | |
2013-2014 | 4/27 | 4/22 | 0/5 | |
2015-2016 | 6/26 | 3/11 | 3/15 | |
2017-2018 | 2/14 | 1/7 | 1/7 |